first short report

8
Cryogenic Carbon Capture Brief summary report Nov. 2015 Sahand Faraji Berk Celiktas

Upload: sahand-faraji

Post on 19-Feb-2016

225 views

Category:

Documents


8 download

DESCRIPTION

CCC lab scale report.

TRANSCRIPT

Page 1: First Short Report

Cryogenic Carbon Capture

Brief summary reportNov. 2015

Sahand FarajiBerk Celiktas

Page 2: First Short Report

GC Calibration78 Experiment Have been carried out

Standard Gas Cylinder( around 40 exp)

• Real Gas Percentage(±2%):CO2: 74.48%; O2: 17.65%; N2: 7.88%

• Experiment results:CO2: 80; O2: 14; N2: 6

Questions and suggestion:• According to approximation:

O2, N2 are acceptable But CO2 is not!

• Accept this Calibration (which work for us)

• Buying new standard cylinder• Changing method which is not recommended

Page 3: First Short Report

GC Calibration78 Experiment Have been carried out

Entrance Mix gas( around 40 exp.)

• The exact gases amount in mixture are obtained, BUT:

Questions and suggestion:• The time of sweeping is changed

variously from 3min to 40min (Based on the mixture and the flowrate)

• →Vacuum pump could solve the major part of this problem.Detector’s solid substance need to be sweeping. So the time consumption is inescapable.

Page 4: First Short Report

Cryogenic Carbon Capture2 Experiment Have been carried out

The experiment took about 1hour.This time consume for:• Chiller cooling• Compressor

pressurizing

Pros:• No leakage have been

recorded in the system.• No water have been

observed after the third condenser.

• Process controller system correctly worked

• Steam generator worked well in the system

Cons and bottlenecks:• Liquid CO2 have been

obtained BUT the separation faced a problem.

• The compressor oil vomiting have been happened in both case.

Page 5: First Short Report

Cons and bottlenecks:

Presence of CO2 is completely visible in the purge line:

(The intense temperature drop is an evidence as well as GC

recordings)

Page 6: First Short Report

Cons and bottlenecks (Bottleneck):The milestone picture

Page 7: First Short Report

Cons and bottlenecks (Bottleneck):

The Milestone Picture:• The left gauge presented the outlet flow pressure, this is not demanded!!• The outlet pressure must be equal to the liquefaction conditions(P>80bar)• After a while from the beginning of the experiment this pressure is applied to the first drum and that is the reason of

compressor oil vomiting!• What is the difference between CO2 cylinder and ours?

Page 8: First Short Report

Extra Suggestion:

Starting to learn Aspen Hysys for modelling the system required.