Page 1: Evan & Ryan Contractors | Evan & Ryan Contractors
Page 2: Evan & Ryan Contractors | Evan & Ryan Contractors
Page 3: Evan & Ryan Contractors | Evan & Ryan Contractors
Page 4: Evan & Ryan Contractors | Evan & Ryan Contractors

CHARGING VALVE

SIGHT GLASS

FILTER-DRYER

BARE PIPE IN COVER

RADIATION COVER ONLY

FINNED TUBE RADIATION

FINNED TUBE RADIATION IN COVER

THERMOSTATIC EXPANSION VALVE

EVAPORATOR PRESSURE REGULATOR

MANUAL REFRIGERATION VALVE

STRAINER

FLANGED CONNECTION

SIAMESE HOSE CONNECTION

PIPE ANCHOR

EXPANSION JOINT

PIPE ALIGNMENT GUIDES

UNION

END CAP

CONCENTRIC REDUCER

TEE DOWN

TEE UP

ELBOW DOWN

ELBOW UP

TEMPERATURE SENSOR

HUMIDISTAT

DUCT THERMOSTAT (ELECTRIC)

ROOM THERMOSTAT (HEAT/COOL)

ROOM THERMOSTAT (COOL)

DUCT THERMOSTAT (PNEUMATIC)

FLOW METER

MOTORIZED DAMPER

DIFFERENTIAL PRESSURE TRANSMITTER

ROOM THERMOSTAT (HEAT)

SAFETY/PRESSURE RELIEF VALVE

FLOW CONTROL VALVE

MAKEUP WATER VALVE

PRESSURE REDUCING VALVE

CHECK VALVE

BALANCING VALVE

VERTICAL SHUT-OFF/IN VERTICAL PIPE

SHUT-OFF VALVE

SHOCK ABSORBER

AIR CHAMBER

(DOWN IN ARROW DIRECTION)PIPE PITCH ARROW

PRESSURE GAUGE

AUTOMATIC AIR VENT

COMPOUND GAUGE

FLEX CONNECTOR

CONDENSER WATER RETURN

GROUND LOOP WATER RETURN

REFRIGERANT DISCHARGE

REFRIGERANT SUCTION

REFRIGERANT LIQUID

CONDENSER WATER SUPPLY

CHILLED WATER SUPPLY

CHILLED WATER RETURN

GROUND LOOP WATER SUPPLY

PENDANT SPRINKLER HEAD

UPRIGHT SPRINKLER HEAD

FIRE PROTECTION PIPING

POST INDICATOR VALVE

FIRE HYDRANT

FUEL OIL RETURN

FUEL OIL SUPPLY

INVERTED BUCKET TRAP

FLOAT & THERMOSTATIC TRAP

HEATING WATER RETURN

HEATING WATER SUPPLY

LOW PRESSURE CONDENSATE RETURN

LOW PRESSURE STEAM

RETURN OR EXHAUST DUCT DOWN

RETURN OR EXHAUST DUCT UP

FIRE DAMPER (FD) IN DUCT

SUPPLY DUCT DOWN

VOLUME DAMPER

SUPPLY DUCT UP

FUEL OIL VENT

FLOW ARROW

TEMP/PRESSURE RELIEF VALVE

CONCEALED SPRINKLER HEAD

DRY STANDPIPE

DRY PIPE SPRINKLER PIPING

PRE-ACTION SPRINKLER PIPING

ELBOW

TEE

CLEANOUTS

FLOOR DRAIN

STORM WATER (SUSPENDED)

TEMPERED WATER

GAS

DRAIN LINE

SANITARY WASTE (SUSPENDED)

SANITARY WASTE (BURIED)

SANITARY VENT LINE

STORM WATER (BURIED)

COLD SOFT WATER

HOT WATER (180° F)

HOT WATER RETURN (140° F)

HOT WATER (140° F)

HOT WATER RETURN

HOT WATER

140°

GAS METER

WATER METER

TAMPER SWITCH

FLOW SWITCH

PIPE SLEEVE

HOT SOFT WATER

HOT SOFT WATER RETURN

CONTROL VALVE (TCV)

3-WAY CONTROL VALVE

WET FIRE PROTECTION PIPING

REFRIGERANT HOT GAS

HOT WATER RETURN (180° F)

MEDIUM PRESSURE STEAM

HIGH PRESSURE STEAM

MEDIUM PRESSURE CONDENSATE RETURN

HIGH PRESSURE CONDENSATE RETURN

THERMOSTATIC TRAP

THROTTLING VALVE

PETE'S PLUG

FD

CARBON DIOXIDE SENSOR

VARIABLE FREQUENCY DRIVE

TEMPERATURE CONTROL PANEL

ACCESS PANEL

BOILER FEED WATER

EMERGENCY BOILER FEED WATER

COLD WATER

140°

180°

180°

T

CSW

HSW

HSWR

NON-POTABLE WATERNPW

G

AIR (WITH PSI)A

D

GM

WM

RPBPRPZ

(REDUCED PRESSUREBACKFLOW PREVENTER)

CS

CR

CHWS

CHWR

GS

GR

{

HS

HR

FOS

FOR

FOV

RD

RS

RL

RHG

DUAL TEMPERATURE SUPPLYDTS

DUAL TEMPERATURE RETURNDTR

BFW

EBFW

LPS

MPS

HPS

LPR

MPR

HPR

CONDENSATE PUMP DISCHARGEPD

CONDENSATE RETURNCR

F&T

IB

T

ECCENTRICAL REDUCER

CO

FD

D

F

DS

DP

PA

WP

PIV

TS

FS

COMBINATION FIRE/SMOKE DAMPER(FSD) IN DUCT

FSD

SD

SMOKE DAMPER (SD) IN DUCT

AP

INTERNAL LINED DUCT

CO2

FLOW SWITCHFS

FM

DPT

M

VFD

TCP

WELL WATERWW

8"E.

DENOTEDEXISTINGWORK

CONNECTIONTO EXISTING

SECTION OR ELEVATIONNUMBER

THERMOMETERT

S

TH

TH,C

TC

T

TE

H

T

DENOTEDNEW WORK

SIZE OFPIPE ORDUCT

DENOTEDEXISTING

SHEET NUMBER OFSECTION OR ELEVATION

DETAIL (LETTER)

SHEET NUMBER OFDETAIL LOCATION

ADAFCAFFAHRAHUALTAPAS

BDBDDBTUBV

CBCICLCOCONDCONVCUHCW

DBDFDIADIFFDSDXC

EAEATEBBRECEGECONVECUHEFELECELEVEOMEPUHERERCPESPEWCEWHEXPTE.

FDFPVAVFOBFSDFTR

GCGEN

HBHTGHWHWRHYD

IDINV. EL.

LATLAV

MBHMECHMHMCMSMUV

NCNO

OAOADOBDODORDOSD

PFHXPIVPLBGPRVPUH

RARADRCPRCNPRDRECIRCRGRPZRRRIVRRV

SASANSDSGSHDRSKSRSSSTHX

TCCTCPTGTOTPTYP

UR

VAVVCPVFDVSVSDVTR

WWBWCWS

ABBREVIATIONSTEMPERATURE CONTROL/MONITORING

DRAWING NOTATIONS

SECTIONS AND DETAILS

RADIATION SYMBOLS

DUCT SYMBOLS

FIRE PROTECTION SYSTEM

STEAM PIPING

HVAC PIPING

VALVES

REFRIGERATION VALVES/FITTINGS

PLUMBING

PIPE FITTINGS

GENERAL NOTES1. ALL NEW WORK IS DRAWN DARK. ALL WORK DRAWN LIGHT AND FOLLOWED

BY (E.) IS EXISTING. ALL WORK SHALL REMAIN UNLESS SPECIFICALLYNOTED OTHERWISE.

2. THESE NOTES APPLY TO EACH AND EVERY 'M' AND 'FP' SERIES DRAWINGS.

3. FIELD VERIFY ALL EXISTING CONDITIONS AS TO EXACT SERVICE, LOCATION,TYPE OF MATERIAL, ETC. BEFORE BIDDING AND BEFORE BEGINNINGRENOVATION WORK.

4. COORDINATE ALL SHUT-DOWNS, DELIVERY, AND STORAGE OF MATERIALS,ETC. WITH OWNER'S REPRESENTATIVE.

5. CONTRACTORS SHALL PROTECT ALL EXISTING OWNER FACILITIES DURINGCONSTRUCTION. ANY AND ALL OWNER FACILITIES DAMAGED ORDISCONNECTED BY CONTRACTOR OPERATIONS SHALL BE FULLYRESTORED TO PREVIOUS OPERATING AND APPEARANCE CONDITION BYCONTRACTOR.

6. PROVIDE SLEEVES FOR ALL PIPING AND DUCTWORK THAT PENETRATESFULL HEIGHT WALLS, WHETHER SHOWN OR NOT. HOLES THROUGHEXISTING WALLS TO BE CORE DRILLED OR DRILLED WITH HOLE SAW.

7. ADDITIONAL GENERAL NOTES SPECIFIC TO A PARTICULAR DRAWING ARENOTED ON THOSE DRAWINGS.

8. ALL UNDERLINED EQUIPMENT IS SCHEDULED. SEE M400 SERIES DRAWINGSSCHEDULES.

9. SMOKING, ALCOHOL, DRUGS, WEAPONS, AND CONTRABAND ARE STRICTLYFORBIDDEN ON JOB SITE PROPERTY.

10. CONTRACTOR SHALL PROVIDE PLATING AS REQUIRED TO PROTECTSURFACE OF EXISTING ASPHALT PARKING LOT. PROVIDE PLATES UNDERWHEELS OF DUMPSTER, LIFTING DEVICES, AND ANY OTHER EQUIPMENTTHAT COULD SINK INTO THE ASPHALT.

11. FIELD VERIFY EXACT SIZES OF EXISTING PIPING AND DUCT SYSTEMSSHOWN TO BE CONNECTED TO NEW WORK. IN THE EVENT ACTUAL SIZEIS DIFFERENT THAN SHOWN ON DRAWINGS, CONTACT ENGINEER FORDIRECTION PRIOR TO ANY WORK.

12. FOR WALLS THAT GO TO DECK, REFERENCE THE 'A' SERIES DRAWINGS.CONTRACTOR SHALL PROVIDE ACOUSTIC SEALANT AROUND ALL DUCT ANDPIPE PENETRATIONS THROUGH FULL HEIGHT WALLS.

ACID WASTE (SUSPENDED)

ACID WASTE (BURIED)

CONDENSATE DRAINCD

C

FCV

SHUT-OFF VALVE

AREA DRAINAUTOMATIC FLOW CONTROLABOVE FINISHED FLOORAIR HOSE REELAIR HANDLING UNITALTERNATEACCESS PANELAIR SEPARATOR

BLOWDOWNBACKDRAFT/PRESSURE RELIEF DAMPERBRITISH THERMAL UNITBALANCE VALVE

CATCH BASINCAST IRONCENTERLINECLEANOUTCONDENSATEHYDRONIC CONVECTORCABINET UNIT HEATERCOLD WATER

DRY BULBDRINKING FOUNTAINDIAMETERDIFFUSERDOWNSPOUTDIRECT EXPANSION COOLING COIL

EXHAUST AIRENTERING AIR TEMPERATUREELECTRIC BASEBOARD RADIATIONELECTRICAL CONCTRACTOREXHAUST GRILLEELECTRIC CONVECTORELECTRIC CABINET UNIT HEATEREXHAUST FANELECTRICALELEVATIONEND OF MAIN DRIPELECTRIC PROPELLER UNIT HEATEREXHAUST REGISTERELECTRIC RADIANT CEILING PANELEXTERNAL STATIC PRESSUREELECTRIC WATER COOLERELECTRIC WATER HEATEREXPANSION TANKEXISTING

FLOOR DRAIN OR FIRE DAMPERFAN POWERED VAVFLAT ON BOTTOMCOMBINATION FIRE/SMOKE DAMPERHYDRONIC FINNED TUBE RADIATION

GENERAL CONTRACTORGENERAL

HOSE BIBBHEATINGHOT WATERHOT WATER RETURNWALL HYDRANT

INTERNAL DIAMETERINVERTED ELEVATION

LEAVING AIR TEMPERATURELAVATORY

1000 BTU/HOURMECHANICALMANHOLEMECHANICAL CONTRACTORMOP SINKAUTOMATIC MAKE-UP VALVE

NORMALLY CLOSEDNORMALLY OPEN

OUTSIDE AIROUTSIDE AIR DAMPEROPPOSED BLADE DAMPEROUTSIDE DIAMETEROVERFLOW ROOF DRAINOPEN SITE DRAIN

PLATE AND FRAME HEAT EXCHANGERPOST INDICATOR VALVEPLUMBINGPRESSURE REDUCING VALVEPROPELLER UNIT HEATER

RETURN AIRRETURN AIR DAMPERHYDRONIC RADIANT CIELING HEATING PANELREINFORCED CONCRETE PIPEROOF DRAINRECIRCULATINGRETURN GRILLEREDUCED PRESSURE BACKFLOW PREVENTERRETURN REGISTERROOF INTAKE VENTROOF RELIEF VENT

SUPPLY AIRSANITARYSMOKE DAMPERSUPPLY GRILLESHOWER DRAINSINKSUPPLY REGISTERSTAINLESS STEELSHELL AND TUBE HEAT EXCHANGER

TEMPERATURE CONTROL CONTRACTORTEMPERATURE CONTROL PANELTRANSFER GRILLETRANSFER OPENINGTRAP PRIMER LINETYPICAL

URINAL

VARIABLE AIR VOLUMEVETRIFIED CLAY PIPEVARIABLE FREQUENCY DRIVEVENT STACKVARIABLE SPEED DRIVEVENT THROUGH ROOF

WASTEWET BULBWATER CLOSETWASTE STACK

ROOM NUMBERUNITUNDERLINED REPRESENTSSCHEDULED EQUIPMENTFAN COIL CFMFAN COIL SIZE

UNIT/AREA LOCATION IN BUILDINGNUMBER OF AHU IN UNITUNDERLINED REPRESENTSSCHEDULED EQUIPMENT

UNIT/AREA LOCATION IN BUILDINGNUMBER OF FAN IN UNITUNDERLINED REPRESENTSSCHEDULED EQUIPMENTFAN COIL CFM

UNIT/AREA LOCATION IN BUILDING

UNDERLINED REPRESENTSSCHEDULED EQUIPMENTVAV CFMVAV SIZE - SEE SCHEDULE

DRAWN TO SCALE (ACTUAL SIZE)ACTUAL SIZE

SQUARE DIFFUSER DRAWN TOSCALE (ACTUAL SIZE)

CFM

CFM

LINEAR SLOT DIFFUSER DRAWNTO SCALE (ACTUAL SIZE)

CFMER - EXHAUST REGISTERRG - RETURN GRILL

SIZESUPPLY REGISTERCFM

FC - FAN COILBC - BLOWER COIL FC-128G

C-1280

AHU-A4

EF-B6400

VAV-123AA-120

FAN COIL

AIR HANDLING UNIT

FAN

VARIABLE AIRVOLUME BOX

DOUBLE DEFLECTIONSUPPLY REGISTER

EXHAUST/RETURN REGISTER

SUPPLY DIFFUSER

RETURN GRILL FOR RETURNAIR PLENUM CEILING

EF - EXHAUST FANSF - SUPPLY FANRF - RETURN FAN

24/12

400

400

1400 ER

28/12 SR;300

NOMENCLATURE FOR SCHEDULED DEVICES(SEE SCHEUDLES M600 SERIES DRAWINGS FOR ADDITIONAL INFORMATION)

VF - VENTILATION FAN

P:\2

018\

1802

9 - I

SU –

Roo

t Hal

l Low

er L

evel

Cla

ssro

om R

enov

atio

n\D

raw

ings

\MP0

01 -

SYM

BOLS

, ABB

REV

IATI

ON

S, A

ND

GEN

ERAL

NO

TES

- MEC

HAN

ICAL

& P

LUM

BIN

G.d

wg,

5/1/

2018

2:4

5:36

PM

AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
OF SHEETS
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
U
AutoCAD SHX Text
Facilities Management Department
AutoCAD SHX Text
951 Sycamore Street
AutoCAD SHX Text
Terre Haute, Indiana 47809
AutoCAD SHX Text
Phone: (812) 237-8100 Fax: (812) 237-7630
AutoCAD SHX Text
NDIANA
AutoCAD SHX Text
TATE
AutoCAD SHX Text
NIVERSITY
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
PROPERTY NO.:
AutoCAD SHX Text
5/1/2018
AutoCAD SHX Text
CLASSROOM RENOVATION
AutoCAD SHX Text
ROOT HALL
AutoCAD SHX Text
DA# 18029
AutoCAD SHX Text
732 N. CAPITAL AVE. INDIANAPOLIS, IN 46204 PHONE: (317) 634-4672 FAX: (317) 638-8725
AutoCAD SHX Text
PE60910351
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
No.
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
M
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
E.
AutoCAD SHX Text
L
AutoCAD SHX Text
E
AutoCAD SHX Text
I
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
1/8"=1'-0"
AutoCAD SHX Text
NFS
AutoCAD SHX Text
BE
AutoCAD SHX Text
---
AutoCAD SHX Text
MP001
AutoCAD SHX Text
SYMBOLS, ABBREVIATIONS, & GENERAL NOTES MECHANICAL & PLUMBING
Page 5: Evan & Ryan Contractors | Evan & Ryan Contractors

VD

14/1

010

/10

200

200

200

200

50/12

50/12

375

375375

375

175

175

175

175

175

175

175

175

26/10

24/14

18/1

0

10"

10"

10"

10"

8"

8"

8"

8" FLEX TYP. (8)

8"

50/12

8"

8"

8"

8" FLEX TYP. (4)

10" FLEX TYP. (4)

8" FLEX

HS HR

2"

HS HR TWS

TWR

24/12

24/12

TWS

TWR

FPVAV

FPVAV

FPVAV

8"

8"FPVAV

24/24

BY CONTRACTOR OPERATIONS SHALL BE FULLY RESTORED TO PREVIOUS

24/12

CONTRACTORS SHALL PROTECT ALL EXISTING OWNER FACILITIES DURING

24/12

24/12

24/12

24/12

AND FEDERAL REGULATIONS.

TO OWNER.

WITH OWNER'S REPRESENTATIVE.

GENERAL NOTES - DEMOLITION:

OPERATING AND APPEARANCE CONDITION BY THE CONTRACTOR.

MECHANICAL CONTRACTOR SHALL PATCH ALL HOLES LEFT BY REMOVAL OF

CONSTRUCTION. ANY AND ALL OWNER FACILITIES DAMAGED OR DISCONNECTED

COORDINATE ALL SHUT-DOWNS, DELIVERY AND STORAGE OF MATERIALS, ETC.

OR RENOVATION TO MATCH ORIGINAL CONDITION.REPAIR OR REPLACE PIPE AND DUCT INSULATION DAMAGED DURING DEMOLITION

REMOVE ALL HANGERS, STRAPS, BRACKETS, PIPE SUPPORTS, ANCHORS,

OF MATERIAL, ETC. BEFORE BIDDING AND BEFORE BEGINNING ANY DEMOLITION.FIELD VERIFY ALL EXISTING CONDITIONS AS TO EXACT SERVICE, LOCATION, TYPE

DISPOSAL OF DEMOLISHED MATERIALS SHALL COMPLY WITH ALL LOCAL, STATE

LABELED. ALL PIPING, EQUIPMENT, VALVES, ETC., DRAWN LIGHT SHALL REMAIN.REMOVE ALL PIPING, EQUIPMENT, VALVES, ETC., DRAWN DARK DASHED, AND

DEVICES REMOVED ACCIDENTALLY WILL BE REPLACED AT NO ADDITIONAL COSTTHOROUGHLY REVIEW ALL DRAWINGS PRIOR TO ANY DEMOLITION WORK. ANY

CONSTRUCTION SHALL BE REMOVED IN THIS CONTRACT.ALL PIPING DUCTWORK AND EQUIPMENT ABANDONED BY NATURE OF NEW

EXPANSION JOINTS, ETC. ASSOCIATED WITH DUCTWORK AND OR PIPING TO BE

UNLESS SPECIFICALLY NOTED TO BE PERFORMED BY OTHERS. WORK BY OTHERSMECHANICAL OR PLUMBING PIPE, DUCT ETC. IN EXISTING WALLS AND FLOORS.

INDICATED ON 'A' AND 'S' SERIES DRAWINGS. REPAIR SURFACES TO MATCH

11.

10.

REMOVED.

8.

9.

7.

5.

6.

3.

4.

2.

THESE NOTES APPLY TO ALL PLUMBING AND MECHANICAL DEMOLITIONDRAWINGS.

1.

12.

EXISTING SURFACES.

SEE ALSO MP001 FOR GENERAL NOTES.

#

1. REMOVE DIFFUSER/RETURN GRILLE. CLEAN WITH SPRAY CLEANER ANDWIPE CLEAN TO THE SATISFACTION OF THE ENGINEER. SAVE FOR REINSTALLATION. SEE M201

- PLAN NOTES

T

T

T

BULKHEAD7'-8" AFF

1

1 1

1

1 1

1 1

11

1

1

NORTH

LOWER LEVEL PLAN - MECHANICAL DEMOLITIONSCALE: 1/8" = 1'-0"

24/12

24/12

P:\2

018\

1802

9 - I

SU –

Roo

t Hal

l Low

er L

evel

Cla

ssro

om R

enov

atio

n\D

raw

ings

\MD

201

- LO

WER

LEV

EL P

LAN

- M

ECH

ANIC

AL D

EMO

LITI

ON

.dw

g, 5

/1/2

018

2:45

:07

PM

AutoCAD SHX Text
UP
AutoCAD SHX Text
(36.0 36.0 1.5708 "S" 2.0 0.5 7.0 1.0 84.0 "W" "W" "N" 2.5 0.6875 0.25 "casing1" 1 1 1 1 0.5 5.5 4.0 36.0 6.0 4.0 4.0 5.5 30.0 7.25 1.0 "N" "Y" "Y" "N" "N" "Y" "N" "N" 24.0 24.0 12.0 16.0 1.0 "Y" "N" "W" 2.5 "N" 8.0 2 "Y")
AutoCAD SHX Text
1/8"=1'-0"
AutoCAD SHX Text
NFS
AutoCAD SHX Text
BE
AutoCAD SHX Text
---
AutoCAD SHX Text
MD201
AutoCAD SHX Text
LOWER LEVEL PLAN MECHANICAL DEMOLITION
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
OF SHEETS
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
U
AutoCAD SHX Text
Facilities Management Department
AutoCAD SHX Text
951 Sycamore Street
AutoCAD SHX Text
Terre Haute, Indiana 47809
AutoCAD SHX Text
Phone: (812) 237-8100 Fax: (812) 237-7630
AutoCAD SHX Text
NDIANA
AutoCAD SHX Text
TATE
AutoCAD SHX Text
NIVERSITY
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
PROPERTY NO.:
AutoCAD SHX Text
5/1/2018
AutoCAD SHX Text
CLASSROOM RENOVATION
AutoCAD SHX Text
ROOT HALL
AutoCAD SHX Text
DA# 18029
AutoCAD SHX Text
732 N. CAPITAL AVE. INDIANAPOLIS, IN 46204 PHONE: (317) 634-4672 FAX: (317) 638-8725
AutoCAD SHX Text
PE60910351
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
No.
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
M
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
E.
AutoCAD SHX Text
L
AutoCAD SHX Text
E
AutoCAD SHX Text
I
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
A014
AutoCAD SHX Text
A016B
AutoCAD SHX Text
A016
AutoCAD SHX Text
A020
AutoCAD SHX Text
A03
AutoCAD SHX Text
A015B
AutoCAD SHX Text
A015A
AutoCAD SHX Text
A015
AutoCAD SHX Text
A016A
AutoCAD SHX Text
A017
AutoCAD SHX Text
A019
AutoCAD SHX Text
A021
AutoCAD SHX Text
A022
AutoCAD SHX Text
A018
AutoCAD SHX Text
A04
Page 6: Evan & Ryan Contractors | Evan & Ryan Contractors

- PLAN NOTES #

1. REINSTALL EXISTING DIFFUSER/RETURN GRILLE. MODIFY FLEX DUCT ASREQUIRED TO RECONNECT TO SUPPLY DIFFUSERS.

SUPPLY DIFFUSERS TO BE INSTALLED NO CLOSER THAN 4'-0" TO ALL SMOKEDETECTORS. REFER TO T-SERIES AND E-SERIES DRAWINGS FOR ADDITIONALCEILING INSTALLED DEVICES. COORDINATE AND ADJUST DIFFUSER LOCATIONS,

SEE DRAWING M401 FOR CEILING DIFFUSER/EXHAUST AND RETURN REGISTER

FLEX DUCT CONNECTIONS TO DIFFUSERS SHALL BE A MAXIMUM OF 36"

GENERAL NOTES - AIR DISTRIBUTION

2.SCHEDULE.

1.IN LENGTH.

PROVIDE INTERNALLY LINED TRANSFER DUCTS WITH ELBOW IN WALLS OF ALLROOMS ABOVE CEILING WHETHER SHOWN OR NOT.

ALL RETURN GRILLES TO HAVE AN ACOUSTICAL ELBOW. SEEB

M401

3.

4.

7.

THESE ARE NOT FABRICATIONS DRAWINGS. THESE DRAWINGS ARE NOT INTENDEDTO SHOW ALL OFFSETS AS REQUIRED FOR PROPER DUCTWORK INSTALLATION.CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS AND PREPAREFABRICATION DRAWINGS BASED ON EXISTING CONDITIONS. ALL ADDITIONALOFFSETS SHALL BE INCLUDED IN BID PRICE.

5.

AS NEEDED.

6.

REFERENCE M400 SERIES DRAWINGS FOR TYPICAL AND SPECIFIC INSTALLATION REQUIREMENTS FOR EQUIPMENT, ETC.

8. WORKMANSHIP MUST BE IN COMPLIANCE WITH SMACNA STANDARDS.

9. SEE ALSO MP001 FOR ADDITIONAL GENERAL NOTES.

NORTH

LOWER LEVEL PLAN - MECHANICALSCALE: 1/8" = 1'-0"

VD E.

14/1

0 E.

10/1

0 E.

50/12 E.

50/12 E.

375

375375

375

175

175

175

175

175

175

175

175

26/10 E.

24/14 E.

18/1

0 E.

10" E

.

10" E

.10

" E.

10" E

.

8" E.

8" E.

8" E.

8" FLEX TYP. (2) E.8" E.

50/12 E.

8" E.

8" E.

8" E.

8" FLEX E.

10" FLEX TYP. (4) E.

8" FLEX E.

HS HR

2" E.

HS HR TWS

TWR

TWS

TWR

FPVAV E.

FPVAV E.

8" E.

8" E.FPVAV E.

T

T

1 1

1 1

1 1

1 1

11

1

1

FPVAV E.8" FLEX TYP. (6) E.

8" FLEX TYP. (3) E.

8" E.

24/12

24/12

24/12

24/12

24/12

200

200

200

200

24/12

24/12

24/12

P:\2

018\

1802

9 - I

SU –

Roo

t Hal

l Low

er L

evel

Cla

ssro

om R

enov

atio

n\D

raw

ings

\M20

1 - L

OW

ER L

EVEL

PLA

N -

AIR

DIS

TRIB

UTI

ON

.dw

g, 5

/1/2

018

2:44

:01

PM

AutoCAD SHX Text
UP
AutoCAD SHX Text
(36.0 36.0 1.5708 "S" 2.0 0.5 7.0 1.0 84.0 "W" "W" "N" 2.5 0.6875 0.25 "casing1" 1 1 1 1 0.5 5.5 4.0 36.0 6.0 4.0 4.0 5.5 30.0 7.25 1.0 "N" "Y" "Y" "N" "N" "Y" "N" "N" 24.0 24.0 12.0 16.0 1.0 "Y" "N" "W" 2.5 "N" 8.0 2 "Y")
AutoCAD SHX Text
(36.0 36.0 1.5708 "S" 2.0 0.5 7.0 1.0 84.0 "W" "W" "N" 2.5 0.6875 0.25 "casing1" 1 1 1 1 0.5 5.5 4.0 36.0 6.0 4.0 4.0 5.5 30.0 7.25 1.0 "N" "Y" "Y" "N" "N" "Y" "N" "N" 24.0 24.0 12.0 16.0 1.0 "Y" "N" "W" 2.5 "N" 8.0 2 "Y")
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
OF SHEETS
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
U
AutoCAD SHX Text
Facilities Management Department
AutoCAD SHX Text
951 Sycamore Street
AutoCAD SHX Text
Terre Haute, Indiana 47809
AutoCAD SHX Text
Phone: (812) 237-8100 Fax: (812) 237-7630
AutoCAD SHX Text
NDIANA
AutoCAD SHX Text
TATE
AutoCAD SHX Text
NIVERSITY
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
PROPERTY NO.:
AutoCAD SHX Text
5/1/2018
AutoCAD SHX Text
CLASSROOM RENOVATION
AutoCAD SHX Text
ROOT HALL
AutoCAD SHX Text
DA# 18029
AutoCAD SHX Text
732 N. CAPITAL AVE. INDIANAPOLIS, IN 46204 PHONE: (317) 634-4672 FAX: (317) 638-8725
AutoCAD SHX Text
PE60910351
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
No.
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
M
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
E.
AutoCAD SHX Text
L
AutoCAD SHX Text
E
AutoCAD SHX Text
I
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
1/8"=1'-0"
AutoCAD SHX Text
NFS
AutoCAD SHX Text
BE
AutoCAD SHX Text
---
AutoCAD SHX Text
LOWER LEVEL PLAN MECHANICAL
AutoCAD SHX Text
M201
AutoCAD SHX Text
A014
AutoCAD SHX Text
A016B
AutoCAD SHX Text
A016
AutoCAD SHX Text
A020
AutoCAD SHX Text
A003
AutoCAD SHX Text
A015B
AutoCAD SHX Text
A015A
AutoCAD SHX Text
A015
AutoCAD SHX Text
A016A
AutoCAD SHX Text
A017
AutoCAD SHX Text
A019
AutoCAD SHX Text
A021
AutoCAD SHX Text
A022
AutoCAD SHX Text
A018
AutoCAD SHX Text
A04
AutoCAD SHX Text
A023
AutoCAD SHX Text
A025
Page 7: Evan & Ryan Contractors | Evan & Ryan Contractors

STAINLESS STEEL HOSE CLAMPREQUIRED ON INNER FLEX LAYER

INNER FLEX WALL

OUTER FLEX WALL

NYLON TIE STRAP ON OUTER FLEX LAYER

FOR SIZESEE FLOOR PLANLAY-IN DIFFUSER

SUPPORT FROM STRUCTURE

STRUCTURE

INNER FLEX WALL

OUTER FLEX WALL

FOR SIZESEE FLOOR PLANLAY-IN DIFFUSER

NYLON TIE STRAP ON OUTER FLEX LAYER

STAINLESS STEEL HOSECLAMP REQUIRED ONINNER FLEX LAYER

OPTION 1 - PROVIDE 90° METAL ELBOW FOR FINAL CONNECTIONTO DIFFUSER. PROVIDE STAINLESS STEEL HOSE CLAMP FORCONNECTION TO ALL DIFFUSERS.

OPTION 2 - PROVIDE ONE PIECE, FULLY ADJUSTABLE BRACE.LIKE TITUS FLEXRIGHT OR THERMAFLEX FLEX FLOW ELBOW FOR

ADJUSTABLE RADIUS SUPPORT BRACE

CONNECTION TO ALL DIFFUSERS.

STRUCTURE

SUPPORT FROM STRUCTURESUPPORT FROM STRUCTURE

CONNECTION TO DIFFUSERDETAIL 'A'

NO SCALE

EGGCRATE RETURN GRILLE SCHEDULE

ACTUAL SIZE (MARK NO.)

24/6

48/24

24/24

24/12

24/6

24/48 901 - 1500

24/24

12/24

6/24

241 - 500

501 - 900

0 - 240

12/48 48"

12/24

8/24

6/24

24"

18"

12"

NOTES:

2.

1.

1" ACOUSTICAL DUCT LINER

CEILING

EGGCRATE RETURN GRILLE. SEEPLAN OR SCHEDULES FOR SIZES

INSIDE OF DUCT TO BE BLACK.

DUCT SUPPORTED FROM STRUCTURE,NOT CEILING GRID.

X

HANGERS

LISTED DUCT SIZEFROM BELOW FLAT BLACK.PAINT ALL FASTENERS VISIBLE

6"

P:\2

018\

1802

9 - I

SU –

Roo

t Hal

l Low

er L

evel

Cla

ssro

om R

enov

atio

n\D

raw

ings

\M40

1 - D

ETAI

LS A

ND

SC

HED

ULE

S - M

ECH

ANIC

AL.d

wg,

5/1

/201

8 2:

44:3

3 PM

AutoCAD SHX Text
SHEETMETAL DUCT ELBOW TO
AutoCAD SHX Text
BE FULL SIZE OF DIFFUSER NECK.
AutoCAD SHX Text
SUPPORT ELBOW FROM STRUCTURE.
AutoCAD SHX Text
R=1.5 x D
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
OF SHEETS
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
U
AutoCAD SHX Text
Facilities Management Department
AutoCAD SHX Text
951 Sycamore Street
AutoCAD SHX Text
Terre Haute, Indiana 47809
AutoCAD SHX Text
Phone: (812) 237-8100 Fax: (812) 237-7630
AutoCAD SHX Text
NDIANA
AutoCAD SHX Text
TATE
AutoCAD SHX Text
NIVERSITY
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
PROPERTY NO.:
AutoCAD SHX Text
5/1/2018
AutoCAD SHX Text
CLASSROOM RENOVATION
AutoCAD SHX Text
ROOT HALL
AutoCAD SHX Text
DA# 18029
AutoCAD SHX Text
732 N. CAPITAL AVE. INDIANAPOLIS, IN 46204 PHONE: (317) 634-4672 FAX: (317) 638-8725
AutoCAD SHX Text
PE60910351
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
No.
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
M
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
E.
AutoCAD SHX Text
L
AutoCAD SHX Text
E
AutoCAD SHX Text
I
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
1/8"=1'-0"
AutoCAD SHX Text
NFS
AutoCAD SHX Text
BE
AutoCAD SHX Text
---
AutoCAD SHX Text
M401
AutoCAD SHX Text
DETAILS AND SCHEDULES MECHANICAL
AutoCAD SHX Text
NO.
AutoCAD SHX Text
MARK
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
GRILLE
AutoCAD SHX Text
RANGE
AutoCAD SHX Text
CFM
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
DIMEN.
AutoCAD SHX Text
'X'
AutoCAD SHX Text
DUCT
Page 8: Evan & Ryan Contractors | Evan & Ryan Contractors

GENERAL NOTES: # - PLAN NOTES

NORTH

LOWER LEVEL PLAN - FIRE PROTECTION DEMOLITIONSCALE: 1/8" = 1'-0"

FOR FINAL COORDINATION, LAYOUT, CODE COMPLIANCE, AND DESIGN.

ALL NEW WORK IS DRAWN DARK. ALL WORK DRAWN LIGHT AND FOLLOWED

CONTRACTOR SHALL FIELD VERIFY EXISTING PIPE AND EQUIPMENT SIZES,

FIRE PROTECTION SYSTEM WITH THE OWNER, OCCUPANTS OF THE AFFECTED AREA, CONTRACTOR SHALL COORDINATE SHUT DOWN AND DRAIN DOWN OF ANY

CONTRACTORS SHALL PROTECT ALL EXISTING OWNER FACILITIES DURING

BY (E.) IS EXISTING.

AND ANY OTHER AUTHORITY HAVING JURISDICTION.

REMAIN OPERATIONAL.

BEGINNING WORK.

OPERATING AND APPEARANCE CONDITION.

LOCATIONS, ELEVATIONS, MATERIALS, ETC. BEFORE BIDDING OR

CONTRACTOR OPERATIONS SHALL BE FULLY RESTORED TO PREVIOUS

PROVIDE TEMPORARY CAPS AS REQUIRED SO EXISTING SYSTEMS WILL

CONSTRUCTION. ANY FACILITY DAMAGED OR DISCONNECTED BY22.

21.

20.

19.

18.

RESPONSIBILITY OF THIS CONTRACTOR WHETHER SHOWN ON THE DRAWINGS

A SUGGESTED METHOD FOR DESIGN. CONTRACTOR SHALL BE RESPONSIBLE

8. SPRINKLER SYSTEM SHALL BE HYDRAULICALLY CALCULATED, FULLYSUPERVISED, AND INSTALLED ACCORDING TO NFPA 13.

AND SPECIFICATIONS OR NOT.

ALL SPRINKLER SYSTEM ITEMS REQUIRED BY CODE SHALL BE THE

WHERE SPRINKLER HEADS ARE SHOWN ON THE DRAWINGS, LOCATIONS

PIPE ROUTINGS INDICATED ON DRAWINGS ARE DIAGRAMMATIC AND ARE

WITH OTHER DISCIPLINES, AND SHALL BE CONSIDERED FINAL.HAVE BEEN COORDINATED WITH ARCHITECT FOR AESTHETICS AND

11.

12.

10.

THESE NOTES APPLY TO ALL 'FP' SERIES DRAWINGS.1.

CONTRACTOR SHALL COORDINATE WORK WITH ALL OTHER TRADES.7.

UPDATE ALL FIRE PROTECTION SYSTEMS IN CONSTRUCTION AREA THATARE NON-COMPLIANT WITH CURRENT CODES.

13.

CONTRACTOR SHALL OBTAIN FLOW TEST DATA FROM UTILITY PRIORTO DESIGN AND HYDRAULIC CALCULATION OF SPRINKLER SYSTEM.

9.

PROVIDE UPRIGHT SPRINKLER HEADS IN UNFINISHED SPACES (I.E. THOSEWITH EXPOSED STRUCTURE), CONCEALED HEADS IN FINISHED SPACES (I.E.THOSE WITH LAY-IN FOR HARD CEILINGS), SIDEWALL HEADS WHEREIMPRACTICAL TO INSTALL CONCEALED OR UPRIGHT TYPE, OR AS INDICATEDOTHERWISE ON THE DRAWINGS.

REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATIONOF CEILING MOUNTED ITEMS.

ALL UNDERLINED EQUIPMENT IS SCHEDULED. SEE FP600 SERIESDRAWINGS FOR SCHEDULES.

SEE M001 SERIES DRAWINGS FOR SYMBOLS AND ABBREVIATIONS.

PROVIDE SLEEVES FOR ALL PIPING THAT PENETRATES FULL HEIGHTWALLS, WHETHER SHOWN OR NOT.

CONTRACTOR SHALL BE RESPONSIBLE FOR CORE DRILLING ANDCUTTING HOLES THRU WALLS AND FLOORS AS REQUIRED TO INSTALLNEW PIPING, WHETHER SHOWN OR NOT.

ALL FLOOR PENETRATIONS TO BE FIRE STOPPED.

REMOVE ALL PIPING, VALVES, ETC. MADE OBSOLETE AS A RESULT OF NEWCONSTRUCTION.

THOROUGHLY REVIEW ALL DRAWINGS PRIOR TO ANY DEMOLITION WORK.ANY DEVICES REMOVED ACCIDENTALLY WILL BE REPLACED AT NO ADDITIONALCOST TO OWNER.

DISPOSAL OF DEMOLISHED MATERIALS SHALL COMPLY WITH ALL LOCAL,STATE, AND FEDERAL REGULATIONS.

SIZE AND DESIGN SPRINKLER SYSTEMS FOR FUTURE EXPANSION WHEREINDICATED ON DRAWINGS.

FIRE PROTECTION CONTRACTOR IS RESPONSIBLE TO ATTEND ALL BUILDINGWALK-THROUGH'S (AFTER BUILDING IS OCCUPIED AND PRIOR TO THE ENDOF THE 1 YEAR WARRANTY PERIOD) BY THE BUILDING FIRE MARSHAL ANDIS RESPONSIBLE FOR MAKING ANY MODIFICATIONS TO THE SYSTEMREQUIRED AS A RESULT OF THIS BUILDING INSPECTION.

2.

3.

4.

5.

6.

14.

15.

16.

17.

23.

24.

25.

222

2 2 2

222

2 2

2 2

22

2 2

REMOVE SPRINKLER AND RUN-OUT PIPING BACKTO BRANCH PIPING.

SPRINKLER WORK THIS AREA ONLY.

1

P:\2

018\

1802

9 - I

SU –

Roo

t Hal

l Low

er L

evel

Cla

ssro

om R

enov

atio

n\D

raw

ings

\FPD

201

- LO

WER

LEV

EL P

LAN

- FI

RE

PRO

TEC

TIO

N D

EMO

LITI

ON

.dw

g, 5

/1/2

018

2:43

:28

PM

AutoCAD SHX Text
UP
AutoCAD SHX Text
(36.0 36.0 1.5708 "S" 2.0 0.5 7.0 1.0 84.0 "W" "W" "N" 2.5 0.6875 0.25 "casing1" 1 1 1 1 0.5 5.5 4.0 36.0 6.0 4.0 4.0 5.5 30.0 7.25 1.0 "N" "Y" "Y" "N" "N" "Y" "N" "N" 24.0 24.0 12.0 16.0 1.0 "Y" "N" "W" 2.5 "N" 8.0 2 "Y")
AutoCAD SHX Text
1/8"=1'-0"
AutoCAD SHX Text
---
AutoCAD SHX Text
---
AutoCAD SHX Text
---
AutoCAD SHX Text
FPD201
AutoCAD SHX Text
LOWER LEVEL PLAN FIRE PROTECTION DEMOLITION
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
OF SHEETS
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
U
AutoCAD SHX Text
Facilities Management Department
AutoCAD SHX Text
951 Sycamore Street
AutoCAD SHX Text
Terre Haute, Indiana 47809
AutoCAD SHX Text
Phone: (812) 237-8100 Fax: (812) 237-7630
AutoCAD SHX Text
NDIANA
AutoCAD SHX Text
TATE
AutoCAD SHX Text
NIVERSITY
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
PROPERTY NO.:
AutoCAD SHX Text
5/1/2018
AutoCAD SHX Text
CLASSROOM RENOVATION
AutoCAD SHX Text
ROOT HALL
AutoCAD SHX Text
DA# 18029
AutoCAD SHX Text
732 N. CAPITAL AVE. INDIANAPOLIS, IN 46204 PHONE: (317) 634-4672 FAX: (317) 638-8725
AutoCAD SHX Text
PE60910351
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
No.
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
M
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
E.
AutoCAD SHX Text
L
AutoCAD SHX Text
E
AutoCAD SHX Text
I
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
A014
AutoCAD SHX Text
A016B
AutoCAD SHX Text
A016
AutoCAD SHX Text
A020
AutoCAD SHX Text
A03
AutoCAD SHX Text
A015B
AutoCAD SHX Text
A015A
AutoCAD SHX Text
A015
AutoCAD SHX Text
A016A
AutoCAD SHX Text
A017
AutoCAD SHX Text
A019
AutoCAD SHX Text
A022
AutoCAD SHX Text
A018
AutoCAD SHX Text
A04
AutoCAD SHX Text
2
AutoCAD SHX Text
1
Page 9: Evan & Ryan Contractors | Evan & Ryan Contractors

- PLAN NOTES #

NORTH

LOWER LEVEL PLAN - FIRE PROTECTIONSCALE: 1/8" = 1'-0"

GENERAL NOTES:

FOR FINAL COORDINATION, LAYOUT, CODE COMPLIANCE, AND DESIGN.

ALL NEW WORK IS DRAWN DARK. ALL WORK DRAWN LIGHT AND FOLLOWED

CONTRACTOR SHALL FIELD VERIFY EXISTING PIPE AND EQUIPMENT SIZES,

FIRE PROTECTION SYSTEM WITH THE OWNER, OCCUPANTS OF THE AFFECTED AREA, CONTRACTOR SHALL COORDINATE SHUT DOWN AND DRAIN DOWN OF ANY

CONTRACTORS SHALL PROTECT ALL EXISTING OWNER FACILITIES DURING

BY (E.) IS EXISTING.

AND ANY OTHER AUTHORITY HAVING JURISDICTION.

REMAIN OPERATIONAL.

BEGINNING WORK.

OPERATING AND APPEARANCE CONDITION.

LOCATIONS, ELEVATIONS, MATERIALS, ETC. BEFORE BIDDING OR

CONTRACTOR OPERATIONS SHALL BE FULLY RESTORED TO PREVIOUS

PROVIDE TEMPORARY CAPS AS REQUIRED SO EXISTING SYSTEMS WILL

CONSTRUCTION. ANY FACILITY DAMAGED OR DISCONNECTED BY22.

21.

20.

19.

18.

RESPONSIBILITY OF THIS CONTRACTOR WHETHER SHOWN ON THE DRAWINGS

A SUGGESTED METHOD FOR DESIGN. CONTRACTOR SHALL BE RESPONSIBLE

8. SPRINKLER SYSTEM SHALL BE HYDRAULICALLY CALCULATED, FULLYSUPERVISED, AND INSTALLED ACCORDING TO NFPA 13.

AND SPECIFICATIONS OR NOT.

ALL SPRINKLER SYSTEM ITEMS REQUIRED BY CODE SHALL BE THE

WHERE SPRINKLER HEADS ARE SHOWN ON THE DRAWINGS, LOCATIONS

PIPE ROUTINGS INDICATED ON DRAWINGS ARE DIAGRAMMATIC AND ARE

WITH OTHER DISCIPLINES, AND SHALL BE CONSIDERED FINAL.HAVE BEEN COORDINATED WITH ARCHITECT FOR AESTHETICS AND

11.

12.

10.

THESE NOTES APPLY TO ALL 'FP' SERIES DRAWINGS.1.

CONTRACTOR SHALL COORDINATE WORK WITH ALL OTHER TRADES.7.

UPDATE ALL FIRE PROTECTION SYSTEMS IN CONSTRUCTION AREA THATARE NON-COMPLIANT WITH CURRENT CODES.

13.

CONTRACTOR SHALL OBTAIN FLOW TEST DATA FROM UTILITY PRIORTO DESIGN AND HYDRAULIC CALCULATION OF SPRINKLER SYSTEM.

9.

PROVIDE UPRIGHT SPRINKLER HEADS IN UNFINISHED SPACES (I.E. THOSEWITH EXPOSED STRUCTURE), CONCEALED HEADS IN FINISHED SPACES (I.E.THOSE WITH LAY-IN FOR HARD CEILINGS), SIDEWALL HEADS WHEREIMPRACTICAL TO INSTALL CONCEALED OR UPRIGHT TYPE, OR AS INDICATEDOTHERWISE ON THE DRAWINGS.

REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATIONOF CEILING MOUNTED ITEMS.

ALL UNDERLINED EQUIPMENT IS SCHEDULED. SEE FP600 SERIESDRAWINGS FOR SCHEDULES.

SEE M001 SERIES DRAWINGS FOR SYMBOLS AND ABBREVIATIONS.

PROVIDE SLEEVES FOR ALL PIPING THAT PENETRATES FULL HEIGHTWALLS, WHETHER SHOWN OR NOT.

CONTRACTOR SHALL BE RESPONSIBLE FOR CORE DRILLING ANDCUTTING HOLES THRU WALLS AND FLOORS AS REQUIRED TO INSTALLNEW PIPING, WHETHER SHOWN OR NOT.

ALL FLOOR PENETRATIONS TO BE FIRE STOPPED.

REMOVE ALL PIPING, VALVES, ETC. MADE OBSOLETE AS A RESULT OF NEWCONSTRUCTION.

THOROUGHLY REVIEW ALL DRAWINGS PRIOR TO ANY DEMOLITION WORK.ANY DEVICES REMOVED ACCIDENTALLY WILL BE REPLACED AT NO ADDITIONALCOST TO OWNER.

DISPOSAL OF DEMOLISHED MATERIALS SHALL COMPLY WITH ALL LOCAL,STATE, AND FEDERAL REGULATIONS.

SIZE AND DESIGN SPRINKLER SYSTEMS FOR FUTURE EXPANSION WHEREINDICATED ON DRAWINGS.

FIRE PROTECTION CONTRACTOR IS RESPONSIBLE TO ATTEND ALL BUILDINGWALK-THROUGH'S (AFTER BUILDING IS OCCUPIED AND PRIOR TO THE ENDOF THE 1 YEAR WARRANTY PERIOD) BY THE BUILDING FIRE MARSHAL ANDIS RESPONSIBLE FOR MAKING ANY MODIFICATIONS TO THE SYSTEMREQUIRED AS A RESULT OF THIS BUILDING INSPECTION.

2.

3.

4.

5.

6.

14.

15.

16.

17.

23.

24.

25.

CONCEALED STYLE PENDENT SPRINKLER HEAD. CONNECTRUN OUT PIPING TO EXISTING BRANCH PIPING.

SPRINKLER WORK THIS AREA ONLY.

2

1 11

1 11

1 11

1 11

1 11

1 11

1 11

1 11

1 1

P:\2

018\

1802

9 - I

SU –

Roo

t Hal

l Low

er L

evel

Cla

ssro

om R

enov

atio

n\D

raw

ings

\FP2

01 -

LOW

ER L

EVEL

PLA

N -

FIR

E PR

OTE

CTI

ON

.dw

g, 5

/1/2

018

2:42

:58

PM

AutoCAD SHX Text
UP
AutoCAD SHX Text
(36.0 36.0 1.5708 "S" 2.0 0.5 7.0 1.0 84.0 "W" "W" "N" 2.5 0.6875 0.25 "casing1" 1 1 1 1 0.5 5.5 4.0 36.0 6.0 4.0 4.0 5.5 30.0 7.25 1.0 "N" "Y" "Y" "N" "N" "Y" "N" "N" 24.0 24.0 12.0 16.0 1.0 "Y" "N" "W" 2.5 "N" 8.0 2 "Y")
AutoCAD SHX Text
(36.0 36.0 1.5708 "S" 2.0 0.5 7.0 1.0 84.0 "W" "W" "N" 2.5 0.6875 0.25 "casing1" 1 1 1 1 0.5 5.5 4.0 36.0 6.0 4.0 4.0 5.5 30.0 7.25 1.0 "N" "Y" "Y" "N" "N" "Y" "N" "N" 24.0 24.0 12.0 16.0 1.0 "Y" "N" "W" 2.5 "N" 8.0 2 "Y")
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
OF SHEETS
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
U
AutoCAD SHX Text
Facilities Management Department
AutoCAD SHX Text
951 Sycamore Street
AutoCAD SHX Text
Terre Haute, Indiana 47809
AutoCAD SHX Text
Phone: (812) 237-8100 Fax: (812) 237-7630
AutoCAD SHX Text
NDIANA
AutoCAD SHX Text
TATE
AutoCAD SHX Text
NIVERSITY
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
PROPERTY NO.:
AutoCAD SHX Text
5/1/2018
AutoCAD SHX Text
CLASSROOM RENOVATION
AutoCAD SHX Text
ROOT HALL
AutoCAD SHX Text
DA# 18029
AutoCAD SHX Text
732 N. CAPITAL AVE. INDIANAPOLIS, IN 46204 PHONE: (317) 634-4672 FAX: (317) 638-8725
AutoCAD SHX Text
PE60910351
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
No.
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
M
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
E.
AutoCAD SHX Text
L
AutoCAD SHX Text
E
AutoCAD SHX Text
I
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
1/8"=1'-0"
AutoCAD SHX Text
---
AutoCAD SHX Text
---
AutoCAD SHX Text
---
AutoCAD SHX Text
LOWER LEVEL PLAN FIRE PROTECTION
AutoCAD SHX Text
FP201
AutoCAD SHX Text
A014
AutoCAD SHX Text
A016B
AutoCAD SHX Text
A016
AutoCAD SHX Text
A020
AutoCAD SHX Text
A003
AutoCAD SHX Text
A015B
AutoCAD SHX Text
A015A
AutoCAD SHX Text
A015
AutoCAD SHX Text
A016A
AutoCAD SHX Text
A017
AutoCAD SHX Text
A019
AutoCAD SHX Text
A022
AutoCAD SHX Text
A018
AutoCAD SHX Text
A04
AutoCAD SHX Text
A023
AutoCAD SHX Text
A04
AutoCAD SHX Text
1
AutoCAD SHX Text
2
Page 10: Evan & Ryan Contractors | Evan & Ryan Contractors

GENERAL NOTES (RENOVATION):

GENERAL NOTES (DEMOLITION):1. FIELD VERIFY ALL EXTG. CONDITIONS PRIOR TO BEGINNING WORK. THESE

DRAWINGS DO NOT SHOW ALL REQUIRED DEMOLITION WORK. SOME CONDITIONSMAY HAVE BEEN CONCEALED DURING FIELD SURVEYS.

2. ALL DEVICES AND EQUIPMENT SHOWN DASHED OR WITH HEAVY LINE WEIGHT SHALLBE REMOVED IN THEIR ENTIRETY, INCLUDING ALL WIRING TO SOURCE, UNLESSOTHERWISE NOTED.

3. DISPOSAL OF DEMOLISHED MATERIALS SHALL COMPLY WITH ALL LOCAL, STATE &FEDERAL REGULATIONS.

4. CONTRACTORS SHALL PROTECT ALL EXTG. OWNER FACILITIES THAT ARE TO REMAINDURING CONSTRUCTION. ANY FACILITIES DAMAGED OR DISCONNECTED BYCONTRACTOR SHALL BE IMMEDIATELY RESTORED TO PREVIOUS CONDITION.

5. OWNER SHALL HAVE "RIGHT OF FIRST REFUSAL" FOR ALL DEMOLISHED ELECTRICALITEMS. CONTRACTOR SHALL COORDINATE WITH OWNER PRIOR TO BEGINNINGWORK TO DETERMINE WHAT ITEMS THE OWNER MAY BE INTERESTED IN KEEPING.

6. FOR MECH. EQUIPMENT BEING REMOVED, REMOVE ALL ASSOCIATEDDISCONNECTS, CONTROLLERS, WIRING, ETC. COMPLETE. VERIFY W/ M.C.

7. FOR EQUIPMENT OR DEVICES BEING REMOVED FROM WALLS THAT WILL REMAIN,PROVIDE A BLANK COVERPLATE (TO MATCH NEW) ON EXTG. BOX.

8. PROVIDE ADEQUATE SUPPORT FOR EXTG. CABLING/RACEWAYS ABOVE CEILING ASREQ'D. REMOVE ALL OBSOLETE CABLING, WIRING, RACEWAYS, ETC.

9. REMOVE ALL ASSOCIATED ELECTRICAL FOR ANY EXISTING EQUIPMENT BEINGREMOVED BY ANY TRADE. REFER TO ALL DRAWINGS.

10. CONTRACTOR SHALL REMOVE ALL EXTG. DEVICES ON WALLS BEING REMOVED,WHETHER DEVICES ARE SHOWN OR NOT, UNLESS OTHERWISE INSTRUCTED.

11. COORDINATE SCHEDULING OF DEMOLITION WORK WITH OWNER AND ALL TRADES.

12. PATCH ALL EXTG. HOLES THRU WALLS AND FLOORS WHERE EXTG. RACEWAYS ORCABLES ARE REMOVED.

13. IF SERVICE TO AN EXISTING DEVICE TO REMAIN IS INTERRUPTED BY THE REMOVAL OFANOTHER DEVICE, CONTRACTOR SHALL REWIRE THE EXISTING DEVICE THAT IS TOREMAIN AS REQUIRED TO MAINTAIN OPERATION.

VIDEO SURVEILLANCE CAMERA (WALL)

PASSIVE INFRARED DETECTOR

KEYPAD

DOOR CONTACT

SPRINKLER TAMPER SWITCH

SPRINKLER FLOW SWITCH

FIRE ALARM STROBE

HEAT DETECTOR

DUCT TYPE SMOKE DETECTOR

SMOKE DETECTOR

MAGNETIC DOOR HOLDER

FIRE ALARM BELL

FIRE ALARM HORN (SPEAKER)-STROBE

MANUAL PULL STATION

FIRE ALARM ANNUNCIATOR

FIRE ALARM CONTROL PANEL

LABORATORY EQUIPMENT COMPANY (CONTRACTOR)

EXISTING RELOCATED

EXISTING

EXPOSEDEXHAUST

EXISTING

EXISTING

EXTERIOR

EXCAVATIONEXIST

EXP

EXCAV

EXT

EXH

EXR

EXTG

EX

LV LOW VOLTAGE

EQUIPMENT GROUNDING CONDUCTOR

ENERGY MANAGEMENT SYSTEM

EXPLOSIONPROOF; ELECTRIC-PNEUMATIC

EXISTING TO REMAIN

ELECTRICAL METALLIC TUBING

EXTERIOR INSULATION FINISH SYSTEM

ELEVATOR; ELEVATIONELECTRICIAN; ELECTRICAL; ELECTRONIC

ELECTRIC BASEBOARD RADIATION

ELECTRICAL CONTRACTORELECTRONIC BALLAST

ELECTRIC WATER HEATERELECTRIC WATER COOLER

ENGINE; ENGINEERED

EMS

ENGINEER

ESTIMATED

ENCLOSURE

ENERGY SAVER

EQUIPMENTEP

ER

EMT

EQUIP

ENCL

ENGRENG

EWHEWCESTES

EMERGENCYEMERGENCY

EACH

EXHAUST FANEGC

EMERGEM

EBBR

EC

EA

EB

EF

ELEVELECTEIFS

DUSTPROOF; DOUBLE POLE

DUSTTIGHT; DOUBLE THROW

DOMESTIC HOT WATER

DIRECT DIGITAL CONTROL

DECIBEL; DIRECT BURIEDDEEP; DEPTH; DISCHARGE

DOUBLE POLE, SINGLE THROWDOUBLE POLE, DOUBLE THROW

EQUIPMENT ONLY; EAST; ELECTRICAL; EXISTING

DISC DISCONNECT

DOWN

DISHWASHER

DIRECT EXPANSIONDRAWING

DISTRIBUTIONDNDP

DTDW

DX

DPSTDPDT

DWG

DIST

E

DRINKING FOUNTAIN

DIRECT CURRENT

DIFFUSERDIAMETERDIAGONALDIAMETER

D

DFDHW

DDCDCDB

DIAMDIAG

DIFF

DIA

LOCKED ROTOR AMPS

KILOVOLT AMPERE REACTIVE

LABOR; LABORATORY

KILOVOLT AMPERE

LAMP LUMEN DEPRECIATIONLONG; LENGTH; LARGE

LIGHT EMITTING DIODE

POUND; ELL CONDUIT BODY

LIGHT; LIQUID-TIGHT

LOW POWER FACTOR

LED

LRA

LGLF

LM

LPLO

LTR

LLD

LTGLT

LPF

LINEAR FOOT

LUMENLOCKOUT

LETTERLIGHTING

LIGHTING PANEL

KWH

KVAKVKP

KVAR

LABL

KWKW

LECLB

KILOWATT-HOUR

KILOVOLTKEYPAD

LENGTH; LONG

KILOWATT

INCLUDED; INCLUDING

ISOLATED GROUND

THOUSAND CIRCULAR MILS

INVERT ELEVATIONINTERIOR; INTERNAL

JOULE; JUNCTION

INSULATION; INSULATED

KITCHEN EQUIPMENT CONTRACTOR

INTERMEDIATE METAL CONDUIT

INV EL

J-BOXJB

KK

IS

KEC

K

J

KCMIL

KHZ

JUNCTION BOXJUNCTION BOX

KIRK KEY

THOUSAND

INSTANT START

KILOHERTZ

IMP

IFIG

INSTINCL

ININCAND

IMC

INTINSUL

ENGINEERS

IMPEDANCEINCH

INSTALLATION

INCANDESCENT

INSIDE FROSTED

RIGID STEEL CONDUITRTRSCRS

RAINTIGHT

RAPID START

RIGID NON-METALLIC CONDUIT

RUNNING LOAD AMPS

RECIRCULATING

RELAY CONTROL STATION

REFERENCE; REFRIGERATED

REVOLUTIONS PER MINUTE

ROOT MEAN SQUARE

RIGID GALVANIZED STEEL

POLYVINYL CHLORIDE

RESISTANCE; RELOCATED; RECESSED

REMOVE & REPLACE

REQ'D REQUIRED

RNC

RLARMS

RGSRFRET

RPMRRR&R

RP

RETURN FANRETURN

RESTROOM

RAINPROOF

PU

RECEPT

QUAN

PWRPVC

RCS

REFRECIRC

R

PER UNIT

RECEPTACLE

POWER

QUANTITY

PROTECTIVE DEVICE

PUBLIC ADDRESS

POWER FACTOR CORRECTION CAPACITORPOWER FACTOR

PUSHBUTTON; PULL BOX

POST INDICATOR VALVE

POUNDS PER SQUARE INCH GAUGEPOTENTIAL TRANSFORMER

POUNDS PER SQUARE INCHPOUNDS PER SQUARE FOOT

PROFESSIONAL ENGINEER

POWER CONNECTOR; PHOTOCELL

OUTSIDE SCREW AND YOKE

PH PHASE

PL

PNL

PIV

PR

PLBG

PKG

PTPSIGPSIPSFPRI

PILOT LIGHT

PANELBOARDPLUMBING

PACKAGE

PAIRPRIMARY

PD

PA

PFPFCC

P

PCPB

PE

OZOS&Y

POLE; PULL

OUNCE

PHASE; DIAMETER

APPROXIMATELY

POUND; NUMBER

'"

°

O

~@%#

FEETINCHES

DELTADEGREE

ATPERCENT

VAPORTIGHT

VERY HIGH OUTPUTVERY HIGH FREQUENCYVARIABLE FREQUENCY DRIVE

"WIREMOLD" (SURFACE RACEWAY)WIRE GUARD

WELDER OUTLETWEATHERPROOFWEIGHT: WATERTIGHT

TRANSFORMER

WELDED WIRE FABRIC

EXTRA HEAVY DUTY

WIRE; WATT; WIDE; WEST; WASTE

WELL WATER; WARM WHITE

WO

WWF

WPWT

Y

XHD

WW

XFERXFMR

WYE

TRANSFER

VT

VHOVHFVFDVERT

WGW/W

VOL

WM

VERTICAL

VOLUME

WITHFOODSERVICE FACILITIES EQUIPMENT CONTRACTOR

CABINET UNIT HEATER

CONTROL POWER TRANSFORMER

CENTRAL OFFICE GROUND BAR

CONCRETE MASONRY UNITCONSTRUCTION MANAGER

CENTRAL STATION AIR CONDITIONER

COOL WHITE; COLD WATER; CLOTHES WASHER

CURRENT TRANSFORMER

CONDENSATE; CONDUCTORCONTINUOUS; CONTINUED; CONTRACTORCONTCONTROL PANEL

CYLINDER

CUBIC FOOT

CUBIC YARD

COPPER; CUBIC

CUH

CPCPT

CU FT

CSAC

CUCT

CYLCYCW

COLUMNCOMBINATION

CENTRAL OFFICE

COOLING; CEILING

CONCRETECOMPRESSOR

CMCLG

COMB

COGBCO

COL

CMU

COMPR

CONDCONC

BOLTED PRESSURE SWITCH

CONDUIT; CENTIGRADE

BELOW FINISHED GRADE

CLOSED CIRCUIT TELEVISION

CURRENT LIMITING FUSE

CHILLED WATER PUMP

CUBIC FEET; COMPACT FLUORESCENTCANDELA; CLOTHES DRYER

CENTER TO CENTERCABINETCAB

CIRCUIT

CAPACITY

CIRCUIT

CAST IN PLACE

CHILLED WATER

CIRCUIT BREAKER

CIR

CCTVCBCAP

CHWPCHW

CIP

CFCD

CLFCKT

BRANCHBREAKER

BATTERYBOARD

BUILDING

BRBRKR

BPS

BATT

BLDG

C

BFGBD

C/C

INSTITUTE OF ELECTRICAL & ELECTRONICSINTERMEDIATE DISTRIBUTION FRAME

HIGH PRESSURE SODIUM

HOURS PER DAY

HIGH POWER FACTOR

HAND-OFF-AUTOMATIC

HOT WATER; HEAVY WALLHEATING WATER PUMP

HIGH SHORT CIRCUIT

INTERRUPTING CAPACITY

HEATING, VENTILATION & AIR-CONDITIONING

HORSEPOWER; HIGH PRESSURE

HEATERSHTRS

IEEE

HV

IDF

HW

HZHYDHWP

HVAC

IDIC

HIGHT VOLTAGE

HERTZHYDRAULIC

INSIDE DIAMETER

HOHOAHORIZ

HPSHR

HPFHP

HTHTG

HSCHRS/DAY

HORIZONTAL

HIGH OUTPUT

HOUR

HEIGHTHEATING

GROUND FAULT PROTECTOR

GROUND FAULT CIRCUIT INTERRUPTER

GENERAL PURPOSE

GALVANIZED RIGID CONDUIT

HEATING, AIR CONDITIONING & REFRIGERATION

GENERAL CONTRACTOR

GROUND; GROUNDEDGALVANIZED RIGID STEEL

GALLONS PER MINUTE

GENERAL; GENERATOR

GROUND FAULT INTERRUPTER

HIGH INTERRUPTING CAPACITY

GP

GRC

HACR

HH

GRD

GPM

H

HD

GRS

HIC

HGHAND HOLE

HIGH

HEAVY DUTYMERCURY

GFP

GFCI

GCGALV

GFI

GND

GEN

GALGAG

GALVANIZED

GROUND

GALLON

GROUNDGAUGE

AMPEREA

AMERICAN NATIONAL STANDARDS INSTITUTE

AMPERE FUSE; AMPERE FRAME

AUTOMATIC TRANSFER SWITCH

ABOVE FINISHED FLOOR

ALTERNATING CURRENT; ARMORED CABLE

AMPERE INTERRUPTING CAPACITY

AMERICAN WIRE GAUGE

ABOVE FINISHED GRADE

AMPERE TRIPASYMMETRICAL

AUXILIARY

AMPERE

ARCHITECT

AVERAGE

APPROXIMATEACCESS PANEL

ANSI

ASYMATATSAUX

APPROXAP

AMP

ARCH

AWGAVG

ADJUSTABLE

AIR-CONDITIONING

ALUMINUM

ALUMINUMALTERNATE

AIR HANDLING UNIT

AF

A/C

AFF

ADJAC

ALTALAICAHUAFG

ALUM

F FUSED; FAHRENHEIT

FIRE ALARM CONTROL PANELFIRE ALARM ANNUNCIATOR PANEL

FITTING; FOOTING

FULL LOAD AMPS

FULL VOLTAGE NON-REVERSING

FLUORINATED ETHYLENE PROPYLENE

FEET PER MINUTE

FUSED DISCONNECT

FREQUENCY MODULATION; FACTORY MUTUAL

FTG

FLAFIXT

FPMFM

FLRFLUOR

FVNRFURN

FTFR

FIXTURE

FLOOR

FURNISHED

FOOT; FEETFIRE RATING

FLUORESCENT

FACPFAAP

FCU

FDR

FFEC

FC

FA

FIGFIN

FEP

FDFAN COIL UNIT

FEEDER

FOOT-CANDLE

FIRE ALARM

FIGUREFINISHED

MANUFACTURINGMFG

NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

MERCURY VAPOR, MEGAVOLT; MEDIUM VOLTAGE

NON-AUTOMATIC

NATIONAL ELECTRICAL CODE

NOT TO SCALE

NORMALLY CLOSED

ON CENTER; OVERCURRENTOVERHEAD AND PROFIT

NUMBER; NORMALLY OPENNON-METALLIC SHEATHED CABLE

NON-FUSED DISCONNECTNOT IN CONTRACT

OUTSIDE DIAMETER

OVERHEAD DOOR

OFFICE PRINCIPAL GROUND POINT

OVERHEAD DISTRIBUTION SYSTEM

NOT AVAILABLE; NOT APPLICABLE

NM

NTS

OC

OL

O&P

NO

OHODSOD

OHD

OPGPOVERLOAD

OVERHEAD

NA

NECNEMA

ND

NL

NC

N/A

NAT

NFDNIC

NF

NORMAL DUTY

NIGHT LIGHT

NATURAL

NON-FUSED

MAIN LUG ONLY

MANUAL TRANSFER SWITCH

MAXIMUM OVERCURRENT PROTECTION

MANUFACTURER

MISCELLANEOUSMINIMUM; MINUTE

NORTH; NEW; NEUTRAL

MEGAVOLT AMPERES

MULTI; MULTIPLY

MANHOLE; METAL HALIDE; MAN-HOUR

MEGAVOLT AMPERES REACTIVE

MALLEABLE IRON; MINERAL INSULATED

MOCP

MTGMTS

MTDMOG

MW

MVAMV

MVAR

N

MULT

MOUNTING

MOGULMOUNTED

MEGAWATT

MIC

MLO

MHMFR

MISCMIN

MIMHZ

MOBILMO

MICROPHONE

MEGAHERTZ

MOBILIZATIONMONTH

TELEPHONE TERMINAL BOARD

TRANSIENT VOLTAGE SURGE SUPPRESSOR

UNDER (CABINET OR COUNTER)

UNDERGROUND

UNLESS OTHERWISE INDICATED

UNDERVOLTAGE RELAY (RELEASE)

TRIGGER START

UNIT HEATER

VOLT AMPERES

VIDEO DISPLAY TERMINALVARIABLE AIR VOLUME

VOLT; VENTILATION

UNSHIELDED TWISTED PAIR

UNDERWRITERS LABORATORYULTRA HIGH FREQUENCY

UNDERGROUND FEEDER

VOLT-AMPERES REACTIVE

UL

UOIUTIL

UVR

UNFIN

V

UTP

VDTVAVVARVA

UTILITY

UNFINISHED

TTB

TVSS

UC

UGUF

TYP

TV

TS

UHFUH

TYPICAL

TELEVISION

SOLENOID VALVE

SWITCHING DUTY

SYMMETRICAL

TIME CLOCKTERMINAL BLOCK

TIME DELAY

TOTAL HARMONIC DISTORTION: THREAD

TOP OF FINISHED FLOOR

TAMPER RESISTANT

SQUARE YARDSWITCHBOARD

TRANSFORMER

TEMPERATURE CONTROL CONTRACTOR

TETRAFLUOROETHYLENE

TEMPERATURE; TRANSFORMER

SUBCONTRACTORS

TTBTC

TD

THD

TELE

TFF

TR

TFMR

TFE

TH

TCC

TELEPHONE

THICK

SV

SWD

SYM

SWBRD

SW

SURFSUBS

SYSSYN

SY

SYNTHETICSYSTEM

SWITCH

SURFACE

METAL CLAD CABLE; MECHANICAL CONTRACTOR;

M THOUSAND; MATERIAL; MECHANICAL; METER

MOTOR CONTROLLER

MASTER ANTENNA TELEVISION

MOLDED CASE CIRCUIT BREAKERMOTOR CONTROL CENTERMAIN CIRCUIT BREAKER

MOTOR CIRCUIT SWITCHMAIN DISTRIBUTION FRAMEMAIN DISTRIBUTION PANELBOARD

MINIMUM CIRCUIT AMPS

MAGNETIC STARTER

MOTOR CIRCUIT PROTECTORTHOUSAND CIRCULAR MILS

MCAMCB

MCCBMCC

MDPMDFMCSMCPMCM

MEDMECH MECHANICAL

MEDIUM

MAN

MATV

MA

MAG STRMAINT

MACH

MCMAX

MATMANUALMAINTENANCE

MACHINEMILLIAMPERE

MAXIMUM

MATERIAL

S SOUTH

SERVICE RACEWAY; SURFACE RACEWAY

SLIM LINE; SERVICE LATERALSOLID NEUTRAL

SECONDARYSUPPLY FAN; SQUARE FOOT

SERVICE DROPSHORT CIRCUIT RATING

SQUARE INCHSQUARE FOOT

START/STOPSTEEL: SHUNT TRIP; SINGLE THROW

SINGLE POLE

STAINLESS STEEL; SAFETY SWITCH

SINGLE POLE, SINGLE THROW

SINGLE POLE, DOUBLE THROW

SERVICE ENTRANCE; SERVICE EQUIPMENT

STRUCTURAL

SPKR SPEAKER

STRUCT

SQ

SR

SPST

SQ INSQ FT

STRSTD

SSS/SST

SQUARE

STARTERSTANDARD

SDSCRSCHED

SLSN

SFSECSE

SPDT

SP

SCHEDULE

SWITCH, THREE WAY

SWITCH LEG

SWITCH, DIMMER

SWITCH, WEATHERPROOF

SWITCH, WITH PILOT LIGHT

SWITCH, KEY OPERATED

SWITCH, FOUR WAY

3-WAY

SWITCH LEG

1

a 1

'F1'

SURFACE RACEWAY ("WIREMOLD")

UNDERFLOOR DUCT & JUNCTION BOX, DUAL SYSTEM

UNDERFLOOR DUCT & JUNCTION BOX, TRIPLE SYSTEM

UNDERFLOOR DUCT & JUNCTION BOX, SINGLE SYSTEM

CONDUIT, CAPPED

CONDUIT, TURNING DOWN

CONDUIT, TURNING UP

CONDUIT, EXPOSED

CONDUIT, BELOW FLOOR

CONDUIT, IN WALL OR CEILING

PANEL, FLUSH

DUPLEX RECEPTACLEGROUND FAULT CIRCUIT INTERRUPTER/WEATHERPROOF ROOF

GROUND FAULT CIRCUIT INTERRUPTER DUPLEX RECEPTACLE

ISOLATED GROUND DUPLEX RECEPTACLE

DOUBLE DUPLEX (QUAD) RECEPTACLE

SINGLE RECEPTACLE

SWITCH, DOUBLE POLE

SWITCH, SINGLE POLE

SPECIAL OUTLET OR EQUIPMENT CONNECTION (AS NOTED)

FLOOR OUTLET

DUPLEX RECEPTACLE

PULL BOX

JUNCTION BOX

LIGHT FIXTURE TYPE

DOUBLE DUPLEX (QUAD) GROUND FAULT CIRCUITINTERRUPTER RECEPTACLE

CIRCUIT NUMBER

CIRCUIT NUMBER

MULTI-TECHNOLOGY CEILING OCCUPANCY SENSING

LIGHT, CEILING

LIGHT, CEILING

LIGHT, WALL

EXIT LIGHT, CEILING

EXIT LIGHT, WALL

EXIT LIGHT WITH DIRECTIONAL ARROW, CEILING

EXIT LIGHT WITH DIRECTIONAL ARROW, WALL

EMERGENCY LIGHTING UNIT

TRACK LIGHT FIXTURE

NIGHT LIGHT WITH 'NL' SUBSCRIPT

EMERGENCY LIGHT

ULTRASONIC CEILING OCCUPANCY SENSING

PASSIVE INFRARED CEILING OCCUPANCY SENSING

SINGLE POLE WALL OCCUPANCY SENSOR

TWO POLE WALL OCCUPANCY SENSOR

PANEL, SURFACE

CONTROL PANEL (AS NOTED), FLUSH

CONTROL PANEL (AS NOTED), SURFACE

SURGE PROTECTIVE DEVICESPD

SCCR SHORT-CIRCUIT CURRENT-RATING

A1 A1-1

CIRCUIT NUMBER

PANEL NAME

PANEL NAME

* INDIVIDUAL CIRCUITS NUMBERSARE LOCATED AT EACHDEVICE

NEUTRAL CONDUCTOR

PHASE (OR CONTROL) CONDUCTOR

GROUND CONDUCTOR

ISOLATED GROUND CONDUCTOR

INDICATES MINIMUM WIRE SIZE PER SPECIFICATIONS

S1

S2

OS

PI

US

ISOLATED GROUND DOUBLE DUPLEX (QUAD) RECEPTACLE

WP

J

P

FACP

FAA

F

F

F

F

DH

F

D

H

FS

TS

VCC VOICE COMMAND CENTER

DC

KP

PIR

C

VIDEO SURVEILLANCE CAMERA (CEILING)C

INTERCOM CALL SWITCH

WALL MOUNTED SPEAKER (ROUND)

BUZZER

WALL MOUNTED SPEAKER (SQUARE)

CEILING MOUNTED SPEAKER (ROUND)

MICROPHONE OUTLET

SPEAKER VOLUME CONTROL

BELL

CEILING MOUNTED SPEAKER (SQUARE)

HORN-PAGING

S

S

V

M

P

S

S

CLOCK (WALL)

CLOCK (CEILING)

PUSHBUTTON

UP/DOWN PUSHBUTTON

UP/DOWN/STOP PUSHBUTTON

1-PHASE MOTOR

3-PHASE MOTOR

DISCONNECT

MANUAL MOTOR STARTER

MANUAL MOTOR STARTER WITH PILOT SWITCH

MAGNETIC MOTOR STARTER

COMBINATION DISCONNECT & MAGNETIC MOTOR STARTER

P

SMALL TRANSFORMER

TIMECLOCK

PHOTOCELL

TC

PC

R

LC

RELAY PANEL

LIGHTING CONTACTOR

HORN

ELECTRICAL GROUND

DROP CORD (AS NOTED)

POWER POLE

F FIRE ALARM STROBE (CEILING MOUNTED)

EMERGENCY VOICE-ALARM LOUDSPEAKERA

CARD READERCR

ELECTRIC LATCHEL

POWER SUPPLYPS

CONTROL PANELCP

SWITCH, SPRING WOUND, INTERVAL TIME SWITCH

1. COORDINATE LOCATIONS OF ALL DEVICES TO BE INSTALLED IN CEILINGS (LIGHTS,SPEAKERS, DETECTORS, ETC.) WITH THE ARCHITECTURALREFLECTED CEILING PLANS.

2. NOTIFY ENGINEER OF ANY CONFLICTS PRIOR TO INSTALLATION.

3. ALL 120 VOLT CIRCUITS SHALL UTILIZE SEPARATE INDEPENDENT NEUTRAL CONDUCTORS.DO NOT SHARE NEUTRALS.

4. CONTRACTOR SHALL COORDINATE WITH ALL TRADES. NO ADDITIONALCOMPENSATION WILL BE ALLOWED FOR INCORRECT WORK, OR FOR INFRINGEMENTUPON OTHERS WORK, DUE TO A LACK OF COORDINATION.

5. DEVICES IN GENERAL SHALL BE CENTERED IN WALL SPACE IN WHICH THEY AREINSTALLED OR THEY SHALL BE SPACED SYMMETRICALLY (FOR EXAMPLE, CENTERDEVICES WHEN MOUNTED ON FACE OF COLUMNS).

6. COORDINATE & VERIFY LOCATIONS OF DEVICES W/ BLOCK COURSING, FINISHMATERIALS, CASEWORK, ETC. PRIOR TO ROUGH-IN.

7. WIRING TO ALL RECEPTACLES ON DEDICATED CIRCUITS SHALL BE #10 MINIMUMUNLESS OTHERWISE NOTED.

8. ALL WIRING SHALL BE MINIMUM #12 AWG. IN 3/4" CONDUIT UNLESS OTHERWISE NOTEDOR REQUIRED.

9. COORDINATE LOCATION OF RECEPTACLES AT ELECTRIC WATER COOLERS (EWC) W/EWC MANUFACTURER. PROVIDE DUPLEX GFCI RECEPTACLE SO THAT IT IS CONCEALEDBY EWC HOUSING.

10. COORDINATE EXACT LOCATION OF ALL DEVICES, AND DEVICE/COVER COLORS, WITHARCHITECT PRIOR TO ROUGH-IN.

11. PROVIDE ACCESS PANELS AS REQUIRED TO SERVICE PULL/JUNCTION BOXESCONCEALED IN WALLS OR CEILINGS. COORDINATE LOCATIONS WITHARCHITECT/ENGINEER.

12. PROVIDE EXTENSION RING ON EXISTING DEVICE BOXES TO ACCOMODATE NEW WALLFINISHES AS REQUIRED.

VOICE/DATA/COAX (RF) OUTLET (ONE CAT. 6A VOICE/ONE CAT. 6A DATA/ONE RG-6 COAX - JACKS AND CABLES)

VOICE/DATA OUTLET (ONE CAT. 6A VOICE/ONE CAT. 6A DATA - JACKS AND CABLES)

SINGLE OR SPECIAL OUTLET AS INDICATED (V=CAT. 6A VOICE; D=CAT. 6A DATA; C=RG-6 COAX), EXAMPLE:

WALL PHONE OUTLET (ONE CAT. 6A VOICE - JACK AND CABLE)W

D =ONE CAT. 6A DATA - JACK AND CABLE

VOICE/DATA/DATA/COAX (RF) OUTLET (ONE CAT. 6A VOICE/TWO CAT. 6A DATA/ONE RG-6 COAX - JACKS AND CABLES)2D

WIRELESS ACCESS CONNECTION POINT (TWO CAT. 6A DATA - JACKS AND CABLES) - PROVIDE 10'-0" SERVICE LOOP AND RED RJ45 JACKS ABOVE CEILING. AP

NOTE: COLOR OF DATA JACKS SHALL MATCH WIRING DEVICES, AP JACKS SHALL BE RED AND PHONE JACKS SHALL BE BLUE, UNLESS OTHERWISE DIRECTED.

EMERGENCY WALL PHONE OUTLET (ONE CAT. 6A VOICE - JACK AND CABLE)911

DATA/DATA/COAX (RF) OUTLET (TWO CAT. 6A DATA/ONE RG-6 COAX - JACKS AND CABLES)D

TELEVISION OUTLET (ONE CAT. 6A DATA/ONE RG-6 COAX - JACK AND CABLE) - VERIFY EXACT OUTLET (& DUPLEX RECEPT.) LOCATION WITH OWNER.TV

EMERGENCY NOTIFICATION SYSTEM WALL OUTLET (ONE CAT. 6A DATA - JACK AND CABLE)ENS

CIRCUIT NUMBER:

PANEL - CIRCUIT NUMBER(I.E. A1-1)

MULTIPLE INDIVIDUAL CIRCUIT NUMBERS:

PANEL - CIRCUIT NUMBER, CIRCUIT NUMBER, CIRCUIT NUMBER(I.E. A1-1,3,5)

2-POLE CIRCUIT NUMBER

PANEL - CIRCUIT NUMBER/CIRCUIT NUMBER(I.E. A1-1/3)

3-POLE CIRCUIT NUMBER

PANEL - CIRCUIT NUMBER/CIRCUIT NUMBER/CIRCUIT NUMBER(I.E. A1-1/3/5)

PROJECTOR (SEE A/V SPECS)PR

P:\2

018\

1802

9 - I

SU –

Roo

t Hal

l Low

er L

evel

Cla

ssro

om R

enov

atio

n\D

raw

ings

\E00

1 - S

YMBO

LS, A

BBR

EVIA

TIO

NS,

AN

D G

ENER

AL N

OTE

S - E

LEC

TRIC

AL.d

wg,

5/1/

2018

2:4

0:26

PM

AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
OF SHEETS
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
U
AutoCAD SHX Text
Facilities Management Department
AutoCAD SHX Text
951 Sycamore Street
AutoCAD SHX Text
Terre Haute, Indiana 47809
AutoCAD SHX Text
Phone: (812) 237-8100 Fax: (812) 237-7630
AutoCAD SHX Text
NDIANA
AutoCAD SHX Text
TATE
AutoCAD SHX Text
NIVERSITY
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
PROPERTY NO.:
AutoCAD SHX Text
5/1/2018
AutoCAD SHX Text
CLASSROOM RENOVATION
AutoCAD SHX Text
ROOT HALL
AutoCAD SHX Text
DA# 18029
AutoCAD SHX Text
732 N. CAPITAL AVE. INDIANAPOLIS, IN 46204 PHONE: (317) 634-4672 FAX: (317) 638-8725
AutoCAD SHX Text
PE60910351
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
No.
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
M
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
E.
AutoCAD SHX Text
L
AutoCAD SHX Text
E
AutoCAD SHX Text
I
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
ABBREVIATIONS, SYMBOLS AND NOTES - ELECTRICAL
AutoCAD SHX Text
E001
AutoCAD SHX Text
%%UELECTRICAL ABBREVIATIONS
AutoCAD SHX Text
s
AutoCAD SHX Text
a
AutoCAD SHX Text
3
AutoCAD SHX Text
s
AutoCAD SHX Text
D
AutoCAD SHX Text
WP
AutoCAD SHX Text
P
AutoCAD SHX Text
K
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
s
AutoCAD SHX Text
s
AutoCAD SHX Text
s
AutoCAD SHX Text
s
AutoCAD SHX Text
s
AutoCAD SHX Text
2
AutoCAD SHX Text
s
AutoCAD SHX Text
s
AutoCAD SHX Text
W
AutoCAD SHX Text
%%ULIGHT FIXTURES
AutoCAD SHX Text
%%USWITCHES
AutoCAD SHX Text
%%UPANELS
AutoCAD SHX Text
%%URECEPTACLES AND OUTLETS
AutoCAD SHX Text
%%URACEWAYS
AutoCAD SHX Text
%%UTYPICAL WIRING DESIGNATIONS
AutoCAD SHX Text
%%UTYPICAL DEVICE DESIGNATIONS
AutoCAD SHX Text
%%UROOM CIRCUIT DESIGNATIONS
AutoCAD SHX Text
%%UFIRE ALARM SYSTEMS
AutoCAD SHX Text
%%UELECTRONIC SECURITY
AutoCAD SHX Text
%%UTECHNOLOGY
AutoCAD SHX Text
%%UPUBLIC ADDRESS
AutoCAD SHX Text
%%UMISCELLANEOUS
AutoCAD SHX Text
%%UPOWER EQUIPMENT
AutoCAD SHX Text
T
AutoCAD SHX Text
%%UCIRCUIT DESCRIPTIONS
AutoCAD SHX Text
TS
AutoCAD SHX Text
s
AutoCAD SHX Text
NL
AutoCAD SHX Text
1/8"=1'-0"
AutoCAD SHX Text
DEW
AutoCAD SHX Text
DEW
AutoCAD SHX Text
DED
Page 11: Evan & Ryan Contractors | Evan & Ryan Contractors

NORTH

LOWER LEVEL PLAN - ELECTRICAL DEMOLITIONSCALE: 1/8" = 1'-0"

F

AP

8. REMOVE POWER POLE AND ALL ASSOCIATED WIRING.

9. FIRE ALARM STROBE SHALL REMAIN.

10. CLOCK TO REMAIN.

11. ABANDONED DEVICE BOX. REMOVE WIRING TO SOURCE.

12. REMOVE RECEPTACLE AND WIRING ABOVE CEILING TO PROJECTOR.REMOVE PROJECTOR AND ALL ASSOCIATED WIRING. TURN PROJECTOROVER TO OWNER.

13. REMOVE EMERGENCY LIGHT AND WIRING.

14. REMOVE FIRE ALARM SMOKE DETECTOR AND MODIFY WIRING ASREQUIRED TO MAINTAIN SERVICE TO OTHER DEVICES THAT ARE TOREMAIN. SEE T201 FOR NEW DEVICES.

15. WIRELESS ACCESS POINT TO BE REMOVED. REMOVE ALL ASSOCIATEDCABLING BACK TO SOURCE. TURN ACCESS POINT OVER TO OWNER.

16. EXISTING EMERGENCY NOTIFICATION PHONE TO REMAIN.

GENERAL NOTES1. SEE DRAWING E001.

S

F

SS S

F

AP

PR

PR

F

F

8

8

8

8

8

2

3

221

8

8

8

8

8

32

ENS

2

2

F

2

3

22

3

2

2

2

J

6

PLAN NOTES#

1. REMOVE LIGHTING AND MAKE 277V CIRCUIT SAFE FOR REUSE. SEEDRAWING E201. 277V CIRCUIT FROM PANEL 'HBB' SERVES 2X4 LIGHTS.REMOVE 120V CIRCUIT FROM PANEL 'LBB-2' THAT SERVES DOWNLIGHTS.

2. RECEPTACLES AND TECHNOLOGY DEVICES SHALL REMAIN UNLESSOTHERWISE NOTED.

3. REMOVE LIGHT SWITCHES AND DIMMER.

4. MAKE SAFE EMERGENCY LIGHTING CIRCUIT FOR RE-USE. SEE DRAWINGE201.

5. EXISTING PANEL TO REMAIN.

6. REMOVE ALL LIGHTS, RECEPTACLES, TECHNOLOGY OUTLETS, WIRING, ETCIN THEIR ENTIRETY, UNLESS OTHERWISE NOTED.

7. REMOVE TWO-COMPARTMENT SURFACE RACEWAY AND ALLASSOCIATED WIRING.

(277/480V) 'HBA'

(120/208V) 'LBA-1'

(120/208V) 'LBA-2'

5

5

5

5

14

10

10

9

11

9

COMPUTER ROOMPANEL (120/208V)

14

8

6

6

13 14

14

(TYP.)

5UNNAMED PANEL(120/208V)

12

13

7 (TYP.)

1313 12

15

15

DEMOLITION LEGENDWORK TO BE REMOVED.

WORK TO REMAIN.

P:\2

018\

1802

9 - I

SU –

Roo

t Hal

l Low

er L

evel

Cla

ssro

om R

enov

atio

n\D

raw

ings

\ED

201

- LO

WER

LEV

EL P

LAN

- EL

ECTR

ICAL

DEM

OLI

TIO

N.d

wg,

5/1

/201

8 2:

42:3

2 PM

AutoCAD SHX Text
UP
AutoCAD SHX Text
(36.0 36.0 1.5708 "S" 2.0 0.5 7.0 1.0 84.0 "W" "W" "N" 2.5 0.6875 0.25 "casing1" 1 1 1 1 0.5 5.5 4.0 36.0 6.0 4.0 4.0 5.5 30.0 7.25 1.0 "N" "Y" "Y" "N" "N" "Y" "N" "N" 24.0 24.0 12.0 16.0 1.0 "Y" "N" "W" 2.5 "N" 8.0 2 "Y")
AutoCAD SHX Text
ED201
AutoCAD SHX Text
LOWER LEVEL PLAN ELECTRICAL DEMOLITION
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
OF SHEETS
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
U
AutoCAD SHX Text
Facilities Management Department
AutoCAD SHX Text
951 Sycamore Street
AutoCAD SHX Text
Terre Haute, Indiana 47809
AutoCAD SHX Text
Phone: (812) 237-8100 Fax: (812) 237-7630
AutoCAD SHX Text
NDIANA
AutoCAD SHX Text
TATE
AutoCAD SHX Text
NIVERSITY
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
PROPERTY NO.:
AutoCAD SHX Text
5/1/2018
AutoCAD SHX Text
CLASSROOM RENOVATION
AutoCAD SHX Text
ROOT HALL
AutoCAD SHX Text
DA# 18029
AutoCAD SHX Text
732 N. CAPITAL AVE. INDIANAPOLIS, IN 46204 PHONE: (317) 634-4672 FAX: (317) 638-8725
AutoCAD SHX Text
PE60910351
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
No.
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
M
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
E.
AutoCAD SHX Text
L
AutoCAD SHX Text
E
AutoCAD SHX Text
I
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
1/8"=1'-0"
AutoCAD SHX Text
DEW
AutoCAD SHX Text
DEW
AutoCAD SHX Text
DED
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
A014
AutoCAD SHX Text
A016B
AutoCAD SHX Text
A016
AutoCAD SHX Text
A020
AutoCAD SHX Text
A03
AutoCAD SHX Text
A015B
AutoCAD SHX Text
A015A
AutoCAD SHX Text
A015
AutoCAD SHX Text
A016A
AutoCAD SHX Text
A017
AutoCAD SHX Text
A019
AutoCAD SHX Text
A022
AutoCAD SHX Text
A018
AutoCAD SHX Text
A04
Page 12: Evan & Ryan Contractors | Evan & Ryan Contractors

PLAN NOTES#

1. PROVIDE 0-10V WALL BOX DIMMERS, LIKE LEVITON RENOIR II SERIES.VERIFY COMPATIBILITY WITH LIGHT FIXTURES. MULTI-LOCATION ASNECESSARY.

2. INSTALL LIGHTS IN EXISTING CEILING. CONNECT LIGHTS TO EXISTING 277VOLT CIRCUIT FROM EXISTING PANEL 'HBB'.

3. INSTALL LIGHTS IN EXISTING CEILING. CONNECT LIGHTS TO EXISTING 277VOLT CIRCUIT FROM EXISTING PANEL 'HBB' AND EXISTING EMERGENCYLIGHTING CIRCUIT. FIXTURE TO CONTAIN (2) GENERATOR TRANSFERDEVICES.

4. CONNECT LIGHTS TO EXISTING LIGHTING CIRCUIT. VERIFY SOURCE ANDVOLTAGE IN FIELD.

5. EXISTING PANEL

GENERAL NOTES

NORTH

LOWER LEVEL PLAN - LIGHTINGSCALE: 1/8" = 1'-0"

1. SEE DRAWING E001.

D cD b

D aD c

D bD a

F1 b F1 a F1 a

F1 b F1 a F1 a

F1 b F1 a

F1 b F1 a F1 a

F1 b F1 a F1 a

F1 b F1 a

F1 b F1 a F1 a

F1 b F1 a F1 a

F1 a F1 a F1 a

F1 b F1 b F1 b

D bD a

F2

c

F2

c

F2

c

F2

c

F2

c

F2

c

1

1

1

(277/480V) 'HBA'

(120/208V) 'LBA-1'

(120/208V) 'LBA-2'COMPUTER ROOMPANEL (120/208V)

UNNAMED PANEL(120/208V)

4

F1E

a

4

4

F1E a

3

3

D b

1

D cD b1

D c

MARK FIXTUREMOUNTING VOLTAGE MANUFACTURER(S)

'F1' IN GRID

DESCRIPTION

LED UNIVERSAL FINELITE HPR-LED-A-2X4-DCO-H-835 SERIES2-FOOT BY 4-FOOT ARCHITECTURAL TROFFER, ANGLED DOOR,DIFFUSE CENTER OPTIC, 0-10V DIMMING, HIGH OUTPUT, NOMINAL 41WATTS, MINIMUM 5416 LUMENS, UNIVERSAL VOLTAGE.

RECESSED

LAMP

41

LOAD (VA) TEMP.TYPE LUMENS

3500K 5416

'F1E' SAME AS F1, PLUS (2) GENERATOR TRANSFER DEVICES.

'F2' IN GRID LED UNIVERSAL FINELITE HPW-LED-4'-FR-H-835 SERIES4' LINEAR ASYMMETRIC LED WALL WASH, FROSTED LENS, HIGHOUTPUT, NOMINAL 28 WATTS, MINIMUM 3038 LUMENS, UNIVERSALVOLTAGE.

RECESSED 28 3500K

(MIN.)

3038(MIN.)

RENOVATION LEGENDWORK TO BE INSTALLED

EXISTING WORK TO REMAIN.

5

5

5

5

5

OS

OS

OS

OS

OS

P:\2

018\

1802

9 - I

SU –

Roo

t Hal

l Low

er L

evel

Cla

ssro

om R

enov

atio

n\D

raw

ings

\E20

1 - L

OW

ER L

EVEL

PLA

N -

LIG

HTI

NG

.dw

g, 5

/1/2

018

2:41

:06

PM

AutoCAD SHX Text
UP
AutoCAD SHX Text
(36.0 36.0 1.5708 "S" 2.0 0.5 7.0 1.0 84.0 "W" "W" "N" 2.5 0.6875 0.25 "casing1" 1 1 1 1 0.5 5.5 4.0 36.0 6.0 4.0 4.0 5.5 30.0 7.25 1.0 "N" "Y" "Y" "N" "N" "Y" "N" "N" 24.0 24.0 12.0 16.0 1.0 "Y" "N" "W" 2.5 "N" 8.0 2 "Y")
AutoCAD SHX Text
(36.0 36.0 1.5708 "S" 2.0 0.5 7.0 1.0 84.0 "W" "W" "N" 2.5 0.6875 0.25 "casing1" 1 1 1 1 0.5 5.5 4.0 36.0 6.0 4.0 4.0 5.5 30.0 7.25 1.0 "N" "Y" "Y" "N" "N" "Y" "N" "N" 24.0 24.0 12.0 16.0 1.0 "Y" "N" "W" 2.5 "N" 8.0 2 "Y")
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
OF SHEETS
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
U
AutoCAD SHX Text
Facilities Management Department
AutoCAD SHX Text
951 Sycamore Street
AutoCAD SHX Text
Terre Haute, Indiana 47809
AutoCAD SHX Text
Phone: (812) 237-8100 Fax: (812) 237-7630
AutoCAD SHX Text
NDIANA
AutoCAD SHX Text
TATE
AutoCAD SHX Text
NIVERSITY
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
PROPERTY NO.:
AutoCAD SHX Text
5/1/2018
AutoCAD SHX Text
CLASSROOM RENOVATION
AutoCAD SHX Text
ROOT HALL
AutoCAD SHX Text
DA# 18029
AutoCAD SHX Text
732 N. CAPITAL AVE. INDIANAPOLIS, IN 46204 PHONE: (317) 634-4672 FAX: (317) 638-8725
AutoCAD SHX Text
PE60910351
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
No.
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
M
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
E.
AutoCAD SHX Text
L
AutoCAD SHX Text
E
AutoCAD SHX Text
I
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
1/8"=1'-0"
AutoCAD SHX Text
DEW
AutoCAD SHX Text
DEW
AutoCAD SHX Text
DED
AutoCAD SHX Text
LOWER LEVEL PLAN LIGHTING
AutoCAD SHX Text
E201
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
A014
AutoCAD SHX Text
A016B
AutoCAD SHX Text
A016
AutoCAD SHX Text
A020
AutoCAD SHX Text
A003
AutoCAD SHX Text
A015B
AutoCAD SHX Text
A015A
AutoCAD SHX Text
A015
AutoCAD SHX Text
A016A
AutoCAD SHX Text
A017
AutoCAD SHX Text
A019
AutoCAD SHX Text
A022
AutoCAD SHX Text
A018
AutoCAD SHX Text
A04
AutoCAD SHX Text
A023
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
LIGHTING FIXTURE SCHEDULE
Page 13: Evan & Ryan Contractors | Evan & Ryan Contractors

NORTH

LOWER LEVEL PLAN - POWERSCALE: 1/8" = 1'-0"

PLAN NOTES#

1. PROVIDE 120V CIRCUIT AND CONTROL WIRING TO MOTORIZEDPROJECTION SCREEN.

2. COORDINATE DEVICE LOCATION WITH TV.

3. PROVIDE 120V CIRCUIT AND DUPLEX RECEPTACLE AT PROJECTOR.

4. ALL RECEPTACLE CIRCUITS IN THIS ROOM SHALL BE FED FROM EXISTINGCOMPUTER ROOM PANEL.

5. ALL RECEPTACLE CIRCUITS IN THIS ROOM SHALL BE FED FROM EXISTINGUNNAMED PANEL.

6. EXISTING PANEL.

7. EXISTING DEVICES TO REMAIN UNLESS OTHERWISE NOTED.

GENERAL NOTES1. SEE DRAWING E001.

2. COORDINATE DEVICE LOCATIONS WITH MARKERBOARDS, ETC.

RENOVATION LEGENDWORK TO BE INSTALLED

EXISTING WORK TO REMAIN.

(277/480V) 'HBA'

(120/208V) 'LBA-1'

(120/208V) 'LBA-2'COMPUTER ROOMPANEL (120/208V)

UNNAMED PANEL(120/208V)

9

99

59

1111 11+60"TV2

2

2

468

182022

26

25

4

5

PR25

25PR

3

3

6

10

131517

18

16

PR16

16PR

3

3

1214

6

6

TEACHERPODIUM

TEACHERPODIUM

6

6

6

6

6

11

P:\2

018\

1802

9 - I

SU –

Roo

t Hal

l Low

er L

evel

Cla

ssro

om R

enov

atio

n\D

raw

ings

\E21

1 - L

OW

ER L

EVEL

PLA

N -

POW

ER.d

wg,

5/1

/201

8 2:

41:4

1 PM

AutoCAD SHX Text
UP
AutoCAD SHX Text
(36.0 36.0 1.5708 "S" 2.0 0.5 7.0 1.0 84.0 "W" "W" "N" 2.5 0.6875 0.25 "casing1" 1 1 1 1 0.5 5.5 4.0 36.0 6.0 4.0 4.0 5.5 30.0 7.25 1.0 "N" "Y" "Y" "N" "N" "Y" "N" "N" 24.0 24.0 12.0 16.0 1.0 "Y" "N" "W" 2.5 "N" 8.0 2 "Y")
AutoCAD SHX Text
(36.0 36.0 1.5708 "S" 2.0 0.5 7.0 1.0 84.0 "W" "W" "N" 2.5 0.6875 0.25 "casing1" 1 1 1 1 0.5 5.5 4.0 36.0 6.0 4.0 4.0 5.5 30.0 7.25 1.0 "N" "Y" "Y" "N" "N" "Y" "N" "N" 24.0 24.0 12.0 16.0 1.0 "Y" "N" "W" 2.5 "N" 8.0 2 "Y")
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
OF SHEETS
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
U
AutoCAD SHX Text
Facilities Management Department
AutoCAD SHX Text
951 Sycamore Street
AutoCAD SHX Text
Terre Haute, Indiana 47809
AutoCAD SHX Text
Phone: (812) 237-8100 Fax: (812) 237-7630
AutoCAD SHX Text
NDIANA
AutoCAD SHX Text
TATE
AutoCAD SHX Text
NIVERSITY
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
PROPERTY NO.:
AutoCAD SHX Text
5/1/2018
AutoCAD SHX Text
CLASSROOM RENOVATION
AutoCAD SHX Text
ROOT HALL
AutoCAD SHX Text
DA# 18029
AutoCAD SHX Text
732 N. CAPITAL AVE. INDIANAPOLIS, IN 46204 PHONE: (317) 634-4672 FAX: (317) 638-8725
AutoCAD SHX Text
PE60910351
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
No.
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
M
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
E.
AutoCAD SHX Text
L
AutoCAD SHX Text
E
AutoCAD SHX Text
I
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
LOWER LEVEL PLAN POWER
AutoCAD SHX Text
E211
AutoCAD SHX Text
A014
AutoCAD SHX Text
A016B
AutoCAD SHX Text
A016
AutoCAD SHX Text
A020
AutoCAD SHX Text
A003
AutoCAD SHX Text
A015B
AutoCAD SHX Text
A015A
AutoCAD SHX Text
A015
AutoCAD SHX Text
A016A
AutoCAD SHX Text
A017
AutoCAD SHX Text
A019
AutoCAD SHX Text
A022
AutoCAD SHX Text
A018
AutoCAD SHX Text
A04
AutoCAD SHX Text
A023
AutoCAD SHX Text
1/8"=1'-0"
AutoCAD SHX Text
DEW
AutoCAD SHX Text
DEW
AutoCAD SHX Text
DED
Page 14: Evan & Ryan Contractors | Evan & Ryan Contractors

TYPICAL RECESSED FLUORESCENT LIGHTING INSTALLATION

CONDUIT CLAMP AND HANGER

BETWEEN HANGERS (TYP.)HANGER & 8' MAX. SPACING- 3' MAX. FROM BOX TO

6' MAX. LENGTH FLEX CONDUIT

DO NOT SUPPORT

GRID HANGERS

CONDUIT OR BOXFROM CEILING

W/ 3-#12 CONDUCTORS INTO

TYPICAL 2'x4' LAY-IN

PROVIDE CHAIN HANGERS TO

SUSPENSION SYSTEM (TYP.)

TWO PER FIXTURE (TYP.)

T-BAR LAY-IN CEILING

GRID WITH CLIPS PERSECURE FIXTURES TO

RECESSED FLUORESCENTLIGHT FIXTURE (TYP.)

STRUCTURE FOR FIXTURE SUPPORT,

N.E.C. (TYP.)

NOTES:

FIXTURE (TYP.)

STEEL OUTLET BOX -SIZED PER N.E.C. ANDSUPPORTED RIGIDLYFROM STRUCTURE (TYP.)

CONDUIT (TYP.)

18" AFF OR MATCH ADJACENT DEVICE,

BOX RECESSSED IN WALL WITH 1"

UNLESS OTHERWISE NOTED.

4-11/16" SQ. X 2-1/2" DEEP 2-GANG

EXTENSION RING, FLUSH W/ FINISHED WALL.

TECHNOLOGY OUTLET ROUGH-IN DETAIL

PROVIDE ONLY (1) 3/4"C.FOR WALL PHONE.

(NOTE:

IN WALL TO 6" ABOVE CEILING,(2) 1" CONDUITS CONCEALED

WITH PULL STRING.

LONG SWEEPELBOWS

WHEN PULLING CABLES, FILL ONE CONDUITFIRST BEFORE USING OTHER CONDUIT.

FLOOR

LC

ACCESSIBLE CEILING

WALL MINIMUM OF 6" W/ ELBOWS.(EXTEND TO ABOVE ACCESSIBLE CEILING).

PLASTIC BUSHING (TYP.)EXTEND CONDUITS OUT OF

NOTE:

VERIFY WITH WALL CONSTRUCTION.

NO SCALE

NO SCALE

P:\2

018\

1802

9 - I

SU –

Roo

t Hal

l Low

er L

evel

Cla

ssro

om R

enov

atio

n\D

raw

ings

\E40

1 - D

ETAI

LS -

ELEC

TRIC

AL.d

wg,

5/1

/201

8 2:

42:0

7 PM

AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
OF SHEETS
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
U
AutoCAD SHX Text
Facilities Management Department
AutoCAD SHX Text
951 Sycamore Street
AutoCAD SHX Text
Terre Haute, Indiana 47809
AutoCAD SHX Text
Phone: (812) 237-8100 Fax: (812) 237-7630
AutoCAD SHX Text
NDIANA
AutoCAD SHX Text
TATE
AutoCAD SHX Text
NIVERSITY
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
PROPERTY NO.:
AutoCAD SHX Text
5/1/2018
AutoCAD SHX Text
CLASSROOM RENOVATION
AutoCAD SHX Text
ROOT HALL
AutoCAD SHX Text
DA# 18029
AutoCAD SHX Text
732 N. CAPITAL AVE. INDIANAPOLIS, IN 46204 PHONE: (317) 634-4672 FAX: (317) 638-8725
AutoCAD SHX Text
PE60910351
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
No.
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
M
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
E.
AutoCAD SHX Text
L
AutoCAD SHX Text
E
AutoCAD SHX Text
I
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
1/8"=1'-0"
AutoCAD SHX Text
NFS
AutoCAD SHX Text
BE
AutoCAD SHX Text
---
AutoCAD SHX Text
DETAILS - ELECTRICAL
AutoCAD SHX Text
E401
Page 15: Evan & Ryan Contractors | Evan & Ryan Contractors

NORTH

LOWER LEVEL PLAN - TECHNOLOGYSCALE: 1/8" = 1'-0"

PLAN NOTES#

1. COORDINATE DEVICE LOCATION WITH TV.

2. PROVIDE DATA CABLE TO PROJECTOR, PLUS OTHER CABLINGAS INDICATED ON DRAWING T401.

3. EXISTING DEVICES TO REMAIN UNLESS OTHERWISE NOTED.

4. EXISTING FIRE ALARM STROBE TO REMAIN.

5. PROVIDE FIRE ALARM STROBE TO MATCH EXISTING ANDCONNECT TO EXISTING INDICATING CIRCUIT.

6. RELOCATE EXISTING FIRE ALARM STROBE AS NECESSARY TOAVOID NEW MARKER BOARD.

7. EXISTING EMERGENCY NOTIFICATION PHONE TO REMAIN.

8. PROVIDE FIRE ALARM SMOKE DETECTOR TO MATCH EXISTINGAND CONNECT TO EXISTING INITIATING CIRCUIT.

GENERAL NOTES1. SEE DRAWING E001.

2. SEE DRAWING T401 FOR A/V SPECS.

3. ALL VOICE, DATA, AND COAX CABLING SHALL BE FED FROMEXISTING TELECOM ROOM A016B. PROVIDE PATCH PANELSAS REQUIRED.

4. COORDINATE ALL DEVICE LOCATIONS WITH MARKERBOARDS, ETC.

5. SEE DRAWING ED201 FOR TECHNOLOGY DEMOLITION.

RENOVATION LEGENDWORK TO BE INSTALLED

EXISTING WORK TO REMAIN.

(EXISTING TELECOM ROOM)

TV+60"1

6 6 6

PR

PR

PR

PR

2

D

AP

D

2

TEACHERPODIUM

5D/1V

ENS

6 6 6

6 6 6

TEACHERPODIUM

5D/1V

ENS

2

D

D

2

6 6 6

AP

F

F

4

6

ENS

F5

F

F

F

F

8

8

8

8

AP

AP

P:\2

018\

1802

9 - I

SU –

Roo

t Hal

l Low

er L

evel

Cla

ssro

om R

enov

atio

n\D

raw

ings

\T20

1 - L

OW

ER L

EVEL

PLA

N -

TEC

HN

OLO

GY.

dwg,

5/1

/201

8 2:

46:0

3 PM

AutoCAD SHX Text
UP
AutoCAD SHX Text
(36.0 36.0 1.5708 "S" 2.0 0.5 7.0 1.0 84.0 "W" "W" "N" 2.5 0.6875 0.25 "casing1" 1 1 1 1 0.5 5.5 4.0 36.0 6.0 4.0 4.0 5.5 30.0 7.25 1.0 "N" "Y" "Y" "N" "N" "Y" "N" "N" 24.0 24.0 12.0 16.0 1.0 "Y" "N" "W" 2.5 "N" 8.0 2 "Y")
AutoCAD SHX Text
(36.0 36.0 1.5708 "S" 2.0 0.5 7.0 1.0 84.0 "W" "W" "N" 2.5 0.6875 0.25 "casing1" 1 1 1 1 0.5 5.5 4.0 36.0 6.0 4.0 4.0 5.5 30.0 7.25 1.0 "N" "Y" "Y" "N" "N" "Y" "N" "N" 24.0 24.0 12.0 16.0 1.0 "Y" "N" "W" 2.5 "N" 8.0 2 "Y")
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
OF SHEETS
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
U
AutoCAD SHX Text
Facilities Management Department
AutoCAD SHX Text
951 Sycamore Street
AutoCAD SHX Text
Terre Haute, Indiana 47809
AutoCAD SHX Text
Phone: (812) 237-8100 Fax: (812) 237-7630
AutoCAD SHX Text
NDIANA
AutoCAD SHX Text
TATE
AutoCAD SHX Text
NIVERSITY
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
PROPERTY NO.:
AutoCAD SHX Text
5/1/2018
AutoCAD SHX Text
CLASSROOM RENOVATION
AutoCAD SHX Text
ROOT HALL
AutoCAD SHX Text
DA# 18029
AutoCAD SHX Text
732 N. CAPITAL AVE. INDIANAPOLIS, IN 46204 PHONE: (317) 634-4672 FAX: (317) 638-8725
AutoCAD SHX Text
PE60910351
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
No.
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
M
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
E.
AutoCAD SHX Text
L
AutoCAD SHX Text
E
AutoCAD SHX Text
I
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
LOWER LEVEL PLAN TECHNOLOGY
AutoCAD SHX Text
T201
AutoCAD SHX Text
A014
AutoCAD SHX Text
A016B
AutoCAD SHX Text
A016
AutoCAD SHX Text
A020
AutoCAD SHX Text
A003
AutoCAD SHX Text
A015B
AutoCAD SHX Text
A015A
AutoCAD SHX Text
A015
AutoCAD SHX Text
A016A
AutoCAD SHX Text
A017
AutoCAD SHX Text
A019
AutoCAD SHX Text
A022
AutoCAD SHX Text
A018
AutoCAD SHX Text
A04
AutoCAD SHX Text
A023
AutoCAD SHX Text
1/8"=1'-0"
AutoCAD SHX Text
DEW
AutoCAD SHX Text
DEW
AutoCAD SHX Text
DED
Page 16: Evan & Ryan Contractors | Evan & Ryan Contractors

GENERAL NOTES1. THESE DOCUMENTS REPRESENT OWNER INPUT DATED

4/2/2018. VERIFY ALL REQUIREMENTS PRIOR TO BIDDING.

2. SEE DRAWING E001.

ROOM 023

ROOMS 017 & 019

P:\2

018\

1802

9 - I

SU –

Roo

t Hal

l Low

er L

evel

Cla

ssro

om R

enov

atio

n\D

raw

ings

\T40

1 - A

V D

ETAI

LS.d

wg,

5/1

/201

8 2:

39:5

0 PM

AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
OF SHEETS
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
U
AutoCAD SHX Text
Facilities Management Department
AutoCAD SHX Text
951 Sycamore Street
AutoCAD SHX Text
Terre Haute, Indiana 47809
AutoCAD SHX Text
Phone: (812) 237-8100 Fax: (812) 237-7630
AutoCAD SHX Text
NDIANA
AutoCAD SHX Text
TATE
AutoCAD SHX Text
NIVERSITY
AutoCAD SHX Text
FILENAME:
AutoCAD SHX Text
PROPERTY NO.:
AutoCAD SHX Text
5/1/2018
AutoCAD SHX Text
CLASSROOM RENOVATION
AutoCAD SHX Text
ROOT HALL
AutoCAD SHX Text
DA# 18029
AutoCAD SHX Text
732 N. CAPITAL AVE. INDIANAPOLIS, IN 46204 PHONE: (317) 634-4672 FAX: (317) 638-8725
AutoCAD SHX Text
PE60910351
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
No.
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
M
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
E.
AutoCAD SHX Text
L
AutoCAD SHX Text
E
AutoCAD SHX Text
I
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
A/V SPECIFICATIONS - TECHNOLOGY
AutoCAD SHX Text
T401
AutoCAD SHX Text
1/8"=1'-0"
AutoCAD SHX Text
DEW
AutoCAD SHX Text
DEW
AutoCAD SHX Text
DED