floor - contraction joint · sikaswell p profile 2010h waterbars scale 1:10 precast wall / in-situ...

12
Floor - Contraction Joint Site Concrete Floor slab Reinforcing shown indicative only Site Concrete Reinforcing shown indicative only 200mm Sika RearFix PVC waterbar Floor slab 200mm Sika RearFix PVC waterbar Waterbars Scale 1:10 Floor Joints - RearFix PVC - Section Detail no: WB01 - Nov 2013

Upload: others

Post on 04-Aug-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Floor - Contraction Joint · SikaSwell P Profile 2010H Waterbars Scale 1:10 Precast Wall / In-situ - Section Detail no: WB03 - Nov 2013. In-situ stitch joint (Dotted) 200mm Sika RearFix

Floor - Contraction Joint

Site Concrete

Floor slab

Reinforcing shownindicative only

Site Concrete

Reinforcing shownindicative only

200mm Sika RearFixPVC waterbar

Floor slab

200mm Sika RearFixPVC waterbar

Waterbars

Scale 1:10

Floor Joints - RearFix PVC - Section

Detail no: WB01 - Nov 2013

jktan
Stamp
Page 2: Floor - Contraction Joint · SikaSwell P Profile 2010H Waterbars Scale 1:10 Precast Wall / In-situ - Section Detail no: WB03 - Nov 2013. In-situ stitch joint (Dotted) 200mm Sika RearFix

Reinforcing shownindicative only

Reinforcing shownindicative only

Wall - Contraction Joint

200mm Sika RearFixPVC waterbar

200mm Sika RearFixPVC waterbar

Wall - Expansion Joint

Waterbars

Scale 1:10

Floor Joints - RearFix PVC - Plan

Detail no: WB02 - Nov 2013

jktan
Stamp
Page 3: Floor - Contraction Joint · SikaSwell P Profile 2010H Waterbars Scale 1:10 Precast Wall / In-situ - Section Detail no: WB03 - Nov 2013. In-situ stitch joint (Dotted) 200mm Sika RearFix

10

0 M

in.

Strip footing

Grout under precast panel and water bar

200mm Sika Rearfix PVC waterbarto horizontal joints

Sika Grout 212

200mm Sika RearFix PVC waterbarto vertical joints

200mm Sika RearFix PVC waterbarto vertical joints

SikaSwell P Profile 2010H

Waterbars

Scale 1:10

Precast Wall / In-situ - Section

Detail no: WB03 - Nov 2013

jktan
Stamp
Page 4: Floor - Contraction Joint · SikaSwell P Profile 2010H Waterbars Scale 1:10 Precast Wall / In-situ - Section Detail no: WB03 - Nov 2013. In-situ stitch joint (Dotted) 200mm Sika RearFix

In-situ stitch joint (Dotted)

200mm Sika RearFix PVC waterbar

RearFix - Stitch Joint

- Isometric View

Scale 1:10

Waterbars

Detail no: WB04 - Nov 2013

jktan
Stamp
Page 5: Floor - Contraction Joint · SikaSwell P Profile 2010H Waterbars Scale 1:10 Precast Wall / In-situ - Section Detail no: WB03 - Nov 2013. In-situ stitch joint (Dotted) 200mm Sika RearFix

40

04

00

Pre-cast panel

Pre-cast panel

Pre-cast panel

Pre-cast panel

Min

. In

-situ s

titc

hM

in.

In-s

itu s

titc

h

Floor construction joint

200mm Sika RearFix PVC waterbar

200mm Sika RearFix PVC waterbar

Scale 1:10

Waterbars

RearFix - Stitch Joint

- Plan View

Detail no: WB05 - Nov 2013

jktan
Stamp
Page 6: Floor - Contraction Joint · SikaSwell P Profile 2010H Waterbars Scale 1:10 Precast Wall / In-situ - Section Detail no: WB03 - Nov 2013. In-situ stitch joint (Dotted) 200mm Sika RearFix

400

40

0

Scale 1:10

Pre-cast panel

Min. In-situ stitch

Min

. In

-situ s

titc

h

Pre-cast panel

Pre-cast panel

Waterbars

Pre-cast panel

200mm Sika RearFix PVC waterbar

200mm Sika RearFix PVC waterbar

RearFix - Internal Corner

- Plan View

Detail no: WB06 - Nov 2013

jktan
Stamp
Page 7: Floor - Contraction Joint · SikaSwell P Profile 2010H Waterbars Scale 1:10 Precast Wall / In-situ - Section Detail no: WB03 - Nov 2013. In-situ stitch joint (Dotted) 200mm Sika RearFix

400

200 Min.

400

200 Min.

200mm Sika RearFix PVC waterbar

200mm Sika RearFix PVC waterbar

Each way

Min

. In

-situ s

titc

hM

in.

In-s

itu s

titc

h

Pre-cast panel

Each way

Pre-cast panel

Detail no: WB07 - Nov 2013

RearFix - External Corner

- Plan View

Scale 1:10

Waterbars

jktan
Stamp
Page 8: Floor - Contraction Joint · SikaSwell P Profile 2010H Waterbars Scale 1:10 Precast Wall / In-situ - Section Detail no: WB03 - Nov 2013. In-situ stitch joint (Dotted) 200mm Sika RearFix

200mm

SikaSwell P Profile 2010H

RearFix PVC Waterbar - Pre-cast Lift Pit

200mm Sika RearFixPVC waterbar

Ensure no clash betweenreinforcing steel and waterbar

200mm Sika centre placed PVC waterbar

Detail no: WB08 - Nov 2013

Scale 1:10

Waterbars

Lift Pit - RearFix PVC

- Section

jktan
Stamp
Page 9: Floor - Contraction Joint · SikaSwell P Profile 2010H Waterbars Scale 1:10 Precast Wall / In-situ - Section Detail no: WB03 - Nov 2013. In-situ stitch joint (Dotted) 200mm Sika RearFix

200mm Sika Centre Placed PVC waterbar

Ensure no clash betweenreinforcing steel and waterbar

Centre Placed PVC Waterbar - In-situ Lift Pit

Reinforcing shownindicative only

Scale 1:10

200mm Sika Centre Placed PVC waterbar

Reinforcing shownindicative only

Ensure no clash betweenreinforcing steel and waterbar

Centre Placed PVC Waterbar - Pre-cast Lift Pit

Waterbars

Detail no: WB09 - Nov 2013

Lift Pit - Centre Placed PVC

- Section

jktan
Stamp
Page 10: Floor - Contraction Joint · SikaSwell P Profile 2010H Waterbars Scale 1:10 Precast Wall / In-situ - Section Detail no: WB03 - Nov 2013. In-situ stitch joint (Dotted) 200mm Sika RearFix

Reinforcing shownindicative only

Wall Expansion Joint

Reinforcing shownindicative only

Wall - Contraction Joint

200mm Sika Centre Placed PVC waterbar

200mm Sika Centre Placed PVC waterbar

Scale 1:10

Waterbars

Detail no: WB10 - Nov 2013

Wall Joints - Centre Placed PVC

- Plan

jktan
Stamp
Page 11: Floor - Contraction Joint · SikaSwell P Profile 2010H Waterbars Scale 1:10 Precast Wall / In-situ - Section Detail no: WB03 - Nov 2013. In-situ stitch joint (Dotted) 200mm Sika RearFix

SikaSwell Profile

Floor & Wall - Contraction Joint(Cannot be used for Expansion joint refer PVC waterbars)

Reinforcing shownindicative only

Detail no: WB11 - Nov 2013

Scale 1:10

Floor & Wall Joints -

SikaSwell Profile - Section or Plan

Waterstops

jktan
Stamp
Page 12: Floor - Contraction Joint · SikaSwell P Profile 2010H Waterbars Scale 1:10 Precast Wall / In-situ - Section Detail no: WB03 - Nov 2013. In-situ stitch joint (Dotted) 200mm Sika RearFix

200mm

Scale 1:10

Lift Pit - SikaSwell Profile

- Elevation

Detail no: WB12 - Nov 2013

SikaSwell P Profile 2010H

Reinforcing shownindicative only

Reinforcing shownindicative only

SikaSwell Profile - Pre-cast Lift Pit

SikaSwell P Profile 2010H

SikaSwell Profile - In-situ Lift Pit

Waterstops

jktan
Stamp