June 12, 2012 1 Experiences using Guided Wave ultrasonic testing 12.6.2012 NDT Conference, Bergen Sami Hemminki, BSc

Upload: others

Post on 16-Apr-2020

12 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Experiences using Guided Wave ultrasonic testingndt.sitegen.no/customers/ndt/files/Experiences, guided... · 2012-06-12 · Experiences using Guided Wave ultrasonic testing 12.6.2012

June 12, 2012 1

Experiences using Guided Wave ultrasonic testing

12.6.2012 NDT Conference, Bergen

Sami Hemminki, BSc

Page 2: Experiences using Guided Wave ultrasonic testingndt.sitegen.no/customers/ndt/files/Experiences, guided... · 2012-06-12 · Experiences using Guided Wave ultrasonic testing 12.6.2012

June 12, 2012 2

• 2009 First Wavemaker G3 was bought to Inspecta Finland

- Level I certificates 09/2009 ( Mr. Hemminki, Mr. Anglé and Mr. Palkeinen )

- Demo events in the end of 2009.

• 2010 basic above ground guided wave jobs + demo events, mainly:

- Oil refineries

- Tank farms

- Harbours

- 2010 supplemental road crossings –course.

• 2011 First Wavemaker G3 was bought to Inspecta Sweden

- Level I certificates ( Mr. Bornhöft, Mr. Candan and Mr. Karlsson )

• 2011 Level II certificate ( Mr. Hemminki)

- Inspection procedure: Inspection of pipelines using guided waves ( Mr.Hemminki)

- From the beginning to this day

Experiences using Guided Wave ultrasonic testing

Sami Hemminki, BSc

Page 3: Experiences using Guided Wave ultrasonic testingndt.sitegen.no/customers/ndt/files/Experiences, guided... · 2012-06-12 · Experiences using Guided Wave ultrasonic testing 12.6.2012

GUIDED WAVE Method

Case Study 1

20”-line

In this case the inspection was performed

on a 20 inch pipeline with inflatable

transducer ring.

Pipeline was insulated and general surface

condition of the pipe was good.

The result of the guided wave wavemaker is

shown on the top picture.

Indication from distance ~11m did not match

with any obvious mechanical connection,so

it was decided to take off insulating material

to verify the cause of indication.

Severe corrosion was found under insulating

material.

June 12, 2012 Sami Hemminki, BSc 3

Page 4: Experiences using Guided Wave ultrasonic testingndt.sitegen.no/customers/ndt/files/Experiences, guided... · 2012-06-12 · Experiences using Guided Wave ultrasonic testing 12.6.2012

GUIDED WAVE Method

Case Study 2

20”-line

In this case the inspection was

performed on a 20 inch pipeline with

inflatable transducer ring.

Pipeline was insulated and general

surface condition of the pipe was good.

The result of the guided wave

wavemaker is shown on the top picture.

Several indications were found from

support area.

Confirmed visually as a severe

corrosion nearby the support.

June 12, 2012 Sami Hemminki, BSc 4

Page 5: Experiences using Guided Wave ultrasonic testingndt.sitegen.no/customers/ndt/files/Experiences, guided... · 2012-06-12 · Experiences using Guided Wave ultrasonic testing 12.6.2012

June 12, 2012 5

10”-line

In this case the inspection was performed

on a 10 inch pipeline with inflatable

transducer ring. Pipeline was insulated

and general surface condition of the pipe

was good.

Inspected total lenght was ~ 260 meters.

The result of the guided wave

wavemaker is shown on the top picture.

Indication from distance 2m to 4m

(neg.direction)

Severe corrosion was found under

Insulating material.

Maximum wall loss 50-60 %,

from nominal 6,3 to minimum 2,6 mm

GUIDED WAVE Method

Case Study 3

Sami Hemminki, BSc

Page 6: Experiences using Guided Wave ultrasonic testingndt.sitegen.no/customers/ndt/files/Experiences, guided... · 2012-06-12 · Experiences using Guided Wave ultrasonic testing 12.6.2012

GUIDED WAVE Method

Case Study 4

8”-line, ”No relevant indications /

severe indications”

In this case the inspection was performed

on a 8 inch pipeline with inflatable

transducer-ring.

Pipeline was non-insulated and general

surface condition of the pipe was good.

The result of a ”clear” guided wave

wavemaker data is shown on the top picture.

The lower picture represents corroded area

from the same pipeline as above.

June 12, 2012 Sami Hemminki, BSc 6

Page 7: Experiences using Guided Wave ultrasonic testingndt.sitegen.no/customers/ndt/files/Experiences, guided... · 2012-06-12 · Experiences using Guided Wave ultrasonic testing 12.6.2012

June 12, 2012 7

• Reformer tubes in hydrogen furnace

• Centrifugal casting, austenitic

• Size: 155x14 mm (6” inflatable ring)

• Looking for (cracks.)

- any changes in cross-section

• Testing was performed

before and after removal of catalyst

GUIDED WAVE Method

Case Study Reformer tubes

Page 8: Experiences using Guided Wave ultrasonic testingndt.sitegen.no/customers/ndt/files/Experiences, guided... · 2012-06-12 · Experiences using Guided Wave ultrasonic testing 12.6.2012

June 12, 2012 8

Page 9: Experiences using Guided Wave ultrasonic testingndt.sitegen.no/customers/ndt/files/Experiences, guided... · 2012-06-12 · Experiences using Guided Wave ultrasonic testing 12.6.2012

June 12, 2012 9

GUIDED WAVE Method

Case Study Reformer tubes

N 1

2 3

4 5

6 7

51

1

Row 3 tubes 17- 31

Row 4 tubes 31- 32

Row 5 tubes 31- 32

Row 6 tubes 21- 30

Row 7 tubes 17- 31

Total: 44 tubes.

REFORMER UNIT

Page 10: Experiences using Guided Wave ultrasonic testingndt.sitegen.no/customers/ndt/files/Experiences, guided... · 2012-06-12 · Experiences using Guided Wave ultrasonic testing 12.6.2012

June 12, 2012 10

-18dB

0.0 5.0 10.012

9

6

3

12

Clo

ck

0.0 5.0 10.00.0

0.2

0.4

0.6

0.8

1.0

1.2

Distance (m)

Am

p (

Lin

ear)

+F1

+F2

+F3

+F4

+F5

-F1

Before removal of catalyst

Page 11: Experiences using Guided Wave ultrasonic testingndt.sitegen.no/customers/ndt/files/Experiences, guided... · 2012-06-12 · Experiences using Guided Wave ultrasonic testing 12.6.2012

June 12, 2012 11

-18dB

-2.0 0.0 2.0 4.0 6.0 8.0 10.012

9

6

3

12

Clo

ck

-2.0 0.0 2.0 4.0 6.0 8.0 10.00.0

0.5

1.0

1.5

Distance (m)

Am

p (

Lin

ear)

-F1

+F1

+F2

+F3

+F4

+F5

After removal of catalyst

Page 12: Experiences using Guided Wave ultrasonic testingndt.sitegen.no/customers/ndt/files/Experiences, guided... · 2012-06-12 · Experiences using Guided Wave ultrasonic testing 12.6.2012

June 12, 2012 12 Sami Hemminki, BSc