florida meter approved meter equipment group enclosure list€¦ · served by the utilities of the...

14
The attached list of self-contained meter sockets and enclosures has been approved for use in the service areas served by the utilities of the Florida Meter Group. Approval is based on the unit's compliance with the FMG specifications, particularly U.L. listing, sealing requirements, bypass characteristics, and certain operational concerns. T FMG makes no claims regarding nameplate ratings or load side attachments beyond the sealed portion of the meter socket. We recommend that all units be used as intended by the manufacturer. All additional data is supplied for informational purposes only. NOTES: A. All commercial or three phase applications require a unit with an approved bypass device. (Configuration 3, 4 or 5) B. All sockets are listed as their maximum socket amperage. 320/400 Amp enclosures are listed as 400 Amp maximum and 480/600 Amp enclosures are listed as 600 Amp maximum. C. Aluminum enclosures are recommended in salt spray areas. D. Sealing rings (ring-type sockets) along with all lugs/connectors (line and load side) are considered to be part of the meter enclosure. The customer/contractor is thereby responsible for furnishing these items. Please contact your utility representative to determine the proper size lugs/connectors. The sealing ring must be a captive-screw type equivalent to ABB #01L0028G02, Milbank MR-4/A3068, Landis & Gyr #9738-8002, or Ekstrom 10-9090. E. The "configuration" refers to the various meter connecting arrangements used to accommodate the utility meter. These configurations are described below: SELF CONTAINED CONFIGURATIONS DESCRIPTION & TYPICAL APPLICATION 1 Residential - 4 Terminal Socket, Single Phase, 3 Wire 2 Residential - 5 Terminal Socket, Network, 3 Wire 3 Residential/Commercial - 4 Terminal Socket (w/Bypass), Single Phase, 3 Wire 3a Residential/Commercial - 5 Terminal Socket (w/Bypass), Network, 3 Wire 4 Commercial - 7 Terminal Socket (w/Bypass), Three Phase, 4 Wire *5 Residential/Commercial K7 Base (w/Bypass), Single Phase (FPL Only), Three Phase or Network, 3 or 4 Wire *K7 Three Phase K-Base applications are ONLY allowed at FPL (GULF, PEF, and TECO do not allow any K-base installations) Enclosure List: Revised 4/6/2012 Florida Meter Group Approved Meter Equipment Participants: Participants: FPL, GULF, PEF, TECO Page 1 of 14 FPL - Florida Power Light PEF - Progress Energy-Florida TECO - Tampa Electric GULF - Gulf Power © 2005, Florida Meter Group

Upload: others

Post on 15-May-2020

28 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Florida Meter Approved Meter Equipment Group Enclosure List€¦ · served by the utilities of the Florida Meter Group. Approval is based on the unit's compliance with the FMG specifications,

The attached list of self-contained meter sockets and enclosures has been approved for use in the service areas served by the utilities of the Florida Meter Group. Approval is based on the unit's compliance with the FMG specifications, particularly U.L. listing, sealing requirements, bypass characteristics, and certain operational concerns. The FMG makes no claims regarding nameplate ratings or load side attachments beyond the sealed portion of the

meter socket. We recommend that all units be used as intended by the manufacturer. All additional data is supplied for informational purposes only.

NOTES: A. All commercial or three phase applications require a unit with an approved bypass device.

(Configuration 3, 4 or 5)

B. All sockets are listed as their maximum socket amperage. 320/400 Amp enclosures are listed as 400 Amp

maximum and 480/600 Amp enclosures are listed as 600 Amp maximum. C. Aluminum enclosures are recommended in salt spray areas.

D. Sealing rings (ring-type sockets) along with all lugs/connectors (line and load side) are considered to be part of the meter enclosure. The customer/contractor is thereby responsible for furnishing these

items. Please contact your utility representative to determine the proper size lugs/connectors. The sealing ring must be a captive-screw type equivalent to ABB #01L0028G02, Milbank MR-4/A3068,

Landis & Gyr #9738-8002, or Ekstrom 10-9090.

E. The "configuration" refers to the various meter connecting arrangements used to accommodate the utility meter. These configurations are described below:

SELF CONTAINED

CONFIGURATIONS DESCRIPTION & TYPICAL APPLICATION

1 Residential - 4 Terminal Socket, Single Phase, 3 Wire 2 Residential - 5 Terminal Socket, Network, 3 Wire

3 Residential/Commercial - 4 Terminal Socket (w/Bypass), Single Phase, 3 Wire 3a Residential/Commercial - 5 Terminal Socket (w/Bypass), Network, 3 Wire 4 Commercial - 7 Terminal Socket (w/Bypass), Three Phase, 4 Wire *5 Residential/Commercial – K7 Base (w/Bypass), Single Phase (FPL Only),

Three Phase or Network, 3 or 4 Wire

*K7 Three Phase K-Base applications are ONLY allowed at FPL

(GULF, PEF, and TECO do not allow any K-base installations)

Enclosure List:Revised

4/6/2012

FloridaMeterGroup

Approved Meter Equipment

Participants:

Participants: FPL, GULF, PEF, TECO

Page 1 of 14

FPL - Florida Power Light PEF - Progress Energy-Florida TECO - Tampa Electric GULF - Gulf Power

© 2005, Florida Meter Group

Page 2: Florida Meter Approved Meter Equipment Group Enclosure List€¦ · served by the utilities of the Florida Meter Group. Approval is based on the unit's compliance with the FMG specifications,

Manufacturer Catalog NumberAmps Phase Service Pos Term Bypass Config

Approved Metering Equipment Enclosure List

Participants: FPL, GULF, PEF, TECO

Revised

4/6/2012

Durham UTZ-6R1131C-FL100 1 Ov/Un 6 5 N 1,2

Durham UTZ-xR1121C-FL (where x=2-5)100 1 Ov/Un 2-5 4/5 N 1,2

Durham UATZ-RS101C-FL125 1 Ov/Un 1 4/5 N 1,2 Al

Durham UTZ-RS101C-FL125 1 Ov/Un 1 4/5 N 1,2

Durham UAT-H4203x-FL (where x=B or T)200 1 Over 1 4 Y 1 Al

Durham UAT-H4213x-FL (where x=C or U)200 1 Ov/Un 1 4 Y 1 Al

Durham UAT-H5203x-FL (where x=B or T)200 1 Over 1 5 Y 3,3a Al

Durham UAT-H5213x-FL (where x=C or U)200 1 Ov/Un 1 5 Y 3,3a Al

Durham UAT-H7203x-FL (where x=B or T)200 3 Over 1 7 Y 4 Al

Durham UAT-H7213x-FL (where x=C or U)200 3 Ov/Un 1 7 Y 4 Al

Durham UAT-RS202B-FL200 1 Over 1 4/5 N 1,2 Al

Durham UAT-RS212C-FL200 1 Ov/Un 1 4/5 N 1,2 Al

Durham UAT-RS213A-FL200 1 Under 1 4/5 N 1,2 Al

Durham UAT-RS213C-FL200 1 Ov/Un 1 4/5 N 1,2 Al

Durham UAT-RS223A-FL200 1 Under 1 4/5 N 1,2 Al

Durham UT-4R2352U-FL200 1 Ov/Un 4 4/5 N 1,2

Durham UT-H4203x-FL (where x=B or T)200 1 Over 1 4 Y 1

Durham UT-H4213x-FL (where x=C or U)200 1 Ov/Un 1 4 Y 1

Durham UT-H5203x-FL (where x=B or T)200 1 Over 1 5 Y 3,3a

Durham UT-H5213x-FL (where x=C or U)200 1 Ov/Un 1 5 Y 3,3a

Durham UT-H7203x-FL (where x=B or T)200 3 Over 1 7 Y 4

Durham UT-H7213x-FL (where x=C or U)200 3 Ov/Un 1 7 Y 4

Durham UT-RS202B-FL200 1 Over 1 4/5 N 1,2

Durham UT-RS212C-FL200 1 Ov/Un 1 4/5 N 1,2

Durham UT-RS213A-FL200 1 Under 1 4/5 N 1,2

Durham UT-RS213C-FL200 1 Ov/Un 1 4/5 N 1,2

Durham UT-RS223A-FL200 1 Under 1 4/5 N 1,2

Durham UT-xR2332U-FL (where x=2-3)200 1 Ov/Un 2-3 4/5 N 1,2

Durham UT-xR2392UU-FL (where x=5-6)200 1 Ov/Un 5-6 4/5 N 1,2

Durham 1008836400 1 Ov/Un 1 4 Y 1

Durham 1008837400 1 Ov/Un 1 4 Y 1 Al

Durham UAT-H4300T-FL400 1 Over 1 4 Y 1 Al

Durham UAT-H5300T-FL400 1 Over 1 5 Y 3,3a Al

Durham UAT-H5330U-FL400 1 Ov/Un 1 5 Y 3,3a Al

Durham UAT-H7300T-FL400 3 Over 1 7 Y 4 Al

Durham UAT-H7330U-FL400 3 Ov/Un 1 7 Y 4 Al

Durham UT-H4300T-FL400 1 Over 1 4 Y 1

Durham UT-H5300T-FL400 1 Over 1 5 Y 3,3a

Durham UT-H5330U-FL400 1 Ov/Un 1 5 Y 3,3a

Durham UT-H7300T-FL400 3 Over 1 7 Y 4

Page 2 of 14

FPL - Florida Power Light PEF - Progress Energy-Florida TECO - Tampa Electric GULF - Gulf Power

© 2005, Florida Meter Group

Page 3: Florida Meter Approved Meter Equipment Group Enclosure List€¦ · served by the utilities of the Florida Meter Group. Approval is based on the unit's compliance with the FMG specifications,

Manufacturer Catalog NumberAmps Phase Service Pos Term Bypass Config

Approved Metering Equipment Enclosure List

Participants: FPL, GULF, PEF, TECO

Revised

4/6/2012

Durham UT-H7330U-FL400 3 Ov/Un 1 7 Y 4

Eaton-Cutler Hammer UTZ-6R1131C-FLCH100 1 Ov/Un 6 4/5 N 1,2

Eaton-Cutler Hammer UTZ-xR1121C-FLCH (where x=2-5)100 1 Ov/Un 2-5 4/5 N 1,2

Eaton-Cutler Hammer 1MMx12RRL or RRLC (where x=3-6)125 1 Ov/Un 3-6 4 N 1,2

Eaton-Cutler Hammer 1MP2122RRL or RRLC125 1 Ov/Un 2 4 N 1,2

Eaton-Cutler Hammer 1MPx124RRL or RRLC (where x=3-4)125 1 Ov/Un 3 4 N 1,2

Eaton-Cutler Hammer 1MPx126RRL or RRLC (where x=5-6)125 1 Ov/Un 5-6 4 N 1,2

Eaton-Cutler Hammer 3MMx12RRL or RRLC (where x=2-6)125 3 Ov/Un 2-6 4 N 1,2

Eaton-Cutler Hammer CHR (POWER OUTLET PANEL) 125 1 Ov/Un 1 4 N 1,2

Eaton-Cutler Hammer CMB24L125BTS FLCH125 1 Ov/Un 1 4/5 N 1,2

Eaton-Cutler Hammer MB24L125BTS FLCH125 1 Ov/Un 1 4/5 N 1,2

Eaton-Cutler Hammer UATZ-RS101C-FLCH125 1 Ov/Un 1 4/5 N 1,2 Al

Eaton-Cutler Hammer UTZ-RS101C-FLCH125 1 Ov/Un 1 4/5 N 1,2

Eaton-Cutler Hammer CMB88B150BTS FLCH150 1 Ov/Un 1 4 N 1,2

Eaton-Cutler Hammer CMBB150BTS FLCH150 1 Ov/Un 1 4/5 N 1,2

Eaton-Cutler Hammer MB816B150BTS FLCH150 1 Ov/Un 1 4 N 1,2

Eaton-Cutler Hammer MBB150BTS FLCH150 1 Ov/Un 1 4 N 1,2

Eaton-Cutler Hammer MBT48B150BTS150 1 Ov/Un 1 4/5 N 1,2

Eaton-Cutler Hammer 1MMx20RRL or RRLC (where x=3-4)200 1 Ov/Un 3-4 4/5 N 3,3a

Eaton-Cutler Hammer 1MP2204RRL or RRLC200 1 Ov/Un 2-6 4 N 1,2

Eaton-Cutler Hammer 1MPx206RRL or RRLC (where x=3-6)200 1 Ov/Un 2-6 4 N 1,2

Eaton-Cutler Hammer 3MMx20RRL or RRLC or R12RL (where x=2-4)200 1 Ov/Un 2-4 5 N 3,3a

Eaton-Cutler Hammer CMB1212B200BTS FLCH200 1 Ov/Un 1 4/5 N 1

Eaton-Cutler Hammer CMB1212L200BTS200 1 Ov/Un 1 4 N 1,2

Eaton-Cutler Hammer CMB1212P200BTS FLCH200 1 Ov/Un 1 4 N 1,2

Eaton-Cutler Hammer CMB4242B200BTS FLCH200 1 Ov/Un 1 4 N 1,2

Eaton-Cutler Hammer CMB88B200BTS FLCH200 1 Ov/Un 1 4 N 1,2

Eaton-Cutler Hammer CMBB200BTS FLCH200 1 Ov/Un 1 4 N 1,2

Eaton-Cutler Hammer CMBP200BTS FLCH200 1 Ov/Un 1 4 N 1,2

Eaton-Cutler Hammer MB1212L200BTS200 1 Ov/Un 1 4/5 N 1,2

Eaton-Cutler Hammer MB1212L200BTSA200 1 Ov/Ln 1 4/5 N 1,2 Al

Eaton-Cutler Hammer MB2040B200BTS FLCH200 1 Ov/Un 1 4 N 1,2

Eaton-Cutler Hammer MB2040P200BTS FLCH200 1 Ov/Un 1 4/5 N 1

Eaton-Cutler Hammer MB48B200BTS FLCH200 1 Ov/Un 1 4 N 1,2

Eaton-Cutler Hammer MB816B200BTS FLCH200 1 Ov/Un 1 4 N 1,2

Eaton-Cutler Hammer MB816P200BTS FLCH or BTSCU FLCH200 1 Ov/Un 1 4/5 N 1

Eaton-Cutler Hammer MBB200BTS FLCH200 1 Ov/Un 1 4 N 1,2

Eaton-Cutler Hammer MBP200BTS FLCH200 1 Ov/Un 1 4 N 1,2

Eaton-Cutler Hammer MBT48B200BTS200 1 Ov/Un 1 4/5 N 1,2

Page 3 of 14

FPL - Florida Power Light PEF - Progress Energy-Florida TECO - Tampa Electric GULF - Gulf Power

© 2005, Florida Meter Group

Page 4: Florida Meter Approved Meter Equipment Group Enclosure List€¦ · served by the utilities of the Florida Meter Group. Approval is based on the unit's compliance with the FMG specifications,

Manufacturer Catalog NumberAmps Phase Service Pos Term Bypass Config

Approved Metering Equipment Enclosure List

Participants: FPL, GULF, PEF, TECO

Revised

4/6/2012

Eaton-Cutler Hammer MC1212L200BTSA200 1 Ov/Un 1 4/5 N 1,2 Al

Eaton-Cutler Hammer UAT-H4203x-FLCH (where x=B or T)200 1 Over 1 4 Y 1 Al

Eaton-Cutler Hammer UAT-H5203x-FLCH (where x=B or T)200 1 Over 1 5 Y 3,3a Al

Eaton-Cutler Hammer UAT-H7203x-FLCH (where x=B or T)200 3 Over 1 7 Y 4 Al

Eaton-Cutler Hammer UAT-RS202B-FLCH200 1 Over 1 4/5 N 1,2 Al

Eaton-Cutler Hammer UAT-RS212C-FLCH200 1 Ov/Un 1 4/5 N 1,2 Al

Eaton-Cutler Hammer UAT-RS213A-FLCH200 1 Under 1 4/5 N 1,2 Al

Eaton-Cutler Hammer UAT-RS213C-FLCH200 1 Ov/Un 1 4/5 N 1,2 Al

Eaton-Cutler Hammer UAT-RS223A-FLCH200 1 Under 1 4/5 N 1,2 Al

Eaton-Cutler Hammer UAT-xR2332U-FLCH (where x=2-3)200 1 Ov/Un 2-3 4/5 N 1,2

Eaton-Cutler Hammer UAT-y4213x-FLCH (where y=E or H, where x=C or U)200 1 Ov/Un 1 4 Y 1 Al

Eaton-Cutler Hammer UAT-y5213x-FLCH (where y=E or H, where x=C or U)200 1 Ov/Un 1 5 Y 3,3a Al

Eaton-Cutler Hammer UAT-y7213x-FLCH (where y=E or H, where x=C or U)200 3 Ov/Un 1 7 Y 4 Al

Eaton-Cutler Hammer UT-4R2352U-FLCH200 1 Ov/Un 4 4/5 N 1,2

Eaton-Cutler Hammer UT-Hy203x-FLCH (where y=E or H, where x=B or T )200 3 Over 1 7 Y 4

Eaton-Cutler Hammer UT-RS202B-FLCH200 1 Over 1 4/5 N 1,2

Eaton-Cutler Hammer UT-RS212C-FLCH200 1 Ov/Un 1 4/5 N 1,2

Eaton-Cutler Hammer UT-RS213A-FLCH200 1 Under 1 4/5 N 1,2

Eaton-Cutler Hammer UT-RS213C-FLCH200 1 Ov/Un 1 4/5 N 1,2

Eaton-Cutler Hammer UT-RS223A-FLCH200 1 Under 1 4/5 N 1,2

Eaton-Cutler Hammer UT-xR2332U-FLCH (where x=2-3)200 1 Ov/Un 2-3 4/5 N 1,2

Eaton-Cutler Hammer UT-xR2392UU-FLCH (where x=5-6)200 1 Ov/Un 5-6 4/5 N 1,2

Eaton-Cutler Hammer UT-y4203x-FLCH (where y=E or H, where x=B or T )200 1 Over 1 4 Y 1

Eaton-Cutler Hammer UT-y4213x-FLCH (where y=E or H, where x=C or U200 1 Ov/Un 1 4 Y 1

Eaton-Cutler Hammer UT-y5203x-FLCH (where y=E or H, where x=B or T )200 1 Over 1 5 Y 3,3a

Eaton-Cutler Hammer UT-y5213x-FLCH (where y=E or H, where x=C or U)200 1 Ov/Un 1 5 Y 3,3a

Eaton-Cutler Hammer UT-y7213x-FLCH (where y=E or H, where x=C or U)200 3 Ov/Un 1 7 Y 4

Eaton-Cutler Hammer 35MMx20R12 (where x=1-4)225 1 Ov/Un 1-4 5 Y 3,3a

Eaton-Cutler Hammer 37MMx20R12 (where x=1-4)225 3 Ov/Un 1 7 Y 4

Eaton-Cutler Hammer 1008836x (where x = CH or ECH)400 1 Ov/Un 1 4 Y 1

Eaton-Cutler Hammer 1008837x (where x = CH or ECH)400 1 Ov/Un 1 4 Y 1 Al

Eaton-Cutler Hammer 35MM140R1240400 1 Under 1 5 Y 3

Eaton-Cutler Hammer 35MM240R1240400 1 Under 1 5 Y 3

Eaton-Cutler Hammer 37MM140R1240400 3 Under 1 7 Y 4

Eaton-Cutler Hammer 37MM240R1240400 3 Under 1 7 Y 4

Eaton-Cutler Hammer CG1212P400BSL400 1 Under 1 4 Y 1,2

Eaton-Cutler Hammer CG404242SHL400 1 Under 1 4 Y 1,2

Eaton-Cutler Hammer CG40SHL400 1 Under 1 4 Y 1,2

Eaton-Cutler Hammer HP404040SHL400 1 Under 1 4 Y 1,2

Page 4 of 14

FPL - Florida Power Light PEF - Progress Energy-Florida TECO - Tampa Electric GULF - Gulf Power

© 2005, Florida Meter Group

Page 5: Florida Meter Approved Meter Equipment Group Enclosure List€¦ · served by the utilities of the Florida Meter Group. Approval is based on the unit's compliance with the FMG specifications,

Manufacturer Catalog NumberAmps Phase Service Pos Term Bypass Config

Approved Metering Equipment Enclosure List

Participants: FPL, GULF, PEF, TECO

Revised

4/6/2012

Eaton-Cutler Hammer HP40SHL400 1 Under 1 4 Y 1,2

Eaton-Cutler Hammer HP816Px00BSL (where x = 3 or 4)400 1 Under 1 4 Y 1,2

Eaton-Cutler Hammer UATH4330TFLCH400 1 Ov/Un 1 4 Y 1 Al

Eaton-Cutler Hammer UAT-y4300T-FLCH (where y=E or H)400 1 Over 1 4 Y 1 Al

Eaton-Cutler Hammer UAT-y5300T-FLCH (where y=E or H)400 1 Over 1 5 Y 3,3a Al

Eaton-Cutler Hammer UAT-y5330U-FLCH (where y=E or H)400 1 Ov/Un 1 5 Y 3,3a Al

Eaton-Cutler Hammer UAT-y7300T-FLCH (where y=E or H)400 3 Over 1 7 Y 4 Al

Eaton-Cutler Hammer UAT-y7330U-FLCH (where y=E or H)400 3 Ov/Un 1 7 Y 4 Al

Eaton-Cutler Hammer UTH4330TFLCH400 1 Ov/Un 1 4 Y 1

Eaton-Cutler Hammer UT-y4300T-FLCH (where y=E or H)400 1 Over 1 4 Y 1

Eaton-Cutler Hammer UT-y5300T-FLCH (where y=E or H)400 1 Over 1 5 Y 3,3a

Eaton-Cutler Hammer UT-y5330U-FLCH (where y=E or H)400 1 Ov/Un 1 5 Y 3,3a

Eaton-Cutler Hammer UT-y7300T-FLCH (where y=E or H)400 3 Over 1 7 Y 4

Eaton-Cutler Hammer UT-y7330U-FLCH (where y=E or H)400 3 Ov/Un 1 7 Y 4

Eaton-Cutler Hammer CH9526K7 (Requires Ridged Lugs) FPL ONLY600 3 Ov/Un 1 7 Y 5

Eaton-Cutler Hammer CH9527K7 (Requires Ridged Lugs) FPL ONLY600 3 Ov/Un 1 7 Y 5 Al

Elec.Prod. RVPD-xxxx-FPL100 1 Under 2 4 N 1

Elec.Prod. RVP-xxxx-FPL100 1 Under 1 4 N 1

Elec.Prod. MHPD-xxxx-FPL200 1 Under 2 4 N 1

Elec.Prod. MHP-xxxx-FPL200 1 Under 1 4 N 1

Emerson MESBGFXLW11FBZ1125 1 Under 1 5 Y 3a

Emerson MESBGFXLW11FBZ1P125 1 Under 1 5 Y 3a

Emerson MESBGFXLW11KBZ1125 1 Under 1 5 Y 3a

Emerson MESBGFXLW11KBZ1P125 1 Under 1 5 Y 3a

Emerson MESBAATLW11FBZ1200 1 Under 1 5 Y 3a

Emerson MESBAATLW11FBZ1P200 1 Under 1 5 Y 3a

Emerson MESBAATLW11KBZ1200 1 Under 1 5 Y 3a

Emerson MESBAATLW11KBZ1P200 1 Under 1 5 Y 3a

General Electric TM10RMCFMG100 1 Ov/Un 1 4 N 1

General Electric TM12RMCFMG125 1 Ov/Un 1 4 N 1

General Electric TMMR2212R125 1 Under 2 4/5 N 1,2

General Electric TMMR4x12R (where x=3-4)125 1 Under 3-4 4/5 N 1,2

General Electric TMMR6x12R (where x=5-6)125 1 Under 5-6 4/5 N 1,2

General Electric TMPR8x12R (where x=2-6)125 1 Under 2-6 4/5 N 1,2

General Electric TM15RMCFMG150 1 Ov/Un 1 4 N 1

General Electric TSMF415CSFL150 1 Ov/Un 1 4/5 N 1,2

General Electric TSMF815CSFL150 1 Ov/Un 1 4/5 N 1,2

General Electric TSMR415CSFLFMG150 1 Ov/Un 1 4 N 1

General Electric TSMR815CSFLFMG150 1 Ov/Un 1 4 N 1

Page 5 of 14

FPL - Florida Power Light PEF - Progress Energy-Florida TECO - Tampa Electric GULF - Gulf Power

© 2005, Florida Meter Group

Page 6: Florida Meter Approved Meter Equipment Group Enclosure List€¦ · served by the utilities of the Florida Meter Group. Approval is based on the unit's compliance with the FMG specifications,

Manufacturer Catalog NumberAmps Phase Service Pos Term Bypass Config

Approved Metering Equipment Enclosure List

Participants: FPL, GULF, PEF, TECO

Revised

4/6/2012

General Electric TM20RMCFMG200 1 Ov/Un 1 4 N 1

General Electric TMMR4x20R (where x=2-6)200 1 Ov/Un 2-6 4 N 1,2

General Electric TMMR6x20R (where x=3-6)200 1 Under 3-6 4/5 N 1,2

General Electric TMPR312x22R (where x=1-4)200 3 Ov/Un 1-4 7 Y 4

General Electric TMPR8x20R (where x=2-4)200 1 Under 2-4 4/5 N 1,2

General Electric TSLR1220FSAL200 1 Ov/Un 1 4 N 1, Al

General Electric TSMF420CSFL200 1 Ov/Un 1 4/5 N 1,2

General Electric TSMF820CSFL200 1 Ov/Un 1 4/5 N 1,2

General Electric TSMR2020CSCUFMG200 1 Ov/Un 1 4 N 1

General Electric TSMRx20CSFLFMG (where x = 4 or 8)200 1 Ov/Un 1 4 N 1

General Electric TMPR12x22R (where x=1-4)225 1 Ov/Un 1-4 5 Y 3,3a

General Electric TMPR1240RB400 1 Ov/Un 1 5 Y 3,3a

General Electric TMPR31240RB400 3 Ov/Un 1 7 Y 4

General Electric TSDR840USCU400 1 Under 1 4/5 Y 1,2

Landis & Gyr/TALON UAT111-XGF100 1 Over 1 4/5 N 1

Landis & Gyr/TALON UAT131-XGF100 1 Over 1 4/5 N 1 Al

Landis & Gyr/TALON UAT111-OGF125 1 Over 1 4 N 1

Landis & Gyr/TALON 40005-01F200 1 Over 1 5 Y 3,3a

Landis & Gyr/TALON 40007-01F200 3 Over 1 7 Y 4

Landis & Gyr/TALON 40405-015F200 1 Ov/Un 1 5 Y 3,3a

Landis & Gyr/TALON 40405-025F200 1 Ov/Un 1 5 Y 3,3a

Landis & Gyr/TALON 40407-015F200 3 Ov/Un 1 7 Y 4

Landis & Gyr/TALON 40407-025F200 3 Ov/Un 1 7 Y 4

Landis & Gyr/TALON 41005-01F200 1 Over 1 5 Y 3,3a

Landis & Gyr/TALON 41007-01F200 3 Over 1 7 Y 4 Al

Landis & Gyr/TALON 41405-025F200 1 Ov/Un 1 5 Y 3,3a Al

Landis & Gyr/TALON 41407-025F200 3 Ov/Un 1 7 Y 4 Al

Landis & Gyr/TALON LG0408B1200RT200 1 Ov/Un 1 4 N 1

Landis & Gyr/TALON LG0606L1200R or RA200 1 Ov/Un 1 4/5 N 1, 1 Al

Landis & Gyr/TALON UA27x6-ZGF (where x=1 or 3)200 1 Ov/Un 2 1 N 1, 1 Al

Landis & Gyr/TALON UA37x7-ZGF (where x=1 or 3)200 1 Ov/Un 3 1 N 1, 1 Al

Landis & Gyr/TALON UA47x9-ZGF (where x=1 or 3)200 1 Ov/Un 4 1 N 1, 1 Al

Landis & Gyr/TALON UA57x9-MGF (where x=1 or 3)200 1 Ov/Un 5 1 N 1, 1 Al

Landis & Gyr/TALON UA67x9-MGF (where x=1 or 3)200 1 Ov/Un 6 1 N 1, 1 Al

Landis & Gyr/TALON UAT317-OGF200 1 Over 1 4/5 N 1

Landis & Gyr/TALON UAT337-OGF200 1 Over 1 4/5 N 1 Al

Landis & Gyr/TALON UAT417-PGF200 1 Under 1 4/5 N 1,2

Landis & Gyr/TALON UAT417-XGF200 1 Ov/Un 1 4/5 N 1,2

Landis & Gyr/TALON UAT437-PGF200 1 Under 1 4/5 N 1 Al

Page 6 of 14

FPL - Florida Power Light PEF - Progress Energy-Florida TECO - Tampa Electric GULF - Gulf Power

© 2005, Florida Meter Group

Page 7: Florida Meter Approved Meter Equipment Group Enclosure List€¦ · served by the utilities of the Florida Meter Group. Approval is based on the unit's compliance with the FMG specifications,

Manufacturer Catalog NumberAmps Phase Service Pos Term Bypass Config

Approved Metering Equipment Enclosure List

Participants: FPL, GULF, PEF, TECO

Revised

4/6/2012

Landis & Gyr/TALON UAT437-XGF200 1 Ov/Un 1 4/5 N 1 Al

Landis & Gyr/TALON 41105-02FL400 1 Ov/Un 1 5 Y 3,3a Al

Landis & Gyr/TALON 44707-02FL400 3 Ov/Un 1 7 Y 4

Landis & Gyr/TALON 47705-02FL400 1 Ov/Un 1 5 Y 3,3a

Landis & Gyr/TALON 49005-02FL400 1 Ov/Un 1 5 Y 3,3a

Landis & Gyr/TALON 49007-02FL400 3 Ov/Un 1 7 Y 4

Landis & Gyr/TALON 49105-02FL400 1 Ov/Un 1 5 Y 3,3a Al

Landis & Gyr/TALON 49107-02FL400 3 Ov/Un 1 7 Y 4 Al

Landis & Gyr/TALON 9817-8061 FPL Only400 3 Under 3 7 N 4

Landis & Gyr/TALON 9817-8062 FPL Only400 3 Under 3 7 N 4 Al

Landis & Gyr/TALON 9817-9526 (Requires Ridged Lugs) FPL ONLY600 3 Ov/Un 1 7 Y 5

Landis & Gyr/TALON 9817-9527 (Requires Ridged Lugs) FPL ONLY600 3 Ov/Un 1 7 Y 5 Al

Midwest M0xxC010-FMG (where xx=32,36,38,41,51,55,76)100 1 Over 1 4/5 N 1,2

Midwest M0xxC010U-FMG (where xx=32,36,38,41,51,55,76)100 1 Under 1 4/5 N 1,2

Midwest M0xxC033-FMG (where xx=32,36,38,41,51,55,76)100 1 Over 1 4/5 N 1,2

Midwest M0xxC033U-FMG (where xx=32,36,38,41,51,55,76)100 1 Under 1 4/5 N 1,2

Midwest UTZ-6R1131C-FLMEP100 1 Ov/Un 6 4/5 N 1,2

Midwest UTZ-xR1121C-FLMEP (where x=2-5)100 1 Ov/Un 2-5 4/5 N 1,2

Midwest UATZ-RS101C-FLMEP125 1 Ov/Un 1 4/5 N 1,2 Al

Midwest UTZ-RS101C-FLMEP125 1 Ov/Un 1 4/5 N 1,2

Midwest R158CR2TLFMG150 1 Ov/Un 1 4 N 1

Midwest MPx00S0FMG (where x=1-4)200 1 Under 1-4 4/5 N 1,2 Al

Midwest MPx00S1FMG (where x=1-4)200 1 Under 1-4 4/5 N 1,2 Al

Midwest MPx20B0FMG (where x=1-4)200 1 Under 1-4 4/5 N 1,2 Al

Midwest MPx20B1FMG (where x=1-4)200 1 Under 1-4 4/5 N 1,2 Al

Midwest PM5x220B0FMG (where x=1-4)200 1 Under 1-4 4/5 N 1,2 Al

Midwest R208CR2TLFMG200 1 Ov/Un 1 4 N 1

Midwest R256EB118FMG200 1 Ov/Un 1 4 N 1, Al

Midwest R256EB1FMG200 1 Ov/Un 1 4 N 1

Midwest R256EB1NFMG200 1 Ov/Un 1 4 N 1

Midwest UAT-H4203x-FLMEP (where x=B or T)200 1 Over 1 4 Y 1 Al

Midwest UAT-H4213x-FLMEP (where x=C or U)200 1 Ov/Un 1 4 Y 1 Al

Midwest UAT-H5203x-FLMEP (where x=B or T)200 1 Over 1 5 Y 3,3a Al

Midwest UAT-H5213x-FLMEP (where x=C or U)200 1 Ov/Un 1 5 Y 3,3a Al

Midwest UAT-H7203x-FLMEP (where x=B or T)200 3 Over 1 7 Y 4 Al

Midwest UAT-H7213x-FLMEP (where x=C or U)200 3 Ov/Un 1 7 Y 4 Al

Midwest UAT-RS202B-FLMEP200 1 Over 1 4/5 N 1,2 Al

Midwest UAT-RS212C-FLMEP200 1 Ov/Un 1 4/5 N 1,2 Al

Midwest UAT-RS213A-FLMEP200 1 Under 1 4/5 N 1,2 Al

Page 7 of 14

FPL - Florida Power Light PEF - Progress Energy-Florida TECO - Tampa Electric GULF - Gulf Power

© 2005, Florida Meter Group

Page 8: Florida Meter Approved Meter Equipment Group Enclosure List€¦ · served by the utilities of the Florida Meter Group. Approval is based on the unit's compliance with the FMG specifications,

Manufacturer Catalog NumberAmps Phase Service Pos Term Bypass Config

Approved Metering Equipment Enclosure List

Participants: FPL, GULF, PEF, TECO

Revised

4/6/2012

Midwest UAT-RS213C-FLMEP200 1 Ov/Un 1 4/5 N 1,2 Al

Midwest UAT-RS223A-FLMEP200 1 Under 1 4/5 N 1,2 Al

Midwest UT-4R2352U-FLMEP200 1 Ov/Un 4 4/5 N 1,2

Midwest UT-H4203x-FLMEP (where x=B or T)200 1 Over 1 4 Y 1

Midwest UT-H4213x-FLMEP (where x=C or U)200 1 Ov/Un 1 4 Y 1

Midwest UT-H5203x-FLMEP (where x=B or T)200 1 Over 1 5 Y 3,3a

Midwest UT-H5213x-FLMEP (where x=C or U)200 1 Ov/Un 1 5 Y 3,3a

Midwest UT-H7203x-FLMEP (where x=B or T)200 3 Over 1 7 Y 4

Midwest UT-H7213x-FLMEP (where x=C or U)200 3 Ov/Un 1 7 Y 4

Midwest UT-RS202B-FLMEP200 1 Over 1 4/5 N 1,2

Midwest UT-RS212C-FLMEP200 1 Ov/Un 1 4/5 N 1,2

Midwest UT-RS213A-FLMEP200 1 Under 1 4/5 N 1,2

Midwest UT-RS213C-FLMEP200 1 Ov/Un 1 4/5 N 1,2

Midwest UT-RS223A-FLMEP200 1 Under 1 4/5 N 1,2

Midwest UT-xR2332U-FLMEP (where x=2-3)200 1 Ov/Un 2-3 4/5 N 1,2

Midwest UT-xR2392UU-FLMEP (where x=5-6)200 1 Ov/Un 5-6 4/5 N 1,2

Midwest 1008836MEP400 1 Ov/Un 1 4 Y 1

Midwest 1008837MEP400 1 Ov/Un 1 4 Y 1 Al

Midwest RS455***FMG400 1 Under 1 4/5 Y 1,2

Midwest UAT-H4300T-FLMEP400 1 Over 1 4 Y 1 Al

Midwest UAT-H5300T-FLMEP400 1 Over 1 5 Y 3,3a Al

Midwest UAT-H5330U-FLMEP400 1 Ov/Un 1 5 Y 3,3a Al

Midwest UAT-H7300T-FLMEP400 3 Over 1 7 Y 4 Al

Midwest UAT-H7330U-FLMEP400 3 Ov/Un 1 7 Y 4 Al

Midwest UT-H4300T-FLMEP400 1 Over 1 4 Y 1

Midwest UT-H5300T-FLMEP400 1 Over 1 5 Y 3,3a

Midwest UT-H5330U-FLMEP400 1 Ov/Un 1 5 Y 3,3a

Midwest UT-H7300T-FLMEP400 3 Over 1 7 Y 4

Midwest UT-H7330U-FLMEP400 3 Ov/Un 1 7 Y 4

Milbank U349y-XL-HSP (where y=2-6)100 1 Ov/Un 2-6 4/5 N 1,2

Milbank U513y-O-100P-FMG (where y=6-7)100 1 Un-Ped 1-2 4/5 N 1,2

Milbank U513y-O-100S-FMG (where y=6-7)100 1 Un-Ped 1-2 4/5 N 1,2

Milbank UAP349y-XL-HSP (where y=2-6)100 1 Ov/Un 2-6 4/5 N 1,2 Al

Milbank U285y-X-HSP (where y=2-6)125 1 Ov/Un 2-6 4/5 N 1,2

Milbank U3505-XL-HSP125 1 Ov/Un 1 5 Y 3,3a

Milbank U3505-XL-TG-HSP125 1 Ov/Un 1 5 Y 3,3a

Milbank U3506-XL-TG-HSP125 3 Ov/Un 1 7 Y 4

Milbank U513y-O-125P-FMG (where y=6-7)125 1 Under 1-2 4/5 N 1,2

Milbank U513y-O-125S-FMG (where y=6-7)125 1 Under 1-2 4/5 N 1,2

Page 8 of 14

FPL - Florida Power Light PEF - Progress Energy-Florida TECO - Tampa Electric GULF - Gulf Power

© 2005, Florida Meter Group

Page 9: Florida Meter Approved Meter Equipment Group Enclosure List€¦ · served by the utilities of the Florida Meter Group. Approval is based on the unit's compliance with the FMG specifications,

Manufacturer Catalog NumberAmps Phase Service Pos Term Bypass Config

Approved Metering Equipment Enclosure List

Participants: FPL, GULF, PEF, TECO

Revised

4/6/2012

Milbank U8435-XL-TG-HSP125 1 Over 1 4/5 N 1,2

Milbank UAP3505-XL-TG-HSP125 1 Ov/Un 1 5 Y 3,3a Al

Milbank UAP3506-XL-TG-HSP125 3 Ov/Un 1 7 Y 4 Al

Milbank UAP8435-XL-TG-HSP125 1 Ov/Un 1 4/5 N 1,2 Al

Milbank U123y-X-HSP (where y=2-6)150 1 Ov/Un 2-6 4/5 N 1,2

Milbank U3312-XL-TG-HSP150 1 Ov/Un 1 4/5 N 1,2

Milbank U513y-O-150P-FMG (where y=6-7)150 1 Under 1-2 4/5 N 1,2

Milbank U513y-O-150S-FMG (where y=6-7)150 1 Under 1-2 4/5 N 1,2

Milbank UAP123y-X-HSP (where y=2-3)150 1 Ov/Un 2-3 4/5 N 1,2 Al

Milbank U125Y-X-HSP (where y=2-6)200 1 Ov/Un 2-6 4/5 N 1,2

Milbank U1980-O-HSP200 1 Under 1 4/5 N 1,2

Milbank U273y-XT-HSP (where y=2-6)200 3 Ov/Un 2-6 7 Y 4

Milbank U286y-X-HSP (where y=2-6)200 1 Ov/Un 2-6 4/5 N 1,2

Milbank U287y-XT-HSP (where y=2-6)200 1 Ov/Un 2-6 5 Y 3,3a

Milbank U3296-X-HSP200 1 Ov/Un 1 5 Y 3,3a

Milbank U3306-X-HSP200 3 Ov/Un 1 7 Y 4

Milbank U3850-XL-TG-HSP-PL200 1 Ov/Un 1 4/5 N 1,2

Milbank U5136-O-yyy-FMG (where yyy=41,55,75,332,552)200 1 Un-Ped 1 4/5 N 1,2

Milbank U5137-O-yyy-FMG (where yyy=41,55,75,332,552)200 1 Un-Ped 2 4/5 N 1,2

Milbank U513y-O-200P-FMG (where y=6-7)200 1 Un-Ped 1-2 4/5 N 1,2

Milbank U513y-O-200S-FMG (where y=6-7)200 1 Un-Ped 1-2 4/5 N 1,2

Milbank U513y-O-FMG (where y=6-7)200 1 Un-Ped 1-2 4/5 N 1,2

Milbank U7021-RL-TG-HSP200 1 Over 1 4/5 N 1,2

Milbank U7040-O-TG-HSP200 1 Under 1 4 N 1,2

Milbank U7040-XL-TG-HSP200 1 Ov/Un 1 4/5 N 1,2

Milbank U7043-XL-TG200 1 Ov/Un 1 4/5 N 1,2

Milbank U9550-RRL-QG-HSP200 1 Over 1 5 Y 3,3a

Milbank U9551-X-QG-HSP200 1 Ov/Un 1 5 Y 3,3a

Milbank U9700-RRL-QG-HSP200 3 Over 1 7 Y 4

Milbank U9701-X-QG-HSP200 3 Ov/Un 1 7 Y 4

Milbank U9801-X-QG -HSP200 1 Ov/Un 1 4 Y 1,2

Milbank UAP125y-X-HSP (where y=2-6)200 1 Ov/Un 2-6 4/5 Y 1,2 Al

Milbank UAP1980-O-HSP200 1 Under 1 4/5 N 1,2 Al

Milbank UAP3296-X-HSP200 1 Ov/Un 1 5 Y 3,3a Al

Milbank UAP3306-X-HSP200 3 Ov/Un 1 7 Y 4 Al

Milbank UAP5024-XL200 1 Ov/Un 1 4 N 1

Milbank UAP5024-XL-FMG200 1 Ov/Un 1 4 N 1

Milbank UAP7021-RL-TG-HSP200 1 Over 1 4/5 N 1,2 Al

Milbank UAP7040-O-TG-HSP200 1 Under 1 4/5 N 1,2 Al

Page 9 of 14

FPL - Florida Power Light PEF - Progress Energy-Florida TECO - Tampa Electric GULF - Gulf Power

© 2005, Florida Meter Group

Page 10: Florida Meter Approved Meter Equipment Group Enclosure List€¦ · served by the utilities of the Florida Meter Group. Approval is based on the unit's compliance with the FMG specifications,

Manufacturer Catalog NumberAmps Phase Service Pos Term Bypass Config

Approved Metering Equipment Enclosure List

Participants: FPL, GULF, PEF, TECO

Revised

4/6/2012

Milbank UAP7040-XL-TG-HSP200 1 Ov/Un 1 4/5 N 1,2 Al

Milbank UAP9550-RRL-QG-HSP200 1 Over 1 5 Y 3,3a Al

Milbank UAP9551-X-QG-HSP200 1 Ov/Un 1 5 Y 3,3a Al

Milbank UAP9700-RRL-QG-HSP200 3 Over 1 7 Y 4 Al

Milbank UAP9701-X-QG-HSP200 3 Ov/Un 1 7 Y 4 Al

Milbank U2120-O-HSP400 3 Ov/Un 1 7 Y 4

Milbank U2120-X-HSP400 3 Under 1 7 Y 4

Milbank U2124-O-HSP400 1 Under 1 4/5 Y 4

Milbank U3313-X-HSP400 1 Ov/Un 1 5 Y 3,3a

Milbank U3566-X-HSP400 3 Ov/Un 1 7 Y 4

Milbank U3949-X-HSP400 1 Over 1 5 Y 3,3a

Milbank U5864-X-HSP400 1 Ov/Un 1 5 Y 3, 3a

Milbank U5864-X-HSP400 1 Ov/Un 1 5 Y 3, 3a

Milbank UAP2124-O-HSP400 1 Under 1 4/5 Y 4 Al

Milbank UAP3313-X-HSP400 1 Ov/Un 1 5 Y 3,3a Al

Milbank UAP3566-X-HSP400 3 Ov/Un 1 7 Y 4 Al

Milbank UAP3949-X-HSP400 1 Over 1 5 Y 3,3a Al

Milbank UAP5864-X-HSP400 1 Ov/Un 1 5 Y 3, 3a Al

Milbank U4667-X-8528 (Req. Ridged Lugs) FPL ONLY600 3 Ov/Un 1 7 Y 5

Milbank U4667-XT-9526(Requires Ridged Lugs) FPL ONLY600 3 Ov/Un 1 7 Y 5

Milbank UA4667-X-8529 (Req. Ridged Lugs) FPL ONLY600 3 Ov/Un 1 7 Y 5 Al

Milbank UA4667-XT-9527(Requires Ridged Lugs) FPL ONLY600 3 Ov/Un 1 7 Y 5 Al

Murray RJ103AXF100 1 Over 1 4 N 1

Murray JA1224B1125125 1 Ov/Un 1 4/5 N 1,2

Murray JA0408B1150T or RT150 1 Ov/Un 1 4 N 1

Murray JA0816B1150CT or RCT150 1 Ov/Un 1 4 N 1

Murray JA0816B1150TH150 1 Ov/Un 1 4/5 N 1,2

Murray JA2040B1150150 1 Ov/Un 1 4/5 N 1,2

Murray JA2040B1150RC150 1 Ov/Un 1 4 N 1

Murray JA204LS150 1 Ov/Un 1 4/5 N 1,2

Murray JC0202B1150150 1 Ov/Un 1 4/5 N 1,2

Murray JA0408B1200T or RT200 1 Ov/Un 1 4 N 1

Murray JA0606L1200R or RA200 1 Ov/Un 1 4/5 N 1, 1 Al

Murray JA0816B1200CT or RCT200 1 Ov/Un 1 4 N 1

Murray JA0816B1200TH200 1 Ov/Un 1 4/5 N 1,2

Murray JA2040B1200200 1 Ov/Un 1 4/5 N 1,2

Murray JA2040B1200RC200 1 Ov/Un 1 4 N 1

Murray JA204TS200 1 Ov/Un 1 4/5 N 1,2

Murray JC0202B1200200 1 Ov/Un 1 4/5 N 1,2

Page 10 of 14

FPL - Florida Power Light PEF - Progress Energy-Florida TECO - Tampa Electric GULF - Gulf Power

© 2005, Florida Meter Group

Page 11: Florida Meter Approved Meter Equipment Group Enclosure List€¦ · served by the utilities of the Florida Meter Group. Approval is based on the unit's compliance with the FMG specifications,

Manufacturer Catalog NumberAmps Phase Service Pos Term Bypass Config

Approved Metering Equipment Enclosure List

Participants: FPL, GULF, PEF, TECO

Revised

4/6/2012

Murray RB103AR200 1 Ov/Un 1 4/5 N 1,2

Murray RH173CRF200 1 Ov/Un 1 5 Y 3,3a

Murray RH173GRF200 3 Ov/Un 1 7 Y 4

Murray RS103AVF200 1 Under 1 4/5 N 1,2

Murray RS103AXF200 1 Over 1 4 N 1

Murray JA0816B1350RLTM400 1 Ov/Un 1 4/5 Y 1,2

Murray JA0816B1400RLTM400 1 Ov/Un 1 4/5 Y 1,2

Murray JC0404L1400RLM400 1 Ov/Un 1 4/5 Y 1,2

Murray JC0408B1400RLTM400 1 Ov/Un 1 4/5 Y 1,2

Siemens WMLx3225RJ (where x=1-4)100 3 Under 1-4 7 Y 4

Siemens MC1224B1125125 1 Ov/Un 1 4/5 N 1,2

Siemens SPxx11RJ (where xx=22, 33, 44, 45, 46, 65, 66)125 1 Ov/Un 2-6 4/5 N 1,2

Siemens SUAT111-OGF125 1 Over 1 4 N 1

Siemens WMMx1125R (where x=2-6)125 1 Under 2-6 4 N 1,2

Siemens WMMx2125RJ (where x=2-6)125 3 Under 2-6 5 N 2

Siemens MC0408B1150T or RT150 1 Ov/Un 1 4 N 1

Siemens MC0408MB1150T150 1 Ov/Un 1 4/5 N 1,2

Siemens MC0816B1150CT or RCT150 1 Ov/Un 1 4 N 1

Siemens MC0816B1150TH150 1 Ov/Un 1 4/5 N 1,2

Siemens MC2040B1150150 1 Ov/Un 1 4/5 N 1,2

Siemens MC2040B1150RC150 1 Ov/Un 1 4 N 1

Siemens MM0202B1150150 1 Ov/Un 1 4/5 N 1,2 St

Siemens MC0408B1200T or RT200 1 Ov/Un 1 4 N 1

Siemens MC0408MB1200T200 1 Ov/Un 1 4/5 N 1,2

Siemens MC0606L1200R or RA200 1 Ov/Un 1 4/5 N 1, 1 Al

Siemens MC0816B1200CT or RCT200 1 Ov/Un 1 4 N 1

Siemens MC0816B1200TH200 1 Ov/Un 1 4/5 N 1,2

Siemens MC2040B1200200 1 Ov/Un 1 4/5 N 1,2

Siemens MC2040B1200RC200 1 Ov/Un 1 4 N 1

Siemens MM0202B1200200 1 Ov/Un 1 4/5 N 1,2 St

Siemens MM0406L1200H200 1 Ov/Un 1 4/5 N 1,2

Siemens S40405-015F200 1 Ov/Un 1 5 Y 3,3a

Siemens S40407-015F200 3 Ov/Un 1 7 Y 4

Siemens SPxx12RJ (where xx=42, 43, 44, 65, 66)200 1 Ov/Un 2-6 4/5 N 1,2

Siemens SUAT317-OGF200 1 Over 1 4 N 1

Siemens SUAT417-PGF200 1 Under 1 4/5 N 1,2

Siemens SUAT417-XGF200 1 Ov/Un 1 4/5 N 1,2

Siemens WMLx3200RJ (where x=1-4)200 3 Under 1-4 7 Y 4

Siemens WMMx1225R (where x=2-6)200 1 Under 2-6 4 N 3

Page 11 of 14

FPL - Florida Power Light PEF - Progress Energy-Florida TECO - Tampa Electric GULF - Gulf Power

© 2005, Florida Meter Group

Page 12: Florida Meter Approved Meter Equipment Group Enclosure List€¦ · served by the utilities of the Florida Meter Group. Approval is based on the unit's compliance with the FMG specifications,

Manufacturer Catalog NumberAmps Phase Service Pos Term Bypass Config

Approved Metering Equipment Enclosure List

Participants: FPL, GULF, PEF, TECO

Revised

4/6/2012

Siemens WMMx2225RJ (where x=2-6)200 3 Under 2-6 5 N 3a

Siemens WML1x225RJ (where x=1-4)225 1 Ov/Un 1-4 4 Y 3,3a

Siemens WMLx1225RJ (where x=2-6)225 1 Ov/Un 2-6 4 Y 3,3a

Siemens WMLx2yz225RJ (where x=2 or 4) (yz=AB, BC or CA)225 1 Ov/Un 2 or 4 5 Y 3, 3A

Siemens MC0408B1400RLTM400 1 Ov/Un 1 4/5 Y 1,2

Siemens MC0816B1350RLTM400 1 Ov/Un 1 4/5 Y 1,2

Siemens MC0816B1400RLTM400 1 Ov/Un 1 4/5 Y 1,2

Siemens MM0404L1400RLM400 1 Ov/Un 1 4/5 Y 1,2

Siemens S9817-8061 FPL Only400 3 Under 3 7 N 4

Siemens S9817-8062 FPL Only400 3 Under 3 7 N 4 Al

Siemens WMKxy400z where (x=1 or 2)(y=1-3)(z=R or RJ) FPL Only400 1 Under 1 4 Y 1

Siemens WMLxy400RJ where (x=1 or 2) (y=1-3) FPL Only400 1 Under 1 4 Y 1

Siemens WMKxy600z where (x=1 or 2)(y=1-3)(z=R or RJ) FPL Only600 1 Under 1 4 N 1

Square D UTZ-6R1131C-FLSQD100 1 Ov/Un 6 4/5 N 1,2

Square D UTZ-xR1121C-FLSQD (where x=2-5)100 1 Ov/Un 2-5 4/5 N 1,2

Square D EZMR11y125 (where y=3-6)125 1 Mtr Ctr 3-6 5 N 1,2

Square D EZMR11y125CU (where y=3-6)125 1 Mtr Ctr 3-6 5 N 1,2

Square D EZMR11y125X (where y=3-6)125 1 Mtr Ctr 3-6 5 N 1,2

Square D EZMR31y125 (where y=3-5)125 1 Mtr Ctr 3-5 5 N 1,2

Square D EZMR31y125CU (where y=3-5)125 1 Mtr Ctr 3-5 5 N 1,2

Square D EZMR31y125X (where y=3-5)125 1 Mtr Ctr 3 5 N 1,2

Square D MPRyy125 (where yy=22,33,44,55,66)125 1 Ov/Un 2-6 5 N 1,2

Square D UATZ-RS101C-FLSQD125 1 Ov/Un 1 4/5 N 1,2 Al

Square D UTZ-RS101C-FLSQD125 1 Ov/Un 1 4/5 N 1,2

Square D QC816F150C150 1 Ov/Un 1 4/5 N 1,2

Square D RC816F150C150 1 Ov/Un 1 4/5 N 1,2

Square D EZML11y200 (where y=1-4)200 1 Mtr Ctr 1-4 5 Y 1,2

Square D EZML31y200 (where y=2-4)200 1 Mtr Ctr 2-4 5 Y 3a

Square D EZML33y200 (where y=1-4)200 3 Mtr Ctr 1 7 Y 4

Square D EZMR11y200 (where y=2-4)200 1 Mtr Ctr 2-4 5 N 1,2

Square D EZMR11y200CU (where y=2-4)200 1 Mtr Ctr 2 5 N 1,2

Square D EZMR11y200X (where y=2-4)200 1 Mtr Ctr 2 5 N 1,2

Square D MPLyy200 (where yy=32,43,64)200 1 Ov/Un 2-4 5 Y 3

Square D MPR4y200 (where y=2-3)200 1 Ov/Un 2-3 5 N 1,2

Square D MPR64200200 1 Ov/Un 4 5 N 1,2

Square D MPR8y200 (where y=5-6)200 1 Ov/Un 5-6 5 N 1,2

Square D QC12L200C200 1 Ov/Un 1 4/5 N 1,2

Square D QC2442M200C200 1 Ov/Un 1 4/5 Y/N 1,2

Square D QC816F200C200 1 Ov/Un 1 4/5 N 1,2

Page 12 of 14

FPL - Florida Power Light PEF - Progress Energy-Florida TECO - Tampa Electric GULF - Gulf Power

© 2005, Florida Meter Group

Page 13: Florida Meter Approved Meter Equipment Group Enclosure List€¦ · served by the utilities of the Florida Meter Group. Approval is based on the unit's compliance with the FMG specifications,

Manufacturer Catalog NumberAmps Phase Service Pos Term Bypass Config

Approved Metering Equipment Enclosure List

Participants: FPL, GULF, PEF, TECO

Revised

4/6/2012

Square D RC12L200C200 1 Ov/Un 1 4/5 N 1,2

Square D RC2040M200C200 1 Ov/Un 1 4/5 N 1,2

Square D RC816F200C200 1 Ov/Un 1 4/5 N 1,2

Square D UAT-H4203x-FLSQD (where x=B or T)200 1 Over 1 4 Y 1 Al

Square D UAT-H4213x-FLSQD (where x=C or U)200 1 Ov/Un 1 4 Y 1 Al

Square D UAT-H5203x-FLSQD (where x=B or T)200 1 Over 1 5 Y 3,3a Al

Square D UAT-H5213x-FLSQD (where x=C or U)200 1 Ov/Un 1 5 Y 3,3a Al

Square D UAT-H7203x-FLSQD (where x=B or T)200 3 Over 1 7 Y 4 Al

Square D UAT-H7213x-FLSQD (where x=C or U)200 3 Ov/Un 1 7 Y 4 Al

Square D UAT-RS202B-FLSQD200 1 Over 1 4/5 N 1,2 Al

Square D UAT-RS212C-FLSQD200 1 Ov/Un 1 4/5 N 1,2 Al

Square D UAT-RS213A-FLSQD200 1 Under 1 4/5 N 1,2 Al

Square D UAT-RS213C-FLSQD200 1 Ov/Un 1 4/5 N 1,2 Al

Square D UAT-RS223A-FLSQD200 1 Under 1 4/5 N 1,2 Al

Square D UT-4R2352U-FLSQD200 1 Ov/Un 4 4/5 N 1,2

Square D UT-H4203x-FLSQD (where x=B or T)200 1 Over 1 4 Y 1

Square D UT-H4213x-FLSQD (where x=C or U)200 1 Ov/Un 1 4 Y 1

Square D UT-H5203x-FLSQD (where x=B or T)200 1 Over 1 5 Y 3,3a

Square D UT-H5213x-FLSQD (where x=C or U)200 1 Ov/Un 1 5 Y 3,3a

Square D UT-H7203x-FLSQD (where x=B or T)200 3 Over 1 7 Y 4

Square D UT-H7213x-FLSQD (where x=C or U)200 3 Ov/Un 1 7 Y 4

Square D UT-RS202B-FLSQD200 1 Over 1 4/5 N 1,2

Square D UT-RS212C-FLSQD200 1 Ov/Un 1 4/5 N 1,2

Square D UT-RS213A-FLSQD200 1 Under 1 4/5 N 1,2

Square D UT-RS213C-FLSQD200 1 Ov/Un 1 4/5 N 1,2

Square D UT-RS223A-FLSQD200 1 Under 1 4/5 N 1,2

Square D UT-xR2332U-FLSQD (where x=2-3)200 1 Ov/Un 2-3 4/5 N 1,2

Square D UT-xR2392UU-FLSQD (where x=5-6)200 1 Ov/Un 5-6 4/5 N 1,2

Square D EZML11x225 (where x=1-4)225 1 Mtr Ctr 1-4 5 Y 1,2

Square D EZML31x225 (where x=2-4)225 1 Mtr Ctr 2-4 5 Y 3a

Square D EZML33x225 (where x=1-4)225 3 Mtr Ctr 1 7 Y 4

Square D EZMR11x200X (where x=2-4)225 1 Mtr Ctr 2 5 N 1,2

Square D EZMR11x225 (where x=2-5)225 1 Mtr Ctr 2-5 5 N 1,2

Square D EZMR11x225CU (where x=2-5)225 1 Mtr Ctr 2-5 5 N 1,2

Square D EZMR31x225 (where x=2-5)225 1 Mtr Ctr 2-5 5 N 1,2

Square D SU3040D300L (with Red Dot retrofit label)300 1 Under 1 4/5 Y 3

Square D 1008836SQD400 1 Ov/Un 1 4 Y 1

Square D 1008837SQD400 1 Ov/Un 1 4 Y 1 Al

Square D CU12L400L (with Red Dot retrofit label)400 1 Under 1 4/5 Y 3

Page 13 of 14

FPL - Florida Power Light PEF - Progress Energy-Florida TECO - Tampa Electric GULF - Gulf Power

© 2005, Florida Meter Group

Page 14: Florida Meter Approved Meter Equipment Group Enclosure List€¦ · served by the utilities of the Florida Meter Group. Approval is based on the unit's compliance with the FMG specifications,

Manufacturer Catalog NumberAmps Phase Service Pos Term Bypass Config

Approved Metering Equipment Enclosure List

Participants: FPL, GULF, PEF, TECO

Revised

4/6/2012

Square D EZML31y400 (where y=1-2)400 1 Mtr Ctr 1-2 5 Y 3a

Square D EZML33y400 (where y=1-2)400 3 Mtr Ctr 1-2 7 Y 4

Square D QU12L400xL (where x = C or S)400 1 Under 1 4/5 Y 3

Square D QU816D400SL400 1 Under 1 4/5 Y 3

Square D SU3040D400L (with Red Dot retrofit label)400 1 Under 1 4/5 Y 3

Square D UAT-H4300T-FLSQD400 1 Over 1 4 Y 1 Al

Square D UAT-H5300T-FLSQD400 1 Over 1 5 Y 3,3a Al

Square D UAT-H5330U-FLSQD400 1 Ov/Un 1 5 Y 3,3a Al

Square D UAT-H7300T-FLSQD400 3 Over 1 7 Y 4 Al

Square D UAT-H7330U-FLSQD400 3 Ov/Un 1 7 Y 4 Al

Square D UT-H4300T-FLSQD400 1 Over 1 4 Y 1

Square D UT-H5300T-FLSQD400 1 Over 1 5 Y 3,3a

Square D UT-H5330U-FLSQD400 1 Ov/Un 1 5 Y 3,3a

Square D UT-H7300T-FLSQD400 3 Over 1 7 Y 4

Square D UT-H7330U-FLSQD400 3 Ov/Un 1 7 Y 4

Page 14 of 14

FPL - Florida Power Light PEF - Progress Energy-Florida TECO - Tampa Electric GULF - Gulf Power

© 2005, Florida Meter Group