MOTTCORP.COM | 860-747-6333 | 84 SPRING LANE | FARMINGTON CT 06032 | ISO 9001 CERTIFIED 0118 REV Filter testing designed to assess your unique conditions To Optimize Your Filtration Process, Mott Will: Replicate or closely correlate your process conditions in our lab center Test various Mott filter media options under your conditions Provide you with a comprehensive performance report of Mott filtration technology in your process Make recommendations on media selection and filter design to optimize your manufacturing process Get the Data You Need Particle Size Distribution (PSD) Feeds Solids Concentration Catalyst Recovery/Removal Rates Feed Viscosity Filtrate Clarity - PPM or Turbidity (NTU) Solids Cake Characteristics Flux Rates Pressure Drop Analysis Backwash Characterization Backpulse Characterization FILTER FEASIBILITY TESTING Rely on our Experience for Optimal Filtration Solutions Take advantage of Mott Corporation’s fully equipped filtration testing laboratory to determine the optimal process operating parameters and filter design for your unique application. Testing is available for applications involving both liquid/solids and gas/solids. Though applications may appear similar, slight differences, including operating temperature, solids content, particle size and distribution of solids, can significantly impact downstream product quality. Using our lab’s highly advanced diagnostic equipment, our experienced engineers will provide you with a comprehensive, in-depth application analysis report and process operating parameter recommendations, including initial filter design recommendations. We will return any remaining unfiltered feed, collected solids and liquid filtrate samples to you for further analysis and/or disposal. Available Equipment Horiba Particle Size Distribution Analyzer Jeol Scanning Electron Microscope EDAX Energy-Dispersive X-Ray Microanalysis Hach ® Turbidimeter Viscolite Viscometer Rigaku X-ray Fluorescence Analysis

Upload: others

Post on 08-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FILTER FEASIBILITY TESTING - Mott Corporation · 2020-06-05 · We will return any remaining unfiltered feed, collected solids and liquid filtrate samples to you for further analysis

M O T T C O R P. C O M | 8 6 0 - 7 4 7 - 6 3 3 3 | 8 4 S P R I N G L A N E | F A R M I N G T O N C T 0 6 0 3 2 | I S O 9 0 0 1 C E R T I F I E D 0 1 1 8 r e v

Filter testing designed to assess your unique conditions

To Optimize Your Filtration Process, Mott Will:

• Replicate or closely correlate your process conditions in our lab center

• Test various Mott filter media options under your conditions

• Provide you with a comprehensive performance report of Mott filtration technology in your process

• Make recommendations on media selection and filter design to optimize your manufacturing process

Get the Data You Need

• Particle Size Distribution (PSD)

• Feeds Solids Concentration

• Catalyst Recovery/Removal Rates

• Feed Viscosity

• Filtrate Clarity - PPM or Turbidity (NTU)

• Solids Cake Characteristics

• Flux Rates

• Pressure Drop Analysis

• Backwash Characterization

• Backpulse Characterization

FILTER FEASIBILITY TESTING

Rely on our Experience for Optimal Filtration Solutions

Take advantage of Mott Corporation’s fully equipped filtration testing laboratory to determine the optimal process operating parameters and filter design for your unique application. Testing is available for applications involving both liquid/solids and gas/solids.

Though applications may appear similar, slight differences, including operating temperature, solids content, particle size and distribution of solids, can significantly impact downstream product quality.

Using our lab’s highly advanced diagnostic equipment, our experienced engineers will provide you with a comprehensive, in-depth application analysis report and process operating parameter recommendations, including initial filter design recommendations.

We will return any remaining unfiltered feed, collected solids and liquid filtrate samples to you for further analysis and/or disposal.

Available Equipment

• Horiba Particle Size Distribution Analyzer

• Jeol Scanning Electron Microscope

• EDAX Energy-Dispersive X-Ray Microanalysis

• Hach® Turbidimeter

• Viscolite Viscometer

• Rigaku X-ray Fluorescence Analysis

Page 2: FILTER FEASIBILITY TESTING - Mott Corporation · 2020-06-05 · We will return any remaining unfiltered feed, collected solids and liquid filtrate samples to you for further analysis

M I S S I O N C R I T I C A L P R E C I S I O N

© 2018 Mott Corporation Hach® is registered trademark of Hach Company

M O T T C O R P. C O M | 8 6 0 - 7 4 7 - 6 3 3 3 | 8 4 S P R I N G L A N E | F A R M I N G T O N C T 0 6 0 3 2 | I S O 9 0 0 1 C E R T I F I E D F F T 0 1 1 8

Filtration of sub-micron particles (shown at 100x magnification)

How to Get Started

• Provide material safety data sheets for all chemicals

• Complete a Mott application data sheet

• Take responsibility for disposal of all samples

Ask a Mott representative for a sample report.

Precision analysis ensures optimal filtration results

State-of-the-art diagnostic equipment enables precision filtration recommendations

Rigaku X-ray fluorescence analysis