filtros sealkeen emflon ii
DESCRIPTION
Catalogo de filtros Sealkeen EmflonTRANSCRIPT
-
Air
/Gas
Ser
vice
Pro
duct
s
Description
Pall Sealkleen Junior style filter cartridgeswith double layer Emflon II hydrophobicpolyvinylidene fluoride (PVDF) membranesprovide reliable absolute removal of bac-teria and viruses from dry or wet air or gasstreams. The Pall Sealkleen assembly fea-tures a patented sanitary clamp sealingdesign which eliminates the possibility ofbypass from upstream to downstream.The assemblys in-line design and ease ofchange-out make it convenient for smallto moderate flow sterile tank vent and gassupply applications.
Double layer hydrophobic PVDF membranes High efficiency gas filter 0.2 m sterilizing grade Bacteria retentive in liquids 0.01m rated in gas flow Virus retentive in gases Broad chemical compatibility Low pressure loss 100% integrity tested Repeatedly steamable in situ Individually serialized Manufactured for use in conformance with cGMP
ISO 9000 Certified Quality System Pharmaceutical P optimized Certificate of Test provided
Specifications
Materials FDA-listed materials per 21 CFR Medium: Double layer, hydrophobic PVDF Support/Drainage Layers: Polypropylene Core/Cage/End Caps: Polypropylene
Removal Ratings Air/Gases:
-
For information or to order, call:
1-800-717-7255or 516-484-5400 Fax: 516-625-3610pharmafilter @ pall.comwww.pall.com
Air
/Gas
Ser
vice
Pro
duct
s
Air/Gas Service ProductsSmall Flow Cartridges
Part Numbers / Ordering Information
Part Nominal FilterNumber 10 Length AreaSLK7002V002PV 5.0 in. (127 mm) 2.3 ft2 (2150 cm2)SLK7001V002PV 2.5 in. (64 mm) 1.2 ft2 (1100 cm2)
Pressure Drop vs. Air Flow Rates9
9 Typical initial clean P, air at 68F (20C). For complete assembly pressure drop, add filter cartridge value to housing value at specified flow rate and inlet pressure. For gases other than air or nitrogen, contact your local Pall distributor.
Note: Curve labels denote length codes and inlet pressures.
10 P in the part number indicates optimized and qualified for pharmaceutical use including 100% integrity testing and Certificate of Test provided. V suffix indicates optimized for vent /air /gas service.
Note: For sizing assistance or scale-up to larger filters, contact your local Pall distributor.
Specifications and Availability: The informationprovided is a guide to the part number structureand possible options. Product availability may besubject to change without notice. All specificationsare nominal. This literature was reviewed for accu-racy at the time of publication. For current informa-tion on the products and test methodologies,consult your local Pall distributor.
7001 (50psig)
7001 (100psig)
0 20 8040 60Air Flow Rate (scfm) at Ambient Temperature
7002 (100psig) 7002 (50psig)
1
2
3
4
Clea
n Pr
essu
re D
rop
(psi
d)
0 Clea
n Pr
essu
re D
rop
(mba
r)
7001 (Vent) 7002 (Vent)
50
150
200
0
100
250
Air Flow Rate (Nm3/h) at Ambient Temperature 0 20 10060 8040 120