equipments for fgss & me-gi engines flyer fgss system rev0.pdf · equipments for fgss &...
TRANSCRIPT
TECNOCRYO
EQ
UIP
MEN
TS F
OR F
GSS
& M
E-G
I EN
GIN
ES
EQUIPMENTS FOR FUEL GAS SUPPLY SYSTEMEQUIPMENTS FOR FUEL GAS SUPPLY SYSTEMEQUIPMENTS FOR FUEL GAS SUPPLY SYSTEMEQUIPMENTS FOR FUEL GAS SUPPLY SYSTEM
Equipments, components and skid modules for the Fuel Gas Supply System
(FGSS) to dispach the LNG into CNG to the new generation of ME.GI. Engines
for ships:
Tecnocryo partnership for the capability of:
- Full Mechanical Design and Engineering
- Equipments definition
- All-in-one skid modules
- Product Reliability and Quality
Equipments:
- LNG High pressure pump skids (ME.GI. Skid type)
- LNG Vaporizing skids (HTF Skid type)
- LNG Vaporizers (CWX Exchanger type)
TH
E C
OM
PA
NY O
F
CRYO
GEN
IC G
AS
Tecnocryo S.p.A.
Via Ugo Foscolo 8
20060 Basiano (MI)
Italy
phone: +39.02957641.20
fax: +39.02957641.02
web site: http://www.tecnocryo.com/
e-mail: [email protected]
LNG HIGH PRESSURE PUMP SKID (ME.GI SKID)LNG HIGH PRESSURE PUMP SKID (ME.GI SKID)LNG HIGH PRESSURE PUMP SKID (ME.GI SKID)LNG HIGH PRESSURE PUMP SKID (ME.GI SKID)
Double Cryogenic Pumps skid
Full Mechanical Design
Compactness
Enanched Lifetime
Reliability
Quality
Rules for Ships of any Class or Register
Design
Manufacturing
Installation
Assembly
Testing
Inspection
All in Tecnocryo’s
premises.
Skids delivered
certified by Class for
Ship installation.
Control
cabinet
LNG Cryo
Pump Triplex
Electric motor
GearBox transmission
Mobile
baseframe
Drip tray
For leaks
Pulsation
dampener
Cryo-Piping
For LNG
Quality
TH
E C
OM
PA
NY O
F
CRYO
GEN
IC G
AS
Tecnocryo S.p.A.
Via Ugo Foscolo 8
20060 Basiano (MI)
Italy
phone: +39.02957641.20
fax: +39.02957641.02
web site: http://www.tecnocryo.com/
e-mail: [email protected]
Medium LNG
Flow up to 6200 kg/h (per pump)
Pressure up to 370 barg
Temperature -196°C / +65°C
Power lower than 200 kW (per pump)
Pump speed lower than 340 rpm for long life
Hydraulic eff. More than 85 %
Transmission Lubricated gearbox for long life
Performance
Single Cryogenic Pumps skid
Mobile
baseframe
Cryogenic
pump
Pulsation
dampener
Electric
motor Belts
Transmission
Drip
tray Cryogenic
piping
TH
E C
OM
PA
NY O
F
CRYO
GEN
IC G
AS
Tecnocryo S.p.A.
Via Ugo Foscolo 8
20060 Basiano (MI)
Italy
phone: +39.02957641.20
fax: +39.02957641.02
web site: http://www.tecnocryo.com/
e-mail: [email protected]
Medium LNG
Flow up to 1900 kg/h (per pump)
Pressure up to 420 barg
Temperature -196°C / +65°C
Power lower than 90 kW (per pump)
Pump speed lower than 450 rpm
Hydraulic eff. More than 85 %
Transmission Pulley with timing-belts for easy maintenance
Performance
TH
E C
OM
PA
NY O
F
CRYO
GEN
IC G
AS
Tecnocryo S.p.A.
Via Ugo Foscolo 8
20060 Basiano (MI)
Italy
phone: +39.02957641.20
fax: +39.02957641.02
web site: http://www.tecnocryo.com/
e-mail: [email protected]
LNG LNG LNG LNG VAPORIZER SKIDVAPORIZER SKIDVAPORIZER SKIDVAPORIZER SKID ((((HTFHTFHTFHTF SKID)SKID)SKID)SKID)
LNG Vaporizing Skid (HTF Skid type)
Full Mechanical Design
Compactness
Enanched Lifetime
Reliability
Quality
Rules for Ships of any Class or Register
Design
Manufacturing
Installation
Assembly
Testing
Inspection
All in Tecnocryo’s premises.
Skids delivered certified by Class for Ship installation.
Suction
manifold
Hot Water
heater
loop
Delivery
manifold
Mobile baseframe
Glycol-Water Pump (2)
Drum tank
Water-Glycol
Vaporizer
CWX Type
Quality
Tecnocryo S.p.A.
Via Ugo Foscolo 8
20060 Basiano (MI)
Italy
phone: +39.02957641.20
fax: +39.02957641.02
web site: http://www.tecnocryo.com/
e-mail: [email protected]
Medium LNG to CNG
Glycol-water loop for the LNG vaporization
Hot water as the heat source
Flow LNG up to 6200 kg/h
W-Glycol from 60 to 130 m3/h upon temperature difference
Hot water from 40 to 60 m3/h upon temperature difference
Pressure design at 10 barg for water-glycol and hot water
Temperature between 55°C and 80°C
Power lower than 20 kW (per pump)
Overall size 3m x 3.5 m, height 3.2 m
Performance
TH
E C
OM
PA
NY O
F
CRYO
GEN
IC G
AS
Tecnocryo S.p.A.
Via Ugo Foscolo 8
20060 Basiano (MI)
Italy
phone: +39.02957641.20
fax: +39.02957641.02
web site: http://www.tecnocryo.com/
e-mail: [email protected]
LNG VAPORIZER (CWX EXCHANGER TYPE)LNG VAPORIZER (CWX EXCHANGER TYPE)LNG VAPORIZER (CWX EXCHANGER TYPE)LNG VAPORIZER (CWX EXCHANGER TYPE)
CWX Vaporizer (Coil Wound Heat Exchanger)
Full Mechanical Design
Compactness
Enanched Lifetime
Reliability
Quality
Rules for Ships of any Class or Register
Medium LNG vaporized into CNG
Flow up to 6200 kg/h
Pressure up to 370 barg, up to 420 barg for some model
Temperature -196°C / +65°C
Inlet temp. -155°C +/- 5°C
Outlet temp. 45°C +/- 5°C
Performance Tube Side
Tube Side (LNG to CNG)
Shell Side
(Water-Glycol)
Nozzle for rupture disk
Body flange for maintenance
Water-Glycol outlet
Water-Glycol inlet
CNG outlet
(vaporized gas)
LNG inlet
(from pump)
Tecnocryo S.p.A.
Via Ugo Foscolo 8
20060 Basiano (MI)
Italy
phone: +39.02957641.20
fax: +39.02957641.02
web site: http://www.tecnocryo.com/
e-mail: [email protected]
Medium Water or Water-Glycol
Flow from 60 to 130 m3/h upon temperature difference
Pressure design at 10 barg
Temperature -20°C / + 90°C
Inlet temp. between 70°C and 80°C
Outlet temp. between 55°C and 65°C
Overall size Ø550, height 2.8 m
Performance Shell Side
Cryogenic Stabilization at -196°C With Liquid Nitrogen