fttx malaysia standard

49
Fiber to The x (FTTx) Malaysia Installation Standard [email protected] February 2013

Upload: sulaimqais

Post on 10-Jun-2015

2.228 views

Category:

Technology


7 download

DESCRIPTION

This slide include fttd,ftth,fttp,fttx,malaysia fiber optic standard,unifi

TRANSCRIPT

Page 1: FTTx Malaysia Standard

Fiber to The x (FTTx)Malaysia Installation Standard

[email protected] February 2013

Page 2: FTTx Malaysia Standard

Introduction

[email protected] February 2013

Page 3: FTTx Malaysia Standard

[email protected] February 2013

Overview FTTx

Page 4: FTTx Malaysia Standard

[email protected] February 2013

Malaysia is using single mode fiber with either 1310 nm or 1550 nm light signal depend on the distance. These lights are infrared light thus cannot be seen with naked eyes.

Fusion splicing process is used to permanently join two fiber end

Page 5: FTTx Malaysia Standard

TM [email protected] February 2013

All wireless adapter or device with standard (IEE802.11b/g/n) will work fine with wireless Residential Gateway (RG).

USB storage device can also be used as share storage. This can be done by connecting it to RG USB port .

For RG detail configuration settings refer this site http://netops.tm.com.my/netops2/misc/TMRND%20RG%20Installation%20Guide%20R1.2.pdf

Page 6: FTTx Malaysia Standard

TM [email protected] February 2013

Page 7: FTTx Malaysia Standard

[email protected] February 2013

Building classification

Page 8: FTTx Malaysia Standard

Single Dwelling Unit (SDU)

[email protected] February 2013

Page 9: FTTx Malaysia Standard

[email protected] February 2013

Page 10: FTTx Malaysia Standard

[email protected] February 2013

Indoor Fiber Cable Specification

• Bend Insensitive Fiber ≤ 15mm bending radius• Macro Bending Loss, Maximum loss at 1550nm shall be 0.25dB and at 1625nm shall be 1.0dB

• Attenuation coefficient :i) Maximum 0.35 dB/km – from 1310nm to 1625nm regions.ii) Maximum 0.4 dB/km in the 1383nm ±3nm region.iii) Maximum 0.3 dB/km in the 1550nm region

• tensile strength of the indoor cable shall be in excess of 80 N.

Page 11: FTTx Malaysia Standard

Fiber Termination Box (FTB)[email protected] February 2013

• FTB type approved by SIRIM• be suitable for 19” rack-mount and/or wall mounted• shall be complete with its respective mounting kits.• All edges shall be rounded• 1 SC/UPC (Standard Connector-Ultra Polish Connector)

All conduits or cable enclosure need to be completely concealed

Page 12: FTTx Malaysia Standard

[email protected] February 2013

Fiber Wall Socket (FWS)

provided by the developer with Standard Connector (SC) output connector Provided by the developer in all premises Must be placed at 0.3m above the floor level and 0.3m from the corner of the wall or from electrical points. made from the non-corrosive material or treated metallic material to resist corrosion placed adjacent to the electrical power socket. Recommend 2 AC power outlet min 1 near FWS 1 SC/UPC (Standard Connector-Ultra Polish Connector)

Page 13: FTTx Malaysia Standard

[email protected] February 2013

• trunking must be used to lay the cable between the FTB, located at the outside wall, and the FWS located inside the premise.• trunking bending radius must greater than 10 times of the trunking size• must be made from PVC or harder type of conduit with minimum 19mm diameter

Page 14: FTTx Malaysia Standard

[email protected] February 2013

• developer must provide manhole to the nearest NFP manhole before the NFP can lay their cable.• FTB to FWS total IL <1.5 (TM standard) , 1.52 (MCMC standard) dB

Page 15: FTTx Malaysia Standard

[email protected] February 2013

Pole Drop cable

Drop cable can be 1 or 2 core single mode fiber

• Drop Fibre generally must not exceed 50m

Page 16: FTTx Malaysia Standard

[email protected] February 2013

Page 17: FTTx Malaysia Standard

[email protected] February 2013

Underground Cable

• Drop Fibre must be connected to the premise wall FTB and at the other side it must be coiled inside the manhole and must be covered with end cap or terminate the fibre core inside the cable closure.• Drop Fibre generally must not exceed 50m

Page 18: FTTx Malaysia Standard

[email protected] February 2013

• FTB to FWS = IL <2.1 (TM Standard), 2.3 (MCMC standard) dB

Page 19: FTTx Malaysia Standard

[email protected] February 2013

Page 20: FTTx Malaysia Standard

[email protected] February 2013

Manhole

• Cover shall be made from fiber or any light material type which should be possible to be accessed by 1 person only• recommended size is JRC7 or JB30• be able to sustain up to 20 years

Page 21: FTTx Malaysia Standard

[email protected] February 2013

Page 22: FTTx Malaysia Standard

[email protected] February 2013

Underground duct-ways• required to connect the road side manhole to the Telecommunication Room (TR) inside the building or direct to the building• should be build to accommodate the local line for 20 years period in future expectation• material of the duct shall be PVC or harder and must be strong enough to protect the cable inside• duct diameter must be minimum of 50 mm• The duct routes must be as straight without sharp bends and not obstructed.• The maximum allowable bending radius is 20 times of duct diameter.• shall ensure that the constructed ducting system has a minimal risk from the nature disaster including flood• duct sectional length (manhole centre to manhole centre distance) of 180m to 220m

Page 23: FTTx Malaysia Standard

[email protected] February 2013

• This design is applicable if the depth of the drain is less than 450mm (1.5 feet)• small pit with minimum size 300mm X 300 mm X 300mm shall be prepared for easy access during the maintenance work

Page 24: FTTx Malaysia Standard

[email protected] February 2013

• depth of the drain is more than 450mm (1.5feet)• the duct must be protected by minimum 100mm of GI pipe to cover the duct from broken

Page 25: FTTx Malaysia Standard

[email protected] February 2013

• meet ITU G.657A

Page 26: FTTx Malaysia Standard

Other SDU

[email protected] February 2013

Page 27: FTTx Malaysia Standard

[email protected] February 2013

Other SDU exampleShop lot

Page 28: FTTx Malaysia Standard

[email protected] February 2013

Developer must provide a space minimum 600mm x 600mm beside FTB

Page 29: FTTx Malaysia Standard

[email protected] February 2013

Internal cable for building

• Single-Mode and meets specification ITU-T G.657A

Internal Fibre cable is used for corridor and indoor cabling

Page 30: FTTx Malaysia Standard

Multi Dwelling Unit (MDU)

[email protected] February 2013

Page 31: FTTx Malaysia Standard

[email protected] February 2013

MDU buildingCabling for MDU consist of 4 elements as below:a. Campus backbone cablingb. Building backbone-vertical cablec. Building horizontal cabled. Telecommunication outlet cabling.

Page 32: FTTx Malaysia Standard

[email protected] February 2013

Page 33: FTTx Malaysia Standard

[email protected] February 2013

• Number of effective core for each premise is two cores for business building and one core for residential building. • highly recommended to have minimum 30% spare cores for business and 10% of spare core for residential building.

•internal cabling must be tested and the result must be submitted to the NFP during the cabling approval process.

•All the cable must be tested from point to point for every termination.

•All the internal cabling for MDU must have a code or naming convention and tagged properly for easier maintenance and connection with NFP’s cable. All tag must be stated clearly and sealed with transparent material for easy to read.

•All cables need to be inventoried and one copy of inventory information must be submitted to the NFP during the cabling approval process

•Main hole at the road side until duct way into the building shall be provided by building owner

Page 34: FTTx Malaysia Standard

[email protected] February 2013

code or naming convention for the Internal Vertical Cable must follow standard as shown :

Page 35: FTTx Malaysia Standard

[email protected] February 2013

Horizontal cable

The internal horizontal cable must be covered eithera. Through ductingb. Concealed inside the wallc. Concealed underground floorc. using conduit through the ceiling

horizontal cable is referred to the cabling between Floor Riser FTB to FWS inside each individualunit premise

Page 36: FTTx Malaysia Standard

[email protected] February 2013

Network boundary 1 - Network Boundary between the NFP’s and the building management Network boundary 2 - Network Boundary between the building management and the individual customers

Page 37: FTTx Malaysia Standard

[email protected] February 2013

Page 38: FTTx Malaysia Standard

[email protected] February 2013

Riser Specification

Page 39: FTTx Malaysia Standard

[email protected] February 2013

Page 40: FTTx Malaysia Standard

[email protected] February 2013

Page 41: FTTx Malaysia Standard

[email protected] February 2013

• campus backbone cable and Internal Vertical Cable are normally same• Cable type must be loose tube or ribbon single mode fibres with features comply with G.652D or G.657A specification

Page 42: FTTx Malaysia Standard

[email protected] February 2013

Internal Horizontal Cable typically follows the specifications defined for distribution fibre and the type must single-mode fibre.

Page 43: FTTx Malaysia Standard
Page 44: FTTx Malaysia Standard

[email protected] February 2013

manhole, with minimum specification of JC9C size with 4 duct ways for connection to the nearest NFP’s manhole

Page 45: FTTx Malaysia Standard

[email protected] February 2013

Cable trench

Page 46: FTTx Malaysia Standard

[email protected] February 2013

Telecommunication room house the service provider equipment and cable

Page 47: FTTx Malaysia Standard

[email protected] February 2013

Page 48: FTTx Malaysia Standard

[email protected] February 2013

• shall be provided with electrical AC supply from the utility supplies at a nominal of 415 V, 3 phase, 4 wires, 50 Hz system or at a nominal voltage of 240V AC Single-Phase system with solidly earth system.

• shall be equipped with a 20A TPN metal clad Distribution Box (DB) of 20A• shall be equipped with daylight type fluorescent lighting that can provide a minimum of 300 Lux luminance at floor level.• FTB must be located at the right most position as this is the nearest point leading to the internal riser NFP’s network elements will be located adjacent to the FTB

Page 49: FTTx Malaysia Standard

[email protected] February 2013

Insertion Loss (IL) FTB inside Telecommunication room, to FWS inside each individual premise must not exceed 2.2 dB.