f l o w me a s u r e me n t - flowmaster.com.br · f aci l i t i es and i n t he mai n process i...

20
www.flowmaster.com.br FLOW MEASUREMENT INSTRUMENTATION

Upload: others

Post on 04-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

ww

w.fl

owm

aste

r.com

.br

FLOW MEASUREMENT

INSTRUMENTATION

Page 2: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

Since its foundation in 1987, F. Master has been designing and manufacturing valvesand primary elements for differential pressure (DP) flow measurement. Supplying effective flow measurement equipment that meet international standardsand having a team with deep industry experience has made us a reliable partner to ourcustomers from different countries. F. Master meter tubes and orifice fittings are currently in many offshore productionfacilities and in the main process industries of Latin America. We have provided valvesand flow meters to large and small companies across a variety of industries. With an area of 10,000 m² (107,639 ft²), we have a complete structure that goes fromproduction to logistics, with machines and high performance equipment, besideshaving a highly trained technical team that aims to meet requirements and exceedexpectations of the national and international markets. We are an ISO 9001:2015 Certified Company.

IndustriesOil & Gas | Chemical & Petrochemical

Pulp & Paper | Sugar & Alcohol Food & Beverages

About Us

Page 3: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

Product Categories Orifice Fittings ........................................... 4 Flow Measurement .................................... 5-11 Flow Measurement Systems ..................... 12 Accessories ............................................... 13-17 Valves ........................................................ 18 Fittings ....................................................... 19

3www.flowmaster.com.br

Count on us to define the best measurementsolution for your application. F. Master has a complete line of primaryelements for differential pressure flowmeasurement, valves and accessories. F. Master's flow meters are designed to provideaccurate measurements, even in the mostchallenging operating environments, to meet thedemands of different applications to severalindustries.

Contents

Page 4: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

With the O-ring seal system, there is no needfor lubrication.

The Dual Chamber Orifice Fitting has beendeveloped by F. Master to meet Orifice Plateinspections without interrupting the flow.

Designed and produced to meet the ISO 5167,AGA-3, ASME B16.5, ASME B16.34 and MSSSP-55 Standards.

Single Chamber Orifice Fittings provide easyremoval of the plate relative to an orificeflange measurement assembly.

DUAL CHAMBER

SINGLE CHAMBER

Materials: Carbon Steel, Stainless Steel, Duplex. Others on request.

Materials in conformity with ASTMStandard, certificated.

Orifice Fittings

4 www.flowmaster.com.br

Materials: Carbon Steel, Stainless Steel, Duplex. Others on request.

Page 5: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

The FlowMeter has been developed to allowthe removal and insertion of the Orifice Plate,with speed and quality, facilitating its operationin the field, without the need of disassembly ofthe pipe. It has a pressure tap and a drain in its body.One of the advantages is the elimination oforifice flanges and cases, reducing costs andimproving maintenance.

According to AGA, ISO, ASME Standards. Materials: Carbon Steel, Stainless Steel, Duplex. Others on request.

FLOWMETER

F. Master's Flow-Cone flow meter is anadvanced differential pressure instrument thatprovides accuracy of ±0.5% of rate over a 10:1flow range. A key feature of this device is itsability to fit into small spaces while offering highlevels of accuracy and repeatability.

FLOWCONE

Designed for mild to harsh operating environments, and for a variety of fluids such asliquid, steam or gas where accuracy, low maintenance and cost are important, thisadvanced flow meter stands out from other flow technologies.According to ISO 5167 Standard. Materials: Carbon Steel, 304/316 Stainless Steel, Duplex, Super Duplex, Alloy Steel.Others on request.

Flow Measurement

5www.flowmaster.com.br

Page 6: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

The Wedge meter is designed formeasurements of high viscosity fluids andsolids in suspension. It can be supplied with differential pressuretaps for diaphragm seals, thus avoidingproblems of fluid inlays near the taps.

Manufactured for many situations, its application is aimed at 1/2" to 24" diameter lines.According to ISO 5167 Standard. Materials: Carbon Steel, 304/316 Stainless Steel, Duplex, Super Duplex, Alloy Steel.Others on request.

WEDGE

The Venturi Tube is suitable forapplications where minimal pressureloss is required, such as in watertreatments, combustion airmeasurements and especially liquidswith solids in suspension.

VENTURI TUBE

Materials: Carbon Steel, 304/316 Stainless Steel, Duplex, Super Duplex, Alloy Steel.Others on request.

The design consists of a convergent cone section,cylindrical bore, and a divergent cone section.According to ISO 5167 Standard.

Flow Measurement

6 www.flowmaster.com.br

Page 7: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

Based on the Pitot Tube principle, the MeasurementProbe is designed for flow measurements withnegligible load loss and accuracy of ± 1.5% at thebottom of the scale, and can reach below 0.5%calibrated in specialized laboratories. Installed inhorizontal and vertical lines. Materials: 316 Stainless Steel. Others on request.

MEASUREMENT PROBE

Flow Measurement

The Flow Nozzle has its characteristic inbetween the Orifice Plate and Venturi Tube.The Flow Nozzle format allows its applicationin services that the fluid is abrasive andcorrosive. Its main use is for steam flow in criticalconditions of operation (high speed,temperature and pressure).

There are two types of standard Flow Nozzles, type "ASME" and type "ISA".The main difference between them is the inlet radius profile and the pressure tapstypes, where "ASME" uses the Radius Taps (1D-1 / 2D) standard on the tube, and"ISA" uses the Corner Taps in piezometric rings welded together to the nozzle. Materials: Carbon Steel, 304/316 Stainless Steel, Monel, Hastelloy, F11, F5, F22 AlloySteel. Others on request.

FLOW NOZZLE

7www.flowmaster.com.br

Page 8: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

Flow Measurement

Due to its simplicity in installation, lowmanufacturing cost and high durability, the OrificePlate is more favorable than other types of flowmeters. For each process situation, F. Master has thesolutions in flow measurement through OrificePlates with the types: Concentric, Eccentric,Segmental, Quadrant Edge, Conical Entrance.According to ISO 5167 and AGA-3 Standards.

Materials: 304/316 Stainless Steel, Duplex, Super Duplex, Hastelloy, Monel. Otherson request.

ORIFICE PLATE

8 www.flowmaster.com.br

The OrificeFlow has advantages over other primaryelements, since only common flanges are used in theinstallation, not the more expensive orifice flanges.The fittings are also eliminated, leaving the installationcompact and reducing potential leakage points. F.Master's OrificeFlow has a 3 Way Manifold Valve builtinto the meter and can be connected to any type ofdifferential pressure transmitter. Materials: 304/316 Stainless Steel, Duplex, Super Duplex,Hastelloy, Monel. Others on request.

ORIFICEFLOW

Page 9: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

Flow Measurement

9www.flowmaster.com.br

The OrificeFlow - Conditioner is designed to be acompact solution compared to traditional orificeplates, it conditions the passage of the fluid at thesame instant it generates the differential pressurethrough its 4 holes. This flow meter reduces pipe straight run, requiringonly two pipe diameters (2D) upstream anddownstream for installation in tight areas, while thetraditional orifice plate needs around 20D upstreamand 5D downstream.

ORIFICEFLOW - CONDITIONER

Materials: 304/316 Stainless Steel, Duplex, Super Duplex, Hastelloy, Monel. Otherson request.

The Integral Orifice is a flow meter for pipeswith diameters below 2", and can be setdirectly with a secondary element (transmitter).

INTEGRAL ORIFICE

Materials: Carbon Steel, 304/316 Stainless Steel, Duplex, Super Duplex. Others onrequest.

It is generally used for flowmeasurement of clean fluids (liquid, gas)in laboratories and industrial pilot plants.According to ASME MFC 14M Standard.

Page 10: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

Flow Measurement

METER RUNThe Meter Run (calibrated Meter Tube) isused for flow measurements where higheraccuracy is required for pipes smaller than 2". Used for clean fluids (liquid, gas)measurements.According to ASME MFC 14M Standard.

Materials: Carbon Steel, 304/316 Stainless Steel, Duplex, Super Duplex. Others onrequest.

10 www.flowmaster.com.br

It consists of an Orifice Plate with union flange.Used in the piping system to measure the flowof liquids and gases through the Orifice Plate.It incorporates the 1/2" NPT or SW pressuretaps into the flanges, as requested by thecustomer.

ORIFICE FLANGE ASSEMBLY

This flow meter can be applied to a wide variety of measurements, involving mostgases and liquids, including fluids with solids in suspension, as well as viscous fluidsover a wide range of temperature and pressure. It can be applied in any tube size. According to ISO 5167 and AGA-3 Standards. Materials: Carbon Steel, 304/316 Stainless Steel, Duplex, Super Duplex. Others onrequest.

Page 11: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

Flow Measurement

It is the most practical solution to place a flowmeasurement point on an existing line,avoiding the placement of orifice flanges or inthe case of lines with special alloys, replacingthese flanges with conventional flanges,reducing the installation cost.

ORIFICE ASSEMBLY

Can be manufactured with flange taps, corner taps or piezometric.Its manufacturing is performed according to the ISO Standard, thus giving a greaterreliability to its measurement. Materials: Carbon Steel, 304/316 Stainless Steel, Duplex, Super Duplex. Others onrequest.

11www.flowmaster.com.br

The Parshall Gutter is a device traditionallyused for flow measurement in open channels,widely used in water treatment plants. Materials: Fiberglass, Carbon Steel, 304/316Stainless Steel. Others on request.

PARSHALL GUTTER

Designed to meet the needs of manufacturersof ultrasonic meters.All spools are manufactured with the qualityrequired for this type of meter and testedaccording to customer needs.

ULTRASONIC SPOOL

Materials: Carbon Steel, 304/316 Stainless Steel, Duplex, Super Duplex. Others onrequest.

Page 12: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

F. Master supplies Measuring Stations and customized Measuring Systems fordifferent applications.

MEASURING STATION

Meter Tubes are required to meet ISO5167 or AGA-3 standards for theinstallation of flow measurementelements, ensuring standardized levelsof uncertainty. According to ASME B16.5, ASMEB31.4, ASME B31.8, N-0076Standards.

METER TUBE

Materials: Carbon Steel, 304/316 Stainless Steel, Duplex, Super Duplex. Others onrequest.

Aplications: Custody Transfer Measurement | Allocations | Onshore | Offshore

Flow Measurement Systems

12 www.flowmaster.com.br

Page 13: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

Mounted upstream of the meter to reduce thelength of the measuring tube, conditioningthe flow and avoiding turbulence caused byvalves and fittings.

FLOW CONDITIONERS

The Zanker Holder is a device used to facilitatethe installation of the conditioner in the pipe,replacing flange assemblies, eliminating joints,and facilitating maintenance and cleaning. Designed and produced to meet ISO 5167, AGA-3, ASME B16.5, ASME B16.34 and MSSSP-55 Standards. Materials: Carbon Steel, 304/316 Stainless Steel,Hastelloy, Monel. Others on request.

ZANKER HOLDER

Flow conditioners are dimensioned andconstructed according to InternationalStandards AGA-3 and ISO 5167.

Accessories

STRAIGHTENING VANES

The Zanker Flow Conditioner is mountedbetween flanges upstream of the meter toreduce the length of the measuring tube,conditioning the flow and avoiding turbulencecaused by valves and fittings. Materials: Carbon Steel, 304/316 StainlessSteel. Others on request.

ZANKER FLOW CONDITIONER

13www.flowmaster.com.br

Page 14: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

Accessories

The Air Distributor is used in pneumatic lines todistribute compressed air to some instruments.All outlets have needle valves or according tocustomer specifications.

AIR DISTRIBUTOR

Materials: Carbon Steel, 304/316 Stainless Steel,Alloy Steel. Others on request.

Seal Pots are used in the flowmeasurement of high-density and corrosivemedia to protect differential pressuremeasuring instruments from these media.

SEAL POT / CONDENSATE POT

Condensate Pots are indispensable for the measurement of steam. They maintain aconstant condensate head within the measuring line above the differential pressuretransmitter in order to ensure an accurate measurement.According to ASME standard.

Materials: Carbon Steel, 304/316 Stainless Steel, Hastelloy, Monel. Others onrequest.

14 www.flowmaster.com.br

Page 15: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

Accessories

With its "8" shaped design, having a closedportion and another one with a hole, Figure 8 isused to block the flow of a line, usually fortesting and maintenance.According to ASME B16.48 Standard. Materials: Carbon Steel, 304/316 StainlessSteel, Alloy Steel. Others on request.

FIGURE 8

Materials: 304/316 Stainless Steel, Duplex, Super Duplex, Hastelloy, Monel. Otherson request.

The Restriction Orifice is used where pressure lossin the process is required, decreasing pressure inbranches of a main line.It can also be used in the main line to reduce theprocess pressure permanently. The design principle of the Restriction Orifice isbased on the design of the Orifice Plate, being themethod of calculating permanent loss of charge tobe generated and the standardized dischargecoefficients.

RESTRICTION ORIFICE

15www.flowmaster.com.br

Page 16: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

The RTJ Plate Holder is used formounting Orifice Plates and RestrictionOrifices between RTJ flanges inpressure classes from 150 to 2,500 lbs.According to ASME B16.20 and ASMEB16.5 Standards.

RTJ PLATE HOLDER

Accessories

Materials: Carbon Steel, 304/316Stainless Steel, Alloy Steel. Others onrequest.

The Spacer Ring has the function of generating asmall extension of a line for possible mechanicalassembly needs in the line without the need ofboiler services and welding in the field.According to ASME B16.48 Standard. Materials: Carbon Steel, 304/316 Stainless Steel,Alloy Steel. Others on request.

SPACER RING

16 www.flowmaster.com.br

Page 17: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

Accessories

SAMPLERS

Gas Samplers are used to collect fluid (gas)samples in the pipeline with ease and safety. Samplers are manufactured by F. Masteraccording to API 14, ISO 10715 Standardsor according to customer specifications.

GAS SAMPLER

Oil Samplers are used to collect fluid (oil)samples in the pipeline and it can also collectthen in several sections of the flow. Materials: Carbon Steel, 304/316 StainlessSteel. Others on request.

OIL SAMPLER

17www.flowmaster.com.br

Page 18: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

The Needle Locking Valve is used in processes that requireflow interruption, ensuring safety and operational ease. Materials: Stainless Steel. Others on request.

NEEDLE LOCKING VALVE

Valves

The Manifold Valves manufactured by F. Master are designed to operate inindustrial processes where any model oftransmitter, manometer and other readinginstruments are installed.The manufacture of the needle typesealing system with rotary conical tipprovides a perfect seal, preventing processleakage and locking of the stem near thevalve bonnet. Materials: Stainless Steel. Others onrequest.

MANIFOLD VALVES

5 Way

2 Way

Designed to facilitate interruption, calibration, drainage andrelief in process.This two way model is used in connections ofmanometers, pressure switches and pressure transmitters. Materials: Stainless Steel. Others on request.

2 WAY LOCKING VALVE

3 Way

18 www.flowmaster.com.br

Page 19: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

Fittings

Designed to ensure compatibility withdouble ferrule type connections. The double ferrule system ensures a perfectfit in the tube, providing excellent sealing inlow, medium and high pressure. Materials: 304/316 Stainless Steel. Otherson request Dimensions: O.D. Tubes 1/4" - 3/8 " - 1/2" -3/4"

O.D. FITTINGS

19www.flowmaster.com.br

Page 20: F L O W ME A S U R E ME N T - flowmaster.com.br · f aci l i t i es and i n t he mai n process i ndust ri es of Lat i n A meri ca. W e have provi ded val ves and f l ow met ers t

Phone: +55 (11) 4013-8858Email: [email protected]

Web: www.flowmaster.com.br

367 Rua José Carlos MorenoItu, SP 13313-521 Brazil

F. Master Sistemas de Medição Ltda.March 2019 P

rinte

d in

Bra

zil 0

3/10

/19

The catalog is subject to change without prior consultation or notice.