FS10-R30 Flame Detector Customer Product Manual Part 1609502-01 Issued 05/16 NORDSON CORPORATION AMHERST, OHIO USA For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative. This document is subject to change without notice. Check http://emanuals.nordson.com for the latest version and available local languages.

Upload: others

Post on 19-Sep-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector

Customer Product ManualPart 1609502-01

Issued 05/16

NORDSON CORPORATION AMHERST, OHIO USA

For parts and technical support, call the Industrial CoatingSystems Customer Support Center at (800) 433-9319 or

contact your local Nordson representative.This document is subject to change without notice.

Check http://emanuals.nordson.com for the latest versionand available local languages.

Page 2: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

Part 1609502-01 � 2016 Nordson Corporation

tents

Table of ContentsSafety 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Qualified Personnel 1. . . . . . . . . . . . . . . . . . . . . . . . .Intended Use 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Regulations and Approvals 1. . . . . . . . . . . . . . . . . .Personal Safety 2. . . . . . . . . . . . . . . . . . . . . . . . . . . .Fire Safety 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Grounding 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Action in the Event of a Malfunction 3. . . . . . . . . . .Disposal 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Description 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Flame Detection System Components 4. . . . . . . .Flame Detector Heads 5. . . . . . . . . . . . . . . . . . . . . . .Theory of Operation 6. . . . . . . . . . . . . . . . . . . . . . . . .

Flame Detection 6. . . . . . . . . . . . . . . . . . . . . . . . .Faults 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Specifications 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Detector Head Terminal Block Connections 6. .Electrical Power and Temperature Rating 6. . . .

Installation 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Mounting Equipment 7. . . . . . . . . . . . . . . . . . . . . . . .

Excel Booth Vestibule Mount 7. . . . . . . . . . . . . .Colormax Booth Mount 8. . . . . . . . . . . . . . . . . . .

Pneumatic Regulator Installation (if applicable) 9. .Flame Detector Head Connections 10. . . . . . . . . . . .Wiring Diagrams 12. . . . . . . . . . . . . . . . . . . . . . . . . . .

AC-Powered Control Panel 12. . . . . . . . . . . . . . . .AC-Powered Control Panel with Field Connector Box Wiring Diagram 13. . . . . . . . . . . .DC-Powered Control Panel 14. . . . . . . . . . . . . . . .DC-Powered Controls with Integration into System Control Panel 15. . . . . . . . . . . . . . . . . . . . .

Operation 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Through-the-Lens Test 16. . . . . . . . . . . . . . . . . . . . . .Test Light Procedure 16. . . . . . . . . . . . . . . . . . . . . . . .

Adjustment Procedure 17. . . . . . . . . . . . . . . . . . . .Detector Head Test Procedure 17. . . . . . . . . . . . .Test Light Maintenance 17. . . . . . . . . . . . . . . . . . .

Maintenance 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Daily 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Periodically 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Repair 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Microprocessor/Sensor Module Replacement 20. . .Parts 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Using the Illustrated Parts List 22. . . . . . . . . . . . . . .FS10-R30 Flame Detector Head 23. . . . . . . . . . . . . .

Universal Mounting Kit 23. . . . . . . . . . . . . . . . . . .Options 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Test Light 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Air Supply Parts 24. . . . . . . . . . . . . . . . . . . . . . . . .

Contact UsNordson Corporation welcomes requests for information, comments, andinquiries about its products. General information about Nordson can befound on the Internet using the following address:http://www.nordson.com.Address all correspondence to:

Nordson CorporationAttn: Customer Service555 Jackson StreetAmherst, OH 44001

NoticeThis is a Nordson Corporation publication which is protected by copyright.Original copyright date 2016. No part of this document may bephotocopied, reproduced, or translated to another language without theprior written consent of Nordson Corporation. The information containedin this publication is subject to change without notice.

Trademarks

Nordson and the Nordson logo are registered trademarks of NordsonCorporation.

All other trademarks are the property of their respective owners.

Page 3: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

Change Record i

Part 1609502-01� 2016 Nordson Corporation

Change RecordRevision Date Change

01 05/16 Release

Page 4: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

Change Recordii

Part 1609502-01 � 2016 Nordson Corporation

Page 5: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector 1

Part 1609502-01� 2016 Nordson Corporation

FS10-R30 Flame Detector

Safety Read and follow these safety instructions. Task- and equipment-specificwarnings, cautions, and instructions are included in equipmentdocumentation where appropriate.

Make sure all equipment documentation, including these instructions, isaccessible to all persons operating or servicing equipment.

Qualified Personnel Equipment owners are responsible for making sure that Nordson equipmentis installed, operated, and serviced by qualified personnel. Qualifiedpersonnel are those employees or contractors who are trained to safelyperform their assigned tasks. They are familiar with all relevant safety rulesand regulations and are physically capable of performing their assignedtasks.

Intended Use Use of Nordson equipment in ways other than those described in thedocumentation supplied with the equipment may result in injury to personsor damage to property.

Some examples of unintended use of equipment include

� using incompatible materials

� making unauthorized modifications

� removing or bypassing safety guards or interlocks

� using incompatible or damaged parts

� using unapproved auxiliary equipment

� operating equipment in excess of maximum ratings

Regulations and Approvals Make sure all equipment is rated and approved for the environment in whichit is used. Any approvals obtained for Nordson equipment will be voided ifinstructions for installation, operation, and service are not followed.

All phases of equipment installation must comply with all federal, state, andlocal codes.

Page 6: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector2

Part 1609502-01 � 2016 Nordson Corporation

Personal Safety To prevent injury, follow these instructions.

� Do not operate or service equipment unless you are qualified.

� Do not operate equipment unless safety guards, doors, or covers areintact and automatic interlocks are operating properly. Do not bypass ordisarm any safety devices.

� Keep clear of moving equipment. Before adjusting or servicing anymoving equipment, shut off the power supply and wait until theequipment comes to a complete stop. Lock out power and secure theequipment to prevent unexpected movement.

� Relieve (bleed off) hydraulic and pneumatic pressure before adjusting orservicing pressurized systems or components. Disconnect, lock out,and tag switches before servicing electrical equipment.

� Obtain and read Safety Data Sheets (SDS) for all materials used.Follow the manufacturer’s instructions for safe handling and use ofmaterials, and use recommended personal protection devices.

� To prevent injury, be aware of less-obvious dangers in the workplacethat often cannot be completely eliminated, such as hot surfaces, sharpedges, energized electrical circuits, and moving parts that cannot beenclosed or otherwise guarded for practical reasons.

Fire Safety To avoid a fire or explosion, follow these instructions.

� Do not smoke, weld, grind, or use open flames where flammablematerials are being used or stored.

� Provide adequate ventilation to prevent dangerous concentrations ofvolatile materials or vapors. Refer to local codes or your material SDSfor guidance.

� Do not disconnect live electrical circuits while working with flammablematerials. Shut off power at a disconnect switch first to preventsparking.

� Know where emergency stop buttons, shutoff valves, and fireextinguishers are located. If a fire starts in a spray booth, immediatelyshut off the spray system and exhaust fans.

� Clean, maintain, test, and repair equipment according to the instructionsin your equipment documentation.

� Use only replacement parts that are designed for use with originalequipment. Contact your Nordson representative for parts informationand advice.

Page 7: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector 3

Part 1609502-01� 2016 Nordson Corporation

Grounding

WARNING: Operating faulty electrostatic equipment is hazardous and cancause electrocution, fire, or explosion. Make resistance checks part of yourperiodic maintenance program. If you receive even a slight electrical shockor notice static sparking or arcing, shut down all electrical or electrostaticequipment immediately. Do not restart the equipment until the problem hasbeen identified and corrected.

Grounding inside and around the booth openings must comply with NFPArequirements for Class II Division 1 or 2 Hazardous Locations. Refer toNFPA 33, NFPA 70 (NEC articles 500, 502, and 516), and NFPA 77, latestconditions.

� All electrically conductive objects in the spray areas shall be electricallyconnected to ground with a resistance of not more than 1 megohm asmeasured with an instrument that applies at least 500 volts to the circuitbeing evaluated.

� Equipment to be grounded includes, but is not limited to, the floor of thespray area, operator platforms, hoppers, photoeye supports, andblow-off nozzles. Personnel working in the spray area must begrounded.

� There is a possible ignition potential from the charged human body.Personnel standing on a painted surface, such as an operator platform,or wearing non-conductive shoes, are not grounded. Personnel mustwear shoes with conductive soles or use a ground strap to maintain aconnection to ground when working with or around electrostaticequipment.

� Operators must maintain skin-to-handle contact between their hand andthe gun handle to prevent shocks while operating manual electrostaticspray guns. If gloves must be worn, cut away the palm or fingers, wearelectrically conductive gloves, or wear a grounding strap connected tothe gun handle or other true earth ground.

� Shut off electrostatic power supplies and ground gun electrodes beforemaking adjustments or cleaning powder spray guns.

� Connect all disconnected equipment, ground cables, and wires afterservicing equipment.

Action in the Event of a Malfunction If a system or any equipment in a system malfunctions, shut off the systemimmediately and perform the following steps:

� Disconnect and lock out electrical power. Close pneumatic shutoffvalves and relieve pressures.

� Identify the reason for the malfunction and correct it before restarting theequipment.

Disposal Dispose of equipment and materials used in operation and servicingaccording to local codes.

Page 8: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector4

Part 1609502-01 � 2016 Nordson Corporation

Description

Flame Detection System Components The flame detection system is installed in a coating system booth andinterfaces with the booth and the application system controls. The flamedetector shuts down the booth, application equipment, and the conveyorwhen it detects a flame in the booth.

See Figure 1. The flame detection system consists of one or two detectorheads and an indicator panel. The detector circuit is available as either a120/230 Vac, 24 Vdc, NEMA12 panel, or as a control board and operatorcontrols that can be integrated into a booth control panel.

NOTE: The field wiring connector adapter box connects to the AC controlpanel and is available as an option to primarily support XL-3000 legacysystems.

Control Panel, Flame Detection, 24 Vdc

Flame Detector Panel Integration Kit Field Wiring Connector Adapter Kit

Front View Side View

Flame Detector Head

Control Panel, Flame Detection, AC Power

Figure 1 Flame Detection System Components

Page 9: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector 5

Part 1609502-01� 2016 Nordson Corporation

Flame Detector HeadsSee Figure 2.

The detector heads simultaneously scan IR spectrum and the visiblespectrum. They use intelligent, real-time signal processing to tell thedifference between a real flame and false-alarm radiant energy sources.

Each detector head continuously monitors itself via a through-the-lens test.The detector head shines a light through the lens and looks for a reflectionfrom the reflective plate. If the test fails, the detector head goes into faultmode and the amber fault indicator lights.

Each detector head has a status LED, visible through the lens. Thedetector head lens is continuously cleaned by low-pressure air flowing fromthe air shield.

FS10-R30 MODEL

Figure 2 FS10-R30 Flame Detector Head

Page 10: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector6

Part 1609502-01 � 2016 Nordson Corporation

Theory of Operation

Flame DetectionIf a flame is detected inside the booth, interlock relays in the indicator panelopen and shut down the exhaust fan, application equipment, and conveyor.The red FLAME DETECTED indicator lights and the flame alarm sounds.

FaultsThe FAULT DETECTED indicator light and the fault alarm alert theoperators of problems with the detector heads. There are two fault modes:

Fault: A fault occurs when one detector head loses power, fails athrough-the-lens test, or has a microprocessor/sensor module malfunction.The fault indicator for that detector head lights and the fault alarm sounds.No interlocked equipment is shut down if two detector heads are used andonly one is in fault. If only one detector head is used, any fault is treated asa major fault.

Major Fault: A major fault occurs when both detector heads lose power, faila through-the-lens test, or have microprocessor/sensor malfunctions. Bothfault indicators light and the fault alarm sounds. If only one detector head isconnected, then any fault is a major fault. A major fault shuts down thebooth and application equipment. The conveyor will continue to run. Theconveyor is shut down only if a flame is detected.

Specifications

Detector Head Terminal Block Connections FS10-R30 Model Pin Function

1 DC Common

4 +24 Vdc

5 Fault Relay (N.O.)

6 Fault Relay (COM)

9 Fire Relay (N.O.)

10 Fire Relay (COM)

Electrical Power and Temperature RatingItem Specification

Detector Head Input Voltage 24 Vdc, 120 mA

Temperature Rating -40 �C to +75 �C, (-40 �F to +185 �F)

Page 11: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector 7

Part 1609502-01� 2016 Nordson Corporation

Installation WARNING: Allow only qualified personnel to perform the following tasks.Follow the safety instructions in this document and all other relateddocumentation.

Mounting Equipment

Excel Booth Vestibule Mount See Figure 3.

1. Measure and mark the locations in the booth entrance and exitvestibules (2) for the detector heads (1).

2. Mount one detector head to the floor of each vestibule diagonally asshown below, using the included brackets and screws, washers, lockwashers, and nuts.

NOTE: Mounting brackets will need to be oriented differently dependingon the detector head being used.

NOTE: Each detector head has a 90-degree cone-shaped field of view.

3. Align the detector head center lines (4) so they have an unobstructedview of the spray guns (3), conveyor (5), hangers, and workpieces (6).

4. Mount the indicator panel in an appropriate location, close to or on thebooth electrical panel, or on an operator platform, using the mountingholes on the panel flanges.

1

4 23

5

6

1

Figure 3 Flame Sensors and Light Test Source Excel Booth Installation Top View

1. Detector heads2. Booth vestibules

3. Spray guns4. Centerlines

5. Conveyor6. Hangers and workpieces

Page 12: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector8

Part 1609502-01 � 2016 Nordson Corporation

Colormax Booth Mount See Figure 4.

1. Measure and mark the locations at the top of the booth entrance (2) tomount the detector heads (1).

2. Mount the detector heads to the top corners of the booth entry wall asshown below. Orient the bracket appropriately using the includedbrackets and screws, washers, lock washers, and nuts.

NOTE: Mounting brackets will need to be oriented differently dependingon the detector head being used.

NOTE: Each detector head has a 90-degree cone-shaped field of view.

3. Align the detector head center lines (4) so they have an unobstructedview of the spray guns (3), conveyor (5), hangers, and workpieces (6).

4. Mount the indicator panel in an appropriate location, close to or on thebooth electrical panel, or on an operator platform, using the mountingholes on the panel flanges.

4

2

3

5

6

1

1

Figure 4 Flame Sensors and Light Test Source Colormax Booth Installation Top View

1. Detector heads2. Booth entrance

3. Spray guns4. Centerlines

5. Conveyor6. Hangers and workpieces

Page 13: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector 9

Part 1609502-01� 2016 Nordson Corporation

Pneumatic Regulator Installation (if applicable)See Figure 5.

Install a 1.0 bar (15 psi) fixed-pressure regulator for each detector head.

1. Install the regulator (4) on the booth as close as practical to the detectorhead (2).

2. Connect 6-mm air tubing (3) from the air supply to the regulator andfrom the regulator to the detector head air shield.

1 2

3

4

Figure 5 Detector Head Pneumatic Connections

1. Vestibule2. Detector head

3. 6-mm air tubing 4. Regulator

Page 14: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector10

Part 1609502-01 � 2016 Nordson Corporation

Flame Detector Head Connections

WARNING: All electrical connections must be made according to local ornational electrical codes. Use properly sized wire and approved conduitand fittings. Failure to observe this warning could result in property damageor personal injury.

NOTE: Use copper conductors for all field wiring to the indicator panel.

See Figure 6.

Connect the detector heads to the indicator panel with six-wire shieldedcable, ground wire, flexible or rigid conduit, and liquid-tight conduit fittings(Type 12 minimum rating).

1. Loosen the set screw (2) in the upper housing (1). Unscrew the upperhousing from the lower housing (6).

2. Loosen the three screws (4) in the top of the microprocessor/sensormodule (3). Remove the module from the lower housing (6). Keep thesensor lens clean.

3. Remove one of the plugs (8) from the lower housing (6).

4. Screw the bulkhead (12) on the liquid−tight conduit fitting (9) (Type 12minimum) and install in the open port.

5. Pull the cable (7) and ground wire (11) through the conduit (10), thenconnect the conduit (10) to the fitting (9).

6. Connect the cable wires to the terminal block (5) on the bottom of themicroprocessor/ sensor module. See Wiring Diagrams Figures 7, 8, 9,or 10 for connections.

7. Connect the ground wire to the green ground stud in the lower housing.

8. Install the microprocessor/sensor module (3) into the lower housing (6)and secure it in place with the three screws (4) removed in step 2.

9. Screw the upper housing (1) on the lower housing (6). Tighten the setscrew.

10. Refer to the appropriate system wiring diagram and connect the cablewires to the control panel as shown in Figures 7, 8, 9, or 10.

Page 15: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector 11

Part 1609502-01� 2016 Nordson Corporation

6

1

4

5

2

3

78

910

1111

12

Figure 6 Detector Head Electrical Connection

1. Upper housing2. Set screw3. Microprocessor/sensor module4. Screws

5. Terminal block6. Lower housing7. Cable8. Plug

9. Conduit fitting10. Conduit11. Ground wire12. Bulkhead

Page 16: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector12

Part 1609502-01 � 2016 Nordson Corporation

Wiring Diagrams NOTE: Connections must be made so that power is supplied to theindicator panel as long as the booth electrical power is turned on. Supplyservice must be provided from a disconnect switched source.

AC-Powered Control PanelMake connections according to Figure 7. Supply 120−240 Vac, 1 phase,50/60 Hz, 2 amp electrical service with ground to the indicator panel fromthe booth electrical panel. Use three-wire cable, flexible or rigid conduit,and liquid-tight conduit fittings.

NOTE: If a field wiring connector box is added, refer to Figure 8.

S/N

MADE IN USA

R1

+24VDC

PCA

1604

467

B

1 5 9

13

4 8 12

14

1 5 9

13

4 8 12

14

3

7

11

13

4

8

12

14

12

4

8

10

2

6

9

1

5

7 8 95 6431 2

56

73

42

18

910

123

56

73

42

15

67

34

21

LED1FU104

1.0A TD

1 5 9

13

4 8 12

14

1 5 9

13

4 8 12

14

NO

RD

SON

CR

105

CR

123

CR

109

CR

116

CR

120

JPW

R

JEXT

JDH

2JD

H1

JFP

+24VDC

DCCOM GND

PE

PCB

1604

466

BFL

AME

DET

ECTO

R

-V +V

L N

DC ON

ÎÎÎÎÎ

PWS102FUSES: 2A TD

S505R-2 or equal

L1 -

FU

101

L2 -

FU

102

- -

- -

- -

- -

PE/G

ND

1

2

3

4

5

6

7

JDH

1

1

2

3

4

5

6

7

8

9

JEXT

1

2

3

4

5

6

7

JDH

2

10

PE/GND10401200104010901060DCCOM

109

65

41

DET

ECTO

R H

EAD

#1

FLAM

E FAU

LTVD

C

PE/GND10401200104011601130DCCOM

109

65

41

DET

ECTO

R H

EAD

#2

FLAM

E FAU

LTVD

C

PE/GND

--

12531250

129112901292127112701272

BOO

THIN

T'LK

CO

NVE

YOR

INTE

RLO

CK

250V

AC 5

A M

AX

= O

K=

FLAM

E D

ET

1

4

5

6

9

10

BLKWHTREDGRNORGBLUSHIELD

BLKWHTREDGRNORGBLUSHIELD

BLK

WHT

RED

GRN

ORG

BLU

1

4

5

6

9

10

BLK

WHT

RED

GRN

ORG

BLU

PE12501253

127112701272

129112901292

GND

GND

GRN/YEL

120−240 VAC 1PH

50/60HZ 2A

INTERCONNECTLABEL

DETECTOR HEAD #2

DETECTOR HEAD #1

GREEN/YELLOWGROUND CABLE (TYP)

MULTICONDUCTOR CABLE (TYP)

MAY ALSO BETERMINATED FROMDETECTOR HEAD TOSYSTEM GROUNDBLOCK

CABLE OPTIONTRAY RATED

BLK

YEL

RED

BRN

ORG

BLU

GRN/YEL

GRN/YEL

FLAME SYSTEM INTERLOCK

(CUSTOMER USE)

BOOTH INTERLOCK

CONVEYOR INTERLOCK

Figure 7 Installation Wiring Diagram − Flame Detection Control Panel, AC Power, Indicator Panel

Page 17: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector 13

Part 1609502-01� 2016 Nordson Corporation

AC-Powered Control Panel with Field Connector BoxWiring Diagram

Make connections according to Figure 8.

BOOTHINTERLOCK

S/N

MADE IN USA

R1

+24VDC

PCA

1604

467

B

1 5 9

13

4 8 12

14

1 5 9

13

4 8 12

14

3

7

11

1314

12

4

8

10

2

6

9

1

5

7 8 95 6431 2

56

73

42

18

910

123

56

73

42

15

67

34

21

LED1

FU104

1.0A TD

1 5 9

13

4 8 12

14

1 5 9

13

4 8 12

14

NO

RD

SON

CR

105

CR

123

CR

109

CR

116

CR

120

JPW

R

JEXT

JDH

2JD

H1

JFP

+24

VDC

DC

COM GND

PE

PCB

1604

466

BFL

AME

DET

ECTO

R

-V +V

L N

DC ON

ÇÇÇÇÇÇÇÇÇÇ

PWS102FUSES: 2A TD

S505R-2 or equal

L1 -

FU

101

L2 -

FU

102

- -

- -

- -

- -

PE/G

ND

1

2

3

4

5

6

7

JDH

1

1

2

3

4

5

6

7

8

9

JEXT

1

2

3

4

5

6

7

JDH

2

10

PE/GND10401200104010901060DCCOM

10

9

6

5

4

1

DET

ECTO

R H

EAD

#1

FIR

EFA

ULT

VDC

PE/GND10401200104011601130DCCOM

10

9

6

5

4

1

DET

ECTO

R H

EAD

#2

FIR

EFA

ULT

VDC

PE/GND

--

12531250

129112901292127112701272

BOO

THIN

T'LK

CO

NVE

YOR

INTE

RLO

CK

250V

AC 5

A M

AX

= O

K=

FLAM

E D

ET

120VAC

1

4

5

6

9

10

WHT/BLKWHT/BRNWHT/REDWHT/ORGWHT/YELPURGRY

BLKBRNREDORGYELBLUGRN

BLK

WHT

RED

GRN

ORG

BLU

1

4

5

6

9

10

BLK

WHT

RED

GRN

ORG

BLU

PE12501253

127112701272

CONVEYORINTERLOCK

129112901292

FLAME SYS.INTERLOCK

(CUSTOMER USE)

INTERCONNECTLABEL

BLK

WH

T

RED

GR

N

OR

G

BLU

SHLD

1 2 3 4 5 6 SH

BLK

WH

T

RED

GR

N

OR

G

BLU

SHLD

1 2 3 4 5 6 PE1 2 3 4 5

DET HEAD #2DET HEAD #1CONNECTOR CONNECTOR CONNECTORBL

K

BRN

RED

OR

G

YEL

BLU

GR

N

WH

/BK

WH

/BR

WH

/RD

WH

/OR

WH

/YL

PUR

GR

Y

RED

WH

T

GR

N/Y

LW

GNDGRN/YEL

WH

TR

EDG

R/Y

WBL

KO

RG

GNDGRN/YEL

AC POWER120VAC 60HZ

(1)

(2)

(3)

(4)

(5)

L2/N

L1

GND

RLY CNT 1

RLY CNT 2

120V POWER

INPUT

BOOTH INTLK

CONTACT

GREEN/YELLOWGROUND CABLE (TYP)

MULTICONDUCTORCABLE (TYP)

DETECTOR HEAD #2

DETECTOR HEAD #1CABLE OPTIONTRAY RATED

BLK

YEL

RED

BRN

ORG

BLU

GRN/YEL

FIELD WIRINGCONNECTOR BOX

Figure 8 Installation Wiring Diagram − AC-Powered Control Panel with Field Connector Adapter Box

Page 18: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector14

Part 1609502-01 � 2016 Nordson Corporation

DC-Powered Control PanelMake connections according to Figure 9.

S/N

MADE IN USA

R1

+24VDC

PCA

1604

467

B

1 5 9

13

4 8 12

14

1 5 9

13

4 8 12

14

3

7

11

13

4

8

12

14

12

4

8

10

2

6

9

1

5

7 8 95 6431 2

56

73

42

18

910

123

56

73

42

15

67

34

21

LED1FU104

1.0A TD

1 5 9

13

4 8 12

14

1 5 9

13

4 8 12

14

NO

RD

SON

CR

105

CR

123

CR

109

CR

116

CR

120

JPW

R

JEXT

JDH

2JD

H1

JFP

+24VDC

DCCOM GND

PE

PCB

1604

466

BFL

AME

DET

ECTO

R

1234567

JDH

1

123456789

JEXT

1234567

JDH

2

10

PE/GND10401200104010901060DCCOM

109

65

41

DET

ECTO

R H

EAD

#1

FLAM

EFA

ULT

VDC

PE/GND10401200104011601130DCCOM

109

65

41

DET

ECTO

R H

EAD

#2

FLAM

EFA

ULT

VDC

PE/GND

--

12531250

129112901292127112701272

BOO

THIN

T'LK

CO

NVE

YOR

INTE

RLO

CK

250V

AC 5

A M

AX

= O

K=

FLAM

E D

ET

1

4

5

6

9

10

BLKWHTREDGRNORGBLUSHIELD

BLKWHTREDGRNORGBLUSHIELD

BLK

RED

WHT

GRN

ORG

BLU

1

4

5

6

9

10

BLK

RED

WHT

GRN

ORG

BLU

PE12501253

127112701272

129112901292

GND

GNDGRN/YEL

GRN/YEL

+24 C PE

CONVEYORINTERLOCK

FLAME SYSTEM INTERLOCK

BOOTH INTERLOCK

(CUSTOMER USE)

GREEN/YELLOWGROUND CABLE (TYP) MULTICONDUCTOR

CABLE (TYP)

DETECTOR HEAD #2

DETECTOR HEAD #1

INTERCONNECTLABEL

CABLE OPTIONTRAY RATED

BLK

YEL

RED

BRN

ORG

BLU

GRN/YEL

Figure 9 Installation Wiring Diagram − Flame Detection Control Panel, 24 Vdc, Indicator Panel

Page 19: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector 15

Part 1609502-01� 2016 Nordson Corporation

DC-Powered Controls with Integration into SystemControl PanelMake connections according to Figure 10.

924924

+24VDCMAIN 24V COM

10011001

+24VDCMAIN

24V COM

+24VDC

7 8 95 6431 2

56

73

42

18

910

123

56

73

42

15

67

34

21

FU104

1.0A TD

CR

105

CR

123

CR

109

CR

116

CR

120

JPW

R

JEXT

JDH

2JD

H1

JFP

+24VDC

DCCOM GND

PE

PCA 1604467 B

NORDSONFLAME DETECTOR

G

LT944

SS946

R

LT941

LT936

A

FLAME DETECTION SYS POWER

FLAME DETECTED

AUDIBLE ALARM

DETECTOR HEAD #2

ALB939

FAULT

DETECTOR HEAD #1FAULT

DETECTOR HD RESETDET 1 DET 2

X

X

DC COMMON

718

718BOOTH INTERLOCK

JEXT (2), JEXT (3)

CONVEYOR INTERLOCK A

JEXT(8) JEXT(7) JEXT(9)

CLOSED WHEN NORMAL

NORMAL STATE SHOWN

NO FAULTS

CONVEYOR INTERLOCK B

JEXT(5) JEXT(4) JEXT(6)

NORMAL STATE SHOWN

NO FAULTS

FLAME BOARD OUTPUTS

OPEN WHEN FAULT DETECTED

INTERLOCKCUSTOMER CONVEYOR

INTERLOCKBOOTH

7165

7167

9300

9290

FLAME DETECTOR #1

PE/GND

FIRE OUTPUT (2)FAULT OUTPUT (1)FAULT OUTPUT (2)VDCDC COM

FIRE OUTPUT (1)

SHIELDPE/GND

96541

10

FLAME DETECTOR #2

PE/GND

FIRE OUTPUT (2)FAULT OUTPUT (1)FAULT OUTPUT (2)VDCDC COM

FIRE OUTPUT (1)

SHIELDPE/GND

96541

10GRN/YEL

ORANGEGREEN

REDWHITEBLACK

BLUE

GRN/YEL

ORANGEGREEN

REDWHITEBLACK

BLUE

A

CABLE OPTIONTRAY RATED

BLK

YEL

RED

BRN

ORG

BLU

GRN/YEL

9291

LT938

Figure 10 Reference Drawing for Flame Detector Panel Kit − Integration into System Control Panel

Page 20: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector16

Part 1609502-01 � 2016 Nordson Corporation

Operation WARNING: Allow only qualified personnel to perform the following tasks.Follow the safety instructions in this document and all other relateddocumentation.

Through-the-Lens TestThe detector heads automatically perform periodic through-the-lens tests tocheck their operation. If a test fails, the detector head goes into fault mode.Refer to Troubleshooting for diagnostic and correction procedures.

Test Light Procedure The FS10-R30 test light has a light and lens combination that produces theappropriate IR source for testing the FS10 system. Refer to Parts for thetest light part number.

The test light has a three-position switch: Off, Continuous Beam, andPulsed Beam.

Figure 11 Test Light

Page 21: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector 17

Part 1609502-01� 2016 Nordson Corporation

Adjustment ProcedureNOTE: A moderately-dark room is best for this adjustment.

1. Switch the test light to Continuous Beam and direct the beam on a wallor other vertical surface.

2. Loosen or tighten the lens cap until the beam is at its smallest diameter.

Detector Head Test ProcedureNOTE: The response to the test light is slower than the ½-second responseof the detector head to the flame from a powder gun.

1. Switch the test light to Continuous Beam and direct the beam at adetector from a distance of 1.2−2.4 m (4−8 ft).

2. Wait for a response from the detector head and detector indicator panel.Response to the test light typically take several seconds or longer, up to15−20 seconds.

3. Reset the detector head with the Reset switch on the indicator panel.

Test Light MaintenanceTo replace the test light batteries, unscrew the threaded lens cap.

Page 22: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector18

Part 1609502-01 � 2016 Nordson Corporation

Maintenance WARNING: Allow only qualified personnel to perform the following tasks.Follow the safety instructions in this document and all other relateddocumentation.

WARNING: Keep the detector head lenses clean. Dirty lenses can preventthe detector heads from detecting a flame in the booth. Failure to observethis warning could result in property damage or personal injury.

NOTE: Keeping the lenses clean will prevent nuisance fault alarms orshutdowns. A dirty lens can cause a through-the-lens test to fail, triggeringa fault. If only one detector head is installed, a fault will shut down thecoating system during production.

DailyCheck the detector head lenses daily. If they are dirty, clean them with anapproved low-pressure air gun or an oil- and silicone-free cloth. Ifnecessary, dampen the cloth with ethyl alcohol. Do not use asilicone-based product such as commercial window cleaner to clean thedetector head lenses.

NOTE: If the detector head lenses are covered with powder overspray,check the air supply to the air shields. Air should be supplied at 1.0 bar(15 psi). Make sure the air shield orifices are not clogged.

PeriodicallyCheck all electrical connections periodically. Tighten any loose terminals.Replace any wiring that has worn or damaged insulation. Make sureconduit fittings are tight.

Page 23: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector 19

Part 1609502-01� 2016 Nordson Corporation

Troubleshooting WARNING: Allow only qualified personnel to perform the following tasks.Follow the safety instructions in this document and all other relateddocumentation.

WARNING: Hazardous voltages are present inside the indicator panelwhen booth power is on. Do not touch exposed terminals or wiring whenchecking voltages. Use insulated tools. Failure to observe could result insevere shock and personal injury.

These troubleshooting procedures cover only the most common problems.If you cannot solve a problem with the information given here, contact yourlocal Nordson representative for help.

Problem Possible Cause Corrective Action

Detector Fault Through-the- lens testfailed

If the red status LED on the detector head blinksthree times every 10 seconds, the detector lens isobstructed. Make sure the detector lens is cleanand clear of powder. If powder is accumulating onthe lenses, check the air supply to the air shields.Reset the detector head to clear the fault.

Detector head lostpower

Check the red status LED on the detector head.When operating normally, the LED should blinkonce every 10 seconds. If the LED is off, checkthe wiring between the indicator panel and thedetector. There should be 24 Vdc between pins 1and 4 at the detector.

� If 24 Vdc is present, replace themicroprocessor/sensor module.

� If 24 Vdc is not present, make sure greenPOWER ON indicator on the indicator panel islit.

If the indicator panel has power, repair or replacethe wiring between controller and detector.

Microprocessor/sensormodule failed

If the red status LED on the detector head blinksfive times every 10 seconds, there is a detectorover-temperature fault. Correct the condition andreset the detector head. If the faultcontinues, replace the detectormicroprocessor/sensor module.If the LED blinks four or six times every 10seconds, there is a detector internal hardware ormemory fault. Replace the detectormicroprocessor/sensor module.

Page 24: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector20

Part 1609502-01 � 2016 Nordson Corporation

Repair WARNING: Allow only qualified personnel to perform the following tasks.Follow the safety instructions in this document and all other relateddocumentation.

WARNING: Disconnect and lock out electrical power before servicing.

Microprocessor/Sensor Module ReplacementSee Figure 12.

1. Turn off power to the detector heads by turning off power to the system.

2. Disconnect the air tubing (2) from the air fittings (3). To avoid having toremove the detector head from the bracket, remove the air fittings fromthe air shield (1).

3. Loosen the set screw (4) in the upper housing (5), then unscrew theupper housing from the lower housing (10).

4. Loosen the three screws (6) in the top of the microprocessor/sensormodule (7). Remove the module from the lower housing. Keep thesensor lens clean.

5. Disconnect the cable wires from the module terminal block (8), andconnect the wires to the new module terminal block.

6. Install the module in the lower housing and secure it with the threescrews.

7. Check the O-ring (9) for damage and replace it if necessary.

8. Screw the upper housing onto the lower housing until tight. Tighten theset screw.

9. Wrap the air fitting threads with PTFE tape and install them in the airshield. Connect the air tubing to the quick-disconnect fitting.

Page 25: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector 21

Part 1609502-01� 2016 Nordson Corporation

21

3

5

7

8

10

4

6

9

Figure 12 Detector Head Electrical Connections

1. Air shield2. Air tubing3. Air fittings4. Set screw

5. Upper housing6. Screws7. Microprocessor/sensor module

8. Terminal block9. O-ring

10. Lowering housing

Page 26: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector22

Part 1609502-01 � 2016 Nordson Corporation

Parts To order parts, call the Nordson Industrial Coating Systems CustomerSupport Center at (800) 433-9319 or contact your local Nordsonrepresentative.

Using the Illustrated Parts List Numbers in the Item column correspond to numbers that identify parts inillustrations following each parts list. The code NS (not shown) indicatesthat a listed part is not illustrated. A dash (—) is used when the part numberapplies to all parts in the illustration.

The number in the Part column is the Nordson Corporation part number. Aseries of dashes in this column (−−−−−−) means the part cannot be orderedseparately.

The Description column gives the part name, as well as its dimensions andother characteristics when appropriate. Indentions show the relationshipsbetween assemblies, subassemblies, and parts.

� If you order the assembly, items 1 and 2 will be included.

� If you order item 1, item 2 will be included.

� If you order item 2, you will receive item 2 only.

The number in the Quantity column is the quantity required per unit,assembly, or subassembly. The code AR (As Required) is used if the partnumber is a bulk item ordered in quantities or if the quantity per assemblydepends on the product version or model.

Letters in the Note column refer to notes at the end of each parts list. Notescontain important information about usage and ordering. Special attentionshould be given to notes.

Item Part Description Quantity Note— 0000000 Assembly 11 000000 � Subassembly 2 A2 000000 � � Part 1

Page 27: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector 23

Part 1609502-01� 2016 Nordson Corporation

FS10-R30 Flame Detector HeadSee Figure 13 and the following parts list.

43

2

1

Figure 13 Detector Head Parts

Item Part Description Quantity Note1 327761 SHIELD, air, FS10-R30 12 1609503 DETECTOR, flame, FS10-R30 13 327758 � HOUSING, FS10-R30 14 327759 � MODULE, circuit board, FS10-R30 1

Universal Mounting Kit

Item Part Description Quantity Note− 1609232 KIT, mounting brackets, fire detector, UNI 1

Page 28: FS10-R30 Flame Detector Heademanuals.nordson.com/finishing/files/Powder/1609502.pdf · 2016. 9. 27. · FS10-R30 Flame Detector 3 2016 Nordson Corporation Part 1609502-01 Grounding

FS10-R30 Flame Detector24

Part 1609502-01 � 2016 Nordson Corporation

Options

Test LightThe test light is available for FS10-R30 flame detectors only See Figure 14and the following parts list.

Figure 14 Test Lamp

Part Description Note327762 LAMP, test, FS10-R30

Air Supply PartsSee the following parts list.

Part Description Note249467 REGULATOR, in-line air900730 TUBING, polyurethane, 0.250 x 0.040 in. A900742 TUBING, polyurethane, 6/4 mm, blue A

NOTE A: Order tubing in 1-foot increments.