Proposed Materials Key
Textured Buff BrickworkSome areas Recessed 25mm from main face.Type:NBS:
2 Smooth Buff BrickworkNo Recessed Areas.Type: TBCNBS: TBC
3 External Render SystemSystem: TBCColour: Dark GreyNBS: TBC
4 External Render SystemSystem: TBCColour: Light GreyNBS: TBC
5 PPC Aluminium Parapet Coping SystemColour: Dark Grey, MattNBS: TBC
6 PPC Double Glazed Aluminium Window System,with Louvred Panel / Spandrel Panel as shown.Colour: Dark Grey, MattNBS: TBC
7
PPC Double Glazed Aluminium Door System,with Louvred Panel / Spandrel Panel as shown.Colour: Dark Grey, MattNBS: TBC
8
PPC Aluminium Louvred Door System,Colour: Dark Grey, MattNBS: TBC
9
PPC Aluminium Louvred Panel,Colour: Dark Grey, MattNBS: TBC
10
PPC Aluminium External Rainwater Pipe System,Square Section.Colour: Dark Grey, MattNBS: TBC
11
PPC Aluminium External Rainwater Hopper System,Colour: Dark Grey, MattNBS: TBC
12
Proposed Sprinkler Tank Enclosure, Hit & Miss Timber Fencing,Colour: TBCNBS: TBC
14
PPC Double Glazed Aluminium Window System,Colour: Dark Grey, MattNBS: TBC
NOTES:Fencing and trees not shown for purposes of building clarity, see site plan and landscape architects information for details.
All door restraint hoops to be specified by the landscape architect.
For further details on the brickwork detailing and areas of recessed brickwork, please refer to drawing 31791-DBS-06-ZZ-DR-A-2500.
Steel and Glass Canopy System, Proprietary System (TBC),Colour: TBCNBS: TBC
13
0000 - Ground Floor
3900010 - First Floor
7970020 - Roof
9075030 - Parapet
1 6 5 4 8 2 13 91 2 65 4 16 8
9099
mm
29128 mm
13 14
0000 - Ground Floor
3900010 - First Floor
7970020 - Roof
9075030 - Parapet
541
9099
mm
3 7 5
9249
mm
29128 mm
6 2 8 64 1 3 75131314
0000 - Ground Floor
3900010 - First Floor
7970020 - Roof
9075030 - Parapet
138635113 1 4 5212
19678 mm
9225
mm
9075
mm
14
0000 - Ground Floor
3900010 - First Floor
7970020 - Roof
9075030 - Parapet
13 13 6 3 5 1 13145 2 12
19678 mm
9225
mm
9075
mm
BLOCK 04
BLOCK 02
BLOCK 05
KEY PLAN (NTS)
N
E04
BLOCK 03
BLOCK 01
BLOCK 06
E01
E03
E02
1:1250
1:100
1:200
1000 3000 5000
1:500 5 15 25
10 30 50 70
M
mm
mm
M
5000 8000
Drawing Number
Original Size
Date
Scale
Drawn Checked Approved
© Kier Business Services Limited
A1RIBA 2013 Stage
Status
Revision
NOTES
Drawing Title
Project Name
Internal Project Number
Issuing Office Telephone
Version Drawn & Date
Checked & Date
Approved & DateAmendment
Client
Project Code Origin Volume Level Type Role Number
Scale:
This Document has been prepared by Kier Business Services Limited and no individual is personally liable in connection with the preparation of this Document. By receiving this Document and acting on it, the client or any other person accepts that no individual is personally liable whether in contract, tort, for breach of statutory duty or otherwise Kier Business Services Limited has used reasonable endeavours to provide information that is correct and accurate and the Document sets out reasonable conclusions that have been reached on the basis of the information available.
© Crown copyright and database rights 2017 Ordnance Survey 0100056811. You are permitted to use this data solely to enable you to respond to, or interact with, the organisation that provided you with the data. You are not permitted to copy, sub-licence, distribute or sell any of this data to third parties in any form.
1 : 100
AB NR LC02/03/2021
P02
Stage 03
S3
Proposed Elevations - Block 06
31791
Spalding Priory SEND Expansion
Lincoln
Willmott Dixon
31791-DBS-ZZ-XX-DR-A-1360
This Document is presented to Willmott Dixon in respect of the Spalding Priory SENDExpansionand may not be used or relied on by any other person or by the client inrelation to any other matters not covered specifically by the scope of this Document
Notwithstanding anything to the contrary contained in the Document, Kier BusinessServices Limited is obliged to exercise reasonable skill, care and diligence in theperformance of the services required by Willmott Dixonand Kier Business ServicesLimited shall not be liable except to the extent that it has failed to exercise reasonableskill, care and diligence, and this Document shall be read and construed accordingly.
P01 First Issue AB02/03/21
NR02/03/21
LC02/03/21
P02 Material type 3 amended to Render by WDCRequest.
AB05/03/21
NR05/03/21
LC05/03/21
Scale @ 1 : 100Proposed Elevations - Block 06 - NorthE01
Scale @ 1 : 100Proposed Elevations - Block 06 - SouthE02
Scale @ 1 : 100Proposed Elevations - Block 06 - WestE04
Scale @ 1 : 100Proposed Elevations - Block 06 - EastE03
Full coordination of external louvre positions to be undertaken upon reciept of M&E Stage 3 Design.