for steel panels - dimensional metals, inc.dynaclad ap synthetic underlayment dynaclad ap synthetic...

30
PANEL EXPANSION NOTE FOR STEEL PANELS < 40' WITH A 1 1/2" TURN DOWN AND 1 1/2" HEM CLEARANCE: 1. 1/4" FOR INSTALLATION TEMPERATURE BELOW 30 DEGREES FARENHEIT 2. 1/2" FOR INSTALLATION TEMPERATURE ABOVE 30 DEGREES FARENHEIT.. FOR STEEL PANELS > 40' WITH A 2" TURN DOWN AND 2" HEM CLEARANCE: 1. 1/4" FOR INSTALLATION TEMPERATURE BELOW 30 DEGREES FARENHEIT. 2. 1/2" FOR INSTALLATION TEMPERATURE ABOVE 30 DEGREES FARENHEIT. FOR ALUMINUM PANELS - CONTACT DMI GUTTER LAP NOTE LAP GUTTER 3" MIN W/ 2 ROWS OF APPROVED SEALANT AND POP RIVET JOINT 2" O.C. SET IN AND CAP POP RIVETS IN APPROVED SEALANT. FLASHING LAP NOTE LAP FLASHINGS 2" MIN W/ 1 ROW OF BUTYL SEALANT. ICE AND WATER UNDERLAYMENT NOTE FULL ICE AND WATER UNDERLAYMENT REQUIRED. STRIP IN DRIP EDGE WITH 6" OF APPROVED ICE AND WATER UNDERLAYMENT. 12" FROM END OF PANEL (GU) - DMI CONTINUOUS GUTTER (GS) - DMI CONTINUOUS GUTTER STRAP 30" O.C. MAX. DMI DL15 EXPANSION PANEL CLIP 30" O.C. MAX (FASTENED WITH 2 #14-13 X 1 1/2" MIN. DP1 FASTENERS PENETRATING WOOD DECK 3/4" MIN) DL15 DMI PANEL SYSTEM (DE) - DRIP EDGE FIELD FOLD END OF PANEL FILL PANEL VOID AS NECESSARY WITH APPROVED SEALANT INJECT TWO ROWS OF BUTYL SEALANT IN VERTICAL LEG (DS) - DOWNSPOUT (DR) - DROP POP RIVET (EIGHT PER OUTLET) AND SEAL WITH NOVA FLEX OR EQUAL PLYWOOD SHEATHING (MIN. 5/8" THICK) #10-13 GP PANCAKE HEAD FASTENER 6" O.C. (STAGGERED) #10-13 GP PANCAKE HEAD FASTENER 12" O.C. #14-13 DP1 FASTENER 30" O.C. WOOD BLOCKING (FW) - FASCIA WRAP DYNACLAD ULTRA HT WIND & WATER SEAL UNDERLAYMENT TO EXTEND DOWN EAVE 4” MIN. AND OVER THE TOP OF THE FASCIA WRAP AND NAILED INTO FASCIA 6” O.C. DYNACLAD AP SYNTHETIC UNDERLAYMENT 01/17 3"=1'-0" DIMENSIONAL METALS, INC. PROVEN DEPENDABLE SUSTAINABLE METAL ENVELOPE SYSTEMS SINCE 1988 WWW.DMIMETALS.COM Issue/Rev Date: Scale: Detail: ARCHITECTURAL EAVE W/ GUTTER DL15 01-00-WA

Upload: others

Post on 14-Mar-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

PANEL EXPANSION NOTEFOR STEEL PANELS < 40' WITH A 1 1/2" TURN DOWN AND 1 1/2" HEM CLEARANCE:1. 1/4" FOR INSTALLATION TEMPERATURE BELOW 30 DEGREES FARENHEIT2. 1/2" FOR INSTALLATION TEMPERATURE ABOVE 30 DEGREES FARENHEIT..

FOR STEEL PANELS > 40' WITH A 2" TURN DOWN AND 2" HEM CLEARANCE:1. 1/4" FOR INSTALLATION TEMPERATURE BELOW 30 DEGREES FARENHEIT.2. 1/2" FOR INSTALLATION TEMPERATURE ABOVE 30 DEGREES FARENHEIT.

FOR ALUMINUM PANELS - CONTACT DMI

GUTTER LAP NOTELAP GUTTER 3" MIN W/ 2 ROWS OF APPROVED SEALANT AND POP RIVET JOINT 2" O.C. SET IN AND CAP POPRIVETS IN APPROVED SEALANT.

FLASHING LAP NOTELAP FLASHINGS 2" MIN W/ 1 ROW OF BUTYL SEALANT.

ICE AND WATER UNDERLAYMENT NOTEFULL ICE AND WATER UNDERLAYMENT REQUIRED. STRIP IN DRIP EDGE WITH 6" OF APPROVED ICE ANDWATER UNDERLAYMENT.

12" FROM END OF P

ANEL

(GU) - DMI CONTINUOUS GUTTER

(GS) - DMI CONTINUOUSGUTTER STRAP 30" O.C. MAX.

DMI DL15 EXPANSION PANEL CLIP 30" O.C. MAX(FASTENED WITH 2 #14-13 X 1 1/2" MIN. DP1

FASTENERS PENETRATING WOOD DECK 3/4" MIN)

DL15 DMI PANEL SYSTEM

(DE) - DRIP EDGEFIELD FOLD END OF PANEL

FILL PANEL VOID AS NECESSARYWITH APPROVED SEALANT

INJECT TWO ROWS OF BUTYLSEALANT IN VERTICAL LEG

(DS) - DOWNSPOUT

(DR) - DROP

POP RIVET (EIGHT PEROUTLET) AND SEAL WITH

NOVA FLEX OR EQUAL

PLYWOOD SHEATHING (MIN.5/8" THICK)

#10-13 GP PANCAKE HEADFASTENER 6" O.C. (STAGGERED)#10-13 GP PANCAKEHEAD FASTENER 12" O.C.

#14-13 DP1 FASTENER 30" O.C.

WOOD BLOCKING

(FW) - FASCIA WRAP

DYNACLAD ULTRA HT WIND & WATER SEALUNDERLAYMENT TO EXTEND DOWN

EAVE 4” MIN. AND OVER THE TOP OF THEFASCIA WRAP AND NAILED INTO FASCIA 6” O.C.

DYNACLAD AP SYNTHETICUNDERLAYMENT

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL EAVE W/ GUTTER DL15 01-00-WA

Page 2: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

PANEL EXPANSION NOTEFOR STEEL PANELS < 40' WITH A 1 1/2" TURN DOWN AND 1 1/2" HEM CLEARANCE:1. 1/4" FOR INSTALLATION TEMPERATURE BELOW 30 DEGREES FARENHEIT2. 1/2" FOR INSTALLATION TEMPERATURE ABOVE 30 DEGREES FARENHEIT..

FOR STEEL PANELS > 40' WITH A 2" TURN DOWN AND 2" HEM CLEARANCE:1. 1/4" FOR INSTALLATION TEMPERATURE BELOW 30 DEGREES FARENHEIT.2. 1/2" FOR INSTALLATION TEMPERATURE ABOVE 30 DEGREES FARENHEIT.

FOR ALUMINUM PANELS - CONTACT DMI

FLASHING LAP NOTELAP FLASHINGS 2" MIN W/ 1 ROW OF BUTYL SEALANT.

ICE AND WATER UNDERLAYMENT NOTEFULL ICE AND WATER UNDERLAYMENT REQUIRED. STRIP IN DRIP EDGE WITH 6" OF APPROVED ICE AND WATERUNDERLAYMENT.

12" FROM END OF P

ANEL

DMI DL15 EXPANSION PANEL CLIP 30" O.C. MAX(FASTENED WITH 2 #14-13 X 1 1/2" MIN. DP1

FASTENERS PENETRATING WOOD DECK 3/4" MIN)

DL15 DMI PANEL SYSTEM

(DE) - DRIP EDGEFIELD FOLD END OF PANEL

FILL PANEL VOID AS NECESSARYWITH APPROVED SEALANT

INJECT TWO ROWS OF BUTYLSEALANT IN VERTICAL LEG

#10-13 GP PANCAKEHEAD FASTENER 12" O.C.

PLYWOOD SHEATHING (MIN.5/8" THICK)

DYNACLAD ULTRA HT WIND & WATER SEALUNDERLAYMENT TO EXTEND DOWN

EAVE 4” MIN. AND OVER THE TOP OF THEFASCIA WRAP AND NAILED INTO FASCIA 6” O.C.

WOOD BLOCKING(FW) - FASCIA WRAP

#10-13 GP PANCAKE HEADFASTENER 6" O.C. (STAGGERED)

DYNACLAD AP SYNTHETICUNDERLAYMENT

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL EAVE W/ FASCIA WRAP DL15 01-01-WA

Page 3: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

PANEL EXPANSION NOTEFOR STEEL PANELS < 40' WITH A 1 1/2" TURN DOWN AND 1 1/2" HEM CLEARANCE:1. 1/4" FOR INSTALLATION TEMPERATURE BELOW 30 DEGREES FARENHEIT2. 1/2" FOR INSTALLATION TEMPERATURE ABOVE 30 DEGREES FARENHEIT..

FOR STEEL PANELS > 40' WITH A 2" TURN DOWN AND 2" HEM CLEARANCE:1. 1/4" FOR INSTALLATION TEMPERATURE BELOW 30 DEGREES FARENHEIT.

2. 1/2" FOR INSTALLATION TEMPERATURE ABOVE 30 DEGREES FARENHEIT.

FOR ALUMINUM PANELS - CONTACT DMI

GUTTER NOTESLAP GUTTER 3" MIN W/ 2 ROWS OF APPROVED SEALANT AND POP RIVET JOINT 2" O.C. SET IN AND CAP POPRIVETS IN APPROVED SEALANT.EXPANSION JOINT REQUIRED FOR EVERY 50'-0" OF GUTTER (REFER TO MISCELLANEOUS DETAILS)

FLASHING LAP NOTELAP FLASHINGS 2" MIN W/ 1 ROW OF BUTYL SEALANT.

ICE AND WATER UNDERLAYMENT NOTEFULL ICE AND WATER UNDERLAYMENT REQUIRED. STRIP IN DRIP EDGE WITH 6" OF APPROVED ICE ANDWATER UNDERLAYMENT.

12" FROM END OF P

ANEL

DL15 DMI PANEL SYSTEM

#10-13 GP PANCAKE HEADFASTENER 6" O.C. (STAGGERED)

#14-13 DP1 FASTENER 30" O.C.

PLYWOOD SHEATHING

PLYWOOD SHEATHING (MIN.5/8" THICK)

#10-13 GP PANCAKEHEAD FASTENER 12" O.C.

(DE) - DRIP EDGEFIELD FOLD END OF PANEL

FILL PANEL VOID AS NECESSARYWITH APPROVED SEALANT

INJECT TWO ROWS OF BUTYLSEALANT IN VERTICAL LEG

DYNACLAD ULTRA HT WIND & WATERSEAL UNDERLAYMENT TO EXTEND

DOWN EAVE 4” MIN. AND OVER THETOP OF THE FASCIA WRAP AND

NAILED INTO FASCIA 6” O.C.

(SI) - SILLFASCIA PANEL

(GU) - DMI CONTINUOUS GUTTER

(GS) - DMI CONTINUOUSGUTTER STRAP 30" O.C. MAX.

(DS) - DOWNSPOUT(DR) - DROP

(SI) - SILL#10-13 GP PANCAKEHEAD FASTENER 12" O.C.

DMI DL15 EXPANSION PANEL CLIP 30" O.C. MAX(FASTENED WITH 2 #14-13 X 1 1/2" MIN. DP1

FASTENERS PENETRATING WOOD DECK 3/4" MIN)

POP RIVET (EIGHT PEROUTLET) AND SEAL WITH

NOVA FLEX OR EQUAL

DYNACLAD AP SYNTHETICUNDERLAYMENT

DYNACLAD AP SYNTHETICUNDERLAYMENT (EXTEND UNDERUPPER SILL AND OVER LOWER SILL)

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL EAVE W/ GUTTER DL15 01-02-WA

Page 4: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

PANEL EXPANSION NOTEFOR STEEL PANELS < 40' WITH A 1 1/2" TURN DOWN AND 1 1/2" HEMCLEARANCE:1. 1/4" FOR INSTALLATION TEMPERATURE BELOW 30 DEGREES FARENHEIT2. 1/2" FOR INSTALLATION TEMPERATURE ABOVE 30 DEGREES FARENHEIT..

FOR STEEL PANELS > 40' WITH A 2" TURN DOWN AND 2" HEMCLEARANCE:1. 1/4" FOR INSTALLATION TEMPERATURE BELOW 30 DEGREES FARENHEIT.2. 1/2" FOR INSTALLATION TEMPERATURE ABOVE 30 DEGREES FARENHEIT.

FOR ALUMINUM PANELS - CONTACT DMI

FLASHING LAP NOTELAP FLASHINGS 2" MIN W/ 1 ROW OF BUTYL SEALANT.

ICE AND WATER UNDERLAYMENT NOTEFULL ICE AND WATER UNDERLAYMENT REQUIRED. STRIP IN DRIP EDGE WITH 6" OFAPPROVED ICE AND WATER UNDERLAYMENT.

12" FROM END OF P

ANEL

DMI DL15 EXPANSION PANEL CLIP 30" O.C. MAX(FASTENED WITH 2 #14-13 X 1 1/2" MIN. DP1

FASTENERS PENETRATING WOOD DECK 3/4" MIN)DL15 DMI PANEL SYSTEM

(DE) - DRIP EDGEFIELD FOLD END OF PANEL

FILL PANEL VOID AS NECESSARYWITH APPROVED SEALANT

INJECT TWO ROWS OF BUTYLSEALANT IN VERTICAL LEG

#10-13 GP PANCAKE HEADFASTENER 6" O.C. (STAGGERED)

PLYWOOD SHEATHING (MIN.5/8" THICK)

(JC) - J CLOSURE

#10-13 GP PANCAKEHEAD FASTENER 12" O.C.

#10-13 GP PANCAKEHEAD FASTENER 12" O.C.

PLYWOOD SHEATHING

(SI) - SILL

FASCIA PANEL

DYNACLAD ULTRA HT WIND & WATERSEAL UNDERLAYMENT TO EXTEND

DOWN EAVE 4” MIN. OVER SILL ANDNAILED DOWN 6” O.C.

DYNACLAD AP SYNTHETICUNDERLAYMENT

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL EAVE W/ FASCIA PANEL DL15 01-03-WA

Page 5: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

(CF) - CAP FLASHING

BUTYL SEALANT(APPLY LIBERALLY)

(CL) - CLEAT#10-13 GP PANCAKE

HEAD FASTENER 12" O.C.

(CL) - CLEAT

E.I.F.S.

PANEL EXPANSION NOTEFOR STEEL PANELS < 40' WITH A 1 1/2" TURN DOWN AND 1 1/2" HEM CLEARANCE:1. 1/4" FOR INSTALLATION TEMPERATURE BELOW 30 DEGREES FARENHEIT

2. 1/2" FOR INSTALLATION TEMPERATURE ABOVE 30 DEGREES FARENHEIT..

FOR STEEL PANELS > 40' WITH A 2" TURN DOWN AND 2" HEM CLEARANCE:1. 1/4" FOR INSTALLATION TEMPERATURE BELOW 30 DEGREES FARENHEIT.2. 1/2" FOR INSTALLATION TEMPERATURE ABOVE 30 DEGREES FARENHEIT.

FOR ALUMINUM PANELS - CONTACT DMI

INTERIOR GUTTER DESIGN TO BE PER SMACNA GUIDELINES

FLASHING LAP NOTELAP FLASHINGS 2" MIN W/ 1 ROW OF BUTYL SEALANT.

ICE AND WATER UNDERLAYMENT NOTEFULL ICE AND WATER UNDERLAYMENT REQUIRED. STRIP IN DRIP EDGE WITH 6" OF APPROVED ICE AND WATERUNDERLAYMENT.

12" FROM END OF P

ANEL

DL15 DMI PANEL SYSTEM

(DE) - DRIP EDGEFIELD FOLD END OF PANEL

FILL PANEL VOID AS NECESSARYWITH APPROVED SEALANT

INJECT TWO ROWS OF BUTYLSEALANT IN VERTICAL LEG

#10-13 GP PANCAKE HEADFASTENER 6" O.C. (STAGGERED)

DMI DL15 EXPANSION PANEL CLIP 30" O.C. MAX(FASTENED WITH 2 #14-13 X 1 1/2" MIN. DP1

FASTENERS PENETRATING WOOD DECK 3/4" MIN)

PLYWOOD SHEATHING (MIN.5/8" THICK)

PLYWOOD SHEATHING

WOOD BLOCKING

60 MIL EPDM EXTEND UP ROOF 24" MIN.AND DOWN FASCIA 4" MIN.

DYNACLAD AP SYNTHETICUNDERLAYMENT

BUTYL SEALANT

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL EAVE W/ BUILT IN GUTTER DL15 01-04-WA

Page 6: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

12" MAXIMUM

EXPANSION NOTERIDGES EXCEEDING 100'-0" IN LENGTH REQUIRE THE USE OF A 6" COVER PLATE.

FLASHING LAP NOTELAP RIDGE/HIP 4" MIN W/ 2 ROWS OF BUTYL SEALANT.DO NOT POP RIVET LAPPED FLASHINGS.

PLYWOOD SHEATHING (MIN.5/8" THICK)

DL15 DMI PANEL SYSTEM

BOX END OF PANEL AND INJECTAPPROVED SEALANT IN CORNERS

(RI / HI) - RIDGE / HIP

TWO CONTINUOUSROWS OF BUTYL TAPE

FOUR #10-13 X 1" GP PANCAKEHEAD FASTENERS PER PANEL MIN.

INJECT APPROVED SEALANTBETWEEN PANEL LEG AND Z CLOSURE

(ZC) - ZEE CLOSURE (SEE SHEETFOR INSTALLATION INSTRUCTIONS)

POP RIVET 8" O.C.

DYNACLAD AP SYNTHETICUNDERLAYMENT

DMI DL15 EXPANSION PANEL CLIP30" O.C. MAX (FASTENED WITH 2#14-13 X 1 1/2" MIN. DP1 FASTENERSPENETRATING WOOD DECK 3/4" MIN)

1/4" WOOD FILLER

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL RIDGE DL15 02-00-WA

Page 7: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

12" MAXIMUM

EXPANSION NOTERIDGES EXCEEDING 100'-0" IN LENGTH REQUIRE THE USE OF A 6" COVER PLATE.

FLASHING LAP NOTELAP RIDGE/HIP 4" MIN W/ 2 ROWS OF BUTYL SEALANT.DO NOT POP RIVET LAPPED FLASHINGS.

VENTILATION NOTEDMI PERFORATED Z CLOSURE PROVIDES 23% NET FREE AIR MOVEMENT.HIP CONDITIONS CAN NOT BE VENTED.

1"

1"

PLYWOOD SHEATHING (MIN.5/8" THICK)

DL15 DMI PANEL SYSTEM

DMI DL15 EXPANSION PANEL CLIP30" O.C. MAX (FASTENED WITH 2#14-13 X 1 1/2" MIN. DP1 FASTENERSPENETRATING WOOD DECK 3/4" MIN)

DYNACLAD AP SYNTHETICUNDERLAYMENT

OPTIONAL VENTING FABRIC (PZC) - PERFORATEDZEE CLOSURE

8-15 X 9/16" LATHHEAD SCREW 12" O.C.

BOX END OF PANEL AND INJECTAPPROVED SEALANT IN CORNERS

(VRI) - VENTED RIDGE

POP RIVET 8" O.C.

TWO CONTINUOUSROWS OF BUTYL TAPE

FOUR #10-13 X 1" GP PANCAKEHEAD FASTENERS PER PANEL MIN.

(ZC) - ZEE CLOSURE (SEE SHEETFOR INSTALLATION INSTRUCTIONS)

INJECT APPROVEDSEALANT BETWEEN PANEL

LEG AND Z CLOSURE

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL VENTED RIDGE DL15 02-01-WA

AutoCAD SHX Text
2"
Page 8: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

2" CAP OVERLAP

EXPANSION NOTERIDGES EXCEEDING 100'-0" IN LENGTH REQUIRE THE USE OF A 6" COVER PLATE.

FLASHING LAP NOTELAP RIDGE/HIP 4" MIN W/ 2 ROWS OF BUTYL SEALANT.DO NOT POP RIVET LAPPED FLASHINGS.

6" COVER PLATE

2 ROWS OF BUTYL SEALANT EACH SIDE

TONG HEMS AROUND CAPS

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL RIDGE COVER PLATE DL15 02-02-WA

Page 9: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

PANEL EXPANSION NOTEFOR STEEL PANELS < 40' WITH A 1 1/2" TURN DOWN AND 1 1/2" HEM CLEARANCE:1. 1/4" FOR INSTALLATION TEMPERATURE BELOW 30 DEGREES FARENHEIT2. 1/2" FOR INSTALLATION TEMPERATURE ABOVE 30 DEGREES FARENHEIT..

FOR STEEL PANELS > 40' WITH A 2" TURN DOWN AND 2" HEM CLEARANCE:1. 1/4" FOR INSTALLATION TEMPERATURE BELOW 30 DEGREES FARENHEIT.

2. 1/2" FOR INSTALLATION TEMPERATURE ABOVE 30 DEGREES FARENHEIT.

PANELS EXCEEDING 40' ADD 1" PER 10' TO EACH SIDE.FOR ALUMINUM PANELS - CONTACT DMINOP POP RIVETS OR FASTENERS ON EXPOSED WEATHER SIDE OF CLEAT.

INVERTED V NOTEON ROOF PITCHES OVER 6:12 OR PANEL LENGTHS EXCEEDING 60' OR ON DISSIMILAR PITCHES INCREASE THEINVERTED V IN THE VALLEY TO 2".

FLASHING LAP NOTELAP VALLEY 8" MIN. WITH 2 ROWS OF APPROVED SEALANT.

12" FROM END OF PANEL

6" MIN.6" MIN. LAP

(VA) - VALLEY(CL) - CLEAT

DYNACLAD AP SYNTHETICUNDERLAYMENT

FIELD FOLD END OF PANEL

INJECT TWO ROWS OF APPROVEDSEALANT IN VERTICAL LEG

DMI DL15 EXPANSION PANEL CLIP30" O.C. MAX (FASTENED WITH 2#14-13 X 1 1/2" MIN. DP1 FASTENERSPENETRATING WOOD DECK 3/4" MIN)

DL15 DMI PANEL SYSTEM

DYNACLAD ULTRA HT WIND &WATER SEAL UNDERLAYMENT

TWO CONTINUOUSROWS OF BUTYL TAPE

#10-13 GP PANCAKEHEAD FASTENERS 3" O.C.

INVERTED V 1" MIN.(SEE NOTE ABOVE)

PLYWOOD SHEATHING (MIN.5/8" THICK)

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL VALLEY DL15 03-00-WA

Page 10: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

FLASHING LAP NOTELAP RAKE EDGE AND FASCIA 2" MINIMUM WITH 1 ROW OF BUTYL SEALANT.

FIELD FOLD SIDE OF PANEL

DL15 DMI PANEL SYSTEM

(RE) - RAKE EDGE

(FW) - FASCIA WRAP

PLYWOOD SHEATHING (MIN.5/8" THICK)

#10-13 GP PANCAKEHEAD FASTENER 12" O.C.

WOOD BLOCKING

DYNACLAD AP SYNTHETICUNDERLAYMENT

#10-13 GP PANCAKEHEAD FASTENER 12" O.C.

DYNACLAD ULTRA HT WIND & WATERSEAL UNDERLAYMENT TO EXTEND

DOWN RAKE EDGE 4” MIN. AND OVERTHE TOP OF THE FASCIA WRAP AND

NAILED INTO FASCIA 6” O.C.

1/4" WOOD FILLER

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL RAKE EDGE DL15 04-00-WA

Page 11: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

FLASHING LAP NOTELAP RAKE EDGE AND FASCIA 2" MINIMUM WITH 2 ROWS OF BUTYL SEALANT.

PLYWOOD SHEATHING (MIN.5/8" THICK)

#10-13 GP PANCAKE HEAD FASTENER.SEAL HEADS WITH BUTYL SEALANT.

DYNACLAD AP SYNTHETICUNDERLAYMENTDYNACLAD ULTRA HT WIND & WATER

SEAL UNDERLAYMENT TO EXTENDDOWN RAKE EDGE 4” MIN. AND OVERTHE TOP OF THE FASCIA WRAP AND

NAILED INTO FASCIA 6” O.C.

(JC) - J CLOSURE

(RA) - RAKE EDGE

(FW) - FASCIA WRAP

WOOD BLOCKING

ONE CONTINUOUSROW OF BUTYL TAPE

POP RIVET 12" O.C. DONOT PENETRATE PANEL LEG

#10-13 GP PANCAKEHEAD FASTENER 12" O.C.

(CL) - CLEAT

DL15 DMI PANEL SYSTEM

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL RAKE EDGE DL15 04-01-WA

Page 12: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

#10-13 GP PANCAKEHEAD FASTENER 12" O.C.

(FW) - FASCIA WRAP

DL15 DMI PANEL SYSTEM

WOOD BLOCKING

WOOD BLOCKING

FULL DYNACLAD ULTRA HTWIND & WATER SEAL UNDERLAYMENT

TO EXTEND DOWN RAKEEDGE 4” MIN. AND OVER THE TOP OFTHE FASCIA WRAP AND NAILED INTO

FASCIA 6” O.C.

ONE CONTINUOUS ROW OFBUTYL TAPE ON BOTH SIDES

1/4-14 X 7/8" DP1 LAP ZAC ZINCCAP W/ EPDM WASHER @ 12" O.C.

(RA) - ANGLE

(SRA) - RAKE ANGLEW/SLOTTED HOLES IN

BOTTOM LEG TO ALLOWTHERMAL MOVEMENT

ONE CONTINUOUS ROW OFBUTYL TAPE ON BOTH SIDES

(RE) - RAKE EDGE

(CL) - CLEAT

SHOULDER BOLT 24" O.C.

PLYWOOD SHEATHING (MIN.5/8" THICK)

FLASHING LAP NOTELAP RAKE EDGE AND FASCIA 2" MINIMUM WITH 2 ROWS OF BUTYL SEALANT.

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL RAKE EDGE DL15 04-02-WA

Page 13: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

NOTEREGLET FLASHING TO BE INSTALLED BELOW ALL WEEP HOLES.SURFACED MOUNT COUNTERFLASHINGS NOT ACCEPTABLE..

FLASHING LAP NOTELAP (RW) - RAKE WALL REGLET 2" MINIMUM WITH 2 ROWS OF BUTYL SEALANT.

6"8"

DL15 DMI PANEL SYSTEM

POP RIVET 12" O.C.

MASONRY

WEDGE SPACED 12" O.C.CONTINUOUS NOVA FLEX SEALANT

(RC) - REGLET COUNTERFLASHING(RW) - RAKE WALL

MASONRY WEEP THROUGHWALL FLASHING

STAINLESS STEEL CAVITYWALL FLASHING

ONE CONTINUOUSROW OF BUTYL TAPE

DYNACLAD AP SYNTHETICUNDERLAYMENT

DYNACLAD ULTRA HT WIND &WATER SEAL UNDERLAYMENT

(EXTEND UP WALL 8" MIN.)

PLYWOOD SHEATHING (MIN.5/8" THICK)

1/4" WOOD FILLER

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL RAKE WALL DL15 05-00-WA

Page 14: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

FLASHING LAP NOTELAP (RW) - RAKE WALL AND RAT GUARD (SLOPED) 2" MINIMUM WITH 2 ROWS OF BUTYL SEALANT.

6"

2"

8"

#10-13 GP PANCAKEHEAD FASTENER 12" O.C.

WALL PANEL

(RG) - RAT GUARD (SLOPED)

DL15 DMI PANEL SYSTEM

POP RIVET 12" O.C.

ONE CONTINUOUSROW OF BUTYL TAPE

(RW) - CURVED (RW) - RAKE WALL

APPROVED MOISTURE BARRIER

DYNACLAD AP SYNTHETICUNDERLAYMENT

DYNACLAD ULTRA HT WIND &WATER SEAL UNDERLAYMENT

(EXTEND UP WALL 8" MIN.)

PLYWOOD SHEATHING (MIN.5/8" THICK)

1/4" WOOD FILLER

PLYWOOD SHEATHING

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL RAKE WALL DL15 05-01-WA

Page 15: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

FLASHING LAP NOTELAP RAKE WALL AND RAT GUARD (SLOPED) 2" MINIMUM WITH 2 ROWS OF BUTYL SEALANT.

2"8"

#10-13 GP PANCAKEHEAD FASTENER 12" O.C.

POP RIVET 12" O.C. DO NOTPENETRATE PANEL LEG

(JC) - J CLOSURE

#10-13 GP PANCAKE HEADFASTENER 12" O.C. SET IN AND

CAP WITH APPROVED SEALANTPLYWOOD SHEATHING

WALL PANEL

(RG) - RAT GUARD (SLOPED)

(RW) - RAKE WALL

DYNACLAD AP SYNTHETICUNDERLAYMENT

DYNACLAD ULTRA HT WIND &WATER SEAL UNDERLAYMENT

(EXTEND UP WALL 8" MIN.)

DL15 DMI PANEL SYSTEM

ONE CONTINUOUSROW OF BUTYL TAPE

PLYWOOD SHEATHING (MIN.5/8" THICK)

APPROVED MOISTURE BARRIER

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL RAKE WALL DL15 05-02-WA

Page 16: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

NOTE: INTEGRATE COUNTER FLASHINGINTO NEW MASONRY THRU WALL FLASHING

NOVA FLEX CONTINUOUS SEALANT

(RC) - REGLET COUNTERFLASHING

(RW) - RAKE WALL

1/4-14 X 7/8" DP1 LAP ZAC ZINCCAP W/ EPDM WASHER @ 8" O.C.

SHOULDER BOLT 24" O.C.

FULL DYNACLAD ULTRA HT WINDAND WATER SEAL UNDERLAYMENT

TO EXTEND UP WALL 8"

MASONRY

ONE CONTINUOUSROW OF BUTYL TAPE

(SRA) - RAKE ANGLEW/SLOTTED HOLES INBOTTOM LEG TO ALLOWTHERMAL MOVEMENT

(RA) - ANGLE

3/16" SAWCUT REGLET

WEDGE SPACED 6" O.C.

PLYWOOD SHEATHING (MIN.5/8" THICK)

DL15 DMI PANEL SYSTEM

NOTEREGLET FLASHING TO BE INSTALLED BELOW ALL WEEP HOLES.

SURFACED MOUNT COUNTERFLASHINGS NOT ACCEPTABLE..

FLASHING LAP NOTELAP (RW) - RAKE WALL REGLET 2" MINIMUM WITH 2 ROWS OF BUTYL SEALANT.

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL RAKE WALL DL15 05-03-WA

Page 17: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

FLASHING LAP NOTELAP APRON AND RAT GUARD (SLOPED) 2" MINIMUM WITH 2 ROWS OF BUTYL SEALANT.

12" MAXIMUM

3" M

IN.

DMI DL15 EXPANSION PANEL CLIP30" O.C. MAX (FASTENED WITH 2

#14-13 X 1 1/2" MIN. DP1 FASTENERSPENETRATING WOOD DECK 3/4" MIN)

DL15 DMI PANEL SYSTEM

FOUR #10-13 GP PANCAKE HEADFASTENERS PER PANEL MIN.

POP RIVET 8" O.C.

DYNACLAD AP SYNTHETIC UNDERLAYMENTTO EXTEND UP WALL 8"

(AP) - APRON

WALL PANEL

(RG) - RAT GUARD

BOX END OF PANEL AND INJECTAPPROVED SEALANT IN CORNERS

INJECT APPROVED SEALANTBETWEEN PANEL AND Z CLOSURE

(ZC) - ZEE CLOSURE (SEE SHEETFOR INSTALLATION INSTRUCTIONS)

TWO CONTINUOUSROWS OF BUTYL TAPE

#10-13 GP PANCAKE HEADFASTENERS 12" O.C.

1/4" WOOD FILLER

APPROVED MOISTURE BARRIER

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL APRON W/ WALL PANEL DL15 06-00-WA

Page 18: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

NOTEREGLET FLASHING TO BE INSTALLED BELOW ALL WEEP HOLES.

SURFACED MOUNT COUNTERFLASHINGS NOT ACCEPTABLE..

FLASHING LAP NOTELAP APRON AND REGLET 2" MINIMUM WITH 2 ROWS OF BUTYL SEALANT.

12" MAXIMUM3"

MIN

.

DMI DL15 EXPANSION PANEL CLIP30" O.C. MAX (FASTENED WITH 2

#14-13 X 1 1/2" MIN. DP1 FASTENERSPENETRATING WOOD DECK 3/4" MIN)

DL15 DMI PANEL SYSTEM

FOUR #10-13 GP PANCAKE HEADFASTENERS PER PANEL MIN.

DYNACLAD AP SYNTHETIC UNDERLAYMENTTO EXTEND UP WALL 8"

(AP) - APRON

WEDGE SPACED 12" O.C.

(RC) - REGLET COUNTERFLASHING

MASONRY WEEP THROUGHWALL FLASHING

STAINLESS STEEL CAVITYWALL FLASHING

MASONRY

MASONRY FASTENER@ 12" O.C.

PLYWOOD SHEATHING (MIN.5/8" THICK)

BOX END OF PANEL AND INJECTAPPROVED SEALANT IN CORNERS

(ZC) - ZEE CLOSURE (SEE SHEETFOR INSTALLATION INSTRUCTIONS)

INJECT APPROVED SEALANTBETWEEN PANEL AND Z CLOSURE

TWO CONTINUOUSROWS OF BUTYL TAPE

CONTINUOUS NOVA FLEX SEALANT

1/4" WOOD FILLER

POP RIVET 8" O.C.

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL APRON DL15 06-01-WA

Page 19: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

1"1"

1"

FLASHING LAP NOTELAP APRON AND RAT GUARD (SLOPED) 2" MIN W/ 2 ROWS OF BUTYL SEALANT.DO NOT POP RIVET LAPPED FLASHINGS.

VENTILATION NOTEDMI PERFORATED Z CLOSURE PROVIDES 23% NET FREE AIR MOVEMENT.

12" MAXIMUM3"

MIN

.

DMI DL15 EXPANSION PANEL CLIP30" O.C. MAX (FASTENED WITH 2

#14-13 X 1 1/2" MIN. DP1 FASTENERSPENETRATING WOOD DECK 3/4" MIN)

DL15 DMI PANEL SYSTEM

#10-13 GP PANCAKE HEADFASTENERS 12" O.C.

DYNACLAD AP SYNTHETICUNDERLAYMENT

OPTIONAL VENTING FABRIC(PZC) - PERFORATED Z CLOSURE

8-15 X 9/16" LATH HEAD SCREW 12" O.C.

(AP) - APRON

APPROVED MOISTURE BARRIERWALL PANEL

(RG) - RAT GUARD

BOX END OF PANEL AND INJECTAPPROVED SEALANT IN CORNERS

(ZC) - ZEE CLOSURE (SEE SHEET FORINSTALLATION INSTRUCTIONS)

TWO CONTINUOUSROWS OF BUTYL TAPE

FOUR #10-13 GP PANCAKE HEADFASTENERS PER PANEL MIN.

POP RIVET 8" O.C.

INJECT APPROVED SEALANTBETWEEN PANEL AND Z CLOSURE

PLYWOOD SHEATHING (MIN.5/8" THICK)

1/4" WOOD FILLER

PLYWOOD SHEATHING

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL VENTED APRON DL15 06-02-WA

Page 20: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

1"1"

1"

12" MAXIMUM

NOTEREGLET FLASHING TO BE INSTALLED BELOW ALL WEEP HOLES.SURFACED MOUNT COUNTERFLASHINGS NOT ACCEPTABLE..

FLASHING LAP NOTELAP APRON AND RAT GUARD (SLOPED) 2" MIN W/ 2 ROWS OF BUTYL SEALANT.DO NOT POP RIVET LAPPED FLASHINGS.

VENTILATION NOTEDMI PERFORATED Z CLOSURE PROVIDES 23% NET FREE AIR MOVEMENT.

3" M

IN.

MASONRY FASTENER@ 12" O.C.

DMI DL15 EXPANSION PANELCLIP 30" O.C. MAX (FASTENEDWITH 2 #14-13 X 1 1/2" MIN. DP1

FASTENERS PENETRATINGWOOD DECK 3/4" MIN)

DL15 DMI PANEL SYSTEM

(AP) - APRON

WEDGE SPACED 12" O.C.CONTINUOUS NOVA FLEX SEALANT(RC) - REGLET COUNTERFLASHING

MASONRY WEEPTHROUGH WALL FLASHING

STAINLESS STEELCAVITY WALL FLASHING

DYNACLAD AP SYNTHETICUNDERLAYMENT

OPTIONAL VENTING FABRIC(PZC) - PERFORATED Z CLOSURE

8-15 X 9/16" LATH HEAD SCREW 12" O.C.

BOX END OF PANEL AND INJECTAPPROVED SEALANT IN CORNERS

(ZC) - ZEE CLOSURE (SEE SHEET FORINSTALLATION INSTRUCTIONS)

TWO CONTINUOUSROWS OF BUTYL TAPE

FOUR #10-13 GP PANCAKE HEADFASTENERS PER PANEL MIN.

POP RIVET 8" O.C.

MASONRY

INJECT APPROVED SEALANTBETWEEN PANEL AND Z CLOSURE

PLYWOOD SHEATHING (MIN.5/8" THICK)

1/4" WOOD FILLER

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL VENTED APRON DL15 06-03-WA

Page 21: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

FLASHING LAP NOTELAP APRON AND REGLET 2" MINIMUM WITH 2 ROWS OF BUTYL SEALANT.

12" MAXIMUM

(AP) - APRON

POP RIVET 8" O.C.(ZC) - ZEE CLOSURE (SEE SHEET

FOR INSTALLATION INSTRUCTIONS)DYNACLAD AP SYNTHETIC

UNDERLAYMENT TO EXTEND UP WALL 8"

TWO CONTINUOUSROWS OF BUTYL TAPE

FOUR #10-13 GP PANCAKE HEADFASTENERS PER PANEL MIN.INJECT APPROVED SEALANT

BETWEEN PANEL AND Z CLOSURE

DMI DL15 EXPANSION PANEL CLIP30" O.C. MAX (FASTENED WITH 2

#14-13 X 1 1/2" MIN. DP1 FASTENERSPENETRATING WOOD DECK 3/4" MIN)

DL15 DMI PANEL SYSTEM

PLYWOOD SHEATHING (MIN.5/8" THICK)

BOX END OF PANEL AND INJECTAPPROVED SEALANT IN CORNERS

1/4" WOOD FILLER

3"

1-1/4" SS RING SHANKNAIL 12" O.C.

(CO) - DYNACLAD EDGESNAP-ON COPING

(AC) - ANCHOR CLEAT#9-15 X 1-1/2" SS FASTENER

(4 PER ANCHOR CLEAT)MEMBRANE

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL APRON W/ COPING DL15 06-04-WA

Page 22: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

EXPANSION NOTEPEAK CAPS EXCEEDING 100'-0" IN LENGTH REQUIRE THE USE OF A 6" COVER PLATE.

FLASHING LAP NOTELAP PEAK AND CLEATS 2" MIN W/ 2 ROWS OF BUTYL SEALANT.

DO NOT POP RIVET LAPPED FLASHINGS.

12" MAXIMUM

DMI DL15 EXPANSION PANEL CLIP 30"O.C. MAX (FASTENED WITH 2 #14-13 X

1 1/2" MIN. DP1 FASTENERSPENETRATING WOOD DECK 3/4" MIN)

DL15 DMI PANEL SYSTEM

FOUR #10-13 GP PANCAKE HEADFASTENERS PER PANEL MIN.

POP RIVET 8" O.C.

DYNACLAD AP SYNTHETICUNDERLAYMENT

DOWN FACE 4" MIN.1/4" WOOD FILLER

POP RIVET 12" O.C.

MEMBRANE ROOFING

PLYWOOD SHEATHING (MIN.5/8" THICK)

BOX END OF PANEL AND INJECTAPPROVED SEALANT IN CORNERS

INJECT APPROVED SEALANTBETWEEN PANEL AND Z CLOSURE

(ZC) - ZEE CLOSURE (SEE SHEETFOR INSTALLATION INSTRUCTIONS)

TWO CONTINUOUSROWS OF BUTYL TAPE

(CL) - CLEAT

#10-13 GP PANCAKEHEAD FASTENER 12" O.C.

PLYWOOD SHEATHING

(PC) - PEAK CAP

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL PEAK DL15 07-00-WA

Page 23: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

EXPANSION NOTEPEAK CAPS EXCEEDING 100'-0" IN LENGTH REQUIRE THE USE OF A 6" COVER PLATE.

FLASHING LAP NOTELAP PEAK AND CLEATS 2" MIN W/ 2 ROWS OF BUTYL SEALANT.DO NOT POP RIVET LAPPED FLASHINGS.

12" MAXIMUM

(ZC) - ZEE CLOSURE (SEE SHEETFOR INSTALLATION INSTRUCTIONS)

DMI DL15 EXPANSION PANEL CLIP30" O.C. MAX (FASTENED WITH 2

#14-13 X 1 1/2" MIN. DP1 FASTENERSPENETRATING WOOD DECK 3/4" MIN)

DL15 DMI PANEL SYSTEM

PLYWOOD SHEATHING (5/8"MIN. THICKNESS)

TWO CONTINUOUSROWS OF BUTYL TAPE

FOUR #10-13 GP PANCAKE HEADFASTENERS PER PANEL MIN.

POP RIVET 8" O.C.

DYNACLAD AP SYNTHETICUNDERLAYMENT DOWN FACE 4" MIN.

POP RIVET 12" O.C.

WALL PANEL

(PC) - PEAK CAP

INJECT APPROVED SEALANTBETWEEN PANEL AND Z CLOSURE

#10-13 GP PANCAKEHEAD FASTENER 12" O.C.

PLYWOOD SHEATHING

(JC) - J CLOSURE

BOX END OF PANEL AND INJECTAPPROVED SEALANT IN CORNERS

1/4" WOOD FILLER

APPROVED MOISTURE BARRIER

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL PEAK W/ WALL PANEL DL15 07-01-WA

Page 24: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

1"1"

1"

12" MAXIMUM

DMI DL15 EXPANSION PANELCLIP 30" O.C. MAX (FASTENEDWITH 2 #14-13 X 1 1/2" MIN. DP1

FASTENERS PENETRATINGWOOD DECK 3/4" MIN)DL15 DMI PANEL SYSTEM

DYNACLAD AP SYNTHETICUNDERLAYMENT

OPTIONAL VENTING FABRIC(PZC) - PERFORATED Z CLOSURE

8-15 X 9/16" LATH HEAD SCREW 12" O.C.

BOX END OF PANEL AND INJECTAPPROVED SEALANT IN CORNERS

(ZC) - ZEE CLOSURE (SEE SHEET FORINSTALLATION INSTRUCTIONS)

TWO CONTINUOUSROWS OF BUTYL TAPE

FOUR #10-13 GP PANCAKE HEADFASTENERS PER PANEL MIN.

POP RIVET 8" O.C.

INJECT APPROVED SEALANTBETWEEN PANEL AND Z CLOSURE

PLYWOOD SHEATHING (MIN.5/8" THICK)

1/4" WOOD FILLER

EXPANSION NOTEPEAK CAPS EXCEEDING 100'-0" IN LENGTH REQUIRE THE USE OF A 6" COVER PLATE.

FLASHING LAP NOTELAP PEAK AND CLEATS 2" MIN W/ 2 ROWS OF BUTYL SEALANT.DO NOT POP RIVET LAPPED FLASHINGS.

POP RIVET 12" O.C.

MEMBRANE ROOFING

(CL) - CLEAT

#10-13 GP PANCAKEHEAD FASTENER 12" O.C.

PLYWOOD SHEATHING

(PC) - PEAK CAP

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL VENTED PEAK DL15 07-02-WA

Page 25: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

±

FLASHING LAP NOTELAP EXPANSION JOINT AND J CLOSURE 2" MINIMUM WITH 2 ROWS OF BUTYL SEALANT.

CONTINUOUS FLEXIBLE MEMBRANE -EXTEND 12" MIN. IN EACH DIRECTION.

#10-13 GP PANCAKE HEADFASTENER 12" O.C. SET IN ANDCAP WITH APPROVED SEALANT

WOOD BLOCKING

BUILDING EXPANSION FROM DESIGNDRAWINGS OR FIELD DIMENSIONS

PLYWOOD SHEATHING (MIN.5/8" THICK)

DYNACLAD AP SYNTHETICUNDERLAYMENT

ONE CONTINUOUSROW OF BUTYL TAPE

POP RIVET 12" O.C. DONOT PENETRATE PANEL LEG

(EJ) - EXPANSION JOINT

BATT INSULATION

(JC) - J CLOSURE

DL15 DMI PANEL SYSTEM

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL EXPANSION JOINT DL15 08-00-WA

AutoCAD SHX Text
a
AutoCAD SHX Text
a+1/4"
AutoCAD SHX Text
a-1/4"
AutoCAD SHX Text
2a
Page 26: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

±

NOTEREGLET FLASHING TO BE INSTALLED BELOW ALL WEEP HOLES.SURFACED MOUNT COUNTERFLASHINGS NOT ACCEPTABLE..

FLASHING LAP NOTELAP RAKE WALL AND REGLET 2" MINIMUM WITH 2 ROWS OF BUTYL SEALANT.

BUILDING EXPANSIONFROM DESIGN DRAWINGSOR FIELD DIMENSIONS

PLYWOOD SHEATHING (MIN.5/8" THICK)

#10-13 GP PANCAKE HEADFASTENER 12" O.C. SET IN AND

CAP WITH APPROVED SEALANT BATT INSULATION

(RWEJ) - RAKE WALL EXPANSION JOINT

(JC) - J CLOSURE

DYNACLAD AP SYNTHETICUNDERLAYMENT

DYNACLAD ULTRA HT WIND &WATER SEAL UNDERLAYMENT

DL15 DMI PANEL SYSTEM

MASONRY

WEDGE SPACED 12" O.C.

CONTINUOUS NOVA FLEX SEALANT

(RC) - REGLET COUNTERFLASHING

MASONRY WEEP THROUGHWALL FLASHING

STAINLESS STEEL CAVITYWALL FLASHING

MASONRY FASTENER@ 12" O.C.

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL EXPANSION RAKEWALL DL15 09-00-WA

AutoCAD SHX Text
a
AutoCAD SHX Text
a-1/4"
AutoCAD SHX Text
2a
AutoCAD SHX Text
a+1/4"
Page 27: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

18" MIN.

PANEL EXPANSION NOTEFOR STEEL PANELS < 40' WITH A 1 1/2" TURN DOWN AND 1 1/2" HEM CLEARANCE:1. 1/4" FOR INSTALLATION TEMPERATURE BELOW 30 DEGREES FARENHEIT2. 1/2" FOR INSTALLATION TEMPERATURE ABOVE 30 DEGREES FARENHEIT..

FOR STEEL PANELS > 40' WITH A 2" TURN DOWN AND 2" HEM CLEARANCE:1. 1/4" FOR INSTALLATION TEMPERATURE BELOW 30 DEGREES FARENHEIT.2. 1/2" FOR INSTALLATION TEMPERATURE ABOVE 30 DEGREES FARENHEIT.

FOR ALUMINUM PANELS - CONTACT DMI

FLASHING LAP NOTELAP FLASHINGS 2" MIN W/ 1 ROW OF BUTYL SEALANT.

8" M

IN.

12" FROM END OF PANEL

MEMBRANE ROOFINGEXTENED UP ROOF 36" MIN.

(TF) - TRANSITION FLASHING

FIELD FOLD END OF PANEL

FILL PANEL VOID AS NECESSARYWITH APPROVED SEALANT

INJECT TWO ROWS OF BUTYLSEALANT IN VERTICAL LEG

DYNACLAD ULTRA HT WIND &WATER SEAL UNDERLAYMENT

#10-13 GP PANCAKEHEAD FASTENER 6" O.C.

DMI DL15 EXPANSION PANEL CLIP30" O.C. MAX (FASTENED WITH 2

#14-13 X 1 1/2" MIN. DP1 FASTENERSPENETRATING WOOD DECK 3/4" MIN)

DL15 DMI PANEL SYSTEM

TWO CONTINUOUSROWS OF BUTYL TAPE

PLYWOOD SHEATHING (5/8"MIN. THICKNESS)

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL TRANSITION DL15 10-00-WA

Page 28: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

3/4"3/4"

NOTEDO NOT ATTACH INTO SOLID SUBSTRATE BELOW.BOOT SHALL NOT INTERSECT STANDING SEAM VERTICAL LEG. INSTALL IN FLAT AREA OF PANEL ONLY.IF USING A SQUARE BOOT DETAIL BE SURE TO SET BOOT IN A DIAGONAL OR DIAMOND TO ALLOW WATER FLOW.

DEKTITE PIPE BOOT OR EQUAL

DMI PANEL SYSTEM

ADJUSTABLE STAINLESS STEEL BAND

1/4-14 X 7/8" STAINLESS PANEL LAPFASTENERS OR EQUAL 2" O.C.

THROUGH COMPRESSION RING (SETIN SEALANT).

CONTINUOUS APPROVED SEALANT

DMI PANEL SYSTEM

1" MIN.

1/4 X 1 1/8" STAINLESS TEKSFASTENERS OR EQUAL 2" O.C.

THROUGH COMPRESSION RINGDEKTITE PIPE BOOT OR EQUAL

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL PIPE BOOT DETAIL DL15 11-00-WA

Page 29: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

SECTION "B"

SECTION "A"

CURB DETAIL INSTRUCTIONS

B

4'-0" WIDTH OR LESS

B

A

6" OVERLAP

EXTEND BACK 2" MIN. PAST EDGE OFRAKE FLASHING

FIELD FOLD AROUND CLEAT

ANTI-SIPHON HEM

DMI PANEL SYSTEMINJECT TWO ROWS OF APPROVED SEALANT IN

VERTICAL SEAM LEG

CLEAT FASTENED AT 6" O.C. SET IN TWOROWS OF BUTYL TAPE

APPROVED UNDERLAYMENTBOX ENTIRE CURB WITH 36" OF SELF

ADHERED ICE AND WATER UNDERLAYMENT1'-0"

FIELD WRAP AROUND FLASHING

CURB VALLEY FLASHING

CURB CAP FLASHING

METAL CURB

CURB CAP FLASHINGCURB APRON

POP RIVET 12" O.C.

DMI PANEL SYSTEM

INJECT APPROVED SEALANT BETWEEN PANELLEG AND Z CLOSURE

BOX END OF PANEL TO FULLLEG HEIGHT AND INJECT

APPROVED SEALANT INCORNERS

Z CLOSURE FASTENED 6" O.C. FOR RAKE EDGEAND 4 FASTENERS PER PANEL FOR APRON.

SET IN TWO ROWS OF BUTYL TAPE.

6" MIN. OPENING BETWEENCURB AND PANEL LEG

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL CURB DL15 12-00-WA

Page 30: FOR STEEL PANELS - Dimensional Metals, Inc.dynaclad ap synthetic underlayment dynaclad ap synthetic underlayment (extend under upper sill and over lower sill) dimensional metals, inc

Install zee closure.

1

2 34

Step 1: Seam PanelStep 3: Notch zee closure.Step 4: Apply two rows of butyl tape to

underside of zee.Step 5:Step 6: Seal all contact points of zee and panel legs.

Also seal over top of panel leg.

5

A

SECTION A-A

TWO ROWS OF BUTYL TAPE

A

FASTENERS PERSHOP DRAWINGS

4

01/17 3"=1'-0"DIMENSIONAL METALS, INC.

PROVEN DEPENDABLE SUSTAINABLE

METAL ENVELOPE SYSTEMS SINCE 1988

WWW.DMIMETALS.COM

Issue/Rev Date: Scale:

Detail:ARCHITECTURAL Z INSTALLATION GUIDE DL15 13-00-WA