era of intelligent power deliverypwrsocevents.com/wp-content/uploads/2012-presentations... ·...

20
© 2012, Intel Corporation Intel and the Intel logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Other names and brands may be claimed as the property of others. All products, dates, and figures are preliminary and are subject to change without any notice. Era of Intelligent Power Delivery Mandy Pant & Bill Bowhill Nov 2012

Upload: others

Post on 23-Jun-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

© 2012, Intel Corporation Intel and the Intel logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in

the United States and other countries. Other names and brands may be claimed as the property of others. All products, dates, and figures are preliminary and are subject to change without any notice.

Era of Intelligent Power Delivery

Mandy Pant

& Bill Bowhill

Nov 2012

Page 2: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

2

Power Delivery Today Current Trends Challenging Power Delivery Opportunities Summary

Outline

Page 3: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

3

“Big Iron Solutions” – Platform level VR power delivery

– VR on motherboard with switching FETs, inductors to reduce ripple and capacitors to control droop, low resistance path to socket and minimal communication with load die

– Metal Interconnect layers – Top level metal layers dedicated to power – Dedicated power and ground tracks on every metal layer

– On-die device decap – Decap placement opportunistic/focused budgeting in I/O

– Capacitors – Several arrays of capacitors on the motherboard and

package

Power Delivery Today

All on

Platform

Page 4: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

4

Mitigation of non-ideal power delivery

– Load Line – Outcome of power delivery impedance – Triple operating voltage constraints

– Idle (Imin) conditions: Top of loadline – Power Virus (Imax) conditions: Bottom of loadline – TDP conditions: somewhere along loadline

– Active Voltage Positioning (AVP) to minimize power impact on load – Associated with 3rd droop

– System exposed to “Excess” first droop

– Droop mitigation mechanisms – AFS – DAF

Power Delivery Today

First Droop

Second Droop

Third Droop

Page 5: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

5

Hit Power Wall – Increasing performance while operating within

Power limits

Response to power wall Dynamic power = a.f* C *V2* f – Decreased Cdyn, lowered V and slowed chip

down – Used clock-gating to reduce AF – Focused on Pipelined optimizations so all

circuits run at ideal V/F – balanced pipeline Note: continued lowering of V without improving power delivery can negate gains

P (Performance)-states – P-states enabled CPU cores to move along the

V/F curve for optimizing power efficency

Power Delivery Today

Page 6: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

6

Response to power wall – TM1/TM2

– Thermal solutions driving initial challenges

– Multiple cores – Multiple voltage domains – Die level Power gates which

enabled dynamic ON/OFF

Power Delivery Today Singl

e

Core

Dual

Die

Dual

Core

Multi

Core

Many

Core

Graphics

Core LLC

Core

Core LLC

Core LLC

System

Agent Display

DMI PCI Express

IMC

LLC

Power-gating on Intel’s SandyBridge processor

Core proliferation

Page 7: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

7

Local VRs, more VRs and per core pair VID

– Availability of Ararat on Poulson

– Enables power and performance optimization in light of increased variation

– Ref: New Itanium for 32nm and Beyond (MPR report March 2011)

Power Delivery Today Heatsink

Ararat

PSN part

Platform mother board

Chassis

Page 8: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

8

Some technology trends – Transistor density – Current density – Iccmax – Iccstep – Vmin – Vmax – Bump pitch scaling : slow – Die size – Metal stack – Interconnect wire width

Current Trends Challenging Power Delivery

Page 9: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

9

Increasing core count for microprocessors at power limited scaling

– Maximizing throughput under power budget increasing number of cores

– Close to Vmin operation for Power efficiency

– Increased sensitivity to droop

– % of chip power reserved for cores increasing

Current Trends Challenging Power Delivery

Tulsa

Tigerton

Dunnington

Nehalam-EX

Westmere-EX

2

4

6

8

10

Page 10: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

10

New core vectorized instructions for performance improvement: – Suitable for floating point-intensive calculations in multimedia, scientific and financial

applications (integer operations expected in later extensions) – Increases parallelism and throughput in floating point SIMD calculations – Reduces register load due to the non-destructive instructions

Current Trends Challenging Power Delivery

Traditionally ~15% gain/year

Nehalem

Scalable perf. & excellent power efficiency through wide vectorization, ISA extensions

High performance extensions

Future Performance Extensions

Page 11: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

11

Turbo 1.0 and Turbo 2.0 for opportunistic performance improvement

Current Trends Challenging Power Delivery

Core 0

Fre

qu

en

cy (

F)

Core 1 Core 2 Core 3

Fre

qu

en

cy (

F)

Core 0 Core 1 Core 2 Core 3

P1 .

.

.

.

.

.

.

Pn

P0

P1 .

.

.

.

.

.

.

Pn

TDP TDP TDP TDP

Pn = P-states where P0 ≥ P1 ≥ Pn Pn = P-states where P0 ≥ P1 ≥ Pn ;

“Opportunistic”

Frequency

Marked

Frequency

Fre

qu

en

cy (

F)

Core 0 Core 1 Core 2 Core 3

P0

P1 .

.

.

.

.

.

.

Pn

Page 12: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

12

Dynamic range of core increasing due to

– Vectorized instructions – Turbo

% of chip subject to

dynamic swings increasing dramatically due to

– Vectorized instructions – Turbo – increased number of cores

Current Trends Challenging Power Delivery

0

1

2

Classic Power gated Perf focused Turbo

Idle

TDP

Power Virus

Peak

Page 13: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

13

Voltage domain proliferation to minimize power consumption

– Dividing up power delivery resources to independently service each domain

– Need for adequate decoupling for each domain

– Leading to multiple clocking domains – Boundary latency issues – Requirement for increased circuitry

– low power and variation-robust

Current Trends Challenging Power Delivery

8 core Intel PSN IPF microprocessor with 10+ voltage domains

Page 14: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

14

Improved User Experience – Requirement for AOAC – Extended battery life on mobile

devices – Low leakage critical

– CPU cores needs to turn on and respond to changing workloads seamlessly

Current Trends Challenging Power Delivery

Page 15: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

15

Develop fine-grained and efficient on-the-fly power delivery solutions

– Elimination of VR stages between source and point of consumption to improve response time and reduce losses

– Increased integration of efficient low cost VR solutions to reduce droop

– LDOs, SCVRs etc

Opportunities

Sample LDO

Sample SCVR

Page 16: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

16

Develop fine-grained and efficient on-the-fly power delivery solutions

– Active and sophisticated control systems that respond rapidly to current demands

– High density die decoupling solutions

– Deliver smooth and high fidelity power with minimal noise as voltage domains are power up and down

Opportunities

Sample Metal-Insulator-Metal cap

ILD

TE

MIM ILD

ILD

BE

Vcc

Via

Vss

Via

Metal

layer

Metal

Layer

Page 17: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

17

Droop monitors to track and understand impact of droop

– Droop detectors – Droop inducers Ref: ITC-2009 “ Voltage Transient Detection and Induction for Debug and Test”

Opportunities

Inducer Current

Supply Voltage

Clock

on Tukwila

(Intel’s IPF)

Droop inducers being used to mitigate droop on Tukwila (Intel’s 65nm IPF )

Page 18: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

18

Enhanced architectural solutions to proactively control and reduce high frequency droops

– Instruction reordering – Instruction throttling

Simulation strategies to accurately predict

behavior in pre-Si – CAD tools to support capacity and efficiency – Emphasis on Package-die co-design/simulation

Opportunities

First Droop

Second Droop

Third Droop

Page 19: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

19

Entered era of bringing in intelligence to the power delivery system Look at increased integration of VRs to

seamlessly support active and changing current demands on the chip

Power management power delivery solution interactions

Solutions to understand and alleviate – Impact of increased Cdyn range due to new

instructions, higher performance cores, SIMD Creation of testbenches & tools to project

and understand impact of degraded power delivery in pre-Si

Summary

Lots of opportunities ahead!

Page 20: Era of Intelligent Power Deliverypwrsocevents.com/wp-content/uploads/2012-presentations... · 2015-12-17 · Voltage domain proliferation to minimize power consumption – Dividing

20

BACKUP