explore multi-modality images in multiple ways
TRANSCRIPT
Key advantages
• Save time and space: Current and prior studies are available at a single workspace
• Quality of care: Display past medical history and report data using BI-RADS® standard
• Enhancedworkflow:UtilizetheavailableAPIto interface with your existing reporting or information system
Explore multi-modality images in multiple ways PhilipsIntelliSpaceBreastspecifi cation*
Philips IntelliSpace Breast with the IntelliSpace Clinical Applications, help you keep pace with the demands of your radiology department – by giving you the freedom to open, review, and diagnose patients’ mammography, ultrasound, and MRI images from a single workspace.
*Specificationsaresubjecttochangeatanytimewithoutnotice.
452296297571.indd 1 3-10-2013 9:18:28
3
Content
Software04 IntelliSpace Breast – Mammography06 IntelliSpaceBreast*–BreastUltrasoundReviewoption07 IntelliSpace Breast* – Breast MRI Review option
Hardware09 Server Client Mammography keypad10 Navigation monitor Color application monitor11 5MPMonitorsMammography:BarcoNio12 5MPMonitorsMammography:BarcoCoronis
10MPMonitorsMammography:BarcoCoronisFusion
13 Additional options Media Writer/CD-DVD Robot DICOM pre-fetching module
* Multi-modality options powered by IntelliSpace Clinical Applications
452296297571.indd 3 3-10-2013 9:18:31
4
InteroperabilityMulti-vendor compatible YesCohabitation of reporting and speech software (utilizesamehardwarewithnoexchangeofinformation)
Yes
Availableopeninterface(API)thatenables RIS and/or MIS interface capabilities
Yes
DICOM Services StoreQuery/retrievePrintmanagement(onlywith8bit)
Import of images from CD/DVD Yes,withPacsScanExportofimagestoCD/DVD/USBflashdrive YesDICOM viewer for exported images RequiresPAGSGEARMediaWriterCD/DVDrobotDICOM DIR RequiresPAGSGEARMediaWriterCD/DVDrobotMake patient data anonymous YesPrinttopaper Yes
IntelliSpace Breast – Mammography
WorkflowPasswordforindividualreaders YesConfigurableworklistsperuser YesAvailable default worklists • Patientlookup:Generalsearchforpatientsinsystem
database• Notreadbyme:Showsallexaminationsinaspecified
timeframe which have not been read• My History: Chronological overview of viewed
patientsPatient-focusedapproach:automaticdisplayofallavailableprior data for comparison next to the current exam
Yes
Automatic selection of next patient in worklist YesGraphical,patienthistorytimeline:overviewoftherelevant patient history
Yes
452296297571.indd 4 3-10-2013 9:18:31
5
IntelliSpace Breast Mammography
Hanging protocols • Predefineduserhangingprotocols• Customizationofhangingprotocolaccordingtouser
preferences• Automatic detection of priors• Automatichangingofpriors(DR,CR,anddigitizedfilm)• Switchingbetweenpriorswithjustoneclick
Viewing tools • Window width/Window level• Inversion with background air suppression• Edge enhancement• CLAHE(contrastlimitedadaptivehistogramequalization)• Pan• Zoom• Fit-to-window• Truesize(lifesize)• Stepzoomwithpixeltopixelresolution• Magnifying glass• Rotationandflippingofimages• RegionofInterest(circle,ellipse,freehand,pointvalue)• Several choices of monitor layouts• Saveimage/windowtoclipboardorfile(.jpeg,.bmp,.gif,.tif,.png)
Measurements • Height• Width• Depth• Distance from skin• Distance from nipple• Distance from chest wall
Show/hide measurement YesAutomatic breast tissue alignment for improved left and right comparison
Yes
Automaticbreastfit-to-windowforfastreview YesAutomatic scaling of current and prior images YesMirroredlinkingofimagesforzoomingandpanning YesDisplay of CAD marker YesAbility to view a second case without closing current case in review
Yes
Tomo Viewing Yes
452296297571.indd 5 3-10-2013 9:18:31
6
IntelliSpace Breast* – Breast Ultrasound Review option
WorkflowSchematicbreastdiagramtovisuallyreportandrelatefindings over the different modalities
Yes
BI-RADS®reportingonexaminationandfindinglevel YesDesignated BI-RADS® reporting panel YesAutomatic compilation of structured reports according to BI-RADS®forefficientinformationsharing
Yes
Export of BI-RADS®reporttoPACS(SC,SR) YesAutomatic transfer of measurements into BI-RADS® report YesGeneratingkeyimages YesRendering of key images into the BI-RADS® report YesExportofkeyimagestoPACS YesAuto delete protection Yes
TheBreastUltrasoundReviewoptioncombinesmammographyandultrasoundforacomprehensiveandefficientreview.Italsoaddsthe BI-RADS®reportingfeatureforenhancedworkflow.
Ultrasound
Designated BI-RADS® reporting panel Yes
Hanging protocols • Tiled view (6 images per page including scrollingthroughpages)
• Runmode(enlargedimageswithscrollingoption)2D color display Yes3D volume reconstruction, multi-planar reformats Yes,forPhilipsUltrasoundonlyAdditional viewing tools • Zoom
• PanMeasurements • Transversalsize
• Antero-posteriorsize• Cranio-caudalsize
Show/hide measurement Yes
* Multi-modality options powered by IntelliSpace Clinical Applications
452296297571.indd 6 3-10-2013 9:18:31
7
IntelliSpace Breast* – Breast MRI Review option
The Breast MRI Review option is an addition to the Breast UltrasoundReviewoption.Itaddsthefunctionalityofthe breast diagnostic workstation with full MRI review functionality.
In addition to the previously mentioned functionality for mammography and ultrasound, the Breast MRI Review option adds the following:
MRI
Designated BI-RADS® reporting panel Yes
Automatictransferoffindingpositioninthebreastdiagram YesDisplayofacquiredsequences(originalimages) Yes3D volume rendering for MRI in color YesMulti-PlanarReformat(MPR) YesNavigation through single slices of volume YesLinkednavigationthroughslicesofdifferentMPRs YesNavigation through dynamic time points YesChoice of viewing subtracted or unsubtracted dynamics YesEnlarged viewing of selected breast YesMaximumIntensityProjection(MIP) YesPreventionofoverlapwhenfocusingononebreastlaterality YesLinkbetweentheregionofinterestintheMIPandthe correspondingsliceintheMPR
Yes
Display of time intensity curves for the selected region of interest YesAdditional viewing tools • Window width/window level
• Zoom• Pan• Switching between planes (sagittal, coronal,transversal)
• RollingMeasurements • Antero-posteriorsize
• Left-rightsize• Cranio-caudalsize• Largest diameter• Distance from skin• Distance from nipple• Distance from chest wall
Show/hide measurement Yes
452296297571.indd 7 3-10-2013 9:18:31
8
Hardware
ClientVendor name DellSystem type PrecisionworkstationT3600Chassis Mid-TowerProcessor Intel® Xeon®E5-1620(3.60GHz,10MCache,4C,130W)Memoryconfiguration 16GB1600MHz,DDR3,ECC,RDIMMMemory(4x4GB)CD-ROM/DVD 8xDVD+/-RWDriveHard drive #1 250GB35"SerialATA(7.2Krpm)HardDrive(NoRAID)Operating system English–Windows7ultimatex64SP1
ServerVendor name Dell®
System type T320Chassis Tower2.5"Chassiswithupto16HotPlugHardDrivesProcessor Intel® Xeon®E5-2430(15MCache,2.2GHz,7.2GT/s,Intel®QPI,6C,
95W)Memoryconfiguration 8GB(2x4GB),1333Mhz,RDIMM,lowvolt,DualRank,x8CD-ROM/DVD DVD+/-RWSATA,internalHard drives 8x500GBnear-lineSAS(7.200rpm)2.5"harddriveHotPlugImagesdatabasesize 2.6TBOperating system Windows®Server2008R2SP1StandardEdition(English)
Incl.5CALs
Mammography keypadUSBkeypad Philipsdesignedmammographykeypad,
backlight buttonsElectrical interfacing is done via 1 standard USB-2plug,cablelength1800mm(70.9˝)
Mammography workspace provides a dedicated mammography keypad for quick access to often-used functions to enhanceefficiencyandcomfortfortheuser.
• One-key access to common tools and functions
• Accommodates right and left handed users• The functionality includes simple navigation
through cases, the essential tools for mammography review, status buttons for workflowmanagement,andcustomizablekeys
Individualconfigurablekeysforeach user to improve speed
Yes, two keys on keypad are individually programmable
Mammography keypad
452296297571.indd 8 3-10-2013 9:18:32
9
Navigation monitorMonitor DellUltraSharpU2312HM/blackDisplay type Thinfilmtransistor(TFT)activematrixliquidcrystal
display(LCD)Paneltype e-IPS–InPlaneSwitching,Anti-glarewithhardcoat3HSize 23˝Dimensions(WxDxH) 546.4x185.4x365–493.9mm(21.51˝x7.30˝x14.37–
19.44˝)Panelresolution 1920x1080at60HzContrast ratio 1000:1(typical)Brightness 300 cd/m2(typical)Weight(standalone) 2.96kg(6.53lbs)Weight(includingpackaging) 6.40kg(14.11lbs)Powersupply VoltageRequired:100to240VAC/50or60Hz+3Hz/
1.5A(Max)Powerconsumption(Operational)
30W(typical)/70W(maximum)
Supplied accessories DVI–DVIcable;europowercable;USBupstreamcable
Color application monitorMonitor DellUltraSharpU3011Display type Thinfilmtransistor(TFT)Paneltype e-IPS–In-planeSwitching,antiglareSize 30˝Dimensions(WxDxH) 481.3mm(compressed)~571.3mm(extended)x694.5mmx
211.3mm[18.95˝(compressed)~22.50˝(extended)x27.34˝x8.32˝]
Panelresolution 2560x1600at60HzContrast ratio 1000:1(typical),DynamicContrastRatio:100,000:1(Max)Brightness 370 cd/m2(typical)Weight(standalone) 9.3kg(20.40lbs)Weight(includingpackaging) 15.3kg(33.76lbs)Powersupply ACinput:AC100–240V,50/60Hz,2.5APowerconsumption 110W(typical)/250W(maximum);<2W(standby/sleep)Supplied accessories DVI – DVI dual link cable; euro power cable
Navigation monitor
Color application monitor
452296297571.indd 9 3-10-2013 9:18:36
10
5MP Monitors Mammography: Barco Nio (optional)Display Nio5mpMDNG-6121Display technology TFTAMLCDDualDomainIPSNative resolution 2800x2100Active screen diagonal 541mm(21.3˝)Active screen width 324mm(12.8˝)Active screen height 432mm(17˝)Pixelpitch(HxV) 0.154mmMaximum luminance 1100 cd/m2
Luminance calibrated 500 cd/m²Luminanceuniformity(typical) <15%variationDisplayadjustmentcontrol Through QAWeb software or by OSD menuDisplay controls On/Off, OSDVideo signal input DVI-D Dual LinkDisplay communication DDC2Bi,USB2.0Sensor built-in BLOS backlight sensorCertificationsandstandards UL60601-11STEDITION,CAN/CSA-C22.2NO.601.1-M90,
IEC60601-12NDED:1988+A1:1991+A2:1995,IEC60950-1:20011STEDITION,CE-2004/108/EC,CE-93/42/EC,A1:2007/47/ECCLASSIIB,DEMKO-EN60601-1,CCC-GB9254-2008+GB4943-2001+GB17625.1-2003,BSMI-CNS13438(95)+CNS14336(94),KCC,VCCI,FCCclassB,FDA510K,Rohs
Operational temperature 0°Cto+35°C(32°Fto95°F)Powerconsumption 95 WWeight 12.3kg(27.12lbs)
5MP Monitors
452296297571.indd 10 3-10-2013 9:18:36
11
5MP Monitors Mammography: Barco Coronis (optional)Display MDMG-5121Display technology TFTAMLCDdualdomainIPSGrayscale,3subpixelsperpixelNative resolution 2048x2560pixelsActive screen diagonal 540.9mm(21.3˝)Active screen width 337.9mm(13.3˝)Active screen height 422.4mm(16.6˝)Pixelpitch 0.165mm(0.0065˝)Maximum luminance 1600 cd/m2
DICOM calibrated luminance Factorydefault600cd/m2
Luminance uniformity 90%typicalwithPPUStabilization,calibration,and automated QA
EmbeddedI-Guard
Digital video input DVI-D Dual LinkDisplay control and communication
DDC(complyingtoDDC2Bi)
Digital video/DDC inputconnector
One physical DVI connector, one cable
Display controls Poweron/off,backlightadjustments,OSDCertificationsandstandards UL60601-11stEdition,CAN/CSA-C2.2No.601.1-M90,IEC
60601-12ndED:1988+A1:1991+A2:1995,IEC60950-1:20011stEdition,CE-2004/108/EC,CE-93/42/EC,A1:2007/47/EC,ClassIIB,DEMKO-EN60601-1,CCC-GB9254-2008+GB4943-2001+GB17625-1-2003,BSMI-CNS13438(95)+CNS14336(94),KCC,VCCI,FCCclassB,FDA510K,RoHS
Operational temperature 0°Cto+35°C(32°Fto95°F)Powersupply ACinput:AC90–264V,45–65HzPowerconsumption 65W(nominal)Weight 13.5kg(29.7lb)
10 MP Monitors Mammography: Barco Coronis Fusion (optional)Display CoronisFusionDisplay technology TFTAMLCDDualDomainIPSNative resolution Native10MP(4096x2560),configurableto2x5MP(2048x2560)Active screen diagonal 762mm(29.6˝)Active screen width 403mm(15.9˝)Active screen height 432mm(17˝)Pixelpitch(HxV) 0.1575mmMaximum luminance 1250 cd/m2
Luminance calibrated 500 cd/m2
Video input signals DVI-DDualLink(2x)Certificationsandstandards
CE0120(MDD93/42/EECclassIIbproduct),CE-2004/108/EC,CE-93/42/EEC;A1:2007/47/ECclassIIb,UL60601-11STEDITION,CAN/CSA-C22.2NO.601.1-M90:2005,IEC60601-12NDED:1988+A1:1991+A2:1995,IEC60950-1:20052NDEDITION,DEMKO-EN60601-1:1990+A1:1993+A2:1995,VCCI,FCCclassB,BSMI,FDA510K,RoHS,KC
Powerconsumptionnominal
102 W
Weight 24.2kg(53.6lbs)
5MP Monitors
10MP Monitors
452296297571.indd 11 3-10-2013 9:18:38
12
DICOM pre-fetchingSoftware PACSGEARSweeperThe Sweeper application provides an automated method for on-demand pre-fetching of previous studies based on upcoming patient schedulesOvernight pre-fetching of priors based on DICOM modality worklist YesWalk-in’s – check off worklist updates YesConfigurablerulesforpre-fetchingofstudies Yes
Media Writer / CD-DVD RobotSoftware PACSGEARMediaWriterSWHardware PrimeraBravoSEMediaWriterisasoftware/hardwaresolutionthatoffersfast,one-clickburningfromtheIntelliSpaceBreast. BurnDICOMstudiesandreportstoCD/DVDorUSBflashdrivestocreateaportableimagerecord.Burn time per disc 3 minutesNumber of empty CD/DVD to prevent manual loading 20Viewer integrated to view studies and reports virtually anywhere YesBuilt-ininkjetprinterforaccuratelabelswithcustomizableinformation
Yes
Additional options
452296297571.indd 12 3-10-2013 9:18:39
Please visit www.philips.com/mammography
Philips Healthcare is part of Royal Philips Electronics
How to reach uswww.philips.com/[email protected]
Asia+4970314632254
Europe, Middle East, Africa+4970314632254
Latin America+551121250744
North America+142548770008002855585(tollfree,USonly)
Dell is a registered trademark of Dell Computer Corporation.WindowsisaregisteredtrademarkofMicrosoftCorporationintheUnitedStatesandothercountries.Othercompanyandproductnamesmay be trademarks of the respective companies with which theyareassociated.
©2013KoninklijkePhilipsElectronicsN.V.Allrightsarereserved.
PhilipsHealthcarereservestherighttomakechangesinspecificationsand/ortodiscontinueanyproductatanytimewithoutnoticeor obligationandwillnotbeliableforanyconsequencesresultingfromtheuseofthispublication.
PrintedinTheNetherlands.452 962 97571 * OCT 2013
452296297571.indd 14 3-10-2013 9:18:39