for lease premier office & technology park 4050 premier … · 2018. 8. 3. · 4050 premier...

3
Part of the CBRE affiliate network www.cbre.us/triad FOR LEASE PREMIER OFFICE & TECHNOLOGY PARK 4050 PREMIER DRIVE HIGH POINT, NC 27265 PROPERTY OVERVIEW Premier Office & Technology Park is an office park located in the Greensboro airport submarket. The park consists of two office buildings totaling 106,356 SF. The buildings are ideal for office, biotechnology or medical users. Excellent location along Highway 68 with close proximity to I-40, Wendover Ave & PTI Airport. BUILDING OVERVIEW + MAJOR RENOVATIONS UNDERWAY + Total Building: 50,743 SF + Available: 50,743 SF + Year Built: 1997 + Zoning: CP + Hotels, Restaurants, Banks & Retail Nearby + Easy Access to I-40, I-73, US-421, Highway 68 and Wendover Ave CONTACT US DODSON SCHENCK, SIOR Managing Director +1 336 478 0234 [email protected] JOE STANLEY, CCIM Senior Associate +1 336 369 5802 [email protected]

Upload: others

Post on 10-Mar-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FOR LEASE PREMIER OFFICE & TECHNOLOGY PARK 4050 PREMIER … · 2018. 8. 3. · 4050 PREMIER DRIVE HIGH POINT, NC 27265 PROPERTY OVERVIEW Premier Office & Technology Park is an office

Part of the CBRE affiliate networkPart of the CBRE affiliate network

www.cbre.us/triad

FOR LEASE

PREMIER OFFICE & TECHNOLOGY PARK 4050 PREMIER DRIVE HIGH POINT, NC 27265

PROPERTY OVERVIEWPremier Office & Technology Park is an office park located in the Greensboro airport submarket. The park consists of two office buildings totaling 106,356 SF. The buildings are ideal for office, biotechnology or medical users. Excellent location along Highway 68 with close proximity to I-40, Wendover Ave & PTI Airport.

BUILDING OVERVIEW

+ MAJOR RENOVATIONS UNDERWAY + Total Building: 50,743 SF + Available: 50,743 SF + Year Built: 1997 + Zoning: CP + Hotels, Restaurants, Banks & Retail Nearby + Easy Access to I-40, I-73, US-421, Highway 68 and Wendover Ave

CONTACT US

DODSON SCHENCK, SIORManaging Director+1 336 478 [email protected]

JOE STANLEY, CCIMSenior Associate+1 336 369 [email protected]

Page 2: FOR LEASE PREMIER OFFICE & TECHNOLOGY PARK 4050 PREMIER … · 2018. 8. 3. · 4050 PREMIER DRIVE HIGH POINT, NC 27265 PROPERTY OVERVIEW Premier Office & Technology Park is an office

Part of the CBRE affiliate networkPart of the CBRE affiliate network

www.cbre.us/triad

4050 PREMIER DRIVE HIGH POINT, NORTH CAROLINA

FOR LEASE

FLOOR PLANS

FIRST FLOOR

SECOND FLOOR1 2 3 4 5 6 7

A

C

D

F

MEN'S TOILET

WOMEN'S TOILET

EWC-1

KEYED NOTES THIS SHEET

EXTEND NEW 2" SAN PIPING AND CONNECT TOEXISTING SAN PIPING IN THIS AREA. VERIFYEXACT LOCATION, SIZE, INVERT, AND DIRECTIONOF FLOW OF EXISTING PIPING IN FIELD.

1

EXTEND NEW 1-1/2" VENT PIPING AND CONNECT TOEXISTING VENT PIPING IN THIS AREA. VERIFY EXACTLOCATION AND SIZE OF EXISTING PIPING IN FIELD.

EXTEND NEW 1/2" CW PIPING AND CONNECT TOEXISTING CW PIPING IN THIS AREA. VERIFY EXACTLOCATION AND SIZE OF EXISTING PIPING IN FIELD.

2

3

P.C. PLUMBING CONTRACTOROVERFLOW ROOF DRAIN

MTD MOUNTEDM.C. MECHANICAL CONTRACTOR

IE, INV ELEV INVERT ELEVATIONG.C. GENERAL CONTRACTORFLR FLOORFFE FINISHED FLOOR ELEVATION

EX, EXIST, (E) EXISTINGETR EXISTING TO REMAINE.C. ELECTRICAL CONTRACTORDN DOWN

CONT CONTINUATIONCONN CONNECT OR CONNECTIONCLG CEILING

BLDG BUILDINGBLW BELOW

AHAP AS HIGH AS POSSIBLEAFF ABOVE FINISHED FLOOR

ORD

ABV ABOVE

OR PIPE UP

OR PIPE DOWN

POINT OF CONNECTION TO EXISTING

SANITARY PIPING (SAN)

VENT PIPING (V)

DOMESTIC COLD WATER PIPING (CW)

PLUMBING LEGENDPIPING

SYMBOLS

ABBREVIATIONS

PIPE CONTINUES

BALL VALVE (NORALLY OPEN)

12

1. SEE FIXTURE SCHEDULE THIS SHEET FOR SIZES OFDOMESTIC WATER AND SANITARY WASTE AND VENTCONNECTIONS TO INDIVIDUAL FIXTURES.

2. MINIMUM SIZE FOR SANITARY WASTE AND VENT PIPINGBELOW GROUND SHALL BE 2".

3. ALL DOMESTIC WATER PIPING SHOWN ON THIS SHEETSHALL BE RUN ABOVE CEILINGS IN AREAS WITHCEILINGS AND SHALL BE RUN AS HIGH AS POSSIBLE INAREAS WITHOUT CEILINGS, UNLESS OTHERWISENOTED.

4. ALL SANITARY VENT PIPING SHOWN ON THIS SHEETSHALL BE RUN ABOVE CEILINGS IN AREAS WITHCEILINGS AND SHALL BE RUN AS HIGH AS POSSIBLE INAREAS WITHOUT CEILINGS, UNLESS OTHERWISENOTED; ALL SANITARY WASTE PIPING SHOWN ON THISSHEET SHALL BE RUN BELOW FLOORS, UNLESSOTHERWISE NOTED.

5. THE PLUMBING CONTRACTOR SHALL FIELD VERIFYEXISTING CONDITIONS INCLUDING DIRECTION OFFLOW, INVERTS, AND TIE-IN LOCATIONS PRIOR TOROUTING ANY PIPING. SAWCUT EXISTING SLAB, WALL,OR CEILING CONSTRUCTION AS REQUIRED. AREAS TOBE SAWCUT SHALL BE APPROVED BY ARCHITECTPRIOR TO CUTTING. ALL SAWCUT AND ALTEREDSURFACES SHALL BE FILLED, PATCHED, PAINTED, ANDREPAIRED TO MATCH ADJACENT SURFACES.

GENERAL NOTES THIS SHEET

SCALE: 1/8" = 1'-0"

PLUMBING FLOOR PLAN1P001

PLUMBING GENERAL NOTES

GENERAL REQUIREMENTS:

1. GENERAL AND SPECIAL CONDITIONS: GENERAL AND SPECIAL CONDITIONS AREHEREBY MADE AN INTEGRAL PART OF THIS DIVISION OF THE SPECIFICATIONSINSOFAR AS SAME ARE APPLICABLE TO THE WORK UNDER THIS DIVISION ANDUNLESS OTHERWISE SPECIFIED.

2. SCOPE: PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT REQUIRED FOR THECOMPLETION AND OPERATION OF ALL SYSTEMS IN THIS SECTION OF WORK.

3. CODE COMPLIANCE: ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALLAUTHORITIES HAVING JURISDICTION, BUILDING DEPARTMENTS, AND DEPARTMENT OFHEALTH. APPLICABLE NATIONAL, STATE, AND LOCAL CODES, LAWS, ANDREGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK SHALL BEINCORPORATED INTO AND MADE A PART OF THESE CONTRACT DOCUMENTS ANDSPECIFICATIONS. THE CONTRACTOR IS TO NOTIFY THE ARCHITECT/ENGINEER OFANY WORK OR MATERIALS WHICH VIOLATE ANY OF THE ABOVE CODES, LAWS, ORREGULATIONS. ANY WORK DONE BY THE CONTRACTOR CAUSING SUCH A VIOLATIONSHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE AND AT NO EXPENSE TOTHE OWNER.

4. PERMITS: APPLY FOR AND PAY FOR ALL NECESSARY PERMITS, FEES, ANDINSPECTIONS REQUIRED BY ANY PUBLIC AUTHORITY HAVING JURISDICTION.

5. WARRANTY: PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT UNDER THISSECTION OF THE SPECIFICATIONS WITH A ONE YEAR WARRANTY FROM THE DATE OFACCEPTANCE OF WORK BY THE OWNER.

6. RECORD DRAWINGS: CONTRACTOR SHALL MAINTAIN AN ACCURATE RECORD OF ALLAS-BUILT CONDITIONS DURING CONSTRUCTION AND TURN OVER ONE COPY EACH TOTHE OWNER AND THE ARCHITECT AFTER COMPLETION.

7. OPERATING MANUALS: CONTRACTOR SHALL FURNISH TO THE OWNER 3 SETS OFOPERATION AND MAINTENANCE MANUALS FOR ALL MAJOR PIECES OF EQUIPMENT.

8. COORDINATION: VERIFY ALL ROUGH-IN LOCATIONS AND COORDINATE PIPING ANDEQUIPMENT LOCATIONS WITH WORK UNDER OTHER DIVISIONS OF THESPECIFICATIONS TO AVOID CONFLICTS. CONTRACTOR MUST COORDINATE WITHOTHER TRADES FOR ALL STRUCTURES, PIPING, CONDUIT, DUCTWORK, LIGHTING, ETCTO PROPERLY BE INSTALLED. ANY CONFLICTS SHALL BE RESOLVED AT NO EXPENSETO THE OWNER.

9. FIELD VERIFICATION: FIELD VERIFY EXISTING CONDITIONS BEFORE STARTINGCONSTRUCTION AND NOTIFY THE ARCHITECT/ENGINEER OF RECORD OF ANYDISCREPANCIES BETWEEN THE CONSTRUCTION DOCUMENTS AND EXISTINGCONDITIONS, AND/OR ANY POTENTIAL PROBLEMS OBSERVED, BEFORE CONTINUINGWORK IN THE AFFECTED AREAS.

10. LABEL ALL PLUMBING PIPING WITH ADHESIVE PIPE LABELS INDICATING SERVICE ANDDIRECTION OF FLOW. PIPE LABELS SHALL BE LOCATED NEAR ALL BRANCHCONNECTIONS, NEAR ALL FLOOR AND WALL PENETRATIONS, AND AT MAXIMUMINTERVALS OF 25' ALONG EACH RUN.

11. PLUMBING SYSTEMS INCLUDE, BUT ARE NOT LIMITED TO:-PLUMBING FIXTURES AND EQUIPMENT-FIRE STOPPING-DOMESTIC WATER SYSTEM-SANITARY WASTE AND VENT SYSTEM

FIXTURES:

1. PROVIDE COMPLETE FIXTURES AND INCLUDE SUPPLIES, STOPS, VALVES, FAUCETS,DRAINS, TRAPS, TAILPIECES, ESCUTCHEONS, ETC. EXPOSED COPPER OR BRASSMATERIALS SHALL BE CHROME PLATED.

2. SEAL ALL EDGES OF PLUMBING FIXTURES IN CONTACT WITH FLOORS, WALLS, ORCOUNTERTOPS USING SANITARY-TYPE, ONE-PART, MILDEW RESISTANT SILICONESEALANT. MATCH SEALANT COLOR TO FIXTURE COLOR.

3. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS OF PLUMBINGFIXTURES.

FIRE STOPPING:

1. FIRE STOP ALL PENETRATIONS, BY PIPING OR CONDUITS, OF FIRE RATED WALLS,FLOORS, AND PARTITIONS. PROVIDE DEVICE(S) OR SYSTEM(S) WHICH HAS BEENTESTED AND LISTED AS COMPLYING WITH ASTM E-814 AND INSTALL IN ACCORDANCEWITH THE CONDITIONS OF THEIR LISTING. PROVIDE DEVICE(S) OR SYSTEM(S) WITHAN 'F' RATING EQUAL TO THE RATING OF THE ASSEMBLY BEING PENETRATED.

DOMESTIC WATER PIPING:

1. FURNISH AND INSTALL A COMPLETE SYSTEM OF DOMESTIC HOT AND COLD WATERSUPPLIES TO ALL FIXTURES AND/OR EQUIPMENT REQUIRING DOMESTIC WATERSUPPLIES.

2. DOMESTIC WATER PIPING BELOW GROUND: ASTM B 88 TYPE 'K' SOFT COPPER TUBEWITH WROT COPPER FITTINGS, AND BRAZED OR PRESSURE-SEALED JOINTS.

3. DOMESTIC WATER PIPING ABOVE GROUND: ASTM B 88 TYPE 'L' HARD COPPER TUBEWITH WROT COPPER FITTINGS, AND SOLDERED OR PRESSURE-SEALED JOINTS.

4. STERILIZE DOMESTIC WATER PIPING IN ACCORDANCE WITH THE AMERICAN WATERWORKS ASSOCIATION'S SPECIFICATIONS AND LOCAL HEALTH DEPARTMENTREGULATIONS.

5. INSULATE DOMESTIC WATER PIPING ABOVE GRADE (EXCEPT EXPOSEDCONNECTIONS TO PLUMBING FIXTURES) WITH 1" THICKNESS ENGINEERED POLYMERFOAM INSULATION, OR MINERAL-FIBER PREFORMED PIPE INSULATION WITHFACTORY-APPLIED ASJ.

6. DOMESTIC WATER PIPING INSULATION, JACKETS, COVERINGS, SEALERS, MASTICS,AND ADHESIVES SHALL NOT EXCEED A FLAME SPREAD RATING OF 25 AND A SMOKEDEVELOPED RATING OF 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84.

7. ALL PIPE INSULATION SHALL RUN CONTINUOUSLY THROUGH WALLS AND PARTITIONS.

8. DO NOT INSTALL DOMESTIC WATER PIPING IN AREAS SUBJECT TO FREEZINGTEMPERATURES. INSTALL DOMESTIC WATER PIPING IN EXTERIOR WALLS ON THECONDITIONED SIDE OF THE WALL INSULATION. INSTALL DOMESTIC WATER PIPING INATTIC SPACES BELOW THE ATTIC INSULATION.

9. SHUT-OFF VALVES SHALL BE TWO-PIECE, BRONZE, FULL PORT, BALL TYPE,MANUFACTURED BY APOLLO OR NIBCO. PROVIDE SHUT-OFF VALVES WHEREINDICATED ON THE DRAWINGS. INSTALL VALVES IN A LOCATION THAT PERMITSACCESS FOR SERVICE AND OPERATION WITHOUT DAMAGE TO THE BUILDING ORFINISHED MATERIALS. PROVIDE ACCESS DOORS IF REQUIRED.

10. PROVIDE A PRESSURE REDUCING VALVE WITH STRAINER AT THE SERVICE ENTRANCETO THE BUILDING IF THE INCOMING WATER PRESSURE EXCEEDS 80 PSI.

11. PROTECT COPPER PIPING AGAINST CONTACT WITH DISSIMILAR METALS. ALLHANGERS, SUPPORTS, ANCHORS, AND CLIPS SHALL BE COPPER OR COPPER-PLATED.

SANITARY WASTE AND VENT PIPING:

1. FURNISH AND INSTALL COMPLETE SYSTEMS OF SANITARY WASTE AND VENT PIPINGFROM ALL PLUMBING FIXTURES AND/OR EQUIPMENT REQUIRING WASTE AND VENTCONNECTIONS. ALL WASTE AND VENT PIPING SHALL BE CONCEALED IN THEBUILDING CONSTRUCTION WHERE POSSIBLE.

2. SANITARY WASTE AND VENT PIPING BELOW GROUND: ASTM A 74, SERVICE WEIGHT,HUB AND SPIGOT, CAST IRON SOIL PIPE AND FITTINGS; AND GASKETED JOINTS. ALLPIPE AND FITTINGS SHALL BE MARKED WITH THE COLLECTIVE TRADEMARK OF THECAST IRON SOIL PIPE INSTITUTE, AND LISTED BY NSF INTERNATIONAL.

3. SANITARY WASTE AND VENT PIPING ABOVE GROUND: ASTM A 888 AND CISPI 301,HUBLESS, CAST IRON SOIL PIPE AND FITTINGS; AND HEAVY DUTY SHIELDED,STAINLESS STEEL COUPLINGS. ALL PIPE AND FITTINGS SHALL BE MARKED WITH THECOLLECTIVE TRADEMARK OF THE CAST IRON SOIL PIPE INSTITUTE, AND LISTED BYNSF INTERNATIONAL.

4. IF PERMITTED BY LOCAL CODES, ASTM D 2665 SCHEDULE 40 SOLID WALL PVC PIPEWITH ASTM D 3311 SCHEDULE 40 SOCKET-TYPE FITTINGS MAY BE USED FORSANITARY WASTE AND VENT PIPING ABOVE AND BELOW GROUND. PVC PIPINGINSTALLED IN RETURN AIR PLENUMS MUST BE PROTECTED WITH 3M FIRE BARRIERPLENUM WRAP 5A+, OR SIMILAR PRODUCT.

5. INVERT ELEVATIONS SHALL BE ESTABLISHED AND VERIFIED BEFORE SANITARYPIPING IS INSTALLED IN ORDER THAT PROPER SLOPES WILL BE MAINTAINED. SLOPESANITARY PIPING 2-1/2" AND SMALLER AT 1/4" PER FOOT MINIMUM, AND SLOPESANITARY PIPING 3" AND LARGER AT 1/8" PER FOOT MINIMUM.

6. WHERE SANITARY PIPING IS EXPOSED IN TOILET ROOMS, PROVIDE CHROME-PLATEDBRASS PIPING WITH MATCHING STOPS AND ESCUTCHEONS. PROVIDE REMOVABLETRAPS WITH INTEGRAL CLEANOUT PLUG FOR ALL LAVATORIES AND SINKS.

7. INSTALL CLEANOUTS IN A LOCATION THAT PERMITS ACCESS FOR SERVICE WITHOUTDAMAGE TO THE BUILDING OR FINISHED MATERIALS. CLEANOUT PLUGS SHALL BEINSTALLED IN ACCORDANCE WITH PLUMBING CODE REQUIREMENTS.

8. ALL INDIRECT WASTE PIPING SHALL DISCHARGE THROUGH AN AIR GAP INTO ANAPPROVED WASTE RECEPTOR. THE AIR GAP BETWEEN THE INDIRECT WASTE PIPEAND THE FLOOD LEVEL RIM OF THE WASTE RECEPTOR SHALL BE A MINIMUM OFTWICE THE EFFECTIVE OPENING OF THE INDIRECT WASTE PIPE.

PLUMBING FIXTURE SPECIFICATIONS AND CONNECTION SCHEDULE

MARK FIXTURE TYPEPIPE SIZES

SAN VENT CW HW SPECIFICATIONSMATERIAL

EWC-1ELECTRIC

WATERCOOLER

WALL MOUNTEDADA HEIGHT 1-1/2" 1-1/2" 1/2" -STAINLESS

STEEL

FIXTURE: ELKAY MODEL LZS8WSSP, BOTTLE FILLING STATION, BARRIER-FREE, SELF-CONTAINED, 8.0 GPH, EASY-TOUCH CONTROLS ON FRONT AND SIDES, ONE PIECE STAINLESS STEEL TOPS WITH INTEGRAL DRAINS, FLEXIBLE BUBBLERS, STAINLESS STEEL LOWER SHROUDS, WATER FILTER WITH LED FILTER MONITOR.TRAP: McGUIRE MODEL 8912CNC 1-1/2" x 1-1/2" 17 GAUGE CHROME PLATED CAST BRASS P-TRAP.SUPPLY: McGUIRE MODEL LFST13, POLISHED CHROME PLATED CAST BRASS WHEEL HANDLE STRAIGHT STOP, 1/2" IPS INLET, 3/8" COMPRESSION OUTLET.

3

TRUE

PROJECT NO:

SHEET IDENTIFIER

CHARLOTTE,NC

RICHMOND, VA

CONSULTANT

P.I.C.

P MGR.

P ARCH.

DESIGN BY

JOB CAPTAIN

DRAWN BY

CHECKED BY

SHEET TITLE

2700 East Cary StreetRichmond, VA 23223

(T) 804-287-8200 (F) 804-287-8279www.odell.com

ISSUE DATE DESCRIPTION08/21/2017

FULL SET ISSUES

ADDENDA OR MODIFICATION

CD CONSTRUCTION DOCUMENTS

5 4 3 2 1

5 4 3 2 1

AB

CD

AB

CD

7/18

/201

7 10

:47:

37 A

M\\o

dell.

com

\sha

red\

prod

uctio

n\40

94-0

01_C

BRE

- 405

0 Pr

emie

r Driv

e\E_

BIM

\E1_

Arch

itect

ural

\409

4-00

1_C

BRE_

Arch

02.rv

t

4050 PREMIER DRIVEHIGH POINT, NC 27265

4050 PREMIERDRIVE - 2ND FLOOR

CBRE

4094-001

C. ENTZMINGER

A. CUMMINS

S. GLERUM

A. CUMMINS

A. CUMMINS

2017 ODELL Associates, Inc., All Rights Reservedc

REVISION DATE DESCRIPTION

PRO FES SI ONAL

E N G I N E E R

SEAL037734

NO

RTH CAROLINA

MICHAEL J. SENUTA

PLUMBING2nd FLOOR PLAN

P001

MJS

SBC

PROJECT NO:

P.I.C.

P MGR.

P ARCH.

DESIGN BY

JOB CAPTAIN

ISSUE DATE DESCRIPTION08/22/2017

FULL SET ISSUES

ADDENDA OR MODIFICATION

CD BID/PERMIT DOCUMENTS

4094-001

G. GUPTE

A. CUMMINS

S. GLERUM

A. CUMMINS

A. CUMMINS

REVISION DATE DESCRIPTION

LOADING DOCK

UP 24R

UP 24R

XBG3

6

XBG3

6

220V

HW CW

XBS60

XBE3

6

XBE3

6

XBG3

6

XBG3

6

HW CW

XBG3

6

XBG3

6

XBG3

6

XBG3

6

HW CW

XBG3

6

XBG3

6

KOAPA48

XBG60

XBG3

6

XBG3

6

INFRAREDDRYER

PADDER

OVEN

DRYER

PRINT TABLE

PRESS

4 SECTIONSINK

BOIL BATHBY OWNER

HW S

STEAMER

PAD STEAMERRANGE

(HIGH EQUIP.)

(HIGH EQUIP.)

SCREEN SINK

PRINT/WOVEN LAB

KOAPA48

KOAPA48

KOAPA48

KOAPA48

KOAPA48

KOAPA48

KOAPA48

CW

A

HW

A S CW

SCW

CANOPY HOOD

RAPID

TEXOMAT

POLYMATFD

SDI DI

XBS60SS TROUGH

DI

XBS60SS TROUGH

SDIHW CW

FD

FD

FD

220V

220V

A CW

220V

220V

OVENTHERMOSOL

220V

INFRA. DYE 220V

220V

220V

220V 220V

220V

220V

TYPE "B"ISLAND BENCH

TYPE "C"ISLAND BENCH

1'-0" X 1'-0"SERVICE DROP

1'-0" X 1'-0"SERVICE DROP

TYPE "B"ISLAND BENCH

TYPE "B"ISLAND BENCH

MODIFIED

KOAPA48

KOAPA

KOAPA48

TYPE "C"ISLAND BENCH

TYPE "C"ISLAND BENCH

TYPE "B"ISLAND BENCH

BB18

TEXOMAT

TEXOMAT

TEXOMAT220V

220V

220V

220V

220V

220V

220V

220V

220V

36'-0

3/8"

25'-0

1/8" 21'- 2 1/8"

9'-2 7/

8"38'

-8 3/8

"39'

-2 5/8

"

220V

220V

220V

220V

220V

220V

STEAMER

EXTRACTOR

STEAMER

INFRA. DYE

4'

208V

FEC

FEC

FEC

FEC

FEC

FECFECFECFEC FEC

THE PROPOSED PROJECT DOES NOT MODIFY THE EXISTING LIFE SAFETY COMPONENTS

INCLUDING BUT NOT LIMITED TO RATED WALLS, EGRESS WIDTHS, TRAVEL DISTANCES AND

EXITS.

76'

144'

155'

TRUE

PROJECT NO:

SHEET IDENTIFIER

CHARLOTTE, NC

RICHMOND, VA

CONSULTANT

P.I.C.

P MGR.

P ARCH.

DESIGN BY

JOB CAPTAIN

DRAWN BY

CHECKED BY

SHEET TITLE

2700 East Cary StreetRichmond, VA 23223

(T) 804-287-8200 (F) 804-287-8279www.odell.com

ISSUE DATE DESCRIPTION08/22/2017

FULL SET ISSUES

ADDENDA OR MODIFICATION

CD BID/PERMIT DOCUMENTS

5 4 3 2 1

5 4 3 2 1

AB

CD

AB

CD

8/22

/201

7 8:

54:3

8 AM

C:\R

evit

Loca

l\409

4-00

1_C

BRE_

Arch

01_2

017_

YBC

E.07

@G

MAI

L.C

OM

.rvt

LIFE SAFETY PLAN -FIRST FLOOR

4050 PREMIER DRIVEHIGH POINT, NC 27265

4050 PREMIERDRIVE - 1ST FLOOR

GL101

CBRE

4094-001

G. GUPTE

G. GUPTE

A. CUMMINS

S. GLERUM

A. CUMMINS

A. CUMMINS

A. CUMMINS

2017

2S 2 HR SMOKE BARRIERTYPE 2SB3 U.O.I.

1S 1 HR SMOKE BARRIERTYPE 1SA3 U.O.I.

TYPICAL PARTITIONS

S SMOKE PARTITIONTYPE SA3 U.O.I.

-- NON FIRE RATED TYPE A3 U.O.I.a

1P 1 HR FIRE PARTITIONTYPE 1PA3 U.O.I.

1 1 HR FIRE BARRIERTYPE 1A3 U.O.I.

2 2 HR FIRE BARRIERTYPE 2B3 U.O.I.

-- EXISTING PARTITION

a

a

a

a

a

a

PARTITION RATINGS

FIRE EXTINGUISHER CABINET

BRACKET MOUNTED FIRE EXTINGUISHER

FEC

FE

FIRE PROTECTION

N

EXIT EGRESS SYMBOLS

16332"

0 EGRESS LOADEXIT CAPACITY (1005.1)CLEAR OPENING WIDTH

Space Function1

100 SF

101 OCC.

OCCUPANCY TYPE

CAPACITY RATE(NET/GROSS SF)AREAOCCUPANT LOAD

DIRECTIONAL ILLUMINATED EXIT SIGN

COMMON PATH OF TRAVEL

BUILDING EXIT

SUITE EXIT

BUILDING EXIT DISCHARGE

SUITE EGRESS INDICATOR

HE HORIZONTAL EXIT

74'(MAX - 75' - 0")

(MAX - 200' - 0")

(MAX - 100' - 0")

199'

99'

EGRESS LEGEND

ODELL Associates, Inc., All Rights Reservedc

1/16" = 1'-0" FIRST FLOOR - LIFE SAFETY PLANB5

REVISION DATE DESCRIPTION

08/22/2017

1ST FLOOR SPACE:

+ Available SF: 2,500 - 36,448 SF

+ Office Build Out to Suit Tenant Specs

+ 2,000 Amp Service

+ Secure Key Card Access

2ND FLOOR SPACE:

+ Available SF: 3,500 - 14,295 SF

+ Can subdivide to 3,500 SF

+ New Space and Finishes to Suit Tenant Specs

+ Ideal for Office, Medical or Biotechnology Users

Page 3: FOR LEASE PREMIER OFFICE & TECHNOLOGY PARK 4050 PREMIER … · 2018. 8. 3. · 4050 PREMIER DRIVE HIGH POINT, NC 27265 PROPERTY OVERVIEW Premier Office & Technology Park is an office

Part of the CBRE affiliate networkPart of the CBRE affiliate network

www.cbre.us/triad

4050 PREMIER DRIVE HIGH POINT, NORTH CAROLINA

2700

Eas

t Car

y Stre

et

Ri

chmo

nd, V

A 23

223

T

. 804

.287.8

200

F

. 804

.287.8

279

w

ww.od

ell.co

m

AUGUST 30, 2017

ELEVATOR LOBBY 14050 PREMIER DRIVE4050 PREMIER DRIVE HIGH POINT, NC 27265

2017 ODELL Associates, Inc., All Rights Reservedc

3

MAJOR RENOVATIONS + New marquee monument sign to be installed at corner of Premier Dr and Highway 68 (33,000+ vehicles per day) + New entrance to building provides direct access to improved building lobby + Shell space allowing for quick upfit to tenant specifications

NEW ELEVATOR LOBBYNEW MAIN ENTRANCE

NEW MONUMENT SIGN AT INTERSECTION OF EASTCHESTER DR/HIGHWAY 68 AND PREMIER DR

© 2018 CB Richard Ellis-Raleigh LLC, a Delaware limited liability company. This information has been obtained from sources believed reliable. We have not verified it and make no guarantee, warranty or representation about it. Any projections, opinions, assumptions or estimates used are for example only and do not represent the current or future performance of the property. You and your advisors should conduct a careful, independent investigation of the property to determine to your satisfaction the suitability of the property for your needs. CBRE and the CBRE logo are service marks of CBRE, Inc. and/or its affiliated or related companies in the United States and other countries. All other marks displayed on this document are the property of their respective owners. Photos herein are the property of their respective owners and use of these images without the express written consent of the owner is prohibited.

FOR LEASE

FOR LEASE

E

AST

CH

ESTE

R D

R/H

WY

68 PREMIER DR