figure g3 caryville - florida · 225840 flatpack2 fp2-48/150a 2b 4l lvbd 2ac 1 502666 100a battery...

33
Figure G3 Caryville Battery Plant G:\FDOTGC\Battery Replacement\I-10 Replacement 2013\Appendix\FigG3_Caryville_BatteryPlant.vsd 03/12/13 Vendor Shall install new battery in existing rack. Page G6 of 6 64

Upload: others

Post on 24-Mar-2020

15 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

Figure G3Caryville

Battery PlantG:\FDOTGC\Battery Replacement\I-10 Replacement 2013\Appendix\FigG3_Caryville_BatteryPlant.vsd

03/12/13

Vendor Shall install new battery in existing rack.

Page G6 of 6 64

Page 2: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

FLORIDA DEPARTMENT OF TRANSPORTATION

I-10 BATTERY PLANT REPLACEMENT

Appendix H – Chipley DOT

65

Page 3: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

FLORIDA DEPARTMENT OF TRANSPORTATION

I-10 BATTERY PLANT REPLACEMENT

Page H2 of 7

Appendix H – Table of Contents – Figures and Drawings

Figure H1 – Chipley DOT Shelter Floor Plan ............................................................ H4 of 7

Figure H2 – Chipley DOT -48VDC Power Distribution Rack Profile .......................... H5 of 7

Figure H3 – Chipley DOT West Interior Wall ............................................................ H6 of 7

Figure H4 – Chipley DOT Battery Plant Photo.......................................................... H7 of 7

66

Page 4: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

FLORIDA DEPARTMENT OF TRANSPORTATION

I-10 BATTERY PLANT REPLACEMENT

Page H3 of 7

Chipley DOT Site Requirements

The Vendor shall furnish and install the following equipment at the Chipley DOT site located at 1074 US-90, Chipley, FL.

A. One Exide Absolyte GP series battery plant model number M87-024-05009-R19ACLV shall

be installed in accordance with this Appendix and Section 2.2 of this Scope of Services.

The new battery plant shall be installed in the same location as the removed battery plant.

The Vendor shall replace the existing cable with 1/0 AWG stranded. Red jacketed cable

shall be used for -48 VDC connections and black jacketed cable shall be used for the return.

B. The Generex BACS battery management system shall be installed in accordance with this

Appendix and Section 2.3 of this Scope of Services. The DIN Rail, Webmanager, DC/DC

Converter, and SPDs shall be mounted on the West Interior Wall in accordance with this

Appendix. The DIN rail shall be installed no more than 10” away from the ground halo at the

shelter and shall be grounded in accordance with manufacturer’s recommendations.

IP Address: 172.16.4.22

Subnet Mask: 255.255.254.0

Gateway: 172.16.4.19

TABLE H1 – MAJOR EQUIPMENT LIST

Model Number Description QTY.

M87-024-05009-R19ACLV Exide Battery 19" rack mount 1

AMGBACS 1001 24-2V Master Kit

Generex BACS management system including webmanager, C40 modules with temperature sensor, measuring cables, and bus cables

1

TCL 024-112DC TracoPower DC/DC Converter 1

DR21649 Atlantic Scientific 17.5” DIN Rail 1

ZB24540 Atlantic Scientific Ethernet SPD 2

67

Page 5: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

G:\FDOTGC\Battery Replacement\I-10 Replacement 2013\Appendix A\FigH1_ChipleyDOT_ShelterFloorPlan_20050401.vsd07/19/13

Scale: 1/2" = 1'-0"

Woo

den

She

lfw

/ Dra

wer

MAS Call Box Base Station Rack (FR1)

-48 VDCPower

Distribution Rack

Channel Bank Rack (FR6)

ASN / DACCRack (FR5)

DVM6-45MW TerminalRack (FR2)

DVM6-45MW TerminalRack (FR3)

FDOT 47 MHzGE MASTRIIBase Station

Passport 15000Rack (FR4)

Page H4 of 7

BPS 2000 Location

68

Page 6: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

Figure H2Chipley DOT (3-3428)

-48 VDC Power Distribution RackG:\FDOTGC\Battery Replacement\I-10 Replacement 2013\Appendix A\FigH2_ChipleyDOT_-48VDCPowerDistributionRack_20051231.vsd

04/12/13

Empty

TWINPACKPLUS

25A

TWINPACKPLUS

25A

Scale: 1 1/4" = 1'-0"

1 2 9 10

4 3 8 11

5 6 7 12

20 19 18 13

21 22 17 14

24 23 16 15

Page H5 of 7

+

-

69

Page 7: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

C:\Users\danielle morales.RCC-SEREGION\Desktop\I-10 Replacement 2013\Appendix A\FigH3_ChipleyDOT_InteriorWestWall_20050401.vsd04/15/13

Figure H3Chipley DOT (3-3428)

Interior West Wall

Scale: 1/2" = 1'-0"

Main Braker Panel2 of 2

VoIP

Main Braker Panel1 of 2

Alarm66 Block

BACS

WebManager

DC/DC

Converter

Ethernet

SPD

Page H6 of 7 70

Page 8: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

Figure H4Chipley DOTBattery Plant

G:\FDOTGC\Battery Replacement\I-10 Replacement 2013\Appendix A\FigH4_Chipley_BatteryPlant.vsd04/12/13

Vendor Shall install new battery in existing rack.

Page H7 of 7 71

Page 9: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

FLORIDA DEPARTMENT OF TRANSPORTATION

I-10 BATTERY PLANT REPLACEMENT

Appendix I – Marianna FHP

72

Page 10: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

FLORIDA DEPARTMENT OF TRANSPORTATION

I-10 BATTERY PLANT REPLACEMENT

Page I2 of 7

Appendix I – Table of Contents – Figures and Drawings

Figure I1 – Marianna FHP Shelter Floor Plan ........................................................... I5 of 7

Figure I2 – Marianna FHP -48VDC Power Distribution Rack Profile ......................... I6 of 7

Figure I3 – Marianna FHP Battery Plant Photo......................................................... I7 of 7

73

Page 11: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

FLORIDA DEPARTMENT OF TRANSPORTATION

I-10 BATTERY PLANT REPLACEMENT

Page I3 of 7

Marianna FHP Site Requirements

The Vendor shall furnish and install the following equipment at the Marianna FHP site located at 3613 US-90, Marianna, FL.

A. One Exide Absolyte GP series battery plant model number M87-024-05005-R19AALV shall

be installed in accordance with this Appendix and Section 2.2 of this Scope of Services.

The new battery plant shall be installed in the same location as the removed battery plant.

The Vendor shall replace the existing cable with 1/0 AWG stranded. Red jacketed cable

shall be used for -48 VDC connections and black jacketed cable shall be used for the return.

B. The Generex BACS battery management system shall be installed in accordance with this

Appendix and Section 2.3 of this Scope of Services.

IP Address: 172.16.76.22

Subnet Mask: 255.255.254.0

Gateway: 172.16.76.19

C. One Eltek Flatpack2 Rectifier System shall be installed in accordance with this Appendix

and Section 2.4 of this Scope of Services. The new rectifier system shall be installed in the

same location as the removed rectifier system. The two rectifiers shall be wired to separate

20A double pole Square D circuit breakers appropriate for the Square D model

QO140L200G load center. The main load center circuit breakers shall be furnished and

installed by the Vendor. All wiring shall be new and installed. Conduit may be reused.

IP Address: 172.16.76.20

Subnet Mask: 255.255.254.0

Gateway: 172.16.76.19

74

Page 12: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

FLORIDA DEPARTMENT OF TRANSPORTATION

I-10 BATTERY PLANT REPLACEMENT

Page I4 of 7

TABLE I1 – MAJOR EQUIPMENT LIST

Model Number Description QTY.

M87-024-05005-R19AALV Exide Battery 19" rack mount 1

AMGBACS 1001 24-2V Master Kit

Generex BACS management system including webmanager, C40 modules with temperature sensor, measuring cables, and bus cables

1

TCL 024-112DC TracoPower DC/DC Converter 1

DR 24500 Atlantic Scientific DIN Rail to Mount BACS Webmanager

1

Q4820N-F19DB01-VC Integrated Power System 1

225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC

1

502666 100A Battery Disconnect breaker 1

502658 35A Circuit breaker 1

241115.105 Flatpack2 Rectifier 2

236408 Flatpack2 Blind Panels 2

507173 LUG, #1AWG, 2 hole 2

LG1D2A8A110 LUG,DH, 5/8" SP,1/4 STUD, 2/0AWG 2

ZB24540 Atlantic Scientific Ethernet SPD 4

75

Page 13: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

Forestry Base

StationCB + NMS Rack ER-6

47 MHz Repeater

47 MHz Base Station

DVM6-45 MW

Repeater Rack ER-2

MACBS ER-1

G:\FDOTGC\Battery Replacement\I-10 Replacement 2013\Appendix A\FigI1_MariannaFHP_ShelterFloorPlan_20110524.vsd07/19/13

Scale: 3/8" = 1'-0"

-48V DCBattery Plant

Duplexer

Page I5 of 7

BPS 2000 Location

76

Page 14: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

Scale: 1 1/4" = 1'-0"

Figure I2Marianna FHP

-48VDC Power Distribution RackG:\FDOTGC\Battery Replacement\I-10 Replacement 2013\Appendix A\FigI2_MariannaFHP-PwrPlantRack_20130724.vsd

07/24/13

Absolyte Battery Bank

Absolyte Battery Bank

Absolyte Battery Bank

Absolyte Battery Bank81 9 16 17 24

72 10 15 18 23

63 11 14 19 22

54 12 13 20 21

+-

Page I6 of 7

BACS

WebManager

DC/DC Converter

PCP -48 VDC Power Systems

2 RU Panel

Smart Pack BATT LOAD

Flatpack2

Rectifier System

77

Page 15: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

Figure I3Marianna FHPBattery Plant

G:\FDOTGC\Battery Replacement\I-10 Replacement 2013\Appendix A\FigI3_Marianna_BatteryPlant.vsd04/12/13

Vendor Shall install new battery in existing rack.

Page I7 of 7 78

Page 16: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

FLORIDA DEPARTMENT OF TRANSPORTATION

I-10 BATTERY PLANT REPLACEMENT

Appendix J – Sneads Weigh Station

79

Page 17: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

FLORIDA DEPARTMENT OF TRANSPORTATION

I-10 BATTERY PLANT REPLACEMENT

Page J2 of 6

Appendix J – Table of Contents – Figures and Drawings

Figure J1 – Sneads Weigh Station Shelter Floor Plan .............................................. J4 of 6

Figure J2 – Sneads Weigh Station -48VDC Power Distribution Rack Profile ............ J5 of 6

Figure J3 – Sneads Weigh Station Battery Plant Photo ............................................ J6 of 6

80

Page 18: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

FLORIDA DEPARTMENT OF TRANSPORTATION

I-10 BATTERY PLANT REPLACEMENT

Page J3 of 6

Sneads Weigh Station Site Requirements

The Vendor shall furnish and install the following equipment at the Sneads Weigh Station site located 2 miles west of SR-286 and I-10 at East Bound side of weigh station.

A. One Exide Absolyte GP series battery plant model number M87-024-05005-R19AALV shall

be installed in accordance with this Appendix and Section 2.2 of this Scope of Services.

The new battery plant shall be installed in the same location as the removed battery plant.

The Vendor shall replace the existing cable with 1/0 AWG stranded. Red jacketed cable

shall be used for -48 VDC connections and black jacketed cable shall be used for the return.

B. The Generex BACS battery management system shall be installed in accordance with this

Appendix and Section 2.3 of this Scope of Services.

IP Address: 172.16.74.22

Subnet Mask: 255.255.254.0

Gateway: 172.16.74.19

TABLE J1 – MAJOR EQUIPMENT LIST

Model Number Description QTY.

M87-024-05005-R19AALV Exide Battery 19" rack mount 1

AMGBACS 1001 24-2V Master Kit

Generex BACS management system including webmanager, C40 modules with temperature sensor, measuring cables, and bus cables

1

TCL 024-112DC TracoPower DC/DC Converter 1

DR 24500 Atlantic Scientific DIN Rail to Mount BACS Webmanager

1

ZB24540 Atlantic Scientific Ethernet SPD 2

81

Page 19: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

G:\FDOTGC\Battery Replacement\I-10 Replacement 2013\Appendix A\FigJ1_Sneads-FloorPlanShelter-20061102.vsd

07/19/13

Scale: 1/2" = 1'-0"

-48 VDCDistribution

Rack

Channel Bank Rack QR-6

DVM6-45 MW Repeater

Rack QR-5

Page J4 of 6

BPS 2000 Location

82

Page 20: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

Figure J2

Sneads Weigh Station (3-3510)

-48 VDC Power Distribution RackG:\FDOTGC\Battery Replacement\I-10 Replacement 2013\Appendix A\FigJ2_SneadsWeighStation_-48VDCPowerDistributionRack.vsd

04/12/13

EMPTY EMPTYTWINPACKPLUS

COVER PLATE

HI/LO DC ALARM PANEL

SSD2 PANEL

NAME TAG

COVER PLATE

CONNECTOR PLATE(CONNECTS ON BACK)

COVER PLATE

DIGITAL EQUALIZER

Scale: 1 1/4" = 1'-0"

BREAKER PANEL

Absolyte Battery Bank

Absolyte Battery Bank

Absolyte Battery Bank

Absolyte Battery Bank81 9 16 17 24

72 10 15 18 23

63 11 14 19 22

54 12 13 20 21

+-

Page J5 of 6

BACS

WebManager

DC/DC Converter

83

Page 21: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

Figure J3Sneads Weigh Station

Battery PlantG:\FDOTGC\Battery Replacement\I-10 Replacement 2013\Appendix\FigJ3_SneadsWeighStation_BatteryPlant.vsd

03/12/13

Vendor Shall install new battery in existing rack.

Page J6 of 6 84

Page 22: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

FLORIDA DEPARTMENT OF TRANSPORTATION

I-10 BATTERY PLANT REPLACEMENT

Appendix K – Aspalaga

85

Page 23: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

FLORIDA DEPARTMENT OF TRANSPORTATION

I-10 BATTERY PLANT REPLACEMENT

Page K2 of 6

Appendix K – Table of Contents – Figures and Drawings

Figure K1 – Aspalaga Shelter Floor Plan ................................................................. K4 of 6

Figure K2 – Aspalaga -48VDC Power Distribution Rack Profile ............................... K5 of 6

Figure K3 – Aspalaga Battery Plant Photo ............................................................... K6 of 6

86

Page 24: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

FLORIDA DEPARTMENT OF TRANSPORTATION

I-10 BATTERY PLANT REPLACEMENT

Page K3 of 6

Aspalaga Site Requirements

The Vendor shall furnish and install the following equipment at the Aspalaga site located 3.5 miles east of SR-286 and I-10 interchange at rest area (off east-bound on-ramp), Aspalaga, FL.

A. One Exide Absolyte GP series battery plant model number M87-024-05005-R19AALV shall

be installed in accordance with this Appendix and Section 2.2 of this Scope of Services.

The new battery plant shall be installed in the same location as the removed battery plant.

The Vendor shall replace the existing cable with 1/0 AWG stranded. Red jacketed cable

shall be used for -48 VDC connections and black jacketed cable shall be used for the return.

B. The Generex BACS battery management system shall be installed in accordance with this

Appendix and Section 2.3 of this Scope of Services.

IP Address: 172.16.72.22

Subnet Mask: 255.255.254.0

Gateway: 172.16.72.19

TABLE K1 – MAJOR EQUIPMENT LIST

Model Number Description QTY.

M87-024-05005-R19AALV Exide Battery 19" rack mount 1

AMGBACS 1001 24-2V Master Kit

Generex BACS management system including webmanager, C40 modules with temperature sensor, measuring cables, and bus cables

1

TCL 024-112DC TracoPower DC/DC Converter 1

DR 24500 Atlantic Scientific DIN Rail to Mount BACS Webmanager

1

ZB24540 Atlantic Scientific Ethernet SPD 2

87

Page 25: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

CB/NMSRack

-48 VDCDistribution

Rack

MACBSEAST RACK

DVM6-45REPEATER

RACK

MACBSWESTRACK

BO

OK

CA

SE

+

+

+

Figure K1Aspalaga

Shelter Floor Plan

G:\FDOTGC\Battery Replacement\I-10 Replacement 2013\Appendix A\FigK1_Aspalaga_ShelterFloorPlan_20111228.vsd07/19/13

Page K4 of 6

BPS 2000 Location

88

Page 26: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

Figure K2

Aspalaga (3-3426)

-48 VDC Power Distribution RackG:\FDOTGC\Battery Replacement\I-10 Replacement 2013\Appendix A\FigK2_Aspalaga_-48VDCPowerDistributionRack_20061002.vsd

04/12/13

Empty

TWIN

PACK

PLUS

25A

TWIN

PACK

PLUS

25A

Scale: 1 1/4" = 1'-0"

Absolyte Battery Bank

Absolyte Battery Bank

Absolyte Battery Bank

Absolyte Battery Bank81 9 16 17 24

72 10 15 18 23

63 11 14 19 22

54 12 13 20 21

+-

Page K5 of 6

BACS

WebManager

DC/DC Converter

89

Page 27: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

Figure K3Aspalaga

Battery PlantG:\FDOTGC\Battery Replacement\I-10 Replacement 2013\Appendix\FigK3_Aspalaga_BatteryPlant.vsd

03/12/13

Vendor Shall install new battery in

existing rack.

Page K6 of 6 90

Page 28: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

FLORIDA DEPARTMENT OF TRANSPORTATION

I-10 BATTERY PLANT REPLACEMENT

Appendix L – Quincy FHP

91

Page 29: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

FLORIDA DEPARTMENT OF TRANSPORTATION

I-10 BATTERY PLANT REPLACEMENT

Page L2 of 7

Appendix L – Table of Contents – Figures and Drawings

Figure L1 – Quincy FHP Shelter Floor Plan ............................................................. L5 of 7

Figure L2 – Quincy FHP -48VDC Power Distribution Rack Profile............................ L6 of 7

Figure L3 – Quincy FHP Battery Plant Photo ........................................................... L7 of 7

92

Page 30: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

FLORIDA DEPARTMENT OF TRANSPORTATION

I-10 BATTERY PLANT REPLACEMENT

Page L3 of 7

Quincy FHP Site Requirements

The Vendor shall furnish and install the following equipment at the Quincy FHP site located at 18290 US-90, Quincy, FL.

A. One Exide Absolyte GP series battery plant model number M87-024-05005-R19AALV shall

be installed in accordance with this Appendix and Section 2.2 of this Scope of Services.

The new battery plant shall be installed in the same location as the removed battery plant.

The Vendor shall replace the existing cable with 1/0 AWG stranded. Red jacketed cable

shall be used for -48 VDC connections and black jacketed cable shall be used for the return.

B. The Generex BACS battery management system shall be installed in accordance with this

Appendix and Section 2.3 of this Scope of Services.

IP Address: 172.16.70.22

Subnet Mask: 255.255.254.0

Gateway: 172.16.70.19

C. One Eltek Flatpack2 Rectifier System shall be installed in accordance with this Appendix

and Section 2.4 of this Scope of Services. The new distribution center shall be installed in

the same location as the removed distribution center. The two rectifiers shall be wired to

separate 20A double pole Square D circuit breakers appropriate for the Square D model

QO140L200G load center. The main load center circuit breakers shall be furnished and

installed by the Vendor. All wiring shall be new and installed. Conduit may be reused.

IP Address: 172.16.70.20

Subnet Mask: 255.255.254.0

Gateway: 172.16.70.19

93

Page 31: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

FLORIDA DEPARTMENT OF TRANSPORTATION

I-10 BATTERY PLANT REPLACEMENT

Page L4 of 7

TABLE L1 – MAJOR EQUIPMENT LIST

Model Number Description QTY.

M87-024-05005-R19AALV Exide Battery 19" rack mount 1

AMGBACS 1001 24-2V Master Kit

Generex BACS management system including webmanager, C40 modules with temperature sensor, measuring cables, and bus cables

1

TCL 024-112DC TracoPower DC/DC Converter 1

DR 24500 Atlantic Scientific DIN Rail to Mount BACS Webmanager

1

Q4820N-F19DB01-VC Integrated Power System 1

225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC

1

502666 100A Battery Disconnect breaker 1

502658 35A Circuit breaker 1

241115.105 Flatpack2 Rectifier 2

236408 Flatpack2 Blind Panels 2

507173 LUG, #1AWG, 2 hole 2

LG1D2A8A110 LUG,DH, 5/8" SP,1/4 STUD, 2/0AWG 2

ZB24540 Atlantic Scientific Ethernet SPD 4

94

Page 32: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

48V DCDistribution

Rack

DOF159 MHz

Base Station

Channel Bank

Rack CR-5

FHPFilter

Duplexer

FHP Tx/Rx #1Motorola

FHP Tx/Rx #2Motorola

DVM6-45 MW

Repeater Rack CR-2

MAS Call Box Base Station

Rack CR-1

G:\FDOTGC\Battery Replacement\I-10 Replacement 2013\Appendix A\FigL1_QuincyFHP_ShelterFloorPlan_20040422.vsd07/19/13

Figure L1Quincy FHP (3-3425)

Shelter Floor Plan

Scale: 3/8" = 1'-0"

RWIS Rack

Page L5 of 7

BPS 2000 Location

95

Page 33: Figure G3 Caryville - Florida · 225840 Flatpack2 FP2-48/150A 2B 4L LVBD 2AC 1 502666 100A Battery Disconnect breaker 1 502658 35A Circuit breaker 1 241115.105 Flatpack2 Rectifier

Scale: 1 1/4" = 1'-0"

Figure L2Quincy FHP

-48VDC Power Distribution RackG:\FDOTGC\Battery Replacement\I-10 Replacement 2013\Appendix A\FigL2_QuincyFHP-PwrPlantRack_20130723.vsd

07/24/13

Absolyte Battery Bank

Absolyte Battery Bank

Absolyte Battery Bank

Absolyte Battery Bank81 9 16 17 24

72 10 15 18 23

63 11 14 19 22

54 12 13 20 21

+-

Page L6 of 7

BACS

WebManager

DC/DC Converter

PCP -48 VDC Power Systems

2 RU Panel

Smart Pack BATT LOAD

Flatpack2

Rectifier System

96