Contract FA8903-16-D-0027 Task Order 0004

Prepared for:

Air Force Civil Engineer Center

JBSA Lackland, Texas

March 2019

FINAL

SITE INSPECTION REPORT ADDENDUM 01

CANNON AIR FORCE BASE, NM

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Environmental

Programs Worldwide

This page intentionally left blank.

FINAL  

ADDENDUM 01 TO THE   FINAL SITE INSPECTION REPORT 

 SITE INSPECTION OF AQUEOUS FILM FORMING FOAM (AFFF) RELEASE AREAS 

ENVIRONMENTAL PROGRAMS WORLDWIDE  

CANNON AIR FORCE BASE CLOVIS, NEW MEXICO 

 Project No. RPMO20167118 

  Prepared for: 

Air Force Civil Engineer Center Joint Base San Antonio – Lackland, Texas 

 

 

 

 

 

 Prepared by: 

 

Amec Foster Wheeler Programs, Inc. 

Contract FA8903‐16‐D‐0027 Task Order 0004 

 

March 2019

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page iii  

TABLE OF CONTENTS 

ACRONYMS ......................................................................................................................................... vi 

EXECUTIVE SUMMARY ...................................................................................................................... viii 

1.0  INTRODUCTION ....................................................................................................................... 1   PROJECT OBJECTIVES .................................................................................................................... 2   PROJECT SCOPE ............................................................................................................................. 3 

2.0  BACKGROUND ......................................................................................................................... 5   INITIAL SITE INSPECTION ............................................................................................................... 5   HYDROGEOLOGIC SETTING ........................................................................................................... 5   POTENTIAL RECEPTORS ................................................................................................................. 7 

3.0  EXPANDED SI FIELD ACTIVITIES AND ANALYTICAL PROTOCOL .................................................. 9   AFFF RELEASE AREA 14: BASEWIDE GROUNDWATER ................................................................. 14 3.1.1  Sampling Summary ................................................................................................................................ 14 3.1.2  Analytical Results ................................................................................................................................... 14 3.1.3  Conclusions ............................................................................................................................................ 14   OFF‐BASE WATER SAMPLING ...................................................................................................... 15 3.2.1  Sampling Summary ................................................................................................................................ 15 3.2.2  Analytical Results ................................................................................................................................... 15 3.2.3  Conclusions ............................................................................................................................................ 15 

4.0  MIGRATION/EXPOSURE PATHWAYS AND TARGETS ............................................................... 17   GROUNDWATER EXPOSURE CONCLUSIONS ............................................................................... 17 

5.0  SUMMARY AND CONCLUSIONS ............................................................................................. 19 

6.0  REFERENCES .......................................................................................................................... 21 

   

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page iv  

FIGURES 

Figure 1.0‐1  Installation Location Map Figure 2.1‐1  2017 Groundwater Analytical Results (On‐Base) Figure 2.2‐1  2013 Groundwater Elevation Contours (Irrigation Season) Figure 2.2‐2  2015 Groundwater Elevation Contours (Non‐Irrigation Season) Figure 2.3‐1  Off‐Base Well Survey (New Mexico Office of State Engineer) Figure 3.0‐1  On‐Base Groundwater Sample Locations Figure 3.0‐2  Off‐Base Sample Locations Figure 3.1‐1  2018/2019 Groundwater Analytical Results (On‐Base) Figure 3.2‐1  2018 Off‐Base Water Sample Analytical Results (1.0‐mile) Figure 3.2‐2  2018 Off‐Base Water Sample Analytical Results (4.0‐mile)  

 

TABLES 

Table 1.0‐1         Regulatory Screening Values                                                                             (Page 2 in Report) Table 2.1‐1         Summary of 2017 Groundwater Analytical Testing Results                              (Tables Section) Table 2.3‐1         Off‐Base Well Locations – New Mexico Office of State Engineer                 (Tables Section) Table 3.0‐1         Monitoring Well Construction Details                                                                 (Tables Section) Table 3.0‐2         Groundwater Elevations                                                                                       (Tables Section) Table 3.0‐3         Off‐Base Sampling Location Summary            (Tables Section) Table 3.1‐1         Summary of Expanded Site Inspection Groundwater Analytical  

Testing Results (On‐Base)                     (Tables Section) Table 3.1‐2         Summary of Off‐Base Analytical Testing Results                                               (Tables Section)  Table 4.0‐1         Conceptual Site Model:  Installation‐Wide Summary                                        (Tables Section) Table 5.0‐1         Summary of Analytical Results and Screening Level Exceedances          (Page 19 in Report)  

 

 

 

 

 

 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page v  

APPENDICES 

Appendix A  Photograph Logs Appendix B  Field Forms 

B‐1  Field Activity Daily Logs B‐2  Daily PFAS Protocol Checklists  B‐3  Tailgate Safety Meeting Reports B‐4  Soil Boring/Monitoring Well Records B‐5  Well Development Forms B‐6  Water Quality Sampling Instrument Calibration Forms  B‐7   Groundwater Sampling Records  

Appendix C  Laboratory Analytical Reports (DVD) Appendix D  Data Validation Reports 

D‐1  December 2018 Data Validation Report (Groundwater Confirmation Sampling) D‐2  September 2018 Data Validation Report (August 2018 Private Well Sampling) D‐3  October 2018 Data Validation Report (September 2018 Private Well Sampling) D‐4  March 2019 Data Validation Report (MW‐Y) 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final  Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page vi  

ACRONYMS 

AFB    Air Force Base AFCEC    Air Force Civil Engineer Center AFFF    Aqueous Film Forming Foam Amec Foster Wheeler    Amec  Foster  Wheeler  Programs,  Inc.  and  its  affiliate  Amec  Foster 

Wheeler Environment & Infrastructure Inc. collectively  amsl    above mean sea level  bgs    below ground surface  BRAC    Base Realignment and Closure  Cascade    Cascade Environmental CoC    Chain‐of‐Custody  DL    detection limit DO    Dissolved Oxygen DoD    Department of Defense  ELAP    Environmental Laboratory Accreditation Program  FTA    Fire Training Area   HDPE    high‐density polyethylene  IDW    Investigation‐Derived Waste IRP    Installation Restoration Program ISWP    Installation‐Specific Work Plan ISWPA    Installation‐Specific Work Plan Addendum  LC‐MS/MS    Liquid Chromatography and Tandem Mass Spectrometry LHA    Lifetime Health Advisory LOQ    limit of quantification  µg/L    micrograms per liter  Maxxam    Maxxam Analytical   NMED    New Mexico Environment Department NMOSE    New Mexico Office of the State Engineer  PFAS    per‐ and polyfluorinated alkyl substances PFBS    perfluorobutanesulfonic acid PFOA    perfluorooctanoic acid 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final  Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page vii  

PFOS    perfluorooctanesulfonic acid PID  photoionization detector PPE    personal protective equipment PVC    polyvinyl chloride  ORP    Oxygen Reduction Potential  QPP    Quality Program Plan  RSL    Regional Screening Level  SI    Site Investigation SIR    Site Investigation Report SOP    Standard Operating Procedure  USAF    United States Air Force USDA        United States Department of Agriculture USEPA        United States Environmental Protection Agency USGS        United States Geological Survey  

   

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final  Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page viii  

EXECUTIVE SUMMARY 

This Addendum 01 to the Final Site  Inspection (SI) Report (SIR) was prepared by Amec Foster Wheeler Programs,  Inc.,  together with  affiliate Wood  Environmental &  Infrastructure  Solutions,  Inc.  (formerly known as Amec Foster Wheeler Environment &  Infrastructure,  Inc.)1, collectively  referred  to as Amec Foster Wheeler, under Contract No. FA8903‐16‐D‐0027, Task Order 0004,  to document  the  results of expanded SI activities conducted at Cannon Air Force Base (AFB) in Clovis, Curry County, New Mexico.   

Based on a review of the per‐ and polyfluorinated alkyl substances (PFAS) groundwater analytical data obtained  during  the  November/December  2017  SI  at  Cannon  AFB,  it  was  determined  that  further evaluation of perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA)  in groundwater at, and downgradient of, the  installation was required.   Concentrations of PFOS and PFOA were detected above the United States Environmental Protection Agency (USEPA) Lifetime Health Advisory (LHA) value of 0.07 micrograms per liter (µg/l); the maximum concentrations of PFOS and PFOA were 24 µg/l and 3.1 µg/l respectively.  Subsequent discussions between the Air Force Civil Engineer Center (AFCEC), Cannon AFB and Amec Foster Wheeler determined that further evaluation would consist of installing and sampling a groundwater monitoring well on Cannon AFB at the installation boundary; conducting resampling of six existing monitoring wells where PFOS and PFOA were detected at concentrations above screening levels; and, collection of water samples at off‐base properties southeast (downgradient) of Cannon AFB where groundwater is used as a source of drinking water for human consumption.   

The data presented in this SIR Addendum 01 were collected and evaluated in accordance with the Final Addendum 01  Installation‐Specific Work Plan  (ISWPA)  (Amec Foster Wheeler, 2018a) and  the General Quality Program Plan  (QPP)  (Amec Foster Wheeler, 2018b) and are meant to supplement the  findings presented in the Final SIR (Amec Foster Wheeler, 2018c).  An overview of PFAS and a discussion of the background for each of the aqueous film forming foam (AFFF) release areas were provided in the Final SIR (Amec Foster Wheeler, 2018c).  

The purpose of the expanded SI was to evaluate the potential for off‐base migration of PFOS and/or PFOA downgradient of AFFF Release Areas 1 (Former Fire Training Area [FTA] No. 2), 2 (Former FTA No. 3), 3 (Former FTA No. 4), 5  (Former Sewage Lagoons) and 11  (Active FTA).     Sixteen PFAS compounds were analyzed as part of the expanded SI activities in accordance with USEPA method 537.1 and in accordance with  the General QPP  (Amec Foster Wheeler, 2018b); however, only analytes with applicable  toxicity 

                                                            

1 Amec Foster Wheeler Environment & Infrastructure, Inc. changed its name on 6 April 2018 to Wood Environment &  Infrastructure  Solutions,  Inc.,  to  reflect  Wood  Group’s  acquisition  of  Amec  Foster  Wheeler.   All  resource documents created and activities conducted under Amec Foster Wheeler Environment & Infrastructure, Inc. remain in place, will be  referred  to Amec Foster Wheeler, and are executed under Wood Environment &  Infrastructure Solutions, Inc. 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final  Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page ix  

values (i.e., PFOS, PFOA and perfluorobutanesulfonic acid [PFBS]) were screened against human health risk‐based criteria and discussed in this addendum. 

Expanded SI PFAS Analytical Results 

The presence of PFOS, PFOA, and/or PFOS+PFOA at concentrations above the USEPA LHA value of 0.07 µg/L  was confirmed in on‐base groundwater monitoring wells MW‐Ca, MW‐D, MW‐Ga, MW‐Pa, MW‐Sa, and MW‐Ta.  The concentrations of PFOS, PFOA and/or PFOS+PFOA were generally consistent with the concentrations  detected  in  November/December  2017  and  reported  in  the  Final  SIR  (Amec  Foster Wheeler, 2018c).  

Analytical results for newly installed MW‐Y confirmed the presence of PFOS, PFOA and PFOS+PFOA at the installation boundary, downgradient of the former sewage lagoon area (AFFF release area 5) where PFOS and/or PFOS+PFOA were detected above the LHA in 2017.  The maximum concentrations of PFOS (0.13 µg/l),  PFOA  (0.0617  µg/l)  and  PFOS+PFOA  (0.192  µg/L) were  detected  in  the  duplicate  sample;  the concentrations of PFOS and PFOS+PFOA exceeded the LHA value.   

PFOS, PFOA, and/or PFOS+PFOA were detected at concentrations above the LHA in three off‐base water samples (CANON‐RES650‐01‐SP‐08292018, CANON‐RES650‐02‐SP‐08292018 and CANON‐RES948‐01‐SP‐08282018), confirming that groundwater impacted with PFOS or PFOA  at concentrations above the LHA values has migrated off‐base to the southeast.   

PFBS was not detected  in groundwater at concentrations above UESPA Tap Water Regional Screening Levels (RSLs) in on‐base or off‐base water samples. 

Groundwater Receptors 

Human receptors via the ingestion pathway were confirmed to be present downgradient of Cannon AFB.    Due  to  the detections of PFOS, PFOA and/or PFOS+PFOA at concentrations exceeding  the USEPA LHA values in off‐base properties where groundwater is used as a source of drinking water, the United States Air  Force  implemented  emergency  response measures  to  immediately provide  alternative  sources of drinking water  for  impacted  property  owners.    Bottled water was  immediately  offered  to  impacted property owners to mitigate the ingestion exposure.  Routine bottled water delivery service is ongoing at one of  the  affected properties  and will  continue until  longer  term water  treatment  technologies  are implemented.  The second property declined the bottled water service; however, they informed the Air Force  that  instead  of  bottled water,  they  prohibited  consumption  of water  for  all  personnel  at  the property,  a condition that will also continue until water treatment systems are installed. 

Due  to  PFOS,  PFOA  and/or  PFOS+PFOA  concentrations  exceeding  screening  levels  in  the  Basewide Groundwater, the Interim Response Action initiated during the expanded SI will be followed by the next phase  of  the  CERCLA  process,  Remedial  Investigation,  to  determine  the  extent  of  concentrations exceeding screening levels in groundwater that is a source of drinking water.

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final  Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 1  

1.0 INTRODUCTION 

This Addendum 01 to the Final Site  Inspection (SI) Report (SIR) was prepared by Amec Foster Wheeler Programs,  Inc.,  together with  affiliate Wood  Environmental &  Infrastructure  Solutions,  Inc.  (formerly known as Amec Foster Wheeler Environment &  Infrastructure,  Inc.)2, collectively  referred  to as Amec Foster Wheeler, under Contract No. FA8903‐16‐D‐0027, Task Order 0004,  to document  the  results of expanded SI activities conducted at, and downgradient of, Cannon Air Force Base (AFB) in Clovis, Curry County, New Mexico (Figure 1.0‐1).  Based on a review of the per‐ and polyfluorinated alkyl substances (PFAS) groundwater analytical data obtained during the November/December 2017 SI at Cannon AFB, it was determined that further evaluation of perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA) in groundwater at, and downgradient of the installation was required to evaluate the potential for off‐base migration.  Subsequent discussions between the Air Force Civil Engineer Center (AFCEC), Cannon AFB and Amec Foster Wheeler determined that further evaluation would consist of installing and sampling a groundwater monitoring well on Cannon AFB at the installation boundary; conducting resampling of six existing monitoring wells  at  the  installation where  PFOS, PFOA  and/or PFOS+PFOA were detected  at concentrations above screening levels; and, collection of samples from private water supply wells located southeast (downgradient) of the installation boundary.   

The data presented in this SIR Addendum 01 were collected and evaluated in accordance with the Final Addendum  01  Installation‐Specific Work  Plan  (ISWP)  (Amec  Foster Wheeler,  2018a)  and  the General Quality Program Plan  (QPP)  (Amec Foster Wheeler, 2018b) and are meant to supplement the  findings presented  in  the  Final  SIR  (Amec  Foster Wheeler, 2018c).   An overview of PFAS,  a discussion of  the background for each of the aqueous film forming foam (AFFF) release areas, and previous PFAS analytical results were provided in the Final SIR (Amec Foster Wheeler, 2018c).  

The  United  States  Environmental  Protection  Agency  (USEPA)  Office  of Water  issued  drinking water Lifetime Health Advisory (LHA) values for PFOS and PFOA in May 2016 that replaced the 2009 Provisional HA values.  The LHA values for PFOS and PFOA are 0.07 micrograms per liter (µg/L) for each constituent; however, when  these  two  chemicals  co‐occur  in  a drinking water  source,  a  conservative  and health‐protective approach is recommended that compares the sum of the concentrations (PFOS + PFOA) to the LHA  value (0.07 μg/L).  The LHA values are non‐regulatory concentrations of drinking water contaminants at or below which adverse health effects are not anticipated to occur over specific exposure durations (e.g.,  a lifetime).  They serve as informal technical guidance to assist federal, state, and local officials, and managers of public or community water systems  in protecting public health when emergency spills or 

                                                            

2 Amec Foster Wheeler Environment & Infrastructure, Inc. changed its name on 6 April 2018 to Wood Environment &  Infrastructure  Solutions,  Inc.,  to  reflect  Wood  Group’s  acquisition  of  Amec  Foster  Wheeler.   All  resource documents created and activities conducted under Amec Foster Wheeler Environment & Infrastructure, Inc. remain in place, will be  referred  to Amec Foster Wheeler, and are executed under Wood Environment &  Infrastructure Solutions, Inc. 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final  Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 2  

other  contamination  situations  occur.    A  LHA  document  provides  information  on  the  environmental properties, health  effects,  analytical methodology,  and  treatment  technologies  for  removing drinking water  contaminants.    Lifetime Health Advisory  values  are not  to be  construed  as  legally enforceable federal standards and are subject to change as new  information becomes available (USEPA, 2016a and 2016b). 

While PFOS and PFOA in groundwater are the focus of the LHA , the USEPA has also derived Tap Water Regional Screening Level (RSL) values for perfluorobutanesulfonic acid (PFBS) for which there is a Tier 2 toxicity value (Provisional Peer Review Toxicity Value) (USEPA, 2017a).   

Table 1.0‐1 below presents the screening values for comparing analytical results for PFOS, PFOA, and PFBS during the expanded SI.  The USEPA and New Mexico Environment Department (NMED) have not issued LHA values or promulgated standards for any other PFAS to date.   

Table 1.0‐1.  Regulatory Screening Values. 

Parameter Chemical Abstract Number 

USEPA Regional Screening Level Table  

(November 2017)a 

Calculated RSL for Soils and Sedimentsb  

USEPA Health Advisory for Drinking Water (Surface Water 

or Groundwater)c  Residential Soil 

(mg/kg) Tap Water 

(µg/L) (mg/kg)  (µg/L) 

PFOS  1763‐23‐1  NL  NL  0.126 0.07d 

 PFOA  335‐67‐1  NL  NL  0.126 

PFBS  375‐73‐5  130  40  NL  NL Notes: a  USEPA Regional Screening Levels (2017a) [https://semspub.epa.gov/work/HQ/197027.pdf]. b  Screening  levels  calculated  using  the  USEPA  Regional  Screening  Level  calculator  (https://epa‐prgs.ornl.gov/cgi‐bin/ chemicals/csl_search).  The calculated RSLs are based on a total hazard quotient of 0.1 as adopted by the USAF in March 2018 in revised guidance “PFAS Site Objectives and Follow‐On Activities”   

c  USEPA, May 2016a.  “Drinking Water Health Advisory for Perfluorooctane Sulfonate (PFOS)” and USEPA, May 2016b.  “Drinking Water Health Advisory for Perfluorooctanoic Acid (PFOA).”  

d When both PFOA and PFOS are both present, the combined concentrations of PFOA and PFOS should be compared with the 0.07 µg/L lifetime health advisory level.   

mg/kg ‐ milligrams per kilogram  PFOA ‐ perfluorooctanoic acid µg/L ‐ micrograms per liter  PFOS ‐ perfluorooctanesulfonic acid NL ‐ not listed  RSL ‐ Regional Screening Level PFBS ‐ perfluorobutanesulfonic acid  USEPA ‐ United States Environmental Protection Agency 

PROJECT OBJECTIVES 

In accordance with Department of Defense  (DoD)  Instruction 4715.18, “Emerging Contaminants  (ECs)” (DoD, 2009), the Interim AF Guidance on Sampling and Response Actions for Perfluorinated Compounds 

at Active and Base Realignment and Closure (BRAC) Installations (United States Air Force [USAF], 2012), and the SAF/IE Policy on Perfluorinated Compounds of Concern (USAF, 2016) the USAF will: 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final  Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 3  

1) Identify locations where there is a reasonable expectation that there may have been a release of PFOS or PFOA associated with USAF actions; 

2) Determine if there is unacceptable risk to human health and the environment; and, 

3) Address releases that pose an unacceptable risk, including offsite migration. 

The primary objectives of this expanded SI were to: 

Determine  whether  PFOS,  PFOA  and/or  PFOS+PFOA  are  present  in  groundwater  further downgradient of monitoring wells where the presence of these constituents was confirmed at concentrations above the LHA); and,  

Determine if PFOS and/or PFOA are present in groundwater at concentrations exceeding the LHA value in off‐base water wells where groundwater is currently used as a drinking water source for human consumption.   

 PROJECT SCOPE 

In order to evaluate the potential for off‐base migration of PFOS, PFOA, and PFBS, expanded SI activities included:  

The  installation  and  sampling  of  one  permanent  monitoring  well  (MW‐Y)  located  at  the installation boundary, southeast of monitoring wells MW‐Ga and MW‐Pa where PFOS, PFOA and PFOS+PFOA in groundwater were detected at concentrations exceeding the LHA.  The monitoring well will be screened in the Ogallala Formation with construction consistent with existing on‐base monitoring wells.   

Confirmation groundwater sampling was conducted at the six monitoring wells (MW‐Ca, MW‐D, MW‐Ga, MW‐Pa, MW‐Sa, and MW‐Ta) where PFOS, PFOA and/or PFOS+PFOA were previously detected at concentrations exceeding the LHA. 

Conducting  an  off‐base  well  inventory  survey  and  sampling  of  off‐base  water  wells  where groundwater was being used as a source of drinking water for human consumption.     

This SIR Addendum 01 discusses and provides a comparison of the expanded analytical results to screening values for PFOS, PFOA, and PFBS in groundwater (on‐base and off‐base).  The remaining PFAS do not have screening values; therefore, only the results of PFOS, PFOA, and PFBS are discussed in detail and presented in tables and figures.  However, all data are presented in the laboratory analytical reports provided in this SIR Addendum 01. 

   

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final  Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 4  

This page intentionally left blank.

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 5  

2.0 BACKGROUND 

Complete details on site location, setting, history and previous investigations performed at Cannon AFB are summarized in the SIR (Amec Foster Wheeler, 2018c).   

INITIAL SITE INSPECTION 

Data  collection activities  conducted during  the  initial SI  consisted of  collecting  soil,  sediment,  surface water and/or groundwater samples at the AFFF release areas summarized in the SIR.  The initial SI field activities were conducted in November and December 2017.   

Review of analytical results of the initial SI indicated that PFOS, PFOA and/or PFBS are present in soil and groundwater at Cannon AFB in excess of applicable USEPA RSLs and LHA values.  PFOS in surface soil was detected above the calculated RSL in AFFF release areas 2, 3, 4, 5, 9, and 11.  PFOS in subsurface soil was detected above the calculated RSL in AFFF Release Area 5.  PFOA and PFBS were detected in soil below the calculated RSLs, based on a residential scenario, at all AFFF release areas.  

Between 30 November and 14 December 2017, groundwater samples were collected  from 18 existing monitoring wells at Cannon AFB.  The validated groundwater analytical results revealed the presence of PFOS, PFOA and/or the sum of PFOS and PFOA (PFOS+PFOA) at concentrations exceeding the LHA value of  0.07  µg/l  in  six monitoring wells  (MW‐Ca, MW‐D, MW‐Ga, MW‐Pa, MW‐Sa,  and MW‐Ta).    Two monitoring wells, MW‐Ga and MW‐Pa are located in the east‐central portion of the installation, southeast of the former sewage lagoon area (AFFF Release Area 5); and the remaining four monitoring wells (MW‐Ca, MW‐D, MW‐Sa and MW‐Ta) are located in the southeast corner of the installation, southeast of both the active fire training area (FTA), and former FTAs including; FTA No. 2 (Installation Restoration Program [IRP] Site FT‐07), FTA No. 3 (IRP Site FT‐08) and FTA No. 4 (IRP Site FTA‐4). 

PFBS was detected in groundwater at concentrations below the Tap Water Regional Screening Level (RSL) in 11 of 18 monitoring wells sampled. 

Groundwater analytical results for PFOS, PFOA, PFOS+PFOA and PFBS (2017) are shown on Figure 2.1‐1, and provided in Table 2.1‐1.   

HYDROGEOLOGIC SETTING  

Cannon AFB is located in the Southern High Plains physiographic region of east‐central New Mexico, near the  center  of  the  Llano  Estacado  sub‐province  (United  States Geological  Survey  [USGS],  2006).    The predominant  geological  formations  in  the  vicinity  of  the  installation  consist  of  the Blackwater Draw, Ogallala, and Chinle Formations.   

The surface soils at Cannon AFB are predominantly fine sandy loams of the Amarillo series, which consist of deep, well drained, moderately permeable soils derived  from  the sandy deposits of  the Blackwater Draw Formation (United States Department of Agriculture [USDA], 2017).  The Quaternary age Blackwater 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 6 

Draw Formation is the uppermost geological unit at the installation and is composed primarily of eolian sand deposits ranging in thickness from 0 to 80 feet (USGS, 2006).   

The Blackwater Draw Formation generally overlies the Tertiary age Ogallala Formation.   The Ogallala  is comprised  of  eolian  sand  and  silt,  and  fluvial  and  lacustrine  derived  sand,  silt,  clay,  and  gravel,  and generally ranges in thickness from 30 to 600 feet in eastern New Mexico (AECOM, 2011).  The Ogallala Formation is the main water‐yielding unit of the Southern High Plains Aquifer and lies unconformably atop the upper unit of the Chinle Formation (USGS, 2016).  The Triassic Age Chinle Formation forms the bottom of the unconfined Southern High Plains Aquifer in the area of the installation and consists primarily of clay with some intermixed sand and silt, and ranges in thickness from 0 to 400 feet in eastern New Mexico (USGS, 2016). 

The lower portion of the Ogallala is part of the Southern High Plains Aquifer that extends across parts of southeast New Mexico and northwest Texas, which in turn is part of the larger High Plains Aquifer that extends continuously from Wyoming and South Dakota  into New Mexico and Texas.    In the vicinity of Cannon AFB, the Southern High Plains Aquifer is an unconfined aquifer that serves as the primary regional aquifer  for  both potable  and  irrigation water.    The underlying Chinle  Formation,  serves  as  the basal confining layer (aquitard) in eastern New Mexico (AECOM, 2011).  

At Cannon AFB,  the depth  to groundwater  ranges  from approximately 280  to 350  feet below ground surface (FPM, 2017).  Groundwater flow in the vicinity of Cannon AFB, is generally towards the southeast, with  localized  easterly  and  southerly  flow  components  and  is  heavily  influenced  by  the  pumping  of groundwater supplied, center‐pivot irrigation wells located downgradient (southeast) of the installation (USGS, 2016).  

Previous studies have been conducted to evaluate the hydrologic properties of the Southern High Plains Aquifer and to investigate potential seasonal fluctuations in groundwater flow direction associated with irrigation in the vicinity of Cannon AFB (USGS, 2016).  The groundwater flow contours depicted in Figure 2.2‐1 and Figure 2.2‐2 were interpreted by the USGS to document findings from groundwater monitoring during both the irrigation and non‐irrigation seasons.  Figure 2.2‐1 shows groundwater elevation contours interpreted by the USGS from data collected  in July 2013 to represent a typical  irrigation season; and, Figure  2.2‐2  shows  groundwater  elevation  contours  interpreted  by  the USGS  from  data  collected  in January 2015 for a typical non‐irrigation season (USGS, 2016).  As shown in both Figure 2.2‐1 and Figure 2.2‐2, the groundwater within the Ogallala Formation, at and near the installation, generally flows to the southeast during both  the  irrigation and non‐irrigation  seasons.   Additionally, Figures 2.2‐1 and 2.2‐2 identify  the  presence  of  a  northwest‐southeast  trending  groundwater  trough  that  is  evident  in  the southeast corner of the installation, extending several miles to the southeast.  According to the USGS, this groundwater trough is the hydraulic expression of a Tertiary age paleochannel, which is a feature common within the Southern High Plains Aquifer that contains coarser, more hydraulically conductive, materials than the surrounding subsurface materials (USGS, 2016). 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 7  

Data  collected  during  the November/December  2017  SI  indicated  that  the  depth  to  the  uppermost groundwater at the installation ranges from approximately 287 feet below ground surface (bgs) at MW‐X located  in  the  southwest  quadrant  to  350  feet  bgs  at  MW‐V  located  in  the  northwest  quadrant.  Groundwater  elevation  ranged  from  3981.45  feet  above mean  sea  level  (amsl)  in MW‐X  (southwest quadrant of installation) to 3933.68 feet amsl in MW‐Sa located in the southeast corner of the installation.  Groundwater  flow  within  this  uppermost  groundwater  unit  was  generally  towards  the  southeast, consistent with the data available from the USGS.   

POTENTIAL RECEPTORS  

Human receptors via the ingestion pathway are not present at Cannon AFB as the primary drinking water source for Cannon AFB is groundwater extracted from the Ogallala Aquifer using seven water supply wells located on‐base, up‐gradient of the identified AFFF release areas.  The installation water supply wells were previously  sampled  as part of  the Third Unregulated Contaminant Monitoring Rule  for PFAS with no detections reported. 

A review of water well records available  from  the New Mexico Office of  the State Engineer  (NMOSE), Water Rights Reporting System,  identified  the presence of 777 wells within 4‐miles of  the  installation boundary.  Of these 777 wells, 88 were identified as being potentially downgradient of the identified AFFF release areas and are shown on Figure 2.3‐1.  Details regarding well locations, depth, ownership and use are  provided  in  Table  2.3‐1.   Of  the  downgradient wells  identified within  4‐miles  of  the  installation boundary, 10 wells are identified as ‘domestic’ or ‘domestic and livestock’ water supply wells, including one domestic and livestock water supply well located within 1.0‐mile of the installation boundary; 13 wells were identified as ‘dairy’; two were identified as ‘monitoring’; and 63 were identified as ‘irrigation.’   

The residents of the properties downgradient of the installation that currently obtain drinking water from the ‘domestic’ or ‘domestic and livestock’ wells are considered potential receptors via the groundwater ingestion pathway.  Additionally, since no municipal water supply was identified in the area downgradient of  the  installation,  it  was  assumed  that  residents  of  properties  in  this  area  were  potentially  using unregistered wells (i.e., wells that are not included in the NMOSE Water Rights Reporting System) or other types of wells (i.e., irrigation wells) for domestic purposes.  In order to ensure that all potential drinking water wells were  identified, an off‐base reconnaissance consisting of a well  inventory survey (door‐to‐door) was conducted within approximately 4.0 miles downgradient of the installation. The results of the well inventory survey are summarized in Section 3.0. 

 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 8  

This page intentionally left blank.

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 9  

3.0 EXPANDED SI FIELD ACTIVITIES AND ANALYTICAL PROTOCOL  

Expanded SI activities were conducted at Cannon AFB between 28 August 2018 and February 14, 2019.   Photographic  documentation  of  the  expanded  SI  activities  is  provided  in  Appendix  A  and  field documentation is provided in Appendix B.  Inspection activities were recorded by field personnel on field activity daily  logs (Appendix B‐1).   Daily PFAS protocol checklists were completed to ensure PFAS were not  introduced by Amec Foster Wheeler employees or subcontractors  in accordance with SOP AFW‐01 (PFAS)–Field Sampling Protocols to Avoid Cross‐Contamination of PFAS (Appendix B‐2).  A tailgate safety meeting was conducted each morning prior to beginning work, with the tailgate safety meeting reports provided in Appendix B‐3. 

Permanent Monitoring Well Installation and Well Development 

One permanent groundwater monitoring well  (MW‐Y) was  installed at  the  installation boundary,  in a location  downgradient  of  the  former  sewage  lagoon  area  (AFFF  release  area  5) where  PFOS  and/or PFOS+PFOA were detected in groundwater above the LHA  in 2017.  The monitoring well was installed to evaluate  the potential  for PFOS and/or PFOS+PFOA  to have migrated off‐base  relative  to  the  former sewage lagoon area. 

The monitoring well was  installed by Cascade Environmental  (Cascade), a New Mexico  licensed driller using rotosonic methodology.  Soil cores were continuously collected to the total depth of the well boring, screened with  a portable photoionization detector  (PID)  for  volatile organic  vapors,  and  logged by  a qualified geoscientist in accordance with the Unified Soil Classification System.  Drilling information, PID readings,  and  geologic  logging  observations  are  included  in  the  Soil  Boring/Monitoring Well  records provided in Appendix B‐4.   

The monitoring well was  constructed using  four‐inch diameter,  schedule 80,  flush  threaded polyvinyl chloride (PVC) riser casing and type 304, stainless steel, continuous slot, wire wrap flush threaded well screen possessing a 0.010‐inch slot width (#10 slot) and end cap.  The monitoring well screen length was 40 feet and the top of the screen was set approximately 3 feet above the field observed depth of the water table.  The riser casing and screen were set in a minimum 8‐inch diameter borehole.  The annular space surrounding the well screen was backfilled with clean 20/40 silica sand during rotosonic drill casing withdrawal to approximately 3 feet above the top of the well screen.  An approximate 8‐foot bentonite transition seal was then installed above the sand pack and allowed to hydrate overnight before sealing the remaining borehole annulus with a cement/bentonite grout to grade.   

The monitoring  well  was  completed  with  an  above‐grade  surface  completion  consisting  of  a  steel protective casing with a 3‐foot by 3‐foot by 6‐inch concrete pad set in the ground.  The monitoring well was  installed  in accordance with SOP AFW‐04, Monitoring Well  Installation (Appendix D, General QPP) and  in accordance with New Mexico Administrative Code Title 19, 027, 0004 and applicable  rules and regulations  for well  construction  outlined  by  the New Mexico Office  of  the  State  Engineer/Interstate 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 10  

Stream Commission.  Monitoring well construction details are presented in Table 3.0‐1 and are illustrated in the Soil Boring/Monitoring Well Records provided in Appendix B‐4.   

The new monitoring well was developed after the grout had been allowed to set for a minimum of 72 hours.   Development was completed by surging and pumping with a stainless‐steel submersible pump fitted with disposable high‐density polyethylene (HDPE) tubing in accordance with SOP AFW‐05 (PFAS), Monitoring Well  Development  (Appendix  D,  General  QPP).   Water  quality  parameters  (pH,  specific conductance, temperature, oxidation‐reduction potential [ORP], dissolved oxygen [DO], and turbidity) of the development water were measured and recorded on a well development log, and a minimum of three saturated casing volumes of water was purged  from  the well during development.   The development information was recorded on a Well Development form provided in Appendix B‐5. 

On‐Base Groundwater Sampling 

Groundwater  sampling  conducted  as  part  of  the  expanded  SI  activities  was  completed  during  two separate mobilizations.    The  first mobilization was  conducted between 22  and 27 October 2018  and consisted of collecting groundwater confirmation samples from the six monitoring wells (MW‐Ca, MW‐D, MW‐Ga, MW‐Pa, MW‐Sa, and MW‐Ta) where PFOS, PFOA and/or PFOS+PFOA were previously detected at  concentrations  exceeding  the  LHA.    The  second mobilization was  conducted  between  11  and  14 February 2019 and consisted of development and sampling of the newly installed monitoring well (MW‐Y).   

Prior to collecting groundwater samples, depth to water measurements were collected from each well sampled.  Groundwater elevation data is summarized in Table 3.0‐2. 

Groundwater  samples  from  the  first mobilization were  collected with  a  stainless  steel Grundfos  SQE submersible pump fitted with stainless steel drop piping.  The stainless steel drop piping was connected to a galvanized steel and a brass manifold which was connected to a flow‐through cell whereby recovered groundwater was monitored  for pH,  temperature,  specific  conductivity, DO,  and ORP.   Turbidity was measured using a separate turbidity meter.   

Groundwater samples from the second mobilization were collected with the same model of pump used during the first mobilization, which was attached to HDPE tubing using a stainless steel hose clamp.  The tubing was connected directly to a flow‐through cell at the well head whereby recovered groundwater was monitored for pH, temperature, specific conductivity, DO, and ORP.  Turbidity was measured with a separate turbidity meter. 

Groundwater sampling equipment was calibrated prior to use, with the resulting data recorded on water quality sampling instrument calibration forms contained in Appendix B‐6.  Purge water was pumped into a storage trailer tank through a 1‐inch hose.  Depth to water measurements, and field parameters, were monitored until groundwater indicator parameters reached stabilization criteria in accordance with SOP AFW‐03  (PFAS)‐Groundwater  Sampling  (Appendix  D, General QPP).    The  flow‐through  cell was  then 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 11  

removed and groundwater  samples were  collected directly  into  laboratory‐provided HDPE  containers from the brass discharge port.  The sample containers were sealed, labeled, packed on ice in an insulated cooler, and delivered to Maxxam under chain‐of‐custody (CoC) protocol.  Groundwater sampling activities were documented on Groundwater Sampling Logs provided in Appendix B‐7.  

Off‐Base Private Well Survey and Groundwater Sampling 

The  off‐base  private  well  inventory  survey  and  sampling  was  conducted  during  two  separate mobilizations, the first mobilization was conducted between 27 and 30 August 2018 and the second was conducted  between  25  and  27  September  2018.    The  private  well  survey  area  encompassed approximately 4.0‐miles downgradient (southeast) of the AFFF release areas where PFOS, PFOA and/or PFOS+PFOA were  detected  at  concentrations  above  the  LHA  in  2017.   During  the  door‐to‐door well inventory survey, a total of 21 property owners indicated they utilized wells for domestic (i.e., drinking water) purposes.    Several property owners  indicated  that one or more wells were being  utilized  for domestic purposes, resulting in a total of 25 sampling locations being identified, in comparison to the 10 domestic wells identified in the NMOSE Water Rights Reporting System.   

Prior to the Amec Foster Wheeler reconnaissance, Cannon AFB personnel coordinated with local property owners  to  communicate  the  background  and  purpose  of  the  well  inventory  survey  and  to  obtain permission from property owners to conduct water sampling on their property.   A total of 19 primary water samples from 16 properties were collected during the first mobilization.  Properties that could not be accessed during the first mobilization were revisited during the second mobilization and an additional six primary water samples were collected from six properties. 

Private water supply sampling was conducted in accordance with SOP‐AFW‐13 (PFAS), Private and Public Water Supply Well Sampling  (Appendix D, General QPP).   The water samples were collected by  filling sample containers directly from sample ports at each identified location.  Amec Foster Wheeler personnel relied on information provided by property owners to select the most appropriate sampling location at each of the properties, with preference being to collect samples from tap or spigot locations, at, or near, the well  head  or  pump  house  and  before  the water  supply  is  introduced  into  any  storage  tanks  or treatment units.    In some  instances, samples were required to be collected from manifolds at storage tanks due to conditions encountered in the field such as the well heads being inaccessible (i.e., buried or represented a confined space condition) or were not fitted with sampling ports.  A summary of sample locations is provided in Table 3.0‐3.   

Prior to collecting each sample, the sampling port was allowed to flush for at least 15 minutes.  The flow rate was measured and recorded to calculate the purge volume.  During purging, a minimum of three sets of water  quality  parameters  (pH,  specific  conductance,  temperature,  ORP,  and  DO) were  collected.  Groundwater sampling equipment was calibrated prior to use, with the resulting data recorded on water quality sampling instrument calibration forms contained in Appendix B‐6.   Following purging, the samples 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 12  

were collected directly from the sample port  into  laboratory‐supplied containers.   Private well sample collection logs were completed for each sample and copies are included in Appendix B‐7. 

Surveying 

The newly installed monitoring well was surveyed by a New Mexico Licensed Professional Surveyor (Amec Foster Wheeler, Albuquerque, New Mexico) for horizontal coordinates, ground surface elevations and top of riser elevation.  Horizontal coordinates were surveyed based on New Mexico State Plane Coordinate System, East Zone, United States Survey Feet, North American Datum of 1983.  The elevation data were collected based on North American Vertical Datum of 1988.  Survey data for the existing monitoring wells was provided by Cannon AFB personnel (Table 3.0‐1). 

The horizontal coordinates for the off‐base sampling locations were recorded in the field using a hand‐held global positioning system. 

Total Sample Counts 

The following provides a summary of samples collected during expanded SI activities at Cannon AFB: 

13 water  samples  (including  six  primary  groundwater  samples,  one  duplicate  sample  and  six equipment  blank  samples)  were  collected  in  October  2018  as  part  of  the  groundwater confirmation sampling effort; 

Three groundwater  samples  (including one duplicate  sample and one equipment blank) were collected in February 2019 following installation of MW‐Y; 

53 water samples (including 25 primary groundwater samples, three duplicate samples and 25 field blanks [one per primary sample]), were collected in August and September 2018 at off‐base sampling  locations.      The  field  blanks were  initially  held  at  the  laboratory  and  subsequently analyzed for those primary samples where PFOS and/or PFOA were detected at concentrations exceeding the LHA. 

Samples collected during the expanded SI were analyzed for the same 16 PFAS compounds as identified in the SIR. 

Groundwater samples collected from base monitoring wells were analyzed by Maxxam and the off‐base water samples were analyzed by Vista Analytical, both are DoD Environmental Laboratory Accreditation Program  (ELAP) certified  laboratories.   Samples were analyzed by Modified USEPA Method 537 using Liquid Chromatography and Tandem Mass Spectrometry (LC‐MS/MS).  The LC‐MS/MS method provides acceptable detection limits to confirm the presence of the PFAS listed above.   

Analytical  results  for  PFOS,  PFOA,  and  PFBS  are  discussed  in  the  following  sections.    The  laboratory analytical reports for all PFAS constituents are included in Appendix C.  

Co‐occurrence of PFOS and PFOA (PFOS + PFOA)  in aqueous samples was reported using the following guidelines: 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 13  

1. If PFOS and PFOA are both detected at concentrations at or above the laboratory detection limit (DL)  in  groundwater,  then  the  reported  concentration  for  PFOA was  added  to  the  reported concentration for PFOS. 

2. If only PFOS or only PFOA is detected at or above the DL in groundwater, then the concentration of the detected analyte only is reported.  

3. If neither PFOA nor PFOS are detected at concentrations at or above the DL, then co‐occurrence was reported as Not Detected. 

Data Validation and Usability Assessment  

Analytical  laboratory data  from groundwater confirmation samples collected and analyzed  for PFAS  in October 2018 were validated by Amec Foster Wheeler in December 2018.  A total of 13 water samples were collected during the groundwater confirmation sampling event, including one field duplicate, and six field blanks.  During validation, Amec Foster Wheeler evaluated a total of 112 data records from field samples.  No data were qualified during the validation and 100 percent of the data were considered fully usable without qualification.  A copy of the data validation report is included as Appendix D‐1. 

Analytical laboratory data from drinking water samples collected and analyzed for PFAS in August 2018 were validated by Amec Foster Wheeler  in September 2018.   During validation, Amec Foster Wheeler evaluated  a  total of 352 data  records  from  field  samples  and  J qualified  six  records  (1.7 percent)  as estimated values because of analyte concentrations between the DL and limit of quantification (LOQ).  No PFOS, PFOA or PFBS data were qualified.   All data were considered  fully usable with  the qualification identified.  A copy of the September 2018 data validation report is included as Appendix D‐2. 

Analytical  laboratory data  from drinking water samples collected and analyzed  for PFAS  in September 2018 were validated by Amec Foster Wheeler in October 2018.  During validation, Amec Foster Wheeler evaluated a total of 112 data records from field samples and J qualified one record (0.9 percent) as an estimated value because of a detection of PFOA in sample CANON‐RES1591‐01‐SP‐09262018 between the DL and LOQ.  All data were considered fully usable with the qualification identified.  A copy of the October 2018 data validation report is included as Appendix D‐3. 

Analytical laboratory data from PFAS sampling of newly installed monitoring well (MW‐Y) were validated by Amec  Foster Wheeler  in March  2019.   A  total  of  three water  samples were  collected during  this sampling event, including one field duplicate, and one equipment blank.  During validation, Amec Foster Wheeler evaluated a  total of 32 data  records  from  field  samples.   No data were qualified during  the validation and 100 percent of the data were considered fully usable without qualification.  A copy of the data validation report is included as Appendix D‐4. 

Investigation‐Derived Waste 

Investigation‐Derived  Waste  (IDW)  generated  during  the  expanded  SI  activities  conducted  on  the Installation  consisted  of  soil  cuttings  from  monitoring  well  installation,  well  development  water, 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 14  

groundwater sampling purge water, equipment decontamination water, disposable personal protective equipment (PPE), and other miscellaneous refuse.   

Used PPE and other miscellaneous refuse were placed in plastic bags and discarded into an on‐site sanitary trash container for disposal at a sanitary landfill.  Soil IDW was containerized in a 25 cubic yard roll‐off box and  liquid  IDW was staged  in a 4,000‐gallon poly‐tank.   Composite groundwater and soil  IDW samples were collected from the staged  IDW generated during the expanded SI.   The samples were  laboratory analyzed  by  Maxxam  for  PFAS  and  by  CT  Laboratories  in  Baraboo,  Wisconsin  for  volatile  organic compounds,  semi‐volatile  organic  compounds,  pesticides,  herbicides,  and  metals,  polychlorinated biphenyls, total petroleum hydrocarbons (gasoline range organics and diesel range organics), flashpoint, pH, sulfide, and cyanide, to determine the applicable disposal options (Appendix C).   

The  IDW  is  currently  being managed  on‐site  pending  receipt  of  analytical  results.   Waste  disposal manifests will be provided under separate cover, following off‐base transport and disposal. 

AFFF RELEASE AREA 14: BASEWIDE GROUNDWATER 

3.1.1 Sampling Summary 

Six existing on‐base groundwater monitoring wells; MW‐Ca, MW‐D, MW‐Ga, MW‐Pa, MW‐Sa, and MW‐Ta were resampled between 22 and 27 October 2018 to confirm the presence and concentrations of PFOS, PFOA and/or PFOS+PFOA that were detected at concentrations exceeding the LHA during the  initial SI.  The sample locations are shown on Figure 3.0‐1.   

A groundwater sample was also collected from the newly installed monitoring well (MW‐Y) on February 13, 2019.  This monitoring well was installed at the installation boundary to determine the presence of PFOS and PFOA in groundwater, downgradient of the former sewage lagoon area (AFFF release area 5), where PFOS  and/or PFOS+PFOA were detected  in  groundwater  at  concentrations  exceeding  the  LHA during the initial SI.  The location of MW‐Y is shown on Figure 3.0‐1.   

3.1.2 Analytical Results 

Nine groundwater samples (including two field duplicates) were collected for PFOS and PFOA analysis.  Groundwater analytical results are provided in Table 3.1‐1 and illustrated on Figure 3.1‐1.   

3.1.3 Conclusions 

The results of the groundwater sampling confirmed the presence of PFOS, PFOA, and/or PFOS+PFOA at concentrations exceeding the LHA  in the six wells which were resampled.  The concentrations of PFOS, PFOA  and/or  PFOS+PFOA  were  comparable  to  those  reported  in  each monitoring  well  sampled  in December 2017 and as reported in the Final SIR (Amec Foster Wheeler, 2018c).   

The results of groundwater sampling from newly installed MW‐Y confirmed the presence of PFOS, PFOA, PFOS+PFOA and PFBS, downgradient of the former sewage lagoon area (AFFF release area 5), where PFOS 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 15  

and/or PFOS+PFOA were previously detected in groundwater above the LHA.  The concentrations of PFOS and PFOS+PFOA in groundwater at MW‐Y exceeded the LHA. 

PFBS was not detected above the Tap Water RSL in groundwater. 

OFF‐BASE WATER SAMPLING 

3.2.1 Sampling Summary 

A total of 25 groundwater samples were collected at off‐base  locations where groundwater was being used as the primary drinking water.  The sampling locations are shown on Figure 3.0‐2.   

3.2.2 Analytical Results 

A total of 28 groundwater samples (including three field duplicates) were collected for PFOS and PFOA analysis.  The analytical results are provided in Table 3.1‐2 and illustrated on Figures 3.2‐1 and 3.2‐2.   

3.2.3 Conclusions 

The concentrations of PFOS, PFOA, and/or PFOS+PFOA in groundwater exceeded the LHA in three of the off‐base  samples  (CANON‐RES650‐01‐SP‐08292018,  CANON‐RES650‐02‐SP‐08292018  and  CANON‐RES948‐01‐SP‐08282018).  PFBS was not detected above the Tap Water RSL in off‐base sample locations.  Off‐base  groundwater  sampling  results  confirm  that  groundwater  impacted with  PFOS,  PFOA  and/or PFOS+PFOA at concentrations above the LHA values has migrated off‐base to the southeast.   

 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 16  

This page intentionally left blank.

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 17  

4.0 MIGRATION/EXPOSURE PATHWAYS AND TARGETS 

An updated base‐wide conceptual site model  table  is provided as Table 4.0‐1.   The  table provides an overview of the facility, physical description, AFFF release area, land use, exposure, and ecological profiles for Cannon AFB.  The table has been updated to include information collected during the expanded SI.  A detailed description of soil, sediment and surface water relative to source area conditions are provided in the SIR (Amec Foster Wheeler, 2018c).    

GROUNDWATER MIGRATION PATHWAY 

PFOS  and  PFOA, once  in  groundwater,  are highly mobile  and will migrate  near  the  same  velocity  as groundwater due to their high solubility and low partition coefficient value (i.e., soil/water as compared to other traditional chemicals such as benzene).  Groundwater flow velocity in the vicinity of Cannon AFB is estimated to be on the order of 0.9 feet per day (ft/day).  This estimate is based on an average hydraulic conductivity for the Ogallala aquifer of 60 feet/day (USGS, 1995), a hydraulic gradient of 0.003 feet per foot (AECOM, 2011), and an effective porosity of 0.2 (estimated based on Cannon AFB geology).   PFOS and PFOA  are  chemically  and biologically  stable  in  the  environment  and  resist  typical  environmental degradation  processes.    PFBS  is  generally  less  toxic  and  less bioaccumulative  in wildlife  and humans (USEPA, 2017b). 

During the expanded SI activities, PFOS, PFOA, and/or PFBS were detected in groundwater at six existing basewide monitoring wells.   PFOS, PFOA, and/or PFOS+PFOA exceeded  the LHA value of 0.07 µg/L  in monitoring wells MW‐Ga and MW‐Pa located east of the former sewage lagoons and in monitoring wells MW‐Ca, MW‐D, MW‐Sa and MW‐Ta, all located in the southeast corner of the installation.  These findings were consistent with those reported in the Final SIR (Amec Foster Wheeler, 2018c).  PFBS was detected at  concentrations  below  the USEPA  Tap Water  RSL  in  all  groundwater  samples  collected  during  the expanded SI activities.   

Based on  the current PFOS and PFOA analytical results, groundwater at Cannon AFB  is  impacted with PFOS, PFOA and/or PFOS+PFOA at concentrations above the LHA at locations downgradient of the former sewage lagoon area (AFFF release area 5) and the fire training areas (former and active) located in the southeast corner of the installation (AFFF release areas 1, 2, 3 and 11).  Although groundwater is regulated basewide by NMED, AFFF release areas 1, 2, 3, 5 and 11 are considered groundwater release areas for pathway analysis. 

The primary groundwater exposure targets include off‐base property owners located within the Tertiary‐age paleochannel, immediately southeast of the Cannon AFB installation boundary, and downgradient of AFFF release areas 1, 2, 3, 5, and 11.   Potential exposure routes  in drinking water  include  ingestion of impacted groundwater. 

GROUNDWATER EXPOSURE CONCLUSIONS 

Human receptors via the ingestion pathway are present downgradient of Cannon AFB.   

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 18  

Due to the detections of PFOS, PFOA and/or PFOS+PFOA at concentrations exceeding the LHA values in off‐base properties where groundwater  is used as a source of drinking water,  the USAF  implemented emergency response measures and immediately offered bottled water to impacted property owners to mitigate the ingestion exposure.   

Routine bottled water delivery service is ongoing at one of the affected properties and will continue until longer term water treatment technologies are implemented.  The second property declined the bottled water  service;  however,  they  informed  the  Air  Force  that  instead  of  bottled water,  they  prohibited consumption of water for all personnel at the property,   a condition that will also continue until water treatment systems are installed. 

 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 19  

5.0 SUMMARY AND CONCLUSIONS 

As stated in Section 1.0, the objectives of this expanded study were to: 

Determine whether  PFOS  and/or  PFOA  are  present  in  groundwater  further  downgradient  of monitoring  wells  where  the  presence  of  PFOS,  PFOA  and/or  PFOS+PFOA  was  confirmed  at concentrations above the LHA); and,  

Determine if PFOS and/or PFOA are present in groundwater at concentrations exceeding the LHA value in off‐base water wells where groundwater is currently used as a drinking water source for human consumption.   

A total of 18 existing monitoring wells, representing the basewide groundwater, were sampled for PFOS and PFOA.  Most of the monitoring wells sampled are located downgradient of known and/or suspected AFFF release areas,  including Landfill #4, the Former Sewage Lagoons, North Playa Lake Outfall, South Playa Lake Outfall, the current FTA, and Former FTAs 2‐4.  Based on the analytical results from these 18 monitoring wells, a release of AFFF was confirmed in the Basewide Groundwater impacting groundwater that is a known source of drinking water, which could create a potential hazard to human health.  Due to PFOS and/or PFOA concentrations exceeding screening levels in the Basewide Groundwater, the Interim Response Action  initiated during  the  expanded  SI will be  followed by  the  next phase of  the CERCLA process, Remedial Investigation, to determine the extent of PFOS and/or PFOA concentrations exceeding screening levels in groundwater that is a source of drinking water. 

Section 3 of  this SIR Addendum 01 detailed  the analytical  results  for PFOS and PFOA  included  in  this expanded SI.  A summary table (Table 5.0‐1) is also provided below which lists specific exceedances by area and media, fulfilling the objectives of the expanded SI. 

   

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 20  

Table 5.0‐1. Summary of Analytical Results and Screening Level Exceedances. 

Location ID  Parameter 

Maximum Detected 

Concentration 

Screening Value  Units 

Number of Samples*/ Number of 

Exceedances

Exceeds Screening 

Level 

Potentially Complete 

DW Exposure Pathway 

Recommen‐dation 

AFFF Release Area 14  

Groundwater  ‐ Existing Wells     PFOS  25  0.07  µg/L  6/4  Yes 

Yes  Advance to RI 

PFOA  2.8  0.07  µg/L  6/4  Yes PFOS+PFOA  27  0.07  µg/L  6/6  Yes 

PFBS 0.97 

40  µg/L 6/0  No 

Off‐Base Survey Area 

Off‐Base     PFOS  1.1  0.07  µg/L  25/3  Yes 

Yes Interim Response Action 

PFOA  0.539  0.07  µg/L  25/2  Yes PFOS+PFOA  1.649  0.07  µg/L  25/3  Yes 

PFBS  0.210  40  µg/L  25/0  No  Notes: * includes normal and field duplicate samples (count does not include QC samples) AFFF – aqueous film forming foam  DW – Drinking Water J – The analyte was positively identified and the associated numerical value is the approximate concentration of the analyte in the sample µg/L – micrograms per liter  ND – not detected PFBS – perfluorobutanesulfonic acid PFOS – perfluorooctanesulfonic acid PFOA – perfluorooctanoic acid  

Groundwater Receptors 

Human  receptors  via  the  ingestion  pathway  are  present  downgradient  of  Cannon  AFB.   Due  to  the detections of PFOS, PFOA and/or PFOS+PFOA at  concentrations exceeding  the  LHA values  in off‐base properties where groundwater is used as a source of drinking water, the USAF implemented emergency response measures to mitigate immediate exposure.  Bottled water was immediately offered to impacted property owners to mitigate the ingestion exposure.  Routine bottled water delivery service is ongoing at one of  the  affected properties  and will  continue until  longer  term water  treatment  technologies  are implemented.  The second property declined the bottled water service; however, they informed the Air Force  that  instead  of  bottled water,  they  prohibited  consumption  of water  for  all  personnel  at  the property,  a condition that will also continue until water treatment systems are installed.

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 21  

6.0 REFERENCES 

AECOM, 2011. Facility‐Wide Long Term Groundwater Monitoring Plan. March. 

Amec  Foster Wheeler  Environment  &  Infrastructure,  Inc.  (Amec  Foster Wheeler),  2017a.    Final  Site Inspection  of  Aqueous  Film  Forming  Foam  (AFFF)  Release  Areas,  Environmental  Programs 

Worldwide, Installation‐Specific Work Plan, Cannon Air Force Base, Clovis, New Mexico, June. 

Amec Foster Wheeler, 2017b.  Final Site Inspection of Film Forming Foam (AFFF) Release Areas Quality 

Program Plan, March. 

Amec Foster Wheeler, 2018a.  Final Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas, 

Environmental Programs Worldwide,  Installation‐Specific Work Plan Addendum 01, Cannon Air 

Force Base, Clovis, New Mexico, June. 

Amec Foster Wheeler, 2018b.  Final Site Inspection of Film Forming Foam (AFFF) Release Areas Quality 

Program Plan Revision 2, August. 

Amec Foster Wheeler, 2018c.  Final Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas, 

Environmental Programs Worldwide, Site Inspection Report, Cannon Air Force Base, Clovis, New 

Mexico, August. 

DoD, 2009.  Department of Defense, Instruction Number 4715.18 Emerging Contaminants (ECs), 11 June. 

FPM, 2017.  2016 Biennial Groundwater Monitoring and Annual Landfill Inspection Report.  Cannon Air Force Base, New Mexico.  RCRA Permit No. NM7572124454.  February. 

NMED, 2011.   Monitoring Well Construction and Abandonment Guidelines, New Mexico Environment Department, Ground Water Quality Bureau. United States Air Force (USAF), 2012.  Interim USAF 

Guidance on Sampling and Response Actions for Perfluorinated Compounds at Active and Base 

Realignment and Closure Installations, August. 

USAF, 2016.  SAF/IE Policy on Perfluorinated Compounds (PFCs) of Concern, August. 

USAF, 2018.  Guidance of PFAS Site Inspection Objectives and Follow‐On Activities, April. 

United  States  Department  of  Agriculture  (USDA),  2017.    Soil  Survey,  Natural  Resources  Conservation Service, Web Soil Survey https://websoilsurvey.nrcs.usda.gov 

United States Geological Survey (USGS), 1995.  Ground Water Atlas of the United States, Arizona, Colorado, 

New Mexico, Utah; High Plains Aquifer.  https://pubs.usgs.gov/ha/ha730/ 

 USGS, 2016.   Potentiometric Surfaces, Summer 2013 and Winter 2015, and Select Hydrographs for the Southern High Plains Aquifer, Cannon Air Force Base, Curry County, New Mexico, 2016. 

USEPA, 2014.  USEPA Fact Sheet.  Emerging Contaminants Fact Sheet – PFOS and PFOA, March. 

USEPA, 2016a.  Drinking Water Health Advisory for Perfluorooctane Sulfonate (PFOS), 19 May. 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Final Addendum 01 to the Final Site Inspection Report 

Cannon Air Force Base, Clovis, New Mexico March 2019 

Page 22  

USEPA, 2016b.  Drinking Water Health Advisory for Perfluorooctanoic Acid (PFOA), 19 May. 

USEPA,  2017a.  Regional  Screening  Levels  (RSLs)  – Generic  Tables  (November  2017).  Retrieved  from https://www.epa.gov/risk/regional‐screening‐levels‐rsls‐generic‐tables‐november‐2017. 

USEPA,  2017b.   Assessing  and Managing  Chemicals  under  TSCA,  Per‐  and  Polyfluoroalkyl  Substances 

(PFASs)  under  TSCA.    Updated  13  March.    https://www.epa.gov/assessing‐and‐managing‐chemicals‐under‐tsca/and‐polyfluoroalkyl‐substances‐pfass‐under‐tsca,  accessed  on  12  April, 2017. 

FIGURES

This page intentionally left blank.

FIGURE ACRONYMS

AFFF aqueous film forming foam ft bgs feet below ground surface µg/L micrograms per liter PFAS per- and polyfluorinated alkyl substances PFBS perfluorobutanesulfonic acid PFOA perfluorooctanoic acid PFOS perfluorooctanesulfonic acid

FIGURE NOTES

Purple shaded = Exceeds applied USEPA Health Advisory Value or RSL Groundwater elevations in NAVD88 (feet) A Higher concentration observed in field duplicate sample J = The analyte was positively identified and the associated numerical value is the approximate concentration of the analyte in the sample Off-base well locations are provided from the New Mexico Office of State Engineer’s Water Rights Database. Well use codes shown on figures include: DAI DAIRY OPERATION DOL 72-12-1 DOMESTIC AND LIVESTOCK WATERING DOM 72-12-1 DOMESTIC ONE HOUSEHOLD IRR IRRIGATION MON MONITORING WELL PUB 72-12-1 CONSTRUCTION OF PUBLIC WORKS

Symbol KeyCannon AFB Installation Boundary

Site Inspection of AqueousFilm Forming Foam (AFFF)

Release AreasEnvironmental Programs WorldwideSite Inspection Report Addendum 01

FIGURE 1.0-1Installation Location MapCannon Air Force Base

Clovis, New Mexico

_̂NM

TX

CO

OK

KS

Se rvice Laye r Cre dits:Copyr ight:© 201 3 Nat io nal

Geog rap hic Socie ty, i-cu bed

Pa

th:

H:\

Pro

jects

\77

53

03

10

1_

US

AF

_A

ctive

_P

FC

s\0

00

6_

Ca

nn

on

\MX

Ds\S

IR_

Ad

d1

\Fig

ure

1-0

-1 -

Site

Lo

ca

tio

n.m

xd

Project: 775303101.CNFO01

Date: 3/1/2019By: M.Vavraµ0 3,0001,500 Feet

Air Force Civil Engineer Center2261 Hughes Ave., Suite 163JBSA Lackland, Texas 78236

Service Layer Credits: Copyright:© 2013National Geographic Society, i-cubed

FOR OFFICIAL USE ONLY (FOUO). This document contains information

which must be protectedIAW the Privacy Act of 1974 (5 U.S.C. 552a), DoD 5400.11R, AFI 33-332, and AFI 31-401.

@A?

@A?

@A?

@A?

@A?@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

Well H

Well E

Well D

Well Ua

Well X

Well V

Well Ra

Well Pa

Well Oa

Well Sa

Well F

Well W

Well Na

Well G

Well Ta

Well C

Well B

Well A

Site Inspection of AqueousFilm Forming Foam (AFFF)

Release AreasEnvironmental Programs WorldwideSite Inspection Report Addendum 01

FIGURE 2.1-12017 Groundwater Analytical

Results (On-Base)Cannon Air Force Base

Clovis, New Mexico

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

11/30/2017 361 0.015 U 0.01 U ND 0.015 U

MW‐V

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

12/1/2017 361 0.015 U 0.01 U ND 0.015 U

MW‐W

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

12/2/2017 341 0.015 U 0.01 U ND 0.015 U

MW‐E

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

12/5/2017 341 0.041 0.0019 J 0.06 J 0.0074 B

MW‐H

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

11/30/2017 321 0.015 UJ 0.01 UJ ND 0.015 UJ

MW‐X

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

12/6/2017 321 0.015 U 0.01 U ND 0.0062 B

MW‐A

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

12/13/2017 341 0.015 U 0.023 0.023 0.079 B

MW‐B

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

12/13/2017 341 0.79 3.1A 3.85A 0.29

MW‐D

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

12/13/2017 346 0.015 U 0.01 J 0.01 J 0.048 B

MW‐Ua

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

12/13/2017 356 0.015 U 0.24 0.24 0.37

MW‐Ta

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

12/14/2017 356 0.15 B 1.5 1.65 0.71

MW‐Sa

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

12/14/2017 346 24 2.2 26.2 0.84

MW‐Ca

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

12/4/2017 346 0.087 JA 0.045 J 0.13 0.049 Q

LF25‐MW‐Pa

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

12/5/2017 346 0.0086 J 0.042 0.0506 J 0.096 B

LF03‐MW‐Oa

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

12/6/2017 341 0.13 0.071 0.201 0.11 B

MW‐Ga

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

12/12/2017 341 0.015 U 0.01 U ND 0.015 U

MW‐Fa

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

12/3/2017 326 0.015 U 0.01 U ND 0.015 U

LF25‐MW‐RbSample Date

Sample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

12/3/2017 341 0.015 U 0.01 U ND 0.015 U

LF04‐MW‐Na

Docum

ent P

ath: H:\P

rojects\77

5303

101_

USAF_

Active_

PFC

s\00

06_C

annon\MXDs\SIR_A

dd1\Figure 2-1-1 - G

W Results.mxd

μProject: 775303101.CNFO01

By: M.Vavra Date: 3/1/2019

0 1,000 2,000Feet

Air Force Civil Engineer Center

2261 Hughes Ave., Suite 163JBSA Lackland, Texas 78236

Symbol Key

@A? Monitoring Well

@A?Monitoring Well with PFASExceedance

AFFF Release Area

AFFF Release Area(Approximate)

Cannon AFB InstallationBoundary

ft bgsug/L PFASPFOSPFOAPFBS

U

JB

ND

A

feet below ground surfacemicrograms per literPer- and Polyfluoroalkyl SubstancesPerfluorooctanesulfonic acidPerfluorooctanoic acidPerfluorobutanesulfonic acidThe analyte was analyzed for but was notdetected above the reported limit of detection.The result is estimatedThe analyte was found in an associated blankPFOA+PFOS could not be calculated due tonon-detectsA higher concenteration was observed in thefield duplicate sample and is shown

Service Layer Credits: Source: Esri, DigitalGlobe,GeoEye, Earthstar Geographics, CNES/Airbus DS,USDA, USGS, AeroGRID, IGN, and the GIS User

Community

FOR OFFICIAL USE ONLY (FOUO). This document contains information

which must be protectedIAW the Privacy Act of 1974 (5 U.S.C. 552a), DoD 5400.11R, AFI 33-332, and AFI 31-401.

@A?

@A?

@A?

@A?@A?@A?

@A?@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

MW-E

MW-A

MW-Ua

MW-X

MW-Pa

MW-Na

MW-Oa

MW-Sa

MW-Fa

MW-W

MW-Rb

MW-Ga

MW-TaMW-Ca

MW-B

MW-D

MW-H

MW-Y

3970

3970

3970

3990

400

0

3860

399

0

3870

3980

3980

3880

3890

3900

3910

3920

3930

3940

3950

3960

3970

Site Inspection of AqueousFilm Forming Foam (AFFF)

Release AreasEnvironmental Programs WorldwideSite Inspection Report Addendum 01

FIGURE 2.2-12013 Groundwater ElevationContours (Irrigation Season)

Cannon Air Force BaseClovis, New Mexico

Docum

ent P

ath: H:\P

rojects\77

5303

101_

USAF_

Active_

PFC

s\00

06_C

annon\MXDs\SIR_A

dd1\Figure 2-2-1 - S

ummer Con

tours.mxd

μProject: 775303101.CNFO01

By: M.Vavra Date: 3/5/2019

0 3,000 6,000Feet

Service Layer Credits: Source: Esri, DigitalGlobe, GeoEye,Earthstar Geographics, CNES/Airbus DS, USDA, USGS,

AeroGRID, IGN, and the GIS User Community

Air Force Civil Engineer Center

2261 Hughes Ave., Suite 163JBSA Lackland, Texas 78236

Symbol Key

@A? Monitoring Well

Approximate Groundwater ElevationContour - Summer (USGS July 2013)

Approximate Groundwater FlowDirection (USGS 2013)

AFFF Release AreaAFFF Release Area (Approximate)Cannon AFB Installation Boundary1-Mile Installation Boundary4-Mile Installation Boundary

FOR OFFICIAL USE ONLY (FOUO). This document contains information

which must be protectedIAW the Privacy Act of 1974 (5 U.S.C. 552a), DoD 5400.11R, AFI 33-332, and AFI 31-401.

@A?

@A?

@A?

@A?@A?@A?

@A?@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

MW-E

MW-A

MW-Ua

MW-X

MW-Pa

MW-Na

MW-Oa

MW-Sa

MW-Fa

MW-W

MW-Rb

MW-Ga

MW-TaMW-Ca

MW-B

MW-D

MW-H

MW-Y

3850

400

0

3990

3860

399

0

3980

3870

388

0

3980

3970

389

0

397

0

390039

10

3920

3930

3940

39503960

Site Inspection of AqueousFilm Forming Foam (AFFF)

Release AreasEnvironmental Programs WorldwideSite Inspection Report Addendum 01

FIGURE 2.2-22015 Groundwater Elevation

Contours (Non-Irrigation Season)Cannon Air Force Base

Clovis, New Mexico

Docum

ent P

ath: H:\P

rojects\77

5303

101_

USAF_

Active_

PFC

s\00

06_C

annon\MXDs\SIR_A

dd1\Figure 2-2-2 - S

ummer Con

tours.mxd

μProject: 775303101.CNFO01

By: M.Vavra Date: 3/5/2019

0 3,000 6,000Feet

Service Layer Credits: Source: Esri, DigitalGlobe, GeoEye,Earthstar Geographics, CNES/Airbus DS, USDA, USGS,

AeroGRID, IGN, and the GIS User Community

Air Force Civil Engineer Center

2261 Hughes Ave., Suite 163JBSA Lackland, Texas 78236

Symbol Key

@A? Monitoring Well

Approximate Groundwater ElevationContour - Winter (USGS January 2015)

Approximate Groundwater Flow Direction(USGS 2015)

AFFF Release AreaAFFF Release Area (Approximate)Cannon AFB Installation Boundary1-Mile Installation Boundary4-Mile Installation Boundary

FOR OFFICIAL USE ONLY (FOUO). This document contains information

which must be protectedIAW the Privacy Act of 1974 (5 U.S.C. 552a), DoD 5400.11R, AFI 33-332, and AFI 31-401.

@A?

@A?

@A?

@A?@A?@A?

@A?@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A? @A?@A?

@A?@A?

@A?

!( !(

!(

!(!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(!(!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!( !(

!(

!(

!(

!(

!(

!(!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(!(

!(!(

!(

!(

!(

!( !(

!(

!(

!(

!(

!(!( !(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(!(

!(

!(

!(

!(

!(

!(

!(

!(!(!(!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(!(!(!(!(!( !(!(!(!(!(!(!(!( !(!( !(!(!(!(!(!(!(!( !(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(!(

!(

!(!(

!(

!(

!(

!(

!(

!(!(

!(

!( !(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(!(

!(

!(

!(

!(

!(!(!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(!(

!(!(

!(

!( !(!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(!(

!(!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(!(!(

!(

!( !(

!(

!(

!(

!(

!(

!(

!(

!(

!A

!A

@A?

MW-E

MW-A

MW-Ua

MW-X

MW-Pa

MW-Na

MW-Oa

MW-Sa

MW-Fa

MW-W

MW-Rb

MW-Ga

MW-TaMW-Ca

MW-B

MW-D

MW-H

54

3

85

81

37

56

34

22

55

44

63

66

14

19

4

8

9

7

12

5

64

82

79

62

76

80

68

69

1626

18

21

30 3110

13

60

57

27

38

75

70

46

51

43

45

50

59

23

24

48

41

42

53

35

52

39

40

67

15

25

73

29

11

32

2

78

83

86

8777

72

65 74

88

84

1

6

36

71

49

33

28

61

20

17

47

58

Site Inspection of AqueousFilm Forming Foam (AFFF)

Release AreasEnvironmental Programs WorldwideSite Inspection Report Addendum 01

FIGURE 2.3-1Off-Base Well Survey(New Mexico Office of

State Engineer)Cannon Air Force Base

Clovis, New Mexico

Docum

ent P

ath: H:\P

rojects\77

5303

101_

USAF_

Active_

PFC

s\00

06_C

annon\MXDs\SIR_A

dd1\Figure 2-3-1 - W

ell S

urvey.mxd

μProject: 775303101.CNFO01

By: M.Vavra Date: 3/5/2019

0 3,000 6,000Feet

Service Layer Credits: Source: Esri, DigitalGlobe, GeoEye,Earthstar Geographics, CNES/Airbus DS, USDA, USGS,

AeroGRID, IGN, and the GIS User Community

Air Force Civil Engineer Center

2261 Hughes Ave., Suite 163JBSA Lackland, Texas 78236

Symbol Key

@A? Monitoring Well with PFAS Exceedance

@A? Monitoring Well

Approximate Groundwater Elevation Contour- Winter (USGS January 2015)

Approximate Groundwater Flow Direction(USGS 2015)

AFFF Release Area

AFFF Release Area (Approximate)

Cannon AFB Installation Boundary

1-Mile Installation Boundary

4-Mile Installation Boundary

Potentially Contaminated Groundwater inDowngradient Direction

NM Water Rights Database

!( DOM

!( DAI

!( DOL

!( IRR

!A MON

PUB

!( Wells Upgradient of Identified Contamination

FOR OFFICIAL USE ONLY (FOUO). This document contains information

which must be protectedIAW the Privacy Act of 1974 (5 U.S.C. 552a), DoD 5400.11R, AFI 33-332, and AFI 31-401.

MW-Y

@A?

@A?

@A?

!@A?

@A?@A?

!@A?!@A?

@A?

!@A?

@A?

@A?

!@A?

@A?

@A?

!@A?

@A?

@A?

!@A?

Eureka Ave

C R

R

Arcadia Ave

Casablanca Ave

Terminal Ave

E Argentia Ave

Sextant AveTrident Ave

En

gin

eers

Wa

y

Octagon Ave

Hirosh

ima

St

E P

eri

me

ter

Rd

Libe

rato

r Ave

Casablanca Ave

No Perimeter Rd

Co Rd 8

Cu

rry

Rd

P

W P

eri

met

er

Rd

D L

Ingr

am B

lvd

S Perimeter Rd

Olym

pic

Runw

ay 2

2/04

Taxi

way R

Taxiway C

Taxiway D

Runway 13/31

Taxiway F

Taxiway A

Taxiway B

MW-H

MW-E

MW-A

MW-D

MW-B

MW-Ua

MW-Ta

MW-X

MW-Ga

MW-V

MW-Rb

MW-Pa

MW-Na

MW-Oa

MW-Sa

MW-Fa

MW-W

MW-Ca

MW-Y

Symbol Key

!@A? Monitoring Well Location Sampledfor Follow On Activites

@A? Monitoring Well Location

RoadsAFFF ReleaseAFFF Release Area(Approximate)

Cannon AFB InstallationBoundaryLandfill 5

Site Inspection of AqueousFilm Forming Foam (AFFF)

Release AreasEnvironmental Programs WorldwideSite Inspection Report Addendum 01

FIGURE 3.0-1On-Base Groundwater

Sample LocationsCannon Air Force Base

Clovis, New Mexico

Se rvice Laye r Cr edits:So urce : Esri,Dig italGlo be, GeoEye ,Ea rths tarGeog rap hics,CNES/Airb us DS,USDA, USGS,

Path: H:\P

rojects\77

530310

1_USAF_

Active_

PFC

s\00

06_C

anno

n\MXDs\SIR_A

dd1\Figure 3-0-1 - Add01

Sam

ple Locations.m

xd

Project: 775303101.CNFO01

Date: 3/5/2019By: M.Vavraμ0 1,000 2,000500 Feet

Air Force Civil Engineer Center

2261 Hughes Ave., Suite 163JBSA Lackland, Texas 78236

Service Layer Credits: Source: Esri, DigitalGlobe,GeoEye, Earthstar Geographics, CNES/Airbus DS,USDA, USGS, AeroGRID, IGN, and the GIS User

Community

FOR OFFICIAL USE ONLY (FOUO). This document contains information

which must be protectedIAW the Privacy Act of 1974 (5 U.S.C. 552a), DoD 5400.11R, AFI 33-332, and AFI 31-401.

@A?

@A?

@A?

@A?

@A?@A?

@A?@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

!H

!H

!H

!H

!H

!H

!H

!H

!H

!H

!H

!H!H

!H

!H!H

!H

!H

!H

!H

!H

!H

!H

!H

!H

@A?

MW-H

MW-E

MW-A

MW-Ua

MW-Pa

MW-Na

MW-Oa

MW-Sa

MW-Fa

MW-Ga

MW-Rb

MW-B

MW-TaMW-Ca

MW-D

MW-W

CANON-RES748-01-SP

CANON-RES730-01-SP

CANON-RES948-01-SP

CANON-RES778-01-SP

CANON-RES738-01-SP

CANON-RES1358-01-SP

CANON-RES650-01-SP

CANON-RES650-02-SP

CANON-RES725-01-SP

CANON-RES717-01-SP

CANON-RES682-01-SP

CANON-RES648-01-SP

CANON-RES1369-02-WH

CANON-RES1369-01-SP

CANON-RES1461-01-SP

CANON-RES1591-01-SP

CANON-RES1495-01-SP

CANON-RES1349-01-SP

CANON-RES1310-01-SP

CANON-RES546-01-SP

CANON-RES1331-01-WH

CANON-RES650-03-SP

CANON-RES692-01-SP

CANON-RES1397-01-SP

CANON-RES1369-03-WH

3980

38

60

3970

3980

3960

3870

3880

389

0

3960

3970

3900

391039

20

39303940

3950

W Brady Ave

Ora Dr

Pioneer Dr

Appaloosa Dr

Bri

an

ne

Dr

Ora

Dr

Oxb

ow

Ln

Homestead Rd

Settler Pl

Sky

line

Dr

Con

est

oga

Trl

Heritage Rd

Ad

am

s S

t

Rose Dr

Curry Road 4

Sumac Trl

Grove St

Curry Rd 5

Curry Road 8

Jesse Ave

S Perimeter Rd

Cur

ry R

oa

d P

Pio

nee

r R

d

Cottonwood Dr

Cr

P

S W

hea

ton

St

Curry Road 7

Cur

r y R

d N

Cur

ry R

d W

Sta

te H

wy

46

7

Curry Road 9

Curry Road 7

Curry Road 6

Cur

ry R

d M

Site Inspection of AqueousFilm Forming Foam (AFFF)

Release AreasEnvironmental Programs WorldwideSite Inspection Report Addendum 01

FIGURE 3.0-2Off-Base Sample Locations

Cannon Air Force BaseClovis, New Mexico

Docum

ent P

ath: H:\P

rojects\77

5303

101_

USAF_

Active_

PFC

s\00

06_C

annon\MXDs\SIR_A

dd1\Figure 3-0-2 - O

ff-Base Sam

ple Locations.mxd

μProject: 775303101.CNFO01

By: M.Vavra Date: 3/5/2019

0 2,000 4,000Feet

Service Layer Credits: Source: Esri, DigitalGlobe, GeoEye,Earthstar Geographics, CNES/Airbus DS, USDA, USGS,

AeroGRID, IGN, and the GIS User Community

Air Force Civil Engineer Center

2261 Hughes Ave., Suite 163JBSA Lackland, Texas 78236

FOR OFFICIAL USE ONLY (FOUO). This document contains information

which must be protectedIAW the Privacy Act of 1974 (5 U.S.C. 552a), DoD 5400.11R, AFI 33-332, and AFI 31-401.

Symbol Key

!H Off-Base Sample Location

@A? Monitoring Well with PFAS Exceedance

@A? Monitoring Well

Approximate Groundwater ElevationContour - Summer (USGS, 2016)Approximate Groundwater Flow Direction(USGS 2015)Approximate Parcel Boundaries

AFFF Release Area

AFFF Release Area (Approximate)

Cannon AFB Installation Boundary

1-Mile Installation Boundary

4-Mile Installation Boundary

MW-Y

@A?

@A?

@A?

@A?

@A?@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

MW-Y

MW-H

MW-E

Well D

MW-Ua

MW-X

MW-V

MW-Rb

Well Pa MW-Oa

Well Sa

MW-Fa

MW-W

MW-Na

Well G

Well Ta

Well C

MW-B

MW-A

Site Inspection of AqueousFilm Forming Foam (AFFF)

Release AreasEnvironmental Programs WorldwideSite Inspection Report Addendum 01

FIGURE 3.1-12018/2019 Groundwater

Analytical Results (On-Base)Cannon Air Force Base

Clovis, New Mexico

Docum

ent P

ath: H:\P

rojects\77

5303

101_

USAF_

Active_

PFC

s\00

06_C

annon\MXDs\SIR_A

dd1\Figure 3-1-1 - C

onfirm Sam

ple Results.m

xd

μProject: 775303101.CNFO01

By: M.Vavra Date: 3/5/2019

0 1,000 2,000Feet

Service Layer Credits: Source: Esri, DigitalGlobe, GeoEye,Earthstar Geographics, CNES/Airbus DS, USDA, USGS,

AeroGRID, IGN, and the GIS User Community

Air Force Civil Engineer Center

2261 Hughes Ave., Suite 163JBSA Lackland, Texas 78236

ft bgsug/L PFASPFOSPFOAPFBS

U

A

feet below ground surfacemicrograms per literPer- and Polyfluoroalkyl SubstancesPerfluorooctanesulfonic acidPerfluorooctanoic acidPerfluorobutanesulfonic acidThe analyte was analyzed for but was notdetected above the reported limit of detection.A higher concenteration was observed in thefield duplicate sample and is shown

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

10/23/2018 346 0.051 0.024 0.075 0.023

LF25‐MW‐PA

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

10/22/2018 341 0.13 0.056 0.186 0.1

MW‐GA

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

10/27/2018 346 25A 2 27A 0.66A

MW‐CA

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

10/27/2018 341 0.96 2.8 3.76 0.18

MW‐D

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

10/24/2018 356 0.081 1.6 1.681 0.97

MW‐SA

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

10/23/2018 356 0.015 U 0.34 0.34 0.54

MW‐TA

FOR OFFICIAL USE ONLY (FOUO). This document contains information

which must be protectedIAW the Privacy Act of 1974 (5 U.S.C. 552a), DoD 5400.11R, AFI 33-332, and AFI 31-401.

Symbol Key

@A? Monitoring Well

@A?Monitoring Well withPFAS Exceedance

AFFF Release Area

AFFF Release Area(Approximate)

Cannon AFBInstallation Boundary

Sample DateSample Depth 

(ft bgs)

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

2/13/2019 330 0.13A 0.0617A 0.192A 0.0606A

MW‐Y

@A?

@A?

@A?

@A?

@A?@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

@A?

!H

!H

!H

!H

!H

!H

!H

!H

!H!H

!H

!H

@A?MW-Y

Ora

Dr

Jesse Ave

Curry Road 8

S Perimeter Rd

Curry Road 9

Cur

ry R

d P

Cur

ry R

d W

Curry Road 7 State Hwy 467

Pe

ri me

ter R

d

ato

CANON-RES948-01-SP

CANON-RES778-01-SP

CANON-RES738-01-SP

CANON-RES650-01-SP

CANON-RES650-02-SP

CANON-RES725-01-SP

CANON-RES717-01-SP

CANON-RES682-01-SP

CANON-RES1495-01-SP

CANON-RES1591-01-SP

CANON-RES650-03-SP

CANON-RES692-01-SP

MW-H

Well E

MW-A

MW-D

MW-B

MW-Ua

MW-Ca

MW-Ta

MW-Ga

MW-Rb

MW-Pa

MW-Na

MW-Oa

MW-Sa

MW-Fa

MW-W

3960

3980

3980

3900

3970

3970

3910

3920

3930

3960

3940

3950

Site Inspection of AqueousFilm Forming Foam (AFFF)

Release AreasEnvironmental Programs WorldwideSite Inspection Report Addendum 01

FIGURE 3.2-12018 Off-Base Water

Sample AnalyticalResults (1.0-Mile)

Cannon Air Force BaseClovis, New Mexico

Docum

ent P

ath: H:\P

rojects\77

5303

101_

USAF_

Active_

PFC

s\00

06_C

annon\MXDs\SIR_A

dd1\Figure 3-2-1 - O

ff-Base Sam

ple Results NW.mxd

μProject: 775303101.CNFO01

By: M.Vavra Date: 3/5/2019

0 1,000 2,000Feet

Service Layer Credits: Copyright:É 2013 NationalGeographic Society, i-cubed

Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics,CNES/Airbus DS, USDA, USGS, AeroGRID, IGN, and the

Air Force Civil Engineer Center

2261 Hughes Ave., Suite 163JBSA Lackland, Texas 78236

FOR OFFICIAL USE ONLY (FOUO). This document contains information which must be protectedIAW the Privacy Act of 1974 (5 U.S.C. 552a), DoD 5400.11R,

AFI 33-332, and AFI 31-401.

Symbol Key

!H Off-Base Sample Location

@A? Monitoring Well with PFAS Exceedance

@A? Monitoring Well

Approximate Groundwater Elevation Contour -Summer (USGS, 2016)

Approximate Groundwater Flow Direction(USGS 2015)

Approximate Parcel Boundaries

AFFF Release Area

AFFF Release Area (Approximate)

Cannon AFB Installation Boundary

1-Mile Installation Boundary

4-Mile Installation Boundary

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/28/2018 0.0953 0.0506 0.146 0.0641

CANON‐RES948‐01‐SP‐08282018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

9/26/2018 0.00417 U 0.00793 J 0.00793 J 0.00862

CANON‐RES1591‐01‐SP‐09262018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/28/2018 0.00439 U 0.00439 U ND  0.00439 U

CANON‐RES778‐01‐SP‐08282018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/29/2018 0.0042 U 0.0042 U ND  0.0164

CANON‐RES717‐01‐SP‐08292018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/28/2018 0.00463 U 0.00463 U ND  0.0111

CANON‐RES738‐01‐SP‐08282018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/29/2018 0.0041 U 0.0041 U ND  0.0145

CANON‐RES725‐01‐SP‐08292018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/29/2018 0.00427 U 0.00427 U ND  0.00427 U

CANON‐RES692‐01‐SP‐08292018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

9/25/2018 0.0042 U 0.0042 U ND  0.0042 U

CANON‐RES1495‐01‐SP‐09252018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/29/2018 0.404 0.267 0.671 0.137

CANON‐RES650‐02‐SP‐08292018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/29/2018 1.11 0.539 1.65 0.210

CANON‐RES650‐01‐SP‐08292018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/29/2018 0.00442 U 0.00442 U ND  0.00442 U

CANON‐RES650‐03‐SP‐08292018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/29/2018 0.0042 U 0.0042 U ND  0.0042 U

CANON‐RES682‐01‐SP‐08292018

ug/L PFASPFOSPFOAPFBS

U

JND

micrograms per literPer- and Polyfluoroalkyl SubstancesPerfluorooctanesulfonic acidPerfluorooctanoic acidPerfluorobutanesulfonic acidThe analyte was analyzed for but was notdetected above the reported limit of detection.The result is estimatedPFOA+PFOS could not be calculated due tonon-detects

!H

!H

!H

!H

!H!H

!H

!H

!H

!H

!H

!H

!H

Ora Dr

Rose Dr

Grove St

Jesse Ave

Curry Road 7

Sta

te H

wy

46

7

Curry Road 7

Cur

ry R

d N

Curry Road 5

Curry Road 6

Cur

ry R

d M

Curry Road 8 39503950

3920

3860

3910

3900

3870

3940

3930

3920

3910

3900

38

80

3890

3930

CANON-RES748-01-SP

CANON-RES730-01-SP

CANON-RES1358-01-SP

CANON-RES1369-02-WH

CANON-RES1369-01-SP

CANON-RES1461-01-SP

CANON-RES1349-01-SP

CANON-RES1310-01-SP

CANON-RES546-01-SP

CANON-RES1331-01-WH

CANON-RES648-01-SP

CANON-RES1369-03-WH

CANON-RES1397-01-SP

Site Inspection of AqueousFilm Forming Foam (AFFF)

Release AreasEnvironmental Programs WorldwideSite Inspection Report Addendum 01

FIGURE 3.2-22018 Off-Base Water

Sample AnalyticalResults (4.0-Mile)

Cannon Air Force BaseClovis, New Mexico

Docum

ent P

ath: H:\P

rojects\77

5303

101_

USAF_

Active_

PFC

s\00

06_C

annon\MXDs\SIR_A

dd1\Figure 3-2-2 - O

ff-Base Sam

ple Results SE.m

xd

μProject: 775303101.CNFO01

By: M.Vavra Date: 3/5/2019

0 1,000 2,000Feet

Service Layer Credits: Copyright:É 2013 NationalGeographic Society, i-cubed

Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics,CNES/Airbus DS, USDA, USGS, AeroGRID, IGN, and the

Air Force Civil Engineer Center

2261 Hughes Ave., Suite 163JBSA Lackland, Texas 78236

FOR OFFICIAL USE ONLY (FOUO). This document contains information which must be protectedIAW the Privacy Act of 1974 (5 U.S.C. 552a), DoD 5400.11R,

AFI 33-332, and AFI 31-401.

Symbol Key

!H Off-Base Sample Location

@A? Monitoring Well with PFAS Exceedance

@A? Monitoring Well

Approximate Groundwater Elevation Contour -Summer (USGS, 2016)

Approximate Groundwater Flow Direction(USGS 2015)

Approximate Parcel Boundaries

AFFF Release Area

AFFF Release Area (Approximate)

Cannon AFB Installation Boundary

1-Mile Installation Boundary

4-Mile Installation Boundary

ug/L PFASPFOSPFOAPFBS

U

JND

micrograms per literPer- and Polyfluoroalkyl SubstancesPerfluorooctanesulfonic acidPerfluorooctanoic acidPerfluorobutanesulfonic acidThe analyte was analyzed for but was notdetected above the reported limit of detection.The result is estimatedPFOA+PFOS could not be calculated due tonon-detects

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/28/2018 0.00435 U 0.00435 U ND  0.00435 U

CANON‐RES748‐01‐SP‐08282018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/28/2018 0.00413 U 0.00413 U ND  0.00413 U

CANON‐RES730‐01‐SP‐08282018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/28/2018 0.00435 U 0.00435 U ND  0.00435 U

CANON‐RES1358‐01‐SP‐08282018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/30/2018 0.00413 U 0.00413 U ND  0.00413 U

CANON‐RES1397‐01‐SP‐08302018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/30/2018 0.00424 U 0.00424 U ND  0.00424 U

CANON‐RES1369‐01‐SP‐08302018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/30/2018 0.00431 U 0.00431 U ND  0.00431 U

CANON‐RES1369‐02‐WH‐08302018Sample Date

PFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/30/2018 0.0041 U 0.0041 U ND  0.0041 U

CANON‐RES1369‐03‐WH‐08302018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/30/2018 0.0100 0.0155 0.0255 0.0103

CANON‐RES648‐01‐SP‐08302018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

8/30/2018 0.00417 U 0.00417 U ND  0.00417 U

CANON‐RES1461‐01‐SP‐08302018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

9/26/2018 0.00413 U 0.00413 U ND  0.00413 U

CANON‐RES1331‐01‐WH‐09262018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

9/26/2018 0.00413 U 0.00413 U ND  0.00413 U

CANON‐RES1349‐01‐SP‐09262018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

9/27/2018 0.00413 U 0.00413 U ND  0.00413 U

CANON‐RES1310‐01‐SP‐09272018

Sample DatePFOS(μg/L)  

PFOA(μg/L) 

PFOA+PFOS (μg/L) 

PFBS(μg/L)

9/26/2018 0.00427 U 0.00427 U ND  0.00427 U

CANON‐RES546‐01‐SP‐09262018

TABLES

This page intentionally left blank.

Table 2.1‐1Summary of 2017 Groundwater Analytical Testing Results

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Addendum 01 Site Inspection Report, Cannon Air Force Base, New Mexico

AFFF Area Location Sample ID

Sample Date

Sample Depth (ft.)

Sample Type

LF03‐MW‐OA CANON14‐GW‐010 05‐Dec‐17 346.0‐346.0 N  0.0086 J 0.042 0.0506 0.096 B

LF04‐MW‐NA CANON14‐GW‐009 03‐Dec‐17 341.0‐341.0 N  0.015 U 0.01 U ND 0.015 U

CANON14‐GW‐011 04‐Dec‐17 346.0‐346.0 N  0.085 J 0.045 J 0.13 J 0.049 Q

CANON‐FD‐GW‐002 04‐Dec‐17 346.0‐346.0 FD 0.087 J 0.042 J 0.129 J 0.046 Q

LF25‐MW‐RB CANON14‐GW‐012 03‐Dec‐17 326.0‐326.0 N  0.015 U 0.01 U ND 0.015 U

MW‐A CANON14‐GW‐001 06‐Dec‐17 321.0‐321.0 N  0.015 U 0.01 U ND 0.0062 B

MW‐B CANON14‐GW‐002 13‐Dec‐17 341.0‐341.0 N  0.015 U 0.023 0.023 0.079 B

MW‐CA CANON14‐GW‐003 14‐Dec‐17 346.0‐346.0 N  24 2.2 26.2 0.84

CANON14‐GW‐004 13‐Dec‐17 341.0‐341.0 N  0.79 2.8 3.59 0.29

CANON‐FD‐GW‐001 13‐Dec‐17 341.0‐341.0 FD 0.75 3.1 3.85 0.28

MW‐E CANON14‐GW‐005 02‐Dec‐17 341.0‐341.0 N  0.015 U 0.01 U ND 0.015 U

MW‐FA CANON14‐GW‐006 12‐Dec‐17 341.0‐341.0 N  0.015 U 0.01 U ND 0.015 U

MW‐GA CANON14‐GW‐007 06‐Dec‐17 341.0‐341.0 N  0.13 0.071 0.201 0.11 B

MW‐H CANON14‐GW‐008 05‐Dec‐17 341.0‐341.0 N  0.041 0.019 J 0.06 J 0.0074 B

MW‐SA CANON14‐GW‐013 14‐Dec‐17 356.0‐356.0 N  0.15 B 1.5 1.65 0.71

MW‐TA CANON14‐GW‐014 13‐Dec‐17 356.0‐356.0 N  0.015 U 0.24 0.24 0.37

MW‐UA CANON14‐GW‐015 13‐Dec‐17 346.0‐346.0 N  0.015 U 0.01 J 0.01 J 0.048 B

MW‐V CANON14‐GW‐016 30‐Nov‐17 361.0‐361.0 N  0.015 U 0.01 U ND 0.015 U

MW‐W CANON14‐GW‐017 01‐Dec‐17 361.0‐361.0 N  0.015 U 0.01 U ND 0.015 U

MW‐X CANON14‐GW‐018 30‐Nov‐17 321.0‐321.0 N  0.015 UJ 0.01 UJ ND 0.015 UJ

Notes:PFAS analysis by Modified USEPA Method 537 using Liquid Chromatography and Tandem Mass Spectrometry1Health Advisory from USEPA Office of Water, 2016a and 2016b, Health Advisories (HAs) for drinking water.

1. If both PFOA and PFOS are detected at or above the detection limit (DL), then the sum of PFOA+PFOS is reported

3. If neither PFOA nor PFOS is detected at or above the DL, then PFOA + PFOS is reported as "ND" representing Not DetectedFD ‐ field duplicate sampleft ‐ feetID ‐ identification

µg/L ‐ micrograms per literN ‐ normal field sampleQ ‐ The analyte is both B qualified because of blank detections and J qualified as an approximate concentration.U ‐ The analyte was analyzed for but was not detected above the reporting limit of detection (LOD).

2USEPA Residential Screening Levels (November 2017a) [https://www.epa.gov/risk/regional‐screening‐levels‐rsls‐generic‐tables‐november‐2017]

PFOS+PFOA = Co‐occurrence of PFOA and PFOS (PFOA+PFOS) in aqueous samples is reported using the following guidelines:

B ‐ The analyte was detected in the sample and an associated blank and the concentration detected in the sample was less than ten times the concentration detected in the blank.

UJ ‐ The reported quantitation limit is approximate and may or may not represent the actual limit of quantitation necessary to accurately and precisely measure the analyte in the sample.

J ‐ The analyte was positively identified and the associated numerical value is the approximate concentration of the analyte in the sample.

2. If only PFOS or only PFOA is detected at or above the DL in groundwater, then the concentration of the detected analyte only is reported

Highlighted cells indicate concentrations exceeding USEPA Health Advisory

14

14

LF25‐MW‐PA

MW‐D

µg/L µg/L µg/L µg/L

EPA RSL Tapwater2: NA NA NA 40Health Advisory1: 0.07 0.07 0.07 NA

Analyte:

Perfluoroo

ctan

esulfonic acid (PFO

S)

Perfluo

rooctano

ic acid (PFO

A)

PFOS+PFOA

Perfluorob

utan

esulfonic acid (PFBS)

Page 1 of 1

Table 2.3‐1Off‐Base Well Locations ‐ New Mexico Office of State Engineer

Site Inspection of Aqueous Film Forming Foam (AFFF) Release AreasAddendum 01 Site Inspection Report, Cannon AFB, Clovis, New Mexico

Map Reference Number1

Well IDNMOSE POD Reference ID

UTM Easting (Zone 13 North)

UTM Northing (Zone 13 North)

Use Total Depth 

(feet bgs)

First Water 

(feet bgs)Construction Date

1 00279 247375 656441.00 3805826.00 Irrigation 375 ‐‐ 1954‐12‐312 00305 216681 656549.00 3805526.00 Irrigation 352 ‐‐ 1981‐12‐313 00279 247373 656447.00 3805224.00 Irrigation 385 ‐‐ 1965‐12‐074 00145 152677 657060.00 3805035.00 Irrigation ‐‐ ‐‐ Unknown5 00145 152682 656764.00 3804527.00 Irrigation 358 ‐‐ 2001‐04‐146 00145 247102 657369.00 3804735.00 Irrigation ‐‐ ‐‐ Unknown7 00145 152680 657067.00 3804433.00 Irrigation ‐‐ ‐‐ Unknown8 00145 152678 657670.00 3804439.00 Irrigation ‐‐ ‐‐ Unknown9 00145 152679 656869.00 3804224.00 Irrigation 368 280 1996‐07‐1410 00164 175129 656478.00 3803213.00 Irrigation 410 ‐‐ 1996‐03‐0711 00145 209101 657080.00 3803628.00 Irrigation ‐‐ ‐‐ Unknown12 00145 152681 657484.00 3803835.00 Irrigation 374 250 1994‐02‐1213 00164 175130 656694.00 3802615.00 Irrigation 390 ‐‐ 1966‐09‐29

14 01070 130453 656894.00 3802615.00Domestic and Livestock

373 298 1996‐10‐19

15 00403 195840 657097.00 3802622.00 Irrigation 440 325 2004‐05‐2116 00403 170641 657173.40 3802570.70 Irrigation 320 ‐‐ Unknown17 00403 170651 657193.00 3802925.00 Dairy 380 260 1992‐05‐1518 00403 170652 657221.70 3802892.00 Dairy ‐‐ ‐‐ Unknown19 00403 190079 657394.00 3803126.00 Irrigation ‐‐ ‐‐ Unknown20 02100 248510 658296.00 3803446.00 Irrigation 398 ‐‐ Unknown21 00158 168103 658296.00 3803446.00 Irrigation 398 ‐‐ 1963‐02‐2822 00158 248512 658496.00 3803446.00 Irrigation ‐‐ ‐‐ Unknown23 00364 183417 658793.00 3803756.00 Irrigation 355 ‐‐ 1963‐12‐2324 00364 183487 658892.00 3803655.00 Irrigation 395 ‐‐ 2003‐06‐1125 00403 196343 657405.00 3802322.00 Irrigation 440 ‐‐ Unknown26 00403 170642 657501.00 3802628.00 Irrigation ‐‐ ‐‐ Unknown27 00438 176383 657109.00 3801818.00 Irrigation 280 ‐‐ 1952‐06‐3028 02450 304855 657881.60 3802255.10 Monitoring 380 350 2016‐12‐1329 00463 204796 657905.00 3802635.00 Irrigation ‐‐ ‐‐ Unknown30 00158 168104 658699.00 3803252.00 Irrigation 407 ‐‐ 1966‐11‐0531 00158 168105 659101.00 3803259.00 Irrigation 415 ‐‐ 1980‐02‐0632 01868 210448 659301.00 3803459.00 Domestic 411 343 2005‐06‐14

33 02359 291974 659521.50 3803504.20Domestic and Livestock

418 ‐‐ 2015‐02‐04

34 00494 248179 659697.00 3803668.00 Irrigation 390 ‐‐ 1969‐03‐3135 00303 187086 657917.00 3801832.00 Irrigation 362 ‐‐ 1954‐06‐3036 00463 247802 658571.30 3802273.90 Irrigation 400 290 2008‐11‐0737 00897 107848 660107.00 3803472.00 Domestic ‐‐ ‐‐ Unknown38 00438 176384 657719.00 3801223.00 Irrigation 260 ‐‐ 1954‐04‐30

Page 1 of 3

Table 2.3‐1Off‐Base Well Locations ‐ New Mexico Office of State Engineer

Site Inspection of Aqueous Film Forming Foam (AFFF) Release AreasAddendum 01 Site Inspection Report, Cannon AFB, Clovis, New Mexico

Map Reference Number1

Well IDNMOSE POD Reference ID

UTM Easting (Zone 13 North)

UTM Northing (Zone 13 North)

Use Total Depth 

(feet bgs)

First Water 

(feet bgs)Construction Date

39 00303 187088 657917.00 3801632.00 Irrigation 379 ‐‐ 1999‐06‐2540 00303 187089 658320.00 3801838.00 Irrigation 386 308 2000‐09‐2841 00303 190095 658421.00 3801739.00 Dairy 375 ‐‐ 1996‐12‐1542 00143 187064 658723.00 3801844.00 Irrigation 365 ‐‐ 1963‐02‐2843 00293 171597 659121.00 3802251.00 Dairy 405 ‐‐ Unknown44 00293 248672 659321.00 3802251.00 Dairy 450 345 2006‐10‐2945 00293 171598 659314.00 3802654.00 Dairy 435 ‐‐ 1965‐10‐0446 00293 171551 659517.00 3802660.00 Dairy 411 300 1999‐05‐1947 00293 171595 659813.00 3803165.00 Dairy ‐‐ ‐‐ Unknown48 00293 182013 659813.00 3803165.00 Dairy 400 ‐‐ Unknown49 00293 255242 659913.00 3803069.00 Dairy 433 372 2010‐08‐1450 00293 171599 659907.00 3803272.00 Dairy 429 335 2004‐10‐2251 00293 171596 660107.00 3803272.00 Dairy 420 ‐‐ Unknown52 00303 187087 658532.00 3801033.00 Irrigation 362 ‐‐ 1965‐10‐1553 00143 187065 658735.00 3801039.00 Irrigation 355 ‐‐ 1964‐12‐3154 00143 247155 659031.00 3801544.00 Irrigation 370 305 2004‐08‐2455 00293 248613 659826.00 3802360.00 Dairy 409 300 1999‐05‐2256 02238 267126 660076.40 3802891.20 Domestic 412 362 2011‐12‐1557 01320 175345 660316.00 3802876.00 Irrigation 426 320 2000‐09‐15

58 00142 171660 659838.00 3801556.00 Irrigation 370 ‐‐ 1963‐02‐28

59 00142 172253 659838.00 3801556.00 Irrigation 380 ‐‐ Unknown

60 00142 175252 659933.00 3801862.00 Irrigation 366 ‐‐ 2000‐06‐16

61 02450 304856 660077.70 3801920.50 Monitoring 340 305 2016‐12‐1462 01334 163137 660330.00 3802071.00 Domestic ‐‐ ‐‐ Unknown63 01520 190040 660632.00 3802373.00 Irrigation 402 ‐‐ 1976‐05‐06

64 01308 159559 661122.00 3802888.00 Irrigation 395 300 2002‐03‐12

65 00366 166743 660337.00 3801868.00 Irrigation 414 ‐‐ 1999‐01‐28

66 01520 190075 660933.00 3802277.00 Irrigation 406 ‐‐ 2003‐06‐2767 00172 247136 659056.00 3799934.00 Irrigation 350 ‐‐ 1963‐07‐31

68 01106 170482 659549.00 3800448.00 Irrigation ‐‐ ‐‐ Unknown

69 01106 170483 659749.00 3800648.00 Irrigation ‐‐ ‐‐ Unknown

70 00142 174285 660140.00 3801260.00 Irrigation 417 ‐‐ 2001‐07‐18

Page 2 of 3

Table 2.3‐1Off‐Base Well Locations ‐ New Mexico Office of State Engineer

Site Inspection of Aqueous Film Forming Foam (AFFF) Release AreasAddendum 01 Site Inspection Report, Cannon AFB, Clovis, New Mexico

Map Reference Number1

Well IDNMOSE POD Reference ID

UTM Easting (Zone 13 North)

UTM Northing (Zone 13 North)

Use Total Depth 

(feet bgs)

First Water 

(feet bgs)Construction Date

71 00366 247867 660337.00 3801668.00 Irrigation 410 330 2004‐08‐04

72 00366 166740 660544.00 3801465.00 Irrigation 380 ‐‐ 1972‐06‐05

73 01654 199510 660740.00 3801873.00 Domestic 376 315 2005‐02‐23

74 00366 166747 660940.00 3801873.00 Irrigation 408 ‐‐ 1999‐01‐21

75 00388 247670 659864.00 3799946.00 Irrigation ‐‐ ‐‐76 01335 163144 660364.00 3800258.00 Domestic 340 289 2000‐12‐01

77 00366 166739 660659.00 3800763.00 Irrigation ‐‐ ‐‐ Unknown

78 00366 166735 660754.00 3800869.00 Irrigation 363 330 1965‐11‐21

79 01333 163131 660954.00 3801069.00 Domestic 373 287 2001‐02‐03

80 00411 170471 661949.00 3801892.00 Irrigation 346 ‐‐ 1966‐01‐31

81 00060 224485 661942.00 3802096.00 Irrigation 373 ‐‐ 2006‐06‐0382 00060 163065 662142.00 3802096.00 Irrigation 367 ‐‐ 1993‐09‐14

83 00366 166736 660564.00 3800058.00 Irrigation 350 ‐‐ 1966‐09‐26

84 00366 166750 660869.00 3800166.00 Irrigation 359 275 1999‐01‐16

85 00763 246677 660863.00 3800568.00 Domestic 341 227 1991‐12‐24

86 00366 166737 661159.00 3800875.00 Irrigation 357 ‐‐ 1969‐01‐06

87 00366 166738 661468.00 3800776.00 Irrigation 363 ‐‐ 1995‐01‐25

88 00366 166749 661761.00 3801081.00 Irrigation 388 274 1999‐01‐14

Notes:Wells identified include only those wells located downgradient of groundwater release areas within 4 miles of the Cannon AFB installation bound1 Map Reference Number pertains to reference numbers shown on Figure 4.2‐1 of this SIRNMOSE = New Mexico Office of State EngineerPOD = Point of DiversionWater well data available from the New Mexico Water Rights Reporting System (NMWRRS) online (http://nmwrrs.ose.state.nm.us/index.html); a

Page 3 of 3

Table 3.0‐1Monitoring Well Construction Details

Site Inspection of Aqueous Film Forming Foam (AFFF) Release AreasAddendum 01 Site Inspection Report, Cannon AFB, Clovis, New Mexico

AFFF Release 

AreaLocation ID

Installation Date

Well Material

Northing EastingGround  

Elevation (ft amsl)

TOC elevation (ft amsl)

Well Depth (ft bgs)

Well Diameter 

(in)

Screen Length 

(ft)

Screen Size (in)

Screen Interval (ft bgs)

MW‐CA 8/16/2017 PVC 3804012.24 655902.16 4266.32 4269.32 350 4 20 0.01 329.7‐349.7

MW‐D 12/16/1984 PVC 3804023.15 655699.10 4265.20 4266.9 355 4 15 0.01 340‐355

MW‐GA 8/27/2017 PVC 3806357.44 655978.71 4279.37 4281.88 355.5 4 35 0.01 320.2‐355.2

LF25‐MW‐PA 2/21/2004 PVC 3806290.62 656074.74 4274.07 4274.73 361.54 4 60 0.01 296.54‐356.54

MW‐SA 8/16/2017 PVC 3804025.09 656050.12 4263.86 4266.3 362 4 40 0.01 321.7‐361.7

MW‐TA 8/8/2017 PVC 3804119.85 656079.96 4263.91 4266.48 362.4 4 35 0.01 327.4‐362.4

MW‐Y 2/6/2019 PVC 3805999.08 656157.13 4271.535 4274.0975 357 4 40 0.01 316.4‐356.4

Notes:AFFF ‐ aqueous film forming foamamsl ‐ above mean sea levelbgs ‐ below ground surfaceft ‐ feetin ‐ inchesPVC ‐ Polyvinyl ChlorideTOC ‐ top of casingCoordinates are displayed in NAD 83 UTM Zone 13 North

14

Table 3.0‐2Groundwater Elevations 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release AreasAddendum 01 Site Inspection Report, Cannon AFB, New Mexico

AFFF Release 

Area

Location IDWell Depth 

(ft bgs)

Ground Surface Elevation (ft amsl)

TOC elevation (ft amsl)

Depth to Groundwater 

(ft btoc)

Groundwater Elevation (ft amsl)

Date Measured

MW‐CA 350 4266.32 4269.32 337.01 3932.31 10/27/2018

MW‐D 355 4265.20 4266.9 330.5 3936.4 10/27/2018

MW‐GA 355.5 4279.37 4281.88 324.42 3957.46 10/22/2018

LF25‐MW‐PA 361.54 4274.07 4274.73 318.62 3956.11 10/23/2018

MW‐SA 362 4263.86 4266.3 334.96 3931.34 10/24/2018

MW‐TA 362.4 4263.91 4266.48 334.17 3932.31 10/23/2018

MW‐Y 357 4271.535 4274.0975 322.09 3952.0075 2/13/2019

Notes:

AFFF ‐ aqueous film forming foam

amsl ‐ above mean sea level

bgs ‐ below ground surface

btoc ‐ below top of casing

ft ‐ feet

TOC ‐ top of casing

14

Page 1 of 1

Table 3.0‐3Off‐Base Sampling Summary

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas  Addendum 01 Site Inspection Report, Cannon Air Force Base, New Mexico

Samples CollectedAnecdotal Use 

DescriptionSample Date Sampling Summary

CANON‐RES748‐01‐SP Domestic 28‐Aug‐18Well is located between two residential properties.  The sample was collected from a spigot located approximately 10 feet from the wellhead (not equipped with sampling port).  Primary, duplicate and MS/MSD samples were collected at this location.  

CANON‐RES730‐01‐SPDomestic, Irrigation, and 

livestock28‐Aug‐18

Sample collected at the residential property.  Resident detailed the piping setup from the well as being underground until it reached the garage, where the sand separator and large storage tank are located. Setup included a drain on the sand‐separator where the well water came into the property, prior to a storage tank.  The drain was opened and sample collected from spigot located before the tank. 

CANON‐RES948‐01‐SPDomestic, Irrigation, and 

livestock28‐Aug‐18

Sample collected at the dairy complex.  Property owner identified location for sampling at dairy storage tank where multiple irrigation wells south of dairy feed water via a single 8" line to the referenced tank.  The closest sampling point was located at the storage tank after the manifold where water is diverted to multiple locations on the dairy.  

CANON‐RES778‐01‐SP Domestic 28‐Aug‐18Sample collected from a spigot located approximately 50’ south of the residence, and approximately 25’ east of the well.  Resident identified that water at the spigot did not pass through holding tanks or any pretreatment prior to the spigot location. 

CANON‐RES738‐01‐SPDomestic, Irrigation, and 

livestock28‐Aug‐18

Sample collected from the residential property from an exterior spigot outside utility room.  The well is located adjacent to the house but was not equipped for direct sampling.  A storage tank was present inside with no sampling ports.  The outdoor spigot was identified as only feasible sampling location.

CANON‐RES1358‐01‐SP Domestic 28‐Aug‐18Sample collected at the residential property.  Wellhead was inaccessible (buried).  Sample was therefore required to be collected from a spigot inside the wellhouse, located approximately 8ft away from the well. 

CANON‐RES650‐01‐SP Dairy 29‐Aug‐18

Sample was collected at the dairy complex from a manifold believed to be up gradient/side gradient of the storage tank.  However, the entire piping system could not be observed during the sampling effort and the sample location was based on limited visual observations (aboveground piping) and description from the dairy operator.  No sample ports were accessible in the pump‐house shed (located immediately adjacent to the sample point), and therefore the sample port behind the central storage tank was utilized (the other two large storage tanks did not have similar piping/sample ports behind them).  The storage tanks were reportedly fed by multiple wells.

CANON‐RES650‐02‐SP Domestic 29‐Aug‐18Sample collected from a spigot located behind the residence in the pool area.  The well vault was inaccessible at the time of sampling due to confined space concerns.    

CANON‐RES650‐03‐SP Domestic 29‐Aug‐18Sample collected at a residential property. The well (no sample port) was situated immediately outside a run‐down shed with the tank and associated piping. Due to the insulation wrapping‐it is unknown if there were sample ports on the tank itself, therefore the closest spigot (on an abondoned/condemned house) was utilized as the sample point.

CANON‐RES692‐01‐SP Domestic 29‐Aug‐18The well at this location fed the dairy office building and a residential property.  The sample was collected from a spigot on the office exterior as the wellhead was inaccessible.  

CANON‐RES725‐01‐SP Domestic 29‐Aug‐18Sample was collected from an exterior spigot located between a residence and maintenance shop.  The well vault was inaccessible and the residence was unoccupied at the time of sampling.  

CANON‐RES717‐01‐SP Domestic 29‐Aug‐18

This well was located in the agricultural field north of the 725 property.  Details indicated a water line ran from this well all the way to the newer 717 residence, over 100 yards away.  This well also represented a confined space situation, but this time was also shown as a hazard due to biological hazards (black widow spiders) in addition to the unknown atmosphere.  Sample collected from outdoor spigot at the 717 residence.  A duplicate sample was also collected at this location.

Page 1 of 2

Table 3.0‐3Off‐Base Sampling Summary

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas  Addendum 01 Site Inspection Report, Cannon Air Force Base, New Mexico

Samples CollectedAnecdotal Use 

DescriptionSample Date Sampling Summary

CANON‐RES682‐01‐SP Domestic and Livestock 29‐Aug‐18One well serviced three properties identified.  Sample was collected from the only operational spigot on the tank located inside the well house.  No other viable sampling points were identified.  

CANON‐RES1397‐01‐SP Domestic 30‐Aug‐18Sample collected at a residential property.  The well distribution system includes a sand separator and large storage tank.  The wellhead/sand separator were not equipped for sampling and therefore the sample was collected from outdoor spigot from shed where the distribution system was housed.

CANON‐RES1369‐01‐SP Domestic 30‐Aug‐18

Sample collected from a spigot on an exterior wall of a residence.  The water that feeds this residence is reportedly from the storage tanks on the dairy property, which are supplied by three wells. Two  wells were equipped with sample ports at the wellhead and were sampled.  The third well was not equipped with sampling ports and therefore a sample was collected from a spigot at the residence.  

CANON‐RES1369‐02‐WHDomestic, Irrigation, and 

livestock30‐Aug‐18  Sample collected from a spigot directly at the wellhead.

CANON‐RES1369‐03‐WHDomestic, Irrigation, and 

livestock30‐Aug‐18 Sample collected from a spigot directly at the wellhead.

CANON‐RES648‐01‐SP Domestic 30‐Aug‐18Sample collected from a residential property. One well services the property; however, the wellhead was not equipped for sampling.  Sample was collected at an outdoor spigot at the home.  

CANON‐RES1461‐01‐SPDomestic, Irrigation, and 

livestock30‐Aug‐18

Water distribution system consisted of three wells that feed into a storage tank system that provided water to a dairy and residence.  No wells were equipped with sample ports. The system had a sand separator prior to the large tanks and therefore the sample was collected from the valve prior to tanks.  

CANON‐RES1495‐01‐SP Domestic 25‐Sep‐18One well was identified at the residential property.  The well was sampled from a spigot located in the well pit in line with pressure tank.  

CANON‐RES546‐01‐SP Domestic 26‐Sep‐18Sample collected at a residential property.  Wellhead was inaccessible for sampling.  Sample was collected from a spigot adjacent to the well pit, after the pressure tank.

CANON‐RES1331‐01‐WH Domestic, Livestock 26‐Sep‐18Sample collected at the dairy complex. The well was fitted with with a spigot directly at the well, and thus the sample was collected prior to the sand separator or storage tanks.

CANON‐RES1349‐01‐SP Domestic 26‐Sep‐18Sample collected at a residential property.  Wellhead was inaccessible for sampling, inside a well pit.  Sample was collected from a spigot adjacent to the well pit, after the pressure tank.

CANON‐RES1591‐01‐SP Domestic 26‐Sep‐18Sample collected at a residential property.  Well was inaccessible for sampling and no sample locations were present in the well house.  Sampling was conducted from outdoor spigot on west exterior of the house.

CANON‐RES1310‐01‐SPDomestic, Irrigation, and 

livestock27‐Sep‐18

Sample collected at a residential property.  No sample ports were identified on the well. An adjacent spigot was non‐operable. Resident indicated the nearest operable sampling port (spigot) was in the barn on the opposite side of the residence.

Page 2 of 2

Table 3.1‐1Summary of Expanded Site Inspection Groundwater Analytical Testing Results

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Addendum 01 Site Inspection Report, Cannon Air Force Base, New Mexico

AFFF Area

Location Sample IDSample 

DateSample 

Depth (ft.)Sample 

Type

LF25‐MW‐PA CANON14‐GW‐022 23‐Oct‐18 346.0‐346.0 N  0.051 0.024 0.075 0.023

CANON14‐GW‐019 27‐Oct‐18 346.0‐346.0 N  22 2 24 0.65

CANON‐FD‐003 27‐Oct‐18 346.0‐346.0 FD 25 2 27 0.66

MW‐D CANON14‐GW‐020 27‐Oct‐18 341.0‐341.0 N  0.96 2.8 3.76 0.18

MW‐GA CANON14‐GW‐021 22‐Oct‐18 341.0‐341.0 N  0.13 0.056 0.186 0.1

MW‐SA CANON14‐GW‐023 24‐Oct‐18 356.0‐356.0 N  0.081 1.6 1.681 0.97

MW‐TA CANON14‐GW‐024 23‐Oct‐18 356.0‐356.0 N  0.015 U 0.34 0.34 0.54

1Health Advisory from USEPA Office of Water, 2016a and 2016b, Health Advisories (HAs) for drinking water.

PFOS+PFOA = Co‐occurrence of PFOA and PFOS (PFOA+PFOS) in aqueous samples is reported using the following guidelines1. If both PFOA and PFOS are detected at or above the detection limit (DL), then the sum of PFOA+PFOS is reported

FD ‐ field duplicate sampleft ‐ feetID ‐ identification

µg/L ‐ micrograms per literN ‐ normal field sampleU ‐ The analyte was analyzed for but was not detected above the reporting limit of detection (LOD).

B ‐ The analyte was detected in the sample and an associated blank and the concentration detected in the sample was less than ten times the concentration detected in the blank.

J ‐ The analyte was positively identified and the associated numerical value is the approximate concentration of the analyte in the sample.

2. If only PFOS or only PFOA is detected at or above the DL in groundwater, then the concentration of the detected analyte only is reported

3. If neither PFOA nor PFOS is detected at or above the DL, then PFOA + PFOS is reported as "ND" representing Not Detected

2USEPA Residential Screening Levels (November 2017a) [https://www.epa.gov/risk/regional‐screening‐levels‐rsls‐generic‐tables‐november‐2017]

Analyte:

Perfluoroo

ctanesulfonic acid (P

FOS)

Perfluoroo

ctanoic acid (P

FOA)

PFOS+PFOA

Perfluorob

utanesulfonic acid (P

FBS)

Health Advisory: 0.07 0.07 0.07 NAEPA RSL Tapwater¹: NA NA NA 40

µg/L µg/L µg/L µg/L

Highlighted cells indicate concentrations exceeding USEPA Health Advisory

14

MW‐CA

Table 3.1‐2Summary of Off‐Base Analytical Testing Results

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Addendum 01 Site Inspection Report, Cannon Air Force Base, New Mexico

Sample IDSample 

DateSample 

Type

CANON‐RES1310‐01‐SP‐09272018 27‐Sep‐18 N  0.00413 U 0.00413 U ND 0.00413 U

CANON‐RES1331‐01‐WH‐09262018 26‐Sep‐18 N  0.00413 U 0.00413 U ND 0.00413 U

CANON‐RES1349‐01‐SP‐09262018 26‐Sep‐18 N  0.00413 U 0.00413 U ND 0.00413 U

CANON‐RES1358‐01‐SP‐08282018 28‐Aug‐18 N  0.00435 U 0.00435 U ND 0.00435 U

CANON‐RES1369‐01‐SP‐08302018 30‐Aug‐18 N  0.00424 U 0.00424 U ND 0.00424 U

CANON‐RES1369‐02‐WH‐08302018 30‐Aug‐18 N  0.00431 U 0.00431 U ND 0.00431 U

CANON‐RES1369‐03‐WH‐08302018 30‐Aug‐18 N  0.0041 U 0.0041 U ND 0.0041 U

CANON‐RES1397‐01‐SP‐08302018 30‐Aug‐18 N  0.00413 U 0.00413 U ND 0.00413 U

CANON‐RES1461‐01‐SP‐08302018 30‐Aug‐18 N  0.00417 U 0.00417 U ND 0.00417 U

CANON‐RES1495‐01‐SP‐09252018 25‐Sep‐18 N  0.0042 U 0.0042 U ND 0.0042 U

CANON‐RES‐DUP‐01‐09252018 25‐Sep‐18 FD 0.00417 U 0.00417 U ND 0.00417 U

CANON‐RES1591‐01‐SP‐09262018 26‐Sep‐18 N  0.00417 U 0.00793 J 0.00793 J 0.00862

CANON‐RES546‐01‐SP‐09262018 26‐Sep‐18 N  0.00427 U 0.00427 U ND 0.00427 U

CANON‐RES648‐01‐SP‐08302018 30‐Aug‐18 N  0.01 0.0155 0.0255 0.0103

CANON‐RES650‐01‐SP‐08292018 29‐Aug‐18 N  1.11 0.539 1.649 0.21

CANON‐RES650‐02‐SP‐08292018 29‐Aug‐18 N  0.404 0.267 0.671 0.137

CANON‐RES650‐03‐SP‐08292018 29‐Aug‐18 N  0.00442 U 0.00442 U ND 0.00442 U

CANON‐RES682‐01‐SP‐08292018 29‐Aug‐18 N  0.0042 U 0.0042 U ND 0.0042 U

CANON‐RES692‐01‐SP‐08292018 29‐Aug‐18 N  0.00427 U 0.00427 U ND 0.00427 U

CANON‐RES717‐01‐SP‐08292018 29‐Aug‐18 N  0.0042 U 0.0042 U ND 0.0164

CANON‐FD‐02‐08292018 29‐Aug‐18 FD 0.00417 U 0.00417 U ND 0.0147

CANON‐RES725‐01‐SP‐08292018 29‐Aug‐18 N  0.0041 U 0.0041 U ND 0.0145

CANON‐RES730‐01‐SP‐08282018 28‐Aug‐18 N  0.00413 U 0.00413 U ND 0.00413 U

CANON‐RES738‐01‐SP‐08282018 28‐Aug‐18 N  0.00463 U 0.00463 U ND 0.0111

µg/L µg/L µg/L µg/L

NA NA NA 40NA

Perfluoroo

ctanesulfonic acid (P

FOS)

Perfluoroo

ctanoic acid (P

FOA)

PFOS+PFOA

Perfluorob

utanesulfonic acid (P

FBS)

0.07 0.07 0.07

Page 1 of 2

Table 3.1‐2Summary of Off‐Base Analytical Testing Results

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Addendum 01 Site Inspection Report, Cannon Air Force Base, New Mexico

Sample IDSample 

DateSample 

Typeµg/L µg/L µg/L µg/L

NA NA NA 40NA

Perfluoroo

ctanesulfonic acid (P

FOS)

Perfluoroo

ctanoic acid (P

FOA)

PFOS+PFOA

Perfluorob

utanesulfonic acid (P

FBS)

0.07 0.07 0.07

CANON‐RES748‐01‐SP‐08282018 28‐Aug‐18 N  0.00435 U 0.00435 U ND 0.00435 U

CANON‐FD‐01‐08282018 28‐Aug‐18 FD 0.00431 U 0.00431 U ND 0.00431 U

CANON‐RES778‐01‐SP‐08282018 28‐Aug‐18 N  0.00439 U 0.00439 U ND 0.00439 U

CANON‐RES948‐01‐SP‐08282018 28‐Aug‐18 N  0.0953 0.0506 0.1459 0.0641

1Health Advisory from USEPA Office of Water, 2016a and 2016b, Health Advisories (HAs) for drinking water.

Highlighted cells indicate concentrations exceeding USEPA Health AdvisoryPFOS+PFOA = Co‐occurrence of PFOA and PFOS (PFOA+PFOS) in aqueous samples is reported using the following guidelines1. If both PFOA and PFOS are detected at or above the detection limit (DL), then the sum of PFOA+PFOS is reported2. If only PFOS or only PFOA is detected at or above the DL in groundwater, then the concentration of the detected analyte only is reported3. If neither PFOA nor PFOS is detected at or above the DL, then PFOA + PFOS is reported as "ND" representing Not DetectedFD ‐ field duplicate sampleft ‐ feetID ‐ identification

J ‐ The analyte was positively identified and the associated numerical value is the approximate concentration of the analyte in the sample.µg/L ‐ micrograms per literN ‐ normal field sampleU ‐ The analyte was analyzed for but was not detected above the reporting limit of detection (LOD).

B ‐ The analyte was detected in the sample and an associated blank and the concentration detected in the sample was less than ten times the concentration detected in the blank.

2USEPA Residential Screening Levels (November 2017a) [https://www.epa.gov/risk/regional‐screening‐levels‐rsls‐generic‐tables‐november‐2017]

Page 2 of 2

Table 4.0‐1 Conceptual Site Model:  Installation‐Wide Summary 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Addendum 01 Site Inspection Report, Cannon AFB, Clovis, New Mexico 

Page 1 of  3 

Facility Profile  Physical Profile  Release Profile  Land Use and Exposure Profile  Ecological Profile 

Installation Description/History:   Years of operation: 1942 to the present.   Size: Approximately 3,789 acres.   Location: Eastern New Mexico, approximately 7 miles southwest of the City of Clovis, in Curry County, New Mexico. 

 Layout: The installation is comprised of two perpendicular active runways in the central and southwestern portions; maintenance, support, and operational facilities west of the central runway/flightline; supplemental hangars and apron areas in the south‐central region; a wastewater treatment plant to the east; and, a golf course and residential and service facilities in the northwestern portion (HGL, 2015). 

 History: Cannon AFB dates to 1929 when Portair Field was established as a civilian passenger terminal.  The Army Air Corps took control of the civilian airfield in 1942 and it became known as the Clovis Army Air Base.  The installation was renamed Clovis Army Air Field in early 1945, where flying, bombing, and gunnery classes continued until the installation was deactivated in May 1947. The installation was reassigned to the TAC and formally reactivated as Clovis AFB in 1951, and subsequently renamed Cannon AFB in 1957 (Versar, 2013).   

 Current Mission: Home to the 27th SOW where it conducts infiltration/exfiltration, combat support, tilt‐rotor operations, helicopter aerial refueling, close air support, unmanned aerial vehicle operations, non‐standard aviation, and other special missions. It directs the deployment, employment, training, and planning for squadrons that operate the AC‐130W, MC‐130J, CV‐22B, C‐146A, U‐28A, MQ‐1, MQ‐9, and provides operational support to flying operations (Versar, 2013). 

   

Topography: The installation is situated in the Southern High Plains Physiographic Province near the center of the Llano Estacado subprovince. This area is a nearly flat plain sloping gently (10 to 15 feet per mile) to the east and southeast. In the vicinity of Cannon AFB, elevations range from 4,250 to 4,350 feet above mean sea level (AECOM, 2011). 

Vegetation:  Vegetation at Cannon AFB is typical of semiarid, short grass prairies (Plains‐Mesa grassland) and is limited by water availability (CH2MHill, 1983).   

Much of the Llano Estacado (80‐90%) has been tilled for agriculture, with farmers producing cotton, corn, and wheat under dryland agriculture or irrigated with water pumped from the Ogallala Aquifer (USEPA, 2006). 

Surface Water:  Permanent surface water streams are non‐existent in the Cannon AFB vicinity. Running Water Draw, located approximately 10 miles north of the installation, is the nearest drainage feature and is dry for much of the year. 

Historically, surface runoff at Cannon AFB has drained into four natural, ephemeral, playas. Two of the northern playas were converted into plastic‐lined golf course ponds. The southern playa, known as South Playa Lake, occupies approximately 9 acres south of the intersection of the main jet runways and is approximately 15 feet deep. Since 1943, stormwater runoff from the flightline has collected in this playa where it either evaporates or percolates into the soil. The northern playa, known as North Playa Lake, was bermed on the north, west, and south sides with topsoil and concrete debris. It covers approximately 13 acres and received treated effluent from the former sewage lagoons (AECOM, 2011). 

Soils:   Soils at Cannon AFB are predominantly fine sandy loams of the Amarillo series, which consists of very deep, well drained, moderately permeable soils derived from loamy eolian sediments from the Blackwater Draw Formation of the Pleistocene (United States Department of Agriculture [USDA], 2017). 

Geology:  The subsurface geology of the Southern High Plains aquifer at Cannon AFB includes the Chinle, Ogallala, and Blackwater Draw Formations. 

 The Chinle Formation of Triassic Age forms the bottom of the unconfined Southern High Plains Aquifer in this area, and consists primarily of clay with some intermixed sand and silt, and ranges in thickness from 0 to 400 feet in eastern New Mexico. 

 The Ogallala Formation of Tertiary Age is the main water‐yielding unit of the Southern High Plains Aquifer and lies unconformably atop the upper unit of the eastward‐dipping Chinle Formation. The Ogallala Formation consists of eolian sand and silt and fluvial and lacustrine sand, silt, clay, and gravel, and ranges in thickness from 30 to 600 ft in eastern New Mexico and west Texas. 

 The Blackwater Draw Formation of Quaternary Age generally overlies the Ogallala Formation at Cannon AFB. The Blackwater Draw Formation is 

Contaminants of Potential Concern: PFAS are the contaminants of potential concern for this investigation.  Fuel related compounds and chlorinated solvents are historical site contaminants.  

Media of Potential Concern:  Soil, sediment, surface water, and groundwater. Confirmed AFFF Releases:   Former FTA No. 2: Possible AFFF use from 1970 to 1974 in unlined FTA with an unknown volume of AFFF used for firefighting training.  PFOS and PFOA were detected in both surface and subsurface soil at concentrations below the calculated RSL.  PFBS was not detected.  

Former FTA No. 3: Possible AFFF use from 1970 to 1974 in an unlined FTA with an unknown volume of AFFF used for firefighting training.  PFOS was detected above the calculated RSL in surface soil but was not detected in subsurface soil.  PFOA was detected below the calculated RSL in the surface soil but not detected in subsurface soil.  PFBS was not detected.   

Former FTA No.4: Possible AFFF use from 1974 to 1995 with an unknown volume of AFFF used for firefighting training.  PFOS was detected above the calculated RSL in surface soil but was not detected in subsurface soil.  PFOA was detected at concentrations below the calculated RSL in surface and surface soil.  PFBS was detected in subsurface soil at concentrations below the calculated RSL.   

Hangar 119 and 133: Accidental releases of AFFF inside the hangars likely discharged to grassy areas outside the hangars.  PFOS was detected above the calculated RSL in surface soil samples and below the calculated RSL in subsurface samples (28 to30 feet bgs).  PFOA and PFBS were detected below the calculated RSL in surface and subsurface soil samples.   

Former Sewage Lagoons: Operated between 1966 and 1998; during operation, lagoons received any AFFF that entered the sanitary sewer system.  Evidence of AFFF releases in hangars during this time period, which may have entered the sanitary sewer system and been routed to the former sewage lagoons.  Only subsurface soil sampling was conducted as part of SI activities as surface material was fill material.  PFOS was detected above the calculated RSL in subsurface soil.  PFOA and PFBS were detected below the calculated RSL in subsurface soil. 

North Playa Lake Outfall: Any wastewater collected at the WWTP containing AFFF would be passed on to North Playa Lake. Several releases of AFFF from hangars entered the sanitary sewer system and were routed to the WWTP. PFOS was detected in sediment samples at concentrations below the calculated RSL.  PFOA and PFBS were not detected in sediment.  PFOS and PFOS+PFOA were detected/calculated in surface water at concentrations exceeding the USEPA HA value (0.07 µg/L).  PFOA was detected in surface water at concentrations below the USEPA HA value.  PFBS was detected in surface water at concentrations below the USEPA Tap Water RSL. 

South Playa Lake Outfall: Any stormwater or wastewater containing AFFF that enters storm drains near the flightline is routed to South Playa Lake. Several releases of AFFF from hangars entered nearby storm drains and 

Current Land Use: Occupied by Cannon AFB. 

Future Land Use:  Land use is not expected to change in the future. 

Potential Receptors:  Potential receptors associated with current and future land use include USAF personnel and residents, grounds maintenance workers, utility workers, construction workers. 

Recreational users of Whispering Winds Golf Course. 

Off‐base groundwater users located downgradient of PFAS impacted groundwater identified at the southeastern area of the base. 

Potential Ecological Receptors:  Inland and aquatic plant species, reptiles, birds, soil invertebrates, and mammals that inhabit or migrate through the installation. 

Threatened and Endangered Species:  Threatened species that were identified in Curry County and may exist at Cannon AFB include the following:  Lesser prairie‐chicken (Tympanuchus pallidicinctus) – under review. 

Table 4.0‐1 Conceptual Site Model:  Installation‐Wide Summary 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Addendum 01 Site Inspection Report, Cannon AFB, Clovis, New Mexico 

Page 2 of  3 

Facility Profile  Physical Profile  Release Profile  Land Use and Exposure Profile  Ecological Profile 

AFFF Use:  AFFF containing PFAS was used for firefighting training activities, testing of firefighting equipment, extinguishing petroleum fires, and in fire suppression systems at several installation buildings. 

Fourteen potential AFFF release areas were recommended for SI at Cannon AFB:  Former FTA No. 2;  Former FTA No. 3;  Former FTA No. 4;  Hangars 119 and 133;  Former Sewage Lagoons;  North Playa Lake Outfall;  South Playa Lake Outfall;   Whispering Winds Golf Course Outfall.  Hangar 109;  Active FTA;  Landfill #4;  Perimeter Road Fuel Spill  Flightline Crash Areas; and,  Basewide Groundwater 

 

composed primarily of eolian sand deposits, and ranges in thickness from 0 to 80 feet in eastern New Mexico. 

 A caliche layer is typically present in the unsaturated zone of the Blackwater or Ogallala Formations in New Mexico. 

Hydrogeology:  The lower portion of the Ogallala Formation is the primary regional aquifer for both potable and irrigation water. 

The Ogallala Aquifer is part of the Southern High Plains Aquifer that extends across parts of southeast New Mexico and northwest Texas, which in turn is part of the larger High Plains Aquifer that extends continuously from Wyoming and South Dakota into New Mexico and Texas. 

Cannon AFB is underlain by the portion of the Ogallala Aquifer designated the Curry County Underground Water Basin. The Ogallala Aquifer is a water table, or unconfined, aquifer with the underlying Chinle redbeds serving as the basal confining layer in eastern New Mexico. 

At Cannon AFB, the depth to groundwater is approximately 300 feet bgs.  The saturated thickness in 1990 ranged from 93 to 143 feet, but continues to decrease.  Groundwater flow is generally from northwest to southeast (FPM, 2014).  

Depth to water measurements collected in November and December 2017 as part of the SI ranged from 287.78 feet below top of casing (btoc) in monitoring well MW‐X located in the southwest portion of the installation to 351.80 feet btoc in monitoring well MW‐H located on the south side of the former sewage lagoon.  The calculated groundwater elevations ranged from 3981.45 feet above mean sea level (amsl) in MW‐X to 3929.38 feet amsl at MW‐H.   

Meteorology:  Average annual rainfall is 17.9 inches/year in Clovis, New Mexico.  Average number of days with measurable rainfall is 54 days.    Average high temperature of 92°F occurs in July, while an average low of 23.4°F occurs in January. 

were routed to the lake.  PFOS and PFOA were detected in both surface and subsurface soil at concentrations below the calculated RSL.  PFBS was not detected in surface or subsurface soil. 

Whispering Winds Golf Course Outfall: The golf course began receiving effluent from the WWTP plant in approximately 2002. Currently, the golf course stores effluent in a storage tank on the eastern portion of the course.  Effluent is regularly used for golf course irrigation and filling the two golf course ponds.  A release of AFFF into any of the hangar floor trenches or fire station stalls would be routed through the WWTP. As such, effluent from the WWTP used at the golf course may contain AFFF.  PFOS was detected in sediment samples at concentrations below the calculated RSL.  PFOA and PFBS were not detected in sediment.  PFOS and PFOS+PFOA were detected/calculated in surface water at concentrations below the USEPA HA value (0.07 µg/L).  PFOA and PFBS were not detected in surface water.   

Hangar 109: A recent release of AFFF inside the hangar/mechanical rooms resulted in AFFF being released outside the hangar and draining to grassy areas outside the hangar.  PFOS was detected above the calculated RSL in surface soil but was not detected in subsurface soil samples.  PFOA and PFBS were detected below the calculated RSL in the surface soil sample and was not detected in the subsurface soil sample.  

Landfill No. 4: Landfill is located immediately north of the North Playa Lake.  Cover was irrigated using water from North Playa Lake where wastewater from WWTP (potentially including AFFF) was discharged.  Groundwater was sampled downgradient of the landfill (monitoring well LF04‐MW‐Na).  No PFOS, PFOA, or PFBS were detected. 

Active FTA: Lined evaporation pond located south of the FTA where AFFF/water mix is collected and left to evaporate has been repaired in the past.  Any damage to liner would result in AFFF being released to environment.  In addition, an extreme flood event in May 2015 likely resulted in the evaporation pond overflowing, allowing residual AFFF to infiltrate into surrounding soil.  PFOS was detected above the calculated RSL in surface soil and below the calculated RSL in subsurface soil.  PFOA was detected in surface soil at concentrations below the calculated RSL and was not detected in subsurface soil.  PFBS was not detected in surface or subsurface soil. 

Perimeter Road Fuel Spill: AFFF was sprayed from crash fire trucks onto a fuel spill associated with an overturned tanker trunk on the southeast side of Perimeter Road.  No PFOS, PFOA or PFBS were detected in surface or subsurface soil. 

Flightline Crash Areas: Cannon AFB Fire Department noted three separate crash areas along the flightline where AFFF was released during crash response activities.  No soil sampling was conducted relative to the crash sites.  Results of groundwater monitoring from locations downgradient of the crash sites is summarized below. 

Basewide Groundwater:  Groundwater was evaluated for all identified AFFF release areas; however, since groundwater at Cannon AFB is regulated basewide by NMED rather than specific to individual areas of 

Table 4.0‐1 Conceptual Site Model:  Installation‐Wide Summary 

Site Inspection of Aqueous Film Forming Foam (AFFF) Release Areas Addendum 01 Site Inspection Report, Cannon AFB, Clovis, New Mexico 

Page 3 of  3 

Facility Profile  Physical Profile  Release Profile  Land Use and Exposure Profile  Ecological Profile 

concern, a separate AFFF release area (Release Area 14) was identified for evaluating the presence of PFAS in basewide groundwater.   PFOS, PFOA, and/or PFBS were detected in groundwater at 11 existing basewide monitoring wells. PFOS, PFOA and PFOS+PFOA exceeded the USEPA HA value (0.07 µg/L) in six monitoring wells: MW‐Ga and LF25‐MW‐Pa located southeast of the sewage lagoon area; and at monitoring wells MW‐Ca, MW‐D, MW‐Sa and MW‐Ta located in the southeast corner of the installation.  Confirmation sampling was completed for MW‐Ga, LF25‐MW‐Pa, MW‐Ca, MW‐D, MW‐Sa, and MW‐Ta. PFOS, PFOA and/or PFOS+PFOA exceeded the USEPA HA value (0.07 µg/L) again in all six monitoring wells.   

Analytical results from groundwater sampling of newly installed monitoring well (MW‐Y) confirmed the presence of PFOS, PFOA and PFOS+PFOA.  The concentrations of PFOS and PFOS+PFOA exceeded the USEPA HA value (0.07 µg/L).  The monitoring well is located at the installation boundary, downgradient (southeast) of the former sewage lagoon area.  

Off‐Base Groundwater:  25 water samples were collected from off‐base properties, downgradient of Cannon AFB where groundwater was used as a source of drinking water.  PFOS, PFOA and/or PFOS+PFOA exceeded the USEPA HA value (0.07 µg/L) in three sample locations.   

Primary Release Pathways:  Release or application of AFFF to the ground at potential source areas.  Infiltration of PFAS deeper into the soil column over time and reaching groundwater. 

AFFF washed into drainage, stormwater, and sewer systems. Secondary Release Pathways:  Irrigation utilizing water from the WWTP.   Irrigation utilizing impacted groundwater  