Setup Guide Setup Guide FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems P3AM-7852-06ENZ0 An installation space and network environment must be prepared in advance. Prepare the following manuals: Manuals for the ETERNUS DX100 S3/DX200 S3 Related manuals, such as manuals for the server or the networking equipment that is used Installation Space Site Planning Guide Network Environment Configuration Guide (Basic) Configuration Guide (Web GUI) Preparation STEP Installation space Check that the installation area meets the space requirements of the rack in which the ETERNUS DX is to be installed. Environmental considerations for installation Check if the installation area for the ETERNUS DX meets the environmental conditions and installation environment conditions. Power outlets Check the type and the number of power outlets/sockets that are required to install the ETERNUS DX. Completing and attaching the Network Settings label Write down the IP address for the ETERNUS DX on the Network Settings label and attach it inside the rack. Settings for the PC Set up the network environment - IP address : 192.168.1.2 - Subnet mask : 255.255.255.0 Set the Web browser Refer to "Configuration Guide (Web GUI)" for details on the settings that are required.

Upload: dinhcong

Post on 28-Jun-2018

255 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid … · 2017-05-09 · Setup GuideSetup Guide FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems P3AM-7852-06ENZ0 An

Setup GuideSetup Guide

FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems

P3AM-7852-06ENZ0

An installation space and network environment must be prepared in advance.

Prepare the following manuals: ● Manuals for the ETERNUS DX100 S3/DX200 S3 ● Related manuals, such as manuals for the server or the networking equipment that is used

Installation SpaceSite Planning Guide

Network Environment • Configuration Guide (Basic) • Configuration Guide (Web GUI)

Preparation STEP

Installation spaceCheck that the installation area meets the space requirements of the rack in which the ETERNUS DX is to be installed.

Environmental considerations for installationCheck if the installation area for the ETERNUS DX meets the environmental conditions and installation environment conditions.

Power outletsCheck the type and the number of power outlets/sockets that are required to install the ETERNUS DX.

Completing and attaching the Network Settings labelWrite down the IP address for the ETERNUS DX on the Network Settings label and attach it inside the rack.

Settings for the PC

● Set up the network environment

- IP address : 192.168.1.2 - Subnet mask : 255.255.255.0

● Set the Web browserRefer to "Configuration Guide (Web GUI)" for details on the settings that are required.

Page 2: FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid … · 2017-05-09 · Setup GuideSetup Guide FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems P3AM-7852-06ENZ0 An

2 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide

Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0

The rack rail needs to be attached to the rack and the controller enclosure or the drive enclosure needs to be installed.

Installation in a Rack STEP

Configuration Guide (Basic)

Controller Enclosures and Drive Enclosures (2.5" type/3.5" type)

●Drive enclosures must be installed above the controller enclosure. When installing multiple drive enclosures, install them in the order of the "DE_No. label" numbers that are attached to the drive enclosures. The DE_No. labels are attached on the locations that are shown in the figure on the right.

●The center of gravity must be taken into consideration to prevent a rack from toppling over. The controller enclosure and drive enclosures should generally be installed from bottom to top to lower the center of gravity and to ensure the safe use of racks.

IMPORTANT

DE_No. labels

DE_No. labels

Right front side of the drive enclosure (2.5” type/3.5” type)

Upper rear side of the drive enclosure (2.5” type/3.5” type)

Right front side of the high-density drive enclosure

Upper rear side of the high-density drive enclosure

1. Attach the rack rails to the rack. The size of the controller enclosure and each drive enclosure is 2U.

(Front rack pillars)

(Rear rack pillars)

Rack rail (for right side)

Rack rail (for left side)

Washers

M5 screws

M5 screws

Washers

M5 screws

Plate

M5 screws

Plate

Page 3: FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid … · 2017-05-09 · Setup GuideSetup Guide FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems P3AM-7852-06ENZ0 An

3 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide

Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0

M5 screws

M5 screws

Flange cover

Flange cover

● To fasten the controller enclosureUse three M5 screws to fasten the controller enclosure to the rack pillars and attach the flange cover.

● To fasten the drive enclosureUse four M5 screws to fasten the drive enclosure to the rack pillars and attach the flange cover.

M5 screws

Flange cover

M5 screws

Flange cover

2. Install and fasten the controller enclosure or the drive enclosure in the rack.

Make sure to install or remove the controller enclosure or the drive enclosure in the rack with two or more people.

IMPORTANT

Page 4: FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid … · 2017-05-09 · Setup GuideSetup Guide FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems P3AM-7852-06ENZ0 An

4 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide

Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0

High-density Drive Enclosures

1. Attach the rack rails to the rack.The size of a high-density drive enclosure is 4U.

2. Install the stopper brackets (for the left and right sides) in the front, and then install the flap brackets in the rear.

● Rack pillar: front ● Rack pillar: rear

Stopper bracket(left)

(Rack pillar: front)

Rack rail(right)

Rack rail(left)

M5 screw

M5 screw

Stopper bracket(right)

M4 screw

(Rack pillar: rear)

Rack rail(left)

Rack rail(right)

Flap bracket A

Flap bracket B

Page 5: FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid … · 2017-05-09 · Setup GuideSetup Guide FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems P3AM-7852-06ENZ0 An

5 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide

Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0

Various cables need to be connected to the ports on the rear of the ETERNUS DX.

Cable Connection STEP

●To help with cable management and prevent incorrect connection, attach labels to the cables and make a note of connection origins and destinations. ●This step describes dual controller type as an example. Note that there is only controller 0 (CM#0) for single controller type.

Point

●The cables should never be bent, twisted or pulled. ●Some cables have static-sensitive electronic components. Wear an anti-static wrist strap or touch a metal part to discharge the static electricity on your body before starting each operation. Failure to discharge static electricity before touching the connectors may cause a device failure.

IMPORTANT

Configuration Guide (Basic)

3. Install and fasten the high-density drive enclosure in the rack, and then attach the front cover.Attach the cable management arm in the rear.

For safety and stability, use a lifter to install or remove high-density drive enclosures in the rack.IMPORTANT

Front cover

(Rack pillar: front)

(Rack pillar: rear)

M5 screws

M5 screws

Cable management arm

Pin

Page 6: FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid … · 2017-05-09 · Setup GuideSetup Guide FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems P3AM-7852-06ENZ0 An

6 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide

Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0

● FC, iSCSI 10Gbit/s (10GBASE-SR), FCoE, Ethernet 10Gbit/s (for FC cable connection)

● iSCSI 10Gbit/s (10GBASE-T), iSCSI 1Gbit/s, Ethernet 1Gbit/s

● SAS

Connect a Host Interface cable to each of these ports.

Rear viewCable

● iSCSI 10Gbit/s (10GBASE-SR), FCoE, Ethernet 10Gbit/s (for Copper Twinax cable connection)

Controller enclosure

CA#0 CA#1 CA#0 CA#1

iSCSI 10Gbit/s (10GBASE-T), iSCSI 1Gbit/s

Port#0 Port#1

SAS

Port#0 Port#1

Port#0 Port#1

FC, iSCSI 10Gbit/s (10GBASE-SR), FCoE, Ethernet 10Gbit/s (for FC cable connection)

Port#0 Port#1

iSCSI 10Gbit/s (10GBASE-SR), FCoE, Ethernet 10Gbit/s (for Copper Twinax cable connection)

Ethernet 1Gbit/s

Port#0 Port#1 Port#2 Port#3

Host Interface Cable2

CA#1 CA#0 CA#1 CA#0

Controller enclosure

Rear viewCable

● MNT portA port that is used to connect to an operation management LAN. Before connecting to the operation management LAN, change the IP address of the MNT port in the Setup Network Environment settings.

● RMT portA port that is used for initial setup or to connect to the remote support center.

Controller (CM#0) Controller (CM#1)

MNT port MNT port

Controller enclosure

RMT port RMT port

LAN Cable1

Page 7: FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid … · 2017-05-09 · Setup GuideSetup Guide FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems P3AM-7852-06ENZ0 An

7 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide

Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0

DI (OUT) portDI (IN) port

● DI (OUT) side plug

● DI (IN) side plug

Rear viewCable

Attach the destination labels to the plugs of the mini SAS HD cables between enclosures.

When drive enclosures are installed, use mini SAS HD cables between enclosures to connect between the DI ports of each enclosure.

● Controller enclosure

● Drive enclosure

● Example of mini SAS HD cable connections between enclosures(when two drive enclosures are installed)Between Controller 0 and I/O module line 0, connect the drive enclosures in ascending order of the drive enclosure numbers.Between Controller 1 and I/O module line 1, connect the drive enclosures in descending order of the drive enclosure numbers.

The DI (IN) port is on the left side and the DI (OUT) port is on

the right side of each I/O module.

Plug the connectors on which the " " symbol is printed into

the DI (IN) ports.

Plug the connectors on which the " " symbol is printed into

the DI (OUT) ports.

The " ■ " symbol isprinted here.

The "●" symbol isprinted here.

DI (OUT) port

The controller enclosure only has DI (OUT) ports.

Connect the connectors on which the " " symbol is printed.

Controller enclosure

Drive enclosure 2

Drive enclosure 1

Mini SAS HD Cable Between Enclosures3

When connecting the mini SAS HD cable between enclosures, check the direction of the connector (the tab must be pointed downward) and firmly insert all the way in.

IMPORTANT

Tab

Page 8: FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid … · 2017-05-09 · Setup GuideSetup Guide FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems P3AM-7852-06ENZ0 An

8 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide

Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0

Connect the power cords to the inlets of the power supply unit.Use release ties to hold the power cords in place.

Rear viewCable

Drive enclosure

Controller enclosure

Power Cords4

Use ETERNUS Web GUI to perform a basic setup of the ETERNUS DX.

Connect a PC terminal to the ETERNUS DX.Connect the PC terminal to the RMT port of Controller 0 (CM#0) on the controller enclosure directly with the LAN cable.

Turn on the PC terminal and the ETERNUS DX.

PC terminal

LAN cable

LAN port

Controller enclosure

RMT port of Controller 0 (CM #0)

Basic Setup STEP

Configuration Guide (Basic)

Controller enclosure

Power switch

Drive enclosure

ETERNUS DX and PC Terminal Connection1

Powering On2

Page 9: FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid … · 2017-05-09 · Setup GuideSetup Guide FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems P3AM-7852-06ENZ0 An

9 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide

Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0

Perform the settings that are required before operation of the ETERNUS DX on the Initial Setup screen.

Perform the following settings according to the wizard screen:

● Set Storage System Name ● Change User Password ● Set Thin Provisioning ● Register SED Authentication Key ● Setup Network Environment

In the Setup Network Environment settings, set the IP address of the MNT port to connect the ETERNUS DX to the operation management LAN.

1. Open the Web browser on the PC terminal.

2. Enter the following URL in the address bar of the Web browser. http://192.168.1.1/The login screen for ETERNUS Web GUI appears.

3. To change the user interface language, click the [Option] button and select "English" or "Japanese" in "Language".

4. Enter the username and password.Username: rootPassword: root (by default)

ETERNUS Web GUI Startup3

Initial Setup4

After logging in, the Initial Setup screen of ETERNUS Web GUI appears.

After the settings are complete, close the Web browser.

Make sure to set up the network environment for the MNT port.If the network environment for the MNT port is not set up, some functions will be unusable.

IMPORTANT

Page 10: FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid … · 2017-05-09 · Setup GuideSetup Guide FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems P3AM-7852-06ENZ0 An

10 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide

Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0

Remove the LAN cable between the RMT port on Controller 0 and the PC terminal.Connect the LAN cables of the MNT ports on Controller 0 and Controller 1 to the network of the customer.Then start the web browser from the PC terminal that is connected to the network and log in to ETERNUS Web GUI again with the IP address that is set in the Setup Network Environment settings. After login, the Overview screen appears.

Establishing a Connection between the ETERNUS DX and the Operation Management LAN5

Set the firewall for each service.

Firewall Settings6

1. Click the [System] tab, click [Network] in [Category], and then click [Setup Firewall] in [Action].

2. Enable or disable each service.

If the network environment for the MNT port is not set up, some functions will be unusable. Make sure to set up the network environment.

IMPORTANT

Page 11: FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid … · 2017-05-09 · Setup GuideSetup Guide FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems P3AM-7852-06ENZ0 An

11 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide

Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0

Use ETERNUS Web GUI to set RAID configurations in the ETERNUS DX.

Perform the following settings: ● RAID group creation ● Volume creation ● Hot spare registration

1. RAID group creationCreate RAID groups to create volumes.To display the screen to create RAID groups:Click the [RAID Group] tab, and then click [Create] in [Action].

2. Volume creationCreate volumes in the RAID group.To display the screen to create volumes:Click the [Volume] tab, and then click [Create] in [Action].

3. Hot spare registrationRegister the hot spare for the failure of a drive.To display the screen to register the hot spare: Click the [Component] tab, and then click [Drives] in [Category].

● Global Hot Spare registrationSelect the drive that is to be registered as the Global Hot Spare and click [Assign Global HS] in [Action]. In the confirmation screen that appears, click the [OK] button.

● Dedicated Hot Spare registrationSelect the drive that is to be registered as the Dedicated Hot Spare and click [Assign Dedicated HS] in [Action].

RAID Configuration Settings7

Select which RAID group to use the selected drive as a Dedicated Hot Spare for and click the [Assign] button. In the confirmation screen that appears, click the [OK] button.

Page 12: FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid … · 2017-05-09 · Setup GuideSetup Guide FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems P3AM-7852-06ENZ0 An

12 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide

Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0

The host affinity settings ensure security when multiple servers are connected by assigning the host interface ports that the hosts (servers) can access and the volumes that the hosts (servers) can recognize.

Follow the procedure below to set host affinity by associating a host group, a CA port group and a LUN group.

1. Host group additionAdd the information on the hosts (servers) that access the ETERNUS DX.To display the screen to add the host groups (example for iSCSI host groups):Click the [Connectivity] tab, click [Host Group] in [Category], and then click [Add iSCSI Host Group] in [Action].

2. Port parameter settings

Set the connection information between the host interface port and the server. To display the screen to set the port parameters (example for iSCSI Port):Click the [Connectivity] tab, and then click [iSCSI] under [Port Group] in [Category]. Select the checkbox for the iSCSI port to set the port parameters for on the [iSCSI Port] screen and then click [Configure iSCSI Port] in [Action].

3. Port group creation

Create a port group for a host to access the ETERNUS DX. To display the screen to create a port group (example for iSCSI Port):Click the [Connectivity] tab, click [Port Group] in [Category], and then click [Create iSCSI Port Group] in [Action].

4. LUN group addition

Add a group of volumes that can be recognized by the host (LUN group).To display the screen to add a LUN group:Click the [Connectivity] tab, click [LUN Group] in [Category], and then click [Add LUN Group] in [Action].

Host Affinity Settings8

Page 13: FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid … · 2017-05-09 · Setup GuideSetup Guide FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems P3AM-7852-06ENZ0 An

13 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide

Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0

5. Host affinity creationCreate an association between a host group and a port group and an association between a host group and a LUN group.To display the screen to create a host affinity:Click the [Connectivity] tab, and then click [Create Host Affinity] in [Action].

Perform the ETERNUS DX monitoring setup if required. ● Notification of the ETERNUS DX problems as they occur is possible if the event notification method and level

have been set. ● If remote support is required, the ETERNUS DX needs to be set to notify the remote support center of failures.

Perform the settings required to connect to the server and install the required drivers. Perform the settings required for network devices connecting the server and the ETERNUS DX.After the server connection setup, confirm that the volumes in the ETERNUS DX can be recognized by the server.

All necessary settings are complete, and the ETERNUS DX is now ready for normal operation.

Monitoring Setup STEP

Server Connection STEP

Remote support allows prompt detection and resolution of trouble.Point

Configuration Guide (Basic)

• Configuration Guide (Basic) • Configuration Guide -Server Connection-

Page 14: FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid … · 2017-05-09 · Setup GuideSetup Guide FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems P3AM-7852-06ENZ0 An

14 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide

Copyright 2017 FUJITSU LIMITED P3AM-7852-06ENZ0

• The content of this manual is subject to change without notice. • This manual was prepared with the utmost attention to detail.

However, Fujitsu shall assume no responsibility for any operational problems as the result of errors, omissions, or the use of information in this manual.

• Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual.

• The content of this manual may not be reproduced or distributed in part or in its entirety without prior permission from Fujitsu.

FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage SystemsSetup Guide

P3AM-7852-06ENZ0Date of issuance: April 2017

Issuance responsibility: FUJITSU LIMITED

Operation and Maintenance Status checkThe status of the ETERNUS DX should be regularly monitored by checking the LEDs and using ETERNUS Web GUI.

Data backupImportant data should be regularly backed up to a tape drive or similar device as a precaution against system failures.

Maintenance support periodThe standard maintenance support period for ETERNUS DX is five years from the date of purchase, or is defined in your service level agreement (SLA). Contact your sales representative for details if you prefer to extend the period.

Operation Guide (Basic)