flow measurement - bar instruments€¦ · pulsar process measurement leading the world in...
TRANSCRIPT
-
www.pulsar-pm.com
Pulsar ProcessMeasurementLeading the world in non-contactinglevel and flow measurement
Pulsar® Process Measurement Ltd.Cardinal BuildingEnigma Commercial CentreSandy's RoadMalvernWorcestershireWR14 1JJEnglandTel: +44 (0) 1684 891 371Fax: +44 (0) 1684 575 985Email: [email protected]
FlowMicroFlow
• Use with a dB3 transducer and sun-shielded temperature sensor or dB3 with twin sun-shield for MCERTs Class 1 measurement
• 4-20mA, 5 relay outputs• Optional Profibus DP or Modbus communication v0 & v1• Optional data logging• Calculation of flow optimisation, 32-point linearisation• AC or DC power supply
FlowCERT LiteMCERTs Class 1 flow measurement
Flow
• Use with Speedy velocity sensor or MicroFlow• 2x 4-20mA, 5 relay outputs• Optional Profibus DP v0 & v1or Modbus communication• Optional data logging• Calculation of flow optimisation, 32-point linearisation• AC or DC power supply• IP65
FlowCERTHigh-accuracyopen channel flowmeasurement
Flow
• Accurate and repeatable• Velocity x area calculation a low cost alternative to PMD • Minimal installation costs, no interruption to service• Maintenance-free• RS485 Modbus output, can be converted in Pulsar Velocity
Interface to mA or relay• Compatible with Pulsar controllers FlowCERT and Ultimate
for velocity x area flow measurement solution
2x MICROFLOW SENSORS WITH FLOWCERT CONTROLLERS AND DBMACH3 TRANSDUCERS
Flow PulseNon-invasive flow measurement
Flow
OPTIONS INCLUDE FIXED INSTALLATION WALLMOUNTED FLOW MONITOR AND FLOW PULSE
HANDHELD FOR PORTABLE FLOW MONITORING
• No moving parts, vibration-proof• Detects foreign objects within the process• Detects flow/no flow of solids• Material route/flow verification• Bearing failure alarm• 24VDC supply and 0-10V output• ATEX EEx ia options• Fits pipes, chutes and feed hoppers
Non-invasive acoustic sensorFlowPulsarGuard 2010 Series
Vibrating Probes200 Series• No moving parts• Strong, stainless steel build • Tip sensitive - immune to wall
cling• Sharp blade prevents material
build-up• No calibration required• High temp. version 150ºC• Rigid tube and cable
extensions available• EEx ia versions available
Rotating Paddles300 Series• Robust, high reliability switching• High, demand and low level• Low-cost polypropylene
versions• High strength stainless steel• Cable and rigid extension
options• High temp +350ºC option• ATEX dust EEx ia Zone 20/21
option
PressureTransducers700 Series• High stability• ATEX EEx ia options available• Choice of pressure connections• Submersible, low range and
general purpose versions
Float Switches800 Series• High quality & reliability, low cost• Up to 13A current switching• Adjustable pumping range• High quality cable entry seal• Pump up, pump down or SPDT• Resistance to turbulence• Choice of mounting straps and
cable weights• 3m or 10m leads as standard
(longer on request)• SPDT version offers Hi or Lo alarm
Completing the range: When you don’t need complex solutions, just reliability and qualityOther Level Devices Level
• Simple installation – simply fix the unit to the outside of a pipe. IP68.
• DC supply• Version 1 (30-350mm), Version 2 (30-1250mm)• Flow range of 0.3m/s to 4m/s.
10m/s high flow version available• Outputs: RS485 and 4-20mA and 1 relay• Repeatability of approximately ±5%• Fully potted and fast response versions
FLOWCERT LITE + DB3 + INTERNAL TEMPERATURECOMPENSATION WITH TWIN SUN-SHIELDSMCERTS CLASS 1, 0.193% ACCURACYSIRA MC090155/00
Non-contacting Microwave LiquidVelocity Sensor
SPEEDY VELOCITY SENSOR
MICROFLOW WITH (TOP)ULTIMATE CONTROLLER AND(BOTTOM) FLOWCERT FORVELOCITY X AREACALCULATIONS
Pulsar® is a registered trademark of Pulsar ProcessMeasurement Ltd. in the UK, USA and China.
Literature number: 6ppENG/MHA/10-16
-
Volume
VolumeIMPIMP : self containedmeasurementwithout compromise
• Calibrate without compromising the IP67 rating• Mounts on 1.5” universal thread (2” on IMP 10)• Easy to calibrate settings menu on display• Narrow beam angles• 3m, 6m and 10m range versions• 4-20mA loop powered• 2 relays (DC mode)• ‘Lite’ version with 4-20mA output only• Low power consumption and fast response• Intrinsically Safe (I.S.) version available
dBi TransducersdBi Series of Intelligent Level Transducers
Level
Level
From 0mm to50m. High powerand narrowbeam angles
Versatilemultifunctionalcontrollers
• Multiple configurations: level, volume, pump control, open channel flow
• Compatible with the full range of transducers, dB3 (3m) to dB50 (50m)
• Mounting: panel, fascia, wall or rack versions• Choice of output: 3 or 5 relays, 4-20mA• Optional Modbus or Profibus DP v0 and v1 communication• Optional data logging• Calculation of flow optimisation, 32-point linearisation• Sophisticated tank functions for volume calculations• AC or DC power supply• IP65 wall mount, IP64 fascia, IP54 panel
Ultra 3 & 5Ultra Twin
BlackboxUltrasonic systemwith range ofoutputs
Level Volume
ULTRA 3 RACK MOUNT
ULTRA 5 WETWELL CONTROL
• For use with Blackbox, Ultra, Zenith, Quantum and Ultimate • Special dBMACH3 (0mm deadband) transducer for open
channel flow• IP68• 1000m maximum between transducer and controller• PVDF, PTFE chemical resistant faces and solid application
(aiming kit) options• ATEX Zone 1 standard. FM option available• Optional Intrinsically Safe (I.S.) ATEX Zone 0
Level Sludge Blanket
• Self-cleaning transducer• Simple installation and reduced maintenance• Suitable for all types of sludge (primary,
secondary, tertiary and industrial)• 0.5% density threshold minimum• Flexible, immersible mounting rod • Relay output, 2 x 4-20mA outputs• Viewable profile of sludge blanket• Dual Channel unit
Ultrasonic sludgeinterface controller
Sludge Finder 2
Level FlowVolume Pump Control
• Programmable via PC or handheld programmer• Compatible with the full range of transducers,
dB3 (3m) to dB40 (40m)• Outputs (depending on model):
• 2 relays and 4-20mA• 2 relays and 0-5V• 2 relay output and Modbus or Profibus
• Low power data logging version• Optional volume calculations display• AC or DC power supply• IP66 with keypad, IP67 without keypad
• Advanced pump control functions• Compatible with dB series transducers, dBMACH3 (0m)
to dB40 (40m)• 8 digital inputs, 8 digital outputs and 2 mA outputs built
in, expandable with interface modules• Dedicated web server remote control• Optional infra red camera• Logical, colour touch-screen setup• Optional battery backup• Extensive data logging for Asset Management, Predictive
Maintenance and Compliance• Pump Performance Indicator, API Asset Performance
Index and pre-blockage detection plus optional pump reversing
• Interface with flow monitors such as Flow Pulse • RTU with Wi-Fi and GPRS/3G options. DNP3 (WITS 1.1)• IP64 fascia, IP65 wall
Ultimate Controller
Complete pump process control. Ultrasoniclevel, flow control and RTU
Zenith &Quantum
Intelligent controlsystems forpumping stationcontrol
Pump Control
ZENITH, QUANTUM ANDULTIMATE CONTROLLERAPPLICATIONS
Level FlowVolume Pump Control
• Advanced pump control functions• Compatible with dB series transducers,
dB3 (3m) to dB40 (40m)• Optional 6 or 10 relay outputs, 7 digital
inputs, 4-20mA output• Optional Modbus or Profibus DP v0 or v1
communication• Optional data logging• AC or DC power supply• IP64
• DATEM ( digital echo processing )• Non-contacting level and volume measurement• IP68• 2 models HART protocol (version 7) or Profibus PA (3.0.2)• Low power consumption• Solids or liquids applications, available in 4 versions
125mm to 15m for each protocol• ATEX Ex mb Zone 1 standard• Option of ATEX Zone 0 I.S.
dB Transducers for use with Pulsar Controllers (2 part system)
Pulsar Process Measurement Limited operates a policy of constant developmentand improvement and reserves the right to amend technical details as necessary
-
Volume
VolumeIMPIMP : self containedmeasurementwithout compromise
• Calibrate without compromising the IP67 rating• Mounts on 1.5” universal thread (2” on IMP 10)• Easy to calibrate settings menu on display• Narrow beam angles• 3m, 6m and 10m range versions• 4-20mA loop powered• 2 relays (DC mode)• ‘Lite’ version with 4-20mA output only• Low power consumption and fast response• Intrinsically Safe (I.S.) version available
dBi TransducersdBi Series of Intelligent Level Transducers
Level
Level
From 0mm to50m. High powerand narrowbeam angles
Versatilemultifunctionalcontrollers
• Multiple configurations: level, volume, pump control, open channel flow
• Compatible with the full range of transducers, dB3 (3m) to dB50 (50m)
• Mounting: panel, fascia, wall or rack versions• Choice of output: 3 or 5 relays, 4-20mA• Optional Modbus or Profibus DP v0 and v1 communication• Optional data logging• Calculation of flow optimisation, 32-point linearisation• Sophisticated tank functions for volume calculations• AC or DC power supply• IP65 wall mount, IP64 fascia, IP54 panel
Ultra 3 & 5Ultra Twin
BlackboxUltrasonic systemwith range ofoutputs
Level Volume
ULTRA 3 RACK MOUNT
ULTRA 5 WETWELL CONTROL
• For use with Blackbox, Ultra, Zenith, Quantum and Ultimate • Special dBMACH3 (0mm deadband) transducer for open
channel flow• IP68• 1000m maximum between transducer and controller• PVDF, PTFE chemical resistant faces and solid application
(aiming kit) options• ATEX Zone 1 standard. FM option available• Optional Intrinsically Safe (I.S.) ATEX Zone 0
Level Sludge Blanket
• Self-cleaning transducer• Simple installation and reduced maintenance• Suitable for all types of sludge (primary,
secondary, tertiary and industrial)• 0.5% density threshold minimum• Flexible, immersible mounting rod • Relay output, 2 x 4-20mA outputs• Viewable profile of sludge blanket• Dual Channel unit
Ultrasonic sludgeinterface controller
Sludge Finder 2
Level FlowVolume Pump Control
• Programmable via PC or handheld programmer• Compatible with the full range of transducers,
dB3 (3m) to dB40 (40m)• Outputs (depending on model):
• 2 relays and 4-20mA• 2 relays and 0-5V• 2 relay output and Modbus or Profibus
• Low power data logging version• Optional volume calculations display• AC or DC power supply• IP66 with keypad, IP67 without keypad
• Advanced pump control functions• Compatible with dB series transducers, dBMACH3 (0m)
to dB40 (40m)• 8 digital inputs, 8 digital outputs and 2 mA outputs built
in, expandable with interface modules• Dedicated web server remote control• Optional infra red camera• Logical, colour touch-screen setup• Optional battery backup• Extensive data logging for Asset Management, Predictive
Maintenance and Compliance• Pump Performance Indicator, API Asset Performance
Index and pre-blockage detection plus optional pump reversing
• Interface with flow monitors such as Flow Pulse • RTU with Wi-Fi and GPRS/3G options. DNP3 (WITS 1.1)• IP64 fascia, IP65 wall
Ultimate Controller
Complete pump process control. Ultrasoniclevel, flow control and RTU
Zenith &Quantum
Intelligent controlsystems forpumping stationcontrol
Pump Control
ZENITH, QUANTUM ANDULTIMATE CONTROLLERAPPLICATIONS
Level FlowVolume Pump Control
• Advanced pump control functions• Compatible with dB series transducers,
dB3 (3m) to dB40 (40m)• Optional 6 or 10 relay outputs, 7 digital
inputs, 4-20mA output• Optional Modbus or Profibus DP v0 or v1
communication• Optional data logging• AC or DC power supply• IP64
• DATEM ( digital echo processing )• Non-contacting level and volume measurement• IP68• 2 models HART protocol (version 7) or Profibus PA (3.0.2)• Low power consumption• Solids or liquids applications, available in 4 versions
125mm to 15m for each protocol• ATEX Ex mb Zone 1 standard• Option of ATEX Zone 0 I.S.
dB Transducers for use with Pulsar Controllers (2 part system)
Pulsar Process Measurement Limited operates a policy of constant developmentand improvement and reserves the right to amend technical details as necessary
-
Volume
VolumeIMPIMP : self containedmeasurementwithout compromise
• Calibrate without compromising the IP67 rating• Mounts on 1.5” universal thread (2” on IMP 10)• Easy to calibrate settings menu on display• Narrow beam angles• 3m, 6m and 10m range versions• 4-20mA loop powered• 2 relays (DC mode)• ‘Lite’ version with 4-20mA output only• Low power consumption and fast response• Intrinsically Safe (I.S.) version available
dBi TransducersdBi Series of Intelligent Level Transducers
Level
Level
From 0mm to50m. High powerand narrowbeam angles
Versatilemultifunctionalcontrollers
• Multiple configurations: level, volume, pump control, open channel flow
• Compatible with the full range of transducers, dB3 (3m) to dB50 (50m)
• Mounting: panel, fascia, wall or rack versions• Choice of output: 3 or 5 relays, 4-20mA• Optional Modbus or Profibus DP v0 and v1 communication• Optional data logging• Calculation of flow optimisation, 32-point linearisation• Sophisticated tank functions for volume calculations• AC or DC power supply• IP65 wall mount, IP64 fascia, IP54 panel
Ultra 3 & 5Ultra Twin
BlackboxUltrasonic systemwith range ofoutputs
Level Volume
ULTRA 3 RACK MOUNT
ULTRA 5 WETWELL CONTROL
• For use with Blackbox, Ultra, Zenith, Quantum and Ultimate • Special dBMACH3 (0mm deadband) transducer for open
channel flow• IP68• 1000m maximum between transducer and controller• PVDF, PTFE chemical resistant faces and solid application
(aiming kit) options• ATEX Zone 1 standard. FM option available• Optional Intrinsically Safe (I.S.) ATEX Zone 0
Level Sludge Blanket
• Self-cleaning transducer• Simple installation and reduced maintenance• Suitable for all types of sludge (primary,
secondary, tertiary and industrial)• 0.5% density threshold minimum• Flexible, immersible mounting rod • Relay output, 2 x 4-20mA outputs• Viewable profile of sludge blanket• Dual Channel unit
Ultrasonic sludgeinterface controller
Sludge Finder 2
Level FlowVolume Pump Control
• Programmable via PC or handheld programmer• Compatible with the full range of transducers,
dB3 (3m) to dB40 (40m)• Outputs (depending on model):
• 2 relays and 4-20mA• 2 relays and 0-5V• 2 relay output and Modbus or Profibus
• Low power data logging version• Optional volume calculations display• AC or DC power supply• IP66 with keypad, IP67 without keypad
• Advanced pump control functions• Compatible with dB series transducers, dBMACH3 (0m)
to dB40 (40m)• 8 digital inputs, 8 digital outputs and 2 mA outputs built
in, expandable with interface modules• Dedicated web server remote control• Optional infra red camera• Logical, colour touch-screen setup• Optional battery backup• Extensive data logging for Asset Management, Predictive
Maintenance and Compliance• Pump Performance Indicator, API Asset Performance
Index and pre-blockage detection plus optional pump reversing
• Interface with flow monitors such as Flow Pulse • RTU with Wi-Fi and GPRS/3G options. DNP3 (WITS 1.1)• IP64 fascia, IP65 wall
Ultimate Controller
Complete pump process control. Ultrasoniclevel, flow control and RTU
Zenith &Quantum
Intelligent controlsystems forpumping stationcontrol
Pump Control
ZENITH, QUANTUM ANDULTIMATE CONTROLLERAPPLICATIONS
Level FlowVolume Pump Control
• Advanced pump control functions• Compatible with dB series transducers,
dB3 (3m) to dB40 (40m)• Optional 6 or 10 relay outputs, 7 digital
inputs, 4-20mA output• Optional Modbus or Profibus DP v0 or v1
communication• Optional data logging• AC or DC power supply• IP64
• DATEM ( digital echo processing )• Non-contacting level and volume measurement• IP68• 2 models HART protocol (version 7) or Profibus PA (3.0.2)• Low power consumption• Solids or liquids applications, available in 4 versions
125mm to 15m for each protocol• ATEX Ex mb Zone 1 standard• Option of ATEX Zone 0 I.S.
dB Transducers for use with Pulsar Controllers (2 part system)
Pulsar Process Measurement Limited operates a policy of constant developmentand improvement and reserves the right to amend technical details as necessary
-
www.pulsar-pm.com
Pulsar ProcessMeasurementLeading the world in non-contactinglevel and flow measurement
Pulsar® Process Measurement Ltd.Cardinal BuildingEnigma Commercial CentreSandy's RoadMalvernWorcestershireWR14 1JJEnglandTel: +44 (0) 1684 891 371Fax: +44 (0) 1684 575 985Email: [email protected]
FlowMicroFlow
• Use with a dB3 transducer and sun-shielded temperature sensor or dB3 with twin sun-shield for MCERTs Class 1 measurement
• 4-20mA, 5 relay outputs• Optional Profibus DP or Modbus communication v0 & v1• Optional data logging• Calculation of flow optimisation, 32-point linearisation• AC or DC power supply
FlowCERT LiteMCERTs Class 1 flow measurement
Flow
• Use with Speedy velocity sensor or MicroFlow• 2x 4-20mA, 5 relay outputs• Optional Profibus DP v0 & v1or Modbus communication• Optional data logging• Calculation of flow optimisation, 32-point linearisation• AC or DC power supply• IP65
FlowCERTHigh-accuracyopen channel flowmeasurement
Flow
• Accurate and repeatable• Velocity x area calculation a low cost alternative to PMD • Minimal installation costs, no interruption to service• Maintenance-free• RS485 Modbus output, can be converted in Pulsar Velocity
Interface to mA or relay• Compatible with Pulsar controllers FlowCERT and Ultimate
for velocity x area flow measurement solution
2x MICROFLOW SENSORS WITH FLOWCERT CONTROLLERS AND DBMACH3 TRANSDUCERS
Flow PulseNon-invasive flow measurement
Flow
OPTIONS INCLUDE FIXED INSTALLATION WALLMOUNTED FLOW MONITOR AND FLOW PULSE
HANDHELD FOR PORTABLE FLOW MONITORING
• No moving parts, vibration-proof• Detects foreign objects within the process• Detects flow/no flow of solids• Material route/flow verification• Bearing failure alarm• 24VDC supply and 0-10V output• ATEX EEx ia options• Fits pipes, chutes and feed hoppers
Non-invasive acoustic sensorFlowPulsarGuard 2010 Series
Vibrating Probes200 Series• No moving parts• Strong, stainless steel build • Tip sensitive - immune to wall
cling• Sharp blade prevents material
build-up• No calibration required• High temp. version 150ºC• Rigid tube and cable
extensions available• EEx ia versions available
Rotating Paddles300 Series• Robust, high reliability switching• High, demand and low level• Low-cost polypropylene
versions• High strength stainless steel• Cable and rigid extension
options• High temp +350ºC option• ATEX dust EEx ia Zone 20/21
option
PressureTransducers700 Series• High stability• ATEX EEx ia options available• Choice of pressure connections• Submersible, low range and
general purpose versions
Float Switches800 Series• High quality & reliability, low cost• Up to 13A current switching• Adjustable pumping range• High quality cable entry seal• Pump up, pump down or SPDT• Resistance to turbulence• Choice of mounting straps and
cable weights• 3m or 10m leads as standard
(longer on request)• SPDT version offers Hi or Lo alarm
Completing the range: When you don’t need complex solutions, just reliability and qualityOther Level Devices Level
• Simple installation – simply fix the unit to the outside of a pipe. IP68.
• DC supply• Version 1 (30-350mm), Version 2 (30-1250mm)• Flow range of 0.3m/s to 4m/s.
10m/s high flow version available• Outputs: RS485 and 4-20mA and 1 relay• Repeatability of approximately ±5%• Fully potted and fast response versions
FLOWCERT LITE + DB3 + INTERNAL TEMPERATURECOMPENSATION WITH TWIN SUN-SHIELDSMCERTS CLASS 1, 0.193% ACCURACYSIRA MC090155/00
Non-contacting Microwave LiquidVelocity Sensor
SPEEDY VELOCITY SENSOR
MICROFLOW WITH (TOP)ULTIMATE CONTROLLER AND(BOTTOM) FLOWCERT FORVELOCITY X AREACALCULATIONS
Pulsar® is a registered trademark of Pulsar ProcessMeasurement Ltd. in the UK, USA and China.
Literature number: 6ppENG/MHA/10-16
-
www.pulsar-pm.com
Pulsar ProcessMeasurementLeading the world in non-contactinglevel and flow measurement
Pulsar® Process Measurement Ltd.Cardinal BuildingEnigma Commercial CentreSandy's RoadMalvernWorcestershireWR14 1JJEnglandTel: +44 (0) 1684 891 371Fax: +44 (0) 1684 575 985Email: [email protected]
FlowMicroFlow
• Use with a dB3 transducer and sun-shielded temperature sensor or dB3 with twin sun-shield for MCERTs Class 1 measurement
• 4-20mA, 5 relay outputs• Optional Profibus DP or Modbus communication v0 & v1• Optional data logging• Calculation of flow optimisation, 32-point linearisation• AC or DC power supply
FlowCERT LiteMCERTs Class 1 flow measurement
Flow
• Use with Speedy velocity sensor or MicroFlow• 2x 4-20mA, 5 relay outputs• Optional Profibus DP v0 & v1or Modbus communication• Optional data logging• Calculation of flow optimisation, 32-point linearisation• AC or DC power supply• IP65
FlowCERTHigh-accuracyopen channel flowmeasurement
Flow
• Accurate and repeatable• Velocity x area calculation a low cost alternative to PMD • Minimal installation costs, no interruption to service• Maintenance-free• RS485 Modbus output, can be converted in Pulsar Velocity
Interface to mA or relay• Compatible with Pulsar controllers FlowCERT and Ultimate
for velocity x area flow measurement solution
2x MICROFLOW SENSORS WITH FLOWCERT CONTROLLERS AND DBMACH3 TRANSDUCERS
Flow PulseNon-invasive flow measurement
Flow
OPTIONS INCLUDE FIXED INSTALLATION WALLMOUNTED FLOW MONITOR AND FLOW PULSE
HANDHELD FOR PORTABLE FLOW MONITORING
• No moving parts, vibration-proof• Detects foreign objects within the process• Detects flow/no flow of solids• Material route/flow verification• Bearing failure alarm• 24VDC supply and 0-10V output• ATEX EEx ia options• Fits pipes, chutes and feed hoppers
Non-invasive acoustic sensorFlowPulsarGuard 2010 Series
Vibrating Probes200 Series• No moving parts• Strong, stainless steel build • Tip sensitive - immune to wall
cling• Sharp blade prevents material
build-up• No calibration required• High temp. version 150ºC• Rigid tube and cable
extensions available• EEx ia versions available
Rotating Paddles300 Series• Robust, high reliability switching• High, demand and low level• Low-cost polypropylene
versions• High strength stainless steel• Cable and rigid extension
options• High temp +350ºC option• ATEX dust EEx ia Zone 20/21
option
PressureTransducers700 Series• High stability• ATEX EEx ia options available• Choice of pressure connections• Submersible, low range and
general purpose versions
Float Switches800 Series• High quality & reliability, low cost• Up to 13A current switching• Adjustable pumping range• High quality cable entry seal• Pump up, pump down or SPDT• Resistance to turbulence• Choice of mounting straps and
cable weights• 3m or 10m leads as standard
(longer on request)• SPDT version offers Hi or Lo alarm
Completing the range: When you don’t need complex solutions, just reliability and qualityOther Level Devices Level
• Simple installation – simply fix the unit to the outside of a pipe. IP68.
• DC supply• Version 1 (30-350mm), Version 2 (30-1250mm)• Flow range of 0.3m/s to 4m/s.
10m/s high flow version available• Outputs: RS485 and 4-20mA and 1 relay• Repeatability of approximately ±5%• Fully potted and fast response versions
FLOWCERT LITE + DB3 + INTERNAL TEMPERATURECOMPENSATION WITH TWIN SUN-SHIELDSMCERTS CLASS 1, 0.193% ACCURACYSIRA MC090155/00
Non-contacting Microwave LiquidVelocity Sensor
SPEEDY VELOCITY SENSOR
MICROFLOW WITH (TOP)ULTIMATE CONTROLLER AND(BOTTOM) FLOWCERT FORVELOCITY X AREACALCULATIONS
Pulsar® is a registered trademark of Pulsar ProcessMeasurement Ltd. in the UK, USA and China.
Literature number: 6ppENG/MHA/10-16