fire ratedinsulated cavity closer - encon insulation · the rigid pvcu profile encloses a weather...

4
Supafix RECOMMENDED FOR CLOSING THE CAVITY AROUND WINDOW AND DOOR OPENINGS IN SECOND-FIX INSTALLATIONS WHEN A FRAME FORMER IS NOT REQUIRED. AN ECONOMICAL WAY TO ACHIEVE BUILDING REGULATIONS COMPLIANCE (31.9) Hn6 EPIC F642:X725 Uniclass L3272:P7114 CI/SfB ONE HOUR FIRE INTEGRITY FIRE RATED INSULATED CAVITY CLOSER

Upload: vocong

Post on 06-Jun-2019

220 views

Category:

Documents


0 download

TRANSCRIPT

Supa

fix

RECOMMENDED FOR CLOSING THE CAVITY AROUNDWINDOW AND DOOR OPENINGS IN SECOND-FIXINSTALLATIONS WHEN A FRAME FORMER IS NOT REQUIRED.

A N E C O N O M I C A L W A Y T O A C H I E V E B U I L D I N G R E G U L A T I O N S C O M P L I A N C E

(31.9) Hn6

EPICF642:X725

UniclassL3272:P7114

CI/SfB

ONE HOURFIRE INTEGRITY

FIRE RATED INSULATED CAVITY CLOSER

SupafixFIRE RATED INSULATED CAVITY CLOSER

Up to one hour fire integrity

Complies with new Part L Building Regulations

Economical

Available in wide range of widths for standard and check reveal cavities

Reduces risk of condensation, mould & moisture migration across the cavity

Overcomes cavity width variations

Weather resistant

Easy to install

No ties required - simply nail to blocks

Can be used on timber frame construction

SpecificationsProfileWhite non water-absorbing PVCu

InsulationWeather resistant polythene with encapsulated 140kg/m3 mineral wool

Lengths2.4 metres

Cavity widths50mm, 75mm - 80mm, 85mm - 90mm, 95mm - 100mm Other Cavity widths available on request

Minimal thermal resistance path0.45m2/KW

Specification StatementClose cavity openings at window jambs/sills and external doors utilising Dacatie Supafix - Fire Rated. Installation should be completed in accordance with the manufacturers instructions

Order codesStandard: SFR/cavity width in mmCheck Reveal: CSFR/cavity width in mm

Features

mineral wool

rigid PVCu profile

polythene encapsulation

Supafix Fire Rated (SFR) non-combustible insulated cavityclosers are the economical way to achieve building regulationscompliance and one hour fire integrity when closing cavitiesaround window and door openings. SFR provides a highlyversatile solution in second fix installation when a frame formeris not required.The rigid PVCu profile encloses a weather resistant polythene encapsulated mineralwool insulation which forms a continuous insulated cavity closer preventing coldbridging. SFR can be used with all types of door and window openings. SFR wastested at Warrington Fire Research and was found to be in accordance with BS476Cert 20 1987. SFR provides 60 minutes fire integrity and up to 60 minutes fireinsulation.

SFR is primarily designed for second fix applications and can be simply cut to lengthand push fitted into the cavity after the window or door opening has been made thuseliminating the need for cut blocks, bricks or special reveal blocks. SFR is available ina range of sizes to fit cavity widths from 50mm - 100mm, with sufficient designflexibility to tolerate rogue cavity widths, thus reducing time and cost on site.

20mm 40mm

150mm

20mm

130mm

FLUSH

CHECK REVEAL

SALES & TECHNICAL SUPPORT t: 0161 622 2020 f: 0161 622 2022 e: [email protected]

RECOMMENDED FOR CLOSING THE CAVITY AROUND WINDOW ANDDOOR OPENINGS IN SECOND-FIX INSTALLATIONS WHEN A FRAMEFORMER IS NOT REQUIRED.

APPLICATIONSFR profile is suitable for use with all window anddoor frame materials, including timber, PVCu andaluminium.

SFR is cut to the height or width of the cavity openingand then push fitted into the cavity (fig.2). Slightcavity width variations can be overcome by applyingsmall pressure. For this purpose a margin of insulatingmaterial projects from the PVCu encasement to allowa firm friction fit. In cases of extreme cavity widthvariation, this projecting insulation can be trimmed onsite with a knife to allow insertion into the cavity.

Fig. 2

THE PROBLEM OF COLD BRIDGING (Fig. 3)The problems of cold bridging are recognised in the new Part L BuildingRegulation revised 2002. Part L recommends that an insulated cavitycloser be used to overcome thermal loss that occurs in unprotected cavitiesand reveals. Thermal loss can result in problems of condensation, stainingand mould growth at the reveals of these openings. Prolonged exposure tosuch factors will lead to a deterioration of the internal plaster and paintwork. The use of SFR will help to prevent the occurance of such factors.

PART L REVISED 2002SFR will exceed the minimum requirement of 0.45 m2 K/W for thermalresistance. When for example the window is set back at 30mm, thethermal resistance will in fact exceed 0.75m2 K/W (as indicated in theRobust Detail for walls). The minimum u value requirement of 0.35W/m2

will be achieved if all products are fitted to manufacturersrecommendations and thermally efficient products are used within the construction.

Fig. 3 Identifies the heat loss from a building which isthe cause of cold bridging.

Fig. 3

SALES & TECHNICAL SUPPORT

0161 622 2020f: 0161 622 2022 e: [email protected]

QUANTUM PROFILE SYSTEMS LTD. SALMON FIELDS ROYTON OLDHAM LANCASHIRE OL2 6JG

t: 0161 622 2020 f: 0161 622 2022 e: [email protected]

DACATIE is a registered trade mark of Quantum Profile Systems Limited.

A RANGE OF PRODUCTS YOU CAN TRUST

www.dacatie.co.uk

RegulationsWarrington Fire Research tested in accordance with BS476 Part 20

Approved Document Part L revised 2002

With 30mm window frame set-back, complies with thermal requirements. BBA approved for moderate, sheltered and severe conditions. The check reveal variant can be used in very severe locations.

Manufactured to ISO9001

Dacatie D2000, TF1000/TF2000 and Supafix are BBA Approved.

SUPAFIX FR

SupafixINSULATED CAVITY CLOSER

TF1000/2000INSULATED CAVITY CLOSER

Supafix MulticloserMULTI WIDTH INSULATED CAVITY CLOSER

D2000 FIRE RATED

INSULATED CAVITY CLOSER

D2000INSULATED CAVITY CLOSER

Frame FormersINSULATED CAVITY CLOSER

Supafix FIRE RATED

INSULATED CAVITY CLOSER

D3000INSULATED CAVITY CLOSER

DPCINSULATED DPC

AccessoriesWEEPHOLES & FIXING TIES