f 056 057 x w x d operation range cooling heating cooling/heating cooling heating cooling/heating...

2
Slim Duct Specifications Power Source Capacity Input Power EER - Energy Class COP - Energy Class Running Current Moisture Removal Noise (Indoor) Noise (Outdoor) Airflow Rate (High) Piping Connections (Small / Large) Drain Pipe Diameter (I.D./O.D.) Max Pipe Length (Pre-Charge) Height Difference Refrigerant Net Dimension H x W x D Operation Range Cooling Heating Cooling/Heating Cooling Heating Cooling/Heating Cooling Heating Cooling Indoor/Outdoor Indoor Outdoor Cooling m °CDB kg(lbs) mm kg(lbs) mm mm mm dB(A) kW kW W/W A I/h m 3 /h V/Ø/Hz ARYG14LLTB AOYG14LA 198x700x620 19(42) 578x790x300 40(88) 6.35/12.70 25/32 25(15) 15 -10~46 -15~24 R410A 230/1/50 4.30 5.00 1.33/1.34 3.21-A 3.71-A 6.1/6.1 1.5 32/30/28/26 49 800/1910 ARYG18LLTB AOYG18LA 198x900x620 23(51) 578x790x300 40(88) 6.35/12.70 25/32 25(15) 15 -10~46 -15~24 R410A 230/1/50 5.20 6.00 1.62/1.66 3.21-A 3.61-A 7.2/7.4 2.0 32/30/29/27 50 940/2000 Model No. Indoor unit Outdoor unit ARYG12LLTB ARYG14LLTB CLASS A ALL DC CLASS A ALL DC ARYG18LLTB CLASS A ALL DC Wired R.C. Slim design with drain pump Increase static pressure range Dual concealed type Slim design Drain port This model is slim design, it can install at the place where a ceiling is narrow. Drain pump built-in Height 198mm Drain pump Flexible installation Floor concealed Ceiling concealed Compact Outdoor Unit ARYG12LLTB AOYG12LA 230/1/50 3.50 4.10 1.05/1.11 3.33-A 3.69-A 4.8/5.1 1.3 29/28/26/25 47 650/1780 198x700x620 19(42) 578x790x300 40(88) 6.35/9.52 25/32 25(15) 15 -10~46 -15~24 R410A H/M/L/Q

Upload: ngoduong

Post on 19-May-2018

230 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: F 056 057 x W x D Operation Range Cooling Heating Cooling/Heating Cooling Heating Cooling/Heating Cooling Heating Cooling Indoor/Outdoor Indoor Outdoor Cooling m CDB kg(lbs) mm kg(lbs)

Slim Duct

Specifications Dimensions Models: (Unit : mm)ARYG12LLTB / ARYG14LLTB / ARYG18LLTB

Power Source

Capacity

Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)

Piping Connections (Small / Large)Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Height Difference

Refrigerant

Net Dimension H x W x D

OperationRange

CoolingHeating

Cooling/HeatingCoolingHeating

Cooling/Heating

CoolingHeating

CoolingIndoor/Outdoor

Indoor

Outdoor

Cooling

m

°CDB

kg(lbs)mm

kg(lbs)mmmm

mm

dB(A)

kW

kW

W/W

AI/h

m3/h

V/Ø/Hz

ARYG14LLTB

AOYG14LA

198x700x620

19(42)578x790x300

40(88)6.35/12.70

25/3225(15)

15-10~46-15~24R410A

230/1/504.305.00

1.33/1.343.21-A3.71-A6.1/6.1

1.5 32/30/28/26

49800/1910

ARYG18LLTB

AOYG18LA

198x900x620

23(51)578x790x300

40(88)6.35/12.70

25/3225(15)

15-10~46-15~24R410A

230/1/505.206.00

1.62/1.663.21-A3.61-A7.2/7.4

2.0 32/30/29/27

50940/2000

Model No.Indoor unit

Outdoor unit

ARYG12LLTB ARYG14LLTB

CLASSA

ALLDC

CLASSA

ALLDC

ARYG18LLTB

CLASSA

ALLDC

Optional parts

Wired Remote Controller:Simple Remote Controller:IR Receiver Unit:Remote Sensor Unit:External Control Set:Auto Louver Grille Kit:

UTY-RNNYMUTY-RSNYMUTY-LRHYMUTY-XSZXUTD-ECS5AUTD-GXSA-W (For ARYG12 / 14LLTB)

UTD-GXSB-W (For ARYG18LLTB)

*Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size.

Wired R.C.

• Slim design with drain pump• Increase static pressure range• Dual concealed type

(Bol

t pitc

h)

F51

152

377

174

713030

ABCD

EF

700650734650

P100x6=600574

ARYG12 / 14LLTB900850934850

P100x8=800774

ARYG18LLTB

78

50

EDC

(Bolt pitch)

43

20

198

168

78

BA

12

69144263371

620

47557889119

167

Air-intake

Back sideBottom side

Air intake direction can be selected to match the installation site.

Slim design

Drain port

This model is slim design, it can install at the place where a ceiling is narrow.

Drain pumpbuilt-in

Height198mm

Drain pump

Drain hose is standard accessory

Max.850mm

Filter (Accessory) Filter (2pcs.)

Flexible installation

Floor concealed

Ceiling concealed

Auto Louver Grille Kit (Option)

Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior.

Drain pump is standard accessory

It allows flexible installation.

Selectable with a wide range of static pressure

By using DC fan motor, it is possible to change the static pressure range0 to 90Pa. The change of static pressure range is possible by remote controller.

Static pressure range0 to 90 Pa

Wired RemoteController

Wireless RemoteController

4 steps selectable and auto swing

Auto Louver Grille Duct type

Compact Outdoor Unit

ARYG12LLTB

AOYG12LA

230/1/503.504.10

1.05/1.113.33-A3.69-A4.8/5.1

1.3 29/28/26/25

47650/1780

198x700x620

19(42)578x790x300

40(88)6.35/9.52

25/3225(15)

15-10~46-15~24R410A

H/M/L/Q

Page 2: F 056 057 x W x D Operation Range Cooling Heating Cooling/Heating Cooling Heating Cooling/Heating Cooling Heating Cooling Indoor/Outdoor Indoor Outdoor Cooling m CDB kg(lbs) mm kg(lbs)

Slim Duct

Specifications Dimensions Models: (Unit : mm)ARYG12LLTB / ARYG14LLTB / ARYG18LLTB

Power Source

Capacity

Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)

Piping Connections (Small / Large)Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Height Difference

Refrigerant

Net Dimension H x W x D

OperationRange

CoolingHeating

Cooling/HeatingCoolingHeating

Cooling/Heating

CoolingHeating

CoolingIndoor/Outdoor

Indoor

Outdoor

Cooling

m

°CDB

kg(lbs)mm

kg(lbs)mmmm

mm

dB(A)

kW

kW

W/W

AI/h

m3/h

V/Ø/Hz

ARYG14LLTB

AOYG14LA

198x700x620

19(42)578x790x300

40(88)6.35/12.70

25/3225(15)

15-10~46-15~24R410A

230/1/504.305.00

1.33/1.343.21-A3.71-A6.1/6.1

1.5 32/30/28/26

49800/1910

ARYG18LLTB

AOYG18LA

198x900x620

23(51)578x790x300

40(88)6.35/12.70

25/3225(15)

15-10~46-15~24R410A

230/1/505.206.00

1.62/1.663.21-A3.61-A7.2/7.4

2.0 32/30/29/27

50940/2000

Model No.Indoor unit

Outdoor unit

ARYG12LLTB ARYG14LLTB

CLASSA

ALLDC

CLASSA

ALLDC

ARYG18LLTB

CLASSA

ALLDC

Optional parts

Wired Remote Controller:Simple Remote Controller:IR Receiver Unit:Remote Sensor Unit:External Control Set:Auto Louver Grille Kit:

UTY-RNNYMUTY-RSNYMUTY-LRHYMUTY-XSZXUTD-ECS5AUTD-GXSA-W (For ARYG12 / 14LLTB)

UTD-GXSB-W (For ARYG18LLTB)

*Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size.

Wired R.C.

• Slim design with drain pump• Increase static pressure range• Dual concealed type

(Bol

t pitc

h)

F51

152

377

174

713030

ABCD

EF

700650734650

P100x6=600574

ARYG12 / 14LLTB900850934850

P100x8=800774

ARYG18LLTB

78

50

EDC

(Bolt pitch)

43

20

198

168

78

BA

12

69144263371

620

47557889119

167

Air-intake

Back sideBottom side

Air intake direction can be selected to match the installation site.

Slim design

Drain port

This model is slim design, it can install at the place where a ceiling is narrow.

Drain pumpbuilt-in

Height198mm

Drain pump

Drain hose is standard accessory

Max.850mm

Filter (Accessory) Filter (2pcs.)

Flexible installation

Floor concealed

Ceiling concealed

Auto Louver Grille Kit (Option)

Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior.

Drain pump is standard accessory

It allows flexible installation.

Selectable with a wide range of static pressure

By using DC fan motor, it is possible to change the static pressure range0 to 90Pa. The change of static pressure range is possible by remote controller.

Static pressure range0 to 90 Pa

Wired RemoteController

Wireless RemoteController

4 steps selectable and auto swing

Auto Louver Grille Duct type

Compact Outdoor Unit

ARYG12LLTB

AOYG12LA

230/1/503.504.10

1.05/1.113.33-A3.69-A4.8/5.1

1.3 29/28/26/25

47650/1780

198x700x620

19(42)578x790x300

40(88)6.35/9.52

25/3225(15)

15-10~46-15~24R410A

H/M/L/Q