fault counter ground rod driver bit

14
STAPLE PULLER Cat. No. 6400 Permits easy removal of staples installed over round wire moulding without damage. STAPLE STICK Cat. No. 574 The Staple Stick holds 12 staples and as a staple holder, it allows for proper alignment over ground wire and prevents staples from flying if not hit square with first hammer blow. Two Staple Sticks will hold enough staples for a standard distribution pole. 1/2” hole allows attachment to belt hook. Slot dimmensions: 1/8” x 7/8” Overall length: 14-1/4” Cat. No. 574L Holds 10 1” wide staples Staples sold separately-see page 150 130 HI-LINE UTILITY SUPPLY CO. Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com GROUNDING GROUND ROD DRIVER Cat. No. GP This manual Ground Rod Driver will drive up to 5/8" rods fast and safely. An eight foot rod can be driven below ground level with ease. The side handles combined with our INTERNAL HAMMER keep hands and fingers away from any impact areas. GROUND ROD DRIVER BIT Cat. No. DB58C Our exclusive "INTEGRITY CHAMBER" eliminates rod tip damage allowing couplers to be used when stacking additional lengths. This bit has a 3/4" hex shank and is sized for driving 5/8" rod with the Bosch 11-305 or hammers using the same shank size. FAULT COUNTER The Chance Type FC Fault Counter can aid in locating intermittent fault transients. Such faults can be common on the overhead circuit. Intermittent faults such as those caused by a contaminated or broken insulator can be difficult to locate because they are usually cleared by circuit interruption. It will display up to 10 individual faults and is easily reset using the Reset Tool attached to a Grip-All clampstick. Cable size: .25 - 1.0 in. dia. Cat. No. Trip Current Cat. No. Trip Current FC0100 100 amps FC0600 600 amps FC0200 200 amps FC0800 800 amps FC0300 300 amps FC1000 1000 amps FC0400 450 amps FCRT Reset Tool ROLLING GROUND Cat. No. 0902 Weight of 23 lbs., roller diameter is 7”, roller width is 3.66”.

Upload: others

Post on 19-Feb-2022

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FAULT COUNTER GROUND ROD DRIVER BIT

STAPLE PULLER

Cat. No. 6400Permits easy removal

of staples installed over round wiremoulding without damage.

STAPLE STICKCat. No. 574

The Staple Stick holds12 staples and as a stapleholder, it allows for properalignment over ground wireand prevents staples from

flying if nothit squarewith first hammer blow. Two StapleSticks will hold enough staples for astandard distribution pole. 1/2” holeallows attachment to belt hook.

Slot dimmensions: 1/8” x 7/8”Overall length: 14-1/4”

Cat. No. 574LHolds 10 1” wide staples

Staples sold separately-see page 150

130HI-LINE UTILITY SUPPLY CO.Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com

GROUNDING

GROUND RODDRIVERCat. No. GP

This manual Ground Rod Driverwill drive up to 5/8" rods fast andsafely. An eight foot rod can bedriven below ground level withease. The side handles combinedwith our INTERNAL HAMMERkeep hands and fingers away fromany impact areas.

GROUND ROD DRIVER BITCat. No. DB58C

Our exclusive "INTEGRITY CHAMBER"eliminates rod tip damage allowing couplers to be usedwhen stacking additional lengths. This bit has a 3/4"hex shank and is sized for driving 5/8" rod with theBosch 11-305 or hammers using the same shank size.

FAULT COUNTERThe Chance Type FC Fault

Counter can aid in locating intermittent fault transients. Such faults can be common on the overhead circuit. Intermittent faults such as those caused by a contaminated or broken insulator can be difficult to locate because they are usually cleared by circuit interruption. It will display up to 10 individual faults and is easily reset using the Reset Tool attached to a Grip-All clampstick.Cable size: .25 - 1.0 in. dia.

Cat. No. Trip Current Cat. No. Trip Current

FC0100 100 amps FC0600 600 amps

FC0200 200 amps FC0800 800 amps

FC0300 300 amps FC1000 1000 amps

FC0400 450 amps FCRT Reset Tool

ROLLING GROUNDCat. No. 0902

Weight of 23 lbs., roller diameter is 7”, rollerwidth is 3.66”.

Page 2: FAULT COUNTER GROUND ROD DRIVER BIT

DRIVE POINTS F/GROUND RODCatalog Number DP58C

Attach this hardened, sharppoint to your rod tips and makedriving easier while reducingdrag along rod length.

5/8” THREADEDGROUND RODCOUPLER

Cat. No. CTC58

GROUND RODCONNECTORCat. No. GC-268

This connector is used toconnect #6 - #10 conductor to1/4”- 5/8” ground rod. The 3/8”shearhead bolt (9/16” head) isdesigned for a permanenttamperproof connection.Complies with UL-467 andlisted by ETL.

131HI-LINE UTILITY SUPPLY CO.Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com

GROUNDING

TRAVELING GROUNDThis equipment was

designed to protectlinemen against fatalinjuries or severeburns during allstringing operations.It's design provides acontinuous ground andguards againstaccidental energizingof moving conductors.

TEMPORARY TRUCK GROUNDCatalog Number HL958-TG

The temporary truck grounding tool allows foreasy safe driving of atemporary ground rodand also easyremoval. The exposedend of this tool isinternally threaded, sothat a standard 5/8"sectional rod can bethreaded into theshaft. The ground rod then can be driven to thedesired depth and a suitable clamp attached to therod. Ground Rod Driver Only - Cable not included.

Cat. No. Conductor Range Weight

JT3TA .0625" - 1" 3.5 lbs.

JT77TA .250" - 1.625" 4.75 lbs.

ITEMS ON THIS PAGE CAN BE SIZED OR ADAPTED TO OTHER

SPECIFIC APPLICATIONS.

THREADED GROUND RODCat. No. C635860 5/8” x 6’ Copper

5/8” DRIVE HEADCat. No. CTDH58 ThreadedCat. No. CDH58 Non-Threaded

TEMPORARYGROUND RODCat. No. G3370

This reusable, copper cladScrew Ground Rod provides atemporary ground where a systemground is not available. Wheninstalled, the 6' spiraled groundrod develops less resistance thanstraight ground rods. However,actual effectiveness depends uponsoil properties.

Convenient for truck groundingapplications.

Page 3: FAULT COUNTER GROUND ROD DRIVER BIT

132HI-LINE UTILITY SUPPLY CO.Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com

GROUNDING

GROUNDING EQUIPMENT

CHOOSE COMPLETE ASSEMBLIES OR INDIVIDUAL COMPONENTS FROM THE FOLLOWING PAGES

1. Clamps:Clamping Size Range, Current Capacity, Application Clearance, and Terminal Connection Type (threaded or pressure type)

2. Cable:Length, Jacket Type, and Adequate Capacity to Withstand Maximum Potential System Fault Current Magnitude and Full Time Duration

3. Ferrules:Aluminum or Copper, Fit Cable Size, and Connection Type to Match Clamp (threaded or pressure type) Note: Either aluminum or copper ferrules may be used with copper cable.

4. Support Stud (replaces strap on strain relief clamp)This option recommended on only one clamp to help control lifting the set to the first clamp attachment point.

5. Shrink TubingThis option recommended for stress relief and inspection of cable strands between ferrule and jacket.

HOW TO ORDER GROUND SETS

NOTE: DO NOT USE WELDING CABLE ON GROUND SETS -Responsibility for selection of the proper product or application rests

solely with the purchaser

GROUNDING SETS - COMPLETE ASSEMBLIESThese pre-assembled GROUND sets are offered in a range of sizes and lengths. Clear, flexible grounding

cable from page 134 is used. Shrouded, threaded copper ferrules with shrink tubing are used on all sets

offering excellent connection and strain relief properties.

COMPLETE CLEAR GROUNDING SET ASSEMBLIES W/ T600-0658 C-CLAMP - GRIP RANGE OF .162" - 2"

Cable Size

Cable Length 1/0 4/0

3' HLGA10C-03 HLGA40C-03

6' HLGA10C-06 HLGA40C-06

8' HLGA10C-08 HLGA40C-08

10' HLGA10C-10 HLGA40C-10

15' HLGA10C-15 HLGA40C-15

30' HLGA10C-30 HLGA40C-30

45' HLGA10C-45 HLGA40C-45

50' HLGA10C-50 HLGA40C-50

75' HLGA10C-75 HLGA40C-75

COMPLETE 3-LEG CLEAR GROUND SET ASSEMBLIESW/ T600-0466 C-CLAMP - RANGE OF .162" - .814"

3' HLGC10C-03

6' HLGC10C-06

8' HLGC10C-08

10' HLGC10C-10

12' HLGC10C-12

3-LEG SETS FOR USE IN VAULTS, ESS, LOW PROFILE SWITCH GEAR,SECTIONALIZERS, WALL MOUNTED METAL SWITCHES, FUSE CABINETS OTHER CONFIGURATIONS ALSO AVAILABLE

Page 4: FAULT COUNTER GROUND ROD DRIVER BIT

133HI-LINE UTILITY SUPPLY CO.Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com

GROUNDING

GROUNDED PARKING BUSHING SETFor Single-Phase or Three-Phase Switches & Transformers

This set includes a loadbreakbushing and T600-0466 bronzeground clamp connected by a 4foot, 1/0 clear jacket copperground cable and ferrules.

UNDERGROUND DISTRIBUTION GROUNDING SETS

GROUNDING ELBOW SETS

For Single-Phase or Three-Phase Switches & Transformers

Each assembled set includes an orange-jacketed elbow for thevoltage-class indicated below, 6 feet of 1/0 clear jacket coppergrounding cable, ferrules and T600-0466 bronze ground clamp.

Fault current rating foreach set: 10,000 amps for10 cycles.

THREE-PHASE GROUNDING ELBOW SETSFOR SWITCHES & TRANSFORMERS

Each of these sets consists of a three-way terminal blockassembly, three 6 foot lengths of 1/0 clear jacket copper groundcable, ferrules, one T600-0466 bronze ground clamp and threeorange elbows.

Fault current rating foreach set: 10,000 amps for10 cycles

CONCENTRIC GROUNDING SETCat. No. HLGI20C-08

This 8’ concentric grounding set includes 2-7603C spring loadedclamps, ferrules and 2/0 clear jacket grounding cable. Grip rangeof clamps is 3/4”- 2”

Cat. No. Application Wgt.

C600-0729 15kV 4 lbs.

T600-2131* 25kV/35kV 6 lbs.

C600-1927** 35kV 8 lbs.

Cat. No. Application Wgt.

C600-3102 15kV 14.5 lbs.

C600-3103* 25kV/35kV 15 lbs.

Cat. No. Description Wgt.

T600-3091 1 leg - 15kV 8 lbs.

T600-3091C 3 leg - 15kV 20 lbs.

T600-3092 1 leg - 25kV 9 lbs.

T600-3091

T600-3091C

*For 25kV or small 35kV Elastimold interface**Cooper(RTE) large interface

*For small 25kV or smaller 35kV Elastimold interfaceNote: Large 35kV Cooper elbow ground sets available on request

Page 5: FAULT COUNTER GROUND ROD DRIVER BIT

134HI-LINE UTILITY SUPPLY CO.Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com

GROUNDING

SHRINK TUBINGCat. No. P600-1593 5” Long PieceCat. No. P600-1594 8” Long Piece

Clear heat shrink tubes provide stress relief,corrosion protection, and visual inspection.

SUPPORT STUDSCat. No. G3627

These support studscan be installed in place of the restraining strapimmediately below the pressure terminal. The studserves as a parking stand for a second clamp.

COPPER GROUNDING CABLE

This copper grounding cable has a transparentthermoplastic jacket allowing for constant, fulllength inspection of cable strands unlike solidjackets which can conceal strand damage andoxidation. This Jacket is smooth, abrasion, andweather & oil resistant and remains flexible from -29°C to 90°C. This material passes a -40°C cold binand meets Type II requirements of ASTM F 855.AWG size is marked on jacket. Black and Yellowjackets are T-prene rubber compound and can beused to -20

o

F.

UNSHROUDED FERRULES

CLEAR YELLOW Flexible Jacket Copper Cable

Cat. No. Cat. No. AWG Prox. O.D. Prox. Wgt.

S6449 S6116 2 .53" 300 lb/cft

S7568 S6117 1/0 .64" 475 lb/cft

S6450 S6118 2/0 .70" 565 lb/cft

S6451 S6119 4/0 .84" 856 lb/cft

Black Jacket Cable Also Available

Threaded Type Plain Pressure Type

Unshrouded Ferrules Unshrouded Ferrules

Cable Alum Copper Alum Copper

AWG Cat. No. Cat. No. Cat. No. Cat. No.

#2 C600-2602 C600-2606 C600-2610 C600-2614

1/0 C600-2603 C600-2607 C600-2611 C600-2615

2/0 C600-2604 C600-2608 C600-2612 C600-2616

4/0 C600-2605 C600-2609 C600-2613 C600-2617

Use either Aluminum or Copper ferrules with copper cableTo Crimp Unshrouded Ferrules Above,Use Die Number U165 on Cppr & Alum Ferrules up to 2/0 Use Die Number U166 on 4/0 Copper FerrulesUse Die Number U249 on 4/0 Aluminum Ferrules

Threaded Type Plain Pressure Type

Shrouded Ferrules Shrouded Ferrules

Cable Alum Copper Alum Copper

AWG Cat. No. Cat. No. Cat. No. Cat. No.

#2 C600-2618 C600-2622 C600-2626 C600-2630

1/0 C600-2619 C600-2623 C600-2627 C600-2631

2/0 C600-2620 C600-2624 C600-2628 C600-2632

4/0 C600-2621 C600-2625 C600-2629 C600-2633

Use either Aluminum or Copper ferrules with copper cableTo Crimp Shrouded Ferrules Above,Use Die Number U165 & U166 on #2 Cppr & Alum FerrulesUse Die Number U165 & U168 on 1/0 Cppr & Alum FerrulesUse Die Number U165 & U-L on 2/0 Cppr & Alum FerrulesUse Die Number U166 & U-L on 4/0 Cppr FerrulesUse Die Number U249 & U-L on 4/0 Alum Ferrules

2" C-TYPE GROUNDING CLAMPCat. No. T600-0658

This smooth jaw,aluminum body, c-clamp isused on our standard, stocksets. It incorporates a bronze,acme thread eyescrew anddrilled terminal hole for usewith threaded ferrules.

Continuous Current:400 Amps

Fault Current:15 Cycles - 43,000 Amps30 Cycles - 30,000 Amps

Main Line Clamp Range:#6 Solid Copper - 2” O.D. Bus

Jumper Range:#2 Ground Cable - 4/0 Ground Cable

ALWAYS.... USE A WIRE BRUSH ON BARE CONDUCTOR

TO REMOVE OXIDES AND CONTAMINANTS BEFORE

ATTACHING GROUNDS, JUMPERS,

TAPS, SPLICES OR CONNECTORS - SEE PAGE 140

SHROUDED FERRULES

Page 6: FAULT COUNTER GROUND ROD DRIVER BIT

CLUSTER BARCat. No. T600-1549

Compact 5"aluminum-alloy bar(5/8" dia) accepts C-typeor duckbill clamps forphase-to-phasegrounding technique.Adjustable wheel binderand 36" chain for wood pole attachment.

Order T600-1737 hook style bar for attachment tosteel tower.

MULTI USE C-TYPE CLAMPSWIDE RANGE .16 - 2"

These grips were designed for a wide range ofconductor sizes as well as other cable, bus, andtower applications. This approach is intended toreduce inventory and eliminate the overlappingranges and applications of other model C-typeclamps.

All have aluminum body with bronze eye screw.Available with choice of smooth or serrated jawsand pressure type or drilled terminal for threadedferrules.

Drilled Terminal, For Threaded Ferrules

Cat. No. C600-2255 w/ Smooth Jaws

Cat. No. C600-2256 w/ Serrated Jaws

Pressure Type TerminalFor Plain Ferrules

Cat. No. C600-2281 w/ Smooth Jaws

Cat. No. C600-2282 w/ Serrated Jaws

Mechanical Ratings

Recommended Torque (in.-lb.) 250

Main Line Range - Max. 2" O.D. Bus

Main Line Range - Min. #6 Sol. Cu. (.162")

Jumper Range - Max. 4/0 Grd. Cable w/ Ferrule

Jumper Range - Min. #2 Grd. Cable w/ Ferrule

Weight, Each 2 lb.

ASTM Designation Type 1, Class A, Grade 5

Electrical Ratings

Continuous Current (AMPS) 400

Fault Current - 15 Cycles (AMPS) 43,000

Fault Current - 30 Cycles (AMPS) 30,000

135HI-LINE UTILITY SUPPLY CO.Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com

GROUNDING

INSULATED HANGERCat. No. S1600-7

The Insulated hanger serves as aconvenient parking stand whilelinemen are installing Jumper orGrounding Clamps on lines up to34.5kV. The bronze double studfitting is 1/2” x 3 1/2” on each side.

GROUND SET BAGSCat. No. HL5993

4-WAY GROUND CONNECTORCat. No. G-4754-1

3-way and

Threaded Connectors

Also Available

Page 7: FAULT COUNTER GROUND ROD DRIVER BIT

136HI-LINE UTILITY SUPPLY CO.Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com

GROUNDING

Catalog Number T600-0466 C600-1754 C600-1743 G3605-1 G3367-2

Electrical Ratings

Continuous current (AMPS) 200 350 400 400 400

Fault Current-15 Cycles (AMPS) 21,500 28,000 43,000 43,000 43,000

Fault Current-30 Cycles (AMPS) 15,000 20,000 30,000 30,000 30,000

Mechanical Ratings

Recommended Torque (in.-lb.) 200 250 250 250 250

477 kcmil 750 kcmil 1000 kcmil 2" O.D. 2.5" O.D.

Main Line Range - Max ACSR Str. Cu. Cu. Bus Bus

(.814) 636 kcmil 1590 kcmil

ACSR (.998) ACSR (1.50)

Main Line Range - Min. #6 Sol. Cu. #8 Sol. Cu. #6 Sol. Cu. #6 Sol. Cu. #4 Str. Cu.

(.162) (.128 (.162) (.162) (.232)

Jumper Range - Max 1/0 Grd. Cable 2/0 Grd. Cable 4/0 Grd. Cable 4/0 Grd. Cable 4/0 Grd. Cable

w/ Thread Ferrule w/ Thread Ferrule w/ Thread Ferrule w/ Plain Ferrule w/ Plain Ferrule

Jumper Range - Min #2 Grd. Cable #2 Grd. Cable #2 Grd. Cable #2 Grd. Cable #2 Grd. Cable

w/ Thread Ferrule w/ Thread Ferrule w/ Thread Ferrule w/ Plain Ferrule w/ Plain Ferrule

Weight, Each 1.5 lb. 1 lb. 1.5 lb. 1.75 lb. 2.38 lb.

Type I Type I Type I Type 1 Type I

ASTM Designation Class A Class A Class A Class A Class A

Grade 2 Grade 3 Grade 5 Grade 5 Grade 5

C-TYPE GROUNDING CLAMPS

T600-0466

.162 - .814

Bronze Body

Smooth Jaws

Drilled Terminal for

Threaded Ferrule

C600-1754

.128 - .998

Aluminum Body

Smooth Jaws

Threaded Terminal

C600-1743

.162 - 1.5

Aluminum Body

Smooth Jaws

Threaded Terminal

G3605-1

.162 - 2

Aluminum Body

Smooth Jaws

Pressure Type

Terminal

G3367-2

.232 - 2.5

Aluminum Body

Smooth Jaws

Pressure Type

Terminal

ALWAYS.... USE A WIRE BRUSH ON BARE CONDUCTOR TO

REMOVE OXIDES AND CONTAMINANTS BEFORE ATTACHING

GROUNDS, JUMPERS, TAPS, SPLICES OR CONNECTORS

Page 8: FAULT COUNTER GROUND ROD DRIVER BIT

137

G3622-1

.162 - 1.162

Aluminum Body

Smooth Jaws

Pressure Type

Terminal

SNAP ON CLAMPS

G1810-2

.162 - .574

Aluminum Body

Smooth Jaws

Pressure Type

Terminal

C600-1734

.162 - 1.162

Aluminum Body

Smooth Jaws

Threaded Terminal

C600-0434

.162 - 1.506

Aluminum Body

Serrated Jaws

Pressure Type

Terminal

See "Meters" Section In This Catalog For

GROUND SET TESTERALWAYS.... USE A WIRE BRUSH ON BARE CONDUCTOR TO

REMOVE OXIDES AND CONTAMINANTS BEFORE

ATTACHING GROUNDS, JUMPERS,

TAPS, SPLICES OR CONNECTORS - SEE PAGE 140

C600-22311/8”- 1-1/2”Bronze Body

Serrated Jaws

Drilled Terminal

No Threads

C600-22321/8”- 1-1/2”Bronze Body

Serrated Jaws

Drilled Terminal

No Threads

Catalog Number G1810-2 G3622-1 C600-1734 C600-0434 C600-2231 C600-2232

Electrical Ratings

Continuous current (AMPS) 300 400 400 400 400 400

Fault Current-15 Cycles (AMPS) 28,000 36,000 36,000 43,000 43,000 43,000

Fault Current-30 Cycles (AMPS) 20,000 25,000 25,000 30,000 30,000 30,000

Mechanical Ratings

Recommended Torque (in.-lb.) 200 250 250 250 250 250

Main Line Range - Max 250 kcmil Str 566 kcmil 566 kcmil 950 kcmil 1-1/2” Angles 1-1/2” Angles

Cu. Cu. Cu. Cu.

4/0 ACSR 900 kcmil ACSR 900 kcmil 1510 kcmil 1-1/2” Flat 1-1/2” Flat

(.574) (1.162) ACSR (1.162) ACSR (1.506)

Main Line Range - Min. #6 Sol. Cu. #6 Sol. Cu. #6 Sol. Cu. #6 Sol. Cu. 1/8” 1/8”

(.162) (.162) (.162) (.162)

Jumper Range - Max 2/0 Grd. Cable 4/0 Grd. Cable 4/0 Grd. Cable 4/0 Grd. Cable 4/0 Grd. Cable 4/0 Grd. Cable

w/ Plain Ferrule w/ Plain Ferrule w/ Thread Ferrule w/ Plain Ferrule w/ Thread Ferrule w/ Thread Ferrule

Jumper Range - Min #2 Grd. Cable #2 Grd. Cable #2 Grd. Cable #2 Grd. Cable #2 Grd. Cable #2 Grd. Cable

w/ Plain Ferrule w/ Plain Ferrulew/ Thread Ferrule w/ Plain Ferrule w/ Thread Ferrule w/ Thread Ferrule

Weight, Each 1.5 lb. 1.5 lb. 1.5 lb. 1.5 lb. 2 lb. 2 lb.

ASTM Designation Type I Type I Type I Type I Type I Type I

Class A Class A Class A Class B Class B Class B

Grade 3 Grade 4 Grade 4 Grade 5 Grade 5 Grade 5

HI-LINE UTILITY SUPPLY CO.Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com

GROUNDING

Page 9: FAULT COUNTER GROUND ROD DRIVER BIT

138HI-LINE UTILITY SUPPLY CO.Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com

GROUNDING

TRUCK GROUNDING SYSTEM

For truck grounding system and restricted spaceapplications, this compact clamp design delivers ahigh current rating usually associated with onlylarge clamps. Ball Studs permanently mount ontruck body w/ 1/2-13 x 2" thread, nut & washer.Two clamp styles and two ball stud lengths adapt tomany applications. Ball Stud Cover protects studwhen not in use.

Fault current rating: 43,000 Amps - 15 cycles30,000 Amps - 30 cycles

ASTM Designation: Type I, Class A, Grade 5with ferrules shown on previous page.

C600-2300

w/ Pressure

Terminal

C600-2100

w/ Drilled

Terminal

C600-2101

w/ Tapped

Terminal

C406-0416 Rubber Stud Cover

C600-2102 Ball Stud

T600-2364 Long Ball Stud 3" Shank

EQUI-MATThe Personal Protective Ground Grid...Equi-Mat provides an

easy way to help establishan equipotential zone for aline worker to stand onduring various energizedand de-energized workpractices. It is portableand simple to use,maintain and store.Multiple mats can beconnected to form larger work grids.

Properly applied,the Equi-Mataccomplishescompliance withOSHA 1910.269.

Cat. No. Description

C600-2989 58" x 58" Equi-Mat Set

C600-2990 58" x 120" Equi-Mat Set

C600-2991 120" x 120" Equi-Mat Set

SETS INCLUDE GROUND GRID, LONG BALL STUD, 6'GROUND SET AND STORAGE BAG.

“Equipotential Zone”Temporary protective grounds SHALL be placed

at such locations and arranged in such a manneras to prevent each employee from being exposed to

hazardous differences in electrical potential.

BUCKET EQUI-MAT

Cat. No. HLGM22-22This 22” x 22”model applies the same properties

as the Equi-Mat shown to the left but sized for use ina utility bucket. An 8’ ground cable is supplied forattachment to the boom and a 100’ ground cable issupplied for attachment to ground. Other sizes andconfigurations are available upon request. Minimumorder quantities may apply.

Page 10: FAULT COUNTER GROUND ROD DRIVER BIT

BUS-BAR GROUND CLAMP

Cat. No. 12282This aluminum alloy, smooth jaw

clamp is designed for up to 6.625”dia bus.

Fault Current: 15 cycles - 54,000 Amps30 cycles - 39,000 AmpsJumper Range: 1/0 - 4/0 cable w/ plain ferrules.

SPIKING TOOL

Cat. No. 1715EPPThis hydraulic

ground spike is usedfor grounding anddraining a cableafter it has beende-energized andbefore contact ismade by hand. Eachassembly has a 30' insulated hydraulic hose and ahand-operated hydraulic pump. The ground lead is a1/0 x 6' long copper cable with a clamp end forconnection to a local system ground. 1,200 psi; Wgt: 28 lbs.

Cat. No. 1715-66Similar and larger than the model above except

this unit utilizes a blade in place of a spike whichwill make contact with all three conductors of thesector cable. 10,000 psi; Wgt: 85 lbs.

Cat. No. 1712GAThis is a manual version of the 1715 model

shown above. Use with shot gun.

Cat. No. 1712USame as above but with

universal attachment.

GROUNDED INSULATED RATCHET CUTTER

Cat. No. HL8HC-6LThis unique, 8’ fiberglass handled

cutter comes with an attached, 6’- 1/0ground cable and clamp eliminating theneed for a spiking operation.

Cutting Capacity: 1000 MCM Aluminum500 MCM Copper

SPRING LOADEDCONCENTRICGROUNDING CLAMP

Cat. No. 7603CGrip Range: 3/4”-2”Weight: 4 lbs.

ELECTRO-STATIC PRECIPITATOR

GROUNDING TOOL SET

139HI-LINE UTILITY SUPPLY CO.Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com

GROUNDING

1712GA

Cat. No. T600-0891By design, this

tool set provides areliable means ofdraining off staticcharges that remainon collector platesafter electrostatic-precipitator pollution-control equipment is de-energized for servicing.

Epoxiglas(r) handle (42”x1-1/2”) meets OSHAelectrical requirements, gives operator sufficientadded reach needed to make contacts. Contact hookof 98%-conductive Copper is double-bolted tohandle. T-handle Aluminum grounding clamp withserrated flat-face jaw assures proper bonding. Jawsopen to 1-1/2” for attachment to grounded structuralangles, flats or rods. Extra-flexible Coppergrounding cable, 7 ft., with clear jacket fitted withCopper terminal at each end gives high current-carrying capability.

Weight 7 lb./3.2 kg.

Page 11: FAULT COUNTER GROUND ROD DRIVER BIT

140HI-LINE UTILITY SUPPLY CO.Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com

GROUNDING

CONDUCTOR CLEANER

Cat. No. HLCS-17This flexing conductor cleaner

utilizes a poly, “bow” frame to holdits 1-1/2" x 24" strip of emery cloth.

HOT STICK BRUSH

Cat. No. M4455-63

V-brush gives 2-sided cleaningaction. Brushes can be rotated as theywear.

Cat. No. M1899 Box of 10 repl. brushes.

Cat. No. M4455-92

Tube type brush.

CONDUCTOR CLEANING BRUSHCat. No. M4455-93

5" x 1-1/4" dia.tubular brush hasstainless steel bristlesenclosed reducing thechance of damaging rubber gloves.

Catalog Number 4337This 3" x 1-1/4" dia. tubular

brush is used in confined areassuch as between two previouslyinstalled connectors or clamps.

Cat. No. M1889"V" position of brushes gives two-sided cleaning

action. As brushes wear, they can be rotatedso that unused bristles will come incontact withconductor.

Cat. No. 10-178“V” brush with hole in handle for use with shotgun.

SAND SCREENCat. No. NO180

9" x 11," 180 gritwashable andreusable sheets forcleaning conductor .25 sheets per pack

ALWAYS.... USE A WIRE BRUSH ON BARE CONDUCTOR TO

REMOVE OXIDES AND CONTAMINANTS BEFORE ATTACHING

GROUNDS, JUMPERS, TAPS, SPLICES OR CONNECTORS

STORAGE REELCat. No. SR17

Holds 85’ of 2/0 ground cable.

Page 12: FAULT COUNTER GROUND ROD DRIVER BIT

Cat. No. Line Range Max

Voltage Length Min Max Amps

Solid Orange Polyethylene Clamps - Sold in Pairs

5-5/8" 336.4 ACSR .721"

7-1/2" 477 ACSR .883"

8-3/8" 954 ACSR 1.165"

Clear Transparent H.I. Poly-Carb Clamp - Sold Each

10-3/4"

10-3/4" 954 ACSR 36/1

#6 .162Copper

#6 .162Copper

#6 .162Copper

SURE-LOK JUMPER CLAMPSThis clamp features a ratchet type locking mechanism that isguaranteed not to loosen once installed on a line. Pull and turn thelocking knob and it loosens like any traditional clamp.

Standard models (without Sure-Lok feature) are also available.

Sure-Lokclamps are

available witheither Clear

Poly orOrange Salcor

bodies.

141

COMPLETE JUMPER SET ASSEMBLIES W/ 13768 CLEAR CLAMP - GRIP RANGE OF .162" - 1.2"

Cable Size

Cable Length 1/0 2/0 4/0

6' HLJA10-06 HLJA20-06 HLJA40-06

8' HLJA10-08 HLJA20-08 HLJA40-08

10' HLJA10-10 HLJA20-10 HLJA40-10

12' HLJA10-12 HLJA20-12 HLJA40-12

16' HLJA10-16 HLJA20-16 HLJA40-16

22' HLJA10-22 HLJA20-22 HLJA40-22

The orange, SolidPolyethylene Clamp isoffered in three sizes -15kV, 25kV, and 35kV.

The All TransparentClamps provide impactstrength and durabilitywhile allowing inspectionof the cable and connectioncondition. Outer moldedribs afford a good grippingsurface when tighteningconnections.

15KV JUMPER SETS - COMPLETE ASSEMBLIES

These pre-assembled JUMPER sets are offered in a range of sizes and

lengths. Clear jumper clamps are assembled on orange/red jumper cable

from page 142. Tin plated, threaded ferrules with shrink tubing are used

on all sets offering excellent connection and strain relief properties.

HI-LINE UTILITY SUPPLY CO.Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com

JUMPERS, SWITCHING & INSULATORS

Sure-Lok

Cat. No.

Std

Cat. No.Main Line Range

Max Amps

ContinuousRating Wgt

1786 1785 477MCM (.162”- .9”) 400 36Kv P-P 8

2116 2115 954MCM (.162”-1.25”) 400 21Kv P-G 10

SAME AS ABOVE BUT WITH ORANGE SALCOR RUBBER BODIES

2261 2260 477MCM (.162”- .9”) 400 36Kv P-P 10

2271 2270 954MCM (.162”-1.25”) 400 21Kv P-G 11

#6 .162Copper

300

400

400

G4758

15kVG476525kV

G477535kV

13768

15-35kV

400

400

556.5 MCM

477 ACSR

INSULATED JUMPER CLAMPS

STANDARDMODEL

13765

15-25kV#6 .162Copper

Page 13: FAULT COUNTER GROUND ROD DRIVER BIT

142HI-LINE UTILITY SUPPLY CO.Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com

JUMPERS, SWITCHING & INSULATORS

JUMPER CLAMP CONNECTORThese copper

connectorassemblies arenecessary to joincable and clamp together on Jumper Clamps or LoadPickup Tools only. Each comes complete with nutand lock washer.

Adequate Rubber Gloves Must Be Worn When Installing or Removing Jumper Clamps.

15KV JUMPER CABLEW/ EPR Insulation/Jacket

Extremely flexible even at low temperatures, thisorange colored cable features an insulation/jacketcombination resistant to abrasion, oil, heat, moisture,and ozone. Conductors are extra flexible alloy-coated copper stranded rope per ASTM B-189 or B-33. Insulation and conductor screen meet and exceedICEA-NEMA standard S-68-516.

Ampacity ratings are based on 90°C conductortemperature at 40°C ambient.

Approx. Approx.

Cat. Size Ampacity Cable Wgt. Per

No. AWG. Rating Strand O.D. 1000'

S10043 #2 200 259/No.26 .779" 438 lb.

S10044 1/0 260 413/No.24 .863" 598 lb.

S10045 2/0 300 273/No.23 .914" 707 lb.

S10046 4/0 400 437/No.21 1.065" 1047 lb.

ALWAYS.... USE A WIRE BRUSH ON BARE CONDUCTOR

TO REMOVE OXIDES AND CONTAMINANTS

BEFORE ATTACHING GROUNDS, JUMPERS,

TAPS, SPLICES OR CONNECTORS SEE PAGE 140

Catalog Cable Burndy No. of

Number Size Die Crimps

C600-2598 #2

C600-2599 1/0

C600-2600 2/0

C600-2601 4/0 U166

U1652

LOAD PICK UP JUMPER CLAMPfor 15kV, 250 amp loads fits #6 Copperthrough 795 kcmil ACSRCat. No. C403-1631

Contacts are springloaded and are closed by pulling aninsulated lanyard. A fiberglass rod,attached to the end of the lanyard, isused to re-cock the contacts whileremoved from the conductor. Anorange tinted clear Lexan housingpermits easy visual inspection. Thetool can be disassembled for inspectionand maintenance.

The recommended 15kV jumpercables are #2 and 1/0.

Do not use to break loads!

ORDER CABLE AND

CLAMPS SEPARATELY.

Page 14: FAULT COUNTER GROUND ROD DRIVER BIT

LOADBUSTER This Portable Loadbreak Tool is the original, light-weight, easy-to-use

loadbreak tool for use with disconnects, cutouts, and power fuses. It bringsload switching capability through 34.5 kV and 600 amperes nominal, 900amperes maximum to a wide variety of devices on your distribution system.

Loadbuster switching helps keep service interruptions to a minimum.There is no need for complex switching procedures involving opening andreclosing of line and feeder breakers to permit dead switching. Everydisconnect, cutout, and power fuse becomes a sectionalizing point. Liveswitching can be done at the point that minimizes the length of theplanned outage and affects the fewest consumers.

Operation is simple and positive:1) The tool’s anchor is simply hung

on the attachment hook of thedisconnect, cutout or power fuse;

2) Then the pull ring is engagedwith Loadbuster’s pull-ring hook, heldfast by the pull-ring latch.

3) A firm, steady downward pullopens the switching device and tripsthe internal, interrupting circuit.

There is no external arc orcontact burning. Loadbuster can beinstantly reset.

Cat. No. Range Wgt

5300R3 14.4-25kV, 27kVmax-Designed for Overhead 6 Lbs.

5400R3 25kV - 34.5kV, 38kV max-Designed f/ Overhead 7 Lbs

5300R3-E 14.4-25kV, 27kVmax-Designed for Pad Mount Gear 6 Lbs.

5380 Molded case fits both models 4 Lbs.

TAGGING DEVICECat. No. TDFor tagging open disconnectswitches. Orange SalcorLength: 7.25"

Cat. No. 1000Yellow Poly

IN STOCK!

HOT LINE TAP CLAMPCat. No. BC-2/0

This bronze hot line tap clamp isdesigned for use on copperconductor with a diameter range of.128 - .414. (#8 solid - 2/0 Stranded)

O.A. Length: 5”Jaw width:1-1/4”Weight: .7 lbs.

143HI-LINE UTILITY SUPPLY CO.Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com

JUMPERS, SWITCHING & INSULATORS