explosionproof meter housings - adalet...window cover ul 1203 csa c22.2 no. 25 & 30 ul 50...

9
4801 West 150th Street, Cleveland, Ohio 44135 TEL 216.267.9000 FAX 216.267.1681 [email protected] 143 EXPLOSIONPROOF Meter Housings XJDGCH N4 XJDFGCH N4 4 1/8” x 4 1/8” X 3” XJMCGCH N4 6 3/4” x 6 3/4” x 3” XJTGCH N4 XJTFGCH N4 5 13/16” x 6 9/16” x 4” XJMGCH N4 6 3/4” x 6 3/4” x 8” XJMAGCH N4 6 3/4” x 6 3/4” x 5” XJHBGCH N4 7 1/4” x 9 1/8” x 6” XJHAGCH N4 7 3/16” x 9 3/16” x 4” XJNGCH N4, 6 & 12 11 1/2” x 12 3/4” x 6” 11 1/2” x 12 3/4” x 12 1/8” XJLGCH N4 6” X 6” x 3 9/16” XJXGCH N4 4 7/8” x 4 7/8” x 3 1/16” XJWHGCH N4 6 7/8” I.D. x 4 1/4” Cover Opening 6 7/8”” XJKAGCH N4 9 1/2” x 11 1/2” x 8 1/2” XJKGCH N4 9 1/5” x 11 1/2” x 6 1/8” XJHCGCH N4 7 3/4’ x 10 5/16” x 5” XJWTGCH N4 5 3/8” I.D. x 3 3/4” Cover Opening 5 3/8” EXPLOSIONPROOF METER HOUSINGS WINDOW COVER UL 1203 CSA C22.2 No. 25 & 30 UL 50 Certifications Class I, Groups B,C,D Class II, Groups E,F,G TYPE 4 • Drilled and tapped to specification, attach layout sheet. • Dimensions are internal. Explosionproof Meter Housings -Window Screw Cover

Upload: others

Post on 24-Mar-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Explosionproof Meter Housings - Adalet...WINDOW COVER UL 1203 CSA C22.2 No. 25 & 30 UL 50 Certifications Class I, Groups B,C,D Class II, Groups E,F,G TYPE 4 • Drilled and tapped

4801 West 150th Street, Cleveland, Ohio 44135 TEL 216.267.9000 FAX 216.267.1681 [email protected] 143

EX

PL

OS

ION

PR

OO

F

Meter H

ousings

EX

PL

OS

ION

PR

OO

F

Met

er H

ousi

ngs

XJDGCH N4XJDFGCH N4

41/8”x41/8”X3”

XJMCGCH N463/4”x63/4”x3”

XJTGCH N4XJTFGCH N4

513/16”x69/16”x4”

XJMGCH N463/4”x63/4”x8”

XJMAGCH N463/4”x63/4”x5”

XJHBGCH N471/4”x91/8”x6”

XJHAGCH N473/16”x93/16”x4”

XJNGCH N4, 6 & 12111/2”x123/4”x6”

111/2”x123/4”x121/8”

XJLGCH N46”X6”x39/16”

XJXGCH N447/8”x47/8”x31/16”

XJWHGCH N467/8”I.D.x41/4”

CoverOpening67/8””

XJKAGCH N491/2”x111/2”x81/2”

XJKGCH N491/5”x111/2”x61/8”

XJHCGCH N473/4’x105/16”x5”

XJWTGCH N453/8”I.D.x33/4”

CoverOpening53/8”

EXPLOSIONPROOF METER HOUSINGS

WINDOW COVER

UL1203

CSAC22.2No.25&30

UL50

Certifications

ClassI,GroupsB,C,D

ClassII,GroupsE,F,G

TYPE4

• Drilledandtappedtospecification,attachlayoutsheet. • Dimensionsareinternal.

Explosionproof Meter Housings-Window Screw Cover

Page 2: Explosionproof Meter Housings - Adalet...WINDOW COVER UL 1203 CSA C22.2 No. 25 & 30 UL 50 Certifications Class I, Groups B,C,D Class II, Groups E,F,G TYPE 4 • Drilled and tapped

The ADALET Engineering Department is Available to Assist you in the Selection of Enclosures and Accessories.144

EX

PL

OS

ION

PR

OO

F

Meter H

ousings

EX

PL

OS

ION

PR

OO

F

Met

er H

ousi

ngs

EXPLOSIONPROOF METER HOUSINGS

WINDOW COVER

Explosionproof Meter Housings-Window Screw Cover

XJDGCHX N4XJDFGCHX N441/8”x41/8”x3”

XJMCGCHX N463/4”x63/4”x3”

XJTGCHX N4XJTFGCHX N4

513/16”x69/16”x4”

XJMGCHX N463/4”x63/4”x8”

XJMAGCHX N463/4”x63/4”x5”

XJHBGCHX N471/4”x91/8”x6”

XJHAGCHX N473/16”x93/16”x4”

XJNGCHX N4, 6 & 12111/2”x123/4”x6”

111/2”x123/4”x121/8”

XJLGCHX N46”x6”x39/16”

XJXGCHX N447/8”x47/8”x31/16”

XJWHGCHX N467/8”I.D.x41/4”

CoverOpening67/8””

XJKAGCHX N491/2”x111/2”x81/2”

XJKGCHX N491/5”x111/2”x61/8”

XJHCGCHX N473/4’x105/16”x5”

XJWTGCHX N453/8”I.D.x33/4”

CoverOpening53/8”

• Drilledandtappedtospecification,attachlayoutsheet. • Dimensionsarenominalinternal.

UL1203

CSAC22.2No.25&30

UL60079-0/UL60079-1

CSA60079-0/CSA60079-1

ATEXDirective94/9/EC

EN50014,EN50018

IEC60529

UL50

Certifications

ClassI,GroupsB,C,D

ClassII,GroupsE,F,G

ClassIII

ClassI,Zone1,AExdIIB+H2

ExdIIB+H2

0539II2GD(Optional)*

EExdIIB+H2(Optional)*

IP66

TYPE4

*specifyATEXorIECExifrequired

Page 3: Explosionproof Meter Housings - Adalet...WINDOW COVER UL 1203 CSA C22.2 No. 25 & 30 UL 50 Certifications Class I, Groups B,C,D Class II, Groups E,F,G TYPE 4 • Drilled and tapped

4801 West 150th Street, Cleveland, Ohio 44135 TEL 216.267.9000 FAX 216.267.1681 [email protected] 145

EX

PL

OS

ION

PR

OO

F

Meter H

ousings

EX

PL

OS

ION

PR

OO

F

Met

er H

ousi

ngs

3 4 1⁄8

6 3⁄16

5 3⁄84 1⁄16

5 1⁄83 ¾

5 1⁄84 1⁄8

6 ¼

6 ½5 3⁄84 7⁄8

6 ¾

9 1⁄8

5 ¼ 7 ¾

7 ¾6 ¾

4

6 5⁄84 1⁄84 13⁄16

6 13⁄167 ¾

5 13⁄16

7 9⁄16

6 9⁄166

EXPLOSIONPROOF METER HOUSINGS

WINDOW COVER

XJDFGCH N4XJDFGCHX N4

XJMCGCH N4XJMCGCHX N4

XJTFGCH N4XJTFGCHX N4

NOMINAL DIMENSIONS

Max Nominal Inside Dimensions Dims Throat Max Mounting Weight Catalog Conduit Under Opening Meter Hole Each # Size W L D Glass Face Dia. Size Pounds

XJDFGCH N4 2 4 1/8 4 1/8 3 4 1/16 2 7/8 3 1/2 7/16 6

XJDGCH N4 2 4 1/8 4 1/8 3 4 1/16 3 3/4 3 1/2 7/16 6

XJMCGCH N4 2 6 3/4 6 3/4 3 4 5/8 7 5 1/4 7/16 17

XJTFGCH N4 2 5 13/16 6 9/16 4 4 11/16 5 3/8 4 1/2 1/2 13

FEATURES

• Copper-freealuminumcastingdesignedforspecificsizeinstruments

andmeters.

• XJDFGCH:Designedforthemountingof31/2”roundinstruments andmeters.Furnishedwithanintegrallycastinsidemountingflange. AlsoavailablewithouttheflangeastheTypeXJDGC(X),forequipment otherthan31/2”roundinstrumentsandmeters.

• XJTFGCH:Designedfor41/2”roundand31/2”rectangularmeters. Furnishedwithcastinsidemountingearsandadapterplatefor metermounting.

• Optionalmountingpansavailable.

UL1203

CSAC22.2No.25&30

UL50

Certifications

ClassI,GroupsB,C,D

ClassII,GroupsE,F,G

TYPE4

Explosionproof Meter Housings-Window Screw Cover

Page 4: Explosionproof Meter Housings - Adalet...WINDOW COVER UL 1203 CSA C22.2 No. 25 & 30 UL 50 Certifications Class I, Groups B,C,D Class II, Groups E,F,G TYPE 4 • Drilled and tapped

The ADALET Engineering Department is Available to Assist you in the Selection of Enclosures and Accessories.146

EX

PL

OS

ION

PR

OO

F

Meter H

ousings

EX

PL

OS

ION

PR

OO

F

Met

er H

ousi

ngs

EXPLOSIONPROOF METER HOUSINGS

WINDOW COVER

XJMGCH N4XJMGCHX N4

XJMAGCH N4XJMAGCHX N4

6 ¼

4 1⁄16

9 7⁄811 ½

7 ¾6 ¾

9 1⁄8

7 ¾6 ¾

5 ¼

FEATURES

• Copper-freealuminumcastingdesignedforspecificsizeinstruments andmeters.

• Optionalmountingpansavailable.

NOMINAL DIMENSIONS

Max Nominal Inside Dimensions Dims Throat Max Mounting Weight Catalog Conduit Under Opening Meter Hole Each # Size W L D Glass Face Dia. Size Pounds

XJMGCH N4 2 6 3/4 6 3/4 8 9-7/8 5 3/8 5 1/4 7/16 22

XJMAGCH N4 2 6 3/4 6 3/4 5 6-7/8 5 3/8 5 1/4 7/16 19

UL1203

CSAC22.2No.25&30

UL50

Certifications

ClassI,GroupsB,C,D

ClassII,GroupsE,F,G

TYPE4

6 ¼

4 1⁄166 7⁄8 8 ½

7 ¾6 ¾

9 1⁄8

7 ¾6 ¾

5 ¼

Explosionproof Meter Housings-Window Screw Cover

Page 5: Explosionproof Meter Housings - Adalet...WINDOW COVER UL 1203 CSA C22.2 No. 25 & 30 UL 50 Certifications Class I, Groups B,C,D Class II, Groups E,F,G TYPE 4 • Drilled and tapped

4801 West 150th Street, Cleveland, Ohio 44135 TEL 216.267.9000 FAX 216.267.1681 [email protected] 147

EX

PL

OS

ION

PR

OO

F

Meter H

ousings

EX

PL

OS

ION

PR

OO

F

Met

er H

ousi

ngs

6 ¾

3 ¾ 5 3⁄16

5 ¾

4 7⁄8

4 ¾

3

4 7⁄85 ¾

5 ¼

5 7⁄8

764

8 ¼

6

7

4 1⁄8

EXPLOSIONPROOF METER HOUSINGS

WINDOW COVER

XJXGCH N4XJXGCHX N4

XJLGCH N4XJLGCHX N4

XJTGCH N4XJTGCHX N4

NOMINAL DIMENSIONS

Max Nominal Inside Dimensions Cover Window Mounting Weight Catalog Conduit Opening Opening Hole Each # Size W L D Size Pounds

XJXGCH N4 2 4 7/8 4 7/8 3 1/16 3 3/4 4 3/4 11/32 6 1/2

XJLGCH N4 2 6 6 3 9/16 4 1/8 5 3/8 7/16 11

XJTGCH N4 2 5 13/16 6 9/16 4 4 11/16 5 3/8 1/2 13

FEATURES

• Copper-freealuminumcasting.

• Thisseriesofhousingswithglasswindowsaresuitableformounting relaysandcontrolequipmentaswellasmetersandinstruments.

• Thewallsectionofthehousingsareofsufficientthicknesstoprovide therequired(5)fullthreadsforconduitentrancesaslisted.

• Thehousingsarestockedblankandcanbedrilledandtappedtoyour specifications.(Alayoutsketchshouldaccompanytheorder.)

• Mountingposts,rings,studsandotheraccessoriescanbefurnished.

• Optionalmountingpansavailable.

UL1203

CSAC22.2No.25&30

UL50

Certifications

ClassI,GroupsB,C,D

ClassII,GroupsE,F,G

TYPE4

6 9⁄16

6 7⁄16

4

7 ¾

6

4 11⁄16

5 13⁄16

6 11⁄16

7 7⁄16

Explosionproof Meter Housings-Window Screw Cover

Page 6: Explosionproof Meter Housings - Adalet...WINDOW COVER UL 1203 CSA C22.2 No. 25 & 30 UL 50 Certifications Class I, Groups B,C,D Class II, Groups E,F,G TYPE 4 • Drilled and tapped

The ADALET Engineering Department is Available to Assist you in the Selection of Enclosures and Accessories.148

EX

PL

OS

ION

PR

OO

F

Meter H

ousings

EX

PL

OS

ION

PR

OO

F

Met

er H

ousi

ngs

EXPLOSIONPROOF METER HOUSINGS

WINDOW COVER

XJHAGCH N4XJHAGCHX N4

XJHBGCH N4XJHBGCHX N4

XJHCGCH N4XJHCGCHX N4

9 ¾

10 3⁄16

6 7⁄16

9 3⁄16

8 3⁄16

7 3⁄16

8 ¾

5 ¼

4 5⁄8

FEATURES

• Copper-freealuminumcasting.

• Thisseriesofhousingswithglasswindowsaresuitableformounting relaysandcontrolequipmentaswellasmetersandinstruments.

• Thewallsectionofthehousingsareofsufficientthicknesstoprovidethe required(5)fullthreadsforconduitentrancesaslisted.

• Thehousingsarestockedblankandcanbedrilledandtappedtoyour

specifications.(Alayoutsketchshouldaccompanytheorder.)

• Mountingposts,rings,studsandotheraccessoriescanbefurnished.

• Optionalmountingpansavailable.

NOMINAL DIMENSIONS

Max Nominal Inside Dimensions Dims Dia. Mounting Weight Catalog Conduit Under Cover Hole Each # Size W L D Glass Opening Size Pounds

XJHAGCH N4 2 7 3/16 9 3/16 4 4 5/8 7 9/16 17

XJHBGCH N4 2 7 1/4 9 1/8 6 6 9/16 7 9/16 23

XJHCGCH N4 2 7 3/4 10 5/16 5 5 11/16 7 9/16 23

UL1203

CSAC22.2No.25&30

UL50

Certifications

ClassI,GroupsB,C,D

ClassII,GroupsE,F,G

TYPE4

9 ¾

6 9⁄16 8 ½

10 ¼

8 3⁄8

7 ¼

8 7⁄8

5 ¼

9 1⁄8

10 ¼

5 11⁄16 7 9⁄16

11 7⁄16

8 7⁄8

7 ¾

7 ¾

5 ¼

10 5⁄16

Explosionproof Meter Housings-Window Screw Cover

Page 7: Explosionproof Meter Housings - Adalet...WINDOW COVER UL 1203 CSA C22.2 No. 25 & 30 UL 50 Certifications Class I, Groups B,C,D Class II, Groups E,F,G TYPE 4 • Drilled and tapped

4801 West 150th Street, Cleveland, Ohio 44135 TEL 216.267.9000 FAX 216.267.1681 [email protected] 149

EX

PL

OS

ION

PR

OO

F

Meter H

ousings

EX

PL

OS

ION

PR

OO

F

Met

er H

ousi

ngs

EXPLOSIONPROOF METER HOUSINGS

WINDOW COVER

FEATURES

• Copper-freealuminumcasting.

• Largecoveropeningenhancesmountingpaninstallation.

• Availabilityoftwodepthsoffersaselectionforefficientpackagingof components.

• Suitableformountingrelaysandcontrolequipmentaswellasmeters andinstruments.

• Thewallsectionofthehousingsareofsufficientthicknesstoprovide therequired(5)fullthreadsforconduitentrancesaslisted.

• Theboxesaredrilledandtappedtospecification.(Alayoutsketch shouldbeattachedtoeachorder.)

• Mountingposts,rings,studsandotheraccessoriescanbefurnished.

• Optionalmountingpansavailable.

XJNGCH N4XJNGCHX N4

NOMINAL DIMENSIONS

Max Nominal Inside Dimensions Overall Cover Window Mounting Weight Catalog Conduit Height Opening Opening Hole Each # Size W L D Size Pounds

XJNGCH6 N4 2 11 1/2 12 3/4 6 9 13/16 10 3/4 8 5/8 63

XJNGCH12 N4 2 11 1/2 12 3/4 12 1/8 15 15/16 10 3/4 8 5/8 87

UL1203

CSAC22.2No.25&30

UL50

Certifications

ClassI,GroupsB,C,D

ClassII,GroupsE,F,G

TYPE4

14 3⁄8

11 ½

8 12 ¾

16 ¾

10 ¾13 1⁄8

8

Explosionproof Meter Housings-Window Screw Cover

Page 8: Explosionproof Meter Housings - Adalet...WINDOW COVER UL 1203 CSA C22.2 No. 25 & 30 UL 50 Certifications Class I, Groups B,C,D Class II, Groups E,F,G TYPE 4 • Drilled and tapped

The ADALET Engineering Department is Available to Assist you in the Selection of Enclosures and Accessories.150

EX

PL

OS

ION

PR

OO

F

Meter H

ousings

EX

PL

OS

ION

PR

OO

F

Met

er H

ousi

ngs

10 ¾

12 ¾

8 7⁄8

11 ½

10 15⁄16

6 11⁄16

8

9 ½ 12 3⁄8

EXPLOSIONPROOF METER HOUSINGS

WINDOW COVER

XJKGCH N4XJKGCHX N4

XJKAGCH N4XJKAGCHX N4

10 ¾

12 ¾

6 7⁄8

11 ½

8 15⁄16

6 11⁄16

8

9 ½ 12 3⁄8

UL1203

CSAC22.2No.25&30

UL50

Certifications

ClassI,GroupsB,C,D

ClassII,GroupsE,F,G

TYPE4

FEATURES

• Copper-freealuminumcasting.

• Thisseriesofhousingswithglasswindowsaresuitableformounting relaysandcontrolequipmentaswellasmetersandinstruments.

• Thewallsectionofthehousingsareofsufficientthicknesstoprovidethe required(5)fullthreadsforconduitentrancesaslisted.

• Thehousingsarestockedblankandcanbedrilledandtappedtoyour

specifications.(Alayoutsketchshouldaccompanytheorder.)

• Mountingposts,rings,studsandotheraccessoriescanbefurnished.

• Optionalmountingpansavailable.

NOMINAL DIMENSIONS [XJKGCH & XJKAGCH]

Max Nominal Inside Dimensions Dims. Dia. Mounting Weight Catalog Conduit Under Cover Hole Each # Size W L D Glass Opening Size Pounds

XJKGCH N4 4 9 1/2 11 1/2 6 1/8 6 7/8 9 9/16 39 1/2

XJKAGCH N4 4 9 1/2 11 1/2 8 1/2 8 7/8 9 9/16 43 1/2

Explosionproof Meter Housings-Window Screw Cover

Page 9: Explosionproof Meter Housings - Adalet...WINDOW COVER UL 1203 CSA C22.2 No. 25 & 30 UL 50 Certifications Class I, Groups B,C,D Class II, Groups E,F,G TYPE 4 • Drilled and tapped

4801 West 150th Street, Cleveland, Ohio 44135 TEL 216.267.9000 FAX 216.267.1681 [email protected] 151

EX

PL

OS

ION

PR

OO

F

Meter H

ousings

EX

PL

OS

ION

PR

OO

F

Met

er H

ousi

ngs

EXPLOSIONPROOF METER HOUSINGS

WINDOW COVER

Explosionproof Meter Housings-Window Screw Cover

NOMINAL DIMENSIONS [XJWHGCH & XJWTGCH)

Max Nominal Inside Dimensions Diameter Mounting Weight Catalog Conduit Cover Hole Each # Size DIA D Opening Size Pounds

XJWHGCH N4 2 1/2 6 7/8 4 1/4 6 7/8 7/16 9

XJWTGCH N4 2 5 3/8 3 3/4 5 3/8 3/8 8

NOMINAL DIMENSIONS [XJWHGCH & XJWTGCH)

Catalog # A B C D E F G H J K L

XJWHGCH N4 7 3/4 7 3/4 6 3/8 6 3/8 7/16 5 5/8 4 9/16 1 13/16 1 3/4 7 7/8 5 1/4

XJWTGCH N4 6 1/4 6 1/4 5 1/8 5 1/8 3/8 5 1/8 4 1 1/2 1 7/16 6 3/8 4

UL1203

CSAC22.2No.25&30

UL50

Certifications

ClassI,GroupsB,C,D

ClassII,GroupsE,F,G

TYPE4

A

E

C

BD

H

G

K

JF

L

FEATURES

• Copper-freealuminumcasting.

• Thisseriesofhousingswithglasswindowsaresuitableformounting relaysandcontrolequipmentaswellasmetersandinstruments.

• Thewallsectionofthehousingsareofsufficientthicknessto providetherequired(5)fullthreadsforconduitentrancesaslisted.

• Thehousingsarestockedblankandcanbedrilledandtappedtoyour specifications.(Alayoutsketchshouldaccompanytheorder.)

• Mountingposts,rings,studsandotheraccessoriescanbefurnished.

• Optionalmountingpansavailable.

XJWHGCH N4XJWHGCHX N4