PEAK PLAYBACK: Reads the highest value displayed on the Gauge since the last time the PEAK value was dis- played. PEAK value will be held in memory until erased by pressing the RIGHT or LEFT button while in the PEAK level Press the center button to advance to HIGH RED-LINE SETTING. LOW THRESHOLD SETTING: Press the center button to advance to COLOR SCHEME. PEAK LIGHT LIT PEAK LOW HI PRESS LOW LIGHT LIT PEAK LOW HI PRESS PEAK,LOW,HI LIGHT LIT PEAK LOW HI PRESS PEAK,LOW,HI LIGHT LIT PEAK LOW HI PRESS ONE AT A TIME DOWN - UP + LOW LIGHT LIT PEAK LOW HI PRESS ONE AT A TIME DOWN - UP + PEAK LIGHT LIT PEAK LOW HI PRESS Flow Chart Programming Instructions for : Air/Fuel Ratio Gauge 2 1/16ProParts, LLC • PO Box 360 • Annapolis Junction MD • 20701 www.ProPartsLLc.com • [email protected] • ph: 301 490 7700 • fax: 301 490 3700 A PROGRAM MAIN MENU START HERE MAIN MENU (Press one button at a time) NORMAL/DIAL BRIGHTNESS: Press the down or up button to adjust dial brightness. Press the center button to save and advance to PEAK PLAYBACK. NORMAL LIGHTING PEAK LOW HI PRESS ONE AT A TIME DOWN - UP + HIGH RED-LINE SETTING: Press the down or up button to move dial pointer to the high threshold. Press the center button to save and advance to LOW THRESHOLD SETTING. HI LIGHT LIT PEAK LOW HI PRESS ONE AT A TIME DOWN - UP + LOW THRESHOLD SETTING: Press the down or up button to move pointer to low threshold. Press the center button to save and advance to COLOR SCHEME. COLOR SCHEME: Press down and up buttons to select a color scheme. (OFF-VIOLET-BLUE-GREEN-YELLOW- ORANGE-RED-WHITE). Press the center button to save and return to NORMAL/DIAL BRIGHTNESS. NORMAL/DIAL BRIGHTNESS: ON POWER UP THE GAUGE READS THE RATIO. Press the center button to advance to PEAK PLAYBACK. OPTION: SET NARROW vs WIDE BAND OXYGEN SENSOR NORMAL LIGHTING PEAK LOW HI PRESS PEAK PLAYBACK: Press the center button to advance to HIGH RED-LINE SETTING. OR OPTION:RESTORE FACTORY DEFAULT HIGH RED-LINE SETTING: Press the center button to advance to LOW THRESHOLD SETTING. HI LIGHT LIT PEAK LOW HI PRESS COLOR SCHEME: Press the center button to advance to NORMAL/DIAL BRIGHTNESS. OR OPTION :DEMO MODE Down Button PEAK LOW HI Up Button Mode Button Patents # 7,612,6600, 7,278,749 Additional Patents Pending PEAK,LOW,HI LIGHT LIT PEAK LOW HI PRESS ONE AT A TIME DOWN - UP + DIAL BRIGHTNESS: Press the RIGHT or LEFT command buttons to Control the brightness of the faceplate illumina- tion. Press the center button to save and ad- vance to NORMAL OPERATION. PEAK,LOW,HI LIGHT LIT PEAK LOW HI PRESS DIAL BRIGHTNESS: Press the center button to advance to NORMAL OPERATION OPTION A:POINTER BRIGHTNESS

Upload: others

Post on 29-Nov-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FlowChartProgrammingInstructionsfor:Air/FuelRatioGauge 2 1 ...€¦ · PRESS BOTH ProParts,LLC • POBox360• AnnapolisJunction MD • 20701 B • sales@ProPartsLLc.com • ph:3014907700

PEAK PLAYBACK:Reads the highest value displayed on the Gaugesince the last time the PEAK value was dis-played. PEAK value will be held in memory untilerased by pressing the RIGHT or LEFT buttonwhile in the PEAK level Press the center buttonto advance to HIGH RED-LINE SETTING.

LOW THRESHOLD SETTING:Press the center button to advance toCOLOR SCHEME.

PEAKLIGHT LIT

PEAK LOW HI

PRESS

LOWLIGHT LIT

PEAK LOW HI

PRESS

PEAK,LOW,HILIGHT LIT

PEAK LOW HI

PRESS

PEAK,LOW,HILIGHT LIT

PEAK LOW HI

PRESS ONEAT A TIME

DOWN-

UP+

LOWLIGHT LIT

PEAK LOW HI

PRESS ONEAT A TIME

DOWN-

UP+

PEAKLIGHT LIT

PEAK LOW HI

PRESS

Flow Chart Programming Instructions for : Air/Fuel Ratio Gauge 2 1/16”

ProParts, LLC • PO Box 360 • Annapolis Junction MD • 20701www.ProPartsLLc.com • [email protected] • ph: 301 490 7700 • fax: 301 490 3700 A

PROGRAM MAIN MENU

START HEREMAIN MENU

(Press onebutton at a time)

NORMAL/DIAL BRIGHTNESS:Press the down or up button to adjust dialbrightness. Press the center button to save andadvance to PEAK PLAYBACK.

NORMALLIGHTING

PEAK LOW HI

PRESS ONEAT A TIME

DOWN-

UP+

HIGH RED-LINE SETTING:Press the down or up button to move dialpointer to the high threshold. Press the centerbutton to save and advance to LOWTHRESHOLD SETTING.

HILIGHT LIT

PEAK LOW HI

PRESS ONEAT A TIME

DOWN-

UP+

LOW THRESHOLD SETTING:Press the down or up button to move pointer tolow threshold. Press the center button to saveand advance to COLOR SCHEME.

COLOR SCHEME:Press down and up buttons to select a colorscheme. (OFF-VIOLET-BLUE-GREEN-YELLOW-ORANGE-RED-WHITE). Press the center buttonto save and return to NORMAL/DIALBRIGHTNESS.

NORMAL/DIAL BRIGHTNESS:ON POWER UP THE GAUGE READS THERATIO. Press the center button toadvance to PEAK PLAYBACK.OPTION: SET NARROW vs WIDE BANDOXYGEN SENSOR

NORMALLIGHTING

PEAK LOW HI

PRESS

PEAK PLAYBACK:Press the center button to advance to HIGHRED-LINE SETTING. OROPTION:RESTORE FACTORY DEFAULT

HIGH RED-LINE SETTING:Press the center button to advance toLOW THRESHOLD SETTING.

HILIGHT LIT

PEAK LOW HI

PRESS

COLOR SCHEME:Press the center button to advance toNORMAL/DIAL BRIGHTNESS. OROPTION :DEMO MODE

DownButton

PEAK

LOWHI

UpButton

ModeButton

Patents # 7,612,6600, 7,278,749Additional Patents Pending

PEAK,LOW,HILIGHT LIT

PEAK LOW HI

PRESS ONEAT A TIME

DOWN-

UP+

DIAL BRIGHTNESS:Press the RIGHT or LEFT command buttons toControl the brightness of the faceplate illumina-tion. Press the center button to save and ad-vance to NORMAL OPERATION. PEAK,LOW,HI

LIGHT LIT

PEAK LOW HI

PRESS DIAL BRIGHTNESS:Press the center button toadvance to NORMAL OPERATIONOPTION A:POINTER BRIGHTNESS

Page 2: FlowChartProgrammingInstructionsfor:Air/FuelRatioGauge 2 1 ...€¦ · PRESS BOTH ProParts,LLC • POBox360• AnnapolisJunction MD • 20701 B • sales@ProPartsLLc.com • ph:3014907700

PRESSBOTH

ProParts, LLC • PO Box 360 • Annapolis Junction MD • 20701www.ProPartsLLc.com • [email protected] • ph: 301 490 7700 • fax: 301 490 3700B

ProParts, LLC Limited Warranty: ProParts, LLC warrants all merchandise against de-fects in factory workmanship and material for 12 months from the originalpurchase date. Proof of purchase is required; otherwise the warranty period shalldefault to 12 months from date of manufacture as indicated by the date code onthe product. This warranty applies to the first retail purchaser and covers onlythose products exposed to normal use or service. This warranty excludes itemsused for purpose to which it is not designed, or which has been altered in any waythat would be detrimental to the performance or life of the product bymisapplication, misuse, negligence or accident. When it is determined by ProParts,LLC after examination that a product is defective, ProParts, LLC will repair, replace

or issue credit for that product through the original selling dealer or by direct basis.In no event shall this warranty exceed the original price of the product. ProParts,LLC assumes no responsibility for diagnosis, removal and/or installation labor, lossof vehicles use, loss of time, inconvenience or any other consequential expense.ProParts, LLC disclaims any liability for consequential damage due to breach of anywritten or implied warranty on all products manufactured by ProParts,LLC.The purchaser or user of any products distributed, sold or manufactured byProParts, LLC assumes all risk related to and/or arising from the ownership or useof said product and agrees to indemnify and hold ProParts,LLC harmless from anyand all claims brought by any person or entity against ProParts, LLC related to

and/or arising from ownership and/or use of said product.Return goods authorization: Warranty returns will only be accepted by ProParts,LLC when accompanied by a valid return good authorization ( RGA) number.Product must be received by ProParts, LLC within 30 days of the date the rga is is-sued. Before a rga can be issued, the installer or end user must contact ProParts,LLC’s technical department to discuss the problem.Any out of warranty ProParts, LLC products can be returned for repair. There is aminimum charge of $50.00 for inspection and diagnosis. ProParts, LLC will providean estimate of repairs and receive written authorization before repairs are made tothe product.

Flow Chart Programming Instructions for : Air/Fuel Ratio Gauge 2 1/16”

SUBMENU(ENTER FROM MAIN MENU)

(Press two(2) buttons simultaneously for 5 seconds)

OPTION:RESTORE FACTORY DEFAULT:While in PEAK PLAYBACK, press and hold thecenter and right buttons for five seconds. Dialpointer will step five times and return to zero.This will erase all user-programmed calibrationsand settings, and return to NORMAL/DIALBRIGHTNESS.

OPTION A:DEMO MODE:WHILE IN COLOR SCHEME, press and hold the center andright buttons for five seconds. Dial will scroll through theseven color schemes. The HI,LOW and PEAK will light,and the dial pointer will move. Press the center button toreturn to NORMAL/DIAL BRIGHTNESS.

OPTION B:POINTER BRIGHTNESS:While in DIAL BRIGHTNESS, press and hold the centerand left buttons for five seconds to enter pointerbrightness mode. The dial pointer will start to flash andpoint to the upper right.

OPTION B:POINTER BRIGHTNESS:Press down and up buttons toadjust the pointer brightness. Press thecenter button to save and return toNORMAL/DIAL BRIGHTNESS.

PRESS

PRESS ONEAT A TIME

DOWN-

UP+

PRESSBOTH

OPTION: SET WIDE vs NARROWBAND SENSORThe default sensor setting for the gauge is narrowband.If a wideband sensor is required, install the following program.While in NORMAL OPERATION press and hold the center andright buttons for five seconds. The pointer will step five timesand the dial faceplate will flash BLUE rapidly.

To specify the wideband sensor press the right (UP)button, the meter pointer will swing to the 3 oʼclockposition. To specify the narrowband sensor press the left(DOWN) button. The pointer will swing to the 9:00 position.Then press the center MODE button to save the settingand return to NORMAL OPERATION

PRESSBOTH

U.S. Patent #7,278,749U.S. Patent #7,612,660Additional Patents PendingAll Rights Reservd

Page 3: FlowChartProgrammingInstructionsfor:Air/FuelRatioGauge 2 1 ...€¦ · PRESS BOTH ProParts,LLC • POBox360• AnnapolisJunction MD • 20701 B • sales@ProPartsLLc.com • ph:3014907700

Programming Instructions for : Air/Fuel Ratio2 1/16” Monitor & Controller

ProParts, LLC • PO Box 360 • Annapolis Junction MD • 20701www.ProPartsLLc.com • [email protected] • ph: 301 490 7700 • fax: 301 490 3700

SPEK PRO™ MONITOR AND CONTROL

Refer to the “Flow Chart Programming Instructions” while reviewing this guide.Gauge is field programmable by the operator while installed in the vehicle. This programming is ac-cessed by pressing the control buttons located on the face or the meter dial, ONE AT A TIME. The“Down” and “Up” buttons move the pointer to a desired setting or controls the faceplate illumination.

1

NORMAL/DIAL BRIGHTNESS

PEAK PLAYBACK

HIGH RED-LINE SETTING

LOW THRESHOLD SETTING

COLOR SCHEME

DIAL BRIGHTNESS

PROGRAM AIR/FUEL SENSOR

OPTION:RESTORE FACTORY DEFAULT

OPTION :DEMO MODE

OPTION: DIAL POINTER BRIGHTNESS

MAIN MENU SUBMENUPRESS “MODE” BUTTON TO PROGRAM LEVEL. THEN PRESS BOTH CENTER ANDLEFT OR CENTER AND RIGHT BUTTONS FOR FIVE SECONDS TO ENTER SUBMENU

DOWN MODE UP+–

Patent Pending

Page 4: FlowChartProgrammingInstructionsfor:Air/FuelRatioGauge 2 1 ...€¦ · PRESS BOTH ProParts,LLC • POBox360• AnnapolisJunction MD • 20701 B • sales@ProPartsLLc.com • ph:3014907700

PROGRAMMING STARTS IN

MAIN MENUPRESS PROGRAM BUTTON ONE (1) AT A TIME IN THE MAIN MENU MODE.

1 NORMAL/DIAL BRIGHTNESS:On power up, the meter usually starts operation in NORMAL/DIAL BRIGHTNESS. Gauge reads thesensor value as temperature, pressure, etc. The “Down” and “Up” buttons will control thebrightness of the dial lighting. Press the center “Mode” button to save the setting and advance you toPEAK PLAYBACK

2 PEAK PLAYBACK:Reads the highest value displayed on the gauge since the last time the “PEAK” value was displayed.PEAK value will be held in memory until erased by pressing the RIGHT or LEFT button in the PEAKlevel. Press the center “Mode” button to advance to HIGH RED-LINE SETTING

3 HIGH RED-LINE SETTING:Sets the point at which “HIGH” warning threshold is reached for that specific gauge. The “Down and“Up” buttons will move the dial pointer to select HIGH RED-LINE SETTING. During normaloperation the gauge constantly monitors the sensor value and compares it to the “HIGH” threshold.If the threshold is exceeded, the dial will flash RED. Press the center “Mode” button to save the set-ting and advance to LOW THRESHOLD SETTING

4 LOW THRESHOLD SETTING:Set the Minimum Threshold: Sets the point at which “LOW” warning threshold is reached for thatspecific gauge. The “Down” and “Up” buttons will move the dial pointer to select the LOWTHRESHOLD SETTING. During normal operation the gauge constantly monitors the sensor valueand compares it to the “LOW” threshold. If the sensor value drops below the threshold, the dial willflash YELLOW. Press the center “Mode” button save the setting and advance to5 COLOR SCHEME

5 COLOR SCHEME:Set Faceplate Color Scheme: Operator can select the color of the gauge dial illumination. Eachtime you press the “Down” control button you scroll through dial color selection until the diallight goes off. Then press the “Up” button to reverse the scroll. Select your dial color illuminationby pressing the center “Mode” button to save the setting and advance to DIAL BRIGHT-NESS

6 DIAL BRIGHTNESS:Adjus dial brightness for day or evening driving conditions. The RIGHT and LEFT command but-tons will dim or brighten the faceplate illumination. Select your dial illumination by pressing thecenter “Mode button to save the setting and advance to NORMAL OPERATION.

Programming Instructions for : Air/Fuel Ratio2 1/16” Monitor & Controller

ProParts, LLC • PO Box 360 • Annapolis Junction, MD • 20701www.ProPartsLLc.com • [email protected] • ph: 301 490 7700 • fax: 301 490 3700 2

Page 5: FlowChartProgrammingInstructionsfor:Air/FuelRatioGauge 2 1 ...€¦ · PRESS BOTH ProParts,LLC • POBox360• AnnapolisJunction MD • 20701 B • sales@ProPartsLLc.com • ph:3014907700

ProParts, LLC • PO Box 360 • Annapolis Junction MD • 20701www.ProPartsLLc.com • [email protected] • ph: 301 490 7700 • fax: 301 490 3700

SUBMENU

SUBMENU IS ACCESSED THROUGH THE MAIN MENU. FIRST GO TO THE APPROPRIATE LEVEL OF THEMAIN MENU AND THEN FOLLOW THE INSTRUCTIONS IN THE PROGRAMMING FLOW DIAGRAM TOENTER THE SUBMENU. PRESS THE “MODE” AND “UP” OR “MODE” AND “DOWN” BUTTONSSIMULTANEOUSLY FOR 5 SECONDS TO ENTER THE SUBMENU AND ONE BUTTON AT A TIME WHILE INTHAT SUBMENU.

SETTING WIDE VERSUS NARROW OXYGEN SENSOR: FROM THE MAIN MENU,NORMAL/DIAL BRIGHTNESS LEVEL PRESS THE CENTER (MODE) AND RIGHT (UP) BUTTONS SIMULTANEOUSLY FORFIVE SECONDS, THE DIAL FACEPLATE WILL RAPIDLY FLASH BLUE. TO SPECIFY THE WIDEBAND SENSOR, PRESSTHE RIGHT (UP) BUTTON. THE METER’S POINTER WILL SWING TO THREE O’CLOCK POSITION. PRESS THE CENTERBUTTON TO SAVE THE SETTING AND RETURN TO NORMAL OPERATION. TO SPECIFY THE NARROWBAND SENSOR,PRESS THE LEFT (DOWN) BUTTON THE METER’S POINTER WILL SWING TO A 9 O’CLOCK POSITION. PRESSES THECENTER MODE BUTTON TO SAVE THE SETTING AND RETURN TO NORMAL OPERATIONS

OPTION:RESTORE FACTORY DEFAULT: While in PEAK PLAYBACK, MAin Menu, press andhold both the CENTER and RIGHT buttons for 5 seconds. The dial pointer will step 5 times and return tozero (0). All user programmed setting will be erased and the gauge will return to NORMAL OPERA-TION.

OPTION :DEMO MODE: Displays the features of the meter. The pointer goes up and down thescale, the dial colors change and the HI, LOW and PEAK warning indicators light. The DEMO MODEdoes not time out. If the gauge is turned off in the DEMO MODE, it will start up in the DEMO MODE.Press the “Mode” button to return the gauge to NORMAL operation.

OPTION :POINTER BRIGHTNESS MODE: The “Down” and “Up” buttons adjust the dialpointer brightness to blend in with original manufacturer’s gauges and the owner’s requirements.Press the “Mode” button to return the gauge to NORMAL/DIAL BRIGHTNESS..

Programming Instructions for : Air/Fuel Ratio2 1/16” Monitor & Controller

3

Page 6: FlowChartProgrammingInstructionsfor:Air/FuelRatioGauge 2 1 ...€¦ · PRESS BOTH ProParts,LLC • POBox360• AnnapolisJunction MD • 20701 B • sales@ProPartsLLc.com • ph:3014907700

ProParts, LLC • PO Box 360 • Annapolis Junction MD • 20701www.ProPartsLLc.com • [email protected] • ph: 301 490 7700 • fax: 301 490 3700

GAUGE CRITICAL CONDITION

ALERT/OUTPUT GUIDE

PROGRAMMING INFORMATION:• TO RESET THE PROGRAM TO NORMAL OPERATION FROM ANY MODE PRESS THE “UP” AND“DOWN” BUTTONS SIMULTANEOUSLY. THIS SOFT RESET CANCELS THE INFORMATION YOUPROGRAMMED IN THAT MODE ONLY AND RETURN YOU TO NORMAL OPERATION.

• THE FACEPLATE WILL “FLASH” WHEN BUTTONS ARE DEPRESSED TO ACKNOWLEDGE COMMANDS.

• PROGRAMMING ERRORS WILL BE SIGNALLED BY FLASHING THE FACEPLATE LIGHTING “PURPLE”,“BLUE”, “GREEN” THEN “ORANGE”.

• IF PROGRAMMING IS INACTIVE FOR 120 SECONDS THE MODE WILL TIME OUT AND THE GAUGEWILL RETURN TO NORMAL OPERATION, EXCEPT FOR IN THE DEMONSTRATION MODE. THE DEMOMODE WILL NOT TIME OUT UNTIL THE CENTER “MODE” BUTTON IS PRESSED. IF THE GAUGE ISTURNED OFF IN THE DEMO MODE, IT WILL START-UP IN THE DEMO MODE.

• TO RESTORE FACTORY DEFAULTS, PRESS THE “MODE” BUTTON ONCE TO ENTER THE PEAKPLAYBACK. THEN PRESS AND HOLD THE “MODE” AND “UP” BUTTONS FOR FIVE SECONDS. YOURPROGRAMMING WILL BE ERASED BUT FACTORY PROGRAM WILL NOT BE AFFECTED.

Programming Instructions for : Air/Fuel Ratio2 1/16” Monitor & Controller

4

GAUGE TYPE

TEMPERATURE

PRESSURE

TACHOMETER

PYROMETER

NITROUS OXIDE PRESSURE

BOOST PRESSURE

AIR/FUEL

VOLTMETER

ALERT FLASHES “RED”

HIGH

LOW

HIGH

HIGH

LOW

HIGH

LOW

LOW

Patent Numbers 7,278,749 and 7,612,660Additional Patents Pending

Page 7: FlowChartProgrammingInstructionsfor:Air/FuelRatioGauge 2 1 ...€¦ · PRESS BOTH ProParts,LLC • POBox360• AnnapolisJunction MD • 20701 B • sales@ProPartsLLc.com • ph:3014907700

Wiring Installation Instructions for : Air/Fuel Ratio2 1/16” Gauge

ProParts, LLC • PO Box 360 • Annapolis Junction MD • 20701www.ProPartsLLc.com • [email protected] • ph: 301 490 7700 • fax: 301 490 3700

SPEK PRO™ AIR/FUEL RATIO GAUGE

FEATURES:SPEK PERFORMANCE GAUGE FEATURES:

• INTELLIGENT ELECTRICAL GAUGES.

• GAUGES ARE PROGRAMMED THROUGH COMMAND KEYS ON FACEPLATE.

• STEPPER MOTOR DRIVES THE GAUGE POINTER OVER A 280 DEGREE SWEEP.

• WIDE-ANGLE-DIAL™ HAS A 15% LARGER VIEWING AREA ON A 2 1/16” GAUGE.

• PROGRAMMABLE 7 COLOR DIAL AND RED POINTER ILLUMINATION.

• OPTIONAL OUTPUT CONTROL MODULE.

IMPORTANT:

1 THE AIR/FUEL GAUGE WILL MONITOR MOST FACTORY NARROW OR WIDE BAND SENSORS. IFREQUIRED, THE MODEL 13116, NARROW BAND AIR/FUEL SENSOR CAN BE INSTALLED.

2 SENSOR MUST BE IMMERSED IN EXHAUST FROM ALL CYLINDERS FOR AN ACCURATE READING.

3 MOUNT SENDER IN THE PIPE JUST BELOW THE MANIFOLD AND AS TO CLOSE THE CYLINDERHEAD IF POSSIBLE. THIS WILL PERMIT THE SENSOR TO REACH OPERATING TEMPERATURE.

1

PACKAGE CONTAINS:

• Air/Fuel Ratio Gauge

• J1 Wiring Harness

• Mounting Cup (required for dash installation)

• (1) Neoprene EDPM Grommet

OPTIONAL:

• Air/Fuel Sender narrow band (0 - 1.1volts)

• Output Control Modules (Part #’s 14820, 14826,14829)

Page 8: FlowChartProgrammingInstructionsfor:Air/FuelRatioGauge 2 1 ...€¦ · PRESS BOTH ProParts,LLC • POBox360• AnnapolisJunction MD • 20701 B • sales@ProPartsLLc.com • ph:3014907700

INSTALLATION INSTRUCTIONS:

1 DISCONNECT NEGATIVE (-) BATTERY TERMINAL.

2 VARIOUS MOUNTING SOLUTIONS ARE PRESENTED BY PROPARTS, LLC ON THEIR WEBSITE ATwww.ProPartsLLc.comDASH INSTALLATION: SELECT LOCATION IN THE DASH TO MOUNT GAUGE AND CUT A 2 1/16”HOLE. USE A FILE TO INCREASE THE HOLE SIZE IF REQUIRED. BE SURE THERE IS SUFFICIENTROOMBEHIND THE HOLE FOR THE METER CASE AND THE CONNECTORS YOU WILL USE.

3 IF A SUITABLE HOLE IN THE FIRE WALL IS NOT AVAILABLE, CUT AN 11/16” HOLE.

4 GROMMET MUST BE CUT TO PERMIT INSTALLATION OF WIRING HARNESS. (SEE DIAGRAM 1)

5 INSTALL THE GROMMMET AND MOUNTING CUP ON THE WIRING HARNESS AS SHOWN IN DIA-GRAM 1. GROMMET IS FOR THE HOLE IN THE FIREWALL.

6 DO NOT CONNECT WIRING HARNESS TO THE GAUGE UNTIL THE OTHER CONNECTIONS HAVEBEEN MADE AND TESTED.

7 IF ADDING AN OXYGEN SENSOR SELECT A LOCATION FOR MOUNTING THE SENDER IN THE PIPEJUST BELOW THE MANIFOLD. THIS IS WHERE THE EXHAUST FROM ALL THE CYLINDERS CAN BEMONITORED, AND THE SENSOR WILL QUICKLY REACH OPERATING TEMPERATURE.

8 DRILL A 7/8” HOLE IN THE EXHAUST PIPE AND WELD IN A BOSS ADAPTER.

9 IF NEEDED, INSTALL BUSHING ON THE SENDER.

10 CLEAN THREADS IN MOUNTING FITTING AND SCREW SENDER UNIT HAND TIGHT.

11 WITH WRENCH, TIGHTEN SENDER INTO BLOCK UNTIL SECURE. DO NOT OVERTIGHTEN. TESTALL FITTINGS FOR LEAKS.

12 CONNECT THE RED (+12 VOLT SUPPLY) WIRE TO “ON” CIRCUIT THAT GETS POWER WHEN THEIGNITION IS TURNED ON. THIS CIRCUIT MUST BE FUSED BEFORE THE IGNITION SWITCH. USE A5 AMP FAST ACTING FUSE.

13 CONNECT THE BLACK WIRE TO A GOOD GROUNDING POINT ON THE CAR’S CHASSIS.

14 CONNECT THE WHITE WIRE TO THE DIMMER VOLTAGE GOING TO THE DASH LIGHTS. THISWILL CAUSE THE METER BRIGHTNESS TO TRACK THE BRIGHTNESS OF THE REST OF THE INDICA-TORS.

15 CONNECT THE APPROPRIATE SENSOR SIGNAL WIRE.

16 PLUG THE WIRING HARNESS INTO THE GAUGE AND MOUNT IN DASH OR POD.

17 FOR DASH MOUNTING, ATTACH MOUNTING CUP OVER THE BACK OF THE GAUGE AND HANDTIGHTEN. DO NOT OVER-TIGHTEN. MOUNT CUP BEFORE INSTALLING GROMMET. FAILURE TO DO SO

ProParts, LLC • PO Box 360 • Annapolis Junction MD • 20701www.ProPartsLLc.com • [email protected] • ph: 301 490 7700 • fax: 301 490 3700 2

Wiring Installation Instructions for : Air/Fuel Ratio2 1/16” Gauge

Page 9: FlowChartProgrammingInstructionsfor:Air/FuelRatioGauge 2 1 ...€¦ · PRESS BOTH ProParts,LLC • POBox360• AnnapolisJunction MD • 20701 B • sales@ProPartsLLc.com • ph:3014907700

Black-Chassis Ground

Firewall

Grommet10-Pin Wiring

Harness & PlugGAUGE

5-Pin Wiring Harness3-Pin Wiring Harness

CUP

Grommet

Red-12VIgnition Switch

White-12VDash Lighting

HeadlightSwitch

Fuse

+12VDC

85

86

87A

30

7

GaugePIN 8 Output/Purple

Optional:Output ControlModule Part # 14820

OPTIONAL PART# 14820OUTPUT CONTROL MODULE:ALL SPEK GAUGES HAVE APROGRAMMABLE LIMIT SETTING.WHEN A SETTING IS TRIPPED,AN OUTPUT SIGNAL ISGENERATED. THIS CAN BEUSED TO SWITCH ON ARUGGED 40 AMP RELAYTO ACTIUVATE A TRANSMISSIONOIL COOLING FAN,LOW OIL, ENGINE KILL,ALARMS, ETC.

WARNING: OUTPUT CONTROL MODULENOT TO EXCEED 1.5 AMPS AT 12 VOLTS DC.WARRANTY WILL BE VOID IF INCREASEDOUTPUT VOLTAGE OR CURRENT IS APPLIED.

CAUTION: 12 VOLT DC POWERMUST BE CONNECTED TO THEIGNITION POWER AFTER THE FUSE.

Connector

OEM Oxygen Sensor(Not supplied by ProParts)

SIGNALHEATER GROUNDHEATER

CAUTION: IF ADDING AN OXYGEN SENSORDO NOT REMOVE EXISTING FSCTORY SENSOR.USE AN ALTERNATIVE LOCATION. IF FACTORYSENSOR IS REMOVED ECU MAY ACTIVATE AFAULT LIGHT.

WARNING: PERMANENT DAMAGE TOTHE AIR/FUEL SENDER WILL RESULTIF USED WITH LEAD GASOLINE ORFUEL ADDITIVES CONTAINING LEAD.UNDERCOATING, ANTIFREEZE, OR OILON THE OUTSIDE SURFACE OF THESENDER CAN DESTROY IT

WARNING: DO NOT CONNECT AN OHMMETER TO THE SENSOR. DO NOT APPLYPOWER OR GROUND. ONLY TEST SENSORWITH A HIGH IMPEDENCE DIGITAL METER(10 MEGA OHMS OR HIGHER) TO READOUTPUT VOLTAGE

ATo Output

Control Module

A

To RedIgnition Switch

+12VDC

WILL TWIST WIRES CAUSING A SHORT CIRCUIT.

18 POWER UP THE GAUGE AND INSPECT ALL CONNECTIONS. IF GAUGE IS OPERATING NORMALLY,PROCEED TO THE “PROGRAMMING MANUAL.”

ProParts, LLC • PO Box 360 • Annapolis Junction MD • 20701www.ProPartsLLc.com • [email protected] • ph: 301 490 7700 • fax: 301 490 3700 3

Wiring Installation Instructions for : Air/Fuel Ratio2 1/16” Gauge

© 2007

DIAGRAM 1

PATENTED WIDE ANGLE DIALFOR SUPERIOR VISIBILITYU.S PATENT #7,278,749

Page 10: FlowChartProgrammingInstructionsfor:Air/FuelRatioGauge 2 1 ...€¦ · PRESS BOTH ProParts,LLC • POBox360• AnnapolisJunction MD • 20701 B • sales@ProPartsLLc.com • ph:3014907700

Wiring Installation Instructions for : Air/Fuel Ratio2 1/16” Gauge

ProParts, LLC • PO Box 360 • Annapolis Junction MD • 20701www.ProPartsLLc.com • [email protected] • ph: 301 490 7700 • fax: 301 490 3700 4

THERE ARE THREE SECTIONS TO THIS MANUAL: WIRING INSTRUCTIONS, PROGRAMMINGINSTRUCTIONS AND FLOW CHART PROGRAMMING INSTRUCTIONS. PLEASE READ EACHSECTION CAREFULLY BEFORE ATTEMPTING TO INSTALL OR OPERATE THIS PRODUCT.

WARNING:

•ALL INSTRUCTIONS IN THIS MANUAL MUST BE FOLLOWED TO INSURE SAFE INSTALLA-TION AND OPERATION OF THIS PRODUCT.• NEVER DISASSEMBLE MODIFY OR TAMPER WITH THIS PRODUCT. THIS COULD CAUSEDAMAGE AND MAKE THEM UNSAFE TO USE. TAMPERING WITH THE PRODUCT WILL VOIDTHE LIMITED WARRANTY.• INSTALLATION MUST BE PERFORMED BY AN EXPERIENCED AUTOMOTIVE TECHNICIAN.• INSTALLER MUST USE SAFETY GLASSES.• DISCONNECT THE NEGATIVE BATTERY TERMINAL BEFORE BEGINNING INSTALLATION.PROPARTS LLC IS NOT RESPONSIBLE FOR DAMAGE TO ENGINE, VEHICLE OR UNIT CAUSEDBY ELECTRICAL SHORTS.• DURING INSTALLATION, DO NOT INTERFERE WITH ANY EXISTING CONNECTIONS ORWIRES.• ALL ELECTRICAL CONNECTIONS USE SOLDER LESS CONNECTORS AND INSULATE ALLCONNECTIONS WITH ELECTRICAL TAPE.

DIAGRAM 2

WIRING FOR 2 1/16” SPEK AIR/FUEL RATIO GAUGE

PIN 12 Ground/BlackPIN 8 +12 VDC/Red

PIN 5 1.9 Amp Fet Output/ PurplePIN 6 Dimmer Input/White

PIN 2 Signal Input/Blue

1 2 3 4 5 67 8 9 10 11 12

J1

Page 11: FlowChartProgrammingInstructionsfor:Air/FuelRatioGauge 2 1 ...€¦ · PRESS BOTH ProParts,LLC • POBox360• AnnapolisJunction MD • 20701 B • sales@ProPartsLLc.com • ph:3014907700

ProParts, LLC • PO Box 360 • Annapolis Junction MD • 20701www.ProPartsLLc.com • [email protected] • ph: 301 490 7700 • fax: 301 490 3700 5

Wiring Installation Instructions for : Air/Fuel Ratio2 1/16” Gauge

• AVOID WIRING NEAR ENGINE, EXHAUST SYSTEM, TURBINE OR ANY AREA THAT MAY RE-SULT IN DAMAGE.• DISCONTINUE USE OF THE PRODUCT IF SMOKE OR A STRANGE ODOR IN PRESENT.

CAUTION

• PROPARTS LLC IS NOT RESPONSIBLE FOR INCORRECT INSTALLATION OR PROGRAMMINGOF SPEK™ GAUGES OR CONTROLLERS.• SPEK™ GAUGES AND CONTROLLERS ARE DESIGNED FOR 12V DC ELECTRICAL SYSTEMSWITH A NEGATIVE GROUND.• DO NOT ADJUST THE GAUGES OR GAUGE PROGRAM WHILE DRIVING• OBEY ALL RULES AND REGULATIONS OF HIGHWAY AND STREET DRIVING.• INSTALL SENSOR AND WIRE AWAY FROM HIGH HEAT AND / OR VIBRATION AREAS.• USE CARE WHEN CONNECTING OR DISCONNECTING THE WIRING HARNESS. PULL OUTEACH CONNECTOR WHILE PRESSING THE LOCK OF THE CONNECTOR FIRMLY.• IF THE BATTERY TERMINAL IS DISCONNECTED, THE AUDIO, CLOCK AND OTHER MEMORYDATA MAY BE LOST. THE NECESSARY DATA WILL HAVE TO BE RESET AFTER INSTALLA-TION.

ProParts, LLC Limited Warranty:

ProParts, LLC warrants all merchandise against defects in factory workmanship and material for 12 months fromdate of original purchase. Proof of purchase is required: otherwise the warranty period shall default to 12 monthsfrom date of manufacture as indicated by the date code on the product. This warranty applies to the first retailpurchaser and covers only those products exposed to normal use or service. This warranty excludes items usedfor a purpose for which it is not designed, or which has been altered in any way that would be detrimental to theperformance or life of the product or misapplication, misuse, negligence or accident. When it is determined byProParts, LLC after examination that a product is defective, ProParts, LLC will repair, replace or issues credit forany defective product through the original selling dealer or on a direct bases. In no event shall this warranty ex-ceed the original price of the product. ProParts, LLC assumes no responsibility for diagnosis, removal and/ or in-stallation labor, loss of vehicles use, loss of time, inconvenience or any other consequential expense. ProParts,LLC disclaims any liability for consequential damages due to breach of any written or implied warranty on allproducts manufactured by ProParts LLC. Warranty is valid only for original purchaser and is not transferable. ThisWarranty gives you specific legal rights, and may also have other rights which may vary from state to state. Cus-tomer agrees to insure the Product or assume the risk of loss or damage in transit, to prepay shipping charges toProParts, and to use the original shipping container or equivalent.

Important Disclaimer:This product may not be lawful for use on public roadway. No warranty is made or implied regarding the legalityof offered products when they are installed in a motor vehicle in any particular state, province or municipality. Itis the user’s responsibility to determine the legality of any automotive alterations made in connection to productsmade by, obtained from or distributed by ProParts, LLC.

The purchaser or user of any products, sold or manufactured by ProParts, LLC assumes all risk related to and/ orarising from the ownership or use of said product and agrees to indemnify and hold ProParts, LLC harmless fromany and all claims brought by any person or entity against ProParts, LLC related to and/or arising from ownershipand/or use of said products.

Return Goods Authorization:Warranty returns will only be accepted by ProParts, LLC when accompanied by a valid Return Goods Authorization(RGA) number. Products must be received by ProParts, LLC within 30 days of the date the RGA is issued. Before aRGA can be issued, the installer or end user must contact ProParts, LLC Technical Department to discuss the

Page 12: FlowChartProgrammingInstructionsfor:Air/FuelRatioGauge 2 1 ...€¦ · PRESS BOTH ProParts,LLC • POBox360• AnnapolisJunction MD • 20701 B • sales@ProPartsLLc.com • ph:3014907700

ProParts, LLC • PO Box 360 • Annapolis Junction MD • 20701www.ProPartsLLc.com • [email protected] • ph: 301 490 7700 • fax: 301 490 3700 6

Wiring Installation Instructions for : Air/Fuel Ratio2 1/16” Gauge

problem. Any out of warranty ProParts, LLC products can be returned for repair. There is a minimum charge of$50.00 dollars for inspection and diagnosis. ProParts, LLC will provide an estimate of repairs and receive writtenauthorization before repairs are made to the product.Disclaimer:Performance products are designed to increase engine power and create stress not engineered by the OriginalEquipment Manufacture (OEM). This could result in damage to the engine and related systems. Purchaser usesthis product at his own risk. ProParts, LLC, its agents, employees, and owners shall not be under any liabilitywhether or not resulting from any negligence or content of information supplied for any damage or loss resultingfrom this information.Non-Warranty Repair/RetestProducts returned due to damage or misuse and Product retested with no problem found are subject torepair/retest charges. A purchase order or credit card number and authorization must be provided in order to ob-tain an RMA (Return Merchandise Authorization) number prior to returning product.

U.S. Patent # 7,612,660U.S. Patent # 7, 278,749Additional Patents Pending