Burners Free flame burners EMB (E3004 rev. 09 - 18/01/2018)

Upload: others

Post on 21-Sep-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

Burners

Free flame burners

EMB (E3004 rev. 09 - 18/01/2018)

Page 2: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 2

GENERAL WARNINGS:

¾¾ All installation, maintenance, ignition and setting mustbe performed by qualified staff, respecting the norms

present at the time and place of the installation.

¾¾ To avoid damage to people and things, it is essentialto observe all the points indicated in this handbook. The

reported indications do not exonerate the Client/User

from observing general or specific laws concerning acci-

dents and environmental safeguarding.

¾¾ The operator must wear proper DPI clothing (shoes,helmets...) and respect the general safety, prevention

and precaution norms.

¾¾ To avoid the risks of burns or high voltage electrocu-tion, the operator must avoid all contact with the burner

and its control devices during the ignition phase and

while it is running at high temperatures.

¾¾ All ordinary and extraordinary maintenance must beperformed when the system is stopped.

¾¾ To assure correct and safe use of the combustionplant, it is of extreme importance that the contents of this

document be brought to the attention of and be meticu-

lously observed by all personnel in charge of controlling

and working the devices.

¾¾ The functioning of a combustion plant can be dange-rous and cause injuries to persons or damage to equip-

ment. Every burner must be provided with certified com-

bustion safety and supervision devices.

¾¾ The burner must be installed correctly to prevent anytype of accidental/undesired heat transmission from the

flame to the operator or the equipment.

¾¾ The performances indicated in this technical docu-ment regarding the range of products are a result of

experimental tests carried out at ESA-PYRONICS. The

tests have been performed using ignition systems, flame

detectors and supervisors developed by ESA-PYRO-

NICS. The respect of the above mentioned functioning

conditions cannot be guaranteed if equipment, which is

not present in the ESA-PYRONICS catalogue, is used.

CONTACTS / SERVICE:

To dispose of the product, abide by the local legislations

regarding it.

DISPOSAL:

Esa S.p.A.

Via Enrico Fermi 40

24035 Curno (BG) - Italy

Tel +39.035.6227411

Fax +39.035.6227499

[email protected]

ESA Belgium

Zoning Industriel, 4ème rue

B-6040 Jumet - Belgium

Tel +32.71.256970

Fax +32.71.256979

[email protected]

www.esapyronics.com

GENERAL NOTES:

¾¾ In accordance to the internal policy of constant quali-ty improvement, ESA-PYRONICS reserves the right tomodify the technical characteristics of the present docu-ment at any time and without warning.

¾¾ It is possible to download technical sheets whichhave been updated to the latest revision from the www.esapyronics.com website.

¾¾ The EMB products have been designed, manufactu-red and tested according to the most correct construc-tion practices and following the applicable requirementsdescribed in UNI EN 746-2-2010 “Industrial heating pro-cess equipment - Part 2: Safety requirements for com-bustion and for the handling and processing of fuels’.We emphasize that the burners described in this datasheet are provided as independent units and areexcluded from the scope of the Machine Directive2006/42/EC not having any mobile items that are notexclusively manual.

¾¾ Certified in conformity with the UNI EN ISO 9001Norm by DNV GL.

CERTIFICATIONS:

The products conform to the requests for the Euroasia market

(Russia, Belarus and Kazakhstan).

Page 3: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 3

APPLICATIONS

The EMB are metallic gas burners are used for direct

heating. These burners allow excess air, stoichiomentric

and excess gas regulation. Depending on the size and

use, this type of burner can be used for natural gas and

LPG combustion (in the standard version) and other

types of gaseous combustive agents with heating diffe-

rent properties (special versions on request).

¾¾Ceramic furnaces or fibre cover treatment furnaces.

¾¾Tunnel or chariot furnaces.

¾¾Dryers.

¾¾Textile and dry cleaning machines (Rameause).

¾¾Stretching furnaces.

CHARACTERISTICS

GENERAL:

¾¾Capacity: From 20 to 2.500 kW

¾¾Temperature limit: 1.000°C

¾¾Air and gas pressure to burner: 45mbar

¾¾Flow ratio: 8 : 1

¾¾Flame speed: 50-60 m/s

¾¾Low CO2 content: <10PPM (@ 3% O2 )

¾¾Excess air: up to 400%

MATERIAL COMPOSITION:

¾¾Mixer body: Cast iron G25

¾¾Gas collector: Cast iron G25

¾¾Flameproof tube: AISI304 / AISI310

¾¾Combustion head: AISI310

¾¾Fixing flange: Fe 360

F3004I03

F3004I04

Page 4: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 4

BLOCK HOLDER BURNER VERSION (EMB-BH)

The EMB-BH are gas burners used for direct heating.

These burners allow excess air, stoichiomentric and

excess gas regulation. Depending on the size and use,

this type of burner can be used for natural gas and LPG

combustion (in the standard version) and other types of

gaseous combustive agents with heating different proper-

ties (special versions on request). The burner is pronded

with concrete block holder for special high temperature

application such as:

¾¾NOx galvanizing lines.

¾¾Ceramic furnaces or fibre cover treatment furnaces.

¾¾Tunnel or car bottom furnaces.

¾¾Dryers.

¾¾Stretching furnaces.

¾¾Treatment furnaces.

F3400I05

F3004I06

CHARACTERISTICS

GENERAL:

¾¾Temperature limit: 1.300°C

¾¾Air and gas pressure to burner: 45mbar

¾¾Flow ratio: 8 : 1

¾¾Flame speed: 50-60 m/s

¾¾Excess air: up to 400%

¾¾Excess gas: up to 20%

¾¾Preheated air up to: 550°C

MATERIAL COMPOSITION:

¾¾Mixer body: Cast iron G25

¾¾Gas collector: Cast iron G25

¾¾Flameproof tube: AISI304 / AISI310

¾¾Combustion head: AISI310

¾¾Fixing flange: Fe

¾¾Refractory block: T.max 1750°C

Page 5: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

The EMB burners develop the maximum capacity in stoi-

chiometric ratio with 45mbar of air pressure. This implies

the use of low prevalence blowers which are also inex-

pensive; the setting is simplified due the special differen-

tial pressure plugs that allow the measurement of air and

gas flow.

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 5

PARAMETER CAPACITY AND FLAME LENGTH

DESCRPTION

The EMB burner ignition takes place through a high ten-

sion discharge obtained via an electrode and the detec-

tion is performed by another electrode, or by UV scanner

(in block holder version).

ModelCapacity

[kW]

Flame length

[mm]

Flame tube outlet diameter

[mm]

Flame speed[m/s]

Flame ignition and detection

EMB-0 20 150 ÷ 200 37 40 N.1 WAND electrode

EMB-1 30 300 ÷ 400 43 42 N.2 WAND electrodes

EMB-2 80 500 ÷ 700 64 51 N.2 WAND electrodes

EMB-3 150 700 ÷ 1000 94 44 N.2 EN electrodes

EMB-4 300 1000 ÷ 1250 122 52 N.2 EN electrodes

EMB-5 400 1200 ÷1500 122 69 N.2 EN electrodes

EMB-6 600 1500 ÷ 2000 160 56 N.2 EN electrodes

EMB-7 900 1800 ÷ 2400 187 67 N.2 EN electrodes

EMB-8 1.500 2200 ÷ 3000 211 88 N.2 EN electrodes

EMB-9 2000 2800 ÷ 3500 250 75 N.2 EN electrodes

EMB-10 2500 3000 ÷ 3800 250 80 N.2 EN electrodes

The adoption of flame control systems is highly recom-

mended in all plants operating at temperatures lower

than 750°C (UNI EN746/2 Regulation).

The flame lengths and velocities are approximate, they

refer to burners fed by natural gas that are placed in open

air and function in stoichiometric ratio at nominal capaci-

ty.

In special applications, mono-electrodes for the ignition

and flame detection are used or else an electrode for

flame ignition and a UV photocell for the flame detection

is used.

The EMB burners are "nozzle mix" type burners. The fuel

and combustive agents are mixed at the combustion head

to avoid dangerous flame flashbacks. Furthermore, the

special shape of the combustion head allows regulation in

stoichiometric ratio as well as in air excess or gas excess.

The burners can work also with preheated combustion air

up to 550°C.

Page 6: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 6

BURNER PERFOMANCE

¾¾Chamber temperature 1000°C

¾¾NOx < 200 mg/Nm3 [O2 = 3% ref.]

¾¾Room air temperature

MAXIMUM CAPACITY

MINIMUM CAPACITY

The flame capacity, length and speed refer to a natu-

ral gas fed burner (8600 Kcal/Nm³) placed in a com-bustion chamber at zero pressure above sea level,

functioning with 10% of excess air.

Free flame applicationBurner model

EMB-0 EMB-1 EMB-2 EMB-3 EMB-4 EMB-5 EMB-6 EMB-7 EMB-8 EMB-9 EMB-10

Burner capacity (2% O2) [kW] 20 30 80 150 300 400 600 900 1500 2000 2500

Combustion air flow [Nm3/h] 22 33 88 165 330 440 660 990 1650 2200 2750

Gas flow [Nm3/h] 2 3 8 15 30 40 60 90 150 200 250

Burner air inlet pressure [mbar] 45

∆p flange gas measurement [mbar] 10

Max capacity

Free flame applicationBurner model

EMB-0 EMB-1 EMB-2 EMB-3 EMB-4 EMB-5 EMB-6 EMB-7 EMB-8 EMB-9 EMB-10

Burner capacity(2% O2) [kW] 2 3 8 15 30 40 60 90 150 200 250

Combustion air flow [Nm3/h] 2,2 3,3 8,8 16,5 33 44 66 99 165,5 220 275

Gas flow [Nm3/h] 0,2 0,3 0,8 1,5 3,0 4,0 6,0 9,0 15,0 20 25

Burner air inlet pressure [mbar] 0,5

∆p flange gas measurement [mbar] 0,1

Min capacity

Page 7: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 7

AIR CAPACITY TABLE

G3004I02

0,1

1

10

100

1 10 100 1.000 10.000

EM

B-0

EM

B-1

EM

B-2

EM

B-3

EM

B-4

EM

B-5

EM

B-6

EM

B-7

EM

B-8

EM

B-9

EM

B-1

0

Total air flow (burner + ejector) @ 30 °C P.S.= 1 [Nm3/h]

Burn

er

feedin

g p

ressure

[m

bar]

NATURAL GAS CAPACITY TABLE

EM

B-0

EM

B-1

EM

B-2

EM

B-3

EM

B-4

EM

B-5

EM

B-6

EM

B-7

EM

B-8

1,5

0,1

1

10

0,1 1 10 100

EM

B-9

EM

B-1

0

G3004I01

Natural gas flow @ 20 °C P.S.=0,6 [Nm3/h]

Diffe

ren

tia

l p

ressu

re a

t o

rifice

flo

w m

ete

r [m

ba

r]

Page 8: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 8

AIR INLET

1 2

3

5

6

7

13

1410

9

12

11

TO

OT

HE

R B

UR

NE

RS

IGN

DET

4

15

8

GAS INLET

SINGLE ZONE REGULATION

SLOW OPENING

FLOW SCHEME -FREE FLAME METALLIC BURNER

Pos. Description Included Not included

1 Main gas interception ball valve X

2 Balanced modulator X

3 Impulse line X

4 Servo-controlled air regulation butterfly valve X

5 Electric servo-control X

6 Single burner gas interception ball valve X

7 Main burner safety gas solenoid valve X

8 DP gas measurement calibrated flange X

9 Gas passage limiting device X

10 Manual air regulation butterfly valve X

11 DP inlet air pressure measurement calibrated orifice X

12 Free flame burner X

13 Ignition transformer X

14 Flame control X

15 Premix air regulation kit (only LPG versions) X

D3004I01

Page 9: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 9

FLOW SCHEME -FREE FLAME METALLIC BURNER

Pos. Description Included Not included

1 Main gas interception ball valve X

2 Balanced modulator X

3 Impulse line X

4 Servo-controlled air regulation butterfly valve X

5 Electric servo-control X

6 Single burner gas interception ball valve X

7 Main burner safety gas solenoid valve X

8 DP gas measurement calibrated flange X

9 Gas passage limiting device X

10 Manual air regulation butterfly valve X

11 DP inlet air pressure measurement calibrated orifice X

12 Free flame burner X

13 Ignition transformer X

14 Flame control X

15 Premix air regulation kit (only LPG versions) X

AIR INLET

1 2

5

13

14

9

12

11

IGN

DET

15

GAS INLET

83

SINGLE BURNER REGULATION

D3004I02

Page 10: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 10

WARNINGS

¾¾ The EMB burner ignition must always be carried outat minimum power, modulating towards the maximum,

facilitating the ignition and reducing the outlet overpres-

sures. Thus it is opportune to use slow opening solenoid

valves on the fuel line.

¾¾ The passing from minimum to maximum power andvice-versa, must be gradual and not instantaneous. In

double stage regulations, the use of MRBV regulation

valves (data sheet E1302) is suggested.

¾¾ For all low temperature applications (up to 750°C),the burner ignition and the fuel gas solenoid valve com-

mands must be performed via a certified burner control

device.

¾¾ To avoid possible damage to burners, make sure thatthe blower does not send them air that may be fouled by

combustion products, oils, solvents or other. To avoid

these phenomena from taking place, possibly install the

blower or the suction duct outside the establishment and

far from the exhaust pipes.

¾¾ Check the correct connection of the feeding lines afterinstallation. Before switching the burner on, check that

the combustive air and fuel gas pressure values are cor-

rect (Pag.05).

¾¾ The burner can only function within the indicatedpower range. Functioning at lower or higher powers

could compromise the burner performance as well as its

life span. In which case, the general warrantee condi-

tions will automatically expire and ESA will not be held

responsible for any damage to persons or things.

¾¾ If there is trouble with other devices during the burnerstart up phase, use the connector with anti disturbance

filter for the high-tension (HT) cable connection of the

ignition electrode.

¾¾ Avoid burner ignition close to each other so as not toheat the ignition command system devices (solenoid val-

ves and transformers). Prewash time lapse + first safety

time lapse + min. of 5 sec. = time lapse between one igni-

tion and another. (however, do not attempt more than 2

ignitions during a 30sec. time lapse).

¾¾ Make sure the power supply is TURNED OFF whenintervening on the burner and its devices. In case of bur-

ner malfunctioning, follow the indications in the

'Maintenance' chapter of the present manual or contact

ESA-PYRONICS assistance.

¾¾ Any modification or repair done by third parties cancompromise the application safety and automatically

cause the general warrantee conditions to expire.

Page 11: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 11

INSTALLATION

The EMB series burners are supplied with a special fur-nace wall fixing flange. The light obtained for the burnerhousing must leave open space around the burner. Thisspace has then to be filled with ceramic-fibre.

For the installation carefully follow the instructions below:

1 - Place the EMB burners far from heat sources and pro-ducts such as: liquids, solvents or corrosive gases.

2 - Make sure that the housing dimensions and thedistance between the centers of the feeding pipes corre-spond to what is specified in the "Overall dimensions"chapter.

3 - Assemble the burner on the furnace wall (pos. 01)interposing a ceramic fibre gasket between the atta-chment flange and the furnace wall (pos.02) *. During theburner insertion phase check that the insulation previou-sly wrapped around the outside is not altered nor dama-ged. Once the spacer has been fixed onto the furnace,from the inside of the combustion chamber, seal any pos-sible cracks that may be left between the wall and thespacer with ceramic fibre.

4 - Connect the combustion air and fuel gas inlet piping,interposing, if possible, dilation joints in AISI.

5 - Connect electricity to the ignition electrode and to theuv-scan detector making sure not to pass the conductorsnear heat sources.

6 - Check that the burner body and all its metallic ele-ments are earthed with appropriate conductors.

7 - The connecting cable from the ignition transformer tothe electrode must be specific for high tension and notscreened. It must not be more than 1 metre long; other-wise the ignition transformer must be positioned near theburner. The high tension cable must be placed far fromthe power cables and not in metallic ducts. Ideally itshould be left in open air.

8 - For further information please consult the technicaldata sheet concerning the ignition transformers.

9 - Connect electricity to the ignition electrode and to theuv-scan detector making sure not to pass the conductorsnear heat sources.

NOTE: * The furnace wall seal, unless specifically reque-sted by the customer, is not included in the burner supply.

01

02

D3004I03

FIBER CERAMICBY CUSTOMER

80

WALL THICKNESS

D3004I04

Page 12: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 12

START-UP - SETTING

PREMIX AIR FLOW SETTING WHERE SCHEDULED (LPG BURNERS)

The procedures indicated in the following chapter must

be carried out by expert technicians. The non-observan-

ce of the instructions given can provoke dangerous con-

ditions.

1 - Check that the combustion air pressure exiting the

blower and the combustive fuel feeding pressure are both

within the allowed range.

2 - Adjust the working pressure and the safety device

pressure of the combustion plant, whether there is one

per burner or one for the whole plant i.e. gas pressure

reduction gear, block valve, relief valve, pressure swit-

ches etc. Simulate the intervention of all the safety devi-

ces including the intervention of the safety over tempera-

ture, checking that the fuel safety block devices act pro-

perly.

3 - Place the motorized air regulation valve in its maxi-

mum opening position and, via the gate valve, regulate

the inlet air pressures to the burner, referring to the

values indicated in the "burner performance" chapter for

the maximum capacities (pag.05).

4 - Place the motorized air regulation valve in its mini-

mum opening position and regulate its opening to obtain

(in burner and ejector inlet) the relative minimum power

pressure.

5 -Activate the burner control device and attempt the igni-

tion until the burner switches on. While attempting to igni-

te the burner, act on the gas adjustment valve and, star-

ting from the totally closed position, open it gradually until

the burner ignites.

6 - Fully open the air regulation valve and adjust the maxi-

mum fuel capacity via the gas adjustment valve, checking

the differential pressure created on the calibrated gas

flange.

7 - Double check that, at minimum and maximum power,

the burner inlet pressure corresponds to the values in the

in the 'Parameter capacity" chapter. These values may be

different depending on whether the burner is on or off.

8 - If necessary, with all burners turned onto the same

power, analyse the combustion products in the chamber

(where possible).

9 - Repeatedly attempt ignition at minimum burner power,

with maximum amplitude, to check the ignition reliability

and flame stability during the adjustment.

The premix line is supplied with the LPG burners. The

setting must be carried out with burner off and in mini-

mum flow conditions. The premix line must be fed by an

inlet necessarily placed upstream the air flow regulation

valve, whether it is in zone or interlocked by the main bur-

ner.

1. Place the burner in the minimum combustion air flow

conditions.

2. Open the premix air tap.

3. Regulate the micrometric pin valve according to the fol-

lowing conditions:

4. Check, however, that at minimum power, the burner

does not create black smoke on the combustion head

and on the electrodes. In case this should occur, increa-

se the premix air setting.

EMB-1: Gas body pressure = 2 mbar

EMB-2: Gas body pressure = 2 mbar

EMB-3: Gas body pressure = 2 mbar

EMB-4: Gas body pressure = 2 mbar

EMB-5: Gas body pressure = 2 mbar

EMB-6: ∆p = 6.5 mbar

EMB-7: ∆p = 2.5 mbar

EMB-8: ∆p = 5 mbar

EMB-9: ∆p=5 mbar

EMB-10: ∆p=5 mbar

Page 13: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 13

GENERAL MAINTENANCE PLAN

Operation Type Advised time Notes

High tension electrode connection O annualcheck integrity of outer plastic and oxidi-

zation of internal electrode terminal.

Electrode ignition / detection O annual replace if the kantal terminal is worn.

Flanged tube combustion head O annual

during furnace stop, check that the two

elements do not show signs of oxidiza-

tion caused by high temperature.

Burner setting O annual

check the correctness of air and gas

pressures or oxygen content with a sui-

table analyzer.

Premix air setting (where scheduled) O annualcheck the correctness of the calibration

of the premix line with the burner off.

Replacement of gas side gaskets (**) S biennale

check that the gaskets are free of air

leaks and that there is no vulcanization

in the rubber.

NOTES:

Key: O=ordinary / E=extraordinary

(*) it is suggested that the gaskets on the gas side are replaced after every disassembly of the gas feeding line.

(**) use high temperature gaskets

Page 14: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 14

ORDINARY MAINTENANCE

For correct dismantling and better maintenance of the

EMB burner, meticulously follow the instructions below

with the plant turned off.

IGNITION AND FLAME DETECTION ELECTRODE

REPLACEMENT

1 - Check that the burner control device is disconnected.

2 - Disconnect electrical supply to the electrodes

(pos.01).

3 - Unscrew the connector (pos.02) at the base of the gas

collector, removing the electrode (pos.03).

4 - Replace the faulty electrode (pos.03) paying attention

to the correct repositioning of the new electrode.

5 - Reconnect the electrical supply (pos.01).

6 - Check the electrode's correct flame ignition/detection.

01 02 03

D3004I05

Page 15: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 15

For correct dismantling and better maintenance of the

EMB burner, meticulously follow the instructions below

with the plant turned off.

BURNER-SHUTDOWN

For correct dismantling and better maintenance of

the EMB burners, meticulously follow the instruc-

tions with the plant turned off. In shutdown condi-

tions of the burner refer to the burner control device

indications and to the relative manual to identify the

cause. The main cases are indicated here below:

¾¾ Illegal flame detection: the shutdown is due to an ille-

gal flame detection during the phases prior to ignition or

after the turning off. The causes are within the detection

system (broken or faulty sensor or presence of humidi-

ty), or in the gas draw from the solenoid safety valve,

which allows the burner to remain turned on.

EXTRAORDINARY MAINTENANCE

¾¾Failed ignition: shutdown is caused due to the fact

that no flame has been created during the starting pro-

cess. The causes can be found in the start-up system

(spark absence, faulty electrodes or incorrect position),

in the bad setting of the fuel and combustion flow or in

the detection system (faulty sensor or interrupted

cables). More precisely, in the first two cases the flame

is not ignited, while in the last case the flame is created

but the burner control device is unable to detect it.

¾¾Flame signal loss: shutdown due to the loss of flame

signal during the normal functioning of the burner. The

causes can be found in the combustion air flow adju-

stment (rapid flow variations, adjustment out of allowed

range). They can also be found in the detection system

(faulty, dirty or badly positioned sensors).

Page 16: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 16

EMB-0 OVERALL DIMENSIONS

86

Ø26

9

Ø70

± 5

120 (

a)

Nr.4 Ø10 holes (a)

Air inletRp 1"

Gas inlet

Rp 3/8"

100 (

a)

Ø42.4

X=

Wall

thic

kness

73

8

159

Min

. 100 (

b)

Min

. 100 (

b)

Ø47.5

Gas inletR 3/8"

Rp 3/8"

Ø54

Gas orifice flowmeter (included)

Assembly by customer

75

NOTES:

(a) Suitable on

customer request

(b) by customer

D3004I06

Page 17: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 17

EMB-1-CH4 OVERALL DIMENSIONS

RA

Ø 48.3

70

±5

Nr.4 holes Ø 13

83

R 1/2"

Air inlet

Ø 60

88

10

Rp 1.1/2"

Gas inlet Rp 1/2"

17

1

X=

Wa

ll th

ickn

ess

Min

.10

0 (

b)

Min

.10

0 (

b)

43

.5 Gas inlet

15

0 (

a)

28

1

Gas orifice flowmeter (included)

Assembly by customer

107

86

NOTES:

(a) Suitable on

customer request

(b) by customer

12

0 (

a)

D3004I07

Page 18: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 18

EMB-1 LPG OVERALL DIMENSIONS

RA

Ø 48.3

70

±5

N°4 holes Ø 13 onD.B.C Ø120 (a)

83

R 1/2"

Air inlet

Ø 60

88

10

Rp 1.1/2"

Gas inlet Rp 1/2"

171

X=

Wall

thic

kness

Min

.100 (

b)

Min

.100 (

b)

43.5

Gas inlet

150 (

a)

142 ±

5

31

5

NOTES:

(a) Suitable oncustomer request

(b) by customer

Gas orifice

flowmeter (included)

Assembly by customer

107

90

Premixing air inlet Rp 1/4"

D3004I08

Page 19: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 19

EMB-2-CH4 OVERALL DIMENSIONS

Ø70

RA

Rp 1.1/2"

10

88

8

19

6

14

0 (

a)

17

0 (

a)

AIR INLET

X =

Wa

ll th

ickn

ess

N°4 holes Ø13 (a)

10

Rp 1/2"GAS INLET

Ø82

R 1/2"Gas inlet

10

0 M

in.

(b)

44

10

0 M

in.

(b)

107

103

Gas orifice flowmeter (included)

Assembly by client

31

6

70

±5

NOTES:

(a) Suitable onclient request

(b) by client

D3004I09

Page 20: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 20

EMB-2 LPG OVERALL DIMENSIONS

Ø70

RA

Rp 1.1/2"

10

88

8

19

6

140 (

a)

170 (

a)

AIR INLET

X =

Wall

tig

htn

ess

Nr.4 holes Ø13 (a)

10

Rp 1/2"GAS INLET

Ø82

106.5

103

31

6

70

±5

Premixing air inlet Rp 1/4"

142±5

Nr.4 holes Ø 13 onD.B.C Ø120 (a)

R 1/2"Gas inlet

10

0 M

in.

(b)

44

10

0 M

in. (b

)Gas orifice flowmeter (included)

Assembly by client

NOTES:

(a) Suitable onclient request

(b) by client

D3004I10

Page 21: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 21

EMB-3-CH4 OVERALL DIMENSIONS

AIR INLET

GAS INLET Ø1"

DN65

GAS INLETRp 1"

Gas orifice flowmeter (included)Assembly by client

10

0 M

in.

(b)

44

10

0 M

in.

(b)

NOTES:

(a) Suitable onclient request

(b) by client

10

11

0

21

0

27

4

103,5

108

WA

LL T

HIC

KN

ES

S "

X"

Ø101,6

20

0 (a

)

24

0 (a

)

Nr.4 holes Ø14 (a)

Ø113

D3004I11

Page 22: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 22

EMB-3 LPG OVERALL DIMENSIONS

GAS INLET Ø 3/4"

Ø113

Gas orifice flowmeter (included)

Assembly by client

10

0 M

in.

(b)

44

10

0 M

in.

(b)

NOTES:

(a) Suitable oncustomer request

(b) by client

Premixing air inlet Rp 1/4"

10

11

0

21

0

32

6

104

108

Ø101,6

WA

LL T

HIC

KN

ES

S "

X"

14

0±5

20

0

24

0

Nr.4 holes Ø14

2437

GAS INLETRp 3/4"

AIR INLETDN65

D3004I12

Page 23: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 23

EMB-4-CH4 OVERALL DIMENSIONS

AIR INLETDN65

10

0 M

in (

b)

67

10

0 M

in.

(b)

Gas inlet Ø 1.1/2"

Gas orifice flowmeter (included)Assembly by client

NOTES:

(a) Suitable onclient request

(b) by client

10

11

0

21

8

27

9 W

AL

L T

HIC

KN

ES

S "

X"

20

0 (a

)

24

0 (a

)

104

119

Nr.4 holes Ø14 (a)

Ø129

Ø141

GAS INLETRp 1.1/2"

D3004I13

Page 24: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 24

EMB-4 LPG OVERALL DIMENSIONS

AIR

INLETDN65

Gas inlet Ø 1"

Gas orifice flowmeter (included)Assembly by customer

10

0 M

in.

(b)

44

10

0 M

in.

(b)

NOTES:

(a) Suitable oncustomer request

(b) by customer

20

0 (

a)

24

0 (

a)

Nr.4 holes Ø 14 (a)

24

Ø129

WA

LL T

HIC

KN

ES

S "

X"

101

10

,02

21

8

33

9104

130

14

0±5

37

Ø141

Premixing air inlet Rp 1/4"

GAS

INLETRp 1"

D3004I14

Page 25: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 25

EMB-5-CH4 OVERALL DIMENSIONS

X=

Wall

thic

kness

Ø129

Ø203

Nr.4 holes Ø14 on 235 D.B.C.

AR

Gas inletRp 1.1/2"

100 M

in (

a)

67

100 M

in.

(a)

Gas inlet Ø 1.1/2"

Gas orifice flowmeter (included)Assembly by customer

Air inletØ 4"

10

7

13

1137

26

8

126

135

Ø141 NOTES:

(a) by customer

D3004I15

Page 26: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 26

EMB-5 LPG OVERALL DIMENSIONS

Ø129

110421 ± 10

12292 4850

Premix air inlet Rp 1/2"

126

Ø141

Gas orifice flowmeter (included)Assembly by customer

Gas inlet Ø 1"

10

0 M

in.

(a)

44

10

0 M

in.

(a)

Gas inletRp 1"

AR

Ø203

Nr.4 holes Ø14 on 235 D.B.C.

Air inletDN100

83

13

11

37

35

1X

= W

all

thic

kn

ess

NOTES:

(a) by customer

D3004I16

Page 27: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 27

EMB-6-CH4 OVERALL DIMENSIONS

Gas inlet

RA

Ø 2

03

Rp 2"

Air inletDN150

Gas orifice flowmeter (included)

Assembly by customer

Gas inlet Ø 2"

10

0 M

in.

(a)

70

10

0 M

in.

(a)

Nr.4 holes Ø14 on 235 D.B.C.

Ø168

12

11

75

15

5

45

1X

= W

all

thic

kn

ess

156

186

NOTES:(a) by customer

Ø180

D3004I17

Page 28: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 28

EMB-6 LPG OVERALL DIMENSIONS

Gas inlet

RA

Ø 2

03

Rp 1.1/2"

Air inletDN150

Gas orifice flowmeter (included)Assembly by customer

Gas inlet Ø 1.1/2"

Nr.4 holes Ø14 on 235 D.B.C.

Ø168

17

51

55

X=

Wa

ll th

ickn

ess

156

1861

00

Min

. (a

)7

21

00

Min

. (a

)

1221204812092

501± 5

Premix airInlet Rp 1.1/2"

94

33

0

62

4

NOTES:(a) by customer

Ø180

D3004I18

Page 29: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 29

EMB-7-CH4 OVERALL DIMENSIONS

67 Min=100mm (b)

Gas orifice flowmeter (included)Assembly by client

NOTES:

(a) Suitable onclient request

(b) by client

Min=100mm (b)

WA

LL T

HIC

KN

ES

S "

X"

AIR INLETDN 150

GAS INLETDN50

Ø207

Rp

2"

Rp

2"

Nr. 4 holes Ø18

15

21

7

44

3

51

6

Ø195

Ø3

60

(a

)

Ø4

00

(a

)

D3004I19

Page 30: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 30

EMB-7 LPG OVERALL DIMENSIONS

Gas orifice flowmeter (included)Assembly by client

PREMIX

AIR INLET

Rp 1/2"

67 Min=100mm (b)

Rp

2"

Rp

2"

Min=100mm (b)

NOTES:(a) Suitable on

client request(b) by client

LPG INLETDN50

Ø3

60

(a

)

Ø4

00

(a

)

Nr.4 holes Ø18 (a)

15

21

7

44

4

54

059

2W

AL

L T

HIC

KN

ES

S "

X"

n195

226

169

422

AIR INLETDN 150

n207

D3004I20

Page 31: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 31

EMB-8-CH4 OVERALL DIMENSIONS

Gas orifice flowmeter (included)Assembly by client

AIR INLETDN 200

GAS INLETDN65

Ø7

6.1

Ø7

6.1

42 Min.=100mm (b)Min.=100mm (b)

NOTES:

(a) Suitable onclient request

(b) by client

Ø219,1

WA

LL T

HIC

KN

ES

S (

a)

15

21

7

44

351

6

169

226

Ø3

60

(a)

Nr.4 holes Ø18(a)

Ø231

Ø4

00

(a)

D3004I21

Page 32: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 32

EMB-8 LPG OVERALL DIMENSIONS

Gas orifice flowmeter (included)Assembly by customer

PREMIX

AIR INLET

Rp 1/2"

Ø231

AIR INLETDN 200

GAS INLETDN65

NOTES:

(a) Suitable oncustomer request

(b) by customer

Nr.4 holes Ø18 (a)

Ø4

00

(a)

15

21

6,9

4

44

4

54

059

2 W

AL

L T

HIC

KN

ES

S "

X"

169

226

422

Ø219,1

Ø7

6.1

Ø7

6.1

42 Min.=100mm (b)Min.=100mm (b)

Ø3

60

(a)

D3004I22

Page 33: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 33

EMB-9 CH4 OVERALL DIMENSIONS

Gas orifice flowmeter (included)Assembly by customer

Ø2

.1 2"

42Min.=100mmby customer

Min.=100mmby customer

NOTES:

(a) Suitable oncustomer request

(b) by customer

W

AL

L T

HIC

KN

ES

S =

"X

"

AIR

IN

LE

T

DN

25

0

201232

28

2

Ø256

Ø400

Ø370

53

961

6

45°

GA

S

INL

ET

DN

65

Ø270

Ø14x8

Ø2

.1 2"

D3004I24

Page 34: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB-9 GPL OVERALL DIMENSIONS

W

ALL T

HIC

KN

ES

S =

"X

"

AIR

IN

LE

T

DN

250

201

232

282

Ø256

Ø400

Ø370

5396

16

45°

GA

S

INLE

T

DN

65

Ø270

Ø14x8

G 1/2"

PREMIX

AIR INLET

422

Gas orifice flowmeter (included)Assembly by customer

Ø2.1 2"

42Min.=100mmby customer

Min.=100mmby customer

NOTES:

(a) Suitable oncustomer request

(b) by customer

Ø2.1 2"

D3400I26

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 34

Page 35: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 35

EMB-10 CH4 OVERALL DIMENSIONS

Gas orifice flowmeter (included)Assembly by customer

42MIN = 100mmBY CLIENT

MIN = 100mmBY CLIENT

NOTES:(a) Suitable on

customer request(b) by customer

Ø8

8.9

Ø8

8.9

WA

LL T

HIC

KN

ES

S =

"X

"

AIR

IN

LE

T

DN

25

0

201

262

28

2

Ø256

Ø460

Nr.8 holes Ø14Ø430

55

963

6

45°

GA

S

INL

ET

DN

80

Ø270

D3400I25

Page 36: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 36

EMB-10 GPL OVERALL DIMENSIONS

Gas orifice flowmeter (included)Assembly by customer

Ø88.9

Ø88.9

NOTES:(a) Suitable on

customer request(b) by customer

WA

LL T

HIC

KN

ES

S =

"X

"

AIR

IN

LE

T

DN

250

201

262

282

Ø256

Ø460

Ø430

5596

36

GA

S

INLE

T

DN

80

Ø270

Ø14x8

PREMIX

AIR INLET

G 1/2"

422

655

45°

42Min.=100mmby customer

Min.=100mmby customer

D3400I27

Page 37: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 37

EMB-6-BH OVERALL DIMENSIONS

184

358

15

50

350

UV-SCANNERG3/4" socket

Ø440

No.8 holes Ø18

425

Ø480

AIR INLETDN150

GAS INLETDN32/DN40

Ø3

80

FU

RN

AC

E H

OU

SIN

GH

OL

E Ø

39

2

CERAMIC FIBERBY ESA. DO NOTREMOVE!

D3004I23

Page 38: Free flame burners - esapyronics.com · and precaution norms. ¾To avoid the risks of burns or high voltage electrocu- ... Belarus and Kazakhstan). EMB - E3004 rev. 09 - 18/01/18

EMB - E3004 rev. 09 - 18/01/18

www.esapyronics.com 38

ORDERING CODE FOR COMPLETE BURNER

- --EMB- --

The codes marked with an asterisk (*) indentify the standards.

Notes:

1 Particular performance according to gas characteristics2 Standard version for free flame applications3 Version for applications with burner placed in open tube. Available up to version 4.4 Available in the 3,4,5 and 6 models (see "ignition and detection"paragraph).5 In open radiant tube applications.

Model

EMB-0EMB-1EMB-2... (see capacity table)

0

1

2

.....

Fuel

Natural gas

LPG

Poor gas (1)

CH4

GPL

GP

Gas adjuster

With gas adjusterWithout gas adjuster

GA*F

Type of flanging

According to ESA drawingAccording to Client's drawing

E*C

Ignition and detection

Ign. + det. ElectrodeMono electrodePilot burner (4)

E*MP

01

01 02 03 04 05 06

02

03

07

"X" flanged tube length

Indicate the length in mm (see overall dime-nions)

...

06

05

Flame length

Short flame (2)Long flame (3)

FC*FL (5)

04

-07