fine movement occupancy sensor for hvac and lighting control
DESCRIPTION
360 degree Ceiling mount PIR presence sensor / occupancy sensor - Dual channel for HVAC and lighting controlTRANSCRIPT
training presence Control PRO IR Quattro COM1/COM2
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
Control PRO System
presence control PRO IR quattro HD presence control PRO HF 360presence control PRO DUAL HF
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
Control PRO System
fire control PROair control PRO
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
mounting
(1) Output module
(2) Sensor module
(10) Flush mounting box
(11) Surface mounting box
(IP 54)
(12) Lock mechanism
IP 54
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
presence Control PRO IR Quattro
• 1 pyro infrared sensor
• 1760 switching zones for very precise coverage
• room-typical, square detection zone
• Tangential: 7 x 7 m
• Radial: 5 x 5 m
• Presence: 4 x 4 m
• mechanical reach setting
• IP 20
• Accessories: surface mounting box (IP 54), flush mounting box with holding clamps, remote control RC3, remote control RC4, remote control RC5,
mounting height 3 m
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
functions IR Quattro COM1
(3) bottom side sensor module
(4) dip-switches
• Normal-/Test-mode
• full-/semiautomatic
• momentary switch/switch
• switch ON/ON-OFF
(5) twilight setting
(6) time setting switch contact 1
(9) mechanical reach setting
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
(5) twilight setting
• 10 – 1000 lux with 6 typical room situations (stepless) (eg. 1 = corridor ca. 100 Lux)
• left stop night mode
• right stop day mode
(6) time setting switch contact 1
• depending on occupancy and light level
• 30 sec. – 30 min.
• impulse modeeg. for stairway automats
• IQ-modeintelligent selflearning time setting dependingthe specific pattern of room use
functions IR Quattro COM1
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
functions IR Quattro COM1
(4) Dip-switches
• Normal-/Test-mode
Test-mode:
- load independent test-mode - 8 sec. ON- without connected load adjustable- blue LED blink at detection - to proof functionality and detection zone
Normal-mode:
- works depending on settings by trimpods and dip-switches
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
functions IR Quattro COM1
(4) dip-switches
• full-/semiautomatic
fullautomatic:
- automatic ON / automatic OFF depending on occupancy and light level
- manual control possible
semiautomatic:
- manual ON / automatic OFF
- manual OFF possible
- after using a switch lights switch ON and sensor mode starts depending on trimpod and dip switch setting
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
functions IR Quattro COM1
(4) dip-switches
• momentary switch/switch
momentary switch:
- use with external momentary switch
switch:
- use with external switch
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
functions IR Quattro COM1
(4) dip-switches
• ON/ON-OFF
ON:
- no manuall OFF possible
- push on switch restarts run down time
ON-OFF:
- manual ON & OFF possible
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
functions IR Quattro COM1
(9) mechanical reach setting
• 7 „orientation points“ on bottom side of the sensor
• at a mounting height of 3 m the number chosen with the trimpod means the length of the square side for tangential detection
• „translation table“ for different mounting heights and radial respectively presence detection in the owners manual
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
functions IR Quattro COM1
(3) bottom side sensor module
(4) dip-switches
• Normal-/Test-mode
• full-/semiautomatic
• momentary switch/switch
• switch ON/ON-OFF
(5) twilight setting
(6) time setting switch contact 1
(7) time setting switch contact 2 (PF)
(8) time delay switch contact 2
(9) mechanical reach setting
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
functions IR Quattro COM2
(7) time setting switch contact 2 (PF)
- run down time of the hvac Schaltkontakts von 1 Min. bis 2 Stunden
(8) time delay switch contact 2 (PF)
- switch-on delay switch contact 2 from 30 sec. to 10 min.
- room observation
- only if the room is used really the hvac contact will be switched
- a short look into the room will be ignored
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
crosslinking of the sensors
Master/Slave:
- Slaves only report occupancy to the Master
- only the Master switches the load
- switching only depending on the Master settings
Master/Master:
- all Masters report occupancy to each other
- every Master switches ist own load depending on ist own settings
Master: load connected
Slave: no load connected
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
functions remote control RC3 (service)
reach setting HF/US sensors
Reset to trimpod & dip settings
Teach IN
twilight setting
Reduce sensitivity
time setting switch contact 2 (hvac)
time setting switch contact 1 (light)
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
functions remote control RC4 (DIM)
Reset to trimpod & dip settings
4 hours manual override
set dimming level
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
functions remote control RC5 (DALI)
Reset to trimpod & dip settings
Save/load scene
set dim level
Manual override
set dim level
Manual override
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
USP´s
precise coverage by 1760 switching zones
IR Quattro
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
USP´s
very precise coverage by more than 4000 switching zones
IR Quattro HD
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
USP´s
coverage of different presence detectors (presence detection area)
STEINEL IR Quattro STEINEL IR Quattro HD standard motion detector
Busch Jäger PräsenzTech
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
USP´s
more than 4000 switching zones for very precise coverage
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
USP´s
more than 4000 switching zones for very precise coverage
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
USP´s
roomtypical square detection
7m
7m
detection reach (mounting height 3m):
- squares: Steinel IR Quattro- circles: competitors presence detector
- inner area: presence detection
Steinel: 4x4m detection squarecompetitor: circle Ø 4m
- middle area: radial detectionSteinel: 5x5m detection squarecompetitor: circle Ø 6m
- outer area: tangential detectionSteinel: 7x7m detection squarecompetitor: circle Ø8m
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
USP´s
roomtypical square detection
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
USP´s
roomtypical square detection
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
auch Bereiche innerhalb der einzelnen Bürosnicht erfasst
USP´s
roomtypical square detection
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
USP´s
mechanical reach setting
-
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
USP´s
tangentiale Erfassung
radiale Erfassung
Präsenzerfassung
- Reduzierung auf den reinen - alle Erfassungsbereiche werden elektronischPräsenzbereich runtergeregelt, so dass der Präsenzbereich
- radiale und tangentiale Erfassung auf Ø 2m eingeschränkt wirdwerden "abgeschnitten" - radiale und tangentiale Erfassung bleibt vorhanden!
reduziert auf 4 x 4 m reduziert Ø 4m
mechanical reach setting
reduced to 4x4m reduced to Ø 4m
tangential detection
radial detection
presence detection
- reduced to presence detection only
- radial & tanegntial detection are „cut off“
- all detection zones are sized down detection only
- radial & tanegential detection are „cut off“
Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904
Ausblick
sensor modules:
IR Quattro (1 Pyro)
IR Quattro HD (4 Pyros)
HF 360° (HF bar antenna)
DUAL HF (2 HF Patch antennas)
AirControl
FireControl
output modules:
COM1 (1 Relais)
COM2 (1+1 PF Relais)
DIM (1-10V)
KNX
DALI
Impulser
flat surface mounting version
Accessories: surface mounting adapter (IP 54), surface mounting adapter KNX/DALI, flush-mounting adapter (with holding clamps), service remote control, DIM remote control, DALI remote control, protection basket