  • Finnigan™ GasBench II

    Analyze • Detect • Measure • Control™

    Universal On-line Gas Preparation

    and Introduction System for

    Isotope Ratio MS

    m a s s s p e c t r o m e t r y

  • Universal O

    n-line Gas Preparation

    and Introduction System for

    Isotope Ratio MS

    • Multiple loop injection leads to high precision• Automation leads to high sample throughput• High sensitivity results in low sample consumption• GC separation delivers pure analyte from gas mixtures• Automatic range recognition and autodilution leads to the

    largest dynamic range of sample size• Extreme flexibility leads to very high versatility

    The Finnigan GasBench II is an innovative solution for high precision on-line isotope and molecular ratiodetermination of headspace samples, including water equilibration, carbonates, and atmospheric gases(e.g. CO2, O2/N2). The precision and accuracy of the dual viscous flow inlet system are achieved usingmodern “continuous flow“ techniques.

    The Finnigan GasBench II is not only an alternative to dual inlet system techniques but it significantlyextends the practice of isotope ratio mass spectrometry (IRMS).

    Finnigan™ GasBench IIUniversal on-line gas preparation and introduction system for isotope ratio MS

    Finnigan™ GasBench IIOn-line gas preparation

    Multiple loop injection

  • The range of applications includes, but isnot limited to:• D/H in water through equilibration with H2/Pt

    • 18O/16O in water through equilibration with CO2• 18O/16O and 13C/12C from carbonates• 13C/12C of dissolved inorganic carbon (DIC)• 13C/12C and 18O/16O of CO2 in air

    • 18O/16O and 17O/16O of O2 in air and water

    • 15N/14N of N2 in air

    In combination with the PostConcryotrapping options or the PreCon:• 13C/12C of CO2 in air (sub-ambient concentrations)

    • 15N/14N and 18O/16O of N2O in air (300 ppb)

    • 13C/12C of CH4 in air (1.7 ppm)

    • 15N/14N and 18O/16O of N2O

    • 15N/14N and 18O/16O of nitrate using theSigman technique

    • 15N/14N of N2 from micro-preparation systems

    Flexible design allows use with lasers andElemental Analyzers• Sampling of CO2 and SO2 from laser

    combustions and decarbonation• Post-combustion concentration of CO2, N2, SO2

    from elemental analyzers

    Due to the versatility of the Finnigan GasBench II thelist of gas species, isotope ratios, and experimentsthat can be performed with the Finnigan GasBench IIis constantly being extended.

    Wide rangeof applications

    Finnigan GasBench II Applications

  • He+H2O He

    Water Removal 1

    He+H2O He

    Water Removal 2

    100 µL

    DELTAplusXPMAT 253

    Autosampler(96 Vials) He GC Column

    Vent

    Valco6-Port

    He

    Active Open Split

    He +CO2+H2+N2+O2+N2O

    1

    2

    34

    5 3 6

    The Finnigan GasBench II consists of a user-programmable autosampler (1), a gassampling system (2), a maintenance-freewater removal system (3), a loop injectionsystem (4), an isothermal gas chromatograph(GC) (5), an active open split interface (6), areference gas injection system with threereference ports (7), and one or two optionalLN2 traps for cryofocusing.

    The autosampler can be equipped witha variety of sample trays. A preciselythermostated sample tray is used forcarbonates and water equilibration.

    The gas sampling system includes atwo port needle which adds a gentle flow ofHe into the sample vial, thus diluting anddisplacing sample gas. Water is removedfrom the sample gas through diffusion traps.The loop injector aliquots the sample gasonto the GC column, which separates themolecular species. The reference gasinjection system allows accuratereferencing of each sample aliquot toisotopic standards. The system is designedfor unattended measurements with highthroughput, ensuring high productivityand high reliability.

    The Finnigan GasBench II can be usedfor the isotopic characterization of CO2,N2O, O2 or N2 between 200 nmol and 20µmol of total sample size. The CO2 can be inthe original gas sample (air or breath), bereleased through a preparation step(carbonates, DIC) or be added to the originalliquid sample (water-CO2 equilibration).

    GasBench Scheme

    Universal O

    n-line Gas Preparation

    and Introduction System for

    Isotope Ratio MS

    Single sample acquisition with 10 replicates

    Technical Details

  • The Finnigan GasBench II allows theprecision and accuracy of the dual inletsystem to be realized on a CF-IRMS system.The dual inlet principle of repetitivemeasurements of sample and standard gasis not only retained, it is generalized. Thesample volume is the sample vial (insteadof a metal bellows), and the reference gasvolume is a pressurized gas tank. Referencegas pulses are introduced under computer

    control into to the carrier gas stream fromthe reference injection system.

    The sample gas is entrained in He,which allows GC separation and facilitatesfractionation-free viscous flow transport ofthe sample aliquots. In a typical experiment,ten aliquots of the sample will be takenfrom the sample vial, dried and cleaned on-line, and measured against reference gaspulses. The sample consumption is much

    lower than for the dual inlet system, whilecomparable precisions are achieved,including an analysis of internalreproducibility.

    Comparison to the “classical”Dual Inlet SystemDuring a dual inlet measurement, sampleand reference gases confined in variablevolumes close to the ion source aresampled alternately and repeatedly througha changeover valve. This measurementstrategy leads to high analytical precisionand accuracy. Internal reproducibility of the

    individual measurements is a commonlyused measure of analytical quality which,up to now, has been missing from CF-IRMSinlet systems. The drawbacks of the dualinlet system include off-line samplepreparation and purification, ineffectiveuse of the sample gas, lengthy dataacquisitions, and cost.

    The GasBench Principle

    The combination of “Repetitive Loop Injection” and Reference GasInjection is a generalization of the analytical procedure of sample-standard comparisons performed with a dual viscous flow inlet system.

  • H2/H2O and CO2/H2Oequilibration for δD and δ18Odetermination of waterThe measurement of the D/H and 18O/16Oratios of water is one of the most importantapplications of isotope ratio massspectrometry. There is a very diverse rangeof applications ranging from studies ofvariations in natural isotope abundance inthe hydrologic cycle, to authenticity controlon beverages, to metabolic studies using D- or 18O-enriched tracers in humans andanimals. This extreme range of sampletypes demands a flexible general purposeanalytical solution, which can provide highprecision / high accuracy / high throughputanalysis of 18O/16O and D/H.

    The aqueous samples are placed in10 ml screw top vials using disposablepipettes. For D/H, a platinum catalyst isadded. The vials are sealed with septa andall air is removed from the sample vials byan automated, autosampler-assistedflushing procedure which uses a mixture ofeither H2 or CO2 in He. The H2 or CO2 in theflushing He stream is used as equilibrationgas. After the required equilibration time(D: 40 min, 18O: 20 h) the whole batch ofsamples is analyzed. The use of repetitiveloop injection (1-2 min per replicate)achieves analytical precisions comparableto those from a dual inlet system.

    Alternatively, the Finnigan TC/EA, thequantitative high temperature carbonreduction Elemental Analyzer, can beintegrated with the GasBench II for highprecision analysis of D/H and 18O from asingle sub-µL injection of water.

    Dissolved Inorganic CarbonA request to replace the laborious manualpreparation of 13C of DIC for dual inletanalysis with a fast, reliable and accuratecontinuous flow method is, in fact, what ledto the development of the FinniganGasBench II. The requirement of < 0.1 ‰precision was readily exceeded, withprecisions of 0.03 – 0.05 ‰ being shown byusers. It is safe to say that the FinniganGasBench II has revolutionized DIC analysis.

    The risk of adsorption of CO2 from airinto the sea water during sample handlingrequires a different preparation of thesample vials. 3 drops of phosphoric acid (ca. 3 µL) are placed in the empty vials.After sealing the vials with septa, all vialsare automatically flushed with pure helium.The sea water samples are injected usinggastight, disposable syringes. After ashortreaction time, the CO2 in theheadspace of each vial is automatically

    analyzed using the same acquisition processas for all other Finnigan GasBench IIapplications.

    Universal O

    n-line Gas Preparation

    and Introduction System for

    Isotope Ratio MS

    Finnigan GasBench II Applications

    •Place 200 µL of thesample in the vial

    • Place all sample vials inthe autosampler tray

    • All vials are automaticallyflushed

    • Start the SequenceAcquisition

    Analysis

    He + H2HeD transfer fromH20 into H2 inthe headspace

    Screwcap

    Platinum catalyst

    200 µLAqueoussample

    • Equilibrate for 40 min

  • Dilution OFF

    He+sample

    He

    to IRMS

    Dilution ON

    δ18O and δ13C determinationof carbonatesFor more than 50 years, δ18O and δ13Cmeasurements of carbonates have been oneof the major applications of stable isotopes.The analysis of foraminifera, in particular, isone of the most demanding applications,requiring both high precision and highthroughput.

    The AutodiluterThe Finnigan GasBench II offers a uniquecomputer-controlled Autodiluter capability.If the signal height of the first sample peakexceeds a pre-defined threshold (e.g. 20 V),the diluter is activated resulting in a 3-foldreduction in signal height for thesubsequent sample peaks. The dilution isperformed in the open split, just beforetransfer into the ion source, eliminating anypossible effects on the integrity of thesample gas. The Autodiluter capabilityallows analysis of samples that would

    normally be too large to be measured. Thiscapability offers clear advantages in samplepreparation, because it reduces the need fortime-consuming weighing of samples, and itallows analysis of samples with unknownamounts of carbonates (e.g. whole rocksamples with carbonate cements).

    Finnigan GasBench IIdata acquisition,10 sample pulses,Autodiluter activatedby first sample pulse

    The Carbonate Reaction KitThe Finnigan GasBench II in carbonate modeuses the principle of individual acid bathsusing a fully automated acid dosing system.The carbonate option contains a microliterpump that allows injection of anhydrous

    phosphoric acid (103 %) into the samplevials. The double needle setup ensuresidentical reaction and analysis conditionsfor each sample. Laboratories have shownthat 80 samples per day (including 14standards for quality control) can be

    processed in routine operation. An overallprecision of 0.08 ‰ for δ18O and of 0.06 ‰for δ13C has been achieved.

    Step 1

    Sampling

    4 8 12 16

    1 5 9 13 1 5 9 13

    4 8 12 16

    Acid Dosing Sampling Acid Dosing

    Step 2

    First sample pulse out of range

    Autodiluter activated

    Referencegasespulses

  • GasBench II Options

    • Carbonate Reaction KitThe carbonate option contains a micro-liter pump that allows injection ofanhydrous phosphoric acid (103 %) intothe sample vials and a dual needle arrayfor dosing and sampling

    • 96 Sample tray (ambient temperature)• 96 Sample tray (temperature controlled)• Single cryotrap

    Trapping option with a single fused silicatrap for sub ambient gas concentration(e.g. 100 ppm CO2)

    • Dual cryotrap (PostCon)Trapping option with two traps, one1/16” nickel-wire filled stainless steel trapfor trapping ppm amounts of analyte froma fast He gas stream, and one fusedsilica trap for cryo-focusing onto theGC column head

    • Autosampler extensionsThe Finnigan GasBench II autosamplercan be extended to automate a secondperipheral device, including the TC/EA,EA, H/Device, and PreCon.

    Universal O

    n-line Gas Preparation

    and Introduction System for

    Isotope Ratio MS

    Finnigan GasBench II Combinations

    PreCon Integrationand AutomationFor gas concentrations in the low ppm andppb range, the Finnigan PreCon gives accessto the fully automated preparation and pre-concentration of trace gases such as N2O(300 ppb) and CH4 (1.7 ppm) followed bycryogenic focusing in front of the GCcolumn. The Finnigan PreCon can be loadedmanually or operated fully automaticallyusing the GC-PAL autosampler of theFinnigan GasBench II with the two lineneedle for continuous sample transfer.

    The GC-PAL can be equipped with a 96 x 12 mL sample tray. User-definedsample trays and sample containers caneasily be registered and automated due tothe fully object oriented structure of the GC-PAL. All processes are controlled by user-definable Isodat 2.0 scripts.

  • Isodat 2.0 Software

    • Easy and fast method and sequencesetup for IRMS, Finnigan GasBench IIpreparation and acquisition modes.

    • Complete control and automation of allinterface functions for sample preparationand data acquisition.

    • Automated peak and backgrounddetection with a wide selection ofdedicated detection and backgroundsubtraction algorithms.

    • Fully automated correction of the GCelution time shift of isotopomers.

    • Fully automated H3+ correction of each

    single raw data point.• Fully automated ion correction for

    isobaric ion contributions such as12C17O16O on 13C16O16O.

    • User defined ion correction formulas canbe registered in Isodat 2.0 using theIsodat 2.0 Script Language (ISL).

    • Full access to all raw data andprocessed data.

    • Full access to ion correction algorithmsand intermediate data.

    • Access to easy batch reprocessing,manual peak and background definitionincluding printouts and data export.

    • Fully customizable and multiple exports ofevaluated data to Excel, other spreadsheetprograms and databases (LIMS).

    • All printouts are fully customizable dueto object oriented print-out templatesusing the unique Isodat 2.0 ResultWorkshop package.

    • Full network compatibility with directand fast access to Windows tools.

    • Complete Isodat 2.0 system backupand retrieval within minutes usingthe Isodat 2.0 Version Handler.

    Based on the unique “Plug and Measure”concept of the new generation of IRMS(Finnigan DELTAplus XP, Finnigan DELTAplus

    Advantage and Finnigan MAT 253), theFinnigan GasBench II interface andpreparation unit is immediately recognizedand operational.

    Total configuration flexibility to adaptuser-defined hardware by device control and ISL scripts

    Isodat 2.0 is the software suite for system control, data acquisition and data evaluation.The advantage that Isodat 2.0 offers for Finnigan GasBench II applications include:

  • Universal O

    n-line Gas Preparation

    and Introduction System for

    Isotope Ratio MS

    Analytical Performance

    Mass spectrometer:Thermo Finnigan DELTA series or Finnigan MAT 253

    Finnigan GasBench II Basic Performance

    10 pulses of reference gas (amplitude 3V, H2 5V), δ notationPrecision (1σ) Linearity

    CO2 13C 0.06 ‰ 0.02 ‰/nA

    CO2 18C 0.08 ‰ 0.02 ‰/nA

    O2 18C 0.08 ‰ 0.02 ‰/nA

    N2 15N 0.06 ‰ 0.02 ‰/nA

    H2 2H 0.50 ‰ 0.20 ‰/nA

    An ion current range of 2 – 20 nA (0.6 – 6 V) is equivalent to 1.2 µg – 12 µgcarbon equivalent in the headspace of a 12 mL vial

    External precision of isotope ratios C, O, H, using the Finnigan GasBench II with 12 mL vials (n=5), δ notationWater equilibration (versus V-SMOW & SLAP)(1)

    500 µl as CO2 δ18O < 0.08 ‰200 µl as H2 δ2H < 2.0 ‰

    δ2H < 0.5 ‰ on raw data (1)

    Carbonates100 µg as CO2 δ18O < 0.1 ‰

    δ13C < 0.1 ‰

    Dissolved inorganic carbon, ocean water600 µl as CO2 δ13C < 0.08 ‰

    CO2 in air12 ml as CO2 δ13C < 0.2 ‰

    Acceptance SpecificationDuring installation, the system performanceof the Finnigan GasBench II will bedemonstrated with a mixture of CO2 in He(≥ 0.3%), to show an external precision of0.08 ‰ for δ13C and δ18O (n=5).

    A mixture of H2 in He mixture (≥ 1.0 %)is used to show an external precision (n=5)of 2.0 ‰ for δ2H.

    (1) V-SMOW & SLAP scaling: Based on IAEArecommendations all 18O and D analysis need to bebased on V-SMOW and SLAP.

    For H2/H2O equilibration with platinum catalyst. thisreferencing results in a scale expansion of up to 4 timesfrom the raw delta values to the final data, whichequivalently decreases the precision of measurements.

    On 18O determinations (CO2 /H2O) this data processingalso needs to be performed but the scaling factor usuallyis almost 1 and therefore has no effect on theperformance data.

  • Power230 V single phase, 8 A

    Gases• He, better 99.999%• CO2, better 99.995%• H2, better 99.999%• 0.3% - 1% CO2, (99.995%)

    in He (99.999%) for18O water equilibration

    • 1.0% - 2.0% H2 (99.999%)in He (99.999%) for2H water equilibration

    Optional items

    • PoraPLOT Q capillary column forseparation of N2 and CO2 (included in thestandard Finnigan GasBench II system)

    • Carbonate kit with dual needle support,acid pump and needle, phosphoric acidfor carbonate analysis

    • Temperature stabilized tray with 96 x 12 mL vials for carbonate andwater analysis

    • Hydrophobic Pt catalyst sticks for H2/H2Oequilibration

    • 5Å PLOT capillary column for goodchromatographic resolution and thus highprecision isotopic measurements of themolecular components of air (N2, O2, Ar,CH4, CO)

    • Single cryo trap for trapping of tracegases from low He flow systems

    • PostCon dual cold trap for trapping oftrace gases from high He flow systemswith subsequent cryofocusing in thesecond trap

    Literature

    • A simple, practical methodology forroutine VSMOW/SLAP normalization ofwater samples analyzed by continuousflow methods, S.T. Nelson,Rapid Commun. Mass Spectrom.14, 1044–1046 (2000)

    • Sample vial influences on the accuracyand precision of carbon and oxygenisotope ratio analysis in continuous flowmass spectrometric applications,S.T. Nelson, Rapid Commun.Mass Spectrom. 14, 293–297 (2000)

    • Continuous-flow isotope ratio massspectrometric analysis of carbonateminerals, Ch. Spötl and T.W. Vennemann,Rapid Commun. Mass Spectrom.17, 1004–1006 (2003)

    • A bacterial method for the measurementof the oxygen isotopic composition ofnitrate in marine and fresh waters, K.L.Casciotti, D.M. Sigman, M.G. Hastings,J.K. Böhlke, and A. Hilkert, AnalyticalChemistry, 74, 4905-4912 (2002)

    • Using septum-capped vials withcontinuous-flow isotope ratio massspectrometric analysis of atmosphericCO2 for Keeling plot applications, K.P. Tu,P.D. Brooks and T.E. Dawson,Rapid Commun. Mass Spectrom.15, 952-956 (2001)

    Installation Requirements

    930

    345

    870

    550

    DeltaplusFamily GasBench

    Main Module

    Sample Tray

    Autosampler

    Tem

    pera

    ture

    Cont

    rol

    (Opt

    iona

    l)

    Top view with dimensions in mm

    Documentation of systemperformance is also availablein the Finnigan GasBench IIApplication Reports.

  • BR30036_E /11/04C

    Tap our expertise throughout the life of your instrument. As an industry

    leader in analytical instruments, Thermo extends its support throughout

    our worldwide network of Thermo-trained and certified engineers who

    are experts in laboratory technologies and applications. Put our team

    of experts to work for you in a range of disciplines, from system

    installation, training and technical support, to complete asset

    management and regulatory compliance consulting. Improve your

    productivity and lower the cost of instrument ownership through our

    product support services. Maximize uptime while eliminating the

    uncontrollable cost of unplanned maintenance and repairs. When it’s

    time to enhance your systems,Thermo also offers certified parts and a

    range of accessories and consumables suited to your application.

    To learn more about our products and comprehensive service offerings,

    visit our Web site at www.thermo.com.

    Laboratory Solutions Backedby Worldwide Service and Support

    Thermo Electron (Bremen) GmbH is certified DIN EN ISO 9001:2000

    ©2004 Thermo Electron Corporation. All rights reserved.All trademarks are the property of Thermo ElectronCorporation and its subsidiaries.

    Specifications, terms and pricing are subject to change.Not all products are available in all countries. Pleaseconsult your local sales representative for details.

    In addition to these offices,ThermoElectron Corporation maintains anetwork of representativeorganizations throughout the world.

    Australia+61 2 9898 1244 • [email protected]

    Austria+43 1 333 50340 • [email protected]

    Belgium+32 2 482 30 30 • [email protected]

    Canada+1 800 532 4752 • [email protected]

    China+86 10 5850 3588 • [email protected]

    France+33 1 60 92 48 00 • [email protected]

    Germany+49 6103 4080 • [email protected]

    India+91 22 2778 1101 • [email protected]

    Italy+39 02 950 591 • [email protected]

    Japan+81 45 453 9100 • [email protected]

    Netherlands+31 76 587 98 88 • [email protected]

    Nordic+46 8 556 468 00 • [email protected]

    South Africa+27 11 570 1840 • [email protected]

    Spain+34 91 657 4930 • [email protected]

    Switzerland+41 61 48784 00 • [email protected]

    UK+44 1442 233555 • [email protected]

    USA+1 800 532 4752 • [email protected]

    www.thermo.com