8/14 T4614 United States PH: 810-653-9626 FX: 810-653-8714 Canada PH: 519-332-6711 FX: 519-332-8610 www.fernco.com Fernco Flexible Coupling Installation IN GROUND APPLICATION - For sewer, drain, waste and vent piping. Loosen the stainless steel clamps. Do not remove clamps from coupling. Slide coupling over one pipe end. Insert second pipe. Center pipe ends inside of coupling. Tighten clamps to 60 inch-lbs. of torque. Pressure test* before backfilling or concealing joint. Bed and backfill properly. *Maximum test pressure 4.3 PSI (29.6 KPA) Fernco flexible couplings can be used to couple pipe at a break or lateral insertion. Cut and remove pipe section. Loosen clamps. Slide coupling assembly over one pipe exposing the pipe end. Insert new pipe or fitting then slide flexible coupling over new and old pipe ends. Tighten clamps to 60 inch-lbs. of torque. Pressure test* before backfilling or concealing joint. Bed and backfill properly.

Upload: others

Post on 26-Jan-2022

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Fernco Flexible Coupling Installation - api.ferguson.com

8/14 T4614

United StatesPH: 810-653-9626FX: 810-653-8714

CanadaPH: 519-332-6711FX: 519-332-8610www.fernco.com

Fernco Flexible Coupling InstallationIN GROUND APPLICATION - For sewer, drain, waste and vent piping.

Loosen the stainless steel clamps. Do not remove clamps from coupling.

Slide coupling over one pipe end. Insert second pipe. Center pipe ends inside of coupling.

Tighten clamps to 60 inch-lbs. of torque.

Pressure test* before backfilling or concealing joint. Bed and backfill properly.

*Maximum test pressure4.3 PSI (29.6 KPA)

Fernco flexible couplings can be used to couple pipe at a break or lateral insertion.

Cut and remove pipe section. Loosen clamps. Slide coupling assembly over one pipe exposing the pipe end.

Insert new pipe or fitting then slide flexible coupling over new and old pipe ends.

Tighten clamps to 60 inch-lbs. of torque. Pressure test* before backfilling or concealing joint. Bed and backfill properly.

Page 2: Fernco Flexible Coupling Installation - api.ferguson.com

8/14 T4714

United StatesPH: 810-653-9626FX: 810-653-8714

CanadaPH: 519-332-6711FX: 519-332-8610www.fernco.com

Fernco Flexible Coupling InstallationIN HOUSE APPLICATION - For sewer, drain, waste and vent piping.

Loosen the stainless steel clamps. Do not remove clamps from coupling.

Slide coupling over one pipe end. Insert second pipe. Center pipe ends inside of coupling.

Tighten clamps to 60 inch-lbs. of torque.

Support pipe and pressure test* for leaks before concealing joint.

*Maximum test pressure4.3 PSI (29.6 KPA)