CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
GROUNDSNOWLOAD(LB)
WINDSPEED(MPH)
SEISMICDESIGN
CATEGORY
SUBJECT TO DAMAGE FROM
WEATHERINGFROST LINE
DEPTHTERMITE DECAY
WINTERDESIGNTEMP
ICE SHIELDUNDERLAYREQUIRED
FLOODHAZARD
BUILDING CODE COMPLIANCE
RESIDENCE FOR:SITE ADDRESS:
PHONE:E-MAIL:
- Attention CA, OR, WA, and NV residents: Our house plans do not meet Earthquake Seismic/Windcode requirements.
- Attention GA, SC, and NC Coastal residents: Plans may have to be engineered to meet localHurricane/Wind codes.
- Attention AL, AZ, CO, CT, DE, FL, ID, LA, MD, MA, MN, NV, NH, NJ, NY, OH, PN, UT, and VAresidents: Plans may have to be engineered to meet local building codes. Please call your localbuilding department before placing order.
Some cities and states now require that a licensed architect or engineer review and "seal" a blueprint,or officially approve it, prior to construction. Prior to application for a building permit or the start ofactual construction, we strongly advise that you consult your local building official who can tell you ifsuch a review is required.
HOUSE AREAS
BUILDER:ADDRESS:
PHONE:E-MAIL:
ENGINEER:ADDRESS:
PHONE:E-MAIL:
ARCHITECT:ADDRESS:
PHONE:E-MAIL:
THE ABOVE AREA CALCULATIONS ARE BASED ON THE METHOD LAID OUT IN
ANSI STANDARD Z765
A-00-0
COVER PAGE
03-0
PASSIVE SHED 1
20 DECEMBER, 20
AutChec
ARCHITECTURAL
A-00-1 CONSTRUCTION ASSEMBLIESA-00-2 LEED-H RATING SYSTEM CHECKLISTA-00-3 NAHB GREEN BUILDING STANDARDA-01-1 ELEVATIONSA-01-2 ELEVATIONSA-02-1 ENTRY LEVEL FLOOR PLAN
A-03-1 BUILDING SECTIONA-04-1 DETAILS 1A-04-2 DETAILS 2A-05-1 FOUNDATION PLANA-05-2 ROOF FRAMING PLANA-06-1 WINDOW SHADING DETAILS
CONDITIONED
CRAWL SPACE:SUB LEVEL:
ENTRY LEVEL:UPPER LEVEL:
TOTAL:
UN-CONDITIONED
GARAGE:BASEMENT:
ATTIC:DECK/PATIO:
TOTAL:
--1356 SF-
1356 SF
---692 SF
692 SF
No. Description Dat
-
8/3/2019 FG Construction Documents 03-026
2/13
-
8/3/2019 FG Construction Documents 03-026
3/13
-
8/3/2019 FG Construction Documents 03-026
4/13
-
8/3/2019 FG Construction Documents 03-026
5/13
-
8/3/2019 FG Construction Documents 03-026
6/13
T.O. SLAB ON GRADE EL: 0'-0"
T.O. LOW END WALL PANEL EL: 8'-2 5/8"
T.O. FOOTING EL: (-) 5'-0"
5'-0"
8'-25/8"
GROUND SLOPES AWAY FROMWALL @ 5% OR 6" PER 10'
GROUND SLOPES AWAY FROMWALL @ 5% OR 6" PER 10'
T.O. HIGH END WALL PANEL EL: 11'-4 13/16"
3'-23/16"
11'-413/16"
1
34
T&G SHIP LAP CEDAR SIDING TYP
STANDING SEAM METAL ROOFING TYP
6" STEEL LALLY COLUMN
12" THICK POURED CONC SUPPORT WALL
GLU-LAM BEAM AS REQ PER STRUCTURAL ENGINEER
POURED CONC PATIO SLAB ON GRADE
POURED CONC FOOTING BELOW FROST DEPTH
EGRESS
1
1
2
3
B.O.WINDOWH
EADER
7'-0"
B.O.WINDOWH
EADER
5'-3"
1
GROUND SLOPES AWAY FROMWALL @ 5% OR 6" PER 10'
GROUND SLOPES AWAY FROMWALL @ 5% OR 6" PER 10'
T.O. SLAB ON GRADE EL: 0'-0"
T.O. LOW END WALL PANEL EL: 8'-2 5/8"
T.O. FOOTING EL: (-) 5'-0"
5'-0"
8'-25/8"
T.O. HIGH END WALL PANEL EL: 11'-4 13/16"
3'-23/16"
11'-413/16"
2POURED CONC PATIO SLAB ON GRADE
2"/1'-0"
T&G SHIP LAP CEDAR SIDING TYP
STANDING SEAM METAL ROOFING TYP1
1
TRELLIS SHADE AWNING 4
SCALE
PROJECT NUMBER:
DATE:
DRAWN BY:CHECKED BY:
PROJECT NAME:
NOTES:
REVISION SCHEDULE:
COPYRIGHT BY HOUSEPLANS LLC ALL RIGHTS RESERVED.
FREEGREEN.com
1/4" = 1
A-01-2
ELEVATIONS
03-0
PASSIVE SHED 1
20 DECEMBER, 20
AutChec
No. Description Dat
1/4" = 1'-0"1
REAR ELEVATION
1/4" = 1'-0"2
LEFT ELEVATION
EGRESS = WINDOW WITH MINIMUM NET CLEAR OPENING OF 5.7SQUARE FEET (24"Hx20"W MIN) WINDO W SILL HEIGHTNOT MORE THAN 44" ABOVE FLOOR.
1
FACE OF GLU-LAM BEAM TO BE SEALED WITH CLEAR COATEXTERIOR GRADE VARNISH.
FOR TRELLIS SHADE AWNING DETAILS SEE PAGE "A-06-1" ITHIS SET.
2 STEPS OR RAMP TO GRADE AS REQ PER SITE CONDITIONSMINIMUM 3'-0" LANDING REQUIRED AT ALL ENTRY WAYS.PORCHES, BALCONIES OR RAISED FLOOR SURFACES LOCMORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW SHHAVE GUARDS NOT LESS THAN 36" IN HEIGHT.
FOR CONSTRUCTION ASSEMBLIES, SEE PAGE "A-00-1" INTHIS SET.
3
4
-
8/3/2019 FG Construction Documents 03-026
7/13
-
8/3/2019 FG Construction Documents 03-026
8/13
T.O. SLAB ON GRADE EL: 0'-0"
T.O. LOW END WALL PANEL EL: 8'-2 5/8"
T.O. FOOTING EL: (-) 5'-0"
5'-0"
8'
-25/8"
T.O. HIGH END WALL PANEL EL: 11'-4 13/16"
3'-23/16"
11'-413/16"
GROUND SLOPES AWAY FROMWALL @ 5% OR 6" PER 10'
STANDING SEAM METAL ROOFING TYP 1
DUCT CHASE SOFFIT FRAMED W/ 2x3
STRUCTURAL HEADERABOVE AS REQ
2x8 CANTILEVERED JOISTS
8'-0" JOIST BACKSPAN
2"/1'-0"
16" LVL OR TGI RAFTERS @24" O/COR AS REQ PER STRUCTURAL ENGINEER
NOTCH END RAFTERS
TRELLIS SHADE SCREEN3
OPTIONAL RAIN WATER HARVESTSYSTEM (DETAILED BY MANUFACTURER)
OPTIONAL SOLAR ARRAY(DETAILED BY MANUFACTURER)
2
DECK OR PATIO
SLAB ON GRADE 1
STRUCTURAL HEADERABOVE AS REQ
GUTTER AND DOWNSPOUT
7'-0
"PROVIDE SOLID BLOCKING IN
WALL FRAMING BEHIND SHELVES
1x6 T&G CLEAR CEDAR SOFFIT
NOTE:
INSULATION CONFIGURATION IN THIS WALLSECTION REFLECT THE "GOOD PERFORMANCEOPTION". SEE CONSTRUCTIONS ASSEMBLIESPAGE "A-00-1" IN THIS SET FOR COMPLETEDETAILS AND AVAILABLE OPTIONS.
1'-6"
1'-0"
1'
-6"
3'-0"
SCALE
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT NAME:
NOTES:
REVISION SCHEDULE:
COPYRIGHT BY HOUSEPLANS LLC ALL RIGHTS RESERVED.
FREEGREEN.com
1/2" = 1
A-03-1
BUILDING SECTION
03-0
PASSIVE SHED 1
20 DECEMBER, 20
AutChec
No. Description Dat
1/2" = 1'-0"1
SECTION 1
1
FOR TRELLIS SHADE AWNING DETAILS SEE PAGE "A-06-1" ITHIS SET.
2 STEPS OR RAMP TO GRADE AS REQ PER SITE CONDITIONSMINIMUM 3'-0" LANDING REQUIRED AT ALL ENTRY WAYS.PORCHES, BALCONIES OR RAISED FLOOR SURFACES LOCMORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW SHHAVE GUARDS NOT LESS THAN 36" IN HEIGHT.
FOR CONSTRUCTION ASSEMBLIES, SEE PAGE "A-00-1" INTHIS SET.
3
-
8/3/2019 FG Construction Documents 03-026
9/13
-
8/3/2019 FG Construction Documents 03-026
10/13
-
8/3/2019 FG Construction Documents 03-026
11/13
-
8/3/2019 FG Construction Documents 03-026
12/13
-
8/3/2019 FG Construction Documents 03-026
13/13
16% OFWINDOWHEIGHT
D
H
16% OFWINDOWHEIGHT
D
H
H
D
SCALE
PROJECT NUMBER:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT NAME:
ABOUT THIS PAGE:
EXTERNAL WINDOW SHADING DEVICES ARE AN EFFECTIVE METHFOR REDUCING HEAT GAINS THROUGH WINDOWS DURING SUMMIN FACT, EXTERNAL SHADING DEVICES CAN REDUCE HEAT GAINSUP TO 80% IF SIZED AND BUILT PROPERLY. WI TH THIS IN MIND,FREEGREEN HAS CREATED THIS PAGE TO ASSIST HOME BUILDERCONSTRUCTING EFFECTIVE WINDOW SHADING DEVICES. THEINFORMATION WE PROVIDE INCLUDES A ZONING MAP OF THE UNSTATES, ZONING CHARTS FOR PROPER SIZING OF SHADING DEVAND A VARIETY OF SHADING DEVICE STYLES AND MATERIALS TOSUITE DIFFERENT TASTES AND DIFFERENT HOME DESIGNS.
REVISION SCHEDULE:
COPYRIGHT BY FREEGREEN INC. ALL RIGHTS RESERVED.
OVERHANGDEPTH(ZONE4)
OVERHAN
GDEPTH(ZONE2)
OVERHAN
GDEPTH(ZONE3)
OVERHANGDEPTH(ZONE1)
OVERHANGDEPTH(ZONE5)
STEP 1: FIND YOUR ZONESTEP 2: FROM THE TABLE, DETERMINE OVERHANG DEPTH FOR YOUR WINDOWSSTEP 3: CHOOSE YOUR WINDOW SUN SHADING DEVICESTEP 4: CHOOSE YOUR MATERIALS
OVERHANG DEPTH (INCHED), D
WINDOWH
EIGHT(INCHED),H
6 12 18 24 30 36 42 48 54 60 66 72 780
6
12
18
24
30
36
42
48
54
60
66
72
78
84
90
OVERHANG DEPTH (INCHED), D
WINDOWH
EIGHT(INCHED),H
6 12 18 24 30 36 42 48 54 60 66 72 780
6
12
18
24
30
36
42
48
54
60
66
72
78
84
90
OVERHANG DEPTH (INCHED), D
WINDOWH
EIGHT(INCHED),H
6 12 18 24 30 36 42 48 54 60 66 72 780
6
12
18
24
30
36
42
48
54
60
66
72
78
84
90
OVERHANG DEPTH (INCHED), D
WINDOWH
EIGHT(INCHED),H
6 12 18 24 30 36 42 48 54 60 66 72 780
6
12
18
24
30
36
42
48
54
60
66
72
78
84
90
OVERHANG DEPTH (INCHED), D
WINDOWH
EIGHT(INCHED),H
6 12 18 24 30 36 42 48 54 60 66 72 780
6
12
18
24
30
36
42
48
54
60
66
72
78
84
90
FREEGREEN.com
1" = 1
A-06-1
WINDOW SHADINGDETAILS
03-0
PASSIVE SHED 1
20 DECEMBER, 20
Aut
Chec
MATERIAL SPECIFICATION:
WOOD TYPES:
PRES SUR E TREA TED WE STER N RE D CE DAR TROPICAL HARDWOOD (FSC CERTIFIED REQUIRED)
MAHOGANY M AS SA RA ND UB A
HARDWARE:
ALL HARDWARE MUST BE EITHER HOT DIPPED GALVANIZEDSTEEL OR STAINLESS STEEL. FREEGREEN RECOMMENDSONLY STAINLESS STEEL FOR HOUSE LOCATIONS IN CLOSEPROXIMITY TO THE OCEAN.
FINISHES:
IF USING PRESSURE TREATED WOOD SEAL & FINISH TO MATCHEXTERIOR WINDOW TRIM.
IF USING WESTERN RED CEDAR SEAL & FINISH TO MATCHEXTERIOR WINDOW TRIM
IF USING TROPICAL HARDWOOD FINISH MAY NOT BE REQUIREDSEALING AND FINISHING OF TROPICAL HARDWOODS WILLVARY BY SPECIES. CONS ULT WITH YOUR PROVIDER FORRECOMMENDED FINISHES FOR ALL TROPICAL HARDWOODPRODUCTS.
1" = 1'-0"1
BENCH WINDOW SHADING DEVICE
1" = 1'-0"2
BENCH WINDOW SHADING DEVICE
1" = 1'-0"3
BENCH WINDOW SHADING DEVICE
No. Description Dat