falb series led area light installation sheet · 2018. 3. 15. · the drilling template to mount...

1
CAUTION: PLEASE FOLLOW THIS INSTRUCTION MANUAL CAREFULLY TO PREVENT ANY INJURIES OR COMPLICATIONS THAT MAY ARISE. WARNING: Before installing or maintaining the luminary, make sure all powers are TURNED OFF. Verify that supply voltage is correct by comparing it with the label information on all fixtures. Make all connections in accordance with the NEC requirements, and make sure all luminaries are properly secured to prevent any wire complications. This luminary is to always be installed with the lens facing down and its not to exceed the maximum ambient temperature rating noted on the specification sheet. FALB Series LED Area Light Installation Sheet Need help? Tech help line: (800) 988-6386 Email: [email protected] Website: www.paclights.com Copyright © 2017 PacLights All Rights Reserved Note: Instructions are subject to change at any time without notice 02-00025-031418-5 AC-ALB-FM2 Flood Mount Includes: FALB185, FALB240, FALB300 DRILLING TEMPLATE WIRING DIAGRAM The LED Driver input cable consists of 3 conductors: ACL (black), ACN (white), and ground (green). These conductors are to be connected to a Power Supply Cable. (For Dimmable Fixtures) The Dimming cable consists of 2 conductors: DIM+ (Blue/ Brown+Gray) DIM- (White/ Blue+ Black) FALB DIM+ (BLUE) DIM- (WHITE) 2. Once the angle brackets are fastened onto the FALB fixture. Using the provided washers and machine screws, fasten the AC-ALB-FM2 brackets to the angle brackets. Do not tighten completely to allow of adjusting. 1. Fasten the two AC-ALB-FM2 angle brackets to the back side of the FALB fixture with the provided socket head machine screws. Install the angles brackets with the back plate towards the inward direction to the fixture. 4. Fasten the AC-ALB-FM2 Flood Mount bracket to the mounting surface using the appropriate mounting bolts. (not included) 3.031” 1.52” 1.52” 1.78” 2.06” R.25” 3.031” R2.03” O.78” 2x O.50” R.25 10.50” 5. Adjust the tilt angle on the FALB to get the light beam pointing towards the desired location. 6. Tighten the socket-head machine screws with an allen wretch to keep the fixture in place. 3. Drill holes on the mounting surface by following the Drilling Template to mount the AC-ALB-FM2 flood mount to the desired height. 7. The FALB power cable must be fed into a Junction Box specific for outdoor applications. Follow the wiring diagram provided to install the FALB to the power cable. All wiring must be done inside the J-box and all cables must be fed through a water-proof connector. All wiring must be installed by a certified electrician and must be compliant to NEC standards.

Upload: others

Post on 04-Feb-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

  • CAUTION: PLEASE FOLLOW THIS INSTRUCTION MANUAL CAREFULLY TOPREVENT ANY INJURIES OR COMPLICATIONS THAT MAY ARISE.WARNING: Before installing or maintaining the luminary, make sure all powers areTURNED OFF.Verify that supply voltage is correct by comparing it with the label information on allfixtures.Make all connections in accordance with the NEC requirements, and make sure allluminaries are properly secured to prevent any wire complications. This luminary isto always be installed with the lens facing down and its not to exceed the maximumambient temperature rating noted on the specification sheet.

    FALB Series LED Area Light Installation Sheet

    Need help? Tech help line: (800) 988-6386 Email: [email protected] Website: www.paclights.com

    Copyright © 2017 PacLights All Rights Reserved

    Note: Instructions are subject to change at any time without notice 02-00025-031418-5

    AC-ALB-FM2 Flood MountIncludes: FALB185, FALB240, FALB300

    DRILLING TEMPLATE

    WIRING DIAGRAM

    The LED Driver input cable consists of 3conductors: ACL (black), ACN (white),and ground (green). These conductorsare to be connected to a Power SupplyCable.

    (For Dimmable Fixtures) The Dimmingcable consists of 2 conductors:DIM+ (Blue/ Brown+Gray)DIM- (White/ Blue+ Black)

    FALB

    DIM+ (BLUE)

    DIM- (WHITE)

    2. Once the anglebrackets arefastened onto theFALB fixture. Usingthe providedwashers andmachine screws,fasten theAC-ALB-FM2brackets to theangle brackets.Do not tightencompletely toallow of adjusting.

    6a. If the Power Supply Cable is coming from the wall, thePower Supply cord will most likely be running through the1 in. hole on the center of the bracket. For this case, youcan connect the FALB to the Power Supply without using aJunction Box only if used with a weather proof connector.Same type of connector is needed if the customer will alsobe using the dimming cables. (not shown)

    1. Fasten the two AC-ALB-FM2 angle brackets to the back side of the FALBfixture with the provided socket head machine screws. Install the anglesbrackets with the back plate towards the inward direction to the fixture.

    4. Fasten the AC-ALB-FM2 Flood Mountbracket to the mounting surface using theappropriate mounting bolts. (not included)

    5

    DRILLING TEMPLATE

    3.031”

    3.031” 3.031” 3.031” 3.031”

    3.031”

    3.031” 3.031”

    3.031”

    1.52” 1.52” 1.78”2.06”

    R.25”

    3.031”

    R2.03”O.78”2x O.50”R.25

    10.50”

    5. Adjust the tilt angle on the FALB to get the lightbeam pointing towards the desired location.

    6. Tighten the socket-head machine screws withan allen wretch to keep the fixture in place.

    3. Drill holes on the mounting surface by followingthe Drilling Template to mount the AC-ALB-FM2flood mount to the desired height.

    7. The FALB power cable must be fed into a Junction Box specificfor outdoor applications. Follow the wiring diagram provided toinstall the FALB to the power cable. All wiring must be done insidethe J-box and all cables must be fed through a water-proofconnector. All wiring must be installed by a certified electricianand must be compliant to NEC standards.