All rights reserved 02/14 SSc
PCSPH1411
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.
Cautions on product corrosion
Warning Ask a installer or contractor to install this product. Do not try to install the product by yourself. Improper installation can result in water or refrigerant leakage, electrical shock, or explosion.
Use only those parts and accessories supplied or by Daikin. Ask a installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
out notice.
!"#$"%&'()*+$,,%-*.#(/0,(*123#%"-*45*1#(*6783"$*9:"(3"-*;%078#/*<"(0"%-*=#/78*<70>-*4?@AB"$C*D,C&**E@'F*GH'I?J@@KGH'I?5G'+#L*D,C&*E@'F*GH'I?5GM
Daikin meets your needs with this full lineup of inverters for various types of indoor units and power supplies.
1 2
FCQ50KVEA
71 100 125 14050 603HP 4HP 5HP 6HP2HP 2.5HP
FCQ60KVEA
FBQ50DAVET FBQ60DAVET
FVQ50CVE FVQ60CVE
RZR50LVVM RZR60LVVM
FCQ71KVEA FCQ100KVEA
FHQ71CAVEB FHQ100CAVEB
FAQ71CVEA
FBQ71DAVET
FAQ100CVEA
FBQ100DAVET
FCQ125KVEA FCQ140KVEA
FCQ100KVLT FCQ125KAVLT FCQ140KAVLT
FBQ100DAVET FBQ125DAVET FBQ140DAVET
FCQ60KVEAX2 FCQ71KVEAX2
FHQ125CAVEB
FBQ125DAVET
FHQ140CAVEB
FBQ140DAVET
FVQ71CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB
RZR125LVVM RZR140LVVM
FBQ60DAVETX2 FBQ71DAVETX2
FVQ60CVEX2 FVQ71CVEBX2
Indoor unit
Indoor unit
CEILING MOUNTED CASSETTE TYPE
Round Flow
Indoor unit
CEILING SUSPENDED TYPE
Indoor unit
WALL MOUNTED TYPE
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
FLOOR STANDING TYPE
Indoor unit
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
Indoor unit
Indoor unit
FLOOR STANDING TYPE
Indoor unit
Outdoor unit
Series
RZR71LVVM RZR100LVVM
OUTDOOR UNIT
CEILING MOUNTED CASSETTE TYPE
Round Flow
3 Phase, 220 V3 Phase, 380 V
1 Phase, 220–230 V
1 Pha
se, 2
20–2
30 V
Pair
Sim
ulta
neou
s Twi
n Mu
lti
RZQ125KCTLT RZQ140KCTLT
Indoor unit
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
Indoor unit
Outdoor unitOutdoor unit
RZQ100KCTLTRZQ125LUYLT RZQ140LUYLTRZQ100LUYLT
OUTDOOR UNIT
CEILING MOUNTED CASSETTE TYPE
Round Flow
Pair
3 Pha
se, 2
20V/
380 V
NEW NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW NEW
NEW NEW
NEW NEW
NEW
NEW NEW
NEW NEW
NEWNEW NEW
NEW NEW
Non-inverter
Inverter Time
Running current
Starting current
Time
Running current
Curre
ntCu
rrent
At startup, full power is used to achieve the set temperature quickly. Then, the capacity is adjusted according to the outdoor temperature changes and subtle indoor load changes to achieve fine capacity control resulting in a more stable room temperature.
Inverter performs variable control of frequency, which determines air conditioner’s power performance.
Enhanced comfort with Inverter
34 new combinations added!
Small temp. differenceCools a room
in less time
Cooling operation
Inverter power controlNon-inverter type air conditioner
Time
Temp
Set temp
Non-inverter type air conditioners must be switched on and off repeatedly, causing large fluctuations of the room temperature.
Achieved higher COP
Comfortable
Energy saving
Comfortable
Comfortable currents of air are sent to every corner of the room.
Simultaneous Twin Multi OperationSimultaneous Twin Multi Operation
Energy saving
3 4
At startup, inverter raises frequency smoothly, eliminating the starting current spike.
COP is equal to capacity (kW) divided by power consumption (kW), and the larger the COP value, the higher the energy efficiency, enabling cooling and heating with less electricity and increasing the energy saving performance.
Note : *Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24.0°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
What is COP (Coefficient of Performance)
COP
1
2
3
4
FCQ50KVEARZR50LVVM
4.83
Cooli
ng*
FCQ140KVEARZR140LVVM
2.85
Cooli
ng*
FCQ125KVEARZR125LVVM
3.40
Cooli
ng*
FCQ100KVEARZR100LVVM
3.60
Cooli
ng*
FCQ71KVEARZR71LVVM
3.57
Cooli
ng*
FCQ60KVEARZR60LVVM
4.30
Cooli
ng*
CEILING MOUNTED CASSETTE TYPE
(1 Phase, 220–230 V)Round Flow
Full Lineup of Inverter SeriesFull Lineup of Inverter SeriesDaikin meets your needs with this full lineup of inverters for various types of indoor units and power supplies.
CEILING MOUNTED CASSETTE TYPERound Flow
CEILING MOUNTED CASSETTE TYPERound Flow
CEILING MOUNTED CASSETTE TYPERound Flow
CEILING SUSPENDED TYPE
WALL MOUNTED TYPE
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPEFLOOR STANDING TYPE
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
FLOOR STANDING TYPE
Pair
Pair
Pair
Twin
1 Pha
se, 2
20–2
30 V
3 Pha
se,
220 V
3 Pha
se,
380 V
CEILING MOUNTED CASSETTE TYPERound Flow
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
50 60 71 100 125 140
: New Lineup : Continuous
Refrigerant branch piping kit for Twin Multi operation
2 sets of Twin Multi
For example, four indoor units are judiciously spaced in this wide
single-floor restaurant to deliver comfortable currents of air to every corner of the room.
Airflow distribution
Creates uniform comfort throughout
the space
Comfort enhanced by Round Flow!
With uniform temperature distribution
Enhanced Comfort
Greater comfortImproved energy saving
• Condition after exposure to the smoke of 600 cigarettes in 1 m3 enclosed space.
Treated surface
Untreated surface
Grimy surface
Resists soiling
External panels are treated with a coating that repels dirt.
Mould-proof drain pan includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging.
Avoids uneven temperature and discomfort caused by drafts.
To prevent dirt sticking to the external panels, they have been coated with a surface treatment.
Because air flows out from corner outlets, comfort spreads more widely.
360° airflow Air movement is gentle with Round Flow
Condensation does not easily form on and dirt does not cling to non-flocking flaps. It is easy to clean.
Non-flocking flapsSilver ion anti-bacterial drain pan
Prevents mould and microorganisms growing out of the dust and moisture that adheres to the filters.
Filter has anti-mould and bactericidal treatment
Grime prevention and bactericidal coating: Make cleaning easier.
Adapts easily to the installation space.
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to close each unused outlet.
3-way flow L-shaped 2-way flow
Opposite 2-way flow
(E.g., installed in a corner)
(E.g., installed in a long room)
(E.g., installed near a wall)
(E.g., installed in middle of ceiling)
4-way flow also possible.
All-round flow
360° airflow can maintain comfort even if air discharge speed is lower.
Typical flow patterns There are a total of 23 flow patterns.
If you raise the set temperature by 1 to 1.5°C,and velocity is decreased by 25%, you still obtain the same feeling temperature and comfort.
Operation sound increases when using 2-way or 3-way flow.
• • • • • *1 *2 • *2 • • • *2 • • • • • • • • • • *2
CleanlinessComfort Work & Servicing Control features OthersOptionsFeatures
Accessory required for indoor unitOption
*1Applicable when wired remote controller is used*2For the outdoor units
*3Applicable when BRC1E62 is used*4Applicable when BRC1C61 is used
CEILING MOUNTED CASSETTE TYPE
FCQ50/60/71/100/125/140K
Swin
g pa
ttern
sel
ectio
n
Switc
habl
e fa
n sp
eed
(2 s
tep)
Aut
o sw
ing
Prog
ram
me
"Dry
"
Hig
h ce
iling
app
licat
ion
Nig
ht q
uiet
ope
ratio
n
Dra
in p
ump
mec
hani
sm
•
Silv
er io
n an
ti-ba
cter
ial
drai
n pa
n
•
Ant
i-bac
teria
l air
filte
r
Pre
char
ged
for
up to
30
m
Long
-life
filte
r
Filte
r sig
n
Cei
ling
soili
ng p
reve
ntio
n
Low
gas
pre
ssur
e de
tect
ion
Emer
genc
y op
erat
ion
Self-
diag
nosi
s fu
nctio
n
Ultr
a lo
ng-li
fe fi
lter
•
Hig
h-ef
ficie
ncy
filte
r
Fres
h ai
r int
ake
kit
Con
trol b
y 2
rem
ote
cont
rolle
rs
Aut
o-re
star
t
Gro
up c
ontro
l by
1 re
mot
e co
ntro
ller
Exte
rnal
com
man
d co
ntro
l
Cen
tral r
emot
e co
ntro
l
Inte
rlock
con
trol
•
DIII
-NET
com
mun
icat
ion
stan
dard
Ant
i cor
rosi
on tr
eate
dhe
at e
xcha
nger
s
Two
sele
ctab
le
tem
pera
ture
-sen
sors
Round Flow
Cassette air conditioner with 360° uniform airflow sets the standardCassette air conditioner with 360° uniform airflow sets the standard
Note: Remote controller cable not included. Cables must be procured locally.
BRC1E62
(Wired Remote Controller)Navigation Remote Controller
A signal receiver must be added to the indoor unit.
Wireless LCD remote controller
Wireless remote controller and signal receiver unit are sold as a set.
Signal receiver unit
(Installed type)
5 6
Remote controller
*3 *3 *3 *3 *4
Setp
oint
rang
e se
t
Wee
kly
sche
dule
tim
er
Setp
oint
aut
o re
set
Off
timer
(pro
gram
med
)
On/
Off
timer
BRC7F633F
Options required for specific operating environments
High-efficiency filterAvailable in two types: 65% and 90% colorimetry.
Using this kit, a duct can be fitted to increase the intake of outdoor air.
*Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating sound and may also influence temperature sending.
Fresh air intake kit
Even in smoky environments where the air conditioning is on most of the time, the ultra long-life filter only has to be changed once a year.
Ultra long-life filter Panel spacerUse when only minimal space is available between drop ceilings and ceiling slabs.
Sealing material of air discharge outletSealing material block air discharge openings not used in 2-way or 3-way blow.
Branch duct (direct-connection round duct)Outside
Note: Use of options will increase operating sound.
The units can be installed in the following different ways.
Note: Some ceiling constructions may hinder installation. Contact your Daikin Dealer before installing your unit.
Direct installation type
Flexible duct
T-joint pipe
Intake duct(procured locally)(duct length: 4 m max.)
Intake duct(procured locally)(duct length: 4 m max.)
Connectionchamber
Suctionchamber
Duct flange (with insulation material) Intake duct(procured locally)
Chamber type (with T-joint pipe and without fan)
Flexible duct(procured locally)T-joint pipe(procured locally)
Chamber type (without T-joint pipe and fan)
KDDP55X160KDDP55B160K KDDP55B160
Easier to maintain
With Ultra long-life filters (option), maintenance is not required in normal shops or offices for up to four years.
The condition of the drain pan anddrain water can be checked byremoving the drain plug andintake grille. Drain plug
Just open the
intake grille!
40mm
Panel spacer
A round duct can be attached without the need for a chamber.A flanged port for direct connection of a round duct is provided. An existing branch duct chamber can also be fitted (square slit hole).
Connectionchamber
Suctionchamber
Smoky atmosphere: annual filter change
Ordinary store or office: filter change every 4 years
*For dust concentration of 0.3 mg/m3 (Requires separately sold Air Cleaner.) 1 year (Approx. 5,000 hr) 15 hr/day x 28 day/month x 12 month/year
*For dust concentration of 0.15 mg/m3
4 years (Approx. 10,000 hr) 8 hr/day x 25 day/month x 4 years
Note:
Quick and easy to installJust 256 mm high. Installable in tight ceiling spaces (50K-71K)
Fine square panels Compact body and quiet operation
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room. **Wireless remote controller does not have a temperature-sensor.
Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Note: Air direction is set to the standard position when the unit is shipped from the factory. The position can be changed from the remote controller.
Panel size is same for all models, FCQ50-140K.It is easy to maintain a neat appearance when multiple units are installed.
Optimal comfort and convenience assured by air discharge modes
Both indoor unit and wired remote controller (option (BRC1D61,BRC1E62) ) contain temperature- sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians.
Two selectable temperature-sensors
Even in spaces with high ceilings, a comfortable airflow is carried down to the floor level.
Suitable for high ceilings
Operation starts when the preset time of the ON timer elapses and stops when the preset time of the OFF timer elapses.
On/Off timer
Indoor unit High Low
125K 44 34140K 44 36
100K 43 3271K 35 2860K 35 2850K 35 28
dB(A)
Same for all models
Air direction
Auto air direction control
Settable to 5 different levels between 15° and 60°
Settable to 5 different levels between 25° and 60°
Auto-swing between15° and 60°
Auto-swing between25° and 60°
Recommended for shops with light coloured ceilings that
must be kept spotless.Standard position to
prevent draft.
Standard setting Setting to prevent soiling of ceiling*
The air direction is set automatically to the memorised position of the previous air direction.
Desired situation
Auto-swing
5-levelsair directionsetting
*Closing of the corner discharge outlets is recommended.
Number of air discharge outlets used
4-wayflow
3-wayflow
2-wayflow
4-wayflow
3-wayflow
2-wayflow
3.1 m3.4 m4.0 m
All round flow
2.7 m3.0 m3.5 m
3.0 m3.3 m3.5 m
3.5 m3.8 m-
3.4 m3.9 m4.5 m
All round flow
3.2 m3.6 m4.2 m
3.6 m4.0 m4.2 m
4.2 m4.2 m-
StandardCeiling height High ceiling
High ceiling
Criteria for ceiling height and number of air discharge outlets
950 mm 950 mm
Note: Factory settings are for standard ceiling height and all-round flow. High ceiling settings (1) and (2) are set with the remote controller by field setting.
256 mm *1 266 mm *2
*1 298 mm high with 100K–140K*2 308 mm high with 100K–140K
All models can be installed without using lifter because of the light weight.
Connection to a centralised control system is available without option
Low gas pressure detection
Drain pump is equipped as standard accessory with 850 mm lift.
Transparent drain socket
Each corner of the unit has an Adjuster Pocket that lets you easily adjust the unit's suspended height.
Since the orientation of the intake grill can be adjusted after installing,the direction of the intake grill lines can be unified when multiple unitsare installed.
Note: If the wireless remote control option is installed, a light receptor unit is housed in one of the adjuster pockets.
Easy height adjustment
Installable in any direction
Because the drain socket is transparent, after the drain piping has been installed, it is easy to check if the drain come out through the socket.High setting provides maximum reach while low
setting minimises drafts.
Switchable fan speed: High/Low
175 mm
850 mm
100K–140K50K–71K
7 8
CEILING MOUNTED CASSETTE TYPE Round Flow
(Ceiling height is reference value)
10
* For dust concentration of 0.15 mg/m3
Non-flocking flap
Indoor unit High Low71CA 38 34
100CA 42 34125CA 44 37
Middle363841
140CA 46 3842
Drain pump kit (built inside main unit)
600 mm
Easy maintenance
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room. **Wireless remote controller does not have a temperature-sensor.
Oil resistant grille
Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification is not suitable for kitchens or other harsh environments.
Oil-resistant plastic is used for the air suction grille. This satisfies durability in restaurants and other similar environments.
Two time settings (2500 hrs and 1250 hrs) are available to match the installation environment. Maintenance time warning is displayed on the remote controller (filter sign).
Easy-clean, flat surfaces
Long-life filter lasts up to 6 months*
Comfortable
Both indoor unit and wired remote controller (option (BRC1E62) ) contain temperature- sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature requires initial setting by the installer.
Dehumidification is a microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature.
Two selectable temperature-sensors
Programme "Dry"
Installable on ceilings 4.3 m high
Flexible installation
*Water used in the test-run can now be drained from the air discharge opening rather than from the side as was formerly the case.
The unit fits more snugly into tight spaces. Flap neatly closes
when not in use.
Fresh white colour.
Drain pump kit (option) can be easily incorporatedDrain pipe connection can be done inside the unit. refrigerant and drain pipe outlets are at the same opening.
All wiring and internal servicing can be done from under the unit
Quiet operation
Installation flexibility for freedom of design
The latest stylish model
Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
dB(A)
Pipes more easily rigged
Low gas pressure detection
Condensation does not easily form on and dirt does not cling to non-flocking flap. It is easy to clean.
Non-flocking flap
The technology of the DC fan motor, wide sirocco fan, and large heat exchanger combine for greater airflow and quiet operation.
Sophisticated design
Connection to a centralised control system is available, without option.
Drain pump kit (option) includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging.
Auto swing (up and down) and louvers (left and right by hand) bring comfort to the room
Switchable fan speed: High/Middle/Low and Auto
30 mm or more
30 mm or more
High/Middle/Low : 46/42/38 db(A)
("Auto" is applicable when BRC1E62 is used.)
Louver manually adjusts for straight or wide angle airflow
Accessory required for indoor unitOption
Note: Remote controller cable not included. Cables must be procured locally.
BRC1E62
(Wired Remote Controller)Navigation Remote Controller
A signal receiver must be added to the indoor unit.
Wireless LCD remote controller
Wireless remote controller and signal receiver unit are sold as a set.
BRC7GA56
9
CEILING SUSPENDED TYPE
FHQ71/100/125/140CA
Comfortable airflow travels throughout the roomComfortable airflow travels throughout the room
NEW
Signal receiver unit (Installed type)
CleanlinessComfort Work & Servicing Control features OthersOptionsFeatures
• • • *1 • • • • • • • • • *3*3*2 *5
*1Installable on max. 4.3 m high ceiling *2Applicable when wired remote controller is used*3For the outdoor units*4Applicable when BRC1E62 is used*5Option
Pre
char
ged
for
up to
30
m
•
Ant
i-bac
teria
l air
filte
r
Filte
r sig
n
*3
Low
gas
pre
ssur
e de
tect
ion
Emer
genc
y op
erat
ion
Self-
diag
nosi
s fu
nctio
n
Con
trol b
y 2
rem
ote
cont
rolle
rs
Aut
o-re
star
t
Gro
up c
ontro
l by
1 re
mot
e co
ntro
ller
Exte
rnal
com
man
d co
ntro
l
Cen
tral r
emot
e co
ntro
l
Ant
i cor
rosi
on tr
eate
dhe
at e
xcha
nger
s
•
DIII
-NET
com
mun
icat
ion
stan
dard
•
Fres
h ai
r int
ake
kit
Inte
rlock
con
trol
Dra
in p
ump
mec
hani
sm
Switc
habl
e fa
n sp
eed
(3 s
tep)
Aut
o sw
ing
Prog
ram
me
"Dry
"
Hig
h ce
iling
app
licat
ion
Two
sele
ctab
le
tem
pera
ture
-sen
sors
Remote controller
*4 *4 *4 *4
Setp
oint
rang
e se
t
Wee
kly
sche
dule
tim
er
Setp
oint
aut
o re
set
*3
Nig
ht q
uiet
ope
ratio
n
Off
timer
(pro
gram
med
)
12
Comfortable
Maintenance possible from the front of the unitAll maintenance tasks can be carried out via front access. During service work, attachment and detachment of parts is easier.
Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature.
Programme "Dry"
Two selectable temperature-sensors
Comfort even on the far side of the roomTo carry air to the far side of long rooms, extra-high airflow adds 10% more fan speed the "high" setting. Air discharge strength is selected from the remote controller by field setting.
Easy cleaning
6-direction piping offers greater installation flexibility.
Compact & Sophisticated design
FAQ100
Flaps neatly close when not in use
Easy installing and servicing
Drain pump kit is available as option.
Removable and washable grille
Connection to a centralised control system is available without option
Drain pump kit can be installed on either left and right side of the air conditioner.
Height of drain up
Drain pump kit Indoor unit
Installs onto side of unit.
1,000 mm
Refrigerant piping
1,200mm
340mm
370mm shorter
9kg lighterHeight
FAQ100BV360mm
Width 1,570mm
Weight 26kg
FAQ100C340mm
1,200mm
17kg
Depth 200mm 240mm
Auto airflow rate (When BRC1E62 is used)
Switchable fan speed: High/Middle/LowCondensation does not easily form on and dirt does not cling to non-flocking flaps. It is easy to clean.
Non-flocking flaps
Flat panel, easy to wipe dust off
An air discharge modes ensure comfortable air distribution across the entire room
Auto swing (up and down) and wide-angle louvers (left and right by hand) facilitate even room temperature
Auto-swing 5-level air direction setting
Gettable to 5 different levels
Soft material louver bends airflow over a wider area
Wide-angle louvers (by hand)
11
WALL MOUNTED TYPE
FAQ71C
FAQ100C
FAQ71/100C
Compact design and easy installationCompact design and easy installation
• • •• *4 • *3 • • • • • • • • • *3
CleanlinessComfort Remote controller Work & Servicing Control features Others
Features
*2
*1Applicable when BRC1E62 is used *2Applicable when wired remote controller is used*3For the outdoor units
*4Applicable when BRC1C61 is used*5Option
Switc
habl
e fa
n sp
eed
(3 s
tep)
*1
Aut
o ai
rflow
rate
Aut
o sw
ing
Prog
ram
me
"Dry
"
Hig
h fa
n sp
eed
mod
e
On/
Off
timer
*1
Off
timer
(pro
gram
med
)
*1
Wee
kly
sche
dule
tim
er
*1
Setp
oint
rang
e se
t
*1*3
Setp
oint
aut
o re
set
Pre
char
ged
for
up to
30
m
Mou
ld-p
roof
air
filte
r
Filte
r sig
n
Emer
genc
y op
erat
ion
Self-
diag
nosi
s fu
nctio
n
Con
trol b
y 2
rem
ote
cont
rolle
rs
Aut
o-re
star
t
Ant
i cor
rosi
on tr
eate
dhe
at e
xcha
nger
s
•
DIII
-NET
com
mun
icat
ion
stan
dard
*5
Dra
in p
ump
mec
hani
sm
*3
Low
gas
pre
ssur
e de
tect
ion
Gro
up c
ontro
l by
1 re
mot
e co
ntro
ller
Exte
rnal
com
man
d co
ntro
l
Cen
tral r
emot
e co
ntro
l
Inte
rlock
con
trol
Two
sele
ctab
le
tem
pera
ture
-sen
sors
Nig
ht q
uiet
ope
ratio
nNEW
Right pipe
Left pipe
Back-left pipe
Back-right pipe
Bottom-left pipe
Bottom-right pipe
Accessory required for indoor unitOption
Note: Remote controller cable not included. Cables must be procured locally.
BRC1E62
(Wired Remote Controller)Navigation Remote Controller
A signal receiver must be added to the indoor unit.
Wireless LCD remote controller
Wireless remote controller and signal receiver unit are sold as a set.
BRC7EB519
Signal receiver unit (Installed type)
Increased freedom of design thanks to variable control over external static pressure
Comfort airflow achieved in accordance with conditions such as duct length.Using a DC fan motor, the external static pressure can be controlled within a range of 50 Pa to 200 Pa.
Thin, lightweight indoor unit makes delivery and installation easy.
With a height of only 300 mm, installation is possible even in buildings with narrow ceiling spaces.
3001,000
36
1,400700
HeightIndoor unit
WidthDepth
46Machine weight
50/60/71DA 100DA 125/140DA
Freely control external static pressure
50 Pa 200 PaSet to high static pressure for
advanced needs such as when using dampers and long ducts.
Set to low static pressure when ducts
are short.
Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
Ventilation grille
Door-installedventilation grille
Ventilation grille
Wall-installedventilation grille
Under-door cutout
Under-door cutoutWhen air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be installed for each room or one of the indicated ventilation grilles should be installed on the partitioning wall or under the door between the rooms.
Ventilates air through the partitioning wall. (See right)
Partitioning wall
Note: The under-door cutout method should be used only when there is a small volume of airflow.
(mm)
(mm)
(mm)
(kg)
Quiet operation
When testing standard integrated ceiling units that employ duct work, much time used to be required to adjust airflow to the right level. Thanks to the ability provided by Daikin to automatically perform this troublesome adjustment using a remote controller, this step is now quick and easy. (Adjust by H tap .)1. Adjust to approximately ±10% of the rated H tap airflow. 2. Once actual operation has begun, adjustment of the rated airflow is not possible.
Reduced installation timeUse remote controller to adjust airflow
Mould-proof drain pan includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging.
Silver ion anti-bacterial drain pan
Maintenance is easy because the drain pan can be removed.
Easy maintenance
Clean
Both indoor unit and wired remote controller (option) contain temperature- sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control.This feature requires initial setting by the installer. *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.
**Wireless remote controller does not have a temperature-sensor.
Two selectable temperature-sensorsComfortable
dB(A)100DA 125/140DA
HighLow
38 4033 36
50/60/71DA3732
300mm
Easier connection with the centralised control system
Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Accessory required for indoor unitOption
Note: Remote controller cable not included. Cables must be procured locally.
BRC1E62
(Wired Remote Controller)Navigation Remote Controller
A signal receiver must be added to the indoor unit.
Wireless LCD remote controller
Wireless remote controller and signal receiver unit are sold as a set.
BRC4C64
Control featuresWork & ServicingComfort Cleanliness OthersOption
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
Features
*1Applicable when wired remote controller is used*2For the outdoor units*3Applicable when BRC1E62 is used*4Applicable when BRC1C61 is used*5Option
• *2• *1 *2 *2• • • • • • • *2• •
Switc
habl
e fa
n sp
eed
(2 s
tep)
Prog
ram
me
"Dry
"
Nig
ht q
uiet
ope
ratio
n
*5
Ant
i-bac
teria
l air
filte
r
•
Silv
er io
n an
ti-ba
cter
ial
drai
n pa
n
Pre
char
ged
for
up to
30
m
Filte
r sig
n
Self-
diag
nosi
s fu
nctio
n
•
Emer
genc
y op
erat
ion
Low
gas
pre
ssur
e de
tect
ion
Ant
i cor
rosi
on tr
eate
dhe
at e
xcha
nger
s
Hig
h ef
ficie
ncy
filte
r
Con
trol b
y 2
rem
ote
cont
rolle
rs
Aut
o-re
star
t
Gro
up c
ontro
l by
1 re
mot
e co
ntro
ller
Exte
rnal
com
man
d co
ntro
l
Cen
tral r
emot
e co
ntro
l
Inte
rlock
con
trol
•
DIII
-NET
com
mun
icat
ion
stan
dard
Two
sele
ctab
le
tem
pera
ture
-sen
sors
FBQ50/60/71/100/125/140DA
Signal receiver unit
(Separate type)
Enhance comfort using cleverly placed ductsEnhance comfort using cleverly placed ducts
*5
Long
-life
filte
r
13 14
Remote controller
*3 *3 *3 *3 *4
Setp
oint
rang
e se
t
Wee
kly
sche
dule
tim
er
Setp
oint
aut
o re
set
Off
timer
(pro
gram
med
)
On/
Off
timer
Floor Standing Type
New airflow control for more comfortNew airflow control for more comfort
15 16
Quiet operation
Quick and easy installation and maintenance
Lightweight indoor unit
Easier connection with the centralised control system.
Enables smooth transport and installation of the indoor unit.
The grill will not open even upon impact.
Long-life filter lasts about 1year * maintenance not requiredEnergy saving
A DC fan motor improves efficiency.* For dust concentration of 0.15 mg/ m3
Employs a safety lock function of suction grill.
Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Long
-life
filte
r
100C 125C 140CHigh
Indoor unit 50/60/71C50 51 5343
Middle 47 48 5141Low 44 46 4838
dB(A)
39 47100C 125C 140C
WeightIndoor unit 50/60/71C
(kg)
FVQ50/60/71/100/125/140CNEW
• • •*2 *4 • *3 •• • • • • • • • • *3
CleanlinessComfort Remote controller Work & Servicing Control features Others
Features
•*1Applicable when BRC1E62 is used*2Applicable for FVQ50-100 *3For the outdoor units
*4Applicable when BRC1C61 is used
Switc
habl
e fa
n sp
eed
(3 s
tep)
•
Inde
pend
ent u
p-an
d-do
wn
airfl
ow
*1
Aut
o ai
rflow
rate
Aut
o sw
ing
Prog
ram
me
"Dry
"
Hig
h fa
n sp
eed
mod
e
On/
Off
timer
*1
Off
timer
(pro
gram
med
)
*1
Wee
kly
sche
dule
tim
er
*1
Setp
oint
rang
e se
t
*1*3
Setp
oint
aut
o re
set
Pre
char
ged
for
up to
30
m
Ant
i-bac
teria
l air
filte
r
Filte
r sig
n
Emer
genc
y op
erat
ion
Self-
diag
nosi
s fu
nctio
n
Con
trol b
y 2
rem
ote
cont
rolle
rs
Aut
o-re
star
t
Ant
i cor
rosi
on tr
eate
dhe
at e
xcha
nger
s
•
DIII
-NET
com
mun
icat
ion
stan
dard
*3
Low
gas
pre
ssur
e de
tect
ion
Gro
up c
ontro
l by
1 re
mot
e co
ntro
ller
Exte
rnal
com
man
d co
ntro
l
Cen
tral r
emot
e co
ntro
l
Inte
rlock
con
trol
Two
sele
ctab
le
tem
pera
ture
-sen
sors
Nig
ht q
uiet
ope
ratio
n
Comfortable fan speed control
To carry airflow to the far side of the room, airflow rate can be increased 5% or 10% depending on the installation condition or customer's request. (Field setting by remote controller.)
High fan speed mode
Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature.
Programme "Dry"
(applicable for FVQ50-100)
Airflow rate is automatically controlled in accordance with the difference between room temperature and set temperature.
Auto airflow rate is selectable.
Example applications
When coolingTurning louvers and upward and leaving and horizontal will reduce uneven room temperature.
New comfortable airflow control1) Left and right directions
2) Up and down directions Independent up-and-down airflow directions facilitate even room temperature and help save energy.
New unit
(by remote controller)
(by hand)
Freely select both up and down airflow direction with 8-louver (horizontal blade) operation.
Upper louver (1)Upper interlocking louvers (4)Lower interlocking louvers (2)Lower louver (1)
Each set of louvers to can be independently adjusted. (Manual adjustment)
Auto swing direction is selectable from 3 patterns to suit the layout of the room.Pattern 1 Wide swing toward the front
When installed in the center of a wall. When installed in the corner of a room.
Pattern 2 Swing on the left side Pattern 3 Swing on the right side
Switchable fan speed: High/Middle/Low and Auto("Auto" is applicable when BRC1E62 is used.)
Accessory required for indoor unit
Option
BRC1E62 can be
incorporated into the
main unit.
Note: Remote controller cable not included. Cables must be procured locally.
BRC1E62
(Wired Remote Controller)
Navigation Remote Controller
These two features work to reduce noise. Guides are added to the bell mouth intake to reduce turbulence in the airflow generated by fan suction. The Aero Spiral Fan features fan blades with the bent blade edges, further reducing turbulence.
Smooth Air Inlet Bell Mouth and Aero Spiral Fan
Escaping eddies are sucked in by the bent blade edges, reducing overall turbulence.
The high efficiency compressor to achieve a high COP
2
1
DC fan motorEfficiency improved in all areas compared to AC motors, especially at low speeds.
Sine wave DC inverter >> Smooth sine wave DC inverter Use of an optimised sine wave smoothes motor rotation, further improving operating efficiency.
Sucked gas is compressed in the scrolling part before the heated motor, so that the machine compress the non expanded gas, resulting in high efficiency compression.
>> The structural scrollEnergy savings is realised, eliminating the friction and the leakage of refrigerant gas.
>> Swing compressor
Compressor equiped with Reluctance DC motor
3DC fan motor structure
With the bent blade edge
Without the bent blade edge
ReluctanceDC motor
Scroll section
Suction
Discharge Motor section
RZR50/60/71/100LV
Technology for energy efficiency
Swing bushing Refrigerant gas
Piston by incorporated blade and roller.
500 30 60 90 120
60
70
80
90
Small load Large loadLow capacity High capacity
Reluctance DC Motor
Conventional DC motor
More than 20%
AC motor
Rotational speed (rps)
Moto
r effi
cienc
y (%
)
Daikin DC Inverter models are equipped with the Reluctance DC motor for compressor. The Reluctance DC motor uses 2 different types of torque, neodymium magnet*1 and reluctance torque*2. This motor can save energy because it generates more power with a smaller electric power than an AC or conventional DC motor.
*1. A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet.
*2. The torque created by the change in power between the iron and magnet parts.
Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory.
RZR125/140LV, RZQ100/125/140KC, RZQ100/125/140LU
(RZR/RZQ100-140 only)
3
1
2
OUTDOOR UNIT
New Compact Outdoor unit
Easy installation and maintenancePre charged for up to 30 metres
Long piping length
4di rection piping offers greaterlayout freedom
Separation available
If refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging.
A pump-down switch is provided to make it easier to collect refrigerant if the unit is to be moved or layout modified.
Facilitates pump down (Refrigerant recovery function)
Effective gas monitoring reduces the labor required for operation, maintenance, and repairs.
Low gas pressure detection function
The maximum capacity is maintained within a set level of power consumption, which makes it possible to keep comfort and effective demand control.
As the bottom frame is subject to corrosion, corrosion-proof galvarium steel plate is adopted to enhance the durability.Heat exchange fins provided with anti-corrosion treatment
Durability
Through use of a Vcut propeller fan that imitates the efficiency of the swan, a migratory bird, airflow becomes smooth and loss is reduced.
Energy saving
ConstructionNon-treated fin
Anti corrosion treated heat exchangers
Aluminium
AluminiumCorrosion resistantacrylic resin
Hydrophilic film
Allowed refrigerant piping length and level difference
Note : 1Additional refrigerant charging is required if the refrigerant pipe is longer than the length.
Demand Control Function
8:00 12:00 16:00 20:00
Pow
er
cons
umpt
ion
Time
Limitation
* Required for KRP58M51 (Option)
Max. length
Max. leveldifference
Pre charged1
RZR50140LV RZQ100 140KC/LU
30 m
50 m(Equivalent length 70m)
70 m(Equivalent length 90m)
30 m
The outer panel for the piping connection part of the front, right side and backside can be removed and is easier for post-installation piping work.
*Pump down function is available for pre charged refrigerant amount.
(RZR/RZQ100-140 only)
Night time quiet operation functionThe Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime, and normal operation will resume 10 hours after that.
49
50
RZR100LVRZQ100/125/140KC
RZQ100LU
48RZR50/60/71LV
Sound level1 (dB(A))
RZR125LVRZQ125/140LU
50
45
45
44
46RZR140LV
Rated2 Night Quiet Mode
Note : 1Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 2Value when cooling. Value will differ when heating.
Note : 3In case of RZQ series, period selectable from 22 8:00, 22 6:00, and 20 8:00. 4In case of RZR100
Reducing noise will reduce capacity slightly.
Comparison of outdoor unitsConventional
(RZQ71KC)NEW
(RZR71LV)
Height 770 mm 595 mmWeight 68 kg
Height 1,170 mmWeight 98 kg
43 kg
Conventional(RZQ100KC)
NEW(RZR100LV)
990 mm78 kg
595mm
990mm
Reduced installation work thanks to light, compact outdoor unit.
Compact and lightweight
RZR71LVVMRZQ71KCVLT
RZR100LVVMRZQ100KCVLT
RZR50LVVMRZR60LVVMRZR71LVVM RZR100LVVM
RZQ100LUYLTRZQ125LUYLTRZQ140LUYLT
RZQ100KCTLTRZQ125KCTLTRZQ140KCTLT
RZR125LVVMRZR140LVVM
Φ550V cut propeller fan
Imitating the performance of the swan
(RZR/RZQ100-140 only)
17 18
100
50
0
8:00
Peak in outdoor temperature
8 hours
Rated
10 hours
Quiet modeQuiet mode
12:00 16:00 20:00
22:003 8:003
0:00 4:00 8:00
45
49
Capa
city (
%)
Load
(%)
Oper
ation
So
und4 (d
B(A)
)
Reduced by175 mm
Reduced by25 kg
Reduced by180 mm
Reduced by20 kg
Signal receiver unit (For ceiling mounted cassette type)
LCD REMOTE CONTROLLER Optional accessory
Enables temperature sensing closer to target area for improved comfort. (When using remote control from another room, temperature-sensor in indoor unit's air inlet must be selected.)
Facilitates maintenance and repairAll initial settings can be set from the remote controller. After interior construction is complete, ceiling mounted cassette type can be remotely set without having to use stepladder access for manual setting.Setting contents: High ceiling use, air direction, filter type, address for centralised control (group control address is set automatically).
Remote controller is equipped with model name and failure display functions. This facilitates service in the unlikely event of a malfunction.
SkyAir shares common control with Heat Reclaim Ventilator and the other Daikin air-conditioning units, thus simplifying interlocking operations.
Easily adaptable to large-scale, high-function, centralised remote control systems.Installing and connecting control wiring between SkyAir and other Daikin air-conditioning equipment is easy.
LCD panel shows operating status in letters, numbers, and motion.Airflow / swing display Displays auto-swing operating status and setting position of air discharge angle.
Preset temperature / operation mode display Displays preset room temperature and operating status (fan, dry, cool).
Programming time display Operation start and stop time can be set for individual timers up to 72 hours. The LCD also shows when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.
Self-diagnosis function Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.
Indoor units applicable for the remote controllerSignal receiver unit is contained inside decoration panel or indoor unit
CEILING MOUNTED CASSETTE TYPE
CEILING SUSPENDED TYPE
BRC7F633F
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE BRC4C64
BRC7GA56WALL MOUNTED TYPE BRC7EB519
LCD wireless remote controller
Note: The signal receiver unit shown in the photograph is for mounting inside the decoration panel of the ceiling mounted cassette type.
Wireless remote controller
Light receptor mounted type
BRC7F633F
The wireless remote controller is supplied in a set with a signal receiver.Shape of signal receiver unit differs according to the indoor unit.
The rubber switch and the oil-resistant plastic casing are adopted for durability.Only 17 mm thick. Can be installed either recessed or exposed.
Easy to read because of large LCD screen.Wired LCD remote controller
BRC1C61
Wired remote controller has built-in temperature-sensor (Applies to wired remote controllers (BRC1C61/1E62))
(Applies to wired remote controller (BRC1E62))
19 20
Clear Display
Navigation Remote Controller(Wired Remote Controller BRC1E62)
- 5 actions per day can be scheduled for each day of the week.- The holiday function will disable schedule timer for the days that have been set as holiday.- 3 independent schedules can be set. (e.g. summer, winter, mid-season)
Display is available in 11 languages.
Dot matrix display Backlight display
ConvenienceWeekly schedule Multilingual display
Easy-to-read LCD remote controller allows various system control configurations and can control multiple indoor units. Remote controller options are shown on the page introducing each indoor unit model.
NEW
(English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish, and Polish).NEW
A combination of fine dots enables various icons.Large text display is easy to see.
This simple, modern designed remote controller with fresh white colour matches your interior design. Operation is much easier and smoother, just follow the indications on the navigation remote controller.
Energy savingNEW
- Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts.- Period can be preset from 30 to 180 minutes in10-minute increments.
Off timer (programmed)
Setpoint range setNEW Setpoint auto reset
Restaurant sampleRestaurant opened
Temperature is set to 27ºC
27°C
- Saves energy by limiting the min. and max. set temperature.
- Avoids excessive heating or cooling.
- This function is convenient when the remote controller is installed at a place where any number of people may operate it.
- Even if the set temperature is changed, it returns to the preset temperature after apreset period of time.
- Period selectable from 30min/60min/90min/120min.
Full tables at lunchtimeThen is lowered to 24ºC for crowded room
24°C
After 30 minutes*Automatically returns to preset temperature (27ºC)
*Setting possible for after 30, 60, 90, and 120 minutes.
Returns to27°C
automatically
LCD REMOTE CONTROLLER
Central remote controller
Easily adaptable to large-scale, high-function, centralised remote control system.
Centralised control, with setting as simple as it is with a standardremote controller, of up to 64 groups (1,024 indoor units) is possible.
DCS302CA61 (Option)
With its high functionality, the full colour “all-in-one” graphic controller facilitates management of SkyAir System in a variety of ways.
DCS601C51 (Option)Unified on/off controller
Centralised control of on/off by group or all at once for up to 256 indoor units.
DCS301BA61 (Option)
Schedule timer
Unified control of weekly schedule for up to 1,024 indoor units.
DST301BA61 (Option)
Schedule timer sets on/off time in 1 minute units to be executed twice a day for a week at a time.
Simple system provides a diverse assortment of control modes.
Control by 1remote controller
Control pattern Wired remote controller Wireless remote controller
Control by 2remote controllers
Group control
Control by external command
Centralised remotecontrol
Interlock controlwith Heat Reclaim
Ventilator
(Basic system)
Link by remote controller group control.
Zone link control by centralised control.
For control from 2 locations such as in room and control room, exits, etc.
For simultaneous control of up to 16 indoor units.
Centralised control of up to 64 indoor groups from remote locationup to 1 kilometer away.
Control by 1 wireless remote controller and 1 wired remotecontroller (See note 2, 3)Signal receiver unit installed on indoor unit
Signal receiver unit installed on indoor unit
Heat Reclaim Ventilator for indoor units within a zone are operated by interlocking Can also be operated independently by remote controller.
Central remote controller (option)
Heat ReclaimVentilator
Can be operated simultaneously or independently by remote controller (set by ventilation mode)
Heat ReclaimVentilator
Non-polar, double-core (max. wiring length 500 m)
Connects 2 wired remote controllers (See note 1)
Automatic address setting function Automatic address setting functionSignal receiver unit installed on 1 indoor unit
Optional wiring adaptor for electrical appendices is necessary
Can be operated simultaneously by remote controller (set by ventilation mode)
Heat ReclaimVentilator
Heat Reclaim Ventilator for indoor units within a zone are operated by interlocking
Central remote controller (option)
Heat ReclaimVentilator
Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room.
Optional wiring adaptor for electrical appendices is necessary
Note: 1BRC1E62 can connect to BRC1E62 only. 2It is not possible to use two wireless remote controllers. 3BRC1E62 cannot connect to wireless remote controller.
Central remote controller (option) Central remote controller (option)
Abundance of functions that provide comfortable air-conditioning in stores and offices. Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.
21 22
Cleanliness
Mould-proof drain pan includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging.
Silver ion anti-bacterial drain panThe Air filter has a anti-bacterial treatment to help prevent the growth of bacteria and mould on it.
Anti-bacterial air filter
Sanitary filter has mould-resistant treatment.Mould-proof air filter
Note: Wireless remote controllers have no temperature-sensor.
Use the temperature-sensor in the indoor unit when controlling air conditioning from another room.
Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Useful for reducing uncomfortable humidity without uncomfortable cooling of the room.
Delivers comfortable air-conditioning to all areas, near to and far from the air-conditioner.
High setting provides maximum reach while low setting minimises drafts.
Auto-swing Programme "Dry"
Switchable fan speed
(1) Air direction in standard setting
(2) Air direction in ceilingsoiling prevention setting
(standard, ceiling soiling prevention)
Note:When units are installed on high ceilings, depending on the model, various restrictions concerning maximum height, air discharge direction, and choice of options may apply.
You can freely set 2 air discharge setting by remote controller.
Swing pattern selectionDelivers air-conditioning comfort all the way down to the floor in air-conditioning zones with high ceilings.
High-ceiling application
Airflow rate is automatically controlled in accordance with the difference between room temperature and set temperature.
Auto airflow rate
Two selectable temperature-sensors
Comfort
The air flow direction can be fixed at your desited angle by the remote controller.
Temperature-sensors are included in the indoor unit and optional wired remote controller. Temperature sensing closer to target area is possible to further increase the comfort level.
Remote Controller
Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts.
Off timer (programmed)
Operation starts when the preset time of the ON timer elapses and stops when the preset time of the OFF timer elapses.
On/Off timer
Up to five operation ON/OFF settings can be programmed per day for each day of the week. Not only can the time be set for the operation ON setting, but also the temperature.
Weekly schedule timer
Even if the set temperature is changed, it returns to the preset temperature after a preset period of time.
Saves energy by limiting the minimum and maximum set temperatures. Avoids excessive heating and cooling.
Setpoint auto reset
Setpoint range set
Applicable for wall mounted type
You can increase fan speed approximately 10% higher than the "high" setting.
High fan speed modeThe Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime, and normal operation will resume 10 hours after that.
Night quiet operation
Independently adjust (manually) the eight horizontal blade louvers in both up and down directions to achieve an airflow that reduces uneven room temperature.
Independent up-and-down airflow
If there is a malfunction elsewhere in the system, the fan or compressor can still be operated.
Insufficient gas charging is normally hard to detect. During post-installation trials and regular inspection procedures, the refrigerant level is monitored by microprocessor to maintain proper gas pressure. Reliability is assured and maintenance and inspection can be carried out more quickly.
You can turn up to 16 indoor units on/off with a single remote controller. (When using connected indoor units, the settings must all be the same and on/off will be simultaneous.)
Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.
Emergency operation
Low gas pressure detection
Group control by 1 remote controller
Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room.
External command control
Optional central remote controller enables centralised control of up to 1024 indoor units (64 groups) from up to 1 kilometer away.
Central remote control
Enables interlocking control with external equipment such as Heat Reclaim Ventilator.
Interlock control
The operating parameters of indoor and outdoor units, and sensor data at critical locations throughout the system, are constantly monitored using a microcomputer. To facilitate quick response in the event of a malfunction, a message appears on the LCD of the remote controller and an LED on the unit illuminates.
Self diagnosis function
Two types are available: 65% and 90% colorimetry. High-efficiency filter unit
You can provide air-conditioning with fresh air from outside. Convenient for places where a ventilation fan cannot be installed.
Fresh-air intake kit
Work and Servicing
Control features
Options
Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping.
Maintenance is not required for one year (two years when a ceiling mounted cassette type is used).
If refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging.
The filter sign warns you when it is time to clean the filter. *When using a wired remote controller the sign is displayed in the LCD. When using a wireless remote controller the filter sign lamp illuminates on the signal receiver unit.
Drain pump mechanism
Long-life filter
Pre charged for up to 30 metres
Filter sign
Daikin's innovative air discharge mechanism keeps airflow away from the ceiling. Ceiling cleaning is less frequently required.
Ceiling soiling prevention function
If there is a power outage while the equipment is operating, operations will restart in the same mode as before the power cut when electricity is restored.
Ultra long-life filter
Auto-restart
Using 2 remote controllers you can operate the equipment locally or from a remote location.Note: When a wireless remote controller is used, remote control by two remote controllers is not possible.
Control by 2 remote controllers
Requires no maintenance for about 4 years* (10,000h) in stores and offices.*For dust concentration of 0.15 mg/m3
*Required for KRP58M51 (Option)
*Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating noise and may also influence temperature sending.
Note:
Others
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated Anti corrosion treated heat exchangers (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.In high corrosive areas, regular maintenance needs to be carried out.
Anti corrosion treated heat exchangers
Standardly equipped interface enables connection to centralised control system without need of an adaptor.
DIII-NET communication standard
SPECIFICATIONS
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).2Capacities are net, including a deduction for cooling for indoor fan motor heat.3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
dB(A)
CEILING MOUNTED CASSETTE TYPE
Cooling capacity1,2
Rated (Min. - Max.) kW
°CDBCoolingCertified Operation range
Sound level3
°CWBCoolingCertified Operation range
Motor outputCompressor
ModelName
Indoor unitOutdoor unitOutdoor unit
Dimensions(HXWXD)
Colour
mmmm
dB(A)
kWRefrigerant charge (R-410A) kg
dB(A)
Dimensions (HXWXD) mmMachine weight kg
Unit
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Decoration panel
UnitDecoration panel
Machine weight kg
kgUnitDecoration panel
Airflow rate (H/L) m3/mincfm
Outdoorunit
Colour
mm
Heat insulation
Max. interunit piping length mmMax. installation level difference
Power supply
Type
Cooling
Sound level (H/L)3
Indoorunit
71FCQ71KVEARZR71LVVM
Hermetically sealed swing type1.76
7.1 (3.2-8.0)
100FCQ100KVEARZR100LVVM
43/32
49
990X940X32078
2.032.7
(Charged for 30 m)
32/20
10.0 (5.0-11.2)
125FCQ125KVEARZR125LVVM
44/34
o/ 9.5o/ 15.9
50
1,170X900X32097
24
298X840X840 256X840X84050X950X950
5.5
----------
1 Phase, 220–230 V, 60 Hz
30
Ivory white
Fresh white
Both liquid and gas piping
50 (Equivalent length 70)
Hermetically sealed scroll type
o/ 26.0 (Hole)
2.43.15
(Charged for 30 m)
VP25 (I.Do/ 25XO.Do/ 32)
33/22.51,130/706 1,165/794
12.5 (5.7-14.0)
140FCQ140KVEARZR140LVVM
44/36
21 to 46
14 to 25
3.1
14.0 (6.2-15.4)
kWPower consumption Cooling
125FCQ60KVEAx2RZR125LVVM
35/28
2.4
21/13.5741/477
12.5 (5.7-14.0)
140FCQ71KVEAx2RZR140LVVM
3.1
14.0 (6.2-15.4)
1.99 2.78 3.68 4.91 3.68 4.91
Night quiet mode
dB(A)Night quiet mode
50FCQ50KVEARZR50LVVM
1.12
5.0 (2.3-5.6)
60FCQ60KVEARZR60LVVM
35/28
48
595X845X30043
21 21
256X840X840
1.351.6
(Charged for 30 m)
21/13.5741/477
6.0 (2.6-6.3)
1.03 1.40W/WCOP 3.57 3.60 3.40 2.85 3.40 2.854.87 4.30
45 46464544
Cooling capacity1,2
Rated (Min. - Max.) kW
°CDBCoolingCertified Operation range
Sound level3
°CWBCoolingCertified Operation range
Motor outputCompressor
ModelName
Indoor unitOutdoor unitOutdoor unit
Dimensions(HXWXD)
Colour
mmmm
dB(A)
kWRefrigerant charge (R-410A) kg
dB(A)
Dimensions (HXWXD) mmMachine weight kg
Unit
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Decoration panel
UnitDecoration panel
Machine weight kg
kgUnitDecoration panel
Airflow rate (H/L) m3/mincfm
Outdoorunit
Colour
mm
Heat insulation
Max. interunit piping length mmMax. installation level difference
Power supply
Type
Cooling
Sound level (H/L)3
Indoorunit
140FCQ140KAVLTRZQ140KCTLT
Hermetically sealed scroll type
13.3 (6.2–15.8)
100FCQ100KVLT
RZQ100LUYLT
43/32
101
32/20
10.0 (5.0–11.4)
125FCQ125KAVLTRZQ125LUYLT
44/34
o/ 9.5o/ 15.9
50
50X950X950
5.5
----------
3 Phase, 220V, 60Hz 3 Phase, 380V, 60Hz
30
Ivory white
Fresh white
Both liquid and gas piping
70 (Equivalent length 90 m)o/ 26.0 (Hole)
VP25 (I.Do/ 25XO.Do/ 32)
33/22.51,130/706 1,165/794
12.5 (6.0–14.3)
140FCQ140KAVLTRZQ140LUYLT
44/36
-5 to 50
14 to 25
13.1 (6.2–15.8)
kWPower consumption Cooling
100FCQ100KVLT
RZQ100KCTLT
10.0 (5.0–11.4)
125FCQ125KAVLTRZQ125KCTLT
43/32 44/34 44/36
4945
1,170X900X32099
24
298X840X840
3.7 (Charged for 30 m)
32/201,130/706
33/22.51,165/794
12.5 (6.0–14.3)
W/WCOP
23 24
2.41.9 2.9 2.41.8
3.47 3.912.77 3.51 3.852.773.603.61 3.40 3.563.61 3.40
2.9
CEILING SUSPENDED TYPE
Refrigerant charge (R-410A)
SPECIFICATIONS
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).2Capacities are net, including a deduction for cooling for indoor fan motor heat.3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
VP20 (I.Do/ 20XO.Do/ 26)
Hermetically sealed swing type
30
100FHQ100CAVEBRZR100LVVM
42/38/34
o/ 9.5o/ 15.9
990X940X32078
49
28/24/20988/847/706
10.0 (5.0-11.2)
o/ 26.0 (Hole)
2.032.7
(Charged for 30 m)
3.03
38/36/34235X1,270X690
595X845X30043
32
48
20.5/17/14724/600/494
1.6 (Charged for 30 m)
1 Phase, 220–240 V, 50 Hz/220–230 V, 60 Hz
Ivory white °CWB
kW
kWPower consumption
°CDBCertified operation range
Certified operation range
Motor output
CoolingNight quiet mode
Compressor
ModelName
Indoor unitOutdoor unit
Outdoor unit
Dimensions (HXWXD)
Colour
mmdB(A)
kWRefrigerant charge (R-410A) kg
dB(A)dB(A)
Sound level3
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Machine weight kg
Airflow rate (SH/H/L) m3/min
Outdoorunit
Colour
mm
Heat insulation
Max. interunit piping length mmMax. installation level difference
Power supply
Type
Sound level (H/M/L)3
Indoorunit
Both liquid and gas piping
Cooling capacity1,2
Rated (Min. - Max.)
cfm
140FHQ140CAVEBRZR140LVVM
46/42/38
Hermetically sealed scroll type
34/29/241,200/1,024/847
13.3 (6.2-15.4)
3.1
4544 46
Fresh white
4.68
21 to 46
14 to 25
125FHQ125CAVEBRZR125LVVM
44/41/37235X1,590X690
1,170X900X32097
38
50
31/27/231,094/953/812
12.5 (5.7-14.0)
2.43.15
(Charged for 30 m)
4.01
1 Phase, 220–230 V, 60 Hz
50 (Equivalent length 70)
71FHQ71CAVEBRZR71LVVM
1.76
2.373.30W/WCOP 2.843.123.00
7.1 (3.2-8.0)
Cooling
25 26
°CWB
Cooling capacity1,2
Rated (Min. - Max.) kWkW
W/WPower consumption
°CDBCertified Operation range
Certified Operation range
Sound level3
Motor outputCompressor
ModelName
Indoor unitOutdoor unitOutdoor unit
Dimensions (HXWXD)
Colour
mmdB(A)
kWRefrigerant charge (R-410A) kg
dB(A)dB(A)
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Machine weight kg
Airflow rate (H/M/L)
Outdoorunit
Colour
mm
Heat insulation
Max. interunit piping length mmMax. installation level difference
Power supply
Type
Cooling1
CoolingNight quiet mode
Sound level (H/M/L)3
Indoorunit
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).2Capacities are net, including a deduction for cooling for indoor fan motor heat.3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
WALL MOUNTED TYPE
m3/min
100FAQ100CVEARZR100LVVM
49/45/41
17340X1,200X240
o/ 9.5
49
Ivory white
30Both liquid and gas piping
Fresh white
o/ 15.9
Hermetically sealed swing type
o/ 26.0 (Hole)
1.6 (Charged for 30 m) 2.7 (Charged for 30 m)
10.0(5.0-11.2)
26/23/19
21 to 46
50 (Equivalent length 70m)
14 to 25
71FAQ71CVEARZR71LVVM
7.1(3.2-8.0)
45/42/40
484544
900X940X320595X845X3007843
2.031.76
290X1,050X23813
VP13 (O.Do/ 18 X I.Do/ 13)
18/16/14cfm 918/812/671635/565/494
2.19 3.37COP 3.24 2.97
1 Phase, 220–240 V, 50 Hz/220–230 V, 60 Hz
Power supply 1 Phase, 220 V, 60 Hz1 Phase, 220–230 V, 60 Hz
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
ModelName
Indoor unitOutdoor unitIndoor unitOutdoor unit
kW
°CDBCooling
°CWBCooling
Cooling
Cooling
Certified Operation range
Certified Operation range
Motor outputCompressor
Indoorunit
Dimensions (HXWXD)Air filter
Colour
mm
dB(A)
kWRefrigerant charge (R-410A)Sound level4
Cooling (H/L)Sound level4
dB(A)Cooling (H/L)Sound level4Air filter
dB(A)
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Machine weight kg
kg
Airflow rate(H/L)
Fan
CoolingAirflow rate(H/L)
Fan
Outdoorunit
Colour
Heat insulation
Max. interunit piping length mmMax. installation level difference
Type
----------
Both liquid and gas piping
mmOutdoor unit
Ivory white
kWCoolingPower consumption
Pa
cfm
Night quiet mode dB(A)
External static pressure(Middle-High)
Cooling capacity1,2
Rated (Min. - Max.)
30
21 to 46
14 to 25
m3/min
50FBQ50DAVETRZR50LVVM
5.0 (2.3-5.6)
50 (Equivalent length 70)
VP25 (I.Do/ 25XO.Do/ 32)
o/ 9.5o/ 15.9
o/ 26.0 (Hole)
1.12
1.39
60FBQ60DAVETRZR60LVVM
6.0(2.6-6.3)
300X1,000X700---------- 5
36
595X845X30043
Hermetically sealed swing type1.351.6
(Charged for 30 m)
635/53018/15
1.69
37/32
48
71FBQ71DAVETRZR71LVVM
7.1 (3.2-8.0)
1.76
2.22
2.9
140FBQ140DAVETRZR140LVVM
14.0(6.2-15.4)
4.71
45 4644
50-200 3
PaExternal static pressure(Middle-High) 50-200 3
100FBQ100DAVETRZR100LVVM
990X940X320
10.0 (5.0-11.2)
78
2.032.7
(Charged for 30 m)
1,130/81232/23
2.82
38/33
49
125FBQ125DAVETRZR125LVVM
12.5 (5.7-14.0)
300X1,400X70046
1,377/988
2.43.15
(Charged for 30 m)
39/28
3.73
40/36
1,170X900X32097
5045
125FBQ60DAVETx2RZR125LVVM
12.5 (5.7-14.0)
2.4
635/53018/15
3.73
37/32
300X1,000X70036
140FBQ71DAVETx2RZR140LVVM
14.0(6.2-15.4)
4.71W/WCOP 3.60 3.56 3.20 2.973.55 3.35 3.35 2.97
2.9
46
Hermetically sealed scroll type
3.16 3.153.19 3.16 3.153.193.96 4.223.13 3.96 4.163.13
Note : 1Rated cooling capacities are based on the following conditions: Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)2Capacities are net, including a deduction for cooling for indoor fan motor heat.3Initial setting is standard.4Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.5Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency(gravity method) 50% or more.
Cooling capacity1,2
Rated (Min. - Max.) kW
°CDBCoolingCertified Operation range
Sound level4
°CWBCoolingCertified Operation range
Motor outputCompressor
ModelName
Indoor unitOutdoor unit
Outdoor unit
Dimensions (HXWXD)
Colour
mm
kWRefrigerant charge (R-410A) kg
dB(A)dB(A)
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Machine weight kg
m3/mincfm
Outdoorunit
Colour
mm
Heat insulation
Max. interunit piping length mmMax. installation level difference
Power supply
Type
CoolingNight quiet mode
Indoorunit
140FBQ140DAVETRZQ140KCTLT
Hermetically sealed scroll type
13.3 (6.2–15.8)
100FBQ100DAVETRZQ100LUYLT
38 / 33
101
32 / 23
10.0 (5.0–11.4)
125FBQ125DAVETRZQ125LUYLT
40 /36
o/ 9.5o/ 15.9
50
----------
3 Phase, 220V, 60HzIndoor unit 1 Phase, 220V, 60Hz
3 Phase, 380V, 60Hz
30
Ivory white
Both liquid and gas piping
70 (Equivalent length 90 m)o/ 26.0 (Hole)
VP25 (I.Do/ 25XO.Do/ 32)
39 / 281,130 / 812 1,377 / 988
12.5 (6.0–14.3)
140FBQ140DAVETRZQ140LUYLT
-5 to 50
14 to 25
13.1 (6.2–15.8)
kWPower consumption Cooling
100FBQ100DAVETRZQ100KCTLT
10.0 (5.0–11.4)
125FBQ125DAVETRZQ125KCTLT
38 / 33---------- 5
40 /36
4945
1,170X900X32099
46300X1,400X700
3.7 (Charged for 30 m)
32 / 231,130 / 812
39 / 281,377 / 988
12.5 (6.0–14.3)
W/WCOP
2.41.9 2.9 2.41.8 2.9
Indoor unit
For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option (shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect.A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation.
Round flow type: List of optional parts required to achieve different flow patterns
1In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check whether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable.
2Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position.3It is not possible to use panel spacers in a 2-way flow installation. 4It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed.
Panel/grille relatedIndependently installable optional parts
Operation control relatedAuxillary function related
Filter related
Optional accessory parts
Independently installable optional partsOptional accessory parts
Independently installable optional partsOptional accessory parts
Panel spacer1
Panel spacer1 o o ox oWireless remote controller o o oo o
Fresh air intake kit (direct mount) o o oo ox o o
xx
High-efficiency filter2
Filter related Ultra-long-life filter2
o o ox
xUltra-long-life filter2 o o o xx
High-humidity operation kit
Panel/grille relatedOperation control relatedAuxillary function related
Panel spacer1
Wireless remote controller
Fresh air intake kit (direct mount)High-humidity operation kit
All round flow 4-way flow
o3 o3 xx o3
o3 o
x
xxo o
o3 o xx
o ox o o x
o3 o o xx
3-way flow 2-way flow
1-way branch / unit 3-way flowBranch duct1(Chamber type)(Round duct type)
o o o4 xx o2-way branch / unit 2-way flow1-way branch / unit 2-way flow
x o o4 xx ox o o4 xx o
Branch duct connection
Wireless remote controller
Fresh air intake kit (direct mount)
High-efficiency filter2
High-humidity operation kit
Ultra-long-life filter2
Panel spacer1 Wireless remote controller
Fresh air intake kit (direct mount)
High-efficiency filter2
High-humidity operation kit
Ultra-long-life filter2
Panel spacer1 Wireless remote controller
Fresh air intake kit (direct mount)
Fresh air intake kit (Chamber type)1,2 o o ox o
Fresh air intake kit (Chamber type)1,2 o3 o xx o
oo
xoo
o3
o
x
x
x
o
o o o
Fresh air intake kit (Chamber type)1,2
Fresh air intake kit (Chamber type)1,2
Fresh air intake kit (Chamber type)1,2
High-efficiency filter2
High-humidity operation kit
Ultra-long-life filter2
OPTIONS
Touch Controller4 DCS601C51
Note: 1Refer to page 8 for the details. 2Required for installing high-efficiency filter or ultra long-life filter. 3Wiring for wired remote controller to be procured locally.4The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 5Installation box for adaptor PCB (KRP1H98) is necessary.
Kit name
DCS302CA61BRC1E62
DCS301BA61DST301BA61
KRP1C63
KDDFP55B160
KDBH55K160FKDBP55H160FA
KKSJ55KA160
KDDP55B160KDDP55B160KKDDP55X160
KRP4AA53
KAFP551K160
KAFP556B80KAFP557B80KAFP552B80
KDTP55K80
KDJP55B160KDJP55B80BRC7F633FBRC1C61
KAFP553B80
KDTP55K160KAFP556B160KAFP557B160KAFP552B160KAFP553B160
BYCP125K-W1
KRP1H98
KAFP55B160KAFP55H160H
FCQ71KVEA FCQ100KVEA FCQ125KVEAFCQ50KVEA FCQ60KVEA FCQ140KVEA FCQ100KVLT FCQ125KAVLT FCQ140KAVLTName of option Remark
Chamber type
Decoration panel
Fresh air intake kit1
Central remote controller4
Unified ON/OFF controller4
Schedule timer4
Adaptor for wiring5
Without the T-joint pipe and fanWith the T-joint pipe, without fan
Direct installation type
Sealing material of air discharge outletPanel spacer
Chamber connection kit2Insulation kit for high humidity
Wiring adaptor for electrical appendices5
Installation box for adaptor PCB
High-efficiency filter(including chamber)
Filter chamber Replacement long-life filterUltra long-life filterReplacement ultra long-life filter
(Colorimetric method 65%)(Colorimetric method 90%)
Replacement high-efficiency filter
(Colorimetric method 65%)(Colorimetric method 90%)
Remote controller
Navigation Remote Controller
Wireless type Cooling only
Wired type3Wired type3
Branch duct chamber
Remote sensor (for indoor temperature) KRCS01-4B
CEILING MOUNTED CASSETTE TYPE
27 28
FLOOR STANDING TYPE
SPECIFICATIONS
Power supply 1 Phase, 220–240 V, 50 Hz/220–230 V, 60 Hz
Note : 1Rated cooling capacities are based on the following conditions: Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)2Capacities are net, including a deduction for cooling for indoor fan motor heat.3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
ModelName
Indoor unitOutdoor unitOutdoor unit
kW
°CDBCooling
°CWBCooling
Cooling
Cooling
Certified Operation range
Certified Operation range
Motor outputCompressor
Indoorunit
Dimensions (HXWXD)
Colour
mmdB(A)
kWRefrigerant charge (R-410A)Sound level3
Cooling (H/M/L)Sound level3
dB(A)
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Machine weight kg
kg
Airflow rate(H/M/L)
Fan
Outdoorunit
Colour
Heat insulation
Max. interunit piping length mmMax. installation level difference
Type
Fresh white
Both liquid and gas piping
mmOutdoor unit
Ivory white
kWCoolingPower consumption
cfm
Night quiet mode dB(A)
Cooling capacity1,2
Rated (Min. - Max.)
30
21 to 46
14 to 25
m3/min
50 (Equivalent length 70)
VP20 (I.Do/ 20XO.Do/ 26)
o/ 9.5o/ 15.9
o/ 26.0 (Hole)
1,850X600X27039
595X845X30043
Hermetically sealed swing type
1.6 (Charged for 30 m)
635/565/49418/16/14
43/41/38
48
71FVQ71CVEBRZR71LVVM
60FVQ60CVE
RZR60LVVM
50FVQ50CVE
RZR50LVVM
7.1 (3.2-8.0)
1.761.351.12
2.58
3.1
140FVQ140CVEBRZR140LVVM
13.5(6.2-15.4)
5.40
45 4644
100FVQ100CVEBRZR100LVVM
990X940X320
10.0 (5.0-11.2)
78
2.032.7
(Charged for 30 m)
988/883/77728/25/22
988/918/84728/26/24
1,059/988/91830/28/26
3.28
50/47/44
49
125FVQ125CVEBRZR125LVVM
12.5 (5.7-14.0)
1,850X600X35047
2.43.15
(Charged for 30 m)
4.39
53/51/4851/48/46
1,170X900X32097
50
635/565/49418/16/14
45
125FVQ60CVEx2RZR125LVVM
12.5 (5.7-14.0)
97
2.4
4.39
43/41/381,850X600X270
39
140FVQ71CVEBx2RZR140LVVM
13.5(6.2-15.4)
5.40W/WCOP 2.75
6.0 (2.6-6.3)
1.843.26
5.0 (2.3-5,6)
1.273.94 2.503.05 2.85 2.85 2.50
3.1
46
Hermetically sealed scroll type
Indoor unitCEILING SUSPENDED TYPE
Kit nameName of option Remark
L-type piping kit (for upward direction)Drain pump kitFresh air intake kit
Remote controller Wireless type
Central remote controller2
Unified ON/OFF controller2
Schedule timer2
Adaptor for wiringWiring adaptor for electrical appendices3
Installation box for adaptor PCB
Note: 1Wiring for wired remote controller to be procured locally.2The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.3Installation box for adaptor PCB is necessary.
FHQ71CAVEB FHQ100CAVEB FHQ125CAVEB FHQ140CAVEB
Remote sensor (for indoor temperature)Electrical box with earth terminal (3 blocks)Electrical box with earth terminal (2 blocks)
Wired type1 BRC1C61
KRP1BA54
DCS302CA61DCS301BA61DST301BA61
KRP4AA52
KDU50P140VEKDDQ50A140
Long-life filter KAFP501A160KAFP501A80
BRC7GA56
KRP1D93A
KHFP5N160
KRCS01-4BKJB311AAKJB212AA
Cooling only
Touch Controller2
Note: 1Wiring for wired remote controller to be procured locally.2The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.3Installation box for adaptor PCB (KRP4AA93) is necessary.
WALL MOUNTED TYPEName of option Remark
Central remote controller2
Remote controller
Unified ON/OFF controller2
Schedule timer2
Wiring adaptor for electrical appendices3
Electrical box with earth terminal (3 blocks)Electrical box with earth terminal (2 blocks)
Kit nameFAQ100CVEA
DCS302CA61DCS301BA61DST301BA61DCS601C51
DCS601C51
KRP4AA51
KJB311AAKJB212AA
Drain-up kit
Installation box for adaptor PCB
Noise filter ( For electromagnetic interface use only)
Remote sensor (for Indoor temperature) KRCS01-4B
FAQ71CVEAK-KDU572EVE
KRP4AA93
KEK26-1A
BRC7EB519BRC1C61
Wireless typeWired type1
BRC1E62Navigation Remote Controller Wired type1
BRC1E62Navigation Remote Controller Wired type1
Cooling only
Touch Controller2
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
OPTIONS
Outdoor unitKit name
RZR71LVVM RZR100LVVMRZR50LVVM RZR60LVVM RZR125LVVM RZR140LVVMCentral drain plug
Central drain plugFixture for preventing overturning Base stationary type
Wire typeDemand adaptor
Wire fixture for preventing overturning
Name of option
Kit nameRZQ140KCTLT RZQ100LUYLTRZQ100KCTLT RZQ125KCTLT RZQ125LUYLT RZQ140LUYLTName of option
Fixture for preventing overturningDemand adaptorRefrigerant branch piping kit For twin multi
KKPJ5F180K-KYZP15C
KHRP58P216T
KPT-60B160
KKPJ5G280----------
KKTP5B112
KKPJ5F180KPT-60B160K-KYZP15CKRP58M51
KKP014A4------------------------------
----------KRP58M51
KDAJ25K71A
FBQ71DAVETFBQ60DAVETFBQ50DAVET FBQ100DAVET FBQ125DAVET FBQ140DAVET
Service panel
Air discharge adaptor
Adaptor for wiring (interlock for fresh air intake fan)
Remote controller Wireless type Cooling only
Name of option Remark
Filter chamberReplacement long life filterReplacement long life filter chamber kit
High-efficiency filter1 65%90%
BRC4C64
KTB25KA80WKTBJ25K80FKTBJ25K80T
KTB25KA160WKTBJ25K160FKTBJ25K160T
KAF372AA80KAF373AA80
KAF372AA160KAF373AA160
KDDF37AA80 KDDF37AA160KAF371AA80 KAF371AA160KAF375AA80 KAF375AA160
KDAJ25K140A
KRP1C64BRC1E62Navigation Remote Controller Wired type2BRC1C61Wired type2
Central remote controller3
Unified ON/OFF controller3
Schedule timer3
Wiring adaptor for electrical appendicesRemote sensorMounting plate for adaptor PCB.4
DCS301BA61DCS302CA61
DST301BA61
KRCS01-4BKRP4A96 5,6
KRP4AA51
Note: 1If installing a high efficiency filter on the unit, an assembly chamber for either bottom or rear suction is required. 2Wiring for wired remote controller to be procured locally. 3The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 4Mounting plate for adaptor PCB is necessary for each adaptor marked . 5Up to 2 adaptors can be fixed for each mounting plate.6Only one mounting plate can be installed for each indoor unit.
DCS601C51Touch Controller3
Kit name
29 30
Indoor unit
FLOOR STANDING TYPEKit nameName of option FVQ71CVEB FVQ100CVEBFVQ50CVE FVQ60CVE
DCS302CA61DCS301BA61DST301BA61
KAFJ95L160Remark
Touch Controller2
Replacement long-life filter
Navigation Remote ControllerCentral remote controller2
Unified ON/OFF controller2
Schedule timer2
Adaptor for wiring3
Wiring adaptor for electrical appendicesInstallation box for adaptor PCB
Note: 1Wiring for wired remote controller to be procured locally. 2The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.3Installation box for adaptor PCB (KRP4AA95) is necessary.
FVQ125CVEB FVQ140CVEB
KRP1BA57DCS601C51
KRP4AA52KRP4AA95
BRC1E62Wired type1Remote controller BRC1C61Wired type1
DIMENSIONS (Unit: mm)
CEILING MOUNTED CASSETTE TYPE
Notes:1Sticking location for manufacture's label manufacture's label for indoor unit: Suction grille inner side's electric components box's lid surface manufacture's label for decoration panel : Decoration panel's corner decoration cover inner surface2In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail.
3When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required.
4Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less between the indoor unit and the ceiling opening so that
the panel overlap allowance can be ensured.5Please do not place the thing been damp and troubled under an indoor unit. When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
950
8Piping ConnectionSide
6
A arrow view
Drain ConnectionSide
Note 2
7
9509
860~91
0(Ceilin
g open
ing sp
ace) (N
ote 4)
420
C
710(Hanging bolt pitch)420
B
300or less
780(
Hang
ing b
olt p
itch)
860~910(Ceiling opening space) (Note 4)
157
93
2x100=200 85
67
Connection positionof branch duct
C/L(round shape type)160
Connection positionof branch duct
16-M4 Hole
167
(square-shaped type)B arrow view
160
95
81
350
29213
29
350
80
160
ø100
Connection positionof fresh air intake kit
C/L 157
90
(direct installation type)
67
(knock hole)
Connection positionof branch duct
C arrow view
Connection positionof branch duct
2x100=
200
(round shape type)
(square-shaped type)
196
93
90
8025
95
160
20-M4Prepared hole
167
280
5028
8
80
167
95
157
340840
16510
4Hanging bolt 1
175
55
4-M8~M10Connection positionof branch duct(round shape type)
Connection positionof branch duct
2
40
80
160
2x100=200
125
(square-shaped type)
C/L
298
20
350
850
Adjust
able(0
~675) 55
29
330
160
16-M4 Prepared hole
160
1500 o
r more
81
93
157
130
Connection positionof branch duct
160
2x100=200
A
55
(square-shaped type)
From the
floor side
2500 or
more
(Note 4)
67
105
For he
ight in
stallat
ion
85
150
(require
d spac
e)
350
42
29
64
(round shape type)
27-M4 Prepared hole
60
35 or less (Note 4) 35 or less
3
Connection positionof branch duct
256
160 5
95
50
84055
167
The necessary space is 500mm or more when the air-outlet is blocked with the accessory.Moreover when the corner areas are blocked (both right and left of the blocked air outlet), the necessary space is 200mm or more.
1500mm or more200mm or more
1500mm or more
1500mm or more1500mm or more200mmor more
Required space
95
330
165
Connection positionof branch duct
160
20
16-M4 Prepared hole
50
350
12480
175
125
2
(square-shaped type)
4 1157
246
55
4-M8~M10
2x100=200 80
124
10
Hanging bolt
Connection positionof branch duct
C/L
110
(round shape type)
84055
280
256
40
Adjust
able(0
~675)
340
850
Connection positionof branch duct
1500 o
r more
Connection positionof branch duct
27-M4 Prepared hole
60
From the
floor side
2500 or
more
130
124
2x100=200
35 or less (Note 4)
55
A
150
84055
160
157256
105
(square-shaped type)
For he
ight in
stallat
ion
42
(require
d spac
e)
(Note 4)
95
3 85124
35 or less
5
(round shape type)
64
350
81
11050
124
81 2x100=200
350
Connection positionof branch duct
160
16-M4 Hole
B arrow view
(round shape type)
110
C/L124
85
157
(square-shaped type)
95
Connection positionof branch duct
80
157
213
95
160
Connection positionof fresh air intake kit
(square-shaped type)
C arrow view
(knock hole)90(round shape type)
124
183
109
25
C/L
124
802x1
00=200
(direct installation type)
ø100
20-M4Prepared hole
Connection positionof branch duct
Connection positionof branch duct
90
350
[FCQ50-140] [FCQ50-140] [FCQ100-140]
[FCQ50-71] [FCQ50-71]
[FCQ100-140] [FCQ100-140]
[FCQ50-71]
[FCQ50-71] [FCQ100-140]
Liquid piping connectionGas piping connectionDrain piping connectionTransmission wiring connectionRemote controller wiring connectionAir-outletSuction grilleCorner decoration coverDrain hose (accessory)
12345
6789
131102
10260 116
20
210
19587
18 17
1230
100
5716
30
210
189
163
35
105
8
156
(Han
ging
bolt p
itch)
(Hanging bolt pitch)
1270
1
235
Hanging bolt4 M8~M10
(Service space)30 or more 30 or more
(Service space)
519
7
13
690
57
ObstacleFloor side
300 o
r more
(Requir
ed spa
ce)
(Req
uired
spac
e)
For h
eight
instal
lation
From t
he floo
r side 2
500 or
more
221
83 4
268
268
5156
214
6
10576 23 7
The Front
Drain piping connection VP20(For left piping)
(Note.2)Brand name plate
4
57
131
19791
11
6 14
5
o/ 45
90
63
175
90
12
120
59
115
157
63
5140
13460
9
92
Connection position of fresh air intake kitφ100(Knock out hole)
Position slit hole for taking out in piping back(View from the front)
175
5
10319 15220
(Req
uired
spac
e)
Position : Hole of wall for taking out in piping back(View from the front)
235
Hanging bolt1
30 or more1590(Service space)
4 M8~M10
(Service space)30 or more
11
131
197
6 57o/ 45
91
4 5
14
83
156
6
268
42
221
Drain piping connection VP20(For left piping)
76 3 5
(Note.2)Brand name plate
7
The Front
214268
105
195
156
189100
8
210
1550
260
57
210
163
2018
116
(Han
ging
bolt p
itch)
(Hanging bolt pitch)
17
30
10516
87
131 35
102
10
13
300 o
r more
197
690
57
ObstacleFloor side
(Req
uired
spac
e)
(Requir
ed spa
ce)
5Fo
r heig
ht ins
tallat
ionFro
m the
floor sid
e 2500
or mo
re
19 103
(Req
uired
spac
e)5
22015
175
Position : Hole of wall for taking out in piping back(View from the front)
40
59
115
63
Connection position of fresh air intake kit12090
51
90
φ100(Knock out hole) 9
1579217
5
1341263
60Position slit hole for taking out in piping back
(View from the front)
DIMENSIONS (Unit: mm)
31 32
CEILING SUSPENDED TYPE
Notes:12
3
Location of unit's Name Plate: Bottom of fan housing inside the suction grille.In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail.Please do not place the thing been damp and troubled under an indoor unit.When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
CEILING SUSPENDED TYPE
[FHQ100-140CAVEB]
[FHQ71CAVEB]
Notes:12
3
Location of unit's Name Plate: Bottom of fan housing inside the suction grille.In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail.Please do not place the thing been damp and troubled under an indoor unit.When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
1234567891011121314151617181920
Air discharge grilleAir suction grilleAir filterGas piping connectionLiquid piping connection Drain piping connectionEarth terminal (inside the control box) (M4)HangerRear piping penetration coverTop panel penetration coverRight side piping connection Left back drain piping connection Left side drain piping connection Right side drain piping connection Hole of wall for taking out in piping back Upward drain piping connection Upward gas piping connection Upward liquid piping connectionPower supply wiring and a unit wiring back connectionPower supply wiring and a unit wiring upper connection
1234567891011121314151617181920
Air discharge grilleAir suction grilleAir filterGas piping connectionLiquid piping connection Drain piping connectionEarth terminal (inside the control box) (M4)HangerRear piping penetration coverTop panel penetration coverRight side piping connection Left back drain piping connection Left side drain piping connection Right side drain piping connection Hole of wall for taking out in piping back Upward drain piping connection Upward gas piping connection Upward liquid piping connectionPower supply wiring and a unit wiring back connectionPower supply wiring and a unit wiring upper connection
6
φ80 hole
5
φ80 hole894
Approx.475
52
105
104
98
Piping and Wiring intakeOutside line
14.5
44
Mounting location 460
44
Approx.390Approx.345
8
120 or lessFor installation in high spaces
50 o
r mor
e
2500 or more
30 o
r mor
e(R
equir
ed sp
ace)
(Req
uired
spac
e)
Piping direction
2 19
238
Approx.400
290
240
Dimensions for full open front panel
3
50 or moreName plate Note)2
50 or morePiping directionPiping direction
1050
7
(Requred space) (Requred space)
WALL MOUNTED TYPE
[FAQ71CVEA]
Front panelFront grillAir outletGas pipingLiquid pipingDrain hoseEarth terminalRight side piping connection holeLeft side piping connection hole
123456789
Notes:123
Location of unit's of Name Plate:Right side surface of casingIn case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote contorller in detail.Please do not place the thing been damp and troubled under an indoor unit. when the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
Approx.4005
65
45
445
Piping and Wiring intake
79.5
Approx.465
6
Mounting location
φ80 hole
114
1085
14.5
φ80 hole
Outside line
Approx.46089
35.5
Piping direction
(Req
uired
spac
e)(R
equir
ed sp
ace)
120 or less
8
2500 or moreFor installation in high spaces
50 o
r mor
e30
or m
ore
(Requred space) (Requred space)1200
7
50 or more 50 or morePiping directionName plate Note)2Piping direction3
9
Approx.440
Dimensions for full open front panel
242
340
2 1
240
WALL MOUNTED TYPE
[FAQ100CVEA]
Front panelFront grillAir outletGas pipingLiquid pipingDrain hoseEarth terminalRight side piping connection holeLeft side piping connection hole
123456789
Notes:123
Location of unit's of Name Plate:Right side surface of casingIn case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote contorller in detail.Please do not place the thing been damp and troubled under an indoor unit. when the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
This model to be fixed with fixture as shown below.
In case of fixing it at the bottomIn case vibration resistance is required, fix it at both the bottom and the rear.
50 or more
1500 or more
50 or more
Required space
AB
100
C
50
Detail
0.7
Suction grille stopper
(Two both sides)
18
2-7X15 oblong hole
184 184
(For wood screw)(Accessory)
330 30
Fixture
95
666
E G
68
Full open position of suction grille
H
Pull out direction of air-filter
F
D
75
KJ
L
740
or m
ore
(Pull o
ut dim
ensio
n of a
ir-filte
r)
5010
0
Approx.46
2
1
3
5
4
200
34 223
825
600
1850
314
253
95
598
677
616
541
8
9
10
130 215 126
PN
260
M
130
View
7
4- 14 Hole(For bolt)
(From the Air outlet)
View
150
760
150
785
245
215
5X150=750 43
435 16-8X12 oblong hole(All around)
3
3X65
=195
300
5
169
2X65
=130
290
26
300
or m
ore
(A c
ase
with
out
the
ceili
ng)
(Not
e.4)7
144
2500
or
mor
e
28
6
4
700
1 2
212
Air outlet
Ceilling
Air inlet(Note.2)
Floor surface
950
513
150 15
0(All around)
18-8X12 oblong hole
6X150=900
925
80
277
247
(From the Air inlet)
(All around)
1038
(S
uspe
ntio
n bo
lt po
sitio
n)
(Ser
vice
spa
ce)
11X6
5=71
5
9
450
or m
ore 65
13X6
5=84
5
1000
631
805
10
200
8
or le
ss
(All around)
700 or more(Service space)
(Suspention bolt position)
Inspection hatch 450 or more
Air inletAir outlet
30-φ4.7 hole 36-φ4.7 hole
B
Control box(450mmX450mm)Inspection hatch 1
View B-1
CASE 1)
Control box
or le
ss
Inspection hatch 1(450mmX450mm)
200
Ceiling
Control box
Inspection hatch
Fig.A
CASE2), 3)
or m
ore
or le
ss
or m
ore
200
1000
or more700
Inspection hatch 2
(same as the indoorunit size or more)
View B-2
Control box
Inspection hatch 3(Same as the indoorunit size + 300 or more)
or more700
1300
20
Inspection hatch
Control box
or m
ore
Ceiling
Airoutlet
Unit baseAir inlet
300
or m
ore
DIMENSIONS (Unit: mm)
33 34
[FBQ50/60/71DAVET]
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
According to any one of below 1) ~3), secure a space for service works, such as, checking and maintenance of control box, etc.
Notes)1 Location of MANUFACTURE'S LABEL: Control box surface2 Mount the air filter at the suction side. (Select its colorimethod (gravity method) 50% or more.)3 Do not locate things should not be wet under the indoor unit. Dews may drop when humidity reaches over 80%, or a drain gets stuck, or air filters are not clean.4 Space for Service Works
1) One inspection hatch (450X450) on the control box side and a space of 300mm or more under the unit. (Fig.A)2) One inspection hatch (450X450) on the control box side and 2 (two) inspection hatches under the unit. (Arrow View B-1)3) 3 (three) inspection hatches under the unit and the control box. (Arrow View B-2)
Liquid pipe connection Gas pipe connectionDrain pipe connectionGround terminal (Terminal in Control box)Control box (Inside)Remote control wiring connectionPower-source wiring and a unit wiring connectionAir discharge flangeAir suction flangeHook
1234567
8910
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
(SAME AS THE INDOOR UNIT SIZE OR MORE)
Fig.AAir outlet
Inspection hatch 1(450mmX450mm)
Air inletUnit base
Control box
200
or le
ssCASE 1)
300
or m
ore
Inspection hatch
Control box
Ceiling
150
215
View
165 49
1160
245
(From the Air outlet)
7X150=1050
(All around)20-8X12 oblong hole635
1185
40
232
212
167
(467 or l
ess) 3
300
7169
1
(A ca
se wi
thout
the ce
iling)
6
2X65
=130
290
(Not
e.4)
300 o
r more4
2
28
144
70011
700
or le
ss 5
3X65
=195
2500
or m
ore
Air outlet
Floor surface
Air inlet (Note.2)
Ceiling
Adjus
table
80
20-8X12 oblong hole
8X150=1200
1350
150
713300 or less
150 27
7
1325
12(All around)
247
(From the Air inlet)
(Serv
ice sp
ace)
27 63140- 4.7 Hole(All around) 48- 4.7 Hole
1438
(Han
ging
bolt p
itch)
700 or more
(Hanging bolt pitch)
9
16X6
5=10
40
(All around)8
10
19X6
5=12
35
450
or m
ore
200
or le
ss14
00
(Service space)
1205
65
Air inlet
Inspection hatch 450 or more
Air outlet
200
or less
Control box
Inspection hatch 1(450mmX450mm)
700 or more
(SAME AS THE INDOOR UNIT SIZE OR MORE)
Inspection hatch 2
1400
or more 170
0 or m
ore
Control box
(SAME AS THE INDOOR UNIT SIZE +300 OR MORE)
Inspection hatch 3
700 or more
View B-2
CASE 2),3)
CeilingInspection hatch
B
20
or m
ore
Control box
View B-1
According to any one of below 1)~3),secure a space for service works,such as,checking and maintenance of control box,etc.
1)One inspection hatch (450X450) on the control box side and a space of 300mm or more under the unit.(Fig.A)2)One inspection hatch (450X450) on the control box side and 2 (two) inspection hatches under the unit.(Arrow View B-1)3)3 (three) inspection hatches under the unit and the control box.(Arrow View B-2)
Notes: 1Location of MANUFACTURE'S LABEL: Control box surface2Mount the air filter at the suction side.(Select its colorimethod (gravity method) 50% or more.3Do not locate things should not be wet under the indoor unit.Dews may drop when humidity reaches over 80%,or a drain gets stuck,or air filters are not clean.4Space for Service Works
[FBQ100/125/140DAVET]
Liquid piping connectionGas piping connectionDrain piping connectionEarth terminal(Terminal in Control box)Control box(Inside)Remote control wiring connectionPower supply wiring and a transmission wiringAir discharge flangeAir suction flangeHangerSocket (for maintenance)Drain hose(Accessory)
1234
56
7
89101112
FLOOR STANDING TYPE
Notes: 1Sticking location for manufacturer’s label: on the surface of cover of switch box inside the suction grille. 130
A
FVQ100/125/140CVEB50
190
B110
266
C186
350
D270
44
E45
49
F50
130
G50
190
H110
260
J180
266
K186
322
L242
79
M57
202
N144
229
P149FVQ50/60CVE, 71CVEB
Suction grilleAir filterThrough hole for side piping(70x90 oblong slit hole)Through hole for side piping( 80 slit hole)Through hole for side piping( 27 slit hole)Through hole for rear piping/wiring(80x130 oblong slit hole)Through hole for bottom piping/wiring(126x130 square hole)Liquid pipe connectionGas pipe connectionDrain pipe connection
123
4
5
6
7
8910
595
559
20094
449
509
419299
21Drain outlet
Drain outlet
163 112
272
479
269
Wiring inletName plate
20
573.5
845
342
7
78
2030
0
300131
326
Drain outletI.D. 18 hose for connection
Hole for anchor bolts (M8 or M10)
Liquid stop valve( 9.5CuT)
Earth terminal in switch box
Service port
Gas stop valve( 15.9CuT)
6010
5
Service port 144
OUTDOOR UNIT // RZR50/60/71LVVM
OUTDOOR UNIT // RZR125/140LVVM, RZQ100/125/140KCTLT, RZQ100/125/140LUYLT
6
5
13
52
7
5553
95
67
223
30
53
567
95
80
145
19
5584
3038
350
(345
~355
)
320
91
37
620160
30
Hole for anchor bolt 4-M12
160
55
279
90
16
285
36
416
260
262
595
68
8 16
161
561
340
940
95
60
5
3
990
89
7 6 89 53
21
142
4
19
339
DIMENSIONS (Unit: mm)
30
223
5
52
13
76
67
5595
53
19137645
102
117
70
16
71 16
58
5
8
5
7
95
19
84
8054
145
55
6
142
2
3
6
89
7
19
5
423
1170
4
422
9554
900
1
60 89
94
6130
350
(345
~355
)
43
620
320
41
140
30
140
Hole for anchorbolt 4-M12
Gas piping connectionLiquid piping connectionService portEarth terminalRefrigerant piping intakePower supply wiring intakeTransmission wiring intakeDrain outlet
12345678
OUTDOOR UNIT // RZR100LVVM
Gas piping connectionLiquid piping connectionService portEarth terminalRefrigerant piping intakePower supply wiring intakeTransmission wiring intakeDrain piping connection
12345678
35 36
REMOTE CONTROLLER
Wired type
Staple
Remote controller
17
17
0~5
117
Remote controller
Remote controller
(Between remote controller and control box)
17
• Installation methodA Exposed body, exposed cord C Exposed body, embedded codeB Exposed body, embedded cord
Conduit
Control box
Through hole
Size
Specifications of cord
0.75~1.25 mm2
Total length 500 m
Type Shield wire (insulated thickness: 1 mm or more) Note) 1. Remote controller cord and staple are not
attached. They are field supplied parts.
120
120
17 18
42
84
38
Cord outlet hole2823
46
• Remote controller dimensions
Wireless typeCEILING MOUNTED CASSETTE TYPE <Round Flow>• Remote controller dimensions
• Remote controller holderinstallation procedure<installation to wall surface>
• Receiver installation procedure
• Receiver detail
Transmitting part
157
62 17.5
Liquid crystalremote controller(wireless)
Remote controllerholder
CEILING SUSPENDED TYPE
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
• Receiver installation procedure
120
72 83.5
106
(Ceil
ing op
ening
)
70 180.5
35 49
Service space for ceiling installation
• Receiver detail
Note :
Mor
e th
an 9
0(S
revic
e sp
ace)
(Ceiling opening)
2-5x9 Slot
Switch box(field Supplied parts)
Do not install more than 3 receivers in the vicinity of one another.With 4 or more units, there is always the possibility of malfunction
( 12- 16)
Receiver
Drain pipingside
Refrigerantpiping side
Decoration panel
WALL MOUNTED TYPE• Receiver installation procedure
BRC1C61
19
Upper case Lower case
40
2346
2848.5
4284
5X7 oblong hole
Code outlet hole5X15 oblong hole
Lower case portion
Lower case portion
Staple
19
A Exposed cord C Embedded cord(use switch box)
B Embedded cord
84
46Switch box for two switchex.) KJB211A(optional accessory)
Condit19
0~5
Switch box [field supplied part]
(Between remotecontroller and control box)
48.5
19
Note)2Through hole
40
( 8- 10)
84
28Switch box for one switchex.) KJB111A(optional accessory)
• Installation method
2.If the hole size is too large or the location is not proper, the hole may come out from the remote controller.
Note) 1. Remote controller cord and staple are not attached. They are field
supplied parts.
Size
Specifications of cord
0.75~1.25 mm2
Total length 500 m
Type Vinyl cord with sheath or cable (insulated thickness: 1mm or more)
BRC1E62
(Green)120
120
Operationlamp
Top left outlet
Left outlet
Top centeroutlet
• Receiver detail
The Front
• Receiver detail
Receiver
Receiver
Installation service space for outdoor unit
1000
or more
300 or more
L H
L H
H
L
500
or more100
or more
L H
For RZR50-140LVVM For RZQ100-140KCTLT, 100-140LUYLT
300
or more
1000 or more
200 or more
100
or more
100 or more 100 or more
100
or more
500 or more
When there are obstructions on the inlet side and both lateral sides
2. For series installation (more than two units)When there are obstructions on both sides
1. For single unit installation When there is an obstruction only on the inlet side
1. For single unit installation When there is an obstruction on the inlet side
2) When there is an obstruction in the overhead space
When there are obstructions on both sides
When there are obstructions on the inlet side and both lateral sides
2. For series installation (more than two units)
1. For single unit installation
2. For series installation (more than two units)
1. For single unit installation
2. For series installation (more than two units)
1. For single unit installation
2. For series installation (more than two units)
100
or more
500 or less
1000
or m
ore
An obstruction in the overhead space
500 or less
500 or more
1000
or m
ore
An obstruction in the overhead space
500 or less
1000 or more
1000
or m
ore
An obstruction in the overhead space
150
or more
150 or more 150 or more
500 or less
1000
or m
oreAn obstruction
in the overhead space
300
or more
1000 or more
200 or more
500 or less
1000
or m
ore
An obstruction in the overhead space
1.RZR50/60/71LVVM 2.RZR100-140LVVM
21
21
21
21
21
21
21
21
21
21
21
21
1000 or more
1) When the overhead space is open
2) When there is an obstruction in the overhead space
1) When the overhead space is openWhen there is an obstruction on the inlet side1 When there is an obstruction on the outlet side2
1000
or m
ore
500 or less
250 or more 150 or more150 or more
500 or less
200 or more
1000 or more 250 or more 250 or more
1000
or m
ore
250 or more200 or more250 or more
1000 or more
1000
or
mor
e
100 or more
500 or less
500 or more
50 or more
500 or more
50 or more
250 or more
1000
or m
ore
500 or less
1000 or more
1000 or more
250 or more
250 or more
1000
or more
200 or more
500 or more
500 or less
1000
or m
ore
100 or more
100 or more 250 or more
1) When the overhead space is open (There is no limit to the height of the obstruction on the outlet side.)
When there are obstructions on both the inlet and outlet sides(When the obstruction on the outlet side is higher than the unit itself)
3
Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book.37 38
1000 or more
100 or more 100 or more
1000
or more
300
or more
L H
L H
100 or more 100 or more
300 or more
1000 or more
200 or more
100 or more 100 or more
500 or less
1000 or more
1000
or
mor
e
An obstruction in the overhead space
100 or more
100 or more
300
or more
1000 or more
200 or more
500 or less
1000
or
mor
e
An obstruction in the overhead space
100 or more
100 or more
When there is an obstruction on the inlet side
When there are obstructions on the inlet side and both sides
2. For multiple units installation (more than two units)
When there are obstructions on both sides
1) When the overhead space is open
1. For single unit installation
When there is an obstruction only on the inlet side
2) When there is an obstruction in the overhead space
1) When the overhead space is open
When there are obstructions on both sides
2) When there is an obstruction in the overhead space
When there is an obstruction on the inlet side
When there are obstructions on the inlet side and both sides
2. For multiple units installation (more than two units)
1. For single unit installation
1. For single unit installation
2. For multiple units installation (more than two units)
1. For single unit installation
2. For multiple units installation (more than two units)
1. For single unit installation
2. For multiple units installation (more than two units)
Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book.
1 When there is an obstruction on the outlet side2
1) When the overhead space is open (There is no limit to the height of the obstruction on the outlet side.)
When there are obstructions on both the inlet and outlet sides(When the obstruction on the outlet side is higher than the unit itself)
3
H
L
500
or more
100
or more
L H
100 or more
100 or more100 or more
100 or more
500 or more
100 or more
500 or less
1000
or
mor
e
An obstruction in the overhead space
500 or less
500 or more
1000
or
mor
e
An obstruction in the overhead space
150 or more
150 or more150 or more
500 or less
1000
or
mor
e
An obstruction in the overhead space