Fulton Electric Steam Boilers From 12 to1000 kW (1.2 to100 BHP) Built/certified in accordance to ASME Boiler and Pressure Vessel Code. All Fulton Electric Steam Boilers are UL Approved. 1.2-15 BHP are CSA Approved. A complete line of packaged boilers (15 models) for efficient, quiet and safe operation for any commercial/industrial process application.

Upload: others

Post on 20-Oct-2019

13 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Fulton Electric Steam Boilers - eesystems.ru · Fulton Electric Steam Boilers From12 to1000kW (1.2 to100 BHP) Built/certified in accordance to ASME Boiler and Pressure Vessel Code

Fulton Electric Steam BoilersFrom 12 to1000 kW (1.2 to100 BHP)

Built/certified in accordance to ASME Boiler and Pressure Vessel Code.All Fulton Electric Steam Boilers are UL Approved.1.2-15 BHP are CSA Approved.

A complete line of packaged boilers (15 models) for efficient, quiet and safe operation for anycommercial/industrial process application.

Page 2: Fulton Electric Steam Boilers - eesystems.ru · Fulton Electric Steam Boilers From12 to1000kW (1.2 to100 BHP) Built/certified in accordance to ASME Boiler and Pressure Vessel Code

Fulton manufactures acomplete line of electricsteam boilers from 12 kW to 1000 kW (1.2 to 100 BHP)up to 300 PSI for heatingand process applications.Fulton's vertical design is a fullpackaged steam boiler built to ASME specifications and applicable standardsand codes. They are very efficient because the heating elements

are totally immersed in water and thepressure vessel is fully insulated.Radiation losses are minimal. With acarefully calculated heat to steam ratio,operating pressures are achievedquickly with maximum efficiency. Electric boilers have nowasted fuel going out the stack asassociated with fossil fuels, therefore,electric boilers are environmentallyfriendly. No NOx (nitrogen oxides) are being transmitted to the atmosphere.

Stainless steel heating elementsFulton uses low watt density elements*made of stainless steel. Stainless willnot melt or anneal as easily as copperelements. The small 12 to 36 kW boilersuse horizontally mounted elements atthe bottom.

*Consult factory for specific watt densities.

Fulton Electric Steam Boilers Are Efficient,Quiet, And Safe For Your Process Needs

Page 3: Fulton Electric Steam Boilers - eesystems.ru · Fulton Electric Steam Boilers From12 to1000kW (1.2 to100 BHP) Built/certified in accordance to ASME Boiler and Pressure Vessel Code

Save valuable time and expenses in thefield by ordering complete skid mountedunits ready for power and water hook upat the sight Unit 1- 50 kW (5 BHP) 600PSIG steam boiler with dual level controls,skid-mounted, pre-piped with feed systemand tandem feedwater preheaters.This unit is used for steam injection forpharmaceutical crystallization process.

Unit 2 - 36 kW (3.6 BHP) 15 PSIG electricsteam boiler with 3 kW electric steamsuperheater skid mounted and pre- pipedwith return system and chemical feed system. Explosion proof, Class 1,Group C, D DN 1. All controls, instrumentation by Fulton including single source power connection. Thisunit is used for manufacturing/sterilizationof surgical equipment.

50 to 1000 kW elementsmount verticallyCan be serviced and periodically maintained simply by unbolting the element(s) from the flanges in the top of the boiler's "head". Expansionand contraction of the top mounted elements cause scale to flake off and drop to the bottom of the boiler.Strategically located 3" x 4"handholes allow easy inspection andperiodic clean-out maintenance.

The element(s) are easily accessible--permit quick removal for service orinspection. Heating element thermostatsare optional.

Features and advantages� Nearly 100% efficient� Quiet, clean� No NOx emissions� Ideal choice where fossil fuels are not

available or where electricity rates arefavorable

� Built to ASME Code and UL Approved� Vertical design requires minimal floor

space� Completely wired control panel box

located in front of the boiler.� Safe. Solid state relays. All wiring meets

NEC specifications.� Second (auxiliary) low water

water cut-off probe standard

1

2

Fulton can custom build completely piped and wiredskid mounted units.

Page 4: Fulton Electric Steam Boilers - eesystems.ru · Fulton Electric Steam Boilers From12 to1000kW (1.2 to100 BHP) Built/certified in accordance to ASME Boiler and Pressure Vessel Code

Component Locations of the Fulton12 to1000 kW(1.2 to 100 BHP) Steam Boilers

12 to 36 kW (1.2 to 3.6 BHP)Element(s) are horizontally mounted at thebottom of the pressure vessel. All probesare located in the top of the boiler.

50 to 200 kW (5 to 20 BHP)Elements are vertically mounted. All probes aremounted in the top of the boiler.

Note: All Fulton Electric Steam Boilers Have a second (auxiliary) low water cut-off probe.

1. Pressure Vessel Is Built ToASME Code 5 Year Warranty

2. Electrical Control Panel Box3. Electric Heating Elements4. Low Water Cut Off Probe5. Second (Auxiliary) Low

Water Cut Off Probe6. Pump "On" Probe7. Pump "Off" Probe8. Sight Glass Assembly9. Operating Pressure Control

10. High Limit Pressure Controlw/ manual reset

11. Steam Outlet12. Safety Valve13. Steam Gauge Assembly14. Steam Pressure Gauge15. High Temperature Insulation

Surrounds The Pressure Vessel16. Large (3" x 4") Easily Access

Handholes17. Feedwater Shut Off Valve18. Blowdown Valve19. Water Bottle Assembly

For 300 to 1000 kW only

Note: Al l Fulton Electric SteamBoilers have a second (auxiliary)low water cut-off probe.

3

11

1

3 4 6 7

8

11

12

13

14

16

17

18

15

29

10

5

Page 5: Fulton Electric Steam Boilers - eesystems.ru · Fulton Electric Steam Boilers From12 to1000kW (1.2 to100 BHP) Built/certified in accordance to ASME Boiler and Pressure Vessel Code

300 to 1000 kW (30 to 100 BHP)Elements are vertically mounted. These boilers have anexternally mounted water bottle assembly housing the low water cut-off probe, pump on probe and pump off probe.The second (auxiliary) low water cut off probe is mounted in the top of the boiler.

5

64

7

19

Page 6: Fulton Electric Steam Boilers - eesystems.ru · Fulton Electric Steam Boilers From12 to1000kW (1.2 to100 BHP) Built/certified in accordance to ASME Boiler and Pressure Vessel Code

(G) Boiler Only IN 20 20 20 20 20 20 17 24 24 28 32 36 44 50 63MM 508 508 508 508 508 508 432 610 610 711 813 914 1118 1270 1600

(H) Overall Depth Electric IN 30 30 30 30 30 30 35 35 35 39 46 46 56 62 83Panel to Blowdown MM 762 762 762 762 762 762 899 899 899 991 1168 1168 1442 1575 2108

(I) Electric Panel Width IN 14 14 14 14 14 14 17 17 32 32 40 52 64 64 64MM 356 356 356 356 356 356 432 432 813 813 1016 1321 1626 1626 1626

(J) Boiler Width Overall IN 33 33 33 33 33 33 35 42 42 46 52 56 64 72 91MM 838 838 838 838 838 838 889 1067 1067 1168 1321 1422 1625 1829 2311

(A) Boiler Overall IN 24 24 24 24 24 24 55 55 55 55 55 75 75 75 75MM 610 610 610 610 610 610 1397 1397 1397 1397 1397 1905 1905 1905 1905

(B) Boiler w/Piping IN 30 30 30 30 30 30 65 65 65 65 71 80 80 80 80MM 762 762 762 762 762 762 1651 1651 1651 1651 1803 2032 2032 2032 2032

(C) Feedwater Inlet IN 8 8 8 8 8 8 16 16 16 16 16 24 24 24 24MM 203 203 203 203 203 203 406 406 406 406 406 610 610 610 610

(D) Blowdown Outlet IN 4 4 4 4 4 4 6 6 6 6 6 6.5 6.5 6.5 6.5MM 102 102 102 102 102 102 152 152 152 152 152 165 165 165 165

(E) Electric Control Box IN 20.5 20.5 20.5 20.5 20.5 20.5 50 50 50 50 48 64 64 64 64MM 521 521 521 521 521 521 1270 1270 1270 1270 1219 1626 1626 1626 1626

(F) Hand Hole IN 11 11 11 11 11 11 38 38 38 38 38 55 55 55 55MM 279 279 279 279 279 279 965 965 965 965 965 1397 1397 1397 1397

Dimensions are approximate. We reserve the right to change specifications.–Indicates not available.Panel Box size may change depending on voltage.

Models FB-L 012-03612 to 36 kW (1.2 to 3.6 BHP)

Models FB-L 050-100050 kW to 1000 kW (5-100 BHP)

DimensionsModel FB-L 012 015 018 024 030 036 050 075 100 150 200 300 500 750 1000Unit Size: kW 12 15 18 24 30 36 50 75 100 150 200 300 500 750 1000

HeightHP 1.2 1.5 1.8 2.4 3.0 3.5 5.0 7.5 10 15 20 30 50 75 100

Width & Depth

Minimum Clearances(K) Horizontal IN 14 14 14 14 14 14 -- -- -- -- -- -- -- -- --

to remove elements MM 356 356 356 356 356 356 -- -- -- -- -- -- -- -- --(L) Floor to Ceiling IN -- -- -- -- -- -- 95 95 95 95 95 139 139 139 139

to remove elements MM -- -- -- -- -- -- 2413 2413 2413 2413 2413 3531 3531 3531 3531(M) Front of Boiler IN 24 24 24 24 24 24 24 32 32 32 34 34 36 36 36

MM 610 610 610 610 610 610 610 813 813 813 864 864 914 914 914 (N) Sides & Rear of Boiler IN 12 12 12 12 12 12 12 12 12 12 24 24 24 24 24

MM 305 305 305 305 305 305 305 305 305 305 610 610 610 610 610

B

F

D

C

H

M

N

N

K

E

TOP

SIDE

A

JG

I

FRONT

F

C

B

D

E

N

N

H

M

TOP

SIDE

L

A

JG

I

FRONT

Page 7: Fulton Electric Steam Boilers - eesystems.ru · Fulton Electric Steam Boilers From12 to1000kW (1.2 to100 BHP) Built/certified in accordance to ASME Boiler and Pressure Vessel Code

Probe liquid level control is standard on all units.Optional Water Level ControlsMcDonnell Miller 53-2McDonnell MIller 157 - 157M

Notes:--Indicates not available.* Indicates voltages available at special request.**Steam output ratings, at 180oF (82oC) feedwater temperature,(0 PSIG).

Standard ElectricalControl Panel Components� Low Water Relay� Water Level Relay� High Limit Pressure Control Switch w/manual reset� Operating Pressure Control Element Contactor(s) Switch� Pump Starter (1 phase)� Power Switch� Power Lamp� Element Energized Lamp � CSD-1 Low Water Relay With Manual Reset

Models FB-L 100 to FB-L 1000 include a step sequencer.

Specifications

Dimensions are approximate. We reserve the right to change specifications.Voltage applied higher than above ratings will result in higher amp draws.

012 015 018 024 030 036 050 075 100 150 200 300 500 750 1000

1 1 1 2 2 2 2 3 4 6 4 4 7 10 1441 51 61 82 102 123 171 256 341 512 683 1025 1708 2561 341610 13 15 21 26 31 43 64 86 129 172 258 430 645 86040 50 60 81 101 121 169 252 336 505 674 1011 1684 2526 336818 23 27 37 46 55 77 115 153 230 306 460 765 1148 1530

420 420 420 440 450 450 580 850 970 1225 1380 1440 1850 2150 2300191 191 191 200 204 204 263 386 440 556 623 655 839 977 10437 7 7 7 7 7 13 39 39 50 79 115 195 270 360

26 26 26 26 26 26 49 148 148 189 299 435 738 1022 1362

.75 .75 .75 .75 .75 .75 1 1.5 1.5 2 3 3 4 4 619 19 19 19 19 19 25 38 38 51 76 76 100 100 15075 .75 .75 .75 .75 .75 .75 1 1 1.25 1.5 2 3 3 319 19 19 19 19 19 19 25 25 32 38 51 76 76 76.75 .75 .75 .75 .75 .75 .75 1 1 1 1 1 1 1 1.2519 19 19 19 19 19 19 25 25 25 25 25 25 25 321 1 1 1 1 1 1 1 1 1 1.25 1.25 1.5 1.5 2

25 25 25 25 25 25 25 25 25 25 32 32 38 38 51NA NA NA NA NA NA NA NA NA NA NA .75 .75 .75 75-- -- -- -- -- -- -- -- -- -- -- 19 19 19 19

.25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .256 6 6 6 6 6 6 6 6 6 6 6 6 6 6

.75 .75 .75 .75 .75 .75 1 1 1 1.25 1.50 1.5 1.5 2 2.519 19 19 19 19 19 25 25 25 32 38 38 38 51 64.50 .50 .50 .50 .50 .50 .75 .75 .75 .75 1 1 1.25 1.5 213 13 13 13 13 13 19 19 19 19 25 25 32 38 51

(In Amps)34 42 50 67 84 100 139 208 278 416 556 832 * * *52 65 78 -- -- -- -- -- -- -- -- -- -- -- --30 35 46 60 76 92 126 188 252 378 512 756 * * *15 19 23 30 38 46 63 94 126 189 256 378 630 941 126013 16 18 24 30 36 50 76 101 150 201 301 502 756 1004

Model FB-L

Number of ElementsOutput 1000 BTU/HR

1000 KCAL/HRSteam Output** LB/HR

KG/HRApprox. Shipping Weight LB

KGWater Capacity GALLONS

LITERS

Steam Outlet 15 PSI INMM

Steam Outlet 16-300 PSI INMM

Feedwater Inlet INMM

Blowdown Outlet INMM

Water Col. Blowdown Outlet INMM

Sight Glass Blowdown Outlet INMM

Safety Valve 15 PSI INMM

Safety Valve 16-300 PSI INMM

Boiler Connection Sizes

Electrical Power Requirements208V 3 Phase230V 1 Phase230V 3 Phase460V 3Phase575V 3 Phase