firetrace presentations
DESCRIPTION
Main Office:No. 26-1, Jalan Damai Perdana 1/8B, Bandar Damai Perdana Cheras, 56000 Kuala Lumpur.Phone : +603 – 9100 5718 Facsimile : +603 – 9100 4586E-Mail : [email protected]://www.firespec.netTRANSCRIPT
DCS CABINET
Main Office:
FIRESPEC ENGINEERING (M) SDN BHD
No. 26-1, Jalan Damai Perdana 1/8B, Bandar Damai Perdana Cheras, 56000 Kuala Lumpur.
Phone : +603 – 9100 5718 Facsimile : +603 – 9100 4586
E-Mail : [email protected]
http://www.firespec.net
Automatic Fire Detection and Suppression
What do we do?
We stop this from happening
“We have never had a fire!”
Causes of Fire
• Short Circuit• High Speed/Friction• Broken Tool• Operator Error
What is Firetrace?
Self-contained automatic fire detection and suppression system
Pneumatic linear heat/flame detector
Detection and suppression at the ignition point!
Put the fire out where and when it starts, not after your expensive machinery or building is destroyed!
How the Tubing Works
Tubing bursts at the point closet to Flame or Heat
when it reaches 212 Degrees Fahrenheit creating a Discharge Nozzle!
Electrically non-conductive Firetrace Detection Tubing is a linear pneumatic fire/heat
detector
Firetrace Detection
Tubing
Requires No Power
Easy Installation
Cost Effective
Tolerates the
vibration, dirt,
and
temperature
extremes of
many different
environments
Heat sensitive
polymer tubing
reacts to heat
and radiant
energy of a fire
by bursting,
thus releasing
the fire
suppressant
agent
Flexible tubing!
New systems
or retrofits are
easy to install and
maintain
Rapid detection
and rapid
suppression to
quickly reduce
damage and
risks
Firetrace Advantages
DCS CabinetElectrical SwitchFlexible Tubing – allows us
to provide detection and suppression almost anywhere
Detection and Suppression at the critical point – DCS Cabinet
Tube Burst Point -the suppression agent was delivered straight onto the heart of the fire
Actual Suppressions
Clean Agent SystemIndirect Low Pressure
Low Pressure Medium
Cross Pattern Nozzles
Detection Tubing Manual Release
Indirect Low Pressure
Clean Agent System
Clean Agent SystemIndirect Low Pressure
Low Pressure Medium
Cross Pattern Nozzles
Detection Tubing
Manual Release
Indirect Low Pressure
Clean Agent System
FiretraceInstallations
Other Machine Applications
• Mist Collectors
• EDM Machines
• Dust Collectors
• Screw Machines
• Grinding Machines
The Risks
With Firetrace Without Firetrace
Cost of Protection
Lost Production
Lost Income
New Machine or expensive repair
Higher Insurance Rates
Risk Analysis System
Design
Installation
Identify critical
equipment and
processesType of Fire (Class)
Type of Agent
Type of System
(Direct or Indirect)
Volume of Area
Easy Installation and
Maintenance
Installs in, on or near
the machine
Pre-Engineered Systems
Firetrace Systems
Direct Low Pressure System
The Firetrace Tubing is both a
flame/heat detector and
discharge nozzle rupturing at
212 degrees Fahrenheit!
Indirect Low Pressure System
Tubing ruptures creating
pressure drop which releases
suppressant faster through
separate piping network!
Suppression Agents
Clean Agent
FM-200, FE-13, FE-25, FE 36, Novec 1230
Dry Chemical
ABC, BC, D (metals), D (lithium)
Other
CO2 and Foam
Fire Alarm Panels
Building Management Systems
Equipment Shut Down, shunt trip, fan/damper control and more…
Manual Release
Pressure SwitchInterfaces with…
System Accessories
Manual Release (Double Action)
Pressure Switch (Cylinder and EOL)
Solenoid Valve
Smoke Detector
Audible Alarm
Time Delays
And more…