flat and ribbon cables - hi-tech controls...din vde 0295, bs 6360 cl. 5 and iec 60228, fine or extra...

10
(800) 677·8942 I (303) 680·5159 Click or Call for a Quotel Flat and Ribbon Cables C HELUKABEL www. h itech controls .com Photo· HELUKABEL "

Upload: others

Post on 04-Feb-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • (800) 677·8942 I (303) 680·5159 Click or Call for a Quotel

    Flat and Ribbon Cables

    C HELUKABEL

    www. h itech controls .com

    Photo· HELUKABEL"

    http://www.hitechcontrols.com/cable_index.htm?ex=e3iejl-4aq1oy-x1qqv3-ym8518http://www.hitechcontrols.com/contactwin.html?ex=e3iejl-4aq1oy-x1qqv3-pkjrqr

  • ~HI-TECH ~ CONTROLS, INC.

    (800) 677·8942 I (303) 680·5159 Click or Call for a Quotel

    www. h itech controls .com

    Flat and Ribbon Cables

    Flat cables in PVC and neoprene design are used as trailing cables for cranes, open field conveyors and shelve service devices.

    Flat cables offer the following advantages:

    • Extremely small bending radius • High flexibility • Minimum wastage of space • Packeting possibilities

    An expert and proper installation is important to ensure perfect functioning . Please follow the corresponding fitting instructions.

    Flat cables according to UL-standard are available on request.

    Ribbon cables are ideal for use because of the excellent flexibility as connecting cable in electronics and in control engineering.

    C HELUKABEL

    http://www.hitechcontrols.com/cable_index.htm?ex=e3iejl-4aq1oy-x1qqv3-ym8518http://www.hitechcontrols.com/contactwin.html?ex=e3iejl-4aq1oy-x1qqv3-pkjrqr

  • ~HI-TECH ~ CONTROLS, INC.

    (800) 677·8942 I (303) 680·5159 Click or Call for a Quotel

    www. h itech controls .com

    contents

    Description -------------------------------------------------------------------------------

    PVC-flat CHOS VVH6-F/H07 VVH6-F), 300/SOOV and 45017SOV ... ... ........ ..... ........ ........ ..... ... .. ... ........ .. ... ........ ........ .. ........... ........ ........ .. ... ... .

    NEO-Fiat. IN>GFLGOu .... ... ...... ... .. .... .... .. .. .. .. .. ... ... ... .. .. .. .. .. .. .. .. .... ... ..... ... .. ... ........ ..... ... .. ... ........ .. ... ... .. ... ....... ... ..... ........ ... ..... ..... ... ..... ...... .

    PVC-flat-CY, screened . EMC-preferred type .. ... .. .. ..... ........ ..... ... ..... ... .. ... ........ ..... ..... ... ..... ... ............. ..... ... ..... ........ ........ .. ... ... ....... ........ .. ... . .

    NEO-Fiat-C, !MCHOU> screened, EMC-preferred type .... ........ ..... ........ .... .. .. ........ .. ... ........ ..... ... .. ........... ........ ..... ........ ........ .. ... ... ..... ........ ... .... . .

    Ribbon Cables. Tvpe L. Type L AWG 28. Type o ... .. .. ... ... .. ... .... .. .. .. .. .. ... .... ............. ........ ..... ... .. ........... .. ... ........ ... .. ... ............. ........ ... ....... ..... . . TUBEFLEX-Y, roundshaped flat ribbon cable for IDC-technlque. pitch 1,27 mm ........ .... .... .. ...... .. .. .. .. .. ........... .. .... ................................................ .

    TUBEFLEX-

  • ~ HI-TECH (800) 677 8942 1 (303) 680 5159 www.hitechcontrols.com ~ CONTROLS, INC. Click ; r can tor a Quo;el

    PVC-flat (H05 VVH6·F/H07 VVH6·F) 3oolsoovand4so/7sov

    [Ro~

    Technical data • Special PVC-flat cable,

    H05 VVH6-F to EN 50214 H07 VVH6-F to HD 359 52 (25 mm2 and above in adapted>

    • Temperature range flexing -5 oc to +70 oc fixed installation -40 •c to +80 •c

    • Nominal voltage H05 VVH6-F =up to 1 mm2 Uo/U 300/500V H07 VVH6-F = 1,5 mm2 Uo/U 450/750 V

    • Test voltage H05 VVH6-F = up to 1 mm2 2000 V H07 VVH6-F = 1,5 mm2 2500 V

    • Minimum bending radius 10x cable thickness

    • Radiation resistance up to 80x106 cJ/kg

  • ~HI-TECH ~ CONTROLS, INC.

    NEO·Fiat (N)CiFLcou

    [RoH-s!

    Technical data • Special Neoprene-flat cable adapted

    to DIN VDE 0250 part 809 • Temperature range

    flexing -25 oc to +60 oc fixed installation -40 oc to +80 oc

    • Nominal voltage UO/U 300/500 v • Test voltage 3000 v • Minimum bending radius

    10x cable thickness • Radiation resistance

    up to 50x106 cJ/kg (up to 50 Mradl

    Application

    (800) 677·8942 I (303) 680·5159 Click or Call for a Quotel

    cable structure • Bare or tinned copper. stranded to

    DIN VDE 0295, BS 6360 cl. 5 and IEC 60228, fine or extra f ine wire stranded according to different cross-sections 1 to 25 mm2 - class 6. col. 4 35 to 95 mm2 - class 5

    • Special rubber core insulation Gl1, to DIN VDE 0207 part 20

    • Core identification up to 5 cores. colour code to DIN VDE 0293 7 cores and above with number printing

    • Cores laying parallel • Art.No. 28007 and 28013 cable structure

    6x4 • Green-yellow earth core • Special rubber outer sheath 5GM2, to

    DIN VDE 0207 part 21 • Colour black

    www. h itech controls .com

    Properties • Special rubber outer sheath. cold-resistant • Extensively oil resistant. oil-/ chemical

    Resistance - see table Technical Informations

    • Extremely small bending radius • High f lexibility • Minimum waste of space • Packeting possibility • Behaviour in f ire:

    Test according to VDE 0482-332 -1-2, DIN EN 60332-1-2/ IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method Bl

    Note • G =with green-yellow earth core:

    x =without green-yellow earth core (0Zl. • AWG sizes are approximate equivalent

    values. The actual cross-section is in mm2 .

    Neoprene type of f lat cables are used mainly as trailing cable for crane installations, floor conveyer systems and shelf control units. These cables are also available for export with UL-approval on request. Installation notes Cables reels with flat cables must be transported in standing position on the flange. A bending flexibility can be achieved on a plane surface. For this purpose. the corresponding fitting instructions should be followed. • Put the cable trolly on the guiding rail or upon carrier beam and push them together at the starting point. The distance between the

    bedding surface of two cable trollys must be wider than the double thickness of a cable-packet. • During the packeting performance. it must be started with the smaller cross-section which lays on the bedding surface and will be builded

    successively so that the biggest cross-section is laying on the top • Further. be careful of a symmetrical load distribution. • In case of multicore f lat cables with small cross-section, smaller than 2,5 mm2, is very critical due to its low tensile stress. In such case, you

    should add 10% reserve wire for calculation. C E= The product is conformed with t he EC Low-Voltage Directive 2006/95/EG.

    Part no. No.cores x outer cop. weight AWC·No. Part no. No.cores x Outer cop. weight AWC·NO. cross-sec. dimension weight approx. cross-sec. dimension weight approx. mm• approx. mm kgtkm kgtkm approx. mm kgtkm kgtkm

    28001 4 G 1.5 5.9 X 16.2 58.0 234.0 16 11.6 X 35,6 614.0 1430.0 6 28002 5 G 1,5 5,9 X 23.7 72.0 304.0 16 12,2 X 48.2 768,0 1590,0 6 28003 7 G 1,5 5,9 X 30.5 101,0 391,0 16 14,1 X 45,8 960.0 1890,0 4 28004 8G 1,5 5,9 X 34,0 115,0 441.0 16 14,7 X S8,3 1200.0 2215.0 4 28005 10G 1,5 5,9 X 43.5 144.0 460.0 16 1S,3 X 78,7 1680.0 3000.0 4 28006 12 G 1,5 6,5 X 50.4 173,0 646.0 16 15.8 X 50,8 1344,0 2460.0 2 28007 24 G 1,5 (6X 4) 13.0 X 56.0 346,0 1290,0 16 16,4 X 64,4 1680,0 2880,0 2 28008 4G2.5 7.2 X 19.6 96.0 316.0 14 16,4 X 86,4 2352,0 4100,0 2 28009 5G2.5 7.2x27.8 120,0 391.0 14 18,6 X 60.2 1920.0 3385.0 1 28010 7G2,5 7,2 X 36.1 168,0 533,0 14 21,0 X 68,0 2688.0 4480,0 210 28011 8G2.5 7,2 X 40.2 192.0 602.0 14 24,1 X 78,6 3648,0 5990.0 310 28012 12 G 2.5 7,8 X S9,4 288,0 890,0 14 25.5 X 84,2 4608.0 7240.0 4 /0 28013 24 G 2.5 (6 X4) 15,5 X 66,8 S76,0 1480,0 14 28014 4C4 8,8 X 24,2 154.0 506.0 12 28015 5C4 8.8 X 33,4 192,0 621.0 12 28016 7G4 8,8 X 42,5 269,0 851,0 12 28017 4G6 9.6 X 27.4 230.0 661,0 10 28018 5G6 9,6 X 37.4 288.0 740.0 10 28019 7 G6 9.6 X 47,2 403.0 1004.0 10 28020 4C10 10,4 X 30,8 384,0 1027.0 8 28021 5 c 10 10.4 X 41 ,6 480.0 1171,0 8

    Dimensions and specifications may be changed without prior notice. (RJ01)

    C HELUKABEL

    http://www.hitechcontrols.com/cable_index.htm?ex=e3iejl-4aq1oy-x1qqv3-ym8518http://www.hitechcontrols.com/contactwin.html?ex=e3iejl-4aq1oy-x1qqv3-pkjrqr

  • ~HI-TECH ~ CONTROLS, INC.

    (800) 677·8942 I (303) 680·5159 Click or Call for a Quotel

    PVC·flat•CY screened, EMC-preferred type

    ~~ -:!7~

    www. h itech controls .com

    ~ _ ~~ HELUKABEL PVC-flach-CY Sx4x0,5 QMM / 27101 300/500 V 001042630 C E

    I R~

    Technical data • Special PVC-flat cable. screened. adapted

    to DIN VDE 0283 part 2 • Temperature range

    f lexing -5 •c to +70 •c f ixed installation -40 •c to +80 •c

    • Nominal voltage Uo/U 300/500 v • Test voltage 3000 v • Breakdown voltage

    min. 6000 V • Minimum bending radius

    15x cable thickness • Radiation resistance

    up to 80x106 cJ/kg

    Application

    Cable structure • Bare copper. fine wire conductors

    according to DIN VDE 0295 and IEC 60228 cl. 5, BS 6360 cl. 5

    • Special PVC insulation • core identification see below • Cores screened individually or in bunches • Cores laying parallel • Copper screened braiding, approx. 85%

    coverage • Special PVC outer jacket black

  • ~HI-TECH ~ CONTROLS, INC.

    (800) 677·8942 I (303) 680·5159 Click or Call for a Quotel

    NEO·Fiat-C screened, EMC·preferred type

    - -

    www. h itech controls .com

    HELUKABEL NEO-flach-C 8x0,5 OMM I 28100 300/ 500 V 001042631 C (

    .. "' ... -~ ........

    • -RoHS] Technical data • Special-Neoprene-flat cable, screened,

    adapted to DIN VDE 0250 part 809 • Temperature range

    flexing -25 octo +60 oc fixed installation -40 oc to +80 oc

    • Nominal voltage Uo/ U 300/500 v • Test voltage 3000 v • Minimum bending radius

    approx. 15x cable thickness • Radiation resistance

    up to 50x106 cJ/kg

  • ~HI-TECH ~ CONTROLS, INC.

    (800) 677·8942 I (303) 680·5159 Click or Call for a Quotel

    www. h itech controls .com

    Ribbon Cables Type L, Type L AWG 28, TypeD ·-------------------------------- --- -------- -- -·------------------------------------------ ------------------ --- -- -

    Typ L AWG 28 ------------------------------------ --------------------------------- ------- ---------------------------------- - ------------------------------------------- ------------------------------------ -- -- - ------------------------------------ ---------- ------------------------------------- ---- -- --------------- --------------- ---------- - -------------- -

    Typ D Typ L

    - - ------------------- = - _- ---------------

    lRoHSI

    Technical data Type L

  • ~HI-TECH ~ CONTROLS, INC.

    TUBEFLEX·Y

    Technical data

    (800) 677·8942 I (303) 680·5159 Click or Call for a Quotel

    www. h itech controls .com

    roundshaped flat ribbon cable for IDe-technique, pitch 1,27 mm

    Cable structure Properties • Roundshaped special Flat Ribbon Cable • Stranded tinned copper conductor.

    size AWG 28 • PVC self-extinguishing and flame retardant

    according to VDE 0482-332-1 -2, DIN EN 60332-1-2/IEC 60332-1

  • ~HI-TECH ~ CONTROLS, INC.

    (800) 677-8942 I (303) 680-5159 Click or Call for a Quotel

    www. h itech controls .com

    TUBEFLEX·(St>·CY roundshaped flat ribbon cable, screened, for IDe-technique, pitch 1,27mm, EMC-preferred type

    IRoHS]

    Technical data • Roundshaped special Flat Ribbon Cable,

    screened • conductor resistance at 20 oc

    max. 230 Ohm/km • Temperature range

    -20 oc up to +80 oc • Voltage rating max. 300 v • Test voltage

    core/core 2000 v core/screen 2000 V

    • Dielectric strength, Spark-test 3000 v

    • Insulation resistance min. 20 MOhm x km

    • Capacitance ca. 75 pF/m

    • Impedance 115 Ohm • Minimum bending radius

    15x cable 0 • Radiation resistance

    up to 80x106 cJ/kg