flexible & pliable conduit systems to return to adaptaflex ... · – – pg7 sp10/pg7/a m16...

44
Flexible & Pliable Conduit Systems

Upload: others

Post on 14-Oct-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

Flexible & PliableConduit Systems

Notes
To return to Adaptaflex Presenter simply Quit out of Acrobat. Note Use the Contents Page to Select a Page
Page 2: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

Customer confidence

Over 25 years, Adaptaflex has built an enviable

reputation for providing reliable, safe and cost

effective flexible and pliable conduit systems that

our customers specify and install time and again,

with complete confidence.

Customer choice

At our development, manufacturing and

commercial centre in Coleshill near Birmingham

in the UK, continuous investment in people and

technology gives Adaptaflex the edge to

innovate, design and produce the market leading

products which enable our customers to choose

exactly the right system for the job in hand. The

extent of this choice is illustrated by the typically

diverse and demanding applications shown

alongside each of the Adaptaflex systems

featured in this catalogue.

For advice on matching the right Adaptaflex

system to your application, call the Adaptaflex

Infoline, we’ll be pleased to help.

01675

468202

ADAPTAFLEXIN

FOL

INE

Quality system ASTA certified

Page 3: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

FLEXIB

LEPL

IABLE

HIGH

MEC

HANI

CAL

STREN

GTH

EMI S

CREE

NLO

W FIR

E HAZ

ARD

HALO

GEN

FREE

HIGH

FATIG

UE LI

FEHI

GH A

BRAS

ION

RESIS

TANC

EHI

GH U

VRE

SISTA

NCE

COND

UIT T

YPE

ADAPTASTEELSTEEL FLEXIBLE SYSTEMS 4

ADAPTAFLEX IN ACTION 2

CUTTING TOOLS & ACCESSORIES 31

PERFORMANCE CHARACTERISTICS 34CONDUIT & FITTING MATERIALS 36CHEMICAL RESISTANCE 37EN50086 CLASSIFICATIONS 38THREAD DATA, IP RATINGS & 39CABLE CARRYING CAPACITY

INTERNATIONAL APPROVALS 40EMI SCREEN SYSTEMS 41& GLOSSARY

CONTENTSQUICK SELECTOR 1

NON-METALLIC FLEXIBLE SYSTEMS 14COMPATIBLE WITH:

ADAPTALOK IP66 SYSTEM 16ADAPTASEAL IP67 SYSTEM 22ADAPTARING IP40 SYSTEM 24

HI-SPECFLEXIBLE SYSTEMS 26

KORIFITNON-METALLIC PLIABLE SYSTEMS 28XTRAFLEXNON-METALLIC FLEXIBLE SYSTEM 30

STAYFLEXPLIABLE SYSTEM 13

ADAPTASTEELCOVERED STEEL FLEXIBLE SYSTEMS 6

ADAPTASTEELOVERBRAIDED STEEL 10FLEXIBLE SYSTEMSHIGH STRENGTH OVERBRAIDED STEEL SYSTEM 12

ADAPTASTEELLIQUID TIGHT COVERED STEEL 8FLEXIBLE SYSTEMS

METALLIC SYSTEMS

NON-METALLIC SYSTEMS

TEMPE

RATU

RERA

NGE (

°C)

MIN MAX IP40 IP54 IP65 IP66 IP67

✓ – ✓ – ✓ ✓ ✓ – ✓ -50 300 ✓ – – – – S✓ – ✓ – ✓ ✓ ✓ ✓ ✓ -50 300 ✓ – – – – SS

✓ – ✓ – – – – – ✓ -15 70 – ✓ ✓ – – SP✓ – ✓ – – ✓ – ✓ ✓ -40 120 – ✓ ✓ – – SN✓ – ✓ – ✓ ✓ – – ✓ -25 90 – ✓ ✓ – – LFH-SP

✓ – ✓ – – – – – ✓ -20 105 – – – – ✓ SPL✓ – ✓ – – – – – ✓ -15 70 – – – – ✓ SPLE✓ – ✓ – – ✓ ✓ – ✓ -65 135 – – – – ✓ SPLHC✓ – ✓ – – – – – ✓ -15 75 – – – – ✓ SPUL

✓ – ✓ ✓ ✓ ✓ ✓ ✓ ✓ -50 300 ✓ – – – – SB✓ – ✓ ✓ ✓ ✓ ✓ ✓ ✓ -50 300 ✓ – – – – STC✓ – ✓ ✓ – – – ✓ ✓ -15 70 – ✓ – – – SPB✓ – ✓ ✓ – – – ✓ ✓ -15 70 – ✓ – – – SPTC✓ – ✓ ✓ – ✓ ✓ ✓ ✓ -65 135 – – – – ✓ SPLHCB

– ✓ – ✓ – – – – ✓ -15 70 – – – – ✓ LSP

✓ – – – – ✓ ✓ – – -40 120 ✓ – – ✓ ✓ PA LIGHT✓ – – – ✓ ✓ ✓ ✓ ✓ -40 120 ✓ – – ✓ ✓ PA STANDARD✓ – – – ✓ ✓ – ✓ ✓ -40 120 ✓ – – ✓ ✓ PA MEDIUM✓ – – – ✓ ✓ – ✓ ✓ -40 120 ✓ – – ✓ ✓ PA HEAVY✓ – – – ✓ ✓ ✓ ✓ ✓ -40 120 ✓ – – ✓ ✓ PR✓ – – – – ✓ ✓ – – -50 90 ✓ – – ✓ ✓ PI✓ – – – – ✓ ✓ – – -20 90 ✓ – – ✓ ✓ PP

✓ – – – ✓ ✓ ✓ – ✓ -60 250 – – – – ✓ PK✓ – ✓ ✓ ✓ ✓ ✓ ✓ ✓ -60 250 – – – – ✓ PKTC✓ – ✓ ✓ ✓ ✓ ✓ ✓ ✓ -60 250 – – – – ✓ PKSS✓ – – ✓ ✓ ✓ ✓ ✓ ✓ -40 120 – – – – ✓ PRTC✓ – – ✓ ✓ ✓ ✓ ✓ ✓ -40 120 – – – – ✓ PRSS

– ✓ – – – – – – ✓ -5 60 ✓ – ✓ – – KFL– ✓ – – – – – – ✓ -5 60 ✓ – ✓ – – KFS– ✓ – – – – – – ✓ -5 60 ✓ – ✓ – – KFM✓ – – – – – – – ✓ -5 60 – – ✓ – – XF

Quick Selector Contents Page

AVAIL

ABLE

IP PR

OTEC

TION

Page 4: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

A look at what’s new from theleading company in flexible andpliable conduit systems…

Our continued policy of new product development, inline with worldwide market requirements has resultedin the printing of this, our new product catalogue.

The global market for flexible conduit systemscontinues to move towards non-metallic systems, andthis is reflected in the many new products in thispublication. However, the more traditional metallicconduit systems continue to be very important forAdaptaflex, with new developments being introducedto widen the application of these systems.

Market Changes

Recently the most significant changes in our markethave been the introduction of new Internationalstandards, namely, the European Standard EN50086which specifies performances for conduit systems forelectrical installations, and the EC directives forelectromagnetic compatibility (EMC).

Since Adaptaflex has representatives involved in writingthese new standards, you can be assured that theproducts you are buying represent the very latest indesign philosophies.

For example, we introduce a whole new range of Hi-Spec products for specialised applications, wherefire and toxic fume risks are of particular concern orwhere electromagnetic interference (EMI) screening of conduit is called for. To help recognise these special properties we have introduced a set of symbolswhich allow you, at a glance, to see the varying degreesof performance.

2

01675

468202

ADAPTAFLEX-IN

FOL

INE

ADAPTAFLEX IN ACTIONWHAT ARE WE DOING FOR YOU?

Extended Adaptalok Range

Adaptalok, the non-metallic conduit system with ‘push-on’ fittings is now recognised as being the lowestinstalled cost system due to how quickly it can beassembled together. Now, to add more versatility weintroduce a unique range of swivel, brass threadedAdaptalok fittings with their increased strength makingthem more suitable when a high tightening torque isnecessary. Swivel elbows offer a particular benefit whenused with threaded entries, since they can beaccurately positioned after installation.

EMI

S

CR

EE

N•

E

MI S C R EEN

•E

MI

SC

R

EEN•

STANDARD LO

W

FIRE HAZ

AR

DLFH•LO

W

FIRE HAZAR

D•

New Adaptaring System

For rotating or rapid motion applications, like roboticinstallations, new Adaptaring fittings incorporate afreely rotating C-ring allowing unrestricted movement,specifically designed for these particular circumstances.

Page 5: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

3

Available near you

Adaptaflex is as close as your local Electrical stockist,since over 5000 of them in more than 40 countriessupply Adaptaflex products to installers, machineconstructors and panel builders alike.

Adaptaflex subsidiaries in Australia and Germany, aswell as our international network of agents,demonstrate our commitment to expansion in supportof existing and potential Adaptaflex Customers,wherever they may be.

Working Together

Our Customers are always welcome to draw on theAdaptaflex expertise in all aspects of design,manufacture, and application of flexible and pliableconduit systems. Our sales team, fully supported byin-house marketing, technical, material and projectspecialists, await your call to the Adaptaflex Infolineon (+44) 01675 468202.

Technical Support

To assist specifiers we now provide more compre-hensive technical support details located at the back ofthe catalogue. Of course you could also phone ourinside sales support team, who are trained to help youapply our products correctly.

Customer Special Orders

Customers sometimes prefer to order pre-assembledconduit systems, when a number of assemblies to thesame specification are required or when the integrityand performance of more specialised systems must beassured.

Our optional in-house assembly service givesAdaptaflex Customers the freedom to have morespecialised products designed or customised toindividual specifications.

Always rememberwho’s got the widest range…

Page 6: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

4

STEEL FLEXIBLE SYSTEMSTYPE S – GENERAL PURPOSE, GALVANISED STEEL, INHERENT LOW FIRE HAZARD TYPE SS – CORROSION RESISTANT, STAINLESS STEEL, INHERENT LOW FIRE HAZARD

Conduit

S10 – 9.0 6.8 25

S12 SS12 13.0 10.3 30

S16 SS16 16.0 13.0 35

S16 SS16 16.0 13.0 35

S20 SS20 20.5 16.9 45

S25 SS25 25.0 21.4 55

S32 SS32 32.0 28.1 60

S40 – 42.5 37.7 80

S50 – 53.0 48.4 90

S63 – 62.5 57.5 115

S75 – 77.0 70.0 150

Fittings

– – PG7 S10/PG7/A

M16 S12/M16/A PG9 S12/PG9/A

M16 S16/M16/A PG11 S16/PG11/A

M20 S16/M20/A PG11 S16/PG11/A

M20 S20/M20/A PG16 S20/PG16/A

M25 S25/M25/A PG21 S25/PG21/A

M32 S32/M32/A PG29 S32/PG29/A

M40 S40/M40/A PG36 S40/PG36/A

M50 S50/M50/A PG42 S50/PG42/A

M63 S63/M63/A PG48 S63/PG48/A

M75 S75/M75/A – –

TYPES S & SS TYPE A IP40STRAIGHT FITTING – FIXED EXTERNAL THREADfor insertion into knockouts using a locknut

TYPE B IP40STRAIGHT FITTING – SWIVEL EXTERNAL THREADfor insertion into threaded entries & knockouts

TYPE S

PART NUMBER

TYPE SS

PART NUMBER

PART

NUMBERMETRIC

THREAD

PART

NUMBERPGTHREA

D

M10 S10/M10/B PG7 S10/PG7/B

M16 S12/M16/B PG9 S12/PG9/B

M16 S16/M16/B PG11 S16/PG11/B

M20 S16/M20/B PG11 S16/PG11/B

M20 S20/M20/B PG16 S20/PG16/B

M25 S25/M25/B PG21 S25/PG21/B

M32 S32/M32/B PG29 S32/PG29/B

M40 S40/M40/B PG36 S40/PG36/B

M50 S50/M50/B PG42 S50/PG42/B

– – – –

– – – –

PART

NUMBERMETRIC

THREAD

PART

NUMBERPGTHREA

DOUTSI

DE

DIAMETE

R mm

INSIDE

DIAMETE

R mm

MINIMUM BEND

RADIUS m

m

01675

468202

ADAPTAFLEX-IN

FOL

INE

◆ TYPE BThread swivels for easy installation

◆ FITTINGNickel plated brass components

◆ CONDUITHelically wound steel stripTYPE S Galvanised steelTYPE SS Stainless steel

LO

W

FI R E H A

ZA

RDILFH•

INHEREN

T•

Page 7: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

5

AccessoriesTYPE C IP40SMOOTH ENTRY BUSHfor locking conduit into plain holes inenclosures

TYPE F IP40STRAIGHT FITTING – FIXED INTERNAL THREADfor attachment to external threads & other fittings

9 S10/9/C

12 S12/12/C

16 S16/16/C

16 S16/16/C

20 S20/20/C

25 S25/25/C

32 S32/32/C

40 S40/40/C

51 S50/51/C

61 S63/61/C

– –

– –

– –

– –

– –

M20 S20/M20/F

M25 S25/M25/F

M32 S32/M32/F

– –

– –

– –

– –

PART

NUMBERHOLE

SIZE m

mPAR

T

NUMBERMETRIC

THREAD

TYPE PP-CLIP CONDUIT SUPPORTPlated steel construction with PVC insert

10 P CLIP/10

12 P CLIP/12

16 P CLIP/16

16 P CLIP/16

20 P CLIP/20

25 P CLIP/25

32 P CLIP/32

40 P CLIP/40

50 P CLIP/50

63 P CLIP/63

75 P CLIP/75

PART

NUMBERNOMINAL

CONDUIT S

IZE

Plain steel systems are inherently low fire hazard (ILFH) andoffer high flexibility and mechanical strength where low levelingress protection is sufficient.

Type S is widely used in dry, internal installations e.g.Underfloor wiring whereas Type SS is particularly suitable forwet or corrosive environments or severe temperaturefluctuations.

FROM ADAPTAFLEX

● See pages 34 - 41 for Technical Details

● See pages 31 - 33 for Cutting Tools and Accessories

● Minimum bend radius is minimum inside bend radius in static mode

Approvals may be limited to certain products, see approvals on page 40.

BS EN 50086

Page 8: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

6

LIQUID RESISTANT COVERED STEELFLEXIBLE SYSTEMSTYPE SP – GENERAL PURPOSE, PVC COVEREDTYPE SN – ABRASION & SOLVENT RESISTANT, HALOGEN FREE, POLYAMIDE (NYLON) COVEREDTYPE LFH-SP – ENHANCED LOW FIRE HAZARD, POLYOLEFIN COVERED

Conduit

SP10 – – 10.0 6.8 25

SP12 SN12 – 14.0 10.3 30

SP16 SN16 LFH-SP16 17.0 13.0 35

SP16 SN16 LFH-SP16 17.0 13.0 35

SP20 SN20 LFH-SP20 21.5 16.9 45

SP25 SN25 LFH-SP25 26.0 21.4 55

SP32 SN32 LFH-SP32 34.0 28.1 60

SP40 – LFH-SP40 44.5 37.7 80

SP50 – LFH-SP50 55.0 48.4 90

SP63 – – 64.5 57.5 115

SP75 – – 79.0 70.0 150

Fittings

– – PG7 SP10/PG7/A

M16 SP12/M16/A PG9 SP12/PG9/A

M16 SP16/M16/A PG11 SP16/PG11/A

M20 SP16/M20/A PG11 SP16/PG11/A

M20 SP20/M20/A PG16 SP20/PG16/A

M25 SP25/M25/A PG21 SP25/PG21/A

M32 SP32/M32/A PG29 SP32/PG29/A

M40 SP40/M40/A PG36 SP40/PG36/A

M50 SP50/M50/A PG42 SP50/PG42/A

M63 SP63/M63/A PG48 SP63/PG48/A

M75 SP75/M75/A – –

TYPES SP, SN & LFH-SP TYPE A IP54STRAIGHT FITTING – FIXED EXTERNAL THREADfor insertion into knockouts using a locknut

TYPE B IP54STRAIGHT FITTING – SWIVEL EXTERNAL THREADfor insertion into threaded entries & knockouts

TYPE SP

PART NUMBER

TYPE SN

PART NUMBER

TYPE LFH

-SP

PART NUMBER

PART

NUMBERMETRIC

THREAD

PART

NUMBERPGTHREA

D

M10 SP10/M10/B PG7 SP10/PG7/B

M16 SP12/M16/B PG9 SP12/PG9/B

M16 SP16/M16/B PG11 SP16/PG11/B

M20 SP16/M20/B PG11 SP16/PG11/B

M20 SP20/M20/B PG16 SP20/PG16/B

M25 SP25/M25/B PG21 SP25/PG21/B

M32 SP32/M32/B PG29 SP32/PG29/B

M40 SP40/M40/B PG36 SP40/PG36/B

M50 SP50/M50/B PG42 SP50/PG42/B

– – – –

– – – –

PART

NUMBERMETRIC

THREAD

PART

NUMBERPGTHREA

DOUTSI

DE

DIAMETE

R mm

INSIDE

DIAMETE

R mm

MINIMUM BEND

RADIUS m

m

01675

468202

ADAPTAFLEX-IN

FOL

INE

◆ TYPE BThread swivels toassist installation

◆ FITTINGNickel plated brass components

◆ CONDUITHelically wound galvanised steel strip

◆ PROTECTIVE COVERINGTYPE SP PVC in black, (grey or orange made to order)TYPE SN Polyamide (Nylon) in blackTYPE LFH-SP Polyolefin in black

LO

W

FI R E H A

ZA

RDELFH•

E

NHANCE

D•

Page 9: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

7

TYPE C IP54SMOOTH ENTRY BUSHfor locking conduit into plainholes in enclosures

TYPE F IP54STRAIGHT FITTING – FIXED INTERNAL THREADfor attachment to externalthreads & other fittings

9 SP10/9/C

12 SP12/12/C

16 SP16/16/C

16 SP16/16/C

20 SP20/20/C

25 SP25/25/C

32 SP32/32/C

40 SP40/40/C

51 SP50/51/C

61 SP63/61/C

– –

– –

– –

– –

– –

M20 SP20/M20/F

M25 SP25/M25/F

M32 SP32/M32/F

– –

– –

– –

– –

PART

NUMBERHOLE

SIZE m

m

TYPE ECONDUIT TERMINATORfor protecting cables atpoint of exit from conduit

SP12/E

SP16/E

SP16/E

SP20/E

SP25/E

SP32/E

PART

NUMBERPART

NUMBERMETRIC

THREAD

TYPE M IP65STRAIGHT SWIVEL FITTING – EXTERNAL THREADfor insertion into threaded entries & knockoutsFitting swivels independently of conduit until tightened to assist installation.

– – – – – –

M16 SP12/M16/M PG9 SP12/PG9/M – –

M16 SP16/M16/M PG11 SP16/PG11/M 3/8 SP16/038/M

M20 SP16/M20/M PG13.5 SP16/PG13/M 3/8 SP16/038/M

M20 SP20/M20/M PG16 SP20/PG16/M 1/2 SP20/050/M

M25 SP25/M25/M PG21 SP25/PG21/M 3/4 SP25/075/M

M32 SP32/M32/M PG29 SP32/PG29/M 1 SP32/100/M

– – – – – –

– – – – – –

– – – – – –

– – – – – –

PART

NUMBER PART

NUMBERMETRIC

THREAD

PGTHREA

DPAR

T

NUMBERNPTTHREA

D

These versatile systems meet the limited dynamic or staticand weatherproof requirements of most industrial andcommercial applications.

Type SP is widely used in combination with rigid conduitand trunking, whilst halogen-free Type SN provides theenhanced resistance to solvents and abrasion over a widertemperature range.

The flame retardant, low smoke density and toxicityproperties of halogen-free Type LFH-SP complement FirePerformance cable where public safety is of concern, e.g.in Hospitals, Shopping & Leisure centres and UndergroundRailways.

FROM ADAPTAFLEX

Approvals may be limited to certain products, see approvals on page 40.

BS EN 50086

● See pages 34 - 41 for Technical Details

● See pages 31 - 33 for Cutting Tools and Accessories

● Minimum bend radius is minimum inside bend radius in static mode

● See page 5 for P-Clip conduit support

Page 10: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

Conduit

SPL10 SPLE10 – – 1/4” 10 11.8 7.0 40

SPL12 SPLE12 – – 5/16” 12 14.2 10.0 45

SPL16 SPLE16 SPLHC16 SPUL16 3/8” 16 17.8 12.5 50

SPL16 SPLE16 SPLHC16 SPUL16 3/8” 16 17.8 12.5 50

SPL20 SPLE20 SPLHC20 SPUL20 1/2” 20 21.1 15.9 80

SPL25 SPLE25 SPLHC25 SPUL25 3/4” 25 26.4 21.0 110

SPL32 SPLE32 SPLHC32 SPUL32 1” 32 33.1 26.7 145

SPL40 SPLE40 SPLHC40 SPUL40 11/4” 40 41.8 35.4 180

SPL50 SPLE50 SPLHC50 SPUL50 11/2” 50 47.9 40.4 240

SPL63 SPLE63 SPLHC63 SPUL63 2” 63 59.7 51.6 345

FittingsTYPES SPL, SPLE, SPLHC & SPUL

TYPE S

PL

PART N

UMBER

TYPE S

PLE

PART N

UMBER

TYPE S

PLHC

PART N

UMBER

TYPE S

PUL

PART N

UMBER

US TRAD

E SIZE

UK TRAD

E SIZE

OUTSIDE

DIAMETE

R mm

INSIDE

DIAMETE

R mm

MINIMUM**

BEND RA

DIUS mm

8

LIQUID TIGHT COVERED STEEL FLEXIBLE SYSTEMSTYPE SPL – HIGH & LOW TEMPERATURE, OIL RESISTANT, PVC COVEREDTYPE SPLE – GENERAL PURPOSE, PVC COVEREDTYPE SPLHC – EXTREME TEMPERATURE, THERMOPLASTIC RUBBER COVEREDTYPE SPUL – UL LISTED, CSA APPROVED, PVC COVERED

TYPE M IP67STRAIGHT SWIVEL FITTING – EXTERNAL THREADfor insertion into threaded entries & knockouts

M16 SPL10/M16/M PG7 SPL10/PG7/M – –

M16 SPL12/M16/M PG9 SPL12/PG9/M – –

M16 SPL16/M16/M PG11 SPL16/PG11/M 3/8 SPL16/038/M

M20 SPL16/M20/M PG13.5 SPL16/PG13/M 3/8 SPL16/038/M

M20 SPL20/M20/M PG16 SPL20/PG16/M 1/2 SPL20/050/M

M25 SPL25/M25/M PG21 SPL25/PG21/M 3/4 SPL25/075/M

M32 SPL32/M32/M PG29 SPL32/PG29/M 1 SPL32/100/M

M40 SPL40/M40/M PG36 SPL40/PG36/M 11/4 SPL40/125/M

M50 SPL50/M50/M PG42 SPL50/PG42/M 11/2 SPL50/150/M

M63 SPL63/M63/M PG48 SPL63/PG48/M – –

PART

NUMBER PART

NUMBERMETRIC

THREAD

PGTHREA

DPAR

T

NUMBERNPTTHREA

D

01675

468202

ADAPTAFLEX-IN

FOL

INE

◆ TYPE MThread swivels independently of conduituntil tightened to assist installation

◆ FITTINGNickel plated brass components

◆ CONDUITHelically wound galvanised steel strip

◆ Insulated throatprotects cables

◆ Face seal

◆ Liquid tight seal

◆ SMOOTH COVERINGTYPE SPL PVC in black (grey or orange made to order)TYPE SPLE PVC in black (grey made to order)TYPE SPLHC Thermoplastic rubber in blackTYPE SPUL PVC in grey

**not applicable to SPUL

Page 11: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

AccessoriesTYPE A IP67STRAIGHT FITTING – FIXED EXTERNAL THREADfor insertion into knockoutsusing a locknut

TYPE B IP67STRAIGHT FITTING – SWIVEL EXTERNAL THREADfor insertion into threaded entries & knockouts

M16 SPL10/M16/A

M16 SPL12/M16/A

M16 SPL16/M16/A

M20 SPL16/M20/A

M20 SPL20/M20/A

M25 SPL25/M25/A

M32 SPL32/M32/A

– –

– –

– –

PART

NUMBERMETRIC

THREAD

– – – –

– – – –

M16 SPL16/M16/B PG11 SPL16/PG11/B

M20 SPL16/M20/B PG13.5 SPL16/PG13/B

M20 SPL20/M20/B PG16 SPL20/PG16/B

M25 SPL25/M25/B PG21 SPL25/PG21/B

M32 SPL32/M32/B PG29 SPL32/PG29/B

– – – –

– – – –

– – – –

PART

NUMBERMETRIC

THREAD

PART

NUMBERPGTHREA

D

9

M16 B/M16/90

M16 B/M16/90

M16 B/M16/90

M20 B/M20/90

M20 B/M20/90

M25 B/M25/90

M32 B/M32/90

PART

NUMBERMETRIC

THREAD

– –

– –

M16* B/M16/45

M20 B/M20/45

M20 B/M20/45

M25 B/M25/45

M32 B/M32/45

PART

NUMBERMETRIC

THREAD

TYPE ECONDUIT TERMINATORfor protecting cablesat point of exit fromconduit

SPL10/E

SPL12/E

SPL16/E

SPL16/E

SPL20/E

SPL25/E

SPL32/E

SPL40/E

SPL50/E

SPL63/E

PART

NUMBER

UL recognised & Lloyds approved liquid tight system TypeSPL is typically found in Machining, Processing or Handlingenvironments requiring assured high mechanical strength,oil resistance & ingress protection where highertemperatures may predominate.

Type SPLE meets more general purpose liquid tightrequirements whilst Type SPLHC is particularly suited toextremes of temperature.

Type SPUL is both UL listed & CSA approved for extremetemperature, liquid tight applications.

FROM ADAPTAFLEX

Approvals may be limited to certain products, see approvals on page 40.

*incorporates M20 internal thread

For alternative PG and NPT threaded elbows see page 32.

TYPE 45 IP6745° ELBOW – FIXED INTERNAL& EXTERNAL THREADnickel plated brass

● See pages 34 - 41 for Technical details

● See pages 31 - 33 for Cutting Tools and Accessories

● See page 5 for P-Clip Conduit Support

● Minimum bend radius is minimum inside bend radius in static mode

TYPE 90 IP6790° ELBOW – FIXED INTERNAL& EXTERNAL THREADnickel plated brass

BS EN 50086

Page 12: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

Conduit

SB10 STC10 10.0 6.8 25

SB12 STC12 14.0 10.3 30

SB16 STC16 17.5 13.0 35

SB20 STC20 21.5 16.9 45

SB25 STC25 26.0 21.4 55

SB32 STC32 34.0 28.1 60

SB40 STC40 43.6 37.7 80

SB50 STC50 56.0 48.4 90

Fittings

PG7 SB10/PG7/A

M16 SB12/M16/A

M16 SB16/M16/A

M20 SB20/M20/A

M25 SB25/M25/A

M32 SB32/M32/A

M40 SB40/M40/A

M50 SB50/M50/A

M10 SB10/M10/B PG7 SB10/PG7/B

M16 SB12/M16/B PG9 SB12/PG9/B

M16 SB16/M16/B PG11 SB16/PG11/B

M20 SB20/M20/B PG16 SB20/PG16/B

M25 SB25/M25/B PG21 SB25/PG21/B

M32 SB32/M32/B PG29 SB32/PG29/B

M40 SB40/M40/B PG36 SB40/PG36/B

M50 SB50/M50/B PG42 SB50/PG42/B

TYPES SB & STC TYPE A IP40STRAIGHT FITTING – FIXED EXTERNAL THREADfor insertion into knockouts using a locknut

TYPE B IP40STRAIGHT FITTING – SWIVEL EXTERNAL THREADfor insertion into threaded entries & knockouts

TYPE S

B

PART N

UMBER

TYPE S

TC

PART N

UMBER

PART

NUMBER

THREAD

PART

NUMBERMETRIC

THREAD

PART

NUMBERPGTHREA

DOUTSI

DE

DIAMETE

R mm

INSIDE

DIAMETE

R mm

MINIMUM

BEND RA

DIUS mm

10

OVERBRAIDED STEEL FLEXIBLE SYSTEMSTYPE SB – ABRASION RESISTANT, ENHANCED EMI SCREEN, GALVANISED STEEL OVERBRAIDEDTYPE STC – HIGH EMI SCREEN, TINNED COPPER OVERBRAIDED TYPE SPB – ABRASION & LIQUID RESISTANT, ENHANCED EMI SCREEN,

GALVANISED STEEL OVERBRAIDEDTYPE SPTC – LIQUID RESISTANT, HIGH EMI SCREEN, TINNED COPPER OVERBRAIDED

01675

468202

ADAPTAFLEX-IN

FOL

INE

◆ TYPE BThread swivels for easy installation

◆ FITTINGNickel plated brass components

◆ CONDUITHelically woundgalvanised steel strip

◆ TYPE SPB / TYPE SPTC Liquid resistant PVC covering

◆ PROTECTIVE OVERBRAIDTYPE SB / TYPE SPB Galvanised steelTYPE STC / TYPE SPTC Tinned Copper

EMI

S

CR

EE

N•

E

MI S C R EEN

•E

MI

SC

R

EEN•

ENHANCED

LO

W

FI R E H A

ZA

RDILFH•

INHEREN

T•

EMI

S

CR

EE

N•

E

MI S C R EEN

•E

MI

SC

R

EEN•

HIGH

Page 13: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

SPB10 SPTC10 11.0 6.8 25

SPB12 SPTC12 15.0 10.3 25

SPB16 SPTC16 18.5 13.0 30

SPB20 SPTC20 22.5 16.9 35

SPB25 SPTC25 28.0 21.4 55

SPB32 SPTC32 36.0 28.1 60

SPB40 SPTC40 45.5 37.7 80

SPB50 SPTC50 57.5 48.4 90

TYPE S

PB

PART N

UMBER

TYPE S

PTC

PART N

UMBER

OUTSIDE

DIAMETE

R mm

INSIDE

DIAMETE

R mm

MINIMUM BEND

RADIUS m

m

11

Conduit Fittings

PG7 SPB10/PG7/A

M16 SPB12/M16/A

M16 SPB16/M16/A

M20 SPB20/M20/A

M25 SPB25/M25/A

M32 SPB32/M32/A

M40 SPB40/M40/A

M50 SPB50/M50/A

M10 SPB10/M10/B PG7 SPB10/PG7/B

M16 SPB12/M16/B PG9 SPB12/PG9/B

M16 SPB16/M16/B PG11 SPB16/PG11/B

M20 SPB20/M20/B PG16 SPB20/PG16/B

M25 SPB25/M25/B PG21 SPB25/PG21/B

M32 SPB32/M32/B PG29 SPB32/PG29/B

M40 SPB40/M40/B PG36 SPB40/PG36/B

M50 SPB50/M50/B PG42 SPB50/PG42/B

TYPE A IP54STRAIGHT FITTING – FIXED EXTERNAL THREADfor insertion into knockouts using a locknut

TYPE B IP54STRAIGHT FITTING – SWIVEL EXTERNAL THREADfor insertion into threaded entries & knockouts

PART

NUMBER

THREAD

PART

NUMBERMETRIC

THREAD

PART

NUMBERPGTHREA

D

Overbraided flexible systems can contribute significantlyto the EMI screen requirements of installations covered bythe EMC Directive, in addition to providing enhancedresistance to abrasion & mechanical damage, e.g. in thevicinity of metal machining or welding equipment.

Type SB is widely used in dry, high temperatureenvironments whilst Type STC additionally offers a highlevel of EMI screen.

Type SPB adds weatherproofing and ingress protection togeneral applications whilst Type SPTC additionally meetshigh EMI screen specifications.

FROM ADAPTAFLEX

Approvals may be limited to certain products, see approvals on page 40.

BS EN 50086

TYPES SPB & SPTC

EMI

S

CR

EE

N•

E

MI S C R EEN

•E

MI

SC

R

EEN•

ENHANCED

EMI

S

CR

EE

N•

E

MI S C R EEN

•E

MI

SC

R

EEN•

HIGH

● See pages 34 - 41 for Technical details

● See pages 31 - 33 for Cutting Tools and Accessories

● See page 5 for P-Clip Conduit Support

● Minimum bend radius is minimum inside bend radius in static mode

Page 14: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

Conduit

SPLHCB16 19.8 12.5 80

SPLHCB16 19.8 12.5 80

SPLHCB20 23.1 15.9 95

SPLHCB25 28.4 21.0 115

SPLHCB32 35.1 26.7 145

SPLHCB40 43.8 35.4 180

SPLHCB50 49.9 40.4 240

FittingsTYPE SPLHCB TYPE B IP67

STRAIGHT FITTING – SWIVEL EXTERNAL THREADfor insertion into threaded entries & knockouts

PART

NUMBER

M16 SPLB16/M16/B PG11 SPLB16/PG11/B

M20 SPLB16/M20/B PG13.5 SPLB16/PG13/B

M20 SPLB20/M20/B PG16 SPLB20/PG16/B

M25 SPLB25/M25/B PG21 SPLB25/PG21/B

M32 SPLB32/M32/B PG29 SPLB32/PG29/B

– – – –

– – – –

PART

NUMBERMETRIC

THREAD

PART

NUMBERPGTHREA

D

TYPE A IP67STRAIGHT FITTING – FIXED EXTERNAL THREADfor insertion into knockouts using a locknut

M16 SPLB16/M16/A

M20 SPLB16/M20/A

M20 SPLB20/M20/A

M25 SPLB25/M25/A

M32 SPLB32/M32/A

M40 SPLB40/M40/A

M50 SPLB50/M50/A

PART

NUMBERMETRIC

THREAD

OUTSIDE

DIAMETE

R mm

INSIDE

DIAMETE

R mm

MINIMUM BEND

RADIUS m

m

12

LIQUID TIGHT HIGH STRENGTHOVERBRAIDED STEEL SYSTEMTYPE SPLHCB – HIGH & LOW TEMPERATURE, ABUSE RESISTANT,

STANDARD EMI SCREEN, STAINLESS STEEL OVERBRAIDED

01675

468202

ADAPTAFLEX-IN

FOL

INE

◆ TYPE BThread swivels for easy installation

◆ FITTINGNickel plated brass components

◆ CONDUITHelically wound galvanised steel strip

◆ Insulated throatprotects cables

◆ Face seal

◆ Liquid tight seal

◆ SMOOTH COVERINGThermoplastic rubber

◆ Braid clamp

◆ PROTECTIVE OVERBRAIDStainless steel

FROM ADAPTAFLEX

Liquid tight type SPLHCB is specifically designed to cope with the arduousdemands placed upon conduit systems within railway rolling stock & heavyindustrial applications by offering superior mechanical strength coupled witha high resistance to abrasion and extremes of temperature.

Approvals may be limited to certain products, see approvals on page 40.

BS EN 50086

EMI

S

CR

EE

N•

E

MI S C R EEN

•E

MI

SC

R

EEN•

STANDARD

Page 15: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

13

Conduit

LSP16 17.8 11.6 35

LSP16 17.8 11.6 35

LSP20 21.0 14.6 40

LSP25 27.3 20.4 50

LSP32 34.0 26.7 65

LSP40 40.4 32.8 80

Fittings Accessories

M16 LSP16/M16/A

M20 LSP16/M20/A

M20 LSP20/M20/A

M25 LSP25/M25/A

M32 LSP32/M32/A

M40 LSP40/M40/A

TYPE LSP TYPE A IP67STRAIGHT SWIVEL FITTING – FIXED THREADfor insertion into threaded entries & knockouts

PART

NUMBER PART

NUMBERMETRIC

THREAD

M16 B/M16/90

M20 B/M20/90

M20 B/M20/90

M25 B/M25/90

M32 B/M32/90

– –

PART

NUMBERMETRIC

THREAD

– –

– –

M20 LSPS20/M20/A

M25 LSPS25/M25/A

– –

– –

PART

NUMBERMETRIC

THREAD

M16* B/M16/45

M20 B/M20/45

M20 B/M20/45

M25 B/M25/45

M32 B/M32/45

– –

PART

NUMBERMETRIC

THREAD

OUTSIDE

DIAMETE

R mm

INSIDE

DIAMETE

R mm

MINIMUM

BEND RA

DIUS mm

LIQUID TIGHT PVC COVERED STEELPLIABLE SYSTEMTYPE LSP – GENERAL PURPOSE OR ENHANCED EMI SCREEN, STATIC APPLICATIONS

TYPE S IP67STRAIGHT SWIVEL SCREENFITTING – FIXED THREADfor insertion into threadedentries & knockouts

TYPE 90 IP6790° ELBOW – FIXED INTERNAL& FIXED EXTERNAL THREADNickel plated brass

TYPE 45 IP6745° ELBOW – FIXED INTERNAL& FIXED EXTERNAL THREADNickel plated brass

Pliable system Type LSP is widely used in conjunction with rigid conduitand trunking to provide wiring in general purpose, static applications,e.g. pumps, motors or workshop equipment, where a degree ofmechanical and good ingress protection are required.

Assemblies combining LSP conduit with Type S fittings can, in addition,contribute significantly to the EMI screen requirements of installationscovered by the EMC directive.

◆ TYPE SEMI screen fitting

◆ FITTINGNickel plated brasscomponents

◆ Liquid tight seal

◆ CONDUITHelically wound steel with kraftpaper liner

◆ TYPE SEMI screen ferrule

◆ SMOOTH COVERINGPVC in black

*Incorporates M20 internal thread

Approvals may be limited to certain products, see approvals on page 40.

BS EN 50086

EMI

S

CR

EE

N•

E

MI S C R EEN

•E

MI

SC

R

EEN•

ENHANCED

● See pages 34 - 41 for Technical details

● See pages 31 - 33 for Cutting Tools and Accessories

● See page 5 for P-Clip Conduit Support

● Minimum bend radius is minimum inside bend radius in static mode

Page 16: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

Conduit

14

01675

468202

ADAPTAFLEX-IN

FOL

INE

NON-METALLIC FLEXIBLE SYSTEMSTYPE PA – LOW FIRE HAZARD, POLYAMIDE (NYLON) 6TYPE PR – ENHANCED LOW FIRE HAZARD, MODIFIED POLYAMIDE (NYLON) 6TYPE PI – HIGH FLEXIBILITY, MODIFIED POLYAMIDETYPE PP – ACID RESISTANT, POLYPROPYLENE

10 10.0 FINE

13 13.0 FINE

16 15.8 FINE

18 18.5 FINE

20 20.0 COARSE

21 21.2 FINE

21 21.2 COARSE

25 25.0 COARSE

28 28.5 FINE

28 28.5 COARSE

34 34.5 FINE

34 34.5 COARSE

42 42.5 COARSE

54 54.5 COARSE

– – –

PAFL13 10.0 25

PAFL16 11.9 35

– – –

– – –

PAFL21 16.8 45

– – –

– – –

– – –

PACL28 22.2 50

– – –

PACL34 27.9 60

PACL42 35.2 65

PACL54 46.9 75

TYPE PALIGHT WEIGHT

NOMINAL

CONDUIT S

IZE

OUTSIDE

DIAMETE

R mm

PITCH

PART N

UMBER

INSIDE

DIAMETE

R mm

MINIMUM

BEND RA

DIUS mm

PART N

UMBER

INSIDE

DIAMETE

R mm

MINIMUM

BEND RA

DIUS mm

PART N

UMBER

INSIDE

DIAMETE

R mm

MINIMUM

BEND RA

DIUS mm

PART N

UMBER

INSIDE

DIAMETE

R mm

MINIMUM

BEND RA

DIUS mm

PAFS10 6.5 15

PAFS13 9.6 25

PAFS16 11.8 35

PAFS18 14.2 40

PACS20 14.3 40

PAFS21 16.5 45

– – –

PACS25 19.9 50

PAFS28 22.6 50

PACS28 21.7 50

PAFS34 28.8 60

PACS34 27.7 60

PACS42 35.2 65

PACS54 46.5 75

TYPE PASTANDARD WEIGHT

– – –

PAFM13 9.5 30

PAFM16 11.4 40

– – –

– – –

PAFM21 16.0 50

– – –

– – –

PAFM28 22.4 55

– – –

PAFM34 28.4 65

– – –

– – –

– – –

TYPE PAMEDIUM WEIGHT

TYPE PAHEAVY WEIGHT

– – –

PAFH13 9.0 35

PAFH16 11.3 45

– – –

– – –

– – –

PACH21 14.5 60

– – –

– – –

PACH28 21.3 70

– – –

PACH34 26.8 75

PACH42 34.6 90

PACH54 46.0 95

◆ Corrugated profile with fine pitch for increased cablecarrying capacity or coarse pitch for increased flexibilityTYPE PA Polyamide (Nylon) 6 in black or greyTYPE PR Modified Polyamide (Nylon) 6 in blackTYPE PI Modified Polyamide in black or greyTYPE PP Polypropylene in black

◆ Light, standard,medium & heavyweights available

FROM ADAPTAFLEX

Compatible with

LO

W

FIRE HAZ

AR

DLFH•LO

W

FIRE HAZAR

D•

LO

W

FIRE HAZ

AR

DLFH•LO

W

FIRE HAZAR

D•

LO

W

FIRE HAZ

AR

DLFH•LO

W

FIRE HAZAR

D•

Page 17: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

Accessories

15

10 10.0 FINE

13 13.0 FINE

16 15.8 FINE

18 18.5 FINE

20 20.0 COARSE

21 21.2 FINE

21 21.2 COARSE

25 25.0 COARSE

28 28.5 FINE

28 28.5 COARSE

34 34.5 FINE

34 34.5 COARSE

42 42.5 COARSE

54 54.5 COARSE

NOMINAL

CONDUIT S

IZE

OUTSIDE

DIAMETE

R mm

PITCH

PART N

UMBER

INSIDE

DIAMETE

R mm

MINIMUM

BEND RA

DIUS mm

PART N

UMBER

INSIDE

DIAMETE

R mm

MINIMUM

BEND RA

DIUS mm

PART N

UMBER

INSIDE

DIAMETE

R mm

MINIMUM

BEND RA

DIUS mm

– – –

PRFS13 9.4 25

PRFS16 11.7 35

– – –

– – –

PRFS21 16.6 45

– – –

– – –

– – –

PRCS28 21.7 50

– – –

PRCS34 27.7 60

PRCS42 35.1 65

PRCS54 46.6 75

TYPE PRSTANDARD WEIGHT

PI10 6.2 15

PI13 9.9 25

PI16 11.7 30

– – –

– – –

PI21 16.6 35

– – –

– – –

– – –

PI28 21.7 45

– – –

PI34 27.7 55

PI42 35.5 60

PI54 46.6 70

TYPE PISTANDARD WEIGHT

– – –

PPFM13 9.8 25

PPFM16 12.1 35

– – –

– – –

PPFM21 16.8 40

– – –

– – –

PPFM28 23.1 60

– – –

PPFM34 29.1 50

– – –

– – –

– – –

TYPE PPMEDIUM WEIGHT

TYPE ACCONDUIT CLIPPA (Nylon) 66 construction withintegral lid

ACB10 ACG10

ACB13 ACG13

ACB16 ACG16

– –

– –

ACB21 ACG21

ACB21 ACG21

– –

ACB28 ACG28

ACB28 ACG28

ACB34 ACG34

ACB34 ACG34

ACB42 ACG42

ACB54 ACG54

PART N

UMBER

(BLACK

)PAR

T NUMBER

(GREY)

Type PA conduits offer a range of pitches and weights enabling users to strike the correctbalance of mechanical strength and flexibility to suit most applications.

In addition, the flame retardant, low smoke density and toxicity properties of Halogen-free, low fire hazard (LFH) Type PA conduit complement the fire performance cableincreasingly being specified where public safety or the integrity of electronic equipmentare of concern.

More stringent Fire performance approvals, i.e. for Railway rolling stock or undergroundareas are met by enhanced low fire hazard (ELFH) Type PR conduit.

Robotic, rapid or continuous motion applications demanding high fatigue life and extraflexibility are covered by:

Type PI conduit, which is also used in low temperature environments.

Type PP conduit combined with Adaptalok Type PPA fittings provides a highly acid resistant,flexible system.

Approvals may be limited to certain products, see approvals on page 40.

BS EN 50086

LO

W

FI R E H A

ZA

RDELFH•

E

NHANCE

D•

● See pages 34 - 41 for Technical Details

● See pages 31 - 33 for Cutting Tools and Accessories

● Minimum bend radius is minimum inside bend radius in static mode

Page 18: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

ADAPTALOK SYSTEMSTRAIGHT ONE-PIECE PUSH-ON IP66 FITTINGS

TYPE A IP66STRAIGHT FITTING – FIXED EXTERNAL THREADfor insertion into threaded entries & knockouts

10 – – PG7 AL10/PG7/A

10 – – PG9 AL10/PG9/A

13 M16 AL13/M16/A PG9 AL13/PG9/A

13 – – PG11 AL13/PG11/A

13 – – PG13.5 AL13/PG13/A

16 M16 AL16/M16/A PG9 AL16/PG9/A

16 M20 AL16/M20/A PG11 AL16/PG11/A

16 – – PG13.5 AL16/PG13/A

16 – – PG16 AL16/PG16/A

18 – – PG13.5 AL18/PG13/A

20 M20 AL20/M20/A – –

21 M20 AL21/M20/A PG11 AL21/PG11/A

21 – – PG13.5 AL21/PG13/A

21 – – PG16 AL21/PG16/A

25 M25 AL25/M25/A – –

28 M25 AL28/M25/A PG21 AL28/PG21/A

34 M32 AL34/M32/A PG29 AL34/PG29/A

42 M40 AL42/M40/A PG36 AL42/PG36/A

54 M50 AL54/M50/A PG48 AL54/PG48/A

METRIC

THREAD

NOMINAL

CONDUIT S

IZE

PGTHREA

DPAR

T

NUMBER**

PART

NUMBER

10 1/4 AL10/PF025/A – –

13 3/8 AL13/PF038/A 3/8 AL13/038/A

16 3/8 AL16/PF038/A 3/8 AL16/038/A

16 1/2 AL16/PF050/A 1/2 AL16/050/A

21 1/2 AL21/PF050/A 1/2 AL21/050/A

28 3/4 AL28/PF075/A 3/4 AL28/075/A

34 1 AL34/PF100/A 1 AL34/100/A

42 11/4 AL42/PF125/A 11/4 AL42/125/A

54 11/2 AL54/PF150/A 11/2 AL54/150/A

54 2 AL54/PF200/A – –

PFTHREA

DNOMINAL

CONDUIT S

IZE

NPTTHREA

DPAR

T

NUMBER PART

NUMBER

TYPE PPA IP66STRAIGHT FITTING – FIXED EXTERNAL THREADfor insertion into threaded entries & knockouts

– –

– –

M16 AL13/M16/PPA

– –

– –

M16 AL16/M16/PPA

– –

– –

– –

– –

– –

M20 AL21/M20/PPA

– –

– –

– –

M25 AL28/M25/PPA

M32 AL34/M32/PPA

– –

– –

METRIC

THREAD

PART

NUMBER**

PUSH-IN PA66BLACK ONLYInserts into a 20mm diameter hole, panelthickness up to 4mm, no locknut required

16 AL16/KM20/A

21 AL21/KM20/A

NORMAL

CONDUIT S

IZE

PART

NUMBER

◆ Compatible with fine andcoarse pitch corrugatedflexible conduit systems

◆ Integral selflocking clips

◆ Internal taper providesIP66 seal

◆ Unrestricted through bore

◆ Fixed polyamide orswivel brass threadsfor easy installation

◆ TYPE A Polyamide (Nylon) 66 construction inblack or greyTYPE PPA Polypropylene construction in blackTYPE SA/SFA Polyamide (Nylon) 66 bodyin black or grey with nickel plated brass thread

Adaptalok fittings’ simple push and twist mounting ensures highmechanical strength and IP66 assembly with Type PA/PR/PI/PPconduits, whilst unauthorised or accidental removal is prevented bythe necessity to use a screwdriver or tool.

Adaptalok fittings complement LFH Type PA & PR conduits forassured fire performance with Nylon versions constructed from thePA66 grade giving added mechanical strength over PA6 fittings.

Type PPA fittings combine with conduit Type PP to provide a highlyacid resistant, flexible system.

Adaptalok fittings are available in 2 basic forms, namely fixedthreaded fittings in a wide range of thread forms or those comprisinga polyamide (Nylon) body with an integrated nickel plated brassthread or coupling.

The latter type incorporate an inherent swivel feature allowing elbowversions (pages 18 - 19) to be positioned easily reducing thepossibility of damage due to sideways movement of the conduit.

Swivel Adaptalok fittings can be MADE TO ORDER – MTO – tomeet a particular specification of thread or coupling.

01675

468202

ADAPTAFLEX-IN

FOL

INE

**supplied with locknut **supplied with locknut

16

Page 19: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

17

TYPE SA IP66STRAIGHT BODY – SWIVEL EXTERNAL THREADfor insertion into threaded entries & knockouts

TYPE SFA IP66STRAIGHT BODY – SWIVEL INTERNAL THREADfor attachment to external threads & other fittings

10

10

13

13

13

16

16

16

16

18

20

21

21

21

25

28

34

42

NOMINAL

CONDUIT S

IZE

– – – –

– – – –

M16 AL13/M16/A/ PG9 AL13/PG9/A/

– – PG11 MTO– – PG13.5 MTO

M16 AL16/M16/A/ PG9 MTO– – PG11 AL16/PG11/A/

– – PG13.5 MTO– – PG16 MTO– – – –

– – – –

M20 AL21/M20/A/ PG11 MTO– – PG13.5 AL21/PG13/A/

– – PG16 AL21/PG16/A/

– – – –

M25 AL28/M25/A/ PG21 AL28/PG21/A/

M32 AL34/M32/A/ PG29 AL34/PG29/A/

M40 AL42/M40/A/ PG36 AL42/PG36/A/

METRIC

THREAD

PGTHREA

DPAR

T

NUMBER PART

NUMBER

TYPE SBCA IP66STRAIGHT SCREEN CABLE FITTING – SWIVEL EXTERNAL THREADfor insertion into threaded entries & knockouts

– – – –

– – – –

M16 AL13/M16/A/ PG9 AL13/PG9/A/

– – PG11 MTO– – PG13.5 MTO

M16 AL16/M16/A/ PG9 MTO– – PG11 AL16/PG11/A/

– – PG13.5 MTO– – PG16 MTO– – – –

– – – –

M20 AL21/M20/A/ PG11 MTO– – PG13.5 AL21/PG13/A/

– – PG16 AL21/PG16/A/

– – – –

M25 AL28/M25/A/ PG21 AL28/PG21/A/

M32 AL34/M32/A/ PG29 AL34/PG29/A/

M40 AL42/M40/A/ PG36 AL42/PG36/A/

METRIC

THREAD

PGTHREA

DPAR

T

NUMBER PART

NUMBER

– – – –

– – – –

– – – –

– – – –

– – – –

– – – –

– – – –

– – – –

– – – –

– – – –

– – – –

M20 MTO PG11 MTO– – PG13.5 MTO– – PG16 AL21/PG16/A/

– – – –

M25 MTO PG21 AL28/PG21/A/

M32 MTO PG29 AL34/PG29/A/

M40 MTO PG36 AL42/PG36/A/

METRIC

THREAD

PGTHREA

DPAR

T

NUMBER PART

NUMBER

TYPE SBCAFerrule secures internal ◆cable screening

TYPE SBCAPolyamide (Nylon) 66 ◆body in black

◆ TYPE SBCANickel plated brassbraided screen cable fitting

◆ Compatible with fine andcoarse pitch corrugatedflexible conduit systems

● See pages 34 - 41 for technical details● For accessories see pages 32-33● MTO indicates MADE TO ORDER. Phone the ADAPTAFLEX

INFOLINE below for minimum order quantities & availability

Approvals may be limited to certain products, see approvals on page 40.

For black:Add 006510 to part no. eg AL13/M16/A/006510

For grey:Add 016510 to part no. eg AL13/M16/A/016510

For black:Add 006520 to part no. eg AL13/M16/A/006520

For grey:Add 016520 to part no. eg AL13/M16/A/016520

For black:Add 006514 to part no. eg AL21/PG16/A/006514

For grey:Add 016514 to part no. eg AL21/PG16/A/016514

FROM ADAPTAFLEX

BS EN 50086

Page 20: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

18

ADAPTALOK SYSTEM90° & 45° ONE-PIECE PUSH-ON IP66 FITTINGS

TYPE C90 IP6690° CURVED ELBOW – FIXED EXTERNAL THREADfor insertion into knockouts using a locknut

TYPE CS90 IP6690° CURVED ELBOW – SWIVEL EXTERNAL THREADfor insertion into threaded entries & knockouts

TYPE CSF90 IP6690° CURVED ELBOW – SWIVEL INTERNAL THREADfor attachment to external threads & other fittings

10 – – PG7 AL10/PG7/C90

13 M16 AL13/M16/C90 PG9 AL13/PG9/C90

13 – – – –

13 – – – –

16 M16 AL16/M16/C90 PG9 AL16/PG9/C90

16 M20 AL16/M20/C90 PG11 AL16/PG11/C90

16 – – PG13.5 AL16/PG13/C90

16 – – – –

21 M20 AL21/M20/C90 – –

21 – – PG13.5 AL21/PG13/C90

21 – – PG16 AL21/PG16/C90

28 M25 AL28/M25/C90 PG21 AL28/PG21/C90

34 M32 AL34/M32/C90 PG29 AL34/PG29/C90

42 M40 AL42/M40/C90 PG36 AL42/PG36/C90

54 M50 AL54/M50/C90 PG48 AL54/PG48/C90

METRIC

THREAD

NOMINAL

CONDUIT S

IZE

PGTHREA

DPAR

T

NUMBER**

PART

NUMBER

13 3/8 AL13/PF038/C90 3/8 AL13/038/C90

16 3/8 AL16/PF038/C90 3/8 AL16/038/C90

16 1/2 AL16/PF050/C90 1/2 AL16/050/C90

21 1/2 AL21/PF050/C90 1/2 AL21/050/C90

28 3/4 AL28/PF075/C90 3/4 AL28/075/C90

34 1 AL34/PF100/C90 1 AL34/100/C90

42 11/4 AL42/PF125/C90 11/4 AL42/125/C90

54 11/2 AL54/PF150/C90 11/2 AL54/150/C90

54 2 AL54/PF200/C90 – –

PFTHREA

DNOMINAL

CONDUIT S

IZE

NPTTHREA

DPAR

T

NUMBER PART

NUMBER

– – – –

M16 AL13/M16/C90/ PG9 AL13/PG9/C90/

– – PG11 MTO

– – PG13.5 MTO

M16 AL16/M16/C90/ PG9 MTO

– – PG11 AL16/PG11/C90/

– – PG13.5 MTO

– – PG16 MTO

M20 AL21/M20/C90/ PG11 MTO

– – PG13.5 AL21/PG13/C90/

– – PG16 AL21/PG16/C90/

M25 AL28/M25/C90/ PG21 AL28/PG21/C90/

M32 AL34/M32/C90/ PG29 AL34/PG29/C90/

M40 AL42/M40/C90/ PG36 AL42/PG36/C90/

– – – –

METRIC

THREAD

PGTHREA

DPAR

T

NUMBER PART

NUMBER

– – – –

M16 AL13/M16/C90/ PG9 AL13/PG9/C90/

– – PG11 MTO

– – PG13.5 MTO

M16 AL16/M16/C90/ PG9 MTO

– – PG11 AL16/PG11/C90/

– – PG13.5 MTO

– – PG16 MTO

M20 AL21/M20/C90/ PG11 MTO

– – PG13.5 AL21/PG13/C90/

– – PG16 AL21/PG16/C90/

M25 AL28/M25/C90/ PG21 AL28/PG21/C90/

M32 AL34/M32/C90/ PG29 AL34/PG29/C90/

M40 AL42/M40/C90/ PG36 AL42/PG36/C90/

– – – –

METRIC

THREAD

PGTHREA

DPAR

T

NUMBER PART

NUMBER

AL21/FL/C90

AL28/FL/C90

AL34/FL/90

AL42/FL/90

AL54/FL/90

PART

NUMBER

TYPE FLC90 IP6690°CURVED ELBOW – PANEL MOUNT FLANGEfor panel mounting via 2 or 4 hole fixing & integral face seal. Black & grey

**supplied with locknut For black:Add 006510 to part no. eg AL13/M16/C90/006510

For grey:Add 016510 to part no. eg AL13/M16/C90/016510

For black:Add 006520 to part no. eg AL13/M16/C90/006520

For grey:Add 016520 to part no. eg AL13/M16/C90/016520

NOTCURVED ORSWIVELSTYLE

TYPE FL /- IP66PANEL MOUNTING SWIVEL FLANGE, WITH INTEGRAL FACE SEAL for straight (A) and 45° elbows, available in black & grey

NOMINAL

CONDUIT S

IZE (m

m)

PART N

O.

TYPE F

L/APAR

T NO.

TYPE F

L/45

21 AL21/FL/A AL21/FL/45

28 AL28/FL/A AL28/FL/45

● MTO indicates MADE TO ORDER, contact Adaptaflexfor minimum order quantities and availability

AL34/FL/90

AL42/FL/90

AL54/FL/90

PART

NUMBER

TYPE FL90 IP6690° ELBOW BODY – PANEL MOUNT FLANGEfor panel mounting via 4 hole fixing & integral face seal

01675

468202

ADAPTAFLEX-IN

FOL

INE

Page 21: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

19

FROM ADAPTAFLEX

BS EN 50086

TYPE 45 Polyamide (Nylon) 66construction in black or greyTYPE S45/SF45 Polyamide (Nylon) 66 body in black or greywith nickel plated brass thread

Fixed Polyamide or ◆swivel brass threads for

easy installation

◆ Compatible with fine &coarse pitch corrugatedflexible conduit systems

Approvals may be limited to certain products, see approvals on page 40.

● See pages 34 - 41 for Technical Details

● See pages 31 - 33 for Cutting Tools and Accessories

TYPE S45 IP6645° ELBOW BODY – SWIVEL EXTERNAL THREADfor insertion into threaded entries & knockouts

TYPE SF45 IP6645° ELBOW BODY – SWIVEL INTERNAL THREADfor attachment to external threads & other fittings

TYPE 45 IP6645° ELBOW FITTING – FIXED EXTERNAL THREADfor insertion into knockouts using a locknut

M16 AL13/M16/45/ PG9 AL13/PG9/45/

– – PG11 MTO– – PG13.5 MTO– – – –

M16 AL16/M16/45/ PG9 MTO– – PG11 AL16/PG11/45/

– – PG13.5 MTO– – PG16 MTO

M20 AL21/M20/45/ PG11 MTO– – PG13.5 AL21/PG13/45/

– – PG16 AL21/PG16/45/

M25 AL28/M25/45/ PG21 AL28/PG21/45/

M32 AL34/M32/45/ PG29 AL34/PG29/45/

M40 AL42/M40/45/ PG36 AL42/PG36/45/

– – – –

METRIC

THREAD

PGTHREA

DPAR

T

NUMBER PART

NUMBER

M16 AL13/M16/45/ PG9 AL13/PG9/45/

– – PG11 MTO– – PG13.5 MTO– – – –

M16 AL16/M16/45/ PG9 MTO– – PG11 AL16/M16/45/

– – PG13.5 MTO– – PG16 MTO

M20 AL21/M20/45/ PG11 MTO– – PG13.5 AL21/PG13/45/

– – PG16 AL21/PG16/45/

M25 AL28/M25/45/ PG21 AL28/PG21/45/

M32 AL34/M32/45/ PG29 AL34/PG29/45/

M40 AL42/M40/45/ PG36 AL42/PG36/45/

– – – –

METRIC

THREAD

PGTHREA

DPAR

T

NUMBER PART

NUMBER

PFTHREA

DNPT

THREAD

PART

NUMBER PART

NUMBER

M16 AL13/M16/45 PG9 AL13/PG9/45

– – – –

– – – –

M16 AL16/M16/45 PG11 AL16/PG11/45

M20 AL16/M20/45 PG13.5 AL16/PG13/45

– – – –

– – – –

– – – –

M20 AL21/M20/45 – –

– – PG13.5 AL21/PG13/45

– – PG16 AL21/PG16/45

M25 AL28/M25/45 PG21 AL28/PG21/45

M32 AL34/M32/45 PG29 AL34/PG29/45

M40 AL42/M40/45 PG36 AL42/PG36/45

M50 AL54/M50/45 PG48 AL54/PG48/45

– – – –

– – – –

– – – –1/2 AL21/PF050/45 1/2 AL21/050/453/4 AL28/PF075/45 3/4 AL28/075/45

1 AL34/PF100/45 1 AL34/100/45

11/4 AL42/PF125/45 11/4 AL42/125/45

11/2 AL54/PF150/45 11/2 AL54/150/45

2 AL54/PF200/45 – –

METRIC

THREAD

PGTHREA

DPAR

T

NUMBER**

PART

NUMBER

13

13

13

16

16

16

16

16

21

21

21

28

34

42

54

NOMINAL

CONDUIT S

IZE

13

16

16

21

28

34

42

54

54

NOMINAL

CONDUIT S

IZE

For black:Add 006510 to part no. eg AL21/M20/45/006510

For grey:Add 016510 to part no. eg AL21/M20/45/016510

For black:Add 006520 to part no. eg AL21/M20/45/006520

For grey:Add 016520 to part no. eg AL21/M20/45/016520

**supplied with locknut

Page 22: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

20

ADAPTALOKUNEF CIRCULARCONNECTOR FITTINGS

NOMINAL

CONDUIT S

IZE

CONNECT

OR

SHELL SI

ZECO

NNECTOR

UNEF THREA

D

PART

NUMBER PART

NUMBER PART

NUMBER

13 5/8”-24 10SL/12S

13 3/4”-20 14S

13 7/8”-20 16/16S

16 5/8”-24 10SL/12S

16 3/4”-20 14S

16 7/8”-20 16/16S

16 1”-20 18

16 13/16”-18 20/22S

21 3/4”-20 14S

21 7/8”-20 16/16S

21 1”-20 18

21 11/8”-18 20

21 13/16”-18 20/22

21 17/16”-18 24/28

28 1”-20 18

28 13/16”-18 20/22

28 17/16”-18 24/28

28 13/4”-18 32

28 2”-18 36

28 1”-20 18

34 13/16”-18 20/22

34 17/16”-18 24/28

34 13/4”-18 32

34 2”-18 36

42 13/4”-18 32

42 2”-18 36

AL13/U063/A/000620

AL13/U075/A/000620

AL13/U088/A/000620

AL16/U063/A/000620

AL16/U075/A/000620

AL16/U088/A/000620

AL16/U100/A/000620

AL16/U119/A/000620

AL21/U075/A/000620

AL21/U088/A/000620

AL21/U100/A/000620

AL21/U113/A/000620

AL21/U119/A/000620

AL21/U144/A/000620

AL28/U100/A/000620

AL28/U119/A/000620

AL28/U144/A/000620

AL28/U175/A/000620

AL28/U200/A/000620

AL34/U100/A/000620

AL34/U119/A/000620

AL34/U144/A/000620

AL34/U175/A/000620

AL34/U200/A/000620

AL42/U175/A/000620

AL42/U200/A/000620

AL13/U063/C90/000620

AL13/U075/C90/000620

AL13/U088/C90/000620

AL16/U063/C90/000620

AL16/U075/C90/000620

AL16/U088/C90/000620

AL16/U100/C90/000620

AL16/U119/C90/000620

AL21/U075/C90/000620

AL21/U088/C90/000620

AL21/U100/C90/000620

AL21/U113/C90/000620

AL21/U119/C90/000620

AL21/U144/C90/000620

AL28/U100/C90/000620

AL28/U119/C90/000620

AL28/U144/C90/000620

AL28/U175/C90/000620

AL28/U200/C90/000620

AL34/U100/C90/000620

AL34/U119/C90/000620

AL34/U144/C90/000620

AL34/U175/C90/000620

AL34/U200/C90/000620

AL42/U175/C90/000620

AL42/U200/C90/000620

AL13/U063/45/000620

AL13/U075/45/000620

AL13/U088/45/000620

AL16/U063/45/000620

AL16/U075/45/000620

AL16/U088/45/000620

AL16/U100/45/000620

AL16/U119/45/000620

AL21/U075/45/000620

AL21/U088/45/000620

AL21/U100/45/000620

AL21/U113/45/000620

AL21/U119/45/000620

AL21/U144/45/000620

AL28/U100/45/000620

AL28/U119/45/000620

AL28/U144/45/000620

AL28/U175/45/000620

AL28/U200/45/000620

AL34/U100/45/000620

AL34/U119/45/000620

AL34/U144/45/000620

AL34/U175/45/000620

AL34/U200/45/000620

AL42/U175/45/000620

AL42/U200/45/000620

Compatible with fine and◆ coarse pitch corrugated

flexible conduit systems

◆ Polyamide (Nylon) 66 body in black

◆ Internal O-ringseal connector

Note: Typically for use with connectors from- Litton- AB connectors- AMP- Burndy

Other sizes available on request.

◆ Thread swivels foreasy installation

01675

468202

ADAPTAFLEX-IN

FOL

INE

TYPE A IP66STRAIGHT BODY – SWIVEL INTERNAL THREADfor coupling to UNEF circularconnectors

TYPE C90 IP6690° ELBOW BODY – SWIVEL INTERNAL THREADfor coupling to UNEF circularconnectors

TYPE 45 IP6645° ELBOW BODY – SWIVEL INTERNAL THREADfor coupling to UNEF circularconnectors

Approvals may be limited to certain products, see approvals on page 40.

BS EN 50086

Page 23: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

21

ADAPTALOK COUPLERS

RIGID CONDUITCOUPLER IP66STRAIGHT PA66 BODY – SWIVEL BRASS COUPLERfor coupling to metallic rigid PG conduit

NOMINAL

CONDUIT S

IZE

PART

NUMBERRIGID

CONDUIT S

IZE

3-WAY COUPLER IP663-WAY PA66 FITTINGfor coupling to corrugated flexible conduit

PART

NUMBERNOMINAL

CONDUIT S

IZE

COMBIN

ATION

SWIVEL COUPLER IP66STRAIGHT PA66 BODY – SWIVEL COUPLERfor coupling to corrugated flexible conduit

PART

NUMBER

13 – –

16 – –

21 PG16 AL21/PG16/A/006530

28 PG21 AL28/PG21/A/006530

34 PG29 AL34/PG29/A/006530

42 PG36 AL42/PG36/A/006530

13X10X10 AL131010/Y

16X13X13 AL161313/Y

21X16X16 AL211616/Y

28X21X21 AL282121/Y

– –

– –

AL13/AL13/A/000040

AL16/AL16/A/000040

AL21/AL21/A/000040

AL28/AL28/A/000040

AL34/AL34/A/000040

AL42/AL42/A/000040

FROM ADAPTAFLEX

Approvals may be limited to certain products, see approvals on page 40.

Adaptalok fittings’ simple push and twist mountingensures high mechanical strength and IP66 assemblywith Type PA/PR/PI/PP conduits, whilst unauthorisedor accidental removal is prevented by the necessity touse a screwdriver or tool.

Lightweight aluminium or polyamide (Nylon) threadedswivel Adaptalok fittings (opposite page) providesimple coupling to UNEF threaded military style multi-pin connectors whilst Adaptalok couplers (this page)facilitate the connection of other conduits in variousarrangements.

BS EN 50086

● See pages 34 - 41 for Technical details

● See pages 32 - 33 for Accessories

Page 24: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

10 FINE

13 FINE

16 FINE

16 FINE

21 FINE

21 COARSE

28 FINE

28 COARSE

34 FINE

34 COARSE

42 COARSE

54 COARSE

NOMINAL

CONDUIT S

IZE

CONDUIT

PITCH

ASF34/FL/90

ASC34/FL/90

ASC42/FL/90

ASC54/FL/90

FittingsTYPE A IP67STRAIGHT FITTING – FIXED EXTERNAL THREADfor insertion into knockouts using a locknut

M16 ASF10/M16/A PG9 ASF10/PG9/A

M16 ASF13/M16/A PG9 ASF13/PG9/A

M16 ASF16/M16/A PG11 ASF16/PG11/A

M20 ASF16/M20/A PG13.5 ASF16/PG13/A

M20 ASF21/M20/A PG16 ASF21/PG16/A

M20 ASC21/M20/A PG16 ASC21/PG16/A

M25 ASF28/M25/A PG21 ASF28/PG21/A

M25 ASC28/M25/A PG21 ASC28/PG21/A

M32 ASF34/M32/A PG29 ASF34/PG29/A

M32 ASC34/M32/A PG29 ASC34/PG29/A

M40 ASC42/M40/A PG36 ASC42/PG36/A

M50 ASC54/M50/A PG48 ASC54/PG48/A

PART

NUMBER**

METRIC

THREAD

PART

NUMBERPGTHREA

D

TYPE FL90 IP6790° ELBOW FITTING – PANEL MOUNT FLANGEfor panel mounting via 4 holefixing & integral face seal

PART

NUMBER

22

ADAPTASEAL SYSTEMLIQUID TIGHT COMPRESSION FITTINGS

01675

468202

ADAPTAFLEX-IN

FOL

INE

◆ Compatible with fine andcoarse pitch corrugatedflexible conduit systems

◆ TYPE RKReducing Kit in black combines differentsize conduit and fittings

◆ TYPE TPolyamide (Nylon) 66 T-piece in blackwith removable inspection cover

◆ TYPE AWBPrevents fitting loosening invibrating applications

◆ Polyamide (Nylon) 66construction in black or grey

◆ Face seal

◆ Liquid tight seal

**supplied with locknut

TYPE C90 IP6790° CURVED ELBOW – FIXED EXTERNAL THREADfor insertion into knockouts using a locknut

PART

NUMBER**

METRIC

THREAD

PART

NUMBERPGTHREA

D

M16 ASF10/M16/C90 PG9 ASF10/PG9/C90

M16 ASF13/M16/C90 PG9 ASF13/PG9/C90

M16 ASF16/M16/C90 PG11 ASF16/PG11/C90

M20 ASF16/M20/C90 PG13.5 ASF16/PG13/C90

M20 ASF21/M20/C90 PG16 ASF21/PG16/C90

M20 ASC21/M20/C90 PG16 ASC21/PG16/C90

M25 ASF28/M25/C90 PG21 ASF28/PG21/C90

M25 ASC28/M25/C90 PG21 ASC28/PG21/C90

M32 ASF34/M32/C90 PG29 ASF34/PG29/C90

M32 ASC34/M32/C90 PG29 ASC34/PG29/C90

M40 ASC42/M40/C90 PG36 ASC42/PG36/C90

M50 ASC54/M50/C90 PG48 ASC54/PG48/C90

**supplied with locknut

Page 25: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

FROM ADAPTAFLEX

Accessories

AWB13

AWB13

AWB16

AWB16

AWB21

AWB21

AWB28

AWB28

AWB34

AWB34

TYPE AWBANTI-VIBRATION WASHERacetal washer prevents fittingloosening under vibration

PART

NUMBER

23

10 ASF10X3/T

13 ASF13X3/T

16 ASF16X3/T

16 ASF16X3/T

21 ASF21X3/T

21 ASC21X3/T

28 ASF28X3/T

28 ASC28X3/T

34 ASF34X3/T

34 ASC34X3/T

– –

– –

TYPE T IP67INSPECTION T-PIECEfor connection to corrugated flexible conduit

PART

NUMBERFOR CONNECT

ION

TO NOMINAL

CONDUIT S

IZE

– – – – –

RK13-10 – – – –

– RK16-13 – – –

– RK16-13 – – –

– RK21-13 RK21-16 – –

– RK21-13 RK21-16 – –

– RK28-13 RK28-16 RK28-21 –

– RK28-13 RK28-16 RK28-21 –

– – – RK34-21 RK34-28

– – – RK34-21 RK34-28

– – – – –

– – – – –

TYPE RK IP67REDUCING KITfor connection to a reduced conduit size

REDUCIN

G TO

CONDUIT S

IZE 10

REDUCIN

G TO

CONDUIT S

IZE 13

REDUCIN

G TO

CONDUIT S

IZE 16

REDUCIN

G TO

CONDUIT S

IZE 21

REDUCIN

G TO

CONDUIT S

IZE 28

Adaptaseal compression fittings are widely used with TypePA/PR/PI conduits, e.g. in external applications requiringassured IP67 weatherproofing, flexibility and highmechanical strength.

In addition, Adaptaseal fittings complement LFH Type PA &PR conduits for assured Fire performance where Public safetyor the integrity of electronic equipment are of concern.

Old PF/PC part no‘s are now replaced by AS.

Approvals may be limited to certain products, see approvals on page 40.

BS EN 50086

● See pages 34 - 41 for Technical details

● See pages 32 - 33 for Accessories

Page 26: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

16

16

21

28

34

NOMINAL

CONDUIT S

IZE

FittingsTYPE A IP40STRAIGHT ROTATIONAL FITTING – EXTERNAL THREADfor insertion into threaded entries & knockouts

M16 AR16/M16/A PG11 AR16/PG11/A

M20 AR16/M20/A PG13.5 AR16/PG13/A

M20 AR21/M20/A PG16 AR21/PG16/A

M25 AR28/M25/A PG21 AR28/PG21/A

M32 AR34/M32/A PG29 AR34/PG29/A

PART

NUMBER*

METRIC

THREAD

PART

NUMBERPGTHREA

D

24

ADAPTARING SYSTEMROTATIONAL IP40 COMPRESSION FITTINGS

01675

468202

ADAPTAFLEX-IN

FOL

INE

◆ Compatible with fine and coarse pitch corrugatedflexible conduit systems

◆ TYPE TPolyamide (Nylon) 66 T-piece in blackwith removable inspection cover

◆ TYPE AWBPrevents fitting loosening invibrating applications

◆ Polyamide (Nylon) 66construction in black or grey

◆ C ring allows fitting to actas rotating joint

* supplied with locknut

NOMINAL

CONDUIT S

IZE

TYPE C90 IP4090° CURVED ELBOW ROTATIONAL FITTING – EXTERNAL THREADfor insertion into threaded entries & knockouts

M16 AR16/M16/C90 PG11 AR16/PG11/C90

M20 AR16/M20/C90 PG13.5 AR16/PG13/C90

M20 AR21/M20/C90 PG16 AR21/PG16/C90

M25 AR28/M25/C90 PG21 AR28/PG21/C90

M32 AR34/M32/C90 PG29 AR34/PG29/C90

M40 AR42/M40/C90 PG31 AR42/PG31/C90

M50 AR54/M50/C90 PG48 AR54/PG48/C90

* supplied with locknut

PART

NUMBER*

METRIC

THREAD

PART

NUMBERPGTHREA

D

16

16

21

28

34

42

54

Page 27: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

AR34/FL/90

FROM ADAPTAFLEX

AccessoriesTYPE FL90 IP6790° ELBOW FITTING – PANEL MOUNT FLANGEfor panel mounting via 4 hole fixing & integral face seal

PART

NUMBER

AR16X3/T

AR16X3/T

AR21X3/T

AR28X3/T

AR34X3/T

PART

NUMBER

AWB16

AWB16

AWB21

AWB28

AWB34

TYPE AWBANTI-VIBRATION WASHER

PART

NUMBER

25

Adaptaring fittings may be combined with LFH Type PA & PRconduits for assured Fire performance in applications wherewater resistance is not required.

Ideally mounted onto Type PI conduit, the freely rotating C-ring incorporated in Adaptaring fittings avoids the risk ofconduit failure due to wear or fracture in constantly rotating ortwisting applications, e.g. in Robotics or CCTV mounting heads.

Approvals may be limited to certain products, see approvals on page 40.

TYPE T IP40ROTATIONAL INSPECTION T-PIECEfor connection to corrugated flexible conduit

● See pages 34 - 41 for Technical details

● See pages 32 - 33 for Accessories

Page 28: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

Conduit

26

01675

468202

ADAPTAFLEX-IN

FOL

INE

HI-SPEC NON-METALLIC FLEXIBLE SYSTEMSTYPE PK – SUPER LOW FIRE HAZARD, HIGH TEMPERATURETYPE PKTC – SUPER LOW FIRE HAZARD, HIGH TEMPERATURE, HIGH EMI SCREENTYPE PKSS – SUPER LOW FIRE HAZARD, HIGH TEMPERATURE, ABUSE RESISTANT,

STANDARD EMI SCREENTYPE PRTC – ENHANCED LOW FIRE HAZARD, HIGH EMI SCREENTYPE PRSS – ENHANCED LOW FIRE HAZARD, ABUSE RESISTANT, STANDARD EMI SCREEN

PKFS16

PKFS21

PKCS28

PKCS34

TYPE PKUNBRAIDED

TYPEPKTCTINNED COPPERBRAIDED

PART

NUMBER

PKFSTC16

PKFSTC21

PKCSTC28

PKCSTC34

PART

NUMBER

PKFSSS16

PKFSSS21

PKCSSS28

PKCSSS34

PART

NUMBER

TYPEPKSSSTAINLESS STEELBRAIDED

FINE 15.8 11.7 45

FINE 17.2 11.7 45

FINE 21.2 16.6 60

FINE 23.6 16.6 60

COARSE 28.5 21.7 65

COARSE 30.0 21.7 65

COARSE 34.5 27.7 80

COARSE 36.0 27.7 80

PITCH OUTSI

DE

DIAMETE

R mm

INSIDE

DIAMETE

R mm

M16 PK16/M16/A

– –

M20 PK21/M20/A

– –

M25 PK28/M25/A

– –

M32 PK34/M32/A

– –

METRIC

THREAD

PART

NUMBER

FittingsTYPE B IP67STRAIGHT FITTING –SWIVEL EXTERNAL THREADfor insertion into threaded entries & knockouts

– – – –

M16 PBF16/M16/B PG11 PBF16/PG11/B

– – – –

M20 PBF21/M20/B PG16 PBF21/PG16/B

– – – –

M25 PBC28/M25/B PG21 PBC28/PG21/B

– – – –

M32 PBC34/M32/B PG29 PBC34/PG29/B

PART

NUMBERMETRIC

THREAD

PART

NUMBERPGTHREA

D

TYPE PKHigh temperature ◆silicone seal

◆ CONDUITNon-metallic corrugated profile.TYPE PK/TYPE PKTC/TYPE PKSS Polyketone.TYPE PRTC/TYPE PRSS Modified Polyamide (Nylon) 6.

◆ FITTINGNickel platedbrass components

TYPE BThread swivels for ◆easy installation

◆ PROTECTIVE OVERBRAIDTYPE PRTC/TYPE PKTC Tinned copper.TYPE PRSS/TYPE PKSS Stainless steel.

EMI

S

CR

EE

N•

E

MI S C R EEN

•E

MI

SC

R

EEN•

HIGH

EMI

S

CR

EE

N•

E

MI S C R EEN

•E

MI

SC

R

EEN•

STANDARD

SU

PE

RLOW FIRE H

A

ZA

RDSLFH•

SU

PE

RLOW FIRE HA

ZA

RD

TYPE PK IP67STRAIGHT FITTING –FIXED EXTERNAL THREADfor insertion into knockoutsusing a locknut

MINIMUM BEND

RADIUS m

m

Page 29: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

Conduit

27

Super low fire hazard (SLFH) Type PK conduit offers superiormechanical protection and can also be used with Adaptalok,Adaptaseal or Adaptaring fittings. Alternatively, extremetemperature performance requires the use of Type PK fittings.

Overbraided SLFH Type PKTC conduit meets high EMI screenspecifications whilst Type PKSS conduit is overbraided toincrease the security of installations in sensitive or high riskPublic areas, e.g. in underground communications or lighting.

Overbraided enhanced low fire hazard (ELFH) Type PRTCadds high EMI screen to its Fire performance approval forRailway rolling stock or underground areas, whilst Type PRSSprovides increased abuse resistance in similar applications,e.g. station platform or CCTV installations.

TYPEPRTCTINNED COPPERBRAIDED

PRFSTC16

PRFSTC21

PRCSTC28

PRCSTC34

PRCSTC42

PART

NUMBER

TYPEPRSSSTAINLESS STEELBRAIDED

PRFSSS16

PRFSSS21

PRCSSS28

PRCSSS34

PRCSSS42

PART

NUMBER

FINE 17.2 11.7 35

FINE 23.6 16.6 45

COARSE 30.0 21.7 50

COARSE 36.0 27.7 60

COARSE 43.5 35.1 65

PITCH OUTSI

DE

DIAMETE

R mm

INSIDE

DIAMETE

R mm

MINIMUM BEND

RADIUS m

m

FittingsTYPE B IP67STRAIGHT FITTING – SWIVEL EXTERNAL THREADfor insertion into threaded entries & knockouts

M16 PBF16/M16/B PG11 PBF16/PG11/B

M20 PBF21/M20/B PG16 PBF21/PG16/B

M25 PBC28/M25/B PG21 PBC28/PG21/B

M32 PBC34/M32/B PG29 PBC34/PG29/B

M40 PBC42/M40/B PG36 PBC42/PG36/B

PART

NUMBERMETRIC

THREAD

PART

NUMBERPGTHREA

D

Approvals may be limited to certain products, see approvals on page 40.

BS EN 50086

EMI

S

CR

EE

N•

E

MI S C R EEN

•E

MI

SC

R

EEN•

HIGH

EMI

S

CR

EE

N•

E

MI S C R EEN

•E

MI

SC

R

EEN•

STANDARD

LO

W

FI R E H A

ZA

RDELFH•

E

NHANCE

D•

● See pages 34 - 41 for Technical details

● See page 5 for braided conduit P-Clip Support

● See page 15 for unbraided Corrugated Conduit Support

● See page 31 - 33 for accessories

Page 30: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

Conduit

28

01675

468202

ADAPTAFLEX-IN

FOL

INE

KORIFIT NON-METALLIC PLIABLE SYSTEMSTYPE KF – GENERAL PURPOSE PVCU FOR STATIC APPLICATIONS

MINIMUM

BEND RA

DIUS mm

12 13.0

16 16.0

16 16.0

20 20.0

25 25.0

32 34.5

40 42.5

50 54.5

NOMINAL

CONDUIT S

IZE

OUTSIDE

DIAMETE

R mm

TYPE KFLIGHT WEIGHT – GREY ONLY

– – –

KFL16 12.1 25

KFL16 12.1 25

KFL20 14.5 30

KFL25 19.9 40

KFL32 29.5 50

KFL40 36.3 65

KFL50 48.0 75

PART

NUMBER INSIDE

DIAMETE

R mm

MINIMUM

BEND RA

DIUS mm

TYPE KFSTANDARD WEIGHT – WHITE ONLY

– – –

KFS16 11.9 25

KFS16 11.9 25

KFS20 14.3 30

KFS25 19.7 40

– – –

– – –

– – –

PART

NUMBER INSIDE

DIAMETE

R mm

MINIMUM

BEND RA

DIUS mm

TYPE KFMEDIUM WEIGHT – BLACK ONLY

KFM12 9.5 20

KFM16 11.9 25

KFM16 11.9 25

KFM20 14.3 30

KFM25 19.7 40

KFM32 29.5 50

KFM40 36.1 65

KFM50 47.7 75

PART

NUMBER INSIDE

DIAMETE

R mm

◆ TYPE KF Polyamide (Nylon) 66 one-piece push-on fitting in whiteTYPE KC (not pictured) Polyamide (Nylon) 66 compressionfitting in black or grey (KC/A sizes16-25 available in white)

◆ CONDUITKF LIGHT WEIGHT PVCU in greyKF STANDARD WEIGHT PVCU in whiteKF MEDIUM WEIGHT PVCU in black

◆ COUPLERPolyamide (Nylon) 66 one-piece push-onconduit coupler in white

Page 31: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

FROM ADAPTAFLEX

29

Korifit PVCU pliable systems Type KF are particularly suitablefor wiring protection and routeing in static, light duty, industrialand commercial installations where regular flexing is notrequired, e.g. in workshop, laboratory or retail premises.

IP65 water resistant fittings should be used where equipmentis periodically cleaned, e.g. in kitchens or supermarkets.

White Korifit is often combined with white trunking or rigidconduit systems, e.g. in office cable management systems.

Old DPL & DPM part no‘s are now replaced by KFL & KFM.

FittingsTYPE KC/A IP40STRAIGHT FITTING – FIXED EXTERNAL THREADfor insertion into threaded entries & knockouts

M16 KC12/M16/A

M16 KC16/M16/A

M20 KC16/M20/A

M20 KC20/M20/A

M25 KC25/M25/A

M32 KC32/M32/A

M40 KC40/M40/A

M50 KC50/M50/A

PART

NUMBER**

METRIC

THREAD

TYPE KF/A IP65STRAIGHT FITTING –FIXED EXTERNAL THREADfor insertion into threaded entries & knockouts

– –

M16 KF16/M16/A

M20 KF16/M20/A

M20 KF20/M20/A

M25 KF25/M25/A

– –

– –

– –

PART

NUMBER**

METRIC

THREAD

COUPLER IP65STRAIGHT ONE PIECE COUPLERfor coupling to corrugated flexible conduit

KF2020

PART

NUMBER

Approvals may be limited to certain products, see approvals on page 40.

**supplied with locknut**supplied with locknut

BS EN 50086

● See pages 34 - 41 for Technical details

● See page 5 for conduit P-Clip Support

● See pages 31 - 33 for Cutting Tools & Accessories

● Minimum bend radius is minimum inside bend radius in static mode

TYPE KC/C90 IP4090° CURVED ELBOW FITTING – FIXED EXTERNAL THREADfor insertion into knockouts

M16 KC12/M16/C90

M16 KC16/M16/C90

M20 KC16/M20/C90

M20 KC20/M20/C90

M25 KC25/M25/C90

M32 KC32/M32/C90

M40 KC40/M40/C90

M50 KC50/M50/C90

**supplied with locknut

PART

NUMBER**

METRIC

THREAD

Page 32: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

XF12 14.5 10.0 25

XF16 16.5 12.0 30

XF16 16.5 12.0 30

XF20 20.5 16.0 35

XF25 27.5 22.0 50

XF32 33.5 28.0 60

XF40 44.0 38.0 80

XF50 57.5 50.0 105

PART

NUMBER OUTSIDE

DIAMETE

R mm

INSIDE

DIAMETE

R mm

MINIMUM

BEND RA

DIUS mm

Conduit

30

01675

468202

ADAPTAFLEX-IN

FOL

INE

XTRAFLEX NON-METALLIC FLEXIBLE SYSTEMTYPE XF – GENERAL PURPOSE, TORSIONAL CAPABILITY, PVC

FittingsTYPE A IP65STRAIGHT FITTING – FIXED EXTERNAL THREADfor insertion into threaded entries & knockouts

TYPE XF

M16 XF12/M16/D PG9 XF12/PG9/D

M16 XF16/M16/D PG11 XF16/PG11/D

M20 XF16/M20/D PG13.5 XF16/PG13/D

M20 XF20/M20/D PG16 XF20/PG16/D

M25 XF25/M25/D PG21 XF25/PG21/D

M32 XF32/M32/D PG29 XF32/PG29/D

M40 XF40/M40/D PG36 XF40/PG36/D

M50 XF50/M50/D PG48 XF50/PG48/D

**supplied with locknut

PART

NUMBER**

METRIC

THREAD

PART

NUMBERPGTHREA

D

◆ FITTINGPolyamide (Nylon) 66compression type in black

◆ CONDUITHelical profile smooth boreunplasticised PVC spiral withplasticised PVC covering

◆ Liquid resistant seal

◆ Face seal

Approvals may be limited to certain products, see approvals on page 40.

● See pages 34 - 41 for Technical details

● See page 5 for conduit P-Clip Support.

● See pages 31 - 33 for Cutting Tools & Accessories

● Minimum bend radius is minimum inside bend radius in static mode

The Xtraflex PVC system is ideally suitable withinapplications where twisting or torsional forces arelikely to be applied to the conduit. The nature ofits construction also allows it to bend to a verytight radius.

Type A or type 90 fittings will maintain an IP65rating against ingress of solids and liquids.

TYPE C90 IP6590° CURVED ELBOW FITTING – FIXED EXTERNAL THREADfor insertion into knockouts

M16 XF12/M16/C90 PG9 XF12/PG9/C90

M16 XF16/M16/C90 PG11 XF16/PG11/C90

M20 XF16/M20/C90 PG13.5 XF16/PG13/C90

M20 XF20/M20/C90 PG16 XF20/PG16/C90

M25 XF25/M25/C90 PG21 XF25/PG21/C90

M32 XF32/M32/C90 PG29 XF32/PG29/C90

M40 XF40/M40/C90 PG36 XF40/PG36/C90

M50 XF50/M50/C90 PG48 XF50/PG48/C90

**supplied with locknut

PART

NUMBER**

METRIC

THREAD

PART

NUMBERPGTHREA

D

Page 33: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

31

CONDUIT CUTTING TOOLSKWIKCUTSWINGCUTROTOCUTCUT-VICE

ToolsKWIKCUT

Kwikcut is the ideal cutting tool for non-metallic conduits (PA, PR, PI, PP,KFL, KFS, KFM & XF) up to 32mm.

CONSTRUCTIONKwikcut comprises a Teflon coated tool-steel blade supported in a toughnylon handle.

CUTTING INSTRUCTIONSPlace the conduit between the cutting blade and lower support, squeeze thehandles and rotate the conduit for a clean, easy cut.Spare blades are available.

SWINGCUT

Swingcut is a versatile vice and saw combination tool which facilitates aneat, square cut for liquid tight and pliable conduits between 10mm and32mm. Six to one leverage advantage provides a strong cutting action.

CONSTRUCTIONMade from diecast and hardened steel, the Swingcut comprises a clamp,saw blade (at right angles to the clamp) and operating handle.

CUTTING INSTRUCTIONSPlace the conduit in the vice and secure. Move the operating handlebackwards and forwards whilst applying increasing pressure to thesupporting handle.Hardened captive spring loaded retaining pins make blade replacement easy.Spare blades are available.

ROTOCUT

Rotocut offers a simple but effective method for cutting 20mm and 25mmS, SS, SP, LFH-SP and SN conduit types.

CONSTRUCTIONIts rugged diecast body incorporates a recessed guide, clamping pin,squeeze lever, blade and cutting handle.

CUTTING INSTRUCTIONSAdjust the clamping pin so that the conduit is just held in the recess.Squeeze the lever and body whilst rotating the cutting blade. When theblade appears on the inside of the conduit, release the pressure andremove the conduit. A simple twist will then separate the two parts. Wherethe conduit is covered, the covering can be cut prior to separation.Spare blades are available.

CUT-VICE

Cut-vice offers the ability to produce a clean cut for conduit sizes 16mm to40mm.

CONSTRUCTIONIts rugged diecast body incorporates an integral handle and conduit guide.An adjustable clamp secures the conduit to the body.

CUTTING INSTRUCTIONSPlace the conduit along the vice body and tighten the clamp. Holding theconduit and integral handle together, insert a hacksaw blade into the guideand cut. For braided conduit, wrap adhesive tape around the cutting point to securebraid. Remove tape after cutting.

Page 34: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

32

ACCESSORIESMETALLIC AND NON-METALLIC LOCKNUTS SEALING WASHERSMETALLIC THREAD ENLARGERS, REDUCERS & CONVERTERS WITH ONE EXTERNAL & ONE INTERNAL THREADMETALLIC PROXIMITY SWITCH CONNECTORSUNEF CONVERTERS WITH TWO INTERNAL THREADS

METALLIC & NON-METALLIC LOCKNUTS

SEALINGWASHERS

THREAD

NICKEL

PLATED

BRASS

GALVAN

ISED

STEEL PA

(NYLON)

BLACK PA

(NYLON)

GREY

M10

M16

M20

M25

M32

M40

M50

M63

M75

PG7

PG9

PG11

PG13.5

PG16

PG21

PG29

PG36

PG42

PG48

LNB/M10 – – –

LNB/M16 LNS/M16 LNPB/M16 LNPG/M16

LNB/M20 LNS/M20 LNPB/M20 LNPG/M20

LNB/M25 LNS/M25 LNPB/M25 LNPG/M25

LNB/M32 LNS/M32 LNPB/M32 LNPG/M32

LNB/M40 – LNPB/M40 LNPG/M40

LNB/M50 – LNPB/M50 LNPG/M50

LNB/M63 – LNPB/M63 LNPG/M63

LNB/M75 – – –

LNB/PG7 – LNPB/PG7 LNPG/PG7

LNB/PG9 – LNPB/PG9 LNPG/PG9

LNB/PG11 – LNPB/PG11 LNPG/PG11

LNB/PG13 – LNPB/PG13 LNPG/PG13

LNB/PG16 – LNPB/PG16 LNPG/PG16

LNB/PG21 – LNPB/PG21 LNPG/PG21

LNB/PG29 – LNPB/PG29 LNPG/PG29

LNB/PG36 – LNPB/PG36 LNPG/PG36

LNB/PG42 – LNPB/PG42 LNPG/PG42

LNB/PG48 – LNPB/PG48 LNPG/PG48

TO FIT

THREAD

NEOPRENE

FACE S

EALING

M10 –

M16 SWM16

M20 SWM20

M25 SWM25

M32 SWM32

M40 SWM40

M50 SWM50

M63 –

M75 –

PG7 SWPG07

PG9 SWPG09

PG11 SWPG11

PG13.5 SWPG13

PG16 SWPG16

PG21 SWPG21

PG29 SWPG29

PG36 SWPG36

PG42 SWPG42

PG48 SWPG48

METALLIC PROXIMITY SWITCH CONNECTORS & UNEF THREAD CONVERTERS WITH TWO INTERNAL THREADS(other sizes can be made to order, phone the Adaptaflex Infoline)

INTERNAL

THREAD

M12

M18

M303/8"UNEF3/4"UNEF7/8"UNEF

1"UNEF

13/16"UNEF

17/16"UNEF

M16 M20 M25 M32 PG9

PSA16/M12 – – – PSA9/M12

PSA16/M18 – – – PSA9/M18

PSA16/M30 – – – PSA9/M30

B/U063-M16/TC – – – –

B/075U-M16/TC B/075U-M20/TC – – –

– B/088U-M20/TC – – –

– B/100U-M20/TC B/100U-M25/TC – –

– B/119U-M20/TC B/119U-M25/TC – –

– – B/144U-M25/TC B/144U-M32/TC –

ACCESSORIES NOTES:● See page 5 for P-Clip Conduit Support

● See page 15 for Conduit Clip with Integral Lid

01675

468202

ADAPTAFLEX-IN

FOL

INE

TO INTERNAL THREAD

M16 PG9 B/PG9/90 –

M16 PG11 B/PG11/90 B/PG11/45

M20 PG13.5 B/PG13/90 B/PG13/45

M20 PG16 B/PG16/90 B/PG16/45

M25 PG21 B/PG21/90 B/PG21/45

90°ELB

OW

PART N

UMBER

45°ELB

OW

PART N

UMBER

METRIC

INTERNAL

THREAD

PG EXT

ERNAL

THREAD

90° & 45° BRASS ELBOWS

M20 1/2" B/050/90 B/050/45

M25 3/4" B/075/90 B/075/45

M32 1" B/100/90 –

90°ELB

OW

PART N

UMBER

45°ELB

OW

PART N

UMBER

METRIC

INTERNAL

THREAD

NPT

EXTERN

AL THREA

D

For metric external threaded versions see page 9.

Page 35: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

33

EXTERN

AL

THREAD

M16

M20

M25

M32

M40

PG7

PG9

PG11

PG13.5

PG16

PG21

PG29

PG36

PG42

PG481/2"NPT

METALLIC ENLARGERS, REDUCERS & CONVERTERS WITH ONE EXTERNAL & ONE INTERNAL THREAD(other sizes can be made to order, phone the Adaptaflex Infoline)

B/M16-M10/R – B/M16-M20/E – – –

B/M20-M10/R B/M20-M6/R – B/M20-M25/E – –

– – B/M25-M20/R – B/M25-M32/E –

– – – B/M32-M25/R – –

– – – – B/M40-M32/R –

– B/PG7-M16/TC – – – –

– B/PG9-M16/TC B/PG9-M20/TC – – –

– B/PG11-M16/TC B/PG11-M20/TC – – –

– B/PG13-M16/TC B/PG13-M20/TC – – –

– B/PG16-M16/TC B/PG16-M20/TC B/PG16-M25/TC – –

– – B/PG21-M20/TC B/PG21-M25/TC B/PG21-M32/TC –

– – B/PG29-M20/TC B/PG29-M25/TC B/PG29-M32/TC –

– – – – B/PG36-M32/TC –

– – – – – –

– – – – – –

– B/050-M16/TC B/050-M20/TC – – –

EXTERN

AL

THREAD

PG9

PG7

PG11

PG13.

5PG

16PG

21PG

29PG

36PG

42PG

48

M16

M20

M25

M32

M40

PG7

PG9

PG11

PG13.5

PG16

PG21

PG29

PG36

PG42

PG481/2"NPT

B/M16-PG7/TC B/M16-PG9/TC B/M16-PG11/TC – – – – – – –

B/M20-PG7/TC B/M20-PG9/TC B/M20-PG11/TC B/M20-PG13/TC B/M20-PG16/TC B/M20-PG21/TC – – – B/M20-050/TC

– – – – – B/M25-PG21/TC – – – –

– – – – – – B/M32-PG29/TC – – –

– – – – – – – – – –

– B/PG7-PG9/E – – – – – – – –

B/PG9-PG7/R – B/PG9-PG11/E B/PG9-PG13/E – – – – – –

B/PG11-PG7/R B/PG11-PG9/R – B/PG11-PG13/E B/PG11-PG16/E – – – – –

– B/PG13-PG9/R B/PG13-PG11/R – B/PG13-PG16/E B/PG13-PG21/E – – – –

B/PG16-PG7/R B/PG16-PG9/R B/PG16-PG11/R B/PG16-PG13/R – B/PG16-PG21/E – – – –

– – B/PG21-PG11/R B/PG21-PG13/R B/PG21-PG16/R – B/PG21-PG29/E – – –

– – – – B/PG29-PG16/R B/PG29-PG21/R – B/PG29-PG36/E – –

– – – – – B/PG36-PG21/R B/PG36-PG29/R – B/PG36-PG42/E –

– – – – – – B/PG42-PG29/R B/PG42-PG36/R – B/PG42-PG48/E

– – – – – – – B/PG48-PG36/R B/PG48-PG42/R –

– – – – – – – – – –

M10 M16 M20 M25 M32 1 /2" NPT

TO INTERNAL THREAD

TO INTERNAL THREAD

Page 36: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

PERFORMANCE CHARACTERISTICS

The following pages enable you to selectAdaptaflex products which best fit the purposeintended and are designed to help meet yourproduct liability obligations over the lifetime of theinstallation.

To select the most appropriate Adaptaflex systemfor any given application match the performancecriteria required to the relevant tables on thefollowing pages.

Performance criteria used in this table are:

Bending to EN50086 Flexible and pliable conduits can be bent by hand.Flexible systems may flex frequently throughouttheir life and are suitable for both static anddynamic applications.Pliable systems are intended only for staticapplications.

FlexibilityDependent on ease of bending and minimum bendradius without failure.

Fatigue LifeThe recommended maximum number of flexingcycles to avoid failure, dependent on temperature,bend radius and frequency of movement.

Torsional CapabilityDegree of resistance to conduit damage caused bytwisting.

Minimum Dynamic Bend Radius @ MinimumTemperatureThe recommended minimum inside bend radius atthe minimum temperature to EN50086. Fatiguelife in dynamic flexing applications is dependentupon bend radius, frequency of bending,temperature and the chemical environment.

Minimum Temperature to EN50086The minimum operating temperature defined bythe bending classification.

Minimum Static TemperatureThe recommended minimum operating temp-erature in static mode.

Maximum Temperature to EN50086The maximum operating temperature defined bythe bending classification.

Maximum Long Term TemperatureThe recommended maximum operating temp-erature in static mode.

Ultimate Compression StrengthFinal resistance to deformation under compressiveload.

Ultimate Tensile StrengthA combination of final conduit tensile and fittingpull-off resistance.

Abrasion ResistanceAn indication of resistance to rubbing against othermaterials.

UV ResistanceAn indication of suitability for external applicationdependent on resistance to degradation caused byexposure to UV ie. sunlight.

Non-Flame Propogating to EN50086Self-extinguishing within a given time once a firesource is removed.

Halogen FreeGiving off < 0.1% Halogen acid gas when burnt.

Fire Performance (see key on page 35)Systems combining various levels of high flameretardancy, low smoke density and toxicity in theevent of fire are classified as Low Fire Hazard(LFH), Enhanced Low Fire Hazard (ELFH), InherentLow Fire Hazard (ILFH) or Super Low Fire Hazard(SLFH).

EMI Screen @ 1MHz (see on page 41)

are classified as EMIScreen, Enhanced EMI Screen or High EMI Screendependent on capability to reduce electromagneticinterference (EMI) in the frequency range 0.1MHzto 1000 MHz.

System IP Rating to EN50086 (see definitions on page 39)The resistance of an assembled system to theingress of solids and liquids, dependent on thecombination of conduit and fittings.

The point of entry into adjoining equipment mayrequire independent sealing to maintain the systemIP rating, see sealing washers on page 32.

01675

468202

ADAPTAFLEX-IN

FOL

INE

ADAPTASTEELSTEEL FLEXIBLE SYSTEMS

ADAPTALOKADAPTASEALADAPTARINGFLEXIBLE SYSTEMS

HI-SPECFLEXIBLE SYSTEMS

KORIFITPVC PLIABLE SYSTEM &XTRAFLEXFLEXIBLE SYSTEM

STAYFLEXPLIABLE SYSTEM

ADAPTASTEELCOVERED STEEL FLEXIBLE SYSTEMS

ADAPTASTEELOVERBRAIDED FLEXIBLE SYSTEMS

ADAPTASTEELLIQUID TIGHT COVERED STEELFLEXIBLE SYSTEMS

PA LIGHT 13 54 B/GCONDUIT PA STANDARD 10 54 B/G14-15 PA MEDIUM 13 34 B/G

PA HEAVY 13 54 B/GFITTINGS PR 13 54 B16-25 PI 10 54 B/G

PP 13 34 B

PK 16 34 BPKTC 16 34 S

26-27 PKSS 16 34 SPRTC 16 42 SPRSS 16 42 S

KFL 16 50 G28-29 KFS 16 25 W

KFM 12 50 B30 XF 12 50 B

METALLIC SYSTEMS

NON-METALLIC SYSTEMS

PAGE

NUMB

ER

COND

UIT

TYPE

NOMI

NAL S

IZERA

NGE m

mCO

LOUR

/FIN

ISH

( SEE K

EY B

ELOW)

MIN MAX

CONDUITS

COLOUR KEY

4-5S 10 75 SSS 12 32 S

SP 10 75 B/G/O6-7 SN 12 32 B

LFH-SP 16 50 B

SPL 10 63 B/G/O

8-9SPLE 10 63 B/G

SPLHC 16 63 BSPUL 16 63 G

10SB 10 50 SSTC 10 50 S

11SPB 10 50 SSPTC 10 50 S

12 SPLHCB 16 50 S

13 LSP 16 40 S

B = BLACKG = GREYN = NICKEL PLATEO = ORANGES = SELFW = WHITE

34

Page 37: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

Inherent Low Fire Hazard

i.e.Types S, SS & SBconduit and fittings

35

FITTINGS

F VH H † 70 -5 -40 120 120 320 150 M M* ✓ ✓ – –F H H † 70 -5 -40 120 120 350 200 H VH* ✓ ✓ LFH –F M M † – -5 -40 120 120 400 250 H VH* ✓ ✓ LFH –F M M † – -5 -40 120 120 600 350 H VH* ✓ ✓ LFH –F H H † 70 -5 -40 120 120 350 250 H VH* ✓ ✓ ELFH –F VH VH † 30 -25 -50 120 90 250 200 M M* ✓ ✓ – –F VH VH † – -5 -20 105 90 100 100 M M* – ✓ – –

F VH H – – -45 -60 250 250 600 300 VH VH ✓ ✓ SLFH –F VH H – – -45 -60 250 250 600 1200* H VH ✓ ✓ SLFH 98F VH H – – -45 -60 250 250 600 1500 VH VH ✓ ✓ SLFH 61F M H – 70 -5 -40 120 120 350 1200* H VH ✓ ✓ ELFH 98F M H – 70 -5 -40 120 120 350 1500* VH VH ✓ ✓ ELFH 61

P M L – 30 -5 -5 60 60 400 150 M H ✓ – – –P M L – 40 -5 -5 60 60 750 250 M H ✓ – – –P M L – 40 -5 -5 60 60 800 300 M H ✓ – – –P VH M ✓ – -5 -5 60 60 450 150 M M ✓ – – –

COLO

UR/F

INISH

( SEE K

EY B

ELOW)

WHEN

USE

D WI

TH

FITTIN

G RA

NGE

SYSTE

M IP

RATIN

G

TO EN

5008

6

BEND

ING

TO EN

5008

6FLE

XIBILI

TYFAT

IGUE L

IFE

MIN

TO EN

5008

6

MAX

TO EN

5008

6MA

X LO

NG TE

RM

MIN

STATIC

TORS

IONA

L CAP

ABILI

TYMI

N DY

NAMI

C BEN

D RA

DIUS

mm

@ M

IN TE

MP

ULTIM

ATE C

OMPR

ESSIO

N STR

ENGT

H (N

/50m

m)NO

N-FLA

ME PR

OPOG

ATIN

G TO

EN50

086

HALO

GEN

FREE

FIRE P

ERFO

RMAN

CE ( S

EE K

EY B

ELOW)

EMI S

CREE

N @

1MH

z(dB)

(see

page

41)

TYPE

ULTIM

ATE T

ENSIL

E STR

ENGT

H (N

)

ABRA

SION

RESIS

TANC

EUV

RES

ISTAN

CE

TEMPE

RATU

RE R

ANGE

(°C)

66 = AL A/90/FL90/45/Y B/G66 = AL10 A B/G66 = AL PPA B66 = AL SA/SFA/S90/S45/SF45 B/G+N66 = AL UNEF Connectors B67 = AS A/90/FL90/T B/G40 = AR A/90/FL90/T B/G

67 = PK PK N

67 = PB B N

40 = KC A/90 B/G/W66 = KF A/2020 W

65 = XF A/90 BF = FLEXIBLEP = PLIABLE

†WITH ADAPTARING†FITTINGS

*HIGHER*SHORT-TERMMAX TEMPPOSSIBLE

*HIGH*SUSPENDED

LOADCAPABILITY

*BLACK*ONLY

*WITH*LSPS

PERFORMANCE LEVEL KEY FIRE PERFORMANCE CLASSIFICATION KEYPROPERTY LFH ELFH SLFH ILFHOXYGEN INDEX ISO4589 31% ≥ OI ≥ 27% OI ≥ 35% OI ≥ 35%BS6853 APP. B5.1 SMOKE DENSITY 3m3 0.02 ≥ A0 ≥ 0.03 0.005 ≥ A0 ≥ 0.02 A0 ≤ 0.005ZERO HALOGEN ✓ ✓ ✓

ZERO PHOSPHORUS ✓ ✓ ✓

ZERO SULPHUR ✓ ✓ ✓

ZERO NITROGEN ✗ LFH-SP ONLY ✓

TOXICITY INDEX NES713 ISSUE 3 5.0 ≥ TI ≥ 6.0 0.5 ≥ TI ≥ 5.0 TI ≤ 0.5NFF16-102 I3F2 I2F2 I2F0

F H H – 40 -45 -50 250 300 2200 1450 M VH ✓ ✓ ILFH –F H H – 40 -45 -50 250 300 2550 1700 H VH ✓ ✓ ILFH –

F H M – 40 -5 -15 90 70* 2200 1450 M VH ✓ – – –F M M – 50 -25 -40 150 120 2200 1450 H H ✓ ✓ – –F M M – 50 -5 -25 105 90 2200 1450 M H ✓ ✓ ELFH –

F M M – 150 -5 -20 105 105* 2500 1600 M VH ✓ – – –F M M – 150 -5 -15 105 70 2500 1600 M VH ✓ – – –F M H – 50 -45 -65 150 135* 2500 1600 M H ✓ ✓ – –F M M – N/C -5 -15 105 75* 2500 1600 M VH ✓ – – –

F H H – 40 -45 -50 250 300 2200 1450 H VH ✓ ✓ ILFH 74F H H – 40 -45 -50 250 300 2200 1450 H VH ✓ ✓ ILFH 103F H M – 40 -5 -15 90 70* 2200 1450 H VH ✓ – – 74F H M – 40 -5 -15 90 70* 2200 1450 H VH ✓ – – 100F M H – 50 -45 -65 150 135* 2500 3500* H VH ✓ ✓ – 72

P M L – 90 -5 -15 90 70 1050 150 M H ✓ – – 74*

40 = S A/B/F N40 = S C N

54 = SP A/B/F N65 = SP M N00 = SP E N

67 = SPL A/B N67 = SPL M N00 = SPL E N

40 = SB A/B N

54 = SPB A/B N

67 = SPLB A/B N

67 = LSP/LSPS A/S N

L = LOWM = MEDIUMH = HIGHVH = VERY HIGH

Page 38: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

36

CONDUIT & FITTING MATERIALS

ADAPTASTEELSTEEL FLEXIBLE SYSTEMS

ADAPTALOKADAPTASEALADAPTARINGFLEXIBLE SYSTEMS

HI-SPECFLEXIBLE SYSTEMS

KORIFITPVC PLIABLE SYSTEM &XTRAFLEXFLEXIBLE SYSTEM

STAYFLEXPLIABLE SYSTEM

ADAPTASTEELCOVERED STEEL FLEXIBLE SYSTEMS

ADAPTASTEELLIQUID TIGHT COVERED STEELFLEXIBLE SYSTEMS

ADAPTASTEELOVERBRAIDED FLEXIBLE SYSTEMS

METALLIC SYSTEMS

NON-METALLIC SYSTEMS

PAGE

NUMB

ER

COND

UIT

TYPE COND

UIT

OVER

BRAID

COVE

RING

FITTIN

GRA

NGE

FITTIN

GTY

PE

BODY

THRE

ADPA LIGHT PA6 – –

CONDUIT PA STANDARD PA6 – –14-15 PA MEDIUM PA6 – –

PA HEAVY PA6 – –FITTINGS PR PA6 – –16-25 PI MPA – –

PP PP – –

PK PK – –PKTC PK – TC

26-27 PKSS PK – SS316PRTC PA6 – TCPRSS PA6 – SS304

KFL PVCU – –28-29 KFS PVCU – –

KFM PVCU – –30 XF PVCU+PVC – –

AL A/90/FL90/45/Y PA66 PA66AL10 A PA12T PA12TAL PPA PP PPAL SA/SFA/S90/SF90/S45/SF45 PA66+N+EPDM NPBAL UNEF Connectors PA66+N+EPDM AAAS A/90/FL90/T CR+PA66+N+EPDMAR A/90/FL/FL90/T A+PA66 PA66

PK PK NPB NPB

PB B SC+NPB NPB

KC A/90 A+PA66 PA66KF A/2020 PA66 PA66

XF A/90 CR+PA66+N+EPDM PA66*INCLUDES*KRAFT PAPER

LINER

4-5S S – –SS SS316 – –

SP S PVC –6-7 SN S TPE –

LFH-SP S PO –

SPL S PVCOR –

8-9SPLE S PVC –

SPLHC S TPR –SPUL S PVCOR –

10SB S – SSTC S – TC

11SPB S PVC SSPTC S PVC TC

12 SPLHCB S TPR SS304

13 LSP LS* PVC –

S A/B/F NPB NPBS C NPB –

SP A/B/F NPB NPBSP M A+NPB+N+EPDM NPB/PA6SP C/E NPB –

SPL A/B PA6+NPB+N+EPDM NPB/PA6SPL M A+NPB+N+EPDM NPB/PA6SPL E NPB –

SB A/B NPB NPB

SPB A/B NPB NPB

SPLB A/B PA6+NPB+N+EPDM NPB/PA6

LSP/LSPS A/S NPB NPB

01675

468202

ADAPTAFLEX-IN

FOL

INE

This chart is designed to assist product selection bydetailing the material types of the main componentswhich make up a particular conduit system, i.e.conduit, covering, overbraid, fitting body & thread.

The full names for the abbreviated material types canbe found on the next page in the materials key.

COND

UIT M

ATER

IALS

FITTIN

G MA

TERIAL

S

Page 39: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

37

CHEMICAL RESISTANCE

To assess the chemical resistance of an assembled system:

■ from the Materials Key, compare the material of the conduit &fittings selected, against the main chemical of concern in this chart.

■ the least suitable material determines the overall chemicalresistance of the system. Phone the Adaptaflex Infoline for otherchemicals, concentrations and temperatures.

A=

Aceta

l (PO

M)AA

=An

odise

d alu

miniu

mB

=Br

ass

C=

Copp

erCR

=Ch

lorop

rene

rubb

erE

=EP

DMLS

=Le

aded

stee

lM

PA=

Modifi

ed P

olyam

ide (n

ylon)

N=

Nitri

le (N

BR)

NPB

=Ni

ckel

plated

bra

ssPA

6=

Polya

mide

(nylo

n) 6

PA12

=Po

lyami

de (n

ylon)

12

PA12

T=

Polya

mide

(nylo

n) 1

2TPA

66=

Polya

mide

(nylo

n) 6

6PK

=Po

lyketo

nePO

=Po

lyolefi

nPP

=Po

lypro

pylen

ePU

=Po

lyure

than

ePV

C=

PVC

PVCO

R=

Oil r

esist

ant P

VCPV

CU=

Unpla

sticis

ed P

VCS

=Ga

lvanis

ed st

eel

SC=

Silico

ne (Q

)SS

304

=Sta

inles

s stee

l gra

de 3

04SS

316

=Sta

inles

s stee

l gra

de 3

16TC

=Tin

ned

copp

erTP

E=

Ther

mopla

stic e

lasto

mer

TPR

=Th

ermo

plasti

c rub

ber

S S S S S U S S S S S S S SS S S S L U S S S S S S S SS S S S U U S S L S S S S SS S U L S S U L S S L L S LL S S S L S S S U S S S U SL S U L S S U S S A L S S LS S S S L S S U U S L U U LS S S S U S S L U S L L L LS S S S U U S S U S S S S SS S S S U U S S U S S S L SU L U U L L U U U S U U U UL S S S U U S U U S U U U LS S S S S S S S S S S S S SS S S S S S S S S S L S S LU S L L L U S U U S U U U US S S S L U S S S S S S S SU S S S U U S L U S S L U SS S S S S S S L S S S L U SS S S S L U S S U S S S S SL S S S U S S L S S S L U SS S S S S S U S S S S S S SS S S S U S S S S S L S S LS S S S S S U S S S S S S SL L U U S S U L S S U L L UU L U U S L U U S S U U U UU S U S S S U L S S L L L LU S U L U A U U S S U U U UU L L S S S U S S S L S L LS S S S S U S S S S S S S SS S S S S S S L S S L L L LU S S S U U S U S S U U U US S S S U S S S S S S S L SL L U U L S U U S S U U L UU L U U U U U U S S U U U UL S U L S S U S S S L S A LU S S S L S U U S S U U L US S S S L U S S S S S S S SS S S S U U S S S S S S S SU S L L L S S U S S U U U US S L S S S U S S L S S S SS S U S S S U S S S S S S SS S S S L L S S S S S S A SS S U S S S U S S L S S S SS U U S S S U S S S S S S SS U U S S S U L S S S L S SU L U L L S U U L U U U L UU L U U S S U L S U U L L UU L U U L S U U U U U U U US S S S U U S S U S S S S SS S S S L U S S S S S S S SS S S S U U U S U S S S S SL S S S U U U U U S L U S LS S S S U U S S S S S S S SS S S S S L S S S S S S S SL S S S S U U S L S L S S LS S S S S S U S S S S S S SS S S S L U S S S S S S S SS L U L S S U S S S U S S U

ASTM NO.1ASTM NO.2ASTM NO.3ACETIC ACID (10%)ACETONEALUMINIUM CHLORIDEANILINEBENZALDEHYDEBENZENECARBON TETRACHLORIDECHLORINE WATERCHLOROFORMCITRIC ACIDCOPPER SULPHATECRESOLDIESEL OILDIETHYLAMINEETHANOLETHERETHYLAMINEETHYLENE GLYCOLETHYL ETHANOATEFREON 32HYDROCHLORIC ACID (10%)HYDROCHLORIC ACID (36%)HYDROGEN PEROXIDE (35%)HYDROGEN PEROXIDE (87%)LACTIC ACIDLUBRICATING OILMETHANOLMETHYL BROMIDEMEKNITRIC ACID (10%)NITRIC ACID (70%)OXALIC ACIDOZONE (GAS)PARAFFIN OILPETROLPHENOLSEA WATERSILVER NITRATESKYDROLSODIUM CHLORIDESODIUM HYDROXIDE (10%)SODIUM HYDROXIDE (60%)SULPHUR DIOXIDE (GAS)SULPHURIC ACID (10%)SULPHURIC ACID (70%)TOLUENETRANSFORMER OIL1,1,1-TRICHLOROETHANETRICHLOROETHYLENETURPENTINEVEGETABLE OILVINYL ACETATEWATERWHITE SPIRITZINC CHLORIDE

S L S S U S S S S S S S S SS L S S U S S S S S S S S LS L L S U S S S L S S S S LS S S L L S S U S S S L S SS U S L U U U S L S S S U SS S S S L S S U L U L L L SL L S U U U U S S S S S L SS U L L U U U S L S S S L LS U L L U U U S U S S S U US U L L L L L S U S S S U LU L L U U U L U L U U U U SS U L L U U U S U S S S U LS S S S S S S S S S S S S SS S S S S S S S S S S S S SL U S U L L L S U S S L L SS L S S L S S S U S S S S SS S S U L L L S L S S S L SS L S L U U S S S S S S L SS U S S L L S S U S S S L SS L S U L L L S U S S S L LS S S S L L S U S S S S L SS U S U U U U S L S S S U SS U S L L L L U U S S S U US U S L S S S U L U U U S SS U S U L S S U U U U U U SS L S U S S S U S S S S L LS U L U S S S U L S S L U US S S S L L L U L S S S S LS L S S L S S S U S S S S LS L S L U U S S S S S S L SS U L U U U U S U S S S U LS U S L U U U S U S S S U SS S S U S S S U L U U U U SU U S U S S S U U U U U U SS S S L L S S U L S S L S SS S L S L L S U S S S S S LS L S S L S S S U S S S S SS U S S U S S S U S S S S SL U S L L L L S S S S L L SS S S S S S S U S L S S S SS S S S S S S U S S S S S SS U S L U U U S L S S S L SS S S S S S S U S L S S S SS S S S S S S U S S S S S SS S S L L S S U S L L S L SS L S U S S S U S U U L L SS S S L S S S U L U U U L SU L S U S S S U U U U U U SS L S U U U U S U S S S U US L S S L S S S L S S S S LS L L L U U U U U S S S U LS L L L U U U U U S S S U US U U L L L S S U S S S L US L S S L S S S L S S S S SS U S U U U U U U S S S U SS S S S S S S U S S S S S SS U S L L L S S U S S S L LS S S S S S S U S S S L L S

MATERIALS KEY

SUITABILITY KEY

S = SUITABLEL = LIMITED SUITABILITYU = UNSUITABLEA = CONTACT ADAPTAFLEX

INFOLINE

Page 40: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

SUSP

ENDE

D LO

AD

CAPA

CITY (

N)

NON-

FLAME

PROP

OGAT

ING

TENSIL

ESTR

ENGT

H (N

)

CORR

OSIO

NRE

SISTA

NCE

IP RA

TING

(WAT

ER IN

GRES

S)

IP RA

TING

(SOLID

INGR

ESS)

ELECT

RICAL

PROP

ERTIE

S

BEND

ING

MAXIM

UMTEM

PERA

TURE

(°C)

MINI

MUM

TEMPE

RATU

RE (°

C)

IMPA

CTSTR

ENGT

H (J)

COMP

RESS

ION

STREN

GTH

(N)

CLAS

SIFICA

TION

LEVEL

38

EN50086 CLASSIFICATIONS

METALLIC SYSTEMS

NON-METALLIC SYSTEMS

12 SUSP

ENDE

D LO

AD

11 NON-

FLAME

PROP

AGAT

ING

WITH

FIT

TING

10 TENSIL

E

9 CORR

OSIO

N

8 LIQUI

D IN

GRES

S (IP)

7 SOLID

INGR

ESS (

IP)

6 ELECT

RICAL

5 BEND

ING

4 MAX.

TEMP.

3 MIN.

TEMP.

2 IMPA

CT

1 COMP

RESS

ION

Information based on nominal 20mm conduit size

In 1995/96 the new European standards for flexible and pliableconduit systems (BS EN 50086-2.3 & BS EN 50086-2.2)were published by BSI.

This is the first European standard for such conduit systemsand has been written to conform to the Low Voltage Directive(LVD) and the Construction Product Directive (CPD).

EN50086 is a performance standard which identifies keyproduct characteristics (detailed below). For each of thesecharacteristics there are recommended tests with associatedperformance classifications.

The adjacent table and key allow you to check productsuitability in line with the EN50086 performanceclassifications.

Compression Strength (Performance Classification 1)Resistance to deformation under compressive load.

Impact Resistance (Performance Classification 2)Resistance to brittle fracture and deformation under impact.

Minimum Temperature to EN50086 (Performance Classification 3)The minimum operating temperature defined by the bendingclassification.

Maximum Temperature to EN50086(Performance Classification 4)The maximum operating temperature defined by the bendingclassification.

Bending to EN50086 (Performance Classification 5)Flexible and pliable conduits can be bent by hand.Flexible systems may flex frequently throughout their life andare suitable for both static and dynamic applications.Pliable systems are intended only for static applications.

Electrical Properties (Performance Classification 6)Metallic systems defined as electrical conductors or insulators.

System IP Rating to EN50086 (Performance Classifications 7 & 8)(see definitions on page 39)The resistance of an assembled system to the ingress of solidsand liquids, dependent on the combination of conduit andfittings.

The point of entry into adjoining equipment may requireindependent sealing to maintain the system IP rating, seesealing washers on page 32.

Corrosion (Performance Classification 9)Metallic systems defined by their resistance to corrode underexposure to water vapour.

Tensile Strength(Performance Classification 10)Resistance of a system to a short term tensile load at ambienttemperature.

Non-Flame Propogating to EN50086 (Performance Classification 11)Self-extinguishing within a given time once a fire source isremoved.

Suspended Load Capability (Performance Classification 12)Resistance of a fitting to a high continuous tensile load atmaximum temperature.

S S 4 4 5 6 4 0 4 0 1 4 1 0SS S 4 4 5 6 4 0 4 0 4 4 1 0

SP SP(M) 4 4 2 2 4 2 6 5 0 4 1 0SN SP(M) 4 4 4 5 4 0 6 5 0 4 1 0

LFH-SP SP(M) 4 4 2 3 4 0 6 5 0 4 1 0

SPL SPL(M) 4 4 2 3 4 2 6 7 0 4 1 0SPLE SPL(M) 4 4 2 3 4 2 6 7 0 4 1 0

SPLHC SPL(M) 4 4 5 5 4 0 6 7 0 4 1 0SPUL SPL(M) 4 4 2 3 4 2 6 7 0 4 1 0

SB SB 4 4 5 6 4 1 4 0 1 4 1 0STC SB 4 4 5 6 4 1 4 0 1 4 1 0SPB SPB 4 4 2 2 4 3 5 4 0 4 1 0SPTC SPB 4 4 2 2 4 3 5 4 0 4 1 0

SPLHCB SPLB 4 4 5 5 4 1 6 7 0 5 1 0

LSP LSP(A) 3 4 2 2 2 2 6 7 0 1 1 0

PA LIGHT AL 2 4 2 4 4 0 6 6 0 1 1 0PA STANDARD AL 2 4 2 4 4 0 6 6 0 1 1 0PA MEDIUM AL 2 4 2 4 4 0 6 6 0 1 1 0PA HEAVY AL 2 4 2 4 4 0 6 6 0 1 1 0

PR AL 2 4 2 4 4 0 6 6 0 1 1 0PI AL 1 3 4 4 4 0 6 6 0 1 1 0PP AL 2 3 2 3 4 2 6 6 0 2 2 0

PK PK 2 4 5 6 4 3 6 7 0 3 1 0PKTC PB 2 4 5 6 4 3 6 7 0 3 1 0PKSS PB 2 4 5 6 4 3 6 7 0 3 1 0PRTC PB 2 4 2 4 4 1 6 7 0 3 1 0PRSS PB 2 4 2 4 4 1 6 7 0 3 1 0

KFL KC 2 2 2 1 2 2 4 0 0 1 1 0KFS KC 2 3 2 1 2 2 4 0 0 2 1 0KFM KC 3 3 2 1 2 2 4 0 0 1 1 0

0 – – – – – Not declared – 0 N/A Not declared – Not declared

1 125 0.5 5 60 Rigid Conductor – 1 Low 100 ✓ 20

2 320 1 -5 90 Pliable Insulator – 2 Medium 250 ✗ 30

3 750 2 -15 105 Pli/Semi Rigid Con/Ins 3 3 Med-Hi 500 – 150

4 1250 6 -25 120 Flexible – 4 4 High 1000 – 450

5 4000 20 -45 150 – – 5 5 – 2500 – 850

6 – – – 250 – – 6 6 – – – –

7 – – – – – – – 7 – – – –

PERFORMANCE CLASSIFICATION KEY

Page 41: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

39

THREAD DATA, IP RATINGS& CABLE CARRYING CAPACITY

M8 8.0 6.9 1.0

M10 10.0 8.9 1.0

M12 12.0 10.9 1.0

M16 16.0 14.4 1.5

M18 18.0 16.9 1.0

M20 20.0 18.4 1.5

M25 25.0 23.4 1.5

M30 30.0 28.4 1.5

M32 32.0 30.4 1.5

M40 40.0 38.4 1.5

M50 50.0 48.4 1.5

M63 63.0 61.4 1.5

M75 75.0 73.4 1.5

THREAD SI

ZE

mm EXT TH

READ

OUTSIDE D

IAMETE

R

INT THREA

D

INSIDE D

IAMETE

R

PITCH

Thread DataMETRICStandard thread conforming toEN60423 & BS3643

PG7 12.5 11.3 1.27

PG9 15.2 13.9 1.41

PG11 18.6 17.3 1.41

PG13.5 20.4 19.1 1.41

PG16 22.5 21.2 1.41

PG21 28.3 26.8 1.59

PG29 37.0 35.5 1.59

PG36 47.0 45.5 1.59

PG42 54.0 52.5 1.59

PG48 59.3 57.8 1.59

THREAD SI

ZE

EXT TH

READ

OUTSIDE D

IAMETE

R

INT THREA

D

INSIDE D

IAMETE

R

PITCH

PGGerman Standard thread conforming toDIN40430

1/4 – – –3/8 16.7 – –1/2 21.0 18.6 1.813/4 26.4 24.1 1.81

1 33.3 30.3 2.31

11/4 41.9 39.0 2.31

11/2 47.8 44.8 2.31

2 59.6 56.7 2.31

THREAD SI

ZE

(inche

s)EXT

THREA

D

OUTSIDE D

IAMETE

R

INT THREA

D

INSIDE D

IAMETE

R

PITCH

5/8 15.9 14.7 1.063/4 19.1 17.7 1.277/8 22.2 20.9 1.27

1 25.4 24.0 1.27

13/16 30.2 28.6 1.41

11/4 31.8 30.2 1.41

17/16 36.5 35.0 1.41

13/4 44.5 42.9 1.41

2 50.8 49.3 1.41

21/4 57.2 55.4 1.41

THREAD SI

ZE

(inche

s)EXT

THREA

D

OUTSIDE D

IAMETE

R

INT THREA

D

INSIDE D

IAMETE

R

PITCH

PFJapanese conduit thread conforming to JIS B 0202

3/8 16.7 1.141/2 21.0 1.813/4 26.4 1.81

1 33.3 2.21

11/4 41.9 2.21

11/2 47.8 2.21

2 59.6 2.21

THREAD SI

ZE

(inche

s)EXT

THREA

D

OUTSIDE D

IAMETE

R

PITCH

NPTUS taper seal pipe threadconforming to ANSI/ASMEB1.20.1 – 1983

1.0 6.6

1.5 7.6

2.5 9.6

4.0 14.5

6.0 18.8

10.0 29.3

16.0 40.2

25.0 63.8

35.0 83.5

50.0 113.0

70.0 149.0

95.0 204.0

NOMINAL

CONDUCTO

R SIZE

(mm2 ) NOMINAL

OVERALL

CROSS

SECTIO

NAL

AREA (

mm2 )

UNEFAmerican Unified Thread conforming toBS1580

NOTE: Dimensions are nominal & in mm unless otherwise stated.

IP RatingsThe degree of ingress protection is indicated by two digits followingthe letters IP. The first refers to protection against the ingress of solidobjects, the second refers to protection against the ingress of water.

Cable Carrying CapacityUK wiring regulations, BS7671 recommend that the total cross sectional area of the sum of the individual cables shouldnot exceed 40% of the cross sectional area of the conduit. The nominal cross sectional area of single-core, stranded,PVC insulated cables is provided as a guide only. Other cables may have different dimensions.

Protection against solids Protection against water1st Digit 2nd Digit

Protection againstsolid bodies larger than 1mm

Protection againstdust (no harmfuldeposits)

Complete protectionagainst dust

ExampleAdaptalok system is IP66which provides completeprotection against dust andprotection against jets ofwater of similar force toheavy seas.

456

No protection

Protection againstprojections of waterfrom all directions

Protection against jetsof water from all directions

Protection against jetsof water of similarforce to heavy seas

Projection againstingress of water to adepth of 1 metre

04567

Example: Is SP20 suitable for five 4.0mm2 & two 1.5mm2 cables?

■ The total cross sectional area of the conductors is 5 x 14.5mm2

(for 4.0mm2 conductors) + 2 x 7.6mm2 (for 1.5mm2 conductors) = 87.7mm2

■ The cross sectional area of SP20 is 3.142 x [ Inside Diameter ]2 = 224mm2

2■ % of conduit cross sectional area [ (a) ] x 100 = 39.1%

(b)This is less than 40% therefore this conduit is suitable for this combination of cables.

The easiest way of installing cables into flexible & pliable conduit is to simultaneouslydraw in the cables with the conduit in straight condition before installation. UK wiringregulations prohibit the use of flexible or pliable conduit as an earthing conductor. Pleasephone the Adaptaflex Infoline for further guidance.

Page 42: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

40

INTERNATIONAL APPROVALS

METALLIC SYSTEMS NON-METALLIC SYSTEMS

COND

UIT

TYPE WI

THFIT

TING

KITE M

ARK

BSEN

5008

6CE

LVD

LLOYD

S

NF R

13-90

3

LUL

COMP

LIANC

E

COND

UIT

TYPE WI

THFIT

TING

KITE M

ARK

BSEN

5008

6CE

LVD

LLOYD

S

LUL

COMP

LIANC

EDI

N551

0

NFF16

-102

As a worldwide supplier of conduit systems, Adaptaflex has an expanding portfolio ofinternational approvals obtained from the various organisations indicated below.

The table shows the relevant approvals obtained for each conduit system.

Since approvals are constantly being added, audited & updated, please phone the AdaptaflexInfoline for the latest details.

GlossaryFire Performance

Adaptaflex has introduced a set of symbols to help the user specify conduit systems forinstallations where fire performance is of particular concern.

Each symbol encompasses a range of properties relevant to the high specification materialsused in the construction of the conduit.

They are in an ascending scale of performance from Low Fire Hazard (LFH) featuring zerohalogen through to Super Low Fire Hazard (SLFH) featuring zero nitrogen. In addition,Inherent Low Fire Hazard systems (ILFH) are classified as being all metal systems.

For more detailed information on fire performance classifications, see the key on page 35.

LO

W

FIRE HAZ

AR

DLFH•LO

W

FIRE HAZAR

D• LO

W

FI R E H A

ZA

RDELFH•

E

NHANCE

D•

SU

PE

RLOW FIRE H

A

ZA

RDSLFH•

SU

PE

RLOW FIRE HA

ZA

RD

LO

W

FI R E H A

ZA

RDILFH•

INHEREN

T•

LOW FIRE HAZARD

ENHANCED LOW FIRE HAZARD

SUPER LOW FIRE HAZARD

INHERENT LOW FIRE HAZARD

S S ✓ ✓ – – –SS S ✓ ✓ – – –

SP SP(M) ✓ ✓ – – –SN SP(M) ✓ ✓ – – –

LFH-SP SP(M) ✓ ✓ ✓ – FULL

SPL SPL(M) ✓ ✓ ✓ UR –SPLE SPL(M) – ✓ – – –

SPLHC SPL(M) – ✓ – – –SPUL – ✓ – UL+CSA –

SB SB ✓ ✓ – – –STC SB ✓ ✓ – – –SPB SPB ✓ ✓ – – –SPTC SPB ✓ ✓ – – –

SPLHCB SPLB ✓ ✓ – – –

LSP LSP ✓ ✓ – – –

PA LIGHT AL ✓ ✓ – UR – – ✓ –PA STANDARD AL ✓ ✓ ✓ UR ✓ CONCESSION ✓ I4F3PA MEDIUM AL ✓ ✓ ✓ UR ✓ CONCESSION ✓ I3F2PA HEAVY AL ✓ ✓ ✓ UR ✓ CONCESSION ✓ I3F2

PR AL ✓ ✓ – UR – CONCESSION ✓ I2F2PI AL ✓ ✓ – UR – – ✓ –PP AL – ✓ – – – – – –

PK PK ✓ ✓ – – – FULL – I2F1PKTC PB – ✓ – – – FULL – I2F1PKSS PB – ✓ – – – FULL – I2F1PRTC PB – ✓ – – – CONCESSION – I2F2PRSS PB – ✓ – – – CONCESSION – I2F2

KFL KC 16 - 25 ✓ – – – – – –KFS KC 16 - 25 ✓ – – – – – –KFM KC 16 - 25 ✓ – – – – – –XF XF – ✓ – – – – – –

Page 43: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

ADAPTAFLEX TRADE MARKSAdaptaflex, Adaptaflex Screen Systems, Adaptaflex Hi-Spec Systems, Adaptalok, Adaptaring, Adaptaseal,Adaptasteel, Korifit, Stayflex & Xtraflex.

ADAPTAFLEX PATENTSAdaptalok fittings; type KF Korifit fittings; type BAdaptasteel fittings; type AWB anti-vibration washer;pending on type ACB/ACG conduit clips.

ERRORS, OMISSIONS & AMENDMENTS EXCEPTEDInformation given in this document was correct to the bestof our knowledge at the original publication date and isfor guidance only.

Adaptaflex is not liable for claims arising from productmisuse.

Our policy is one of continuous development andspecifications may change at any time.

ACKNOWLEDGEMENTSMetaltech

Neil Barker

Burton Daily Mail Ltd

The European Directive on Electromagnetic Compatibility (EMC) 89/336/EEC requires any electrical equipment/installation to be constructed so that if neither produces Electromagnetic Interference (EMI), sufficient to interferewith radio and telecommunications equipment, nor is itself affected by EMI.

All conduit systems are considered electrically passive since they do not produce or are affected by EMI. However,Adaptaflex has introduced a new range of “Screen Systems” which offer a cost-effective alternative to individuallyscreened cables within applications where cross talk has no adverse effect.

Additionally the user gains the mechanical advantages of a conduit system and a simplified means of modification;e.g. addition, substitution or replacement of cables in an existing cable run.

The graph below shows the results of different types of 20/21mm diameter screened conduit, with its appropriatefittings, tested by ERA Technology, to IEC96/2:93 (Radio frequency cables Part 1). Tests measured attenuationin decibels (dB) over the frequency range covered by the EMC Directive, 0.1 to 1000MHz. The test data allowscomparison with other screened conduit systems, and cables tested to IEC 96-1.

10.1 10

Frequency (MHz)100 1000

0

10

20

30

40

50

60

70

80

90

100

110

120

Atte

nuat

ion

(dB

)

HIGH EMI SCREENSTC

SPTC

PRTC/PKTC

ENHANCED EMI SCREENLSPS

SB/SPB

STANDARD EMI SCREENSPLHCB

PRSS/PKSS

EMI

EMI Screen Systems

For applications where electromagneticinterference is of particular concern wehave classified suitable conduit systemsby means of symbols. These are relatedin an ascending scale of performancefrom Standard EMI Screen (productsfeaturing a stainless steel overbraid)through to High EMI Screen (productsfeaturing a tinned copper overbraid).

For more detailed information see above.

EMI

S

CR

EE

N•

E

MI S C R EEN

•E

MI

SC

R

EEN•

STANDARD

EMI

S

CR

EE

N•

E

MI S C R EEN

•E

MI

SC

R

EEN•

ENHANCED

EMI

S

CR

EE

N•

E

MI S C R EEN

•E

MI

SC

R

EEN•

HIGHSTANDARD

EMI SCREENENHANCED EMI SCREEN

HIGH EMI SCREEN

FITTING OR THREAD SWIVELSINDEPENDENTLY OF CONDUIT

DURING INSTALLATION

FITTING ROTATESINDEPENDENTLY OF THECONDUIT TO ACT AS A

ROTATING JOINT WITHINCONSTANTLY MOVING

APPLICATIONS

Fitting Characteristics

41

Page 44: Flexible & Pliable Conduit Systems To return to Adaptaflex ... · – – pg7 sp10/pg7/a m16 sp12/m16/a pg9 sp12/pg9/a m16 sp16/m16/a pg11 sp16/pg11/a m20 sp16/m20/a pg11 sp16/pg11/a

Adaptaflex LimitedStation Road, Coleshill, Birmingham B46 1HT, UK

UK Sales: (+44) 01675 468200

UK Fax: (+44) 01675 464930

Export Sales: (+44) 01675 468246

Export Fax: (+44) 01675 464944

Switchboard: (+44) 01675 468222

A40/1-3-97