fc6aserieswebpage editor sales manual plc/fc6a... · fc6aserieswebpage editor sales manual (product...

57
FC6A Series Web Page Editor Sales Manual (Product DescriptionTutorial) Think Automation and beyond WindLDR Ver. 8.20 or later (Automation Organizer Ver. 3.20 or laterIssued by Automation BU Issue No.16-SMBE001-1 Date of Issue May 18 th , 2016

Upload: ngothuy

Post on 29-May-2018

226 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

FC6A Series Web Page Editor

Sales Manual(Product Description・・・・Tutorial)

Think Automation and beyond�

(Product Description Tutorial)

WindLDR Ver. 8.20 or later

(Automation Organizer Ver. 3.20 or later))))

Issued by Automation BU

Issue No.:::: 16-SMBE001-1Date of Issue ::::May 18th, 2016

Page 2: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

Contents

1. System configuration

2. Start Web Page Editor

3. Create user web page

3.1. Components settings

3.1.1 Place components

3.1.2 Import components

3.1.3 Set link to devices

3.2 Components overview and

function example

5. Simulation

6. Download/Access user web page

6.1 Download methods

6.2 Access user web page (by URL)

6.3 Access user web page (by HTTP)

6.4 Set “Base Timer Period”

7. About web page capacity

7.1 Web page capacity

Think Automation and beyond�

function example

3.2.1 Set Link/Event

3.2.2 Set “Goto Screen Button”

3.2.3 About Layer

3.3 Components usage example

3.3.1 Numeric input

3.3.2 Numeric indicator

3.3.2 Alternate switch

4. Save user web page

7.1 Web page capacity

7.2 Capacity confirmation method

8. Help function

Page 3: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

1. System configuration(1)

・・・・Create web page1. Use Web Page Editor to

create web page

2. Download to FC6A

Ethernet

Think Automation and beyond�

Internet Web Browser

・・・・Use WindLDR Web Page Editor to create user web page・・・・Available for creating custom web page and operating/ browsing user webpage which stored in FC6A HMI module.

3. Maintain FC6A

through web page

Page 4: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

1. System configuration(2)

Items Description

WindLDR Ver.8.2.0 or later

System software of FC6A CPU module Ver.1.20 or later

System software of FC6A HMI module Ver.1.20 or later

Operating environment

・・・・IDEC Products

Think Automation and beyond�

*Above-mentioned system software has been included in

Automation Organizer Ver. 3.20 or later.

Page 5: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

1. System configuration(3)

・・・・Web Page Editor((((for development))))

Items Description

Supported browsers (Windows OS) ・Google Chrome 47 or later・Mozilla Firefox 42 or later・Microsoft Internet Explorer 11

・・・・Web page viewer((((for operation))))

Think Automation and beyond�

Items Description

Supported browsers (Windows OS) ・Google Chrome 47 or later・Mozilla Firefox 42 or later・Microsoft Internet Explorer 11

Supported browsers (Android) Google Chrome 47 or later

Supported browsers (iOS) Safari 8 or later

Page 6: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

2. Start Web Page Editor

Start Web Page Editor

Place components

Flow of creating web page using Web Page Editor

Think Automation and beyond�

Save user web page

Download/ Access

user web page

Simulation

Page 7: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

2. Start Web Page Editor

After double-clicking Web Page Editor, Web Page Editor will be

opened by default browser.

Think Automation and beyond�

Page 8: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3. Create a web page

Start Web Page Editor

Place components

Flow of creating web page using Web Page Editor

Think Automation and beyond�

Save user web page

Download/ Access

user web page

Simulation

Page 9: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.1 Components settings

Create user web page

Place components

Import Components

Flow of creating web page using Web Page Editor

Think Automation and beyond�

Import Components

Set link to devices

*This is a basic flow for creating user web page.

Page 10: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.1.1 Place components

Think Automation and beyond�

Drag & Drop a lamp from components list.

Page 11: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.1.2 Import components(1)

Each component is displayed when

deploy the node of Web Page Editor.

Think Automation and beyond�

Also available to import your favorite

images from “Symbol Factory”.

Page 12: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.1.2 Import components(2)

Symbol Factory

Think Automation and beyond�

Selected and stored in Web Page Editor in WindLDR, High-resolution push

button/ pilot lamp which match the resolution of PC and smart devices in

“Symbol Factory”.

Page 13: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.1.2 Import components(3)

Double-click image or

press the “Copy” button

to import components.

Think Automation and beyond�

Imported images are saved as child node

of each component.

to import components.

Page 14: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.1.2 Import components(4)

On Web Page Editor

Think Automation and beyond�

Specify the pass of imported images

to change the image of lamp.

・・・・e.g. Specified part: when lamp is ON

Available to upload images which is

imported by WindLDR in property.

Page 15: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.1.3 Set link to devices

By setting link to devices, FC6A

device is interlocked with

specified action in Web Page

Editor.

・・・・When setting device M0Link::::IDEC:M:M000

Think Automation and beyond�

Link IDEC:M:M000

IO ::::in

*FC6A series device format

IDEC: Type of target device: Target device(.data type)

Please always set data types of devices when data register has been specified

its data type.

・・・・e.g. Data type::::Float, when linking to device address D0IDEC:D:D000.Float

Page 16: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.1.3 Set link to devices(1)

About I/O settings of components

Determine input/ output direction of value between user web page and FC6A

series by I/O (in, out, i/o) settings.

Think Automation and beyond�

In(read)

out(write)

i/o(read・・・・write)

FC6A seriesUser web page

Page 17: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.1.3 Set link to devices(2)

Think Automation and beyond�

You can select the device

that is being used in main

program of WindLDR from

“Device Tree”.

You can input directly for setting

in link box.

Page 18: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.2 Components overview and function example(1)

・・・・Common settings of each components

Items Description

x X coordinates of component in layer area

y Y coordinates of component in layer area

width Width of layer

height Height of layer

visible Allow you to display or not

x = 0, y = 0

Layer area

x

Think Automation and beyond�

y

You can input number in pixel step to

change the position/ size of components

in layer area.

You can also change the position/ size by

using device link.

Page 19: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.2 Components overview and function example(1)

Below two items cannot be dynamically changed by using device link.

Items Description

Font Text font

Color Text color

Think Automation and beyond�

Color and Font don’t change dynamically,

thus it is impossible to change by linking

device.

Page 20: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.2.1 Set Link/Event(1)

Configuration example of label operation

When set 100 to D0

If D0 increases to 100, label

shows 100.

Think Automation and beyond�

Label function is only capable

of displaying, thus, please set

I/O as “in”. If display of label is changed,

event (!onTextFormat) occurs,

the value is written to linked

device, and D1 becomes 100.

Page 21: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.2.1 Set Link/Event(2)

Configuration example of dynamic change for “Title” that attached on the frame

“Title” is only capable of displaying, and

setting is not required here. Please set I/O

as “in”.

If you input 100 to D0, Title

becomes device value which is

linked to the title.

Think Automation and beyond�

Page 22: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.2.1 Set Link/Event(3)

Configuration example of switch operation

Output to M0, please set I/O as “out” or “i/o”.

Think Automation and beyond�

You can set image as ON and OFF status.

ON OFF

Page 23: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.2.1 Set Link/Event(4)

Configuration example of check box operation

According to the value of

check box, M1 turns ON or OFF.

Think Automation and beyond�

・・・・About event(!onValueChange)If value changes by operation of check

box, linked device turns ON.

However, turn M0 OFF from FC6A

series, display of check box is not

interlocked.

When using Web Page Editor to

operate, please set I/O as “out” or “i/o”.

However, if set I/O as “out”,

value(variable) leaves it as it is when

you operate from FC6A series.

Page 24: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.2.1 Set Link/Event(5)

Grouping Radio buttons

After grouping radio buttons,

Think Automation and beyond�

After grouping radio buttons,

turn one of grouped radio

button ON, the other buttons

will not turn ON together.

Select and group multiple

configured radio buttons.

To set Text in advance will

make configuration items easy

to understand when setting

each radio button.

Page 25: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.2.1 Set Link/Event(6)

Configuration example of radio button

value = 0

value = 1

value = 2

Think Automation and beyond�

Configurable value

increases in the order of

configured radio buttons.

According to the value of radio

button, value of D0 changes.

Same operation is performed in

Event (!onValueChange).

Page 26: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.2.1 Set Link/Event(7)

Push button

Same operation is

performed in Event

Button-down Button-up

Set operation of momentary switch.

Think Automation and beyond�

performed in Event

(!onValueChange)

Page 27: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.2.1 Set Link/Event(8)

Text Input・・・・Set I/O as “in”

・・・・ Set I/O as “out”

Displaying a value of device

which is linked to a device.

Think Automation and beyond�

If you set I/O of device which is linked to

Text as “in”, you can read (display) the

value. If you set I/O as “out”, you can write

(operate) the value.

When you set I/O as “i/o”, write and read

are both available.

Changing a value in text box to

write to device linked.

Event(!onTextChange) occurs

and output to device linked when

Text in text box is changed.

Page 28: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.2.1 Set Link/Event(9)

Trend graph

Think Automation and beyond�

By Linking device of each line, maximum

of 8 data can be displayed as trend graph.

Available to only read (display), please set

I/O as “in”.

Page 29: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.2.2 Set “Goto Screen Button”(1)

Double-click button of component

Goto Screen Button

Think Automation and beyond�

・・・・Select “Jump to page and layer” when page has been saved multiply.

・・・・Select “Jump to URL” if you want to link it to other URL.

Page 30: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.2.2 Set “Goto Screen Button” (2)

Think Automation and beyond�

Select the page that you want to jump,

it can be switched to that page when

button is depressed.

You can specify ID of URL and

layer to link button with target

User Web Page and layer.

Page 31: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.2.3 About Layer (1)

You can use layer function to overlap screen.

Size and

background color

can be set in

each layer.

Displaying layer

Think Automation and beyond�

Layer 0

Layer 1

Layer 2Whole screen

Page 32: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.2.3 About Layer (2)

You can specify the size of layer which is when creating user web page or

displaying browser.

1. Adjust for size of PC environment(browser) for development.

The size of layer is specified automatically in matching with size of browser displayed.

2. Adjust for size of PC environment(screen) for development

The size of layer is specified automatically in matching with size of screen displayed.

Think Automation and beyond�

*If the size of layer area is larger than

browser, layer area will be displayed

with scroll bar when you open it by

browser.

Page 33: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.2.3 About Layer (3)3. If you specify layer area and display size in matching with other size of browser which is different from development environment, you can specify width/ height and position (X-

coordinate, Y-coordinate).

Think Automation and beyond�

When changing the size,

layer size can be referred

on Web Page Editor.

Select “Adjust to the

browser width/ height

when runtime”, when

you use smart-phone.*Image of displaying screen by

landscape smart-phone.

Page 34: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.3 Components usage example

In Web Page Editor, below components can be created by

linking with device of FC6A.

・・・・Numeric input (by Text input function)・・・・Numeric display (by label function)・・・・Alternate switch

Think Automation and beyond�

・・・・Alternate switch

Page 35: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.3.1 Numeric input(1)

Think Automation and beyond�

Place a “Text input”.

Link to device which you want to display on

Text in property.

e.g.

Link:[IDEC:D:D0.word]

IO:[out]

If you set property as above, value is written to

device [D0].

Page 36: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.3.1 Numeric input (2)

Think Automation and beyond�

Write value to device [D0].

Page 37: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.3.2 Numeric display(1)

Think Automation and beyond�

Place a “Label”.

Link to device which you want to display on

Text in property.

e.g.

Link:[IDEC:D:D0.word]

IO:[in]

If you set property as above, value is written to

device [D0].

Page 38: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.3.2 Numeric display(2)

Think Automation and beyond�

Linkage with device [D0] and displays

value.

Page 39: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.3.3 Alternate switch(1)

Import the images of

switches that switch is

power-on and power-off

from Symbol Factory.

Think Automation and beyond�

ONOFF After placing “switch”, set

each of image imported as

ON and OFF.

Page 40: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

3.3.3 Alternate switch(2)

Think Automation and beyond�

Link target device at link of value to

complete a alternate switch.

Image of operation

can be checked by

clicking image to

switch ON/ OFF.

Page 41: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

4. Save User Web Page

Start Web Page Editor

Place components

Flow of creating web page using Web Page Editor

Think Automation and beyond�

Save user web page

Download/ Access

user web page

Simulation

Page 42: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

4. Save User Web Page(1)

Select “OK” after writing the file

name of user web page in “Save

User web page can be separately saved aside from saving as project file.

Think Automation and beyond�

name of user web page in “Save

name”.

Select “Save to local disk” to save

user web page only.

Page 43: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

4. Save User Web Page(2)

Think Automation and beyond�

User web page is saved as child node in Web

Page Editor of project window after saving.

Page 44: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

5. Simulation

Start Web Page Editor

Place Components

Flow of creating web page using Web Page Editor

Think Automation and beyond�

Save user web page

Download/ Access

user web page

Simulation

Page 45: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

5.1 Simulation

1. Set WindLDR as simulation mode.

You can check the operation of user web page without

downloading to FC6A.

Think Automation and beyond�

2. Set mode of Web Page Editor as “RUN”.

*Simulation of Web Page Editor cannot be executed if the

simulation mode of WindLDR is not ON.

Page 46: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

6. Download/Access Web page

Start Web Page Editor

Place components

Flow of creating web page using Web Page Editor

Think Automation and beyond�

Save user web page

Download/ Access

user web page

Simulation

Page 47: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

6.1 Download methods

Download user web page to FC6A HMI module.

Think Automation and beyond�

Put check mark in “Download web page”.

Page 48: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

6.2 Access Web Page((((By URL))))Enter URL directly into Web browser to access.

You can access web page that is downloaded to FC6A HMI module by entering

below URL.

http:// IP address of HMI module: Port No. /viewer/view.htm?pagepath=

filename.page

Think Automation and beyond�

*When downloading multiple pages, you can access the file that you want by only

changing the part after “Pagepath=”.

e.g.)When you want to access Page2.page

http://10.1.102.54:80/viewer/view.htm?pagepath=Page2.page

Page 49: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

6.3 Access User Web Page ((((By HTTP))))(1)

Configuration of redirect target on FC6A HMI module

1. Set redirect target of saved user web page.

Think Automation and beyond�

Page 50: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

Access the page that sets redirect target.

1.Start web browser and enter IP address of FC6A HMI module that is set in

Network settings.

6.3 Access User Web Page(by HTTP)(2)

Think Automation and beyond�

2.After entering configured account name and password, it is allowed to

automatically access user web page that is set in redirect target.

Page 51: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

6.4 Set Base Timer Period

Value of components and period of updating status can be changed by

changing “Base Timer Period (ms)” from settings dialog of Web Page Editor.

*Update period is in common for each component.

Settable display period

Think Automation and beyond�

“Base Timer Period” can be changed

from 100 to 50,000 (ms).

Page 52: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

7. About Web Page Capacity1. When using system web page, memory usage of system web page is

500KB.

2. When using Web Page Editor, memory usage of Web Page Editor

software is 2MB. 2MB500kB 2.5MB

The rest of 2.5MB capacity is available for using user web page. Total of

below files need to be used within 2.5MB.

- Files that made by Web Page Editor and imported images/videos

Think Automation and beyond�

- Files that made by Web Page Editor and imported images/videos

- User web page made by HTML editor or JAVA script

Depending on whether system web page and Web Page Editor is used or not,

available capacity changes. You can select functions in “Web server” tab at

configuration dialog of HMI module.

Page 53: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

7.1 Web Page Capacity(1)

2MB500kB 2.5MB

1. System web page + Web Page Editor

Available capacity for creating web page is 2.5MB.

Think Automation and beyond�

2. System web page + User web page using HTML editor or JAVA script

(Without using Web Page Editor).

500kB 4.5MB

Available capacity for creating web page is 4.5MB.

※※※※Software created by FC5A Web server CPU module can be

reused.

Page 54: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

7.1 Web Page Capacity(2)

2MB 3MB

3. Web Page Editor only

Available capacity for creating web page is 3MB.

4. User web page created by HTML editor or JAVA script.(Without using

Think Automation and beyond�

5MB

4. User web page created by HTML editor or JAVA script.(Without using

system web page and Web Page Editor)

Available capacity for creating web page is 5MB.

*High added value and

professional oriented User Web

Page can be created if HTML

Editor or JAVA script HTML are

available.

Page 55: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

7.2 Capacity confirmation method

You can confirm total capacity and

maximum capacity which are being

Think Automation and beyond�

maximum capacity which are being

saved in download dialog.

Page 56: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

8. Help function

Access Help from Web Page Editor

Think Automation and beyond�

Page 57: FC6ASeriesWebPage Editor Sales Manual PLC/FC6A... · FC6ASeriesWebPage Editor Sales Manual (Product Description ・・・Tutorial) ... Selected and stored in Web Page Editor in WindLDR,

Finally

Since Web server function has been embedded on FC5A series, few users

have knowledge of HTML editor or JAVA script, high costs for creating a easy-

to-follow web page by web designer or development company. A simple

drawing tool is required from market.

To respond to this request, we offer FC6A Web Page Editor with enhanced

remote monitoring/ operating function in order to serve customers in today’s

IoT trend. This tool provides expanded customers an environment which

achieves remote monitoring more simply and efficiently.

Think Automation and beyond�

achieves remote monitoring more simply and efficiently.

The request of remote monitoring is of common desire from who has a

large/small scale application, who has intellectual curiosity. It definitely is a

product which causes customers to be interested if you propose properly.

We wish you continued success!

Electronics& Automation Division

PLC Product Marketing