fireball spectrum analyzer

5
Fireball Spectrum Analyzer Our Multichannel Spectroscopy system with data analysis and associated electronics covering wavelength range from 400nm to 1650nm which will be used to capture some critical data about fireball temperature , fireball duration and fireball constituents. This system will consist of 4 channels which will be used for spatial measurement at 4 different positions. The system can also capture signal in a unite way where all the 4 channels will capture signal individually at single position with even faster sampling time i.e, 100 usec. NEWAGE INSTRUMENTS & MATERIALS Head Office Address:- # 12 – 15, IInd Floor, Apna Enclave Shopping Complex, Railway Road, Gurgaon – 122001, Haryana, India | www.newagein.com Our multichannel spectroscopic system will consist of onboard data storage with a capacity of minimum 5000 spectra which is running with integration time of less the 30usec. The whole system will be consist of Silicon (CMOS) & InGaAs detectors , internal & external triggering hardware , DAQ with all the centralize software to control all the light collection optics. Our Multichannel spectroscopic system will consists of the following sub- systems: 1. Spectroscopy modules 2. Controller with Data acquisition Unit 3. Light collection optics with fiber delivery Our spectroscopy modules are based on Symmetrical Czerny –Turner which has an option of external band filters along with SMA 905 connector through which the intensity can be controlled from 0 to 100%.Also there are nd some provision to remove unwanted signal i.e, 2 harmonics which also enhances the sensitivity.

Upload: others

Post on 18-Nov-2021

38 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Fireball Spectrum Analyzer

Fireball Spectrum Analyzer

Our Multichannel Spectroscopy system with data analysis and associatedelectronics covering wavelength range from 400nm to 1650nm which willbe used to capture some critical data about fireball temperature , fireballduration and fireball constituents. This system will consist of 4 channelswhich will be used for spatial measurement at 4 different positions.The system can also capture signal in a unite way where all the 4 channelswill capture signal individually at single position with even faster samplingtime i.e, 100 usec.

NEWAGEINSTRUMENTS & MATERIALS

Head Office Address:- # 12 – 15, IInd Floor, Apna Enclave Shopping Complex,

Railway Road, Gurgaon – 122001, Haryana, India | www.newagein.com

Our multichannel spectroscopic system will consist of onboard datastorage with a capacity of minimum 5000 spectra which is runningwith integration time of less the 30usec. The whole system will beconsist of Silicon (CMOS) & InGaAs detectors , internal & externaltriggering hardware , DAQ with all the centralize software to controlall the light collection optics.

Our Multichannel spectroscopic system will consists of the following sub-systems:1. Spectroscopy modules2. Controller with Data acquisition Unit3. Light collection optics with fiber delivery

Our spectroscopy modules are based on Symmetrical Czerny –Turnerwhich has an option of external band filters along with SMA 905 connectorthrough which the intensity can be controlled from 0 to 100%.Also there are

ndsome provision to remove unwanted signal i.e, 2 harmonics which alsoenhances the sensitivity.

Page 2: Fireball Spectrum Analyzer

Spectroscopy Modules:

Our spectroscopy module will consist of 4 synchronized channels whereeach channel will consist of VIS NIR and NIR spectrometer.

VIS NIR: 400 to 1000 nm, other option as per user requirement.NIR: 1000 to 1650 nm, other option as user requirement

Both VIS NIR and NIR spectrometer have solution to work together in Synchronize mode with each other as well as independently.

NEWAGEINSTRUMENTS & MATERIALS

Head Office Address:- # 12 – 15, IInd Floor, Apna Enclave Shopping Complex,

Railway Road, Gurgaon – 122001, Haryana, India | www.newagein.com

S. No. Specifications Value Value

a. Type VIR NIR NIR

b. Detector CMOS, 2048 pixels InGaAs, 256 pixels

c. Wavelength range 400 to 1000 nm 1000 to 1650 nm

d. SNR 300:1 1900:1

e. Senstivity 3,60,000 counts/uW per ms integration

13,00,000 counts/uW per ms integration

f. Spectral resolution (with 25 um slit )

1.5 nm 6 nm

Page 3: Fireball Spectrum Analyzer

NEWAGEINSTRUMENTS & MATERIALS

Head Office Address:- # 12 – 15, IInd Floor, Apna Enclave Shopping Complex,

Railway Road, Gurgaon – 122001, Haryana, India | www.newagein.com

g. Slits Manually replaceable with slit kit (10, 25, 50, 100 um

h. Integration time 30 usec to 2 sec

I. Data transfer speed 0.6 ms/scan

j. A/D converter 16 bit, 6 MHz

k. Calibration Calibration for irradiance & non linearity correction

l. Optical fober input port SMA 905

m.) Trigger mechanism Internal and external

n. Communication USB 3.0 or faster

o. Memory Inbuilt memory for on board storage of spectra with minimum 50000 spectra.

p. Fiber 2.1 bifurcated optical fiber with SMA 905 connector

Controller with data acquisi�on unit :

This unit is to control and synchronize both spectroscopy modules and has inbuilt processor with i5 Processor, 8 inch touch screen, internal RAM of 8GB, Video out port to connect an external 40 inchdisplay. This unit will have centralized control software. This unit isalso consisting of electronic boards, processor, on board storage, display, fiber coupling option as well as junction cable box.

Page 4: Fireball Spectrum Analyzer

NEWAGEINSTRUMENTS & MATERIALS

Head Office Address:- # 12 – 15, IInd Floor, Apna Enclave Shopping Complex,

Railway Road, Gurgaon – 122001, Haryana, India | www.newagein.com

S. No. Specifications Value

a. Controller display The controller will have inbuilt processor and onboard touch displayof at least 8 . other other options are also available.

b. Trigger box with synchronization

Each module will have its independent trigger unit also for independent operation of channels. Unit is also be able to synchronize all channels and have provision to generate fixed delays within the channel. Trigger resolution is less than 10 usec. The unit also has provision to generate trigger automatically by optical trigger as well as manually through software.

c. External triggering and gated delay options

External fast photodiode (rise time<20nsec) is inbuilt int the system.Provision of external TTL triggering to trigger the entire unit. Gated delay module to control capturing time of spectrometer channels with resolutions os 5 usec to few sec.

d. DAQ System Portable rugged external controller DAQ system with i5 processor or latest, sun readable touch screen 15 inches. OS windows XP, data storage capacity of 250 GB and internal memory

e. Operational software

The module will run using intuitive instrument control and data acquisition software to control, monitor and to do all spectroscopic analysis like statistical analysis, logging, data analysis, irradiance measurement, color temperature and emission spectra in real time as well as offline analysis.

f Software programmable feature

Windows based controlling and analysis software in LAB VIEW platform with following feature. • Run all channel synch or individually• Spectra of all four channels will be visible as a combine merged graph as well as individually in tiled fashion in single window.

• Trigger, programmable delay and gate control will be provided

• Save all spectra at a time.

• Features like color temperature, Irradiance, absorption and emission spectra.

• Logging facility of data in real time.

• Integration time of each spectrometer channel will be programmable

• Statistical Analysis tool for logged data will be there.

Page 5: Fireball Spectrum Analyzer

NEWAGEINSTRUMENTS & MATERIALS

Head Office Address:- # 12 – 15, IInd Floor, Apna Enclave Shopping Complex,

Railway Road, Gurgaon – 122001, Haryana, India | www.newagein.com

g. Connections Fiber connection port, connection for Dc power supply and for external DC power source. USB signal output port, LAN Port, External display port, Triggering and synch connector to connect with external spectroscopy module.

h. Rugged Mechanical hosing Complete system is packed in field portable rugged mechanical housing; Spectroscopic modules is packed in compact fashion.

Light Collec�on Op�cs with Fiber Delivery :

The light collection optics with the fiber delivery consists ofopto-mechanical assorted assemblies and recalibration setup for lightand coupling by fiber optics.

a. Multifurcated optical fiber As Per user's requirement.

b. Collimator Fused silica SMA connectorized collimators of 8 mm and 50 mm focal length. Other Options available as Per users requirement.

c. Calibration Kit I) 10 W Tungestun Halogen Lamp, irradiance calibration, fan cooled with power supply ii) Spectral calibration lamp (Hg-Ar) with power supply and mounting adapter Other option as per users requirement.

d. Filters Interference filters (550nm, 780nm, 990nm) & Low pass filter (550nm and 1350nm) Other option as per users requirement.

e. Spectral peak identification software:

Spectral peak identification software is used for elemental and chemical composition analysis. The software is having following feature: 2D and 3D data visualization, data optimization, mathematical evaluation, spectrum arithmetic, averaging multiple spectra, elemental analysis libraries, peak picking etc.