ex5/ex5p - intercoms r us pdf/xpr ex5p keypad.pdf · user code memory locations are assigned to...
TRANSCRIPT
EX5 EX5P
: Standalone Keypad: 99 User Codes : Input Voltage 12/24V AC/DC: Switching Regulator: Current consumption : Standby 30mA, maximum 130mA.
: Standalone Keypad with Integrated Proximity: Reads EM Cards, with Read range 3-12 Cms: 99 User Codes/Tag:: Double Security with Code + Tag or Tag + Tag::
Single Security with Code or Tag
Input Voltage 12V AC/DCLinear Power supply.
: Current consumption : Standby 20mA, maximum 180mA.
Common
: Backlit keys (metal / plastic): User Code length:1- 8 digits: 2 relays (R1: 10A/24V DC /120V AC; R2: 2A/24V DC/120AC): 2 Push buttons to operate relays: Entry codes can be programmed to activate either one of the relays or both relays together: 2 Free tension LEDs Red & Green: Yellow LED (and buzzer sound) indicates Key Press function : 30 sec lockout after 8 invalid codes: Additional slave readers can be connected via bi directional CODIX bus: EEPROM prevents data loss during power failure
EX5 EX5P
::: Fonctionne sur 12/24V CC/CA:
Clavier autonome99 codes d'utilisateur
Consommation au repos: 30mA, Maximum: 130mA
Régulateur de commutation:
: Clavier autonome avec lecteur de proximité intégré: Lecture badges EM (3-12 Cm): 99 badges/code utilisateurs : Simple sécurité : code ou badge: Double sécurité : code + badge ou badge + badge : Fonctionne sur 12V CC/CA: Alimentation linéaire: Consommation au repos:20mA, Maximum:180mA
Commun
: Touches retro-éclair'ees (metal / plastique): Longueur du code utilisateur : 1 à 8 digits: 2relais, (1x10A, 1x2A) en mode marche /arret(00) ou impulsionnel (01 'a 99sec): 2 boutons de sortie: Possibilité d'assigner le relais 1 et/ou relais 2 à un code utilisateur/badge: 2Led libres de tension (rouge et verte): Led jaune d'indication avec sonorisation: 30 sec de verrouillage après 8 codes incorrects: Possibilité de raccorder des lecteurs ( à code / proximité ) via le bus CODIX: Memoire EEPROM sauvegarde Les donnees
Mounting MontageUK FR
1. 2. 4.
CableCable
Ø6.0
30m
m
CableCable
Ø6.0
30m
m
43B 3.
7.
3 (8 x 30 CSK)
5. 6. 8.
2 (M3 x 6mm)security screw1. 2. 3. 4.
5
5
EX5: 52B / 52G /72C EX5P: 53B /53G /73C
6.
3 (8 x 30mm CSK)
5. 7.
2 (M3 x 6mm)
ENTRIX 1 EX5P
EX5/EX5P
1. 2. 3. 4.
EX5:102A/ B / G EX5-P:103A/ B/ G
30
mm
Ø6.0
CableCable
5. 6. 7.
3 (8 x 30mm CSK)
4 (M3 x 6mm)
ENTRIX 2
Mounting MontageUK FR
UK FR PCB Overview Pr sentation de l’ lectroniqueé é
UK FRConnecting Strike or EM Lock to relays Connexion d'une gâche aux relais
DCPowerSupply
_
+
NO
NC
CRelay TerminalBorniers relais
Electro Magnetic LockVentose
IN4001
External DC Power Supply for EM LockAlimentation CC eterne Pour VENTOUSE
ACPowerSupply
~
NO
NC
C
StrikeGache
External AC Power Supply for strikeAlimentation CA eterne Pour GACHE
~1k / 1/2W + 470nF
Note: Strike can be connected to DC. Une gâche peut être connectée à une alimentation DC.
Max. 50m
12/24V AC/DC
Do not apply any voltage to the CODIX BUS.
N'appliquer aucune tension au bus CODIX.
Jumper openedCavalier ouvert
Jumper closedCavalier fermé
EX5P
Relay TerminalBorniers relais
EX5P
12V AC/DC LED
G
DG
/PS/0
00
9IS
-01
LED
R
DG
/PS/0
00
9IS
-01
EX
5P
Max. 50m
Connecting voltage free LEDs Connexion des Leds libres de tension
12V
+
-LED
+12V
12V DC (CC) 12V AC (CA)
LED 12V ~
Diode IN4001
+
-
LED
24V DC (CC)1k / 1/2W
+
-LED
24V AC (CA)1k / 1/2W
+
-
24V
UK
-
+
-
+24V
-24V ~
+
-
ENTRIX 3
FR
Connecting LEDs for relay status Connexion des Leds pour indiquer l’état du relaisUK FR
DCPowerSupply
_
+
NO
NC
C
IN4001
ACPowerSupply
~
NO
NC
C
~1k / 1/2W + 470nF
_+
LEDG/LEDR _+
LEDG/LEDR
IN4001
Tamp
(NC)
Tamper switch Switch d'autoprotectionUK FR
Exit button Bouton de sortieUK FR
PB1
PB2
GND
Exit button (Relay 1) Bouton sortie 1 actionne le relais 1
Exit Button (Relay 2)Bouton sortie 2 actionne le relais 2
EX5
External DC Power Supply for EM LockAlimentation CC eterne Pour VENTOUSE
External AC Power Supply for strikeAlimentation CA eterne Pour GACHE
Relay TerminalBorniers relais
Relay TerminalBorniers relais
Electro Magnetic LockVentose
StrikeGache
PB2
PB1
GND
Exit button (Relay 2) Bouton sortie 1 actionne le relais 2
Exit Button (Relay 1)Bouton sortie 2 actionne le relais 1
EX5P
EX5P
Connecting CODIX peripherals CODIXConnexion des périphériquesUK
ENTRIX 4
FR
EX5
+9V
DATA
CO
DIX
BU
S
GND
+9V
DATA
GND
+9V
DATA
GND
INOX
MINI
VKP
a.
Max. 200m
MINIEX5/EX5P
Max. 100m
b.
Cable Distance with readers Distance du câble avec les lecteursUK FR
EX5P
+9V
DATA
CO
DIX
BU
S
GND
+9V
DATA
GND
INOX
MINI
VKP
+9V
DATA
GND
+9V
DATA
GND+9V
DATA
GND
Redefining Master code Redéfinition du code Maître
1.
2.
4. 000
3.
5. A+ 6. B
Ex: 000 + 2578 + A + BEx (nouveau code maître 2578) : 000 + 2578 + A + B
Disconnect power Débranchez l'alimentation
Reconnect powerRebranchez l'alimentation
Beep Beep ... + Yellow LED blinksBip Bip ... + Led jaune clignote
Yellow LED ON + Long beepLED jaune ALLUMEE + Long bip
New Master codeNouveau Code Maitre
Beep BeepBip Bip
Yellow LED OFFLED jaune ETEINTE
UK FR
It is possible to redefine and restore the default setting, if the Master code is forgotten.Pour changer le code Maître ou en cas de perte de ce dernier, il est possible de le redéfinir suivant les étapes ci-dessous
EX5P
EX5/EX5P
MINI
INOX
LR
DG
DG
/PS/0
00
9IS
-01
LR
DR
DG
/PS/0
00
9IS
-01
EX
5P
PROGRAMMING FLOW CHARTUK
ENTRIX 5
Master Code
Press 000
Validate By
Press B
1 Small Beep + Yellow Led ON
Programming Mode Yellow LED ON
ChangeMaster Code
AssignUser Code
AssignRelay Timing
Assign outputs To User Code
DeleteAll Codes
DeleteSingle Code
Normal Mode Yellow LED OFF
Press 0 Press 0Press
1Press
2Press 8Press 3 Press 9
Press00
Memorylocation
from (01-99)
Relay1
Memorylocation
from (01-99)Press 99
Relay2
Memorylocation
from (01-99)
NewMaster Code (1 to 8 digit)
Enter Code Or
Present cardOr
Present Tag
01-99 PulseMode
'00' ON/OFF
Relay2
Relay1
Relay1&2
Press2
Press1
Press1&2
Validate
A
Multiple small beeps+
Yellow LED blinks rapidly
Invalid Entry
Multiple small beeps+
Yellow LED blinks
Two Beeps
Quit Programming Mode
Press B
NextProgramming
Invalid Entry Validation Ok
Memory Position(01 - 99)
User codes are stored at Memory location (01 to 99).Master Code is stored at Memory location (00) which is reserved.
User Code Memory locations are assigned to activate Relay 1 & Relay 2.
Redefine Master codeOr
Change Master codeOr
Master code lost
Switch “OFF” Power Supply.
Put Jumper in closed position.
Switch ON Power Supply.
Beep Beep… + Yellow LED “ON”.
Put the Jumper in Open position.
Yellow LED “ON” + Long Beep.
For Default Master Code Press 000 + 000 + A + B
For another Master Code Press 000 + 12345 + A + B
New Master code set to 12345
EX5P
SCHEMA DE PROGRAMMATIONFR
ENTRIX 6
Code maître
Composez 000
Validez par
Composez B
1 bip court + Led jaune allumée
Mode programmation Led jaune allumée
Changer le code maître
Assigner un code utilisateur
Configurez la temporisation
Assigner les relais au code utilisateur
Effacer un code utilisateur
Effacer tous les utilisateurs
Mode normal Led jaune étteinte
Composez 0 Composez 0Composez
1Composez 8Composez 3 Composez 9
Composez 00Position de la
mémoire(de 01 à 99)
Relais1
Position de la mémoire
(de 01 à 99)Composez 99
Relais2
Position de la mémoire
(de 01 à 99)
Nouveaucode maître (1 à 8 digits)
Composez le codeOu
Présentez le carteOu
Présentez le badge
Mode impulsionnel (de 01 à 99)
Mode marche/arrêt ( 00 )
Relais2
Relais1
Relais1&2
Compo-sez2
Compo-sez1
Compo-sez1&2
Validez par
A
Multiples bips courts+
Led jaune clignote
Fausse manipulation
Multiples bips courts+
Led jaune clignote
Deux bips
Quitter le mode programmation
Composez B
Prochaineprogrammation
Confirmationréussite
Position mémoire(01 to 99)
Un code utilisateur est enregistré dans une position mémoire (01 à 99).Le code mâitre se trouve en position memoire 00.
On peut assigner une position mémoire pour activer relais 1 et/ou relais 2
Redefinition / Modification
/ ou perte du code maître
Couper l'allimentation
Positionnez le cavalier en position fermé
Connectez l'alimentation
Deux bips + led jaune allumée
Positionnez le cavalier en position ouverte
Led jaune allumée+long bip
Composez le code maître par defaut 000 +000 + a+b
Composez un autre code maître 000 + 12345 + a + b
Nouveau code programmé est 12345
Composez2
Programming the Keypad Programmation du clavierUK FR
1.1 Important Note 1.1 RemarqueUK FR
- User Code (1 to 8 digits) are stored in memory locations from 01- 99- Any user code memory location can activate Relay 1 and / or Relay 2.- Examples below use the default Master Code '000' - For security reasons it is recommended to change the default Master Code as in the following example;
000 + B + 000 + 5894 + A + B.- In case Master Code is lost or forgotten, refer Redefine the Master Code section.- If User wants to replace his code (say, 123) with a Tag, it can be programmed as shown in the example below:
EX5 : By presenting a tag in front of the proximity reader wired to the Codix terminal block of the EX5.
EX5P: By presenting a tag in front of the EX5P keypad or of a proximity reader wired to the Codix terminal block of the EX5P
- Une position mémoire ( de 01 à 99 ) est l'endroit de la mémoire ou l'on va mémoriser le code utilisateur ( de 1 à 8 digits )- Une position mémoire peut actionner le relais 1 et/ou le relais 2- Les exemples ci-dessous utilisent le code maître par défaut '000- Pour des raisons de sécurité il est conseillé de changer ce code (ex : 5894)
000 + B + 000 + 5894 + A + B- En cas de perte du code maître : voir Redéfinition du code maître- Les exemples ci-dessous utilisent le code utilisateur 123 mais on pourrait maginer de remplacer ce dernier par un badge.
EX5 : En présentant un badge en face du lecteur de proximité raccordé aux bornes CODIX de l'EX5.
EX5P: En présentant le badge devant les touches du clavier ou en raccordant un lecteur de proximité au bus CODIX de l'EX5P.
EX5P
Faussemanipulation
ENTRIX 7
1.2 Programming 1.2 Aide programmationUK FR
1.3 Using the code or tag 1.3 Utilisation du code UK FR
1.2.1 To assign a User code to a Memory position.
Ex: Code 123 to a Memory Position 05 000 + B + 0 + 05 + 123 + A + B
1.2.2 Assigning a memory position to a relay
Ex: Memory location 05 to activate relay 1 000 + B + 3 + 05 + 1 + A + B
Ex: Memory Location 05 to activate relay 2 000 + B + 3 + 05 + 2 + A
Ex: Memory Location 05 to activate both relay 1 and relay 2 000 + B + 3 + 05 + 1 + 2 + A + B
Note: Examples 1.2.1 and 1.2.2 can be combined without leaving programming mode, e.g. to assign a user code 123 at memory location 05 and to activate relay 1, the combination can be programmed as below. 000+B+0+05+123+A+3+05+1+A (for relay 1)+B
1.2.3 Programming for the Relay Status
Relay 1: ON/OFF (Latch) Mode (00)000 + B + 1+ 00 + A + B
Relay 2: Pulse Mode 05 Seconds000 + B + 2 + 05 + A + B
1) Users can either - Press the user code and validate by pressing A (EX : 123 +A ) - Present a Card Or Tag in front of a keyad(EX5P) or a Proximity reader connected by the CODIX bus.
EX5-P can be programmed as follows - Code + (Tag Or Card) - Code Or Tag) + (Code Or Tag)
1.2.1 Assigner un code utilisateur à une position mémoire.
Ex: Code 123 , position mémoire 05 000 + b + 0 + 05 + 123 + A + B
1.2.2 Assigner une position mémoire à un relais.
Ex: Position mémoire 05, relais 1 000 + B + 3 + 05 + 1 + A + B
Ex: Position mémoire 05, relais 2 000 + B + 3 + 05 + 2 + A + B
Ex: Position mémoire 05, relais 1 et relais 2 000 + B + 3 + 05 + 1 + 2 + A + B
Remarque: Le point 1 et 2 peuvent être combinés sans devoir sortir de programmation (ex : assigner le code 123 à la position mémoire 05, cette dernière actionne le relais 1) 000 + B + 0 + 05 + 123 + A + 3 + 05 + 1 + A + B
1.2.3 Programmer la temporisation du relais
Relais 1: Mode marche/arrêt ( 00 ) 000 + B + 1 + 00 + A + B
Relais 2: Temporisation de 5 secondes ( 03 ) 000 + B + 2 + 03 + A + B
1) Les utilisateurs devront soit : - Introduire le code et valider par A ( ex : 123 A ) - Présenter le badge devant les touches du clavier (EX5P) ou le lecteur de proximité raccordé au bus CODIX
L'EX5P permet d'assigner à une position mémoire - Un code + Badge - Un Badge + Badge
2.0 Double Security (EX5-P only) 2.0 Double sécurité (EX5P)UK FR
2.1.1 To assign Tag 1 + a User code in a memory location
Ex: Tag + Code 123 in memory location 05 000+B+0+05 + Present Tag 1+ 123 +A+B
2.1.2 To assign Tag 1 + Tag 2 in memory location 05
000+B+0+05 + Present Tag 1+ Present Tag 2 +A+B
2.1.1 Assigner un Badge(1) + code utilisateur à une position mémoire.
Ex: Code 123 , position mémoire 05 000 + B + 0 + 05 + 123 + présenter le Badge(1) + A + B
2.1.2 Assigner un Badge(1) + Badge(2) à une position mémoire.(position mémoire 05)
000 + B + 0 + 05 + présenter le Badge(1) + présenter le Badge(2) + A + B
2.2 Using code and / or tags .2 Utilisation du code 2UK FR
Code + Tag:- Code + Tag (Press a Code + Validate with A + Present a Tag) 123 + A + Present Tag- Present a Tag + Press a Code + Validate with A Present the Tag + 123 +ATag +Tag:- Tag1+Tag 2 (Present Tag 1 and then present Tag 2)- Tag2 + Tag1 (Present Tag 2 and then present Tag 1) Tag2 + Tag 1
Les utilisateurs devront soit:- Code + Badge ( introduire le code + Valider par A + Présenter le Badge ) 123 + A + Presenter Badge(1) ou Présenter Badge(1) + 123 + A- Code + Badge ( introduire le code + Valider par A + Présenter le Badge ) Presenter Badge(1) + Presenter Badge(2) ou Présenter Badge(2) + Presenter Badge(1)
EX5P
2.1 Programming 2.1 Aide programmationUK FR
ENTRIX 8
PB1
GND
PB2
NC
C
NO
12/2
4V
AC
/DC
RELA
Y1
+_ LG
+_
+9V
DATA
GND
TAMP
NC
C
NO
LR
RELA
Y2
StrikeGâche
Alarm CKT
Red/Rouge
White/ Blanc
Black/ Noir
Green/ Vert
Blue/ Bleu
Gre
y/
Gri
s(N
C)O
ran
ge/
Ora
ng
e(N
C)
ReaderMINI
GND
Signal
Quit/Quitter
Single Door connection diagram/ Schéma de câblage pour une porte
PS2
PO
WER
SU
PP
LY
IN4001
Yellow
/Ja
un
e(N
C)
+_
GND
DATA
+9V
12V
AC
/DC
+
_LEDR
+_
TAMP
NC
C
NO
RELA
Y1 NC
C
NO
PB2
GND
PB1
LEDG
RELA
Y2
ReaderMINI
+
_
Alarm CKT
PS2
POWER SUPPLY
3.0 Application Diagram For EX5 3.0 Diagramme d'application EX5UK FR
NC: Not UsedPas Utilise
4.0 Application Diagram For EX5P 4.0 Diagramme d'application EX5PUK FR
NC: Not UsedPas Utilise
Single Door connection diagram/ Schéma de câblage pour une porte
XPR/D
G/I
M/0
07
0IS
-01
Quit/ Quitter
Warranty : XPR warrants its products to be free from defects in material and workmanship for 24 months from the date of shipment. The product is to be installed in accordance with XPR's instructions and the unit should not be modified or tampered with. XPR does not assume any responsibility for damages arising from misuse of the product. XPR's sole responsibility is limited to the repair or replacement when the product is sent to XPR's facility.
Garantie : XPR garantit ses produits au regard des défauts matériels et ce pendant 24 mois à compter de la date d'expédition. Le produit doit être installé conformément aux instructions de XPR et l'unité ne doit pas être modifiée ou manipulée. XPR n'endosse aucune responsabilité pour les dommages résultant d'une mauvaise utilisation du produit. La responsabilité de XPR se limite à la réparation ou à son remplacement, le produit ayant été retourné à XPR.
EX5P
Red/Rouge
White/ Blanc
Black/ Noir
StrikeGâche
Gre
en
/V
ert
Blu
e/
Ble
u
Gre
y/
Gri
s(N
C)
Ora
ng
e/
Ora
ng
e(N
C)
Yellow
/Ja
un
e(N
C)
PS2
POWER SUPPLY
PS2
POWER SUPPLY
IN4001
Signal
GND
GND
www.xprsec.comAn ISO 9001:2000Certified Company