flexcoat w500mphk123.weebly.com/uploads/3/1/3/7/31378773/w500-147.04.pdf · t-017-05 t-025-06 utm:...

7
www.labondhk.com Member Of Master Proofer Corporation LTD www.labondhk.com LABOND Range of products are designed, manufactured and supplied by MASTER PROOFER COMPANY LTD Head Office: 139A Hung UK Tsuen, Ping Shan, Yuen Long, N.T., Hong Kong Tel :(852)2609 2300 Fax:(852) 2609 2309 E-mail:[email protected] Every endeavor has been made to ensure that the information given herein is true and reliable, but it is given only for the guidance of our customers. The Company cannot accept any responsibility for loss or damage or infringement of patent right that may result from the use of the information, due to the possibility of variations of processing or working conditions and of workmanship outside our control.. Users are advised to Confirm the suitability of the products with their own tests. Any dimensions shown are approximate. Form-S1.1 960401 Form-MKT/LABF/341.01 Control Reference: TCH/W500/295.06 Version:06 page 1 / 4 FLEXCOAT W500 Single Component Liquid Applied Acrylic Waterproofing Membrane 單組份液態應用式丙稀酸防水塗膜 1 . 0 Description FLEXCOAT W500 is a high performance elastomeric, single component, moisture curing acrylic copolymer meeting low VOC requirement as specified by law of HKSAR regards the Air Pollution Control (Volatile Organic Compounds) Regulation ; FLEXCOAT W500 is supplied in the form of a ready-to-use paste for the waterproofing of both horizontal and vertical surfaces. Once dry, it becomes a flexible film with excellent UV resistance and weatherability. Because of it’s excellent UV resistance property, FLEXCOAT W500 is an ideal material for totally exposed roofing and External Wall facade system, i.e. FLEXCOAT W500 serves as finishing coat and not to be covered by onward C/S screed or Tiles etc. It is not recommended to apply FLEXCOAT W500 as inverted roofing system or covered by other materials. While Flexcoat Sandwich System W500 is a Fire retarding membrane meeting with BS476,pt7, it also an ideal sound and thermal insulation layer to building structure or flashing system. It is paintable by Acrylic painting system to provide excellent decorative effect. 2.0 Technical Data * Based on Test Report No.: 040123ST40695 from MateriaLab, a Recognized Laboratory under HOKLAS Accreditation Scheme. Adhesion Strength (without PRIMER) Water Absorption % Tensile Strength Elongation at Break (%) Q-U-V Accelerated Weathering Test Hardness Scale (Shore A) Fire Resistance VOC Content Other In House Testing Crack Bridging Water Vapour Transmission Crack Time Application Temperature Fire Resistance Smoke evolved Flash Point Value 0.75 - 1 N/mm 2 2.31 % 2.34 N/mm 2 152% PASSED 63 Class 1 11g/L > 2mm 34.288/m 2 /24hrs 12 hrs 5°- 40°C zero 4 Water Based Test Method ASTMD454:95 ASTMD570-81 ASTMD412-92 ASTMD412-92 ASTMG53-88 ASTMD2240-00 BS476 pt7 USEPA Method 24 & SCAQMD Method 303-91 ASTMC836-89 ASTME96-94 - - AS1530 part 3 AS1530 part 3 - Equipment Pull-off Tester T-017-05 T-025-06 UTM: T-019-2 UTM: T-019-2 - Hardness Tester T-102-1 - - - - - - - - 3.0 Typical Application Flexcoat W500 is a single component product curing by absorbing air moisture to form flexible film. After completing it’s curing process, it becomes an high performance coating for waterproofing new or old roofs, corrugated roof, Terraces, precasting joints, chimney stacks gutter, facade, cracks expansion joint, etc. Flexcoat W500 can be applied onto most types of substrate: asphalt, concrete, roofing felt, asbestos, iron sheeting, slate, clay tiles, gutters etc.

Upload: others

Post on 07-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FLEXCOAT W500mphk123.weebly.com/uploads/3/1/3/7/31378773/w500-147.04.pdf · T-017-05 T-025-06 UTM: T-019-2 UTM: T-019-2 - Hardness Tester T-102-1 - - - - - - - - 3.0 Typical Application

www.labondhk.com Member Of Master Proofer Corporation LTD www.labondhk.com

LABOND Range of products are designed, manufactured and supplied by MASTER PROOFER COMPANY LTD

Head Office: 139A Hung UK Tsuen, Ping Shan, Yuen Long, N.T., Hong Kong

Tel :(852)2609 2300 Fax:(852) 2609 2309 E-mail:[email protected]

Every endeavor has been made to ensure that the information given herein is true and reliable, but it is given only for the guidance of our customers. The Company cannot accept any responsibility for loss or damage or

infringement of patent right that may result from the use of the information, due to the possibility of variations of processing or working conditions and of workmanship outside our control.. Users are advised to

Confirm the suitability of the products with their own tests. Any dimensions shown are approximate. Form-S1.1 960401

Form-MKT/LABF/341.01

Control Reference: TCH/W500/295.06 Version:06 page 1 / 4

FLEXCOAT W500

Single Component Liquid Applied Acrylic Waterproofing Membrane

單 組 份 液 態 應 用 式 丙 稀 酸 防 水 塗 膜

1 . 0 Description

FLEXCOAT W500 is a high performance elastomeric, single component, moisture curing acrylic copolymer meeting

low VOC requirement as specified by law of HKSAR regards ‘the Air Pollution Control (Volatile Organic

Compounds) Regulation ; FLEXCOAT W500 is supplied in the form of a ready-to-use paste for the waterproofing of

both horizontal and vertical surfaces. Once dry, it becomes a flexible film with excellent UV resistance and

weatherability. Because of it’s excellent UV resistance property, FLEXCOAT W500 is an ideal material for totally

exposed roofing and External Wall facade system, i.e. FLEXCOAT W500 serves as finishing coat and not to be

covered by onward C/S screed or Tiles etc. It is not recommended to apply FLEXCOAT W500 as inverted roofing

system or covered by other materials. While Flexcoat Sandwich System W500 is a Fire retarding membrane meeting

with BS476,pt7, it also an ideal sound and thermal insulation layer to building structure or flashing system. It is

paintable by Acrylic painting system to provide excellent decorative effect.

2.0 Technical Data * Based on Test Report No.: 040123ST40695 from MateriaLab, a Recognized Laboratory under HOKLAS

Accreditation Scheme.

Adhesion Strength (without PRIMER)

Water Absorption %

Tensile Strength

Elongation at Break (%)

Q-U-V Accelerated Weathering Test

Hardness Scale (Shore A)

Fire Resistance

VOC Content

Other In House Testing

Crack Bridging

Water Vapour Transmission

Crack Time

Application Temperature

Fire Resistance

Smoke evolved

Flash Point

Value

0.75 - 1 N/mm2

2.31 %

2.34 N/mm2

152%

PASSED

63

Class 1

11g/L

> 2mm

34.288/m2/24hrs

12 hrs

5°- 40°C

zero

4

Water Based

Test Method

ASTMD454:95

ASTMD570-81

ASTMD412-92

ASTMD412-92

ASTMG53-88

ASTMD2240-00

BS476 pt7

USEPA Method 24 &

SCAQMD Method

303-91

ASTMC836-89

ASTME96-94

-

-

AS1530 part 3

AS1530 part 3

-

Equipment

Pull-off Tester

T-017-05

T-025-06

UTM: T-019-2

UTM: T-019-2

-

Hardness Tester

T-102-1

-

-

-

-

-

-

-

-

3.0 Typical Application Flexcoat W500 is a single component product curing by absorbing air moisture to form flexible film. After completing

it’s curing process, it becomes an high performance coating for waterproofing new or old roofs, corrugated roof,

Terraces, precasting joints, chimney stacks gutter, facade, cracks expansion joint, etc. Flexcoat W500 can be applied

onto most types of substrate: asphalt, concrete, roofing felt, asbestos, iron sheeting, slate, clay tiles, gutters etc.

Page 2: FLEXCOAT W500mphk123.weebly.com/uploads/3/1/3/7/31378773/w500-147.04.pdf · T-017-05 T-025-06 UTM: T-019-2 UTM: T-019-2 - Hardness Tester T-102-1 - - - - - - - - 3.0 Typical Application

FLEXCOAT W500

Acrylic Waterproofing Coating

www.labondhk.com Member Of Master Proofer Corporation LTD www.labondhk.com Control Reference: TCH/W500/295.06 Version:06 page 2 / 4

4.0 Application Details 4.1 Horizontal Surface (Flat roof, Tiled pitch roof, corrugated sheet roof, terrace roof, gutter, expansion join, etc)

4.11 Surface Preparation:

A) All surface should be sound, clean, dry, free of dust, oil, grease or other contamination. Loose matter should be

removed by abrasion, compressed air or high pressure water.

B) Concrete Surface should be either light steel towel finished or being made flat by a layer of cement/sand screed

Sufficient time for curing of C/S should be given before laying FLEXCOAT W500)

C) All shrinkage and inactive/ non- structural cracks under 1.6mm (1/16-inch) should be pretreated with one coat of

Flexcoat W500.

D) All right angle joints between parapet wall and slabs should be treated with cementitious fillet.

E) For chalky substrate or those area where required improvement for better adhesion with FLEXCOAT W500, one

coat of SEALCOAT W501 could be applied as primer coat and allow at least 45 min for cure before application of

“Flexcoat W500” System.

4.12 Laying of Waterproofing System:

A) 2 coats of “FLEXCOAT W500” + one layer of “MPMESH A900” in between coat with film thickness of not less than

1mm.

B) It can be applied by roller, brush or towel.

4.2 Vertical surface (façade, external wall, parapet etc.)

4.21 Surface preparation:

Following the step A, B, C, as specified in above issue no. 4.11

C) Any active cracks must be bridged with 25mm wide “reinforcing strip” comprised by two coats “FLEXCOAT W500”

and one layer “MP Mesh A900” in between coats.

D) Apply one coat “SEALCOAT W501” as primer coat to all substrate and allow at least 45 mins for curing before

application of onward FLEXCOAT W500 System.

4.22 Laying of Waterproofing System:

:

A) Apply 2 coats “FLEXCOAT W500” with total thickness of not less than 0.4 mm.

B) It can be applied by roller, brush etc.

C) It can be applied by using special roller to obtain a texture appearance.

D) It can be covered by other acrylic paints. Please consult technical department of Master Proofer for suitable choice

of paint.

5.0 Material Coverage Horizontal surface (2 coat + 1 layer Mp mesh ): @2.0kg/m

2 approx.

Vertical surface (2 coat not less than 0.4mm): @0.8kg/m2 approx.

Actual consumption may be varying from surface conditions.

6.0 Health and Safety FLEXCOAT W500 is water- based material. It is non-toxin and no safety label.

Page 3: FLEXCOAT W500mphk123.weebly.com/uploads/3/1/3/7/31378773/w500-147.04.pdf · T-017-05 T-025-06 UTM: T-019-2 UTM: T-019-2 - Hardness Tester T-102-1 - - - - - - - - 3.0 Typical Application

FLEXCOAT W500

Acrylic Waterproofing Coating

www.labondhk.com Member Of Master Proofer Corporation LTD www.labondhk.com Control Reference: TCH/W500/295.06 Version:06 page 3 / 4

7.0 Typical Diagrams

8.0 Packaging 5kg/Drum / 20 kg/Drum is generally available at your nearest Master Proofer’s operation office.

9.0 Technical Advisory Notes 1. For liquid applied membrane, it may sometimes encounter problem of “Blisters” due to trapped air on rough concrete or

moisture vapour which are sometimes practically unavoidable. Provided that the blister are in low scale and they are

not punctured, it is unlikely to affect the overall performance of the system.

2. Primers are sometimes required to improve the adhesion between FLEXCOAT W500 and surface substrate, likes

bituminous surface, non-ferrous metal and exceptionally porous substrate. Applicator should consult our technical

office for necessary recommendation.

3. FLEXCOAT W500 is suitable for exposed roofing system only. In case of covered roofing system is required, it is

recommended to consider another products of LABOND Range: Thanecoat W300 or W302. Please refer to our

product brochure or call our Marketing Office for details.

END

Page 4: FLEXCOAT W500mphk123.weebly.com/uploads/3/1/3/7/31378773/w500-147.04.pdf · T-017-05 T-025-06 UTM: T-019-2 UTM: T-019-2 - Hardness Tester T-102-1 - - - - - - - - 3.0 Typical Application

FLEXCOAT W500

Acrylic Waterproofing Coating

www.labondhk.com Member Of Master Proofer Corporation LTD www.labondhk.com Control Reference: TCH/W500/295.06 Version:06 page 4 / 4

清理地面

Flo

or

Cle

anin

g

填平凹凸面

Re-

lev

elin

g U

nev

en

Su

rfac

e

掃上低油

Ap

ply

Pri

mer

拌均物料

Ho

mo

gen

eou

s

Mat

eria

l

用毛卷施工

Ap

ply

By

To

ol

Page 5: FLEXCOAT W500mphk123.weebly.com/uploads/3/1/3/7/31378773/w500-147.04.pdf · T-017-05 T-025-06 UTM: T-019-2 UTM: T-019-2 - Hardness Tester T-102-1 - - - - - - - - 3.0 Typical Application

www.labondhk.com Member Of Master Proofer Corporation LTD www.labondhk.com

LABOND Range of products are designed, manufactured and supplied by MASTER PROOFER COMPANY LTD

Head Office: 139A Hung UK Tsuen, Ping Shan, Yuen Long, N.T., Hong Kong

Tel :(852)2609 2300 Fax:(852) 2609 2309 E-mail:[email protected]

Every endeavor has been made to ensure that the information given herein is true and reliable, but it is given only for the guidance of our customers. The Company cannot accept any responsibility for loss or damage or

infringement of patent right that may result from the use of the information, due to the possibility of variations of processing or working conditions and of workmanship outside our control.. Users are advised to

Confirm the suitability of the products with their own tests. Any dimensions shown are approximate. Form-S1.1 960401

Form-MKT/LABF/341.01

Control Reference: TCH/W500/147.04 Version:04 page 1 / 3

FLEXCOAT W500

Acrylic Waterproofing Coating

單組份液態應用式丙稀酸防水塗膜

1.0 簡介

立康 W500 是一種單組份丙稀酸高效能防水塗膜。它是依照萬寶建築化工指定的配方規格製造。 立康 W500 是

膠漿狀,適用於平面及企身面。膠漿凝固後成為具有高彈性,高度抗紫外線老化及耐侯性的防水層。由於以上

特性,立康 W500 是種良好“全外露式”防水型材。

2.0 技術資料

*依據 MateriaLab 的測試報告 編號:040123ST40695 中,有關化驗所為 HOKLAS 計劃內認同化驗所。.

黏力強度 (不含底漆)

吸水率 %

抗拉強度

伸長度 (%)

Q-U-V 加速風化

硬度 (Shore A)

其他內部測試

可抗表裂紋

透濕度

凝固時間

施工溫度

耐火規格

煙霧抗散度

燃點

測試結果

0.75 - 1 N/mm2

2.31 %

2.34 N/mm2

152%

合格

63

> 2mm

34.288/m2/24hrs

12 hrs

5°- 40°C

zero

4

水溶性(非易燃物)

測試方法

ASTMD454:95

ASTMD570-81

ASTMD412-92

ASTMD412-92

ASTMG53-88

ASTMD2240-00

ASTMC836-89

ASTME96-94

-

-

AS1530 part 3

AS1530 part 3

-

設備

Pull-off Tester

T-017-05

T-025-06

UTM: T-019-2

UTM: T-019-2

-

Hardness Tester

T-102-1

-

-

-

-

-

-

-

3.0 一般應用範圍

立康 W500 是以吸收空氣水份凝固,它形成的膠模具備良好伸縮性及防水效能。它適用於新或舊天面、瓦磚面、

亢鈑頂、結構縫邊位等。 立康 W500 可施工於瀝青、水泥、金屬、石綿片、石材及石磚面等建築型材料上。

Page 6: FLEXCOAT W500mphk123.weebly.com/uploads/3/1/3/7/31378773/w500-147.04.pdf · T-017-05 T-025-06 UTM: T-019-2 UTM: T-019-2 - Hardness Tester T-102-1 - - - - - - - - 3.0 Typical Application

FLEXCOAT W500

Acrylic Waterproofing Coating

www.labondhk.com Member Of Master Proofer Corporation LTD www.labondhk.com Control Reference: TCH/W500/147.04 Version:04 page 2 / 3

4.0 施工細節

4.1 平面位置 (平面天台、瓦磚面、亢鈑蓋面、露台、水槽、結構夾縫位等)

4.11 施工面處理:

A) 施工面上的塵埃,油脂油及污漬必須清除。

B) 石屎面需平坦,如有需要先做一層英泥沙漿面將凹凸平整。

C) 施工面上低於 1-6mm 的非結構性裂痕先用一層立康 W500 處理。

D) 所有直角型碰口式地腳位須用水泥沙填妥。

E) 遇施工面屬於疏鬆及 “粉面” 化,可先塗一層立康 W501 作底油以加強立康 W500 與石屎

面的結合強度。

4.12 平面防水系統結構

F) 兩層立康 W500 加一層 MPMesh A900 不織布作中間夾層。

G) 可用油掃,油卷施工。

4.2 企身位置 (外牆,女兒牆等)

4.21 施工面處理

A) 依照 4.11 中的 ABC 步驟。

B) 其它活動型裂縫需塗兩層立康 W500 加一層 MPMesh A900 作為夾層。

C) 塗上一層立康 W501 作底油層並等待起碼 45 分鐘後才作下一步施工。

4.22 企身面防水結構

D) 塗上兩層不少 0.4mm 厚度的立康 W500。

E) 可用油掃或油卷施工。

F) 如需要花紋外觀亦可用特殊油卷做花紋面。

G) 可塗上其它類型的丙稀酸油漆作裝飾用。

5.0 用量指引

平面 (2 層 + 1 層不織布) : - 大概 2.0 公斤 / m2。

企身面 (2 層不少於 0.4mm 厚度: - 大概 0.8 公斤 / m2。

實際用量視乎施工面情況

6.0 健康與安全

立康 W500 是水溶性及非毒害性物料。

Page 7: FLEXCOAT W500mphk123.weebly.com/uploads/3/1/3/7/31378773/w500-147.04.pdf · T-017-05 T-025-06 UTM: T-019-2 UTM: T-019-2 - Hardness Tester T-102-1 - - - - - - - - 3.0 Typical Application

FLEXCOAT W500

Acrylic Waterproofing Coating

www.labondhk.com Member Of Master Proofer Corporation LTD www.labondhk.com Control Reference: TCH/W500/147.04 Version:04 page 3 / 3

7.0 Typical Diagrams:

8.0 包裝

5 公斤/桶 / 20 公斤/桶 / 25 公斤/桶是常備現貨規格。

9.0 其它技術意見.

凡是液態式塗膜,由於石屎內的水氣蒸發.在施工時會出現不同程度的“水泡”現象。只須要出現“水泡”程

度不大及它們未被刺穿,整體防水系統效能是不會被影嚮。

在某些施工面例如“非鐵金屬面、疏鬆石屎面等,應採用底油以加強黏合效果。

立康 W500 只適宜做一個“暴露式”(即防水層不蓋上水泥、瓦磚等)天面。 如需將防水層蓋於水泥瓦磚下,

客戶可以應用另外一種聚胺脂 (立康 W300 或 W302)防水塗膜,詳情參考有關資料。