existing layout - cumberland council · stair stair stair stair stair admin admin dep general...
TRANSCRIPT
GSPublisherEngine 0.82.100.100
1 2 3 4 5 6 7 8
9
101112131415161718
TRAINING AREA (SAND PIT)
STAIR STAIR STAIR STAIR STAIR
ADMIN
ADMIN
DEPGENERALMANAGER
RECEPTION
HISTORICDISPLAY
AREA
OFFICE
OFFICE
OFFICE
SERVICE CPD
CPD
DISABLE WC
LIFT
MALEWC
FEMALEWC
FLAT
TEAROOM STORE / COMMS
STAIR
CANTEEN KITCHEN
DISWC
WC 2
WC 3
WC 4
WC 5
WAT
ERLE
SS U
RINA
LS
CORR
IDOR
SER
VICE
AIR LOCK
CANTEEN
OFFICE
RAMP 1
STAIR 1
WEL
DING
BAY
SW
ELDI
NG B
AYS
WELDING BAYS
WORKSHOP 2
WORKSHOP 1
CALSSFITTING ROOM
THEROSTATIC MIXINGVALVE ROOM BACKFLOW ROOM
CLASSROOM 1
COMMSROOM
ELEC
/ MEC
HSTAIRS 2
ENCLOSURE
WAREHOUSETEACHING
AREA 1
STOREROOM
ENVIROTRAINING ROOM
STAIRLOCKERROOMSTORAGE
STAIR
FOYER
TRAININGROOM
TRAININGROOM
MALEWC
FEMALEWC
DISABLEWC
COMPUTER / COMMS
WATER TANKS
DISTRIBUTIONBOARDS
PERCY STREET
GELIBOLU PARADE
A
Existing Ground Level
1 GROUND FLOOR1:200
EXISTING LAYOUTGENERAL NOTES
ALL DIMENSIONS AND SIZES ARE IN MILLIMETRES.DO NOT SCALE DRAWINGS.ALL WALL THICKNESSES DIMENSIONED OR NOTED ARENOMINAL SIZES ONLY.
READ THIS DRAWING IN CONJUNCTION WITH RELEVANT CONSULTANTDRAWINGS AND SPECIFICATIONS.INFORM THE ARCHITECT OF ANY DISCREPANCIES.6.
5.
4.
3.2.1.
INFORMATION INDICATED IN THIS DOCUMENT MAY BE CRUCIAL TOTHE SAFE AND PROPER FUNCTIONING OF THE PROJECT. DO NOTALTER ANY ASPECT WITHOUT REFERENCE TO THE ARCHITECT.
THE WORK IS TO BE COMPLETED WITH THE BUILDING CODEOF AUSTRALIA, SAA CODES AND RELEVANT BY-LAWS.THE BUILDING / MANUFACTURER SHALL CHECK ANDVERIFY ALL DIMENSIONS, RL GROUNDLINES ANDCONSTRUCTION METHODS PRIOR TO COMMENCEMENT OF WORK.PREFERNCES OF DIMENSIONED MESURMENT TO BETAKEN OVER SCALED MEASURMENTS.A COPY OF THIS PLAN IS TO BE SUBMITTED BY THEPROPRIETOR TO THE WATERBOARD FOR APPROVALAS REQUIRED BY THE LOCAL COUNCIL.
1:200
Drawing NoAddress
A-FE-111-001Revision2 PERCY STREET AUBURN NSW 2144
AUSTRALIA
Australian Turkish Maarif Foundation Limited
IS
Drawing TitleClient
Private Educational InstitutionProject
19/06/2017A1 Scale Date Checked
Project No
Pn_0648
10m1 2 3 4 50
ARCHITECTURE DESIGN STUDIO PTY LTDABN: 43 159 401 420
43/8 Avenue Of The AmericasNewington, NSW 2127
Phone: 02 9648 6663 l Fax: 02 9648 6664email: [email protected]
This drawing is protected by copyright. It may only be used forthe purpose for which it is issued
-
-
-
-
1:400A3 Scale
Rev Date Amendment By Rev Date Amendment By
GSPublisherEngine 0.82.100.100
1 2 3 4 5 6 7 8
9
101112131415161718
TRAINING AREA
TRAINING TRAINING TRAINING TRAINING TRAINING
TRAININGTRAININGTRAINING
STAIR STAIR OFFICE
STORAGE
FEMALEWC
MALEWC
NEW ARCHIVE & STORE
VOID
AIR LOCK
AIR LOCK
DISABLE WC
CHAIR STORE
OFFICE4
OFFICE3
OFFICE2
OFFICE1
OPEN PLAN OFFICE AREA
COPY & FILES
WAITING AREA / LOBBY
OFFICE5
TRAINING / LECTURE ROOM
STAIRS 2
RAMP 2
STAIR 6RAMP 3
OFFICE
OFFICE
OFFICE OFFICE OFFICE
BOARD-ROOM
REA PREP.
LIFT
KITCHEN
OFFICE
MALEWC
FEMALEWC
BALCONY
MALEWC
FEMALEWC
PERCY STREET
GELIBOLU PARADE
A
Existing FIRST FLOOR
1 FIRST FLOOR1:200
EXISTING LAYOUTGENERAL NOTES
ALL DIMENSIONS AND SIZES ARE IN MILLIMETRES.DO NOT SCALE DRAWINGS.ALL WALL THICKNESSES DIMENSIONED OR NOTED ARENOMINAL SIZES ONLY.
READ THIS DRAWING IN CONJUNCTION WITH RELEVANT CONSULTANTDRAWINGS AND SPECIFICATIONS.INFORM THE ARCHITECT OF ANY DISCREPANCIES.6.
5.
4.
3.2.1.
INFORMATION INDICATED IN THIS DOCUMENT MAY BE CRUCIAL TOTHE SAFE AND PROPER FUNCTIONING OF THE PROJECT. DO NOTALTER ANY ASPECT WITHOUT REFERENCE TO THE ARCHITECT.
THE WORK IS TO BE COMPLETED WITH THE BUILDING CODEOF AUSTRALIA, SAA CODES AND RELEVANT BY-LAWS.THE BUILDING / MANUFACTURER SHALL CHECK ANDVERIFY ALL DIMENSIONS, RL GROUNDLINES ANDCONSTRUCTION METHODS PRIOR TO COMMENCEMENT OF WORK.PREFERNCES OF DIMENSIONED MESURMENT TO BETAKEN OVER SCALED MEASURMENTS.A COPY OF THIS PLAN IS TO BE SUBMITTED BY THEPROPRIETOR TO THE WATERBOARD FOR APPROVALAS REQUIRED BY THE LOCAL COUNCIL.
1:200
Drawing NoAddress
A-FE-111-002Revision2 PERCY STREET AUBURN NSW 2144
AUSTRALIA
Australian Turkish Maarif Foundation Limited
IS
Drawing TitleClient
Private Educational InstitutionProject
19/06/2017A1 Scale Date Checked
Project No
Pn_0648
10m1 2 3 4 50
ARCHITECTURE DESIGN STUDIO PTY LTDABN: 43 159 401 420
43/8 Avenue Of The AmericasNewington, NSW 2127
Phone: 02 9648 6663 l Fax: 02 9648 6664email: [email protected]
This drawing is protected by copyright. It may only be used forthe purpose for which it is issued
-
-
-
-
1:400A3 Scale
Rev Date Amendment By Rev Date Amendment By
GSPublisherEngine 0.82.100.100
1 2 3 4 5 6 7 8
9
101112131415161718
TRAINING AREA (SAND PIT)
STAIR STAIR STAIR STAIR STAIR
ADMIN
ADMIN
DEPGENERALMANAGER
RECEPTION
HISTORICDISPLAY
AREA
OFFICE
OFFICE
OFFICE
SERVICE CPD
CPD
DISABLE WC
LIFT
MALEWC
FEMALEWC
FLAT
TEAROOM STORE / COMMS
STAIR
CANTEEN KITCHEN
DISWC
WC 2
WC 3
WC 4
WC 5
WAT
ERLE
SS U
RINA
LS
CORR
IDOR
SER
VICE
AIR LOCK
CANTEEN
OFFICE
RAMP 1
STAIR 1
WEL
DING
BAY
SW
ELDI
NG B
AYS
WELDING BAYS
WORKSHOP 2
WORKSHOP 1
CALSSFITTING ROOM
THEROSTATIC MIXINGVALVE ROOM BACKFLOW ROOM
CLASSROOM 1
COMMSROOM
ELEC
/ MEC
HSTAIRS 2
ENCLOSURE
WAREHOUSETEACHING
AREA 1
STOREROOM
ENVIROTRAINING ROOM
STAIRLOCKERROOMSTORAGE
STAIR
FOYER
TRAININGROOM
TRAININGROOM
MALEWC
FEMALEWC
DISABLEWC
COMPUTER / COMMS
WATER TANKS
DISTRIBUTIONBOARDS
PERCY STREET
GELIBOLU PARADE
PRIMARY GFAA: 2,956.74 m2
ADMIN GROUND GFAA: 421.42 m2
1 2 3 4 5 6 7 8
9
101112131415161718
TRAINING AREA
TRAINING TRAINING TRAINING TRAINING TRAINING
TRAININGTRAININGTRAINING
STAIR STAIR OFFICE
STORAGE
FEMALEWC
MALEWC
NEW ARCHIVE & STORE
VOID
AIR LOCK
AIR LOCK
DISABLE WC
CHAIR STORE
OFFICE4
OFFICE3
OFFICE2
OFFICE1
OPEN PLAN OFFICE AREA
COPY & FILES
WAITING AREA / LOBBY
OFFICE5
TRAINING / LECTURE ROOM
STAIRS 2
RAMP 2
STAIR 6RAMP 3
OFFICE
OFFICE
OFFICE OFFICE OFFICE
BOARD-ROOM
REA PREP.
LIFT
KITCHEN
OFFICE
MALEWC
FEMALEWC
BALCONY
MALEWC
FEMALEWC
PERCY STREET
GELIBOLU PARADE
SECONDARY GFAA: 591.74 m2
ADMIN FIRST GFAA: 295.27 m2
SECONDARY GFAA: 696.63 m2
A
Existing GFA
1 GROUND FLOOR - GFA1:200
1 FIRST FLOOR - GFA1:200
EXISTING LAYOUT
SITE AREA 7142.7TOTAL GFA 4961.8FSR 0.69:1
GENERAL NOTESALL DIMENSIONS AND SIZES ARE IN MILLIMETRES.DO NOT SCALE DRAWINGS.ALL WALL THICKNESSES DIMENSIONED OR NOTED ARENOMINAL SIZES ONLY.
READ THIS DRAWING IN CONJUNCTION WITH RELEVANT CONSULTANTDRAWINGS AND SPECIFICATIONS.INFORM THE ARCHITECT OF ANY DISCREPANCIES.6.
5.
4.
3.2.1.
INFORMATION INDICATED IN THIS DOCUMENT MAY BE CRUCIAL TOTHE SAFE AND PROPER FUNCTIONING OF THE PROJECT. DO NOTALTER ANY ASPECT WITHOUT REFERENCE TO THE ARCHITECT.
THE WORK IS TO BE COMPLETED WITH THE BUILDING CODEOF AUSTRALIA, SAA CODES AND RELEVANT BY-LAWS.THE BUILDING / MANUFACTURER SHALL CHECK ANDVERIFY ALL DIMENSIONS, RL GROUNDLINES ANDCONSTRUCTION METHODS PRIOR TO COMMENCEMENT OF WORK.PREFERNCES OF DIMENSIONED MESURMENT TO BETAKEN OVER SCALED MEASURMENTS.A COPY OF THIS PLAN IS TO BE SUBMITTED BY THEPROPRIETOR TO THE WATERBOARD FOR APPROVALAS REQUIRED BY THE LOCAL COUNCIL.
1:200
Drawing NoAddress
A-FE-111-003Revision2 PERCY STREET AUBURN NSW 2144
AUSTRALIA
Australian Turkish Maarif Foundation Limited
IS
Drawing TitleClient
Private Educational InstitutionProject
19/06/2017A1 Scale Date Checked
Project No
Pn_0648
10m1 2 3 4 50
ARCHITECTURE DESIGN STUDIO PTY LTDABN: 43 159 401 420
43/8 Avenue Of The AmericasNewington, NSW 2127
Phone: 02 9648 6663 l Fax: 02 9648 6664email: [email protected]
This drawing is protected by copyright. It may only be used forthe purpose for which it is issued
-
-
-
-
1:400A3 Scale
Rev Date Amendment By Rev Date Amendment By
GSPublisherEngine 0.82.100.100
12
3
43 44 45 46 47 48 49 50 51 52 45
67
89
1011
12
141516171819202122232425
26
27
28
29
30
31
32
33 34 35 36 37 38 39 40 41 42
13
000000
1 2 3 4 5 6 7 8
9
101112131415161718
1 2 3 4 5 6 7 8
9
101112131415161718
15 x 187 = 2,800
12345
678910
11
12 13 14 15
STAIR
Outdoor open space 1,178.94 m2
RECEPTION
STORAGE
MULTI PURPOSE H
COMPUTER LABSTAFF ROOMBATHROOM
ART ROOM
STAGE
CANTINE
LIBRARY
MULTI / STORAGE
SICK BAY
INTER. ROOM
INTER. ROOM
CLASSROOM 8
CLASSROOM 14
SUPPORT ROOM
FIRE STAIRS
ASSEMBLY AREA CLASSROOM 13CLASSROOM 12CLASSROOM 11CLASSROOM 10CLASSROOM 9
CLASSROOM 1CLASSROOM 2CLASSROOM 3CLASSROOM 4CLASSROOM 5CLASSROOM 6CLASSROOM 7
LOCKERS
FIRE STAIRS
ASSEMBLY AREA
UNIFORM SHOP
ACCOUNT / ADMIN
RECEPTION
DISPLAYAREA
SERVICE CPD
CPD
DISABLE WC
LIFT
MALEWC
FEMALEWC
FLAT
TEAROOM STORE / PRINTER
STAIR
PERCY STREET
GELIBOLU PARADE PRIMARY SECONDARYASSEMBLY
AREA
DEPUTYPRINCIPLE
CORDINATOR
SEATING AREA
CAR PARK52 SPACES
INDOOR PLAY AREA
499.76 m2
95.97 m2
78.20 m2
52.00 m2
24.14 m2
110.46 m2
15.05 m2
68.70 m2
67.00 m2
71.46 m2
78.20 m2
42.87 m2 112.41 m2
57.20 m2 67.00 m267.00 m267.00 m267.00 m267.00 m2
67.00 m267.00 m267.00 m267.00 m267.00 m267.00 m267.00 m2
21.45 m2
MAIN LOBBY
A
Proposed Ground Level
1 GROUND FLOOR1:200
PROPOSED LAYOUTGENERAL NOTES
ALL DIMENSIONS AND SIZES ARE IN MILLIMETRES.DO NOT SCALE DRAWINGS.ALL WALL THICKNESSES DIMENSIONED OR NOTED ARENOMINAL SIZES ONLY.
READ THIS DRAWING IN CONJUNCTION WITH RELEVANT CONSULTANTDRAWINGS AND SPECIFICATIONS.INFORM THE ARCHITECT OF ANY DISCREPANCIES.6.
5.
4.
3.2.1.
INFORMATION INDICATED IN THIS DOCUMENT MAY BE CRUCIAL TOTHE SAFE AND PROPER FUNCTIONING OF THE PROJECT. DO NOTALTER ANY ASPECT WITHOUT REFERENCE TO THE ARCHITECT.
THE WORK IS TO BE COMPLETED WITH THE BUILDING CODEOF AUSTRALIA, SAA CODES AND RELEVANT BY-LAWS.THE BUILDING / MANUFACTURER SHALL CHECK ANDVERIFY ALL DIMENSIONS, RL GROUNDLINES ANDCONSTRUCTION METHODS PRIOR TO COMMENCEMENT OF WORK.PREFERNCES OF DIMENSIONED MESURMENT TO BETAKEN OVER SCALED MEASURMENTS.A COPY OF THIS PLAN IS TO BE SUBMITTED BY THEPROPRIETOR TO THE WATERBOARD FOR APPROVALAS REQUIRED BY THE LOCAL COUNCIL.
1:200
Drawing NoAddress
A-FE-111-004Revision2 PERCY STREET AUBURN NSW 2144
AUSTRALIA
Australian Turkish Maarif Foundation Limited
IS
Drawing TitleClient
Private Educational InstitutionProject
19/06/2017A1 Scale Date Checked
Project No
Pn_0648
10m1 2 3 4 50
ARCHITECTURE DESIGN STUDIO PTY LTDABN: 43 159 401 420
43/8 Avenue Of The AmericasNewington, NSW 2127
Phone: 02 9648 6663 l Fax: 02 9648 6664email: [email protected]
This drawing is protected by copyright. It may only be used forthe purpose for which it is issued
-
-
-
-
1:400A3 Scale
Rev Date Amendment By Rev Date Amendment By
GSPublisherEngine 0.82.100.100
1 2 3 4 5 6 7 8
9
101112131415161718
1 2 3 4 5 6 7 8
9
101112131415161718
15 x 187 = 2,800
12345
678910
11
12 13 14 15
15 x 187 = 2,800
12345
678910
11
12 13 14 15
STO
RA
GE
COUNSELLOR OFF.
BOARD-ROOM
IT ROOM
PRESIDENT
PRINCIPLE
CLASSROOM 8
FIRE STAIRS
FIRE STAIRS
CLASSROOM 9
CLASSROOM 1CLASSROOM 2CLASSROOM 3CLASSROOM 4CLASSROOM 5CLASSROOM 6CLASSROOM 7
BIOLOGY
CLASSROOM 10 CLASSROOM 11 CLASSROOM 12
STAFF ROOMSTAFF ROOM
LOCKERS
GENERAL SCIENCE
CORDINATOR
LECTURE ROOM
STORAGE
STORAGE
PREP AREA
STORAGE
PREP AREA
ASSEMBLY AREA
BATHROOMSTAFF ROOM LIBRARYCOMPUTER LAB
STAFF ROOM
FOOD TECHNOLOGY
RAMP 3
REA PREP.
LIFT
KITCHEN
MALEWC
FEMALEWC
LOUNGE
PERCY STREET
GELIBOLU PARADE
CPD
SECONDARYASSEMBLY
AREA
CHEMISTRY /PHYSICS LAB
68.70 m2 67.00 m267.00 m267.00 m267.00 m267.00 m267.00 m267.00 m2
49.58 m2 49.58 m2 49.58 m2 49.58 m2
18.34 m218.34 m2
280.90 m2
30.08 m2
110.00 m2
6.62 m2
6.62 m2
19.26 m2
26.36 m2
129.10 m213.64 m2
57.33 m2
95.97 m2
71.46 m2 266.34 m242.02 m2
14.84 m2
102.66 m2
A
Proposed FIRST FLOOR
1 FIRST FLOOR1:200
PROPOSED LAYOUTGENERAL NOTES
ALL DIMENSIONS AND SIZES ARE IN MILLIMETRES.DO NOT SCALE DRAWINGS.ALL WALL THICKNESSES DIMENSIONED OR NOTED ARENOMINAL SIZES ONLY.
READ THIS DRAWING IN CONJUNCTION WITH RELEVANT CONSULTANTDRAWINGS AND SPECIFICATIONS.INFORM THE ARCHITECT OF ANY DISCREPANCIES.6.
5.
4.
3.2.1.
INFORMATION INDICATED IN THIS DOCUMENT MAY BE CRUCIAL TOTHE SAFE AND PROPER FUNCTIONING OF THE PROJECT. DO NOTALTER ANY ASPECT WITHOUT REFERENCE TO THE ARCHITECT.
THE WORK IS TO BE COMPLETED WITH THE BUILDING CODEOF AUSTRALIA, SAA CODES AND RELEVANT BY-LAWS.THE BUILDING / MANUFACTURER SHALL CHECK ANDVERIFY ALL DIMENSIONS, RL GROUNDLINES ANDCONSTRUCTION METHODS PRIOR TO COMMENCEMENT OF WORK.PREFERNCES OF DIMENSIONED MESURMENT TO BETAKEN OVER SCALED MEASURMENTS.A COPY OF THIS PLAN IS TO BE SUBMITTED BY THEPROPRIETOR TO THE WATERBOARD FOR APPROVALAS REQUIRED BY THE LOCAL COUNCIL.
1:200
Drawing NoAddress
A-FE-111-005Revision2 PERCY STREET AUBURN NSW 2144
AUSTRALIA
Australian Turkish Maarif Foundation Limited
IS
Drawing TitleClient
Private Educational InstitutionProject
19/06/2017A1 Scale Date Checked
Project No
Pn_0648
10m1 2 3 4 50
ARCHITECTURE DESIGN STUDIO PTY LTDABN: 43 159 401 420
43/8 Avenue Of The AmericasNewington, NSW 2127
Phone: 02 9648 6663 l Fax: 02 9648 6664email: [email protected]
This drawing is protected by copyright. It may only be used forthe purpose for which it is issued
-
-
-
-
1:400A3 Scale
Rev Date Amendment By Rev Date Amendment By
GSPublisherEngine 0.82.100.100
15 x 187 = 2,800
12345
678910
11
12 13 14 15
2,694.80 m2
LIFT
PERCY STREET
GELIBOLU PARADE
ROOF TOP OPEN SPACE
BATHROOM
95.97 m2168.37 m2
CAFETARIA
A
Proposed SECOND FLOOR
1 SECOND FLOOR1:200
PROPOSED LAYOUTGENERAL NOTES
ALL DIMENSIONS AND SIZES ARE IN MILLIMETRES.DO NOT SCALE DRAWINGS.ALL WALL THICKNESSES DIMENSIONED OR NOTED ARENOMINAL SIZES ONLY.
READ THIS DRAWING IN CONJUNCTION WITH RELEVANT CONSULTANTDRAWINGS AND SPECIFICATIONS.INFORM THE ARCHITECT OF ANY DISCREPANCIES.6.
5.
4.
3.2.1.
INFORMATION INDICATED IN THIS DOCUMENT MAY BE CRUCIAL TOTHE SAFE AND PROPER FUNCTIONING OF THE PROJECT. DO NOTALTER ANY ASPECT WITHOUT REFERENCE TO THE ARCHITECT.
THE WORK IS TO BE COMPLETED WITH THE BUILDING CODEOF AUSTRALIA, SAA CODES AND RELEVANT BY-LAWS.THE BUILDING / MANUFACTURER SHALL CHECK ANDVERIFY ALL DIMENSIONS, RL GROUNDLINES ANDCONSTRUCTION METHODS PRIOR TO COMMENCEMENT OF WORK.PREFERNCES OF DIMENSIONED MESURMENT TO BETAKEN OVER SCALED MEASURMENTS.A COPY OF THIS PLAN IS TO BE SUBMITTED BY THEPROPRIETOR TO THE WATERBOARD FOR APPROVALAS REQUIRED BY THE LOCAL COUNCIL.
1:200
Drawing NoAddress
A-FE-111-006Revision2 PERCY STREET AUBURN NSW 2144
AUSTRALIA
Australian Turkish Maarif Foundation Limited
IS
Drawing TitleClient
Private Educational InstitutionProject
19/06/2017A1 Scale Date Checked
Project No
Pn_0648
10m1 2 3 4 50
ARCHITECTURE DESIGN STUDIO PTY LTDABN: 43 159 401 420
43/8 Avenue Of The AmericasNewington, NSW 2127
Phone: 02 9648 6663 l Fax: 02 9648 6664email: [email protected]
This drawing is protected by copyright. It may only be used forthe purpose for which it is issued
-
-
-
-
1:400A3 Scale
Rev Date Amendment By Rev Date Amendment By
GSPublisherEngine 0.82.100.100
1 2 3 4 5 6 7 8
9
101112131415161718
1 2 3 4 5 6 7 8
9
101112131415161718
15 x 187 = 2,800
12345
678910
11
12 13 14 15
STAIR
Outdoor open space 1,178.94 m2
RECEPTION
STORAGE
MULTI PURPOSE H
COMPUTER LABSTAFF ROOMBATHROOM
ART ROOM
STAGE
CANTINE
LIBRARY
MULTI / STORAGE
SICK BAY
INTER. ROOM
INTER. ROOM
CLASSROOM 8
CLASSROOM 14
SUPPORT ROOM
FIRE STAIRS
ASSEMBLY AREA CLASSROOM 13CLASSROOM 12CLASSROOM 11CLASSROOM 10CLASSROOM 9
CLASSROOM 1CLASSROOM 2CLASSROOM 3CLASSROOM 4CLASSROOM 5CLASSROOM 6CLASSROOM 7
LOCKERS
FIRE STAIRS
ASSEMBLY AREA
UNIFORM SHOP
ACCOUNT / ADMIN
RECEPTION
DISPLAYAREA
SERVICE CPD
CPD
DISABLE WC
LIFT
MALEWC
FEMALEWC
FLAT
TEAROOM STORE / PRINTER
STAIR
PERCY STREET
GELIBOLU PARADE PRIMARY SECONDARYASSEMBLY
AREA
DEPUTYPRINCIPLE
CORDINATOR
SEATING AREAINDOOR PLAY AREA
499.76 m2
95.97 m2
78.20 m2
52.00 m2
24.14 m2
110.46 m2
15.05 m2
68.70 m2
67.00 m2
71.46 m2
78.20 m2
42.87 m2 112.41 m2
57.20 m2 67.00 m267.00 m267.00 m267.00 m267.00 m2
67.00 m267.00 m267.00 m267.00 m267.00 m267.00 m267.00 m2
21.45 m2
MAIN LOBBY
PRIMARY GFAA: 2,999.26 m2
ADMIN GROUND GFAA: 421.42 m2
1 2 3 4 5 6 7 8
9
101112131415161718
1 2 3 4 5 6 7 8
9
101112131415161718
15 x 187 = 2,800
12345
678910
11
12 13 14 15
15 x 187 = 2,800
12345
678910
11
12 13 14 15
STO
RA
GE
COUNSELLOR OFF.
BOARD-ROOM
IT ROOM
PRESIDENT
PRINCIPLE
CLASSROOM 8
FIRE STAIRS
FIRE STAIRS
CLASSROOM 9
CLASSROOM 1CLASSROOM 2CLASSROOM 3CLASSROOM 4CLASSROOM 5CLASSROOM 6CLASSROOM 7
BIOLOGY
CLASSROOM 10 CLASSROOM 11 CLASSROOM 12
STAFF ROOMSTAFF ROOM
LOCKERS
GENERAL SCIENCE
CORDINATOR
LECTURE ROOM
STORAGE
STORAGE
PREP AREA
STORAGE
PREP AREA
ASSEMBLY AREA
BATHROOMSTAFF ROOM LIBRARYCOMPUTER LAB
STAFF ROOM
FOOD TECHNOLOGY
RAMP 3
REA PREP.
LIFT
KITCHEN
MALEWC
FEMALEWC
LOUNGE
PERCY STREET
GELIBOLU PARADE
CPD
SECONDARYASSEMBLY
AREA
CHEMISTRY /PHYSICS LAB
68.70 m2 67.00 m267.00 m267.00 m267.00 m267.00 m267.00 m267.00 m2
49.58 m2 49.58 m2 49.58 m2 49.58 m2
18.34 m218.34 m2
280.90 m2
30.08 m2
110.00 m2
6.62 m2
6.62 m2
19.26 m2
26.36 m2
129.10 m213.64 m2
57.33 m2
95.97 m2
71.46 m2 266.34 m242.02 m2
14.84 m2
102.66 m2
FIRST FLOOR GFAA: 2,999.26 m2
ADMIN FIRST GFAA: 418.29 m2
15 x 187 = 2,800
12345
678910
11
12 13 14 15
2,694.80 m2
LIFT
PERCY STREET
GELIBOLU PARADE
ROOF TOP OPEN SPACE
BATHROOM
95.97 m2168.37 m2
CAFETARIA
SECOND FLOOR GFAA: 304.47 m2
A
Proposed GFA
1 GROUND FLOOR - GFA1:300
1 FIRST FLOOR - GFA1:300
1 SECOND FLOOR - GFA1:300
PROPOSED LAYOUT
SITE AREA 7142.7TOTAL GFA 7142.7FSR 1:1
GENERAL NOTESALL DIMENSIONS AND SIZES ARE IN MILLIMETRES.DO NOT SCALE DRAWINGS.ALL WALL THICKNESSES DIMENSIONED OR NOTED ARENOMINAL SIZES ONLY.
READ THIS DRAWING IN CONJUNCTION WITH RELEVANT CONSULTANTDRAWINGS AND SPECIFICATIONS.INFORM THE ARCHITECT OF ANY DISCREPANCIES.6.
5.
4.
3.2.1.
INFORMATION INDICATED IN THIS DOCUMENT MAY BE CRUCIAL TOTHE SAFE AND PROPER FUNCTIONING OF THE PROJECT. DO NOTALTER ANY ASPECT WITHOUT REFERENCE TO THE ARCHITECT.
THE WORK IS TO BE COMPLETED WITH THE BUILDING CODEOF AUSTRALIA, SAA CODES AND RELEVANT BY-LAWS.THE BUILDING / MANUFACTURER SHALL CHECK ANDVERIFY ALL DIMENSIONS, RL GROUNDLINES ANDCONSTRUCTION METHODS PRIOR TO COMMENCEMENT OF WORK.PREFERNCES OF DIMENSIONED MESURMENT TO BETAKEN OVER SCALED MEASURMENTS.A COPY OF THIS PLAN IS TO BE SUBMITTED BY THEPROPRIETOR TO THE WATERBOARD FOR APPROVALAS REQUIRED BY THE LOCAL COUNCIL.
1:200
Drawing NoAddress
A-FE-111-007Revision2 PERCY STREET AUBURN NSW 2144
AUSTRALIA
Australian Turkish Maarif Foundation Limited
IS
Drawing TitleClient
Private Educational InstitutionProject
19/06/2017A1 Scale Date Checked
Project No
Pn_0648
10m1 2 3 4 50
ARCHITECTURE DESIGN STUDIO PTY LTDABN: 43 159 401 420
43/8 Avenue Of The AmericasNewington, NSW 2127
Phone: 02 9648 6663 l Fax: 02 9648 6664email: [email protected]
This drawing is protected by copyright. It may only be used forthe purpose for which it is issued
-
-
-
-
1:400A3 Scale
Rev Date Amendment By Rev Date Amendment By
GSPublisherEngine 0.82.100.100
78
910
1112
141516171819202122232425
26
27
28
29
30
31
32
33 34 35 36 37 38 39 40 41 42
13
000000
1 2 3 4 5 6 7 8
9
101112131415161718
1 2 3 4 5 6 7 8
9
101112131415161718
15 x 187 = 2,800
12345
678910
11
12 13 14 15
STAIR
Outdoor open space 1,178.94 m2
RECEPTION
STORAGE
MULTI PURPOSE H
COMPUTER LABSTAFF ROOMBATHROOM
ART ROOM
STAGE
CANTINE
LIBRARY
MULTI / STORAGE
SICK BAY
INTER. ROOM
INTER. ROOM
CLASSROOM 8
CLASSROOM 14
SUPPORT ROOM
FIRE STAIRS
ASSEMBLY AREA CLASSROOM 13CLASSROOM 12CLASSROOM 11CLASSROOM 10CLASSROOM 9
CLASSROOM 1CLASSROOM 2CLASSROOM 3CLASSROOM 4CLASSROOM 5CLASSROOM 6CLASSROOM 7
LOCKERS
FIRE STAIRS
ASSEMBLY AREA
UNIFORM SHOP
ACCOUNT / ADMIN
RECEPTION
DISPLAYAREA
SERVICE CPD
CPD
DISABLE WC
LIFT
MALEWC
FEMALEWC
FLAT
TEAROOM STORE / PRINTER
STAIR
PERCY STREET
GELIBOLU PARADE PRIMARY SECONDARYASSEMBLY
AREA
DEPUTYPRINCIPLE
CORDINATOR
SEATING AREA
CAR PARK52 SPACES
INDOOR PLAY AREA
499.76 m2
95.97 m2
78.20 m2
52.00 m2
24.14 m2
110.46 m2
15.05 m2
68.70 m2
67.00 m2
71.46 m2
78.20 m2
42.87 m2 112.41 m2
57.20 m2 67.00 m267.00 m267.00 m267.00 m267.00 m2
67.00 m267.00 m267.00 m267.00 m267.00 m267.00 m267.00 m2
21.45 m2
MAIN LOBBY
15 x 187 = 2,800
12345
678910
11
12 13 14 15
2,694.80 m2
LIFT
PERCY STREET
GELIBOLU PARADE
ROOF TOP OPEN SPACE
BATHROOM
95.97 m2168.37 m2
CAFETARIA
A
Proposed Outdoor Area
1 GROUND FLOOR1:300
1 SECOND FLOOR1:300
PROPOSED LAYOUT
SITE AREA 7142.7TOTAL OUTDOOR
AREA 3873.74
GENERAL NOTESALL DIMENSIONS AND SIZES ARE IN MILLIMETRES.DO NOT SCALE DRAWINGS.ALL WALL THICKNESSES DIMENSIONED OR NOTED ARENOMINAL SIZES ONLY.
READ THIS DRAWING IN CONJUNCTION WITH RELEVANT CONSULTANTDRAWINGS AND SPECIFICATIONS.INFORM THE ARCHITECT OF ANY DISCREPANCIES.6.
5.
4.
3.2.1.
INFORMATION INDICATED IN THIS DOCUMENT MAY BE CRUCIAL TOTHE SAFE AND PROPER FUNCTIONING OF THE PROJECT. DO NOTALTER ANY ASPECT WITHOUT REFERENCE TO THE ARCHITECT.
THE WORK IS TO BE COMPLETED WITH THE BUILDING CODEOF AUSTRALIA, SAA CODES AND RELEVANT BY-LAWS.THE BUILDING / MANUFACTURER SHALL CHECK ANDVERIFY ALL DIMENSIONS, RL GROUNDLINES ANDCONSTRUCTION METHODS PRIOR TO COMMENCEMENT OF WORK.PREFERNCES OF DIMENSIONED MESURMENT TO BETAKEN OVER SCALED MEASURMENTS.A COPY OF THIS PLAN IS TO BE SUBMITTED BY THEPROPRIETOR TO THE WATERBOARD FOR APPROVALAS REQUIRED BY THE LOCAL COUNCIL.
1:200
Drawing NoAddress
A-FE-111-008Revision2 PERCY STREET AUBURN NSW 2144
AUSTRALIA
Australian Turkish Maarif Foundation Limited
IS
Drawing TitleClient
Private Educational InstitutionProject
19/06/2017A1 Scale Date Checked
Project No
Pn_0648
10m1 2 3 4 50
ARCHITECTURE DESIGN STUDIO PTY LTDABN: 43 159 401 420
43/8 Avenue Of The AmericasNewington, NSW 2127
Phone: 02 9648 6663 l Fax: 02 9648 6664email: [email protected]
This drawing is protected by copyright. It may only be used forthe purpose for which it is issued
-
-
-
-
1:400A3 Scale
Rev Date Amendment By Rev Date Amendment By