Master Builders Solutions by BASF www.master-builders-solutions.basf.us 37 Air Water Barriers MasterSeal ® AWB 660, 665, 660 I Framed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers TABLE OF CONTENTS 2. Typical Joint and Fastener Treatment 2. Typical Expansion Joint 3. Typical Penetration through Wall Construction (Rough Cut) 3. Typical Penetration through Wall Construction (Fabric Only) 4. Typical Penetration through Wall Construction (with Sealant) 4. Typical MasterSeal AWB 975 FIB Application 5. Typical Rough Opening Corner Reinforcement with MasterSeal AWB 975 FIB and MasterSeal AWB 971 FIB 5. Typical Rough Opening Corner Reinforcement with MasterSeal AWB 975 FIB and MasterSeal AWB 970 FIB 6. Typical Window Flange Treatment 6. Typical Window Jamb 7. Typical Window Head 7. Typical Window Sill 8. Typical Window Sill with Closed-Cell Spray Polyureathane Foam Insulation 8. Typical Saddle Application incorporating MasterSeal AWB 971 FIB 9. Typical Saddle Application incorporating MasterSeal AWB 971 FIB 9. Typical Pan Flashing 10. Typical Termination at Grade - MasterSeal AWB 971 FIB Flush with Foundation 10. Typical Termination at Grade - MasterSeal AWB 971 FIB Overlapping Foundation 11. Typical Inside Corner 11. Typical Outside Corner 12. Typical Brick Anchor (installed prior to MasterSeal AWB application) 12. Typical Brick Anchor (installed after MasterSeal AWB application) 13. Typical Termination at Foundation with Brick incorporating Through Wall Flashing - Termination Bar 13. Typical Termination at Foundation with Brick incorporating Through Wall Flashing - MasterSeal AWB 970 FIB 14. Typical Lintel Flashing 14. Typical Multi-Cladding Transition 15. Typical Roof Edge or Parapet Cap Flashing NOTES: • Install BASF materials in accordance with current installation instructions. • Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of MasterSeal AWB products. • The details within represent BASF Corporation - Construction Systems (hereinafter BASF Construction Systems) latest recommendations. They are presented in good faith by BASF Construction Systems. The details are subject to change without notice. BASF Construction Systems accepts no liability for the end use of the details. For conditions not shown, consult BASF Construction Systems for review of specific detail. Technical Bulletin

Upload: others

Post on 25-Apr-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Framed Construction incorporating Fluid-Applied Vapor ... · Framed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers Air/Water-Resistive

Master Builders Solutions by BASF www.master-builders-solutions.basf.us

37 Air WaterBarriers

MasterSeal® AWB 660, 665, 660 IFramed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers

TABLE OF CONTENTS

2. Typical Joint and Fastener Treatment

2. Typical Expansion Joint

3. Typical Penetration through Wall Construction (Rough Cut)

3. Typical Penetration through Wall Construction (Fabric Only)

4. Typical Penetration through Wall Construction (with Sealant)

4. Typical MasterSeal AWB 975 FIB Application

5. Typical Rough Opening Corner Reinforcement with MasterSeal AWB 975 FIB and MasterSeal AWB 971 FIB

5. Typical Rough Opening Corner Reinforcement with MasterSeal AWB 975 FIB and MasterSeal AWB 970 FIB

6. Typical Window Flange Treatment

6. Typical Window Jamb

7. Typical Window Head

7. Typical Window Sill

8. Typical Window Sill with Closed-Cell Spray Polyureathane Foam Insulation

8. Typical Saddle Application incorporating MasterSeal AWB 971 FIB

9. Typical Saddle Application incorporating MasterSeal AWB 971 FIB

9. Typical Pan Flashing

10. Typical Termination at Grade - MasterSeal AWB 971 FIB Flush with Foundation

10. Typical Termination at Grade - MasterSeal AWB 971 FIB Overlapping Foundation

11. Typical Inside Corner

11. Typical Outside Corner

12. Typical Brick Anchor (installed prior to MasterSeal AWB application)

12. Typical Brick Anchor (installed after MasterSeal AWB application)

13. Typical Termination at Foundation with Brick incorporating Through Wall Flashing - Termination Bar

13. Typical Termination at Foundation with Brick incorporating Through Wall Flashing - MasterSeal AWB 970 FIB

14. Typical Lintel Flashing

14. Typical Multi-Cladding Transition

15. Typical Roof Edge or Parapet Cap Flashing

NOTES:

• Install BASF materials in accordance with current installation instructions.

• Unsatisfactory conditions shall be reported to the General Contractor and corrected before the application of MasterSeal AWB products.

• The details within represent BASF Corporation - Construction Systems (hereinafter BASF Construction Systems) latest recommendations. They are presented in good faith by BASF Construction Systems. The details are subject to change without notice. BASF Construction Systems accepts no liability for the end use of the details. For conditions not shown, consult BASF Construction Systems for review of specific detail.

Technical Bulletin

Page 2: Framed Construction incorporating Fluid-Applied Vapor ... · Framed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers Air/Water-Resistive

Technical BulletinFramed Construction incorporating Fluid-Applied VaporPermeable and Impermeable Air/Water-Resistive Barriers

Air/Water-Resistive Barrier Details

TYPICAL JOINT AND FASTENER TREATMENT

TYPICAL EXPANSION JOINT

NOTES

• Ensure all fastener heads are spotted with MasterSeal AWB 660 or MasterSeal AWB 665 or MasterSeal ABW 660 I

• Spot all fasteners not at sheathing joints.

• Embed Sheathing Fabric in MasterSeal AWB 660 or MasterSeal AWB 665 or MasterSeal ABW 660 I

• For more information, reference the MasterSeal AWB Application Guidelines for Joint Treatment and Flashing Rough Openings on Framed Construction technical bulletin.

NOTES

• Provide sufficient slack in the MasterSeal AWB 970 FIB at expansion join to allow for movement.

Framing*

Framing*

Acceptable Sheathing*

Acceptable Sheathing*

9” MasterSeal AWB 970 FIB with MasterSeal 950 P

MasterSeal AWB 660 or MasterSeal AWB 665

Spot Fasteners with MasterSeal AWB 660, MasterSeal AWB, MasterSeal AWB 665, MasterSeal AWB 660 I or MasterSeal AWB 900

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

MasterSeal AWB 971 FIB

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 2 of 16

* By Others

Page 3: Framed Construction incorporating Fluid-Applied Vapor ... · Framed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers Air/Water-Resistive

Technical BulletinFramed Construction incorporating Fluid-Applied VaporPermeable and Impermeable Air/Water-Resistive Barriers

Enershield®-HP / Enershield®-I

step one

step Two

step one

step Two

TYPICAL PENETRATIONTHROUGH WALL CONSTRUCTION (ROUGH CUT)

TYPICAL PENETRATIONTHROUGH WALL CONSTRUCTION (FABRIC ONLY)

Shaved Cured Foam Flush with Sheathing*

Polyurethane Foam*

Pipe*

Pipe*

Pipe*

Framing*

Framing*

MasterSeal AWB 971 FIB

MasterSeal AWB 971 FIB or MasterSeal AWB 900

Acceptable Sheathing*

Acceptable Sheathing*

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

NOTES

• Ensure spray foam is low expansion.

• Provide backer rod and MasterSeal NP 150 between pipe and cladding (by others).

• Embed Sheathing Fabric in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

NOTES

• Cut a square piece of MasterSeal AWB 971 FIB large enough to extend past the pipe by 2” in each direction.

• At the center of the square piece of MasterSeal AWB 971 FIB, pierce a small hole with a blade or scissors.

• With a blade or scissors, cut an “X”. Turn the square about 45° and cut another X. The center point of both “X”s will be the point you pierced previously.

• Insert the pipe through the newly cut square so it is centered with a minimum of 2” on each side with the cut flaps point outward. The square should be flush with the sheathing, See Step 1.

• Embed MasterSeal AWB 971 FIB in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I and coat the flaps around the pipe, See Step 2.

• Wrap a 1” strip of MasterSeal AWB 971 FIB embedded in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I around the flaps.

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 3 of 16

* By Others

Page 4: Framed Construction incorporating Fluid-Applied Vapor ... · Framed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers Air/Water-Resistive

Technical BulletinFramed Construction incorporating Fluid-Applied VaporPermeable and Impermeable Air/Water-Resistive Barriers

Air/Water-Resistive Barrier Details

step one

step Two

TYPICAL PENETRATIONTHROUGH WALL CONSTRUCTION (WITH SEALANT)

TYPICAL MASTERSEAL AWB 975 FIB APPLICATION

Framing*

Acceptable Sheathing*

Sealant at Perimeter of Penetration*

Pipe*

MasterSeal AWB 975 FIB Ready for Installation

Embed MasterSeal AWB 975 FIB in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

Second Application of MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

NOTES

• MasterSeal AWB 660/MasterSeal AWB 665/MasterSeal AWB 660 with MasterSeal AWB 660 I may be used as an alternate to provide an air/water-resistive barrier around penetrations.

• Provide backer rod and MasterSeal NP 150 or Provide backer rod and MasterSeal NP 150, NP 1 or MasterSeal AWB 900 between pipe and cladding (by others).

• Sealant must adhere to both the pipe and sheathing substrate a minimum of 1/2

NOTES

• For more information, reference the MasterSeal AWB Application Guidelines for Joint Treatment and Flashing Rough Openings on Framed Construction technical bulletin.

Spot Fasteners with MasterSeal AWB 660, MasterSeal AWB, MasterSeal AWB 665, MasterSeal AWB 660 I or MasterSeal AWB 900

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 4 of 16

Air/Water-Resistive Barrier Details

step one

step Two

* By Others

Page 5: Framed Construction incorporating Fluid-Applied Vapor ... · Framed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers Air/Water-Resistive

Technical BulletinFramed Construction incorporating Fluid-Applied VaporPermeable and Impermeable Air/Water-Resistive Barriers

Enershield®-HP / Enershield®-I

sTep 1

sTep 3

sTep 2

sTep 4

sTep 1

sTep 3

sTep 2

sTep 4

TYPICAL ROUGH OPENING CORNER TREATMENT WITH MASTERSEAL AWB 975 FIB AND MASTERSEAL AWB 971 FIB

TYPICAL ROUGH OPENING CORNER TREATMENT WITH MASTERSEAL AWB 975 FIB AND MASTERSEAL AWB 970 FIB

Apply MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I to All Sheathing Joints

Apply MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I to Head, Sill, Jambs and Corners (Completely Coat MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I When Applying MasterSeal AWB to Rest of Sheathing

Apply MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I to All Sheathing Joints and Rough Opening Corners

Apply MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I to Rough Opening Head, Sill and Jambs

Embed MasterSeal AWB 970 FIB in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I at Rough Opening Head, Sill and Jambs

Apply a Second Coat of MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I to Head, Sill, Jambs and Corners when Applying MasterSeal AWB to Rest of Sheathing

Apply MasterSeal AWB 950 P, to Rough Opening Corners, Head, Jambs, Sill and Sheathing Around Rough Opening

Apply MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I to All Rough Opening Corners

Embed MasterSeal AWB 970 FIB in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I at Sheathing Joints

Embed MasterSeal AWB 970 FIB in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I at Sheathing Joints

Apply MasterSeal AWB 970 FIB to Rough Opening Head, Sill and Jambs

Embed MasterSeal AWB 970 FIB in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I at Rough Opening Corners

Embed MasterSeal AWB 970 FIB in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I at Rough Opening Corners

NOTES

• Apply MasterSeal AWB 970 FIB over punched stud openings.

• For more information, reference the MasterSeal AWB Application Guidelines for Joint Treatment and Flashing Rough Openings on Framed Construction technical bulletin.

NOTES

• For more information, reference the MasterSeal AWB Application Guidelines for Joint Treatment and Flashing Rough Openings on Framed Construction technical bulletin.

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 5 of 16

* By Others

Page 6: Framed Construction incorporating Fluid-Applied Vapor ... · Framed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers Air/Water-Resistive

Technical BulletinFramed Construction incorporating Fluid-Applied VaporPermeable and Impermeable Air/Water-Resistive Barriers

Air/Water-Resistive Barrier Details

TYPICAL WINDOW FLANGE TREATMENT

TYPICAL WINDOW JAMB

MasterSeal AWB 970 FIB with MasterSeal AWB 950 P or Embed MasterSeal AWB 971 FIB in MasterSeal AWB 660, MasterSeal AWB 665, MasterSeal AWB 660 I or MasterSeal AWB 900

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 IWindow Flange*

Framing*

Acceptable Sheathing*

Continuous Airseal*

Window*

MasterSeal AWB 971 FIB or MasterSeal AWB 970 FIB

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

Window*

Embed MasterSeal AWB 971 FIB in MasterSeal AWB 660, MasterSeal AWB 665, MasterSeal AWB 660 I

NOTES

• Verify rough opening is properly treated prior to window installation. See AWRB-07 or AWRB-08.

• Do not block drainage at window sill.

• Air seal to window by others.

NOTES

• Apply MasterSeal AWB 970 FIB over punched stud openings.

• If blocking is installed prior to MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I application, it shall be treated as a rough opening; verify adhesion before proceeding.

• Embed MasterSeal AWB 971 FIB in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I, or apply MasterSeal AWB 971 FIB over MasterSeal AWB 950 P.

• See AWRB-07 or AWRB-08.

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 6 of 16

* By Others

Page 7: Framed Construction incorporating Fluid-Applied Vapor ... · Framed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers Air/Water-Resistive

Technical BulletinFramed Construction incorporating Fluid-Applied VaporPermeable and Impermeable Air/Water-Resistive Barriers

Enershield®-HP / Enershield®-I

TYPICAL WINDOW HEAD

TYPICAL WINDOW SILL

Framing*

Framing*

Acceptable Sheathing*

Acceptable Sheathing*

MasterSeal AWB 971 FIB

Flashing

Sealant*

Continuous Airseal*

Window*

Window*

Continuous Airseal*

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

MasterSeal AWB 971 FIB, MasterSeal AWB 970 FIB or MasterSeal AWB 900

MasterSeal AWB 971 FIB, MasterSeal AWB 970 FIB or MasterSeal AWB 900

NOTES

• Provide end dams at flashing terminations.

• If blocking is installed prior to MasterSeal AWB 660/ MasterSeal AWB 665/MasterSeal AWB 660 I application, it shall be treated as a rough opening; verify adhesion before proceeding.

• Embed MasterSeal AWB 971 FIB in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I.

• See AWRB-07 or AWRB-08.

NOTES

• Install end/back dams as required.

• If blocking is installed prior to MasterSeal AWB 971 FIB in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I application, it shall be treated as a rough opening; verify adhesion before proceeding.

• If pan flashing is required, see detail AWRB-16.

• See AWRB-07 or AWRB-08.

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 7 of 16

* By Others

Page 8: Framed Construction incorporating Fluid-Applied Vapor ... · Framed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers Air/Water-Resistive

Technical BulletinFramed Construction incorporating Fluid-Applied VaporPermeable and Impermeable Air/Water-Resistive Barriers

Air/Water-Resistive Barrier Details

Air/Water-Resistive Barrier Details

TYPICAL WINDOW SILL WITH CLOSED-CELLSPRAY POLYURETHANE FOAM INSULATION

TYPICAL SADDLE APPLICATIONINCORPORATING MASTERSEAL AWB 971 FIB

NOTES

• Cladding and Flashing not shown for clarity.

• Embed MasterSeal AWB 971 FIB in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I.

• Install Spray Polyurethane Foam Insulation per manufacturer’s installation specifications and recommendations.

• If blocking is installed prior to MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I application, it shall be treated as a rough opening; verify adhesion before proceeding.

NOTES

• Embed MasterSeal AWB 975 FIB in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

• Embed MasterSeal AWB 971 FIB in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

• Two MasterSeal AWB 975 FIB are used, one on each side of the saddle.

Window*

Continuous Air Seal*

MasterSeal AWB 971 FIB

MasterSeal AWB 975 FIB

MasterSeal AWB 971 FIB

Acceptable Sheathing*

Acceptable Sheathing*

Framing*

Framing*

Framing*

BASF Walltite Closed-CellSpray Polyurethane FoamInsulation or Equal*

MasterSeal AWB 660, MasterSeal AWB 665, MasterSeal AWB 660 I or MasterSeal AWB 900

MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 8 of 16

* By Others

Page 9: Framed Construction incorporating Fluid-Applied Vapor ... · Framed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers Air/Water-Resistive

Technical BulletinFramed Construction incorporating Fluid-Applied VaporPermeable and Impermeable Air/Water-Resistive Barriers

Enershield®-HP / Enershield®-I

TYPICAL SADDLE APPLICATIONINCORPORATING MASTERSEAL AWB 970 FIB

TYPICAL PAN FLASHING

NOTES

• All MasterSeal AWB 970 FIB overlaps shall be primed with MasterSeal AWB 950 P.

Visit www.master-builders-solutions.basf.us for a four step expanded version of this detail.

NOTES

• Wrap rough opening in accordance with AWRB-07 or AWRB-08.

• Install MasterSeal NP 150 or equal as depicted onto the sill and jamb to maintain continuity of the air barrier.

• Install pan flashing into the wet sealant. Remove excess sealant as required.

• Install MasterSeal AWB 971 FIB into wet MasterSeal AWB 660 or MasterSeal AWB 665 or MasterSeal AWB 660 I at the jamb end dams.

Acceptable Sheathing*

Framing*

Framing*

MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

MasterSeal AWB 970 FIB with MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

Embed MasterSeal AWB 970 FIB with MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

Acceptable Sheathing*

Acceptable Sheathing*

Treated Rough Opening

Framing*

Framing*

MasterSeal NP 150

Treated Rough Opening

Pan Flashing*

Pan Flashing*

MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 9 of 16

* By Others

Page 10: Framed Construction incorporating Fluid-Applied Vapor ... · Framed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers Air/Water-Resistive

Technical BulletinFramed Construction incorporating Fluid-Applied VaporPermeable and Impermeable Air/Water-Resistive Barriers

Air/Water-Resistive Barrier Details

TYPICAL TERMINATION AT GRADE -SHEATHING FLUSH WITH FOUNDATION

TYPICAL TERMINATION AT GRADE -SHEATHING OVERLAPPING FOUNDATION

Acceptable Sheathing*

Framing*

Flashing*

Foundation*

MasterSeal NP 150

MasterSeal HLM 5000

MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

MasterSeal AWB 660, MasterSeal AWB 665, MasterSeal AWB 660 I or MasterSeal AWB 900MasterSeal 970 FIB with MasterSeal AWB 950 P or Embed MasterSeal 971 FIB in MasterSeal AWB 660, MasterSeal AWB 665, MasterSeal AWB 660 I or MasterSeal AWB 900

MasterSeal 970 FIB with MasterSeal AWB 950 P or Embed MasterSeal 971 FIB in MasterSeal AWB 660, MasterSeal AWB 665, MasterSeal AWB 660 I or MasterSeal AWB 900

MasterSeal AWB 971 FIB

MasterSeal AWB 971 FIB

Acceptable Sheathing*

Backer Rod and MasterSeal NP 150

MasterSeal AWB 971 FIB

MasterSeal AWB 971 FIB

Framing*

Flashing*

MasterSeal HLM 5000

Foundation*

MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

NOTES

• Ensure MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I fully covers MasterSeal AWB 970 FIB at overlap.

• Extend flashing over coated MasterSeal AWB 970 FIB on foundation.

• Embed MasterSeal AWB 971 FIB in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

NOTES

• Ensure MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I fully covers MasterSeal AWB 970 FIB at overlap.

• Extend flashing over coated MasterSeal AWB 970 FIB on foundation.

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 10 of 16

* By Others

Page 11: Framed Construction incorporating Fluid-Applied Vapor ... · Framed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers Air/Water-Resistive

Technical BulletinFramed Construction incorporating Fluid-Applied VaporPermeable and Impermeable Air/Water-Resistive Barriers

Enershield®-HP / Enershield®-I

Acceptable Sheathing*

Framing*

MasterSeal AWB 970 RIB Outside Corner

MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

MasterSeal 971 FIB Embedded in MasterSeal 971 FIB in MasterSeal AWB 660, MasterSeal AWB 665, MasterSeal AWB 660 I

MasterSeal AWB 970 FIB with MasterSeal AWB 950 P

MasterSeal AWB 970 FIB with MasterSeal AWB 950 P

MasterSeal AWB 970 FIB Membrane Drip Edge in a Bed of Continuous MasterSeal NP 150 Sealant

Enershield®-HP / Enershield®-I

TYPICAL INSIDE CORNER

TYPICAL OUTSIDE CORNER

Acceptable Sheathing*

Framing*

MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

Acceptable through Wall Flashing

MasterSeal 971 FIB Embedded in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I

MasterSeal 971 FIB with MasterSeal AWB 950 P

MasterSeal AWB 970 FIB with MasterSeal AWB 950 P

NOTES

• Set acceptable through wall flashing Inside Corner in MasterSeal NP 150 Sealant.

• Lap acceptable through wall flashing membrane at least 2” over Inside Corner.

• Extend MasterSeal AWB 970 FIB Flashing Membrane 8” vertically up the wall (not to scale).

• Apply a bead of MasterSeal NP 150 sealant between MasterSeal AWB 970 FIB Flashing Membrane and Inside Corner to create an airtight and watertight seal.

• Center MasterSeal AWB 970 FIB so half of the width covers MasterSeal AWB 970 FIB Flashing Membrane and half covers the CMU substrate.

• MasterSeal AWB 970 FIB over termination bar can be used instead of MasterSeal AWB 970 FIB (See AWRB-23).

• Lap MasterSeal AWB 971 FIB a minimum of 2” over MasterSeal AWB 970 FIB

• If using a termination bar, MasterSeal AWB 971 FIB must be beneath MasterSeal AWB 970 FIB Flashing Membrane.

Visit www.master-builders-solutions.basf.us for a four step expanded version of this detail.

NOTES

• Set MasterSeal AWB 970 FIB Outside Corner in MasterSeal NP 150 Sealant.

• Lap MasterSeal AWB 970 FIB membrane at least 2” over Outside Corner.

• Extend MasterSeal AWB 970 FIB Flashing Membrane 8” vertically up the wall (not to scale).

• Apply a bead of MasterSeal NP 150 sealant between MasterSeal AWB 970 FIB Flashing Membrane and Inside Corner to create an airtight and watertight seal.

• Center MasterSeal AWB 970 FIB so half of the width covers MasterSeal AWB 970 FIB Flashing Membrane and half covers the CMU substrate.

• MasterSeal AWB 970 FIB over termination bar can be used instead of MasterSeal AWB 970 FIB (See AWRB-23).

• Lap MasterSeal AWB 971 FIB a minimum of 2” over MasterSeal AWB 970 FIB

• If using a termination bar, MasterSeal AWB 971 FIB must be beneath MasterSeal AWB 970 FIB Flashing Membrane.

Visit www.master-builders-solutions.basf.us for a four step expanded version of this detail.

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 11 of 16

* By Others

Page 12: Framed Construction incorporating Fluid-Applied Vapor ... · Framed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers Air/Water-Resistive

Technical BulletinFramed Construction incorporating Fluid-Applied VaporPermeable and Impermeable Air/Water-Resistive Barriers

Air/Water-Resistive Barrier Details

step one

step Two

step Three

option one

option Two

option Three

TYPICAL BRICK ANCHOR(INSTALLED PRIOR TO MASTERSEAL AWB APPLICATION)

TYPICAL BRICK ANCHOR(INSTALLED AFTER TO MASTERSEAL AWB APPLICATION)

NOTES

• Seal brick tie by embedding MasterSeal AWB 971 FIB in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I or sealing fastener head with MasterSeal AWB 900

• Consult the brick tie manufacturer for proper attachment.

NOTES

• For more information, see MasterSeal AWB Fastener Self-Sealing technical bulletin.

• Consult the brick anchor manufacturer for proper attachment.

• Additional MasterSeal AWB or MasterSeal AWB 900 may be post applied at anchor points.

• Option 3: Apply MasterSeal AWB 970 FIB to MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I prior to application of brick anchor.

Acceptable Sheathing*

Brick Tie*

Brick Anchor*

Brick Anchor*

Brick Tie*

Framing*

Framing*

MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

MasterSeal AWB 970 FIB with MasterSeal AWB 950 P or Embed MasterSeal 971 FIB in MasterSeal AWB 660, MasterSeal AWB 665, MasterSeal AWB 660 I

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 12 of 16

* By Others

Page 13: Framed Construction incorporating Fluid-Applied Vapor ... · Framed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers Air/Water-Resistive

Technical BulletinFramed Construction incorporating Fluid-Applied VaporPermeable and Impermeable Air/Water-Resistive Barriers

Enershield®-HP / Enershield®-I

TYPICAL TERMINATION AT FOUNDATION WITHBRICK INCORPORATING TWF - TERMINATION BAR

TYPICAL TERMINATION AT FOUNDATION WITHBRICK INCORPORATING TWF - SHEATHING FABRIC

NOTES

• Air space between sheathing and brick per design (not shown).

• Extend flashing vertically up the backing to 203 mm (8”) minimum height.

NOTES

• Air space between sheathing and brick per design (not shown).

• Extend flashing vertically up the backing to 203 mm (8”) minimum height.

Acceptable Sheathing*

Acceptable Sheathing*

Termination Bar*

Continuous Insulation*

Continuous Insulation*

Acceptable Through Wall Flashing Membrane. Flashing primer as required

MasterSeal AWB 950 P

MasterSeal AWB 950 P

MasterSeal NP 150

MasterSeal NP 150

Brick*

Brick*

Foundation*

Foundation*

MasterSeal NP 150 or MasterSeal AWB 900

MasterSeal NP 150 or MasterSeal AWB 900

MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

MasterSeal AWB 970 FIB with MasterSeal AWB 950 P

MasterSeal AWB 970 FIB with MasterSeal AWB 950 P

MasterSeal AWB 970 FIB with MasterSeal AWB 950 P

MasterSeal AWB 970 FIB

MasterSeal HLM 5000 High Build System

MasterSeal HLM 5000 High Build System

Acceptable Through Wall Flashing Membrane. Flashing primer as required

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 13 of 16

* By Others

Page 14: Framed Construction incorporating Fluid-Applied Vapor ... · Framed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers Air/Water-Resistive

Technical BulletinFramed Construction incorporating Fluid-Applied VaporPermeable and Impermeable Air/Water-Resistive Barriers

Air/Water-Resistive Barrier Details

TYPICAL THROUGH WALL FLASHING AT HEAD

TYPICAL EIFS ABUTMENT TO BRICK WITH CONTINUOUS INSULATION

NOTES

• Embed MasterSeal AWB 971 FIB in MasterSeal AWB 660, MasterSeal AWB 665 or MasterSeal AWB 660 I.

• Air space between sheathing, continuous insulation and brick per design.

• Center MasterSeal AWB 970 FIB so half of the width covers MasterSeal AWB 970 FIB Flashing Membrane and half covers the primed substrate.

• MasterSeal AWB 970 FIB Flashing Membrane can be folded to create an end dam. Ensure that seams are sealed with MasterSeal NP 150.

NOTES

• Air space between insulation and brick per design.

• Embed MasterSeal AWB 971 FIB in MasterSeal AWB 660 or MasterSeal AWB 665 or MasterSeal AWB 660 I.

• Up to 12” of EPS thickness can be used with BASF EIFS.

Acceptable Sheathing Over Frame*

Acceptable Sheathing*

Weeps*

Metal Flashing*

MasterSeal NP 150

Lintel*

Window*

Brick*

Brick*

End Dams Set in MasterSeal NP 150*

BASF Walltite Closed-Cell Spray Polyurethane Foam Insulation or Equal

MasterSeal AWB 971 FIB

Framing*

MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

MasterSeal AWB 971 FIB

MasterSeal AWB 970 FIB over MasterSeal AWB 950 P

Senergy, Finestone, orAcrocrete EIFS*

4” MasterSeal AWB 970 FIB or MasterSeal AWB 900 to overlap through wall flashing

MasterSeal AWB 970 with MasterSeal AWB 950 P or Embed MasterSeal AWB 971 FIB with MasterSeal AWB 660, MasterSeal AWB 665, MasterSeal AWB 660 I or MasterSeal AWB 900

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 14 of 16

* By Others

Page 15: Framed Construction incorporating Fluid-Applied Vapor ... · Framed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers Air/Water-Resistive

Technical BulletinFramed Construction incorporating Fluid-Applied VaporPermeable and Impermeable Air/Water-Resistive Barriers

Enershield®-HP / Enershield®-I

TYPICAL ROOF EDGE ORPARAPET CAP FLASHING

NOTES

• MasterSeal AWB 970 FIB or MasterSeal AWB 900 may be used as an alternate to provide an air/water-resistive barrier at transition of sheathing to blocking.

• Ensure continuity of air barrier is maintained.

• Avoid solvent-based adhesives/primers where roofing laps MasterSeal AWB.

Acceptable Sheathing*

Framing*

Blocking*

Continuous Cleat*

Metal Roof Edge*

MasterSeal NP 150 Between Roof Edge and Cladding*

MasterSeal AWB 971 FIB

MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

Lap and Seal Roof Membrane Air Barrier* Onto MasterSeal AWB 660, MasterSeal AWB 665, or MasterSeal AWB 660 I

Master Builders Solutions by BASF www.master-builders-solutions.basf.us Page 15 of 16

* By Others

Page 16: Framed Construction incorporating Fluid-Applied Vapor ... · Framed Construction incorporating Fluid-Applied Vapor Permeable and Impermeable Air/Water-Resistive Barriers Air/Water-Resistive

® = Registered trademark of the BASF-Group in many countries.© 2014 BASF Corporation | Construction Systems | rev 05/14

BASF Corporation 889 Valley Park Drive, Shakopee, MN 55379 Customer Service 1(800) 433.9517 Construction Systems www.master-builders-solutions.basf.us Technical Service 1(800) 243.6739

Technical BulletinFramed Construction incorporating Fluid-Applied VaporPermeable and Impermeable Air/Water-Resistive Barriers

HEALTH , SAFETY AND ENVIRONMENTAL Read, understand and follow all Safety Data Sheets and product label information for this product prior to use. The SDS can be obtained by visiting www.master-builders-solutions.basf.us, e-mailing your request to [email protected] or calling 1(800) 433-9517. Use only as directed. For medical emer-gencies only, call ChemTrec® 1(800)424-9300.

LIMITED WARRANTY NOTICE BASF warrants this product to be free from manu-facturing defects and to meet the technical proper-ties on the current Technical Data Guide, if used as directed within shelf life. Satisfactory results depend not only on quality products but also upon many factors beyond our control. BASF MAKES NO OTHER WARRANTY OR GUARANTEE, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MER-CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ITS PRODUCTS. The sole and exclusive remedy of Purchaser for any claim concerning this product, including but not limited to, claims alleging breach of warranty, negligence, strict liability or otherwise, is the replacement of product or refund of the purchase price, at the sole option of BASF. Any claims concerning this product must be received in writing within one (1) year from the date of shipment and any claims not presented within that period are waived by Purchaser. BASF WILL NOT BE RESPONSIBLE FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL (INCLUDING LOST PROFITS) OR PUNITIVE DAMAGES OF ANY KIND.

Purchaser must determine the suitability of the prod-ucts for the intended use and assumes all risks and liabilities in connection therewith. This information and all further technical advice are based on BASF’s present knowledge and experience. However, BASF assumes no liability for providing such information and advice including the extent to which such infor-mation and advice may relate to existing third party intellectual property rights, especially patent rights, nor shall any legal relationship be created by or arise from the provision of such information and advice. BASF reserves the right to make any changes ac-cording to technological progress or further develop-ments. The Purchaser of the Product(s) must test the product(s) for suitability for the intend-ed application and purpose before proceeding with a full application of the product(s). Performance of the product described herein should be verified by testing and carried out by qualified experts.

® = Registered trademark of the BASF-Group in many countries.© 2016 BASF Corporation | Construction Systems | Part no. 14000256 rev 12/16