Exhibit II Equipment Lists & Sample Service Sheet Site 1 - CBJTC Post Headquarters: Bldg. 2300 - 3 pages Site 2 - CBJTC CSMS Buildings: Bldg. 4100-3 pages Bldg. 4104-3 pages Bldg. 4105-2 pages Bldg. 4106-1 pages Bldg. 4114-1 page Sample Service Sheet - 2 pages Note: Equipment specific Service sheets for equipment and sites will be available at the mandatory site visit.

Upload: hoangtruc

Post on 29-Apr-2018

228 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Exhibit II - MyFlorida.com Exhibit II Equipment Lists & Sample Service Sheet ... Trane : CCDB : AHU-S ; ... CSHC December 2, 2011 : 2 : I:

Exhibit II Equipment Lists & Sample Service Sheet

Site 1 - CBJTC Post Headquarters:

Bldg. 2300 - 3 pages

Site 2 - CBJTC CSMS Buildings:

Bldg. 4100-3 pages Bldg. 4104-3 pages Bldg. 4105-2 pages Bldg. 4106-1 pages Bldg. 4114-1 page

Sample Service Sheet - 2 pages Note: Equipment specific Service sheets for equipment and sites will be available at the mandatory site visit.

Page 2: Exhibit II - MyFlorida.com Exhibit II Equipment Lists & Sample Service Sheet ... Trane : CCDB : AHU-S ; ... CSHC December 2, 2011 : 2 : I:

CBJTC Post HQ Building 2300 Exhibit II -Covered Equipment List Site 1

IEQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEL ISERIAL NUMBER I

AIR HANDLERS

AHU-1 Central Station Air Handler

with VFD, 0-15 HP

Carrier 39MN06C0190 S0780UOS016

AHU-2 Central Station Air Handler

with VFD, 0-15 HP

Carrier 39MN06C0190 708UOS018

AHU-3 Central Station Air Handler

with VFD, 0-15 HP

Carrier 39MN06C0190 708UOS019

AHU-4 Central Station Air Handler Trane CCDB

AHU-S Central Station Air Handler

with VFD, 0-15 HP

Trane CCDB

AHU-6 Central Station Air Handler Trane CCDB

AHU-7 Central Station Air Handler Carrier 39MN06C0190 S078US021

AHU-8 Central Station Air Handler Carrier 39MN06C0190 S078US022

SERVICE FREqUENCY

Operationals

Filter Changes

Comprehensive

TIMES PER YR

4

6

1

SPLIT SYSTEM

SS-l Split System Heat Pump Trane

SS-2 Split System Heat Pump York

SS-3 Split System Heat Pump Goodman

SERVICE FREqUENCY TIMES PER YR

Operationals 4

Filter Changes 6

Comprehensives 1

Condenser Coil Cleaning 1

CBJTC August 12, 2011

1

Page 3: Exhibit II - MyFlorida.com Exhibit II Equipment Lists & Sample Service Sheet ... Trane : CCDB : AHU-S ; ... CSHC December 2, 2011 : 2 : I:

CBJTC Post HQ Building 2300 Exhibit II -Covered Equipment List Site 1

I EQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE ~ MODEL ISERIAL NUMBER I PUMPS

P-1 Circulating Pump Bell & Gossett 1510 C057694-01A80

P-2 Condenser Water Pump Bell & Gossett 2BC

P-3 Hot Water Pump Bell & Gossett 11/4BC

SERVICE FREQUENCY TIMES PER YR

Operationals 4

Comprehensives 1

CHILLER

IAC-1 I Water Cooled Chiller I Carrier I 30HXCl06 I 0508Q08739 I

SERVICE FREQUENCY TIMES PER YR

Operationals 4

Comprehensives 1

Chiller Tube Brushing 1

MISC EQUIPMENT

CT-1 Cooling Tower with Strainer I Marley 4799-1000 I HWB-1 Hot Water Boiler I Burnham PF504 I 7571160

SERVICE FREQUENCY TIMES PER YEAR

Operationals 4

Comprehensives 1

CBJTC August 12, 2011

2

Page 4: Exhibit II - MyFlorida.com Exhibit II Equipment Lists & Sample Service Sheet ... Trane : CCDB : AHU-S ; ... CSHC December 2, 2011 : 2 : I:

CBJTC Post HQ Building 2300

IEQUIPMENT # I EQUIPMENT TYPE I Exhibit II -Covered Equipment List Site 1 MANAFACTURE I MODEL I~SE-R-IA-l-N-U-M-B-E-R""I

CONTROLS

IDDC-l I Building Automation System I Johnson Controls I Metasys G-l I I

1 Network Application Engine (NAE-4s) level one controller

13 Field Equipment controllers level two controller

26 Variable Air Volume Modular Assembly

Variable Drive

15 I Variable Drive I I I I

SERVICE FREQUENCY TIMES PER YEAR

Operationals 4

Comprehensives 1

CBHC August 12, 2011

3

Page 5: Exhibit II - MyFlorida.com Exhibit II Equipment Lists & Sample Service Sheet ... Trane : CCDB : AHU-S ; ... CSHC December 2, 2011 : 2 : I:

CBJTC - CSMS ADMIN BLDG 4100 Exhibit II - Coverd Equipment List Site 2

IEQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE ~ MODel ISERIAL NUMBER I AIR HANDLERS

AHU-1 Air Handler Unit, Return York XTl-102X051-FAKA046A

AHU-2 Air Handler Unit, Return York XTl-084X075-FA1A046A

SERVICE REQUIRED TIMES PER YR

Operationals 4

Filter Changes 4

Evaporator Coil Cleaning 1 Comprehensive 1

SPLIT SYSTEM

155-1 Split System 0-15TI I I I I

SERVICE REQUIRED TIMES PERYR

Operationals 4

Filter Changes 4

Comprehensives 1 Condenser Coil Cleaning 1

PUMPS

P-1 Circulating Pump B+G 1510

P-2 Circulating Pump B+G 1510

SERVICE REQUIRED TIMES PERYR

Operationals 4

Comprehensives 1

CBJTC December 2, 2011

1

Page 6: Exhibit II - MyFlorida.com Exhibit II Equipment Lists & Sample Service Sheet ... Trane : CCDB : AHU-S ; ... CSHC December 2, 2011 : 2 : I:

CBJTC - CSMS ADMIN BLDG 4100 Exhibit II - Coverd Equipment List Site 2

~ EQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEL ISERIAL NUMBER I CHILLER

IAC-1 I Air Cooled Chiller I York I YCA10060EC46X I I

HEATERS

SERVICE REQUIRED

Operationals

Comprehensives

Coil Cleaning

Oil Analysis

TIMES PERYR

4

1

1

1

HG-1 Heater, Gas Infrared Robert Gordon

HG-2 Heater, Gas Infrared Robert Gordon

HG-3 Heater, Gas Infrared Robert Gordon

SERVICE REQUIRED TIMES PER YEAR

Operationals 4

Comprehensives 1

CONTROLS

1 Building Automation System Metasys

C-1 VMA Controller (QTY 13) Johnson Control

C-2 DX-1900 Controller (QTY 1) Johnson Control

C-3 MIG Controller (OTY 1) Johnson Control

C-4 UNT Controller (OTY 1) Johnson Control

SERVICE REQUIRED Times PerYr

Comprehensive 1

Operationals 4

CBHC December 2, 2011

2

Page 7: Exhibit II - MyFlorida.com Exhibit II Equipment Lists & Sample Service Sheet ... Trane : CCDB : AHU-S ; ... CSHC December 2, 2011 : 2 : I:

CBJTC - CSMS ADMIN BLDG 4100 Exhibit 1\ - Coverd Equipment List Site 2

r EQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEL ISERIAL NUMBER I EXHAUST FANS EF-1 Ceiling Mounted Exhaust Fan Greenheck 850-90-4

EF-2 Ceiling Mounted Exhaust Fan Greenheck 850-120-4

EF-3 Ceiling Mounted Exhaust Fan Greenheck 5BE-3H24-S

SERVICE REQUIRED TIMES PER YEAR

Operationals 2

VAVBOX

IVBX-1 VAV Box (OTY 7) TraneI I I I I

SERVICE REQUIRED TIMES PERYR

Operationals 4

Comprehensives 1

Filter Changes 6

CBJTC December 2, 2011

3

Page 8: Exhibit II - MyFlorida.com Exhibit II Equipment Lists & Sample Service Sheet ... Trane : CCDB : AHU-S ; ... CSHC December 2, 2011 : 2 : I:

CBJTC - CSMS Allied Trades BLDG 4104 Exhibit" - Coverd Equipment List - Site 2

IEQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEl ISERIAL NUMBER I AIR HANDLERS

I IIAHU-1 I Air Handler Unit, Mixed Vari Volume 1 10-40HP I SERVICE REQUIRED TIMES PERYR

Operationals 4

Filter Changes 4

Evaporator Coil Cleaning 1

Comprehensive 1

AIR HANDLER

IAHU-2 IAir Handler Unit, Mixed Const Vol (QTY 5) I I 10HP 1 I

SERVICE REQUIRED TIMES PERYR

Operationals 4

Filter Changes 4

Comprehensives 1

SPLIT SYSTEM

ISS-1 I Split System (QTY 2) I 1 0-lST I 1

SERVICE REQUIRED TIMES PER YR

Operationals 4

Filter Changes 4

Condenser Coil Cleaning 1

Comprehensive 1

CBJTC December 2, 2011

1

Page 9: Exhibit II - MyFlorida.com Exhibit II Equipment Lists & Sample Service Sheet ... Trane : CCDB : AHU-S ; ... CSHC December 2, 2011 : 2 : I:

CBJTC - CSMS Allied Trades BLDG 4104 Exhibit II - Coverd EauiDment List - Site 2

EQUIPMENT # EQUIPMENT TYPE MANAFACTURE I MODEL SERIAL NUMBER

AIR COMPRESSOR

IAC-1 Air Compressor, Commercial 1 Commercial I 5-20HPI I I

SERVICE REQUIRED TIMES PER YR Operationals 4

Comprehensives 1

AIR COMPRESSOR

IAC-1 Air Compressor, Industrial (QTY 3) Industrial 76-125 HPI I I I I SERVICE REQUIRED TIMES PER YR

Preventive Maintenance 1

Operationals 4

Comprehensives 1

HEATERS

IHG-1 Heater, Gas Infrared (QTY 11) Robert GordonI I I I I

SERVICE REQUIRED TIMES PER YEAR Operationals 4

Comprehensives 1

CONTROLS

IC-4 UNT Controller (QTY 1) Johnson Control ASC1 I I I I

SERVICE REQUIRED Times PerYr Comprehensive 1

Operationals 4

CSHC December 2, 2011

2

Page 10: Exhibit II - MyFlorida.com Exhibit II Equipment Lists & Sample Service Sheet ... Trane : CCDB : AHU-S ; ... CSHC December 2, 2011 : 2 : I:

IEQUIPMENT # I EQUIPMENT TYPE

CBJTC - CSMS Allied Trades BLDG 4104 Exhibit II - Coverd Equipment List - Site 2

I MANAFACTURE I MODEL ISERIAL NUMBER I EXHAUST FANS

IEF-l I Wall Mounted Exhaust Fan (OTY 2) I I O-SHP I I

SERVICE REQUIRED TIMES PER YEAR

Operationals 2

EXHAUST FANS

IVAF-l Vane Axial Fan 3FT DiaI I I I I SERVICE REQUIRED Times Per Yr

Comprehensive 1

Operationals 4

VARIABLE DRIVE

IVD-l I Variable Spd Drive (Mech Lg) I Mech-Lg I I I

SERVICE REQUIRED Times PerYr

Comprehensive 1 Operationals 4

CBJTC December 2, 2011

3

Page 11: Exhibit II - MyFlorida.com Exhibit II Equipment Lists & Sample Service Sheet ... Trane : CCDB : AHU-S ; ... CSHC December 2, 2011 : 2 : I:

CBJTC - CSMS Electronics BLDG 4105 Exhibit II - Coverd Equipment List Site 2

IEQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEL ISERIAL NUMBER I

AIR HANDLERS AHU-1 Air Handler Unit Mixed, Const Volume I 10HP

AHU-2 Air Handler Unit, Mixed Vari Volume I 10-40HP

SERVICE REQUIRED TIMES PER YR

Operationals 4

Filter Changes 4

Evaporator Coil Cleaning 1 Comprehensive 1

AIR HANDLER

IAHU-3 IAir Handler Unit, 100% OSA Const volumel I 10HP I I SERVICE REQUIRED TIMES PER YR

Operationals 4

Filter Changes 4

Comprehensives 1

SPLIT SYSTEM

155-1 Split System 0-lSTI I I I I

SERVICE REQUIRED TIMES PER YR

Operationals 4 Filter Changes 4

Comprehensives 1

CBJTC December 2, 2011

1

Page 12: Exhibit II - MyFlorida.com Exhibit II Equipment Lists & Sample Service Sheet ... Trane : CCDB : AHU-S ; ... CSHC December 2, 2011 : 2 : I:

I EQUIPMENT # I EQUIPMENT TYPE

CBJTC - CSMS Electronics BLDG 4105 Exhibit II - Coverd Equipment List Site 2

I MANAFACTURE I MODEL ISERIAL NUMBER I HEATERS

HG-1

HG-2 I I

Heater, Gas Infrared

Heater, Gas Infrared I I

Robert Gordon

Robert Gordon

SERVICE REQUIRED TIMES PER YEAR

Operationals 4

Comprehensives 1

CONTROLS

IC-4 I UNT Controller (QTY 1) I Johnson Control I ASC 1 1

SERVICE REQUIRED Times PerYr

Comprehensive 1

Operationals 4

EXHAUST FANS

EF-1 Wall Mounted Exhaust Fan I O-SHP

VAF-1 Vane Axial Fan I SFT Dia

SERVICE REQUIRED TIMES PER YEAR

Operationals 2

VARIABLE DRIVE

I I IIVD-1 1 Variable Spd Drive (Mech Sm) Mech-Sm 1

SERVICE REQUIRED Times PerYr

Comprehensive 1

Operationals 4

CBJTC December 2, 2011

2

Page 13: Exhibit II - MyFlorida.com Exhibit II Equipment Lists & Sample Service Sheet ... Trane : CCDB : AHU-S ; ... CSHC December 2, 2011 : 2 : I:

IEQUIPMENT # I EQUIPMENT TYPE

CBJTC ­ CSMS Auto Service BLDG 4106 Exhibit II - Coverd Equipment List Site 2

I MANAFACTURE I MODEl ISERIAl NUMBER I AIR COMPRESSOR

IAC-1 I Air Compressor, Commercial (QTY 2) I Commercial I S-20HP I I

SERVICE REQUIRED TIMES PER YEAR

Operationals 4 Comprehensives 1

HEATERS

IHG-1 Heater, Gas Infrared (QTY 2) 1 Robert Gordon I 1 1I

SERVICE REQUIRED TIMES PER YEAR

Operationals 4 Comprehensives 1

CONTROLS

IC-1 UNT Controller Johnson Control ASC II I I I

SERVICE REQUIRED Times PerYr

Comprehensive 1 Operationals 4

SPLIT SYSTEM

155-1 1 Split System (QTY 2) I I 0-lST I I

SERVICE REQUIRED TIMES PER YR

Operationals 4

Filter Changes 4

Condenser Coil Cleaning 1 Comprehensive 1

CBJTC December 2, 2011

1

Page 14: Exhibit II - MyFlorida.com Exhibit II Equipment Lists & Sample Service Sheet ... Trane : CCDB : AHU-S ; ... CSHC December 2, 2011 : 2 : I:

CBJTC - CSMS Storage BLDG 4114 Exhibit II -Coverd Equipment List Site 2

IEQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEL ISERIAl NUMBER I EXHAUST FANS

EF-l

EF-2

Wall Mounted Exhaust Fan

Wall Mounted Exhaust Fan

SERVICE REQUIRED TIMES PERYR

Operationals 4

Comprehensive 1

HEATER

IUH-l Unit Heater I I I I I

SERVICE REQUIRED TIMES PER YR

Operationals 4

Condenser Coil Cleaning 1

CBJTC December 2,2011

1

Page 15: Exhibit II - MyFlorida.com Exhibit II Equipment Lists & Sample Service Sheet ... Trane : CCDB : AHU-S ; ... CSHC December 2, 2011 : 2 : I:

0

Sample Service Sheet

> >J::. ..... l0­

t: OJ> 0 -elo­ ro~ ro

I :JSample -Type of Equipment OJ c:e>­Comprehensives

Contact customer representative for performance issues X Check starter and contactor X Check and tighten electrical connections X Inspect pilot and safeties (as applicable) X Check flame quality X Check coil conditions X Check filter condition X Check and clean condensate pan and drain If accessible X Check safety control set points X Check damper operation and lubricate as required X Change belt(s) X LnecK vaIVe{S} }\

Check and lubricate fan and motor bearings X Check for proper fan rotation X Check condition of blower assembly X Check for unusual noises, vibration and wear Report recommendations X Check overall condition of unit X Clean area around equipment X Complete any required maintenance checklists, report observations to

Xappropriate customer representative

Operationals Complete any required maintenance checklists, report observations to

appropriate customer representative X Clean area around equipment X

Check overall condition of unit X

Check for unusual noises, vibration and wear Report recommendations X Check fan operation X Visually Inspect damper(s) X Check filter condition X

1

Page 16: Exhibit II - MyFlorida.com Exhibit II Equipment Lists & Sample Service Sheet ... Trane : CCDB : AHU-S ; ... CSHC December 2, 2011 : 2 : I:

Sample Service Sheet

>­""C Q)

-+oJ

>­..c -+oJ c

>­ 0 ""C

~ L­

ro ro Sample -Type of Equipment Q) I ::J

>­ co (j

Operationals continued

Check with appropriate customer representative for operational deficiencies X Check belt(s) (if applicable) X Check coil conditions X Secure and check all electrical connectors X Inspect fan wheel for free movement, excessive play and debris X

Confirm that all mounting hardware is tight X Clean and Paint corroded areas as necessary X Check condensate pan and drain If accessible X

Filters, Misc.

Dispose of dirty filter appropriately X Turn equipment on X Install new filters X Remove dirty filters X Turn equipment off X Lubricate & inspect fan bearings. X Replace air filters per agreement X

Check with appropriate customer representative for operational deficiencies X IComplete any required maintenance checklists, report observations to

appropriate customer representative X

2