flow characteristics viscosity determined through index matching, (550 ssu, 109 cp, 0.109 pa-s) –...

6
Flow Characteristics • Viscosity determined through index matching, (550 SSU, 109 cP, 0.109 Pa-s) – Much higher than water (1 cP) • Flow tested by Army is from 2- 10 L/min – Using Reynolds number matching, 6- 32 GPM • Pressure loss through system ranges from 20 psi to 50 psi – Calculated using Poiseuille flow

Upload: brett-higgins

Post on 01-Jan-2016

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Flow Characteristics Viscosity determined through index matching, (550 SSU, 109 cP, 0.109 Pa-s) – Much higher than water (1 cP) Flow tested by Army is

Flow Characteristics

• Viscosity determined through index matching, (550 SSU, 109 cP, 0.109 Pa-s)– Much higher than water (1 cP)

• Flow tested by Army is from 2-10 L/min– Using Reynolds number matching, 6-32 GPM

• Pressure loss through system ranges from 20 psi to 50 psi– Calculated using Poiseuille flow

Page 2: Flow Characteristics Viscosity determined through index matching, (550 SSU, 109 cP, 0.109 Pa-s) – Much higher than water (1 cP) Flow tested by Army is

Positive Displacement vs. Centrifugal

Conclusion: PD pumps provided better flow control, regardless of pressure and handle high viscosities.

Graph Credit: pumpschool.com

Page 3: Flow Characteristics Viscosity determined through index matching, (550 SSU, 109 cP, 0.109 Pa-s) – Much higher than water (1 cP) Flow tested by Army is

PD Pump SelectionPump Flow Rates Pressures Comments Cost (3 highest)

Gear pump Acceptable,Up to 30 gpm

Acceptable,Up to 50 psi

Common, can be self-priming

2

Rotary Vane Acceptable Acceptable Not really used in our application, better for thin fluids and high pressure differentials

2

Diaphragm Acceptable Acceptable Create pulsing flow, need air supply, cheaper

1

Lobe Pump Acceptable Acceptable Used in Sanitary applications where fragile solids are used, bi-rotational, may be overly complex

3

Image Credit: Wikipedia; Info Credit: pumpscout.com

Page 4: Flow Characteristics Viscosity determined through index matching, (550 SSU, 109 cP, 0.109 Pa-s) – Much higher than water (1 cP) Flow tested by Army is

3 GPM 35 GPM

6 GPM 33 GPM19 GPM

Siewert, 1.6-16 GPM, $2,079

Siewert, 3.2-32 GPM, $2,319

Siewert, 2.3-23 GPM, $2,189

Emerick, 3.3-33 GPM, $2,754

Page 5: Flow Characteristics Viscosity determined through index matching, (550 SSU, 109 cP, 0.109 Pa-s) – Much higher than water (1 cP) Flow tested by Army is

• Max flow rate: 33 GPM• Min flow rate: 3.3 GPM• Max Pressure: 200 psi• Speed Ratio: N/A• Price: $2,745• Shipping not included• Lead time: 3-4 weeks

• Max flow rate: 32 GPM• Min flow rate: 3.2 GPM• Max Pressure: 100 psi• Speed Ratio: 10:1• Price: $2,319• Shipping included• Installation Assistance• Lead time: 5-6 weeks

Emerick Siewert

Page 6: Flow Characteristics Viscosity determined through index matching, (550 SSU, 109 cP, 0.109 Pa-s) – Much higher than water (1 cP) Flow tested by Army is

Inhalation Pipe Schematic