featurecam setup zero. coordinate system work offsets –g54-g59 –g54 x & y aligned with vice...

15
Featurecam Setup Zero

Post on 20-Dec-2015

258 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Featurecam Setup Zero. Coordinate System Work Offsets –G54-G59 –G54 X & Y aligned with vice step jaw left front –Set G54 Z to height of top of work (type

Featurecam Setup Zero

Page 2: Featurecam Setup Zero. Coordinate System Work Offsets –G54-G59 –G54 X & Y aligned with vice step jaw left front –Set G54 Z to height of top of work (type

Coordinate System

Page 3: Featurecam Setup Zero. Coordinate System Work Offsets –G54-G59 –G54 X & Y aligned with vice step jaw left front –Set G54 Z to height of top of work (type

Work Offsets

• Work Offsets– G54-G59– G54 X & Y

aligned with vice step jaw left front

– Set G54 Z to height of top of work (type number, press F1)

Page 4: Featurecam Setup Zero. Coordinate System Work Offsets –G54-G59 –G54 X & Y aligned with vice step jaw left front –Set G54 Z to height of top of work (type

Offsets

Page 5: Featurecam Setup Zero. Coordinate System Work Offsets –G54-G59 –G54 X & Y aligned with vice step jaw left front –Set G54 Z to height of top of work (type

Setting Work Offset

Page 6: Featurecam Setup Zero. Coordinate System Work Offsets –G54-G59 –G54 X & Y aligned with vice step jaw left front –Set G54 Z to height of top of work (type

PLC Front Panel

Page 7: Featurecam Setup Zero. Coordinate System Work Offsets –G54-G59 –G54 X & Y aligned with vice step jaw left front –Set G54 Z to height of top of work (type

PLC Wiring

• Power Inputs• Signal Inputs• Control

Outputs

Page 8: Featurecam Setup Zero. Coordinate System Work Offsets –G54-G59 –G54 X & Y aligned with vice step jaw left front –Set G54 Z to height of top of work (type

Power Wiring

• Three levels of protection:– PLC logic - shutdown

sequence– PLC output power disconnect– E-Stop shutdown of all

energy sources

Page 9: Featurecam Setup Zero. Coordinate System Work Offsets –G54-G59 –G54 X & Y aligned with vice step jaw left front –Set G54 Z to height of top of work (type

PLC Inputs and Outputs

• Sinking = drawing current• Sourcing = supplying current• Sinking output connects to sourcing input• Sourcing output connects to sinking input

Page 10: Featurecam Setup Zero. Coordinate System Work Offsets –G54-G59 –G54 X & Y aligned with vice step jaw left front –Set G54 Z to height of top of work (type

DL06 Signal Inputs

Page 11: Featurecam Setup Zero. Coordinate System Work Offsets –G54-G59 –G54 X & Y aligned with vice step jaw left front –Set G54 Z to height of top of work (type

Signal Inputs

Page 12: Featurecam Setup Zero. Coordinate System Work Offsets –G54-G59 –G54 X & Y aligned with vice step jaw left front –Set G54 Z to height of top of work (type

Typical Input Device

• The tag indicates that the LOAD (PLC input has a +DC common– this is a sinking output– Sinking output =>

sourcing input

Page 13: Featurecam Setup Zero. Coordinate System Work Offsets –G54-G59 –G54 X & Y aligned with vice step jaw left front –Set G54 Z to height of top of work (type

Another Input Device

• Photosensor – comes in either NPN (sinking) or PNP (sourcing)

Page 14: Featurecam Setup Zero. Coordinate System Work Offsets –G54-G59 –G54 X & Y aligned with vice step jaw left front –Set G54 Z to height of top of work (type

DC Control Outputs

Page 15: Featurecam Setup Zero. Coordinate System Work Offsets –G54-G59 –G54 X & Y aligned with vice step jaw left front –Set G54 Z to height of top of work (type

DC Control Outputs