2

Industrial IoT devices are increasingly monitoring, controlling, and managing industrial systems, improving e!ciency and ensuring safety in operation. Prysmian Group provides optical fiber cabling solutions designed specifically for use in harsh, industrial IoT environments, such as, mining, factory automation, petrochemical, waste water, pipelines and oil & gas. These applications included conditions where cable is exposed to extreme temperatures, chemicals, and other challenging environmental elements.

Prysmian Group o"ers a complete family of outdoor, indoor & specialty fiber cables, which allows our customers to do more, make more, save more and achieve more. Cables are available with a complete line of single-mode, multimode and specialty optical fibers to fit virtually any application.

Industrial IoT | Harsh Environment Fiber Cables

Prysmian Group o!ers a full line of Industrial IoT / Harsh Environment fiber cable for applications such as:

• Chemical Processing

• Pipelines

• Oil & Gas

• Factory Automation

• Sensing

• Mines

• Airports

• Security

• Fire Resistance

• Waste Water

Our line of Industrial IoT / Harsh Environment fiber cables are designed, built and tested to withstand rugged conditions such as:

• Chemical Resistance

• High Crush Strength

• High Impact Resistance

• Extreme Temperature

• High Tensile Strength

• Fire and Heat Resistance

• Abrasion Resistance

• Oil and Gas Resistance

AIRGUARD™

Page 3: FIB-0002-0620 Industrial IoT Harsh Environment Fiber Cables … · 2020-06-03 · Airguard Harsh Environment / Petro Chemical / Factory Automation / Tray – LT XPRLTM = 2 to 288f

GenSPEED® Loose Tube | Indoor/OutdoorRiser / Plenum Rated Cables with Gel-Free Buffer Tubes

• Loose tube optical cable• Gel-free (dry) bu"er tubes• Single jacket, armored• 12 to 288 optical fibers• Available with SMF & MMF optical fibers• Flame rating: OFNR/FT4, OFNP/FT6

REFERENCE PRODUCT CODE: DRLD -RISER DPLD -PLENUM

Flame UV Tray

GenSPEED® Industrial Riser LSZH Loose Tube (dry)Indoor/Outdoor | LSZH | Tray Rated Cables

• Loose tube optical cable• Gel-free (dry)bu"er tubes• LSZH, single jacket, all-dielectric• 12 to 288 optical fibers• Available with SMF & MMF optical fibers• Flame rating: OFNR-LS/FT4 ST1• Direct Buried rated – DIR BUR• UV resistance rated – SUN RES

REFERENCE PRODUCT CODE: IRZHFlame Low

Smoke Chemical UV Zero Halogen

Low TempTray

Lifeline® Specialty: Fire Resistant QFCI Cable Fire Resistant, Flame Retardant Halogen-Free Loose Tube | UL Riser Rated

• Loose tube optical cable• Gel filled bu"er tubes• Indoor/Outdoor• Fire resistant• LSZH Jacket• 2 to 48 optical fibers• Available with SMF and MMF optical fibers• Flame Rating: OFCR/FT4

REFERENCE PRODUCT CODE: QFCIFire Flame Low

Smoke Tray UV Zero Halogen

- Loose tube optical cable- Gel-free (dry) bu"er tubes- ezINTERLOCK armor- 12 to 288 optical fibers- Available with SMF & MMF optical fibers- Flame rating: OFCR/FT4, OFCP/FT6

REFERENCE PRODUCT CODE: DRLDBAJ -RISER DPLDBAJ -PLENUM

GenSPEED® Interlock Indoor/Outdoor Loose TubeRiser / Plenum Rated Cables

Flame UV Tray

AIRGUARD™ XP - Chemical Resistant | High Crush | Low-TempPetrochemical | Utility | Waste Water | Tray Rated

• Loose tube optical cable• Gel filled bu"er tubes• Chemical resistant• 12 to 288 optical fibers• Double or single jacket, all-dielectric, armored• Available with SMF & MMF optical fibers• Flame rating: OFNG-LS/FT4 ST1• UL 2556 4.2.8.3 “oil resistance” PRII• UL 2556 4.2.8.4 “gasoline resistance” GRII• Direct Buried rated – DIR BUR• UV resistance rated – SUN RES

REFERENCE PRODUCT CODE: XRPLTMFlame Low

Smoke Chemical Oil Gasoline Tray Crush Tensile UVLow Temp

3

Page 4: FIB-0002-0620 Industrial IoT Harsh Environment Fiber Cables … · 2020-06-03 · Airguard Harsh Environment / Petro Chemical / Factory Automation / Tray – LT XPRLTM = 2 to 288f

+1-800-879-9862 | +1-800-669-0808 na.prysmiangroup.com/telecom

4

GenSPEED® Indoor/Outdoor Tight BufferedRiser and Plenum Cables

• Indoor/outdoor• Tight bu"er distribution• 900µm tight bu"er fibers• Riser: 2 to 144 fiber count• Plenum: 2 to 96 fiber count• Available with SMF & MMF optical fibers• Flame rating: OFNR/FT4 & OFNP/FT6

REFERENCE PRODUCT CODE: C1181 -RISER C1182 -PLENUM

Flame UV

Flame UV

GenSPEED® Indoor/Outdoor LSZH TBLow-Smoke Zero-Halogen Cables

• Indoor/outdoor• Tight bu"er distribution• 900µm tight bu"er fibers• Riser: 2 to 24 fiber count• LSZH Jacket• Available with SMF & MMF optical fibers• Flame rating: OFNR/FT4

REFERENCE PRODUCT CODE: 700

GenSPEED® Interlock Indoor/Outdoor Tight BufferedRiser and Plenum Rated Cables

Flame UV

• Indoor/outdoor• Tight bu"er distribution• 900µm tight bu"er fibers • Aluminum or steel interlocking armor• Riser: 2 to 144 fiber count• Plenum: 2 to 96 fiber count• Available with SMF & MMF optical fibers• Flame rating: OFCR/FT4 & OFCP/FT6

REFERENCE PRODUCT CODE: C1181AJ -RISER C1182AJ -PLENUM

GenSPEED® Indoor/Outdoor Loose Tube Mining CableMSHA and Tray Cables

Flame Tray Crush Tensile

• Loose tube optical cable• Gel filled bu"er tubes• Chemical resistant, double jacket, all-dielectric• 2 to 144 optical fibers• Available with SMF & MMF optical fibers• Flame rating: OFNR/FT4• MSHA & Pennsylvania Bureau of Deep Mine Safety

REFERENCE PRODUCT CODE: RLTM

DFS™ Sensing Cable with OptiStrain™ ModulesOutdoor Sensing Cable

• Loose tube optical cable• 1 to 5 loose fiber bu"er tubes for temperature

sensing and/or Communications• Gel-free (dry) or gel-filled bu"er tubes • 2 to 4 simplex tight bu"er units for strain

sensing• Single jacket, armored

REFERENCE PRODUCT CODE: EDS (gel-free) ETS (gel-filled)

UV Sensing

Page 5: FIB-0002-0620 Industrial IoT Harsh Environment Fiber Cables … · 2020-06-03 · Airguard Harsh Environment / Petro Chemical / Factory Automation / Tray – LT XPRLTM = 2 to 288f

Airguard™XP -Oil andGas UtilityLow-TempHigh Crush

Lifeline® Fire

Resistant QFCI Cable

GenSPEED® Industrial

RiserLSZH Dry

Loose Tube

GenSPEED®

Indoor/Out-door Loose

Tube

GenSPEED® Dry

Indoor/Outdoor

Loose Tube

ExpressLT™All-Dielectric

Armored(gel or dry) Loose Tube

GenSPEED®

Riser Indoor/Outdoor

Tight Buffered

GenSPEED® Plenum

Indoor/OutdoorTight Buffered

GenSPEED®

Riser LSZH Indoor/Outdoor

Tight Buffered

Mining Indoor/Outdoor

Riser Loose Tube

Outdoor FAA All-

DielectricLoose Tube

Product Family --> Airguard XP QFCI IRZHx DRLxx DPLDB EDHDA2JKT ETHDA2JKT C1181 C1182 700 RLTM FAA

Application Low-Temp, High Crush

Fire Resistance LSZH

General Application

Riser

General Application

Plenum

OSP All-Dielectric

Rodent Resistant

General Application

RiserGeneral Application

PlenumGeneral Application

LSZH Riser Mining Airports

Cable TypeIndoor/ Outdoor

Loose Tube

Indoor/ Outdoor

Loose Tube

Indoor/ Outdoor

Loose Tube

Indoor/ Outdoor

Loose Tube

Indoor/ Outdoor

Loose Tube

Outdoor Loose Tube

Indoor/ Outdoor Tight

Bu"er

Indoor/ Outdoor Tight

Bu"er

Indoor/ Outdoor Tight

Bu"er

Indoor/ Outdoor

Loose Tube

Outdoor Loose Tube

Gel Filled Tube yes yes no yes no no n/a n/a n/a yes yes

Fiber Count 2 to 288 2 to 48 2 to 288 2 to 132 2 to 144 4 to 432 2 to 144 2 to 96 2 to 24 2 to 144 2 to 60

Qualified Fibers ALL SM, 62.5, 50 OM2 ALL ALL ALL ALL ALL ALL ALL ALL ALL

Corrugated Steel Tape Option no no yes (PSP) yes

(PSP) no no no no no no no

Interlock Armor no no yes yes yes yes yes yes yes no no

Steel Wire Braiding no yes no no no no no no no no no

Flame Rating OFNG-LSFT4 ST1

OFCRFT4 ST1

OFR-LS FT4 ST1

OFNR FT4

OFNP FT6 none OFNR

FT4OFNP FT6

OFNR FT4

OFNR FT4 none

MSHA Listing no no no no no no no no no yes no

Low Smoke yes yes yes no yes no no yes yes no no

Zero Halogen no yes yes no no no no no yes no no

Recommended for Tray Usage yes yes yes no no no no no no yes no

Installation Tensile Load (N) 4500 1500 2670

to 4500 2700 2700 4500 445 to 2670

445 to 2670

660 to 1320 4500 2700

High Compressive Resistant yes no no no no yes no no no yes no

Low Temperature Mechanicals yes no no no no no no no no no no

Operating Temperature

-50°C to +70°C

-30°C to +60°C

-50°C to +70°C

-50°C to +70°C

-40°C to +70°C

-40°C to +70°C

-40°C to+80°C

-40°C to+80°C

-40°C to+80°C

-50°C to +70°C

-40°C to +70°C

Installation Temperature

-30°C to +60°C

-10°C to +60°C

-30°C to +60°C

-10°C to +60°C

0°C to +60°C

-30°C to +60°C

-10°C to+60°C

0°C to+60°C

-10°C to+50°C

-10°C to +60°C

-30°C to +60°C

UV Resistant Jacket yes yes yes yes yes yes yes yes yes yes yes

Chemical Resistance (Scale: 1 to 4) 4 being the best 3 2 2 1 4 1 1 3 2 1 4

Oil and Gas Resistance (Scale: 1 to 4) 4 being the best

4 2 2 1 4 1 1 4 2 2 4

*outer jacket type is fiber count specific

FLAME RATING TERMS: OFN = Optical Fiber Non-conductive OFNG = Optical Fiber Non-conductive General Purpose OFNR FT4 = Optical Fiber Non-conductive riser - USA & Canada OFNP FT6 = Optical Fiber Non-conductive Plenum - USA & Canada LS ST1 = Low Smoke - USA & Canada * Optical cables become conductive with metalic armoring wherein the “N” (non-conductive) term converts to a “C” (conductive) when metalic armor is applied. ie: OFNR vs OFCR

Product Selection Chart

5

Page 6: FIB-0002-0620 Industrial IoT Harsh Environment Fiber Cables … · 2020-06-03 · Airguard Harsh Environment / Petro Chemical / Factory Automation / Tray – LT XPRLTM = 2 to 288f

6

ORDERING GUIDE - SPECIALTYThe Prysmian Group part number incorporates several significant attributes involving cable design and optical performance.The appropriate part number can be configured using the process described below:

PART NUMBER CONTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

REFER to SPECIALTY PRODUCTS TABLE

3 CONTRUCTION

INTERLOCK ARMOR (optional)

(blank) = none

AJ = Jacketed Aluminum

SJ = Jacketed Steel

AB = Bare Aluminum

SB = Bare Steel

4 FIBER GROUPING

00 = no grouping | Central LT

06 = 6f per unit or tube

12 = 12f per unit or tube

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE (LT)

Wavelength: 1310/1383/1550 nm | Attenuation: 0.4/0.4/0.3 dB/km

HB = Single-Mode (ITU G.652 D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 D)

CE = Corning™ Single-Mode (ITU G.652 D Compliant)

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

BX = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)

MULTIMODE Wavelength(mm)

Bandwidth(MHz)

1 GbEDist (m)

10 GbEDist (m)

G6 = OM1 (62.5µm) 850/1300 200/500 300/550 33/___

G5 = OM2+ BIF (50µm) 850/1300 700/500 800/550 150/___

G3 = OM3 BIF (50µm) 850/1300 1500/500 1000/550 300/___

G4 = OM4 BIF (50µm) 850/1300 3500/500 1100/550 550/___

6 FIBER COUNT

002 TO 288 fibers

7 FIBER GRADESINGLE-MODE | Loose Tube (LT) MULTIMODE

Attenuation (dB/km) Wavelength (nm) Fiber Type Attenuation (dB/km) Wavelength (nm) Type

E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, CE, B1, B2, or BX M2 = 3.5/1.0 dB/km 850/1300 OM1 (62.5µm)

E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, CE, B1, B2, or BX M3 = 3.0/1.0 dB/km 850/1300 OM2+, OM3, OM4 (50µm)

SINGLE-MODE | Tight Buffer (TB) Other cable constructions and fiber performance grades available.Attenuation (dB/km) Wavelength (nm) Fiber Type

EB = 0.70/0.70/0.70 1310/1383/1550 HB, ES, CE, B1, B2, or BX

Example: AirGuard™ XP , 12 fibers per tube with 72 single-mode fibers 0.4/0.4/0.3 dB/km @ 1310/1383/1550.

1 LENGTHMARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE

F - XPRLTM - 12 - HB - 072 - E1

Page 7: FIB-0002-0620 Industrial IoT Harsh Environment Fiber Cables … · 2020-06-03 · Airguard Harsh Environment / Petro Chemical / Factory Automation / Tray – LT XPRLTM = 2 to 288f

7

2 PRODUCT FAMILY

LOOSE TUBE InterLock Flame RatingAirguard Harsh Environment / Petro Chemical / Factory Automation / Tray – LT

XPRLTM = 2 to 288f Oil & Gas, Harsh, Low Temp Cable, Tray, 2 Jackets N OFNG-LS/FT4 ST1

XPRLTMB = 2 to 216f I/O Harsh,1 Jackets N OFN

XPRLTMD = 2 to 216f I/O Harsh, Armored, 2 Jackets N OFC

Mining

RLTM = 2 to 144f MINEnet. I/O Riser, 2 Jacket N OFNR/FT4

Industrial / Low Smoke Zero Halogen (LSZH) / Factory Automation / Tray – LT

IRZHB = 2 to 288f GenSPEED® Indust. Riser, All-Dieletric, Tray, 1 Jacket Y OFNR-LS/FT4

IRZHC = 2 to 288f GenSPEED® Indust. Riser, All-Dieletric, Tray, 2 Jackets N OFNR-LS/FT4

IRZHD = 2 to 288f GenSPEED® Indust. Riser, Tray, Armored, 2 Jackets N OFNR-LS/FT4

Airport Cable (FAA) - LT

FAACF = 2 to 60f GenSPEED® Loose Tube, All-Dieletric, 2 Jackets N N/A

Heavy Duty – Harsh Environment / Tray / Factory Automation / Interconnect

MDU829 = 1f GenSPEED® Indoor 2.9mm Dropd N OFNR/FT4

MDU548 = 1f GenSPEED® Indoor, 4.8mm Drop N OFNR/FT4

MDU548BK = 1f GenSPEED® I/O 4.8mm Drop N OFNR/FT4

Note: See the data sheet since a di"erent part number configuration is used.

Page 8: FIB-0002-0620 Industrial IoT Harsh Environment Fiber Cables … · 2020-06-03 · Airguard Harsh Environment / Petro Chemical / Factory Automation / Tray – LT XPRLTM = 2 to 288f

Follow us:

PRYSMIAN GROUP4 Tesseneer Drive, Highland Heights, KY 41076+1-859-572-8000 / na.prysmiangroup.comFIB-0002-0620

Prysmian Group, is the corporate brand which includes the three distinct commercial brands of Prysmian, Draka and General Cable – is a world leader in the energy and telecom cable systems industry. With over 140 years of experience, sales of over #11 billion, 29,000 employees in over 50 countries and 112 plants, the Group is strongly positioned in high-tech markets and o"ers the widest possible range of products, services, technologies and know-how.