![Page 1: Features - RECOM Power · The RAC02-GB series are low cost AC/DC power supplies, ideal for PCB mounted, compact, board level industrial applications. They feature universal AC input](https://reader031.vdocuments.net/reader031/viewer/2022020317/5bde05e209d3f2995d8c07a1/html5/thumbnails/1.jpg)
RAC02-GB
ACDC Converter
wwwrecom-powercom REV 12018 PA-1
2 WattSingle Output EMC Class B
DescriptionThe RAC02-GB series are low cost ACDC power supplies ideal for PCB mounted compact board level industrial applications They feature universal AC input voltage range regulated and short-circuit-proof isolated DC outputs low standby power consumption and -25degC to +80degC operating temperature range The RAC02-GB have a built-in Class B FCC Part 15 EMC filter are certified to EN60950 and EN62368 safety standards and come with a three year warranty
Features
Regulated Converter
bull Universal input 85-264VAC
bull lt250mW No load power consumption
bull -25degC to +80degC Operating temperature with derating
bull Class II installations (without FG)
bull Continuous SCP OCP
bull IECENUL60950 amp IECENUL62368 certified
E196683
RAC02-GB
Selection Guide
Part Input Output Output Efficiency Max CapacitiveNumber Voltage Range Voltage Current typ Load (1)
[VAC] [VDC] [mA] [] [microF]RAC02-33SGB 85-264 33 500 63 500RAC02-05SGB 85-264 5 400 63 500RAC02-12SGB 85-264 12 167 68 200RAC02-15SGB 85-264 15 140 63 200RAC02-24SGB 85-264 24 83 63 200
Notes Note1 Measured with all input voltages at +25degC with constant resistant mode at full load
Model Numbering
Ordering ExamplesRAC02-12SGB 12Vout Single Output EMC Class B
Single
nom Output Power
nom Output Voltage
RAC02-__ SGBEMC Class B
ULIECEN60950-1 certifiedULIECEN62368-1 certifiedCANCSA-C222 No 62368 certifiedIECEN62368-1 certifiedCB Report
wwwrecom-powercom REV 12018 PA-2
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
BASIC CHARACTERISTICSParameter Condition Min Typ MaxInternal Input Filter Pi-type
Input Voltage Range (234) nom Vin = 230VAC 85VAC 230VAC 264VAC
Input Current115VAC230VAC
50mA30mA
Inrush Current cold start at +25degC115VAC230VAC
30A40A
No load Power Consumption 180mW 250mW
Input Frequency Range 47Hz 63Hz
Minimum Load 0
Power Factor115VAC230VAC
055042
Start-up Time115VAC230VAC
250ms200ms
2s2s
Hold-up time115VAC230VAC
20ms80ms
Internal Operating Frequency 100 load at nominal Vin 65kHz
Output Ripple and Noise 20MHz BW
0degC to 80degC
33Vout 5Vout
12Vout 15Vout 24Vout
100mVp-p 100mVp-p 200mVp-p 200mVp-p240mVp-p
-25degC to 0degC
33Vout 5Vout
12Vout 15Vout 24Vout
200mVp-p 200mVp-p 300mVp-p 300mVp-p300mVp-p
Efficiency vs Load
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Effic
ienc
y [
]
Output Load []
115VAC230VAC
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Effic
ienc
y [
]
Output Load []
115VAC230VAC
RAC02-12SGBRAC02-05SGB
Notes Note2 No proper operation with DC input voltage Note3 The products were submitted for safety files at AC-Input operation Note4 Refer to line derating graph on page 4
wwwrecom-powercom REV 12018 PA-3
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
PROTECTIONSParameter Type ValueInput Fuse (5) internal fusible resistor 1W1W
Short Circuit Protection (SCP) below 100mW continuous auto recovery
Over Voltage Category OVCII
Over Current Protection (OCP)
33Vout 5Vout
12Vout 15Vout 24Vout
067A - 181A044A - 120A018A - 050A 015A - 042A 009A - 025A
hiccup mode
Class of Equipment Class II
Isolation Voltage (6) IP to OP rated for 1 minute 3kVAC
Isolation Resistance 100MW min
Insulation Grade reinforced
Leakage Current IP to OP 025mA max
REGULATIONSParameter Condition ValueOutput Accuracy -25degC to +80degC plusmn60 max
Line Regulation -25degC to +80degC plusmn20 max
Load Regulation -25degC to +80degC 60 max
Deviation vs Load
6
4
0
-4
2
-2
-6
Devi
atio
n [
]
0 10 20 30 40 50 60 70 80 90 100
Output Load []
115VAC230VAC
6
4
0
-4
2
-2
-6
Devi
atio
n [
]
0 10 20 30 40 50 60 70 80 90 100
Output Load []
115VAC230VAC
Protection Circuit
RAC02-12SGB RAC02-24SGB
Notes Note5 Refer to local safety regulations if input over-current protection is also required Note6 For repeat Hi-Pot testing reduce the time andor the test voltage Note7 For operation at 230VAC an external MOV is recommended The Varistor should comply with IEC-61051-2 eg EPCOS S14 series
FUSE
U
-VOUT
+VOUT
L N
wwwrecom-powercom REV 12018 PA-4
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
SAFETY AND CERTIFICATIONSCertificate Type (Safety) Report File Number Standard
Information Technology Equipment General Requirements for Safety E196683-A5UL60950-1 2nd Edition 2014
CANCSA-C222 No 60950-1 2nd Edition 2015
Information Technology Equipment General Requirements for Safety 16BAS10048 11
SA1804152L01001IEC60950-12005 2nd Edition + Am22013
EN60950-12006 + A22013
Information Technology Equipment General Requirements for Safety (CB Scheme)
16BAS10048 11 IEC60950-12005 2nd Edition + Am22013
continued on next page
ENVIRONMENTALParameter Condition Value
Operating Temperature Range natural convection 01msfull load -25degC to +70degC
refer to derating graph -25degC to +80degC
Maximum Case Temperature +120degC
Temperature Coefficient 003K
Operating Altitude (8) 4000m
Operating Humidity non-condensing 5 - 95 RH max
Pollution Degree PD2
Shock 10-150Hz 2G 10min1cycle period 60min each along xyz axes
Vibration according to MIL-STD-202G 20G11ms pulse 3 times at each x y z axes
MTBF (9) according to MIL-HDBK-217F method 2+25degC+70degC
1691 x 103 hours424 x 103 hours
-25 -10 5 20 35 50 80 95
100
80
60
40
90
70
50
30
20
10
0
Outp
ut L
oad
[]
Ambient Temperature [degC]
6570
all other typesRAC02-33SG
Derating Graph( Chamber and natural convection 01ms) Line Derating
100
80
60
40
90
70
50
30
20
10
0
Outp
ut L
oad
[]
Input Voltage [VAC]
85 90 264
Notes Note8 Recognized by UL for safe operation up to 4000m High altitude operation may impact the performance and lifetime Contact TechsupportATRECOM-POWERcom for advice Note9 Based on calculation for 5Vout
wwwrecom-powercom REV 12018 PA-5
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
DIMENSION AND PHYSICAL CHARACTERISTICSParameter Type Value
MaterialcasePCB
black plastic (UL94V-2) FR4 (UL94V-0)
Dimension (LxWxH) 337 x 222 x 190mm
Weight 12g typ
continued on next page
Certificate Type (Safety) Report File Number Standard AudioVideo information and communication technology equipment - Part1 Safety requirements
E196683-A5E196683-A6001
UL62368-1 2nd EditionCANCSA-C222 No 62368-1-14
AudioVideo information and communication technology equipment - Part1 Safety requirements
16BCS1004811IEC62368-12014 2nd EditionEN62368-12014+A112017
AudioVideo information and communication technology equipment - Part1 Safety requirements (CB Scheme)
SA1804152S 001 IEC62368-12014 2nd Edition
RoHS2 RoHS 201165EU
EMC Compliance Condition Standard CriterionElectromagnetic compatibility of multimedia equipment - Emission requirements
EA1804152E 01001
EN550322015 Class B
Information technology equipment - Immunity characteristics - Limits and methods of measurement
EN550242010+A12015
ESD Electrostatic discharge immunity testAir plusmn2 4 8kV
Contact plusmn2 4kVEN61000-4-22009 Criteria A
Radiated radio-frequency electromagnetic field immunity test 3Vm EN61000-4-32006 + A22010 Criteria A
Fast Transient and Burst Immunity AC Power Port plusmn1kV EN61000-4-42012 Criteria A
Surge Immunity AC Power Port L-N plusmn1kV EN61000-4-52014 Criteria B
Immunity to conducted disturbances induced by radio-frequency fields AC Power Port 3V EN61000-4-62014 Criteria A
Immunity to conducted disturbances induced by radio-frequency fields 50Hz 1Am IEC61000-4-82009 Criteria A
Voltage Dips and Interruption
Voltage Dips gt95 EN61000-4-112004 Criteria A
Voltage Dips 30 EN61000-4-112004 Criteria B
Voltage Interruptions gt95 EN61000-4-112004 Criteria B
Limits of Voltage Fluctuations amp Flicker EN61000-3-32013
wwwrecom-powercom REV 12018 PA-6
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
PACKAGING INFORMATIONParameter Type ValuePackaging Dimension (LxWxH) tube 4700 x 364 x 264mm
Packaging Quantity 20pcs
Storage Temperature Range -25degC to +85degC
Storage Humidity non-condensing 5 - 95 RH max
The product information and specifications may be subject to changes even without prior written noticeThe product has been designed for various applications its suitability lies in the responsibility of each customer The products are not authorized for use in safety-critical applications without RECOMrsquos explicit written consent A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life inflict bodily harm or damage property The applicant shall indemnify and hold harmless RECOM its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications
Dimension Drawing (mm)
337
Bottom View Top View
285
280
222
762
1524
190
37
plusmn0
5
Oslash08plusmn003
embossed logo
254
254
3
3
4 4
1
12
2
Pin Connections Pin Single 1 VAC in (L) 2 VAC in (N) 3 -Vout 4 +VoutTolerance xxx= plusmn05mmPin width plusmn005mm
Recommended Footprint Details
![Page 2: Features - RECOM Power · The RAC02-GB series are low cost AC/DC power supplies, ideal for PCB mounted, compact, board level industrial applications. They feature universal AC input](https://reader031.vdocuments.net/reader031/viewer/2022020317/5bde05e209d3f2995d8c07a1/html5/thumbnails/2.jpg)
wwwrecom-powercom REV 12018 PA-2
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
BASIC CHARACTERISTICSParameter Condition Min Typ MaxInternal Input Filter Pi-type
Input Voltage Range (234) nom Vin = 230VAC 85VAC 230VAC 264VAC
Input Current115VAC230VAC
50mA30mA
Inrush Current cold start at +25degC115VAC230VAC
30A40A
No load Power Consumption 180mW 250mW
Input Frequency Range 47Hz 63Hz
Minimum Load 0
Power Factor115VAC230VAC
055042
Start-up Time115VAC230VAC
250ms200ms
2s2s
Hold-up time115VAC230VAC
20ms80ms
Internal Operating Frequency 100 load at nominal Vin 65kHz
Output Ripple and Noise 20MHz BW
0degC to 80degC
33Vout 5Vout
12Vout 15Vout 24Vout
100mVp-p 100mVp-p 200mVp-p 200mVp-p240mVp-p
-25degC to 0degC
33Vout 5Vout
12Vout 15Vout 24Vout
200mVp-p 200mVp-p 300mVp-p 300mVp-p300mVp-p
Efficiency vs Load
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Effic
ienc
y [
]
Output Load []
115VAC230VAC
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Effic
ienc
y [
]
Output Load []
115VAC230VAC
RAC02-12SGBRAC02-05SGB
Notes Note2 No proper operation with DC input voltage Note3 The products were submitted for safety files at AC-Input operation Note4 Refer to line derating graph on page 4
wwwrecom-powercom REV 12018 PA-3
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
PROTECTIONSParameter Type ValueInput Fuse (5) internal fusible resistor 1W1W
Short Circuit Protection (SCP) below 100mW continuous auto recovery
Over Voltage Category OVCII
Over Current Protection (OCP)
33Vout 5Vout
12Vout 15Vout 24Vout
067A - 181A044A - 120A018A - 050A 015A - 042A 009A - 025A
hiccup mode
Class of Equipment Class II
Isolation Voltage (6) IP to OP rated for 1 minute 3kVAC
Isolation Resistance 100MW min
Insulation Grade reinforced
Leakage Current IP to OP 025mA max
REGULATIONSParameter Condition ValueOutput Accuracy -25degC to +80degC plusmn60 max
Line Regulation -25degC to +80degC plusmn20 max
Load Regulation -25degC to +80degC 60 max
Deviation vs Load
6
4
0
-4
2
-2
-6
Devi
atio
n [
]
0 10 20 30 40 50 60 70 80 90 100
Output Load []
115VAC230VAC
6
4
0
-4
2
-2
-6
Devi
atio
n [
]
0 10 20 30 40 50 60 70 80 90 100
Output Load []
115VAC230VAC
Protection Circuit
RAC02-12SGB RAC02-24SGB
Notes Note5 Refer to local safety regulations if input over-current protection is also required Note6 For repeat Hi-Pot testing reduce the time andor the test voltage Note7 For operation at 230VAC an external MOV is recommended The Varistor should comply with IEC-61051-2 eg EPCOS S14 series
FUSE
U
-VOUT
+VOUT
L N
wwwrecom-powercom REV 12018 PA-4
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
SAFETY AND CERTIFICATIONSCertificate Type (Safety) Report File Number Standard
Information Technology Equipment General Requirements for Safety E196683-A5UL60950-1 2nd Edition 2014
CANCSA-C222 No 60950-1 2nd Edition 2015
Information Technology Equipment General Requirements for Safety 16BAS10048 11
SA1804152L01001IEC60950-12005 2nd Edition + Am22013
EN60950-12006 + A22013
Information Technology Equipment General Requirements for Safety (CB Scheme)
16BAS10048 11 IEC60950-12005 2nd Edition + Am22013
continued on next page
ENVIRONMENTALParameter Condition Value
Operating Temperature Range natural convection 01msfull load -25degC to +70degC
refer to derating graph -25degC to +80degC
Maximum Case Temperature +120degC
Temperature Coefficient 003K
Operating Altitude (8) 4000m
Operating Humidity non-condensing 5 - 95 RH max
Pollution Degree PD2
Shock 10-150Hz 2G 10min1cycle period 60min each along xyz axes
Vibration according to MIL-STD-202G 20G11ms pulse 3 times at each x y z axes
MTBF (9) according to MIL-HDBK-217F method 2+25degC+70degC
1691 x 103 hours424 x 103 hours
-25 -10 5 20 35 50 80 95
100
80
60
40
90
70
50
30
20
10
0
Outp
ut L
oad
[]
Ambient Temperature [degC]
6570
all other typesRAC02-33SG
Derating Graph( Chamber and natural convection 01ms) Line Derating
100
80
60
40
90
70
50
30
20
10
0
Outp
ut L
oad
[]
Input Voltage [VAC]
85 90 264
Notes Note8 Recognized by UL for safe operation up to 4000m High altitude operation may impact the performance and lifetime Contact TechsupportATRECOM-POWERcom for advice Note9 Based on calculation for 5Vout
wwwrecom-powercom REV 12018 PA-5
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
DIMENSION AND PHYSICAL CHARACTERISTICSParameter Type Value
MaterialcasePCB
black plastic (UL94V-2) FR4 (UL94V-0)
Dimension (LxWxH) 337 x 222 x 190mm
Weight 12g typ
continued on next page
Certificate Type (Safety) Report File Number Standard AudioVideo information and communication technology equipment - Part1 Safety requirements
E196683-A5E196683-A6001
UL62368-1 2nd EditionCANCSA-C222 No 62368-1-14
AudioVideo information and communication technology equipment - Part1 Safety requirements
16BCS1004811IEC62368-12014 2nd EditionEN62368-12014+A112017
AudioVideo information and communication technology equipment - Part1 Safety requirements (CB Scheme)
SA1804152S 001 IEC62368-12014 2nd Edition
RoHS2 RoHS 201165EU
EMC Compliance Condition Standard CriterionElectromagnetic compatibility of multimedia equipment - Emission requirements
EA1804152E 01001
EN550322015 Class B
Information technology equipment - Immunity characteristics - Limits and methods of measurement
EN550242010+A12015
ESD Electrostatic discharge immunity testAir plusmn2 4 8kV
Contact plusmn2 4kVEN61000-4-22009 Criteria A
Radiated radio-frequency electromagnetic field immunity test 3Vm EN61000-4-32006 + A22010 Criteria A
Fast Transient and Burst Immunity AC Power Port plusmn1kV EN61000-4-42012 Criteria A
Surge Immunity AC Power Port L-N plusmn1kV EN61000-4-52014 Criteria B
Immunity to conducted disturbances induced by radio-frequency fields AC Power Port 3V EN61000-4-62014 Criteria A
Immunity to conducted disturbances induced by radio-frequency fields 50Hz 1Am IEC61000-4-82009 Criteria A
Voltage Dips and Interruption
Voltage Dips gt95 EN61000-4-112004 Criteria A
Voltage Dips 30 EN61000-4-112004 Criteria B
Voltage Interruptions gt95 EN61000-4-112004 Criteria B
Limits of Voltage Fluctuations amp Flicker EN61000-3-32013
wwwrecom-powercom REV 12018 PA-6
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
PACKAGING INFORMATIONParameter Type ValuePackaging Dimension (LxWxH) tube 4700 x 364 x 264mm
Packaging Quantity 20pcs
Storage Temperature Range -25degC to +85degC
Storage Humidity non-condensing 5 - 95 RH max
The product information and specifications may be subject to changes even without prior written noticeThe product has been designed for various applications its suitability lies in the responsibility of each customer The products are not authorized for use in safety-critical applications without RECOMrsquos explicit written consent A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life inflict bodily harm or damage property The applicant shall indemnify and hold harmless RECOM its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications
Dimension Drawing (mm)
337
Bottom View Top View
285
280
222
762
1524
190
37
plusmn0
5
Oslash08plusmn003
embossed logo
254
254
3
3
4 4
1
12
2
Pin Connections Pin Single 1 VAC in (L) 2 VAC in (N) 3 -Vout 4 +VoutTolerance xxx= plusmn05mmPin width plusmn005mm
Recommended Footprint Details
![Page 3: Features - RECOM Power · The RAC02-GB series are low cost AC/DC power supplies, ideal for PCB mounted, compact, board level industrial applications. They feature universal AC input](https://reader031.vdocuments.net/reader031/viewer/2022020317/5bde05e209d3f2995d8c07a1/html5/thumbnails/3.jpg)
wwwrecom-powercom REV 12018 PA-3
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
PROTECTIONSParameter Type ValueInput Fuse (5) internal fusible resistor 1W1W
Short Circuit Protection (SCP) below 100mW continuous auto recovery
Over Voltage Category OVCII
Over Current Protection (OCP)
33Vout 5Vout
12Vout 15Vout 24Vout
067A - 181A044A - 120A018A - 050A 015A - 042A 009A - 025A
hiccup mode
Class of Equipment Class II
Isolation Voltage (6) IP to OP rated for 1 minute 3kVAC
Isolation Resistance 100MW min
Insulation Grade reinforced
Leakage Current IP to OP 025mA max
REGULATIONSParameter Condition ValueOutput Accuracy -25degC to +80degC plusmn60 max
Line Regulation -25degC to +80degC plusmn20 max
Load Regulation -25degC to +80degC 60 max
Deviation vs Load
6
4
0
-4
2
-2
-6
Devi
atio
n [
]
0 10 20 30 40 50 60 70 80 90 100
Output Load []
115VAC230VAC
6
4
0
-4
2
-2
-6
Devi
atio
n [
]
0 10 20 30 40 50 60 70 80 90 100
Output Load []
115VAC230VAC
Protection Circuit
RAC02-12SGB RAC02-24SGB
Notes Note5 Refer to local safety regulations if input over-current protection is also required Note6 For repeat Hi-Pot testing reduce the time andor the test voltage Note7 For operation at 230VAC an external MOV is recommended The Varistor should comply with IEC-61051-2 eg EPCOS S14 series
FUSE
U
-VOUT
+VOUT
L N
wwwrecom-powercom REV 12018 PA-4
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
SAFETY AND CERTIFICATIONSCertificate Type (Safety) Report File Number Standard
Information Technology Equipment General Requirements for Safety E196683-A5UL60950-1 2nd Edition 2014
CANCSA-C222 No 60950-1 2nd Edition 2015
Information Technology Equipment General Requirements for Safety 16BAS10048 11
SA1804152L01001IEC60950-12005 2nd Edition + Am22013
EN60950-12006 + A22013
Information Technology Equipment General Requirements for Safety (CB Scheme)
16BAS10048 11 IEC60950-12005 2nd Edition + Am22013
continued on next page
ENVIRONMENTALParameter Condition Value
Operating Temperature Range natural convection 01msfull load -25degC to +70degC
refer to derating graph -25degC to +80degC
Maximum Case Temperature +120degC
Temperature Coefficient 003K
Operating Altitude (8) 4000m
Operating Humidity non-condensing 5 - 95 RH max
Pollution Degree PD2
Shock 10-150Hz 2G 10min1cycle period 60min each along xyz axes
Vibration according to MIL-STD-202G 20G11ms pulse 3 times at each x y z axes
MTBF (9) according to MIL-HDBK-217F method 2+25degC+70degC
1691 x 103 hours424 x 103 hours
-25 -10 5 20 35 50 80 95
100
80
60
40
90
70
50
30
20
10
0
Outp
ut L
oad
[]
Ambient Temperature [degC]
6570
all other typesRAC02-33SG
Derating Graph( Chamber and natural convection 01ms) Line Derating
100
80
60
40
90
70
50
30
20
10
0
Outp
ut L
oad
[]
Input Voltage [VAC]
85 90 264
Notes Note8 Recognized by UL for safe operation up to 4000m High altitude operation may impact the performance and lifetime Contact TechsupportATRECOM-POWERcom for advice Note9 Based on calculation for 5Vout
wwwrecom-powercom REV 12018 PA-5
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
DIMENSION AND PHYSICAL CHARACTERISTICSParameter Type Value
MaterialcasePCB
black plastic (UL94V-2) FR4 (UL94V-0)
Dimension (LxWxH) 337 x 222 x 190mm
Weight 12g typ
continued on next page
Certificate Type (Safety) Report File Number Standard AudioVideo information and communication technology equipment - Part1 Safety requirements
E196683-A5E196683-A6001
UL62368-1 2nd EditionCANCSA-C222 No 62368-1-14
AudioVideo information and communication technology equipment - Part1 Safety requirements
16BCS1004811IEC62368-12014 2nd EditionEN62368-12014+A112017
AudioVideo information and communication technology equipment - Part1 Safety requirements (CB Scheme)
SA1804152S 001 IEC62368-12014 2nd Edition
RoHS2 RoHS 201165EU
EMC Compliance Condition Standard CriterionElectromagnetic compatibility of multimedia equipment - Emission requirements
EA1804152E 01001
EN550322015 Class B
Information technology equipment - Immunity characteristics - Limits and methods of measurement
EN550242010+A12015
ESD Electrostatic discharge immunity testAir plusmn2 4 8kV
Contact plusmn2 4kVEN61000-4-22009 Criteria A
Radiated radio-frequency electromagnetic field immunity test 3Vm EN61000-4-32006 + A22010 Criteria A
Fast Transient and Burst Immunity AC Power Port plusmn1kV EN61000-4-42012 Criteria A
Surge Immunity AC Power Port L-N plusmn1kV EN61000-4-52014 Criteria B
Immunity to conducted disturbances induced by radio-frequency fields AC Power Port 3V EN61000-4-62014 Criteria A
Immunity to conducted disturbances induced by radio-frequency fields 50Hz 1Am IEC61000-4-82009 Criteria A
Voltage Dips and Interruption
Voltage Dips gt95 EN61000-4-112004 Criteria A
Voltage Dips 30 EN61000-4-112004 Criteria B
Voltage Interruptions gt95 EN61000-4-112004 Criteria B
Limits of Voltage Fluctuations amp Flicker EN61000-3-32013
wwwrecom-powercom REV 12018 PA-6
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
PACKAGING INFORMATIONParameter Type ValuePackaging Dimension (LxWxH) tube 4700 x 364 x 264mm
Packaging Quantity 20pcs
Storage Temperature Range -25degC to +85degC
Storage Humidity non-condensing 5 - 95 RH max
The product information and specifications may be subject to changes even without prior written noticeThe product has been designed for various applications its suitability lies in the responsibility of each customer The products are not authorized for use in safety-critical applications without RECOMrsquos explicit written consent A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life inflict bodily harm or damage property The applicant shall indemnify and hold harmless RECOM its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications
Dimension Drawing (mm)
337
Bottom View Top View
285
280
222
762
1524
190
37
plusmn0
5
Oslash08plusmn003
embossed logo
254
254
3
3
4 4
1
12
2
Pin Connections Pin Single 1 VAC in (L) 2 VAC in (N) 3 -Vout 4 +VoutTolerance xxx= plusmn05mmPin width plusmn005mm
Recommended Footprint Details
![Page 4: Features - RECOM Power · The RAC02-GB series are low cost AC/DC power supplies, ideal for PCB mounted, compact, board level industrial applications. They feature universal AC input](https://reader031.vdocuments.net/reader031/viewer/2022020317/5bde05e209d3f2995d8c07a1/html5/thumbnails/4.jpg)
wwwrecom-powercom REV 12018 PA-4
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
SAFETY AND CERTIFICATIONSCertificate Type (Safety) Report File Number Standard
Information Technology Equipment General Requirements for Safety E196683-A5UL60950-1 2nd Edition 2014
CANCSA-C222 No 60950-1 2nd Edition 2015
Information Technology Equipment General Requirements for Safety 16BAS10048 11
SA1804152L01001IEC60950-12005 2nd Edition + Am22013
EN60950-12006 + A22013
Information Technology Equipment General Requirements for Safety (CB Scheme)
16BAS10048 11 IEC60950-12005 2nd Edition + Am22013
continued on next page
ENVIRONMENTALParameter Condition Value
Operating Temperature Range natural convection 01msfull load -25degC to +70degC
refer to derating graph -25degC to +80degC
Maximum Case Temperature +120degC
Temperature Coefficient 003K
Operating Altitude (8) 4000m
Operating Humidity non-condensing 5 - 95 RH max
Pollution Degree PD2
Shock 10-150Hz 2G 10min1cycle period 60min each along xyz axes
Vibration according to MIL-STD-202G 20G11ms pulse 3 times at each x y z axes
MTBF (9) according to MIL-HDBK-217F method 2+25degC+70degC
1691 x 103 hours424 x 103 hours
-25 -10 5 20 35 50 80 95
100
80
60
40
90
70
50
30
20
10
0
Outp
ut L
oad
[]
Ambient Temperature [degC]
6570
all other typesRAC02-33SG
Derating Graph( Chamber and natural convection 01ms) Line Derating
100
80
60
40
90
70
50
30
20
10
0
Outp
ut L
oad
[]
Input Voltage [VAC]
85 90 264
Notes Note8 Recognized by UL for safe operation up to 4000m High altitude operation may impact the performance and lifetime Contact TechsupportATRECOM-POWERcom for advice Note9 Based on calculation for 5Vout
wwwrecom-powercom REV 12018 PA-5
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
DIMENSION AND PHYSICAL CHARACTERISTICSParameter Type Value
MaterialcasePCB
black plastic (UL94V-2) FR4 (UL94V-0)
Dimension (LxWxH) 337 x 222 x 190mm
Weight 12g typ
continued on next page
Certificate Type (Safety) Report File Number Standard AudioVideo information and communication technology equipment - Part1 Safety requirements
E196683-A5E196683-A6001
UL62368-1 2nd EditionCANCSA-C222 No 62368-1-14
AudioVideo information and communication technology equipment - Part1 Safety requirements
16BCS1004811IEC62368-12014 2nd EditionEN62368-12014+A112017
AudioVideo information and communication technology equipment - Part1 Safety requirements (CB Scheme)
SA1804152S 001 IEC62368-12014 2nd Edition
RoHS2 RoHS 201165EU
EMC Compliance Condition Standard CriterionElectromagnetic compatibility of multimedia equipment - Emission requirements
EA1804152E 01001
EN550322015 Class B
Information technology equipment - Immunity characteristics - Limits and methods of measurement
EN550242010+A12015
ESD Electrostatic discharge immunity testAir plusmn2 4 8kV
Contact plusmn2 4kVEN61000-4-22009 Criteria A
Radiated radio-frequency electromagnetic field immunity test 3Vm EN61000-4-32006 + A22010 Criteria A
Fast Transient and Burst Immunity AC Power Port plusmn1kV EN61000-4-42012 Criteria A
Surge Immunity AC Power Port L-N plusmn1kV EN61000-4-52014 Criteria B
Immunity to conducted disturbances induced by radio-frequency fields AC Power Port 3V EN61000-4-62014 Criteria A
Immunity to conducted disturbances induced by radio-frequency fields 50Hz 1Am IEC61000-4-82009 Criteria A
Voltage Dips and Interruption
Voltage Dips gt95 EN61000-4-112004 Criteria A
Voltage Dips 30 EN61000-4-112004 Criteria B
Voltage Interruptions gt95 EN61000-4-112004 Criteria B
Limits of Voltage Fluctuations amp Flicker EN61000-3-32013
wwwrecom-powercom REV 12018 PA-6
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
PACKAGING INFORMATIONParameter Type ValuePackaging Dimension (LxWxH) tube 4700 x 364 x 264mm
Packaging Quantity 20pcs
Storage Temperature Range -25degC to +85degC
Storage Humidity non-condensing 5 - 95 RH max
The product information and specifications may be subject to changes even without prior written noticeThe product has been designed for various applications its suitability lies in the responsibility of each customer The products are not authorized for use in safety-critical applications without RECOMrsquos explicit written consent A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life inflict bodily harm or damage property The applicant shall indemnify and hold harmless RECOM its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications
Dimension Drawing (mm)
337
Bottom View Top View
285
280
222
762
1524
190
37
plusmn0
5
Oslash08plusmn003
embossed logo
254
254
3
3
4 4
1
12
2
Pin Connections Pin Single 1 VAC in (L) 2 VAC in (N) 3 -Vout 4 +VoutTolerance xxx= plusmn05mmPin width plusmn005mm
Recommended Footprint Details
![Page 5: Features - RECOM Power · The RAC02-GB series are low cost AC/DC power supplies, ideal for PCB mounted, compact, board level industrial applications. They feature universal AC input](https://reader031.vdocuments.net/reader031/viewer/2022020317/5bde05e209d3f2995d8c07a1/html5/thumbnails/5.jpg)
wwwrecom-powercom REV 12018 PA-5
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
DIMENSION AND PHYSICAL CHARACTERISTICSParameter Type Value
MaterialcasePCB
black plastic (UL94V-2) FR4 (UL94V-0)
Dimension (LxWxH) 337 x 222 x 190mm
Weight 12g typ
continued on next page
Certificate Type (Safety) Report File Number Standard AudioVideo information and communication technology equipment - Part1 Safety requirements
E196683-A5E196683-A6001
UL62368-1 2nd EditionCANCSA-C222 No 62368-1-14
AudioVideo information and communication technology equipment - Part1 Safety requirements
16BCS1004811IEC62368-12014 2nd EditionEN62368-12014+A112017
AudioVideo information and communication technology equipment - Part1 Safety requirements (CB Scheme)
SA1804152S 001 IEC62368-12014 2nd Edition
RoHS2 RoHS 201165EU
EMC Compliance Condition Standard CriterionElectromagnetic compatibility of multimedia equipment - Emission requirements
EA1804152E 01001
EN550322015 Class B
Information technology equipment - Immunity characteristics - Limits and methods of measurement
EN550242010+A12015
ESD Electrostatic discharge immunity testAir plusmn2 4 8kV
Contact plusmn2 4kVEN61000-4-22009 Criteria A
Radiated radio-frequency electromagnetic field immunity test 3Vm EN61000-4-32006 + A22010 Criteria A
Fast Transient and Burst Immunity AC Power Port plusmn1kV EN61000-4-42012 Criteria A
Surge Immunity AC Power Port L-N plusmn1kV EN61000-4-52014 Criteria B
Immunity to conducted disturbances induced by radio-frequency fields AC Power Port 3V EN61000-4-62014 Criteria A
Immunity to conducted disturbances induced by radio-frequency fields 50Hz 1Am IEC61000-4-82009 Criteria A
Voltage Dips and Interruption
Voltage Dips gt95 EN61000-4-112004 Criteria A
Voltage Dips 30 EN61000-4-112004 Criteria B
Voltage Interruptions gt95 EN61000-4-112004 Criteria B
Limits of Voltage Fluctuations amp Flicker EN61000-3-32013
wwwrecom-powercom REV 12018 PA-6
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
PACKAGING INFORMATIONParameter Type ValuePackaging Dimension (LxWxH) tube 4700 x 364 x 264mm
Packaging Quantity 20pcs
Storage Temperature Range -25degC to +85degC
Storage Humidity non-condensing 5 - 95 RH max
The product information and specifications may be subject to changes even without prior written noticeThe product has been designed for various applications its suitability lies in the responsibility of each customer The products are not authorized for use in safety-critical applications without RECOMrsquos explicit written consent A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life inflict bodily harm or damage property The applicant shall indemnify and hold harmless RECOM its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications
Dimension Drawing (mm)
337
Bottom View Top View
285
280
222
762
1524
190
37
plusmn0
5
Oslash08plusmn003
embossed logo
254
254
3
3
4 4
1
12
2
Pin Connections Pin Single 1 VAC in (L) 2 VAC in (N) 3 -Vout 4 +VoutTolerance xxx= plusmn05mmPin width plusmn005mm
Recommended Footprint Details
![Page 6: Features - RECOM Power · The RAC02-GB series are low cost AC/DC power supplies, ideal for PCB mounted, compact, board level industrial applications. They feature universal AC input](https://reader031.vdocuments.net/reader031/viewer/2022020317/5bde05e209d3f2995d8c07a1/html5/thumbnails/6.jpg)
wwwrecom-powercom REV 12018 PA-6
ACDC ConverterSpecifications (measured Ta= 25degC nom Vin (115230VAC) full load and after warm-up unless otherwise stated)
RAC02-GBSeries
PACKAGING INFORMATIONParameter Type ValuePackaging Dimension (LxWxH) tube 4700 x 364 x 264mm
Packaging Quantity 20pcs
Storage Temperature Range -25degC to +85degC
Storage Humidity non-condensing 5 - 95 RH max
The product information and specifications may be subject to changes even without prior written noticeThe product has been designed for various applications its suitability lies in the responsibility of each customer The products are not authorized for use in safety-critical applications without RECOMrsquos explicit written consent A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life inflict bodily harm or damage property The applicant shall indemnify and hold harmless RECOM its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications
Dimension Drawing (mm)
337
Bottom View Top View
285
280
222
762
1524
190
37
plusmn0
5
Oslash08plusmn003
embossed logo
254
254
3
3
4 4
1
12
2
Pin Connections Pin Single 1 VAC in (L) 2 VAC in (N) 3 -Vout 4 +VoutTolerance xxx= plusmn05mmPin width plusmn005mm