fusion4 portal - honeywell · 2014. 10. 30. · microsoft windows 7 installation end user serial...

8
Fusion4 Portal Take control with Fusion4 Portal. The essential enhancement to the Fusion4 family, Portal cuts through complexity to optimize your assets and drive value to the operation. Its modular software suite brings together wide ranging remote monitoring and supervisory capabilities for all Fusion4 devices on a single, integrated dashboard. Portal lets you improve efficiency, ensure quality, and eliminate risk – all straight out of the box. Install it, and take Fusion4 to the next level. Global Experience. Locally Applied.

Upload: others

Post on 07-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Fusion4 Portal - Honeywell · 2014. 10. 30. · Microsoft Windows 7 Installation End User Serial Protocol FlexConn Ethernet Protocols FlexConn TCP/IP Languages English (US), English

Fusion4 Portal

Take control with Fusion4 Portal. The essential enhancement to the Fusion4 family, Portal cuts through

complexity to optimize your assets and drive value to the operation. Its

modular software suite brings together wide ranging remote monitoring

and supervisory capabilities for all Fusion4 devices on a single, integrated

dashboard. Portal lets you improve efficiency, ensure quality, and eliminate

risk – all straight out of the box. Install it, and take Fusion4 to the next level.

Global Experience. Locally Applied.

Page 2: Fusion4 Portal - Honeywell · 2014. 10. 30. · Microsoft Windows 7 Installation End User Serial Protocol FlexConn Ethernet Protocols FlexConn TCP/IP Languages English (US), English

Fusion4 Portal tools enrich the Fusion4 experience, building on the capabilities of the world’s most advanced family of hazardous area additive, blending and loading controllers. Connect, configure, monitor and print from the control room to deploy devices faster, smarter and more effectively.

Simple, intuitive and powerful, just like the Fusion4 family, Portal installs on a Windows PC to provide an immediate interface that continuously communicates with your Fusion4 portfolio. Providing a single view of all your devices for centralized analysis and control, Portal connects you for an optimized operation.

Expand your Horizons Fusion4 Portal suite offers users a modular solution, enabling them to choose the tools they need.

Connect Connect up to 250 streams across 50 devices, all managed from a single PC. With support for serial and Ethernet comms, Portal’s auto-discovery feature ensures devices are quickly detected and started up. Diagnostics let users view devices’ health, I/O status and other key indicators from the control room to ensure continuous, reliable service.

Configure Set up and service devices without leaving the control room. The Configure Module lets users upload, download, copy and paste device settings from the Portal dashboard.

Enabling quick upload and storage of Config files and authorization databases, Configure delivers rapid, secure commissioning and ongoing maintenance of Fusion4 devices to get set up quicker and stay online longer.

MonitorThe Monitor Module with Live Viewer lets users view any and every device operation as it happens, at the click of the mouse. Monitoring across devices in real time, it also provides an audit trail of every device transaction to radically simplify compliance and reconciliation. With alarm and comms monitoring and control, as well as a management panel for rapid identification of faults, Monitor increases safety and promotes efficiency to keep the operation moving.

PrintImprove efficiency and ensure compliance, security and traceability with the Print Module. Scan and print MID compliant transaction data, W&M approved bills of lading, and summary reports.

Fusion4 Portal’s Print module lets you schedule reports for site reconciliation, circulate summary reports for totals of each product category, reduce waiting times and bottlenecks for drivers, and slash the burden of paperwork.

2

The Essential Connection

Page 3: Fusion4 Portal - Honeywell · 2014. 10. 30. · Microsoft Windows 7 Installation End User Serial Protocol FlexConn Ethernet Protocols FlexConn TCP/IP Languages English (US), English

3

Technical Features

Set up and service devices without leaving the control room. The Configure Module lets users upload, download, copy and paste device settings from the Portal dashboard.

Print Monitor Configure OPC

SerialConnectivity • • • •Ethernet Connectivity • • • •Up to 10 Devices • • • •Up to 50 Devices • • • •Auto-Discover devices • • • •Localization (13 languages) • • • View device Diagnostic Dashboard • • • •View device System Health • • • •Construct site database • • • •Fusion4 SSC-A Support • • • Fusion4 SSC-B Support • • • Fusion4 MSC-A Support • • • Fusion4 MSC-L Support • • • 1010CB Support • •Transaction Printing • BOL Printing • BOL Archiving • BOL Customization • MID Approved • Print on Demand • Scheduled Printing • Summary Reports • Transaction Monitoring • Transaction Search • Alarm Monitoring • Alarm Management • Comms Monitoring • LIVE Viewer • Event Log • Create New Config Files • Modify Config Files • Send Config Files to Device • Retrieve Config Files to Device • Import/export Config Files to LAD • Archive Config Files • Create Authorisation Databases • Modify Authorisation Databases • Send Authorisation Databases • Retrieve Authorisation Databases • Archive Authorisation Databases • Multi Client OPC Server - 1010CB •

Page 4: Fusion4 Portal - Honeywell · 2014. 10. 30. · Microsoft Windows 7 Installation End User Serial Protocol FlexConn Ethernet Protocols FlexConn TCP/IP Languages English (US), English

Minimum Hardware Requirements:

Minimum Software Requirements:

Hardware and Software Requirements

Live Viewer View and monitor any device transaction across the site as it happens using the Monitor Module’s Live Viewer tool.

Description

Description

4

Processor Intel® Xeon® Quad Core 32-bits

Memory 4 GB RAM

Free space 1000 GB hard disk, 7200 RPM

Reader CD-ROM / DVD drive with X40 speed

Video card (Graphics card) Resolution 1080 x 800 resolution, 32-bit true colour

Keyboard Standard US keyboard

Mouse USB mouse or bus mouse

Serial port One or two (recommended) RS-232 ports + RS-485 ports

USB port Three USB ports to support USB mouse, keyboard and printer

Network interface card 10 or 100 Mbps integrated Ethernet Network Interface card

Printer The printer should have detection for: – Out-of-paper – Limited available ink – Communication failure between PC and printer The printer should support A4 or letter Colour print out is not required

Operating system Microsoft Windows 7 Professional in English (US) language 32-bit version

Hardware

Software

Page 5: Fusion4 Portal - Honeywell · 2014. 10. 30. · Microsoft Windows 7 Installation End User Serial Protocol FlexConn Ethernet Protocols FlexConn TCP/IP Languages English (US), English

Technical Specifications

5

Connect up to 250 streams across 50 devices. Auto-discovery and diagnostics delivers a quick start-up and long lasting reliability.

Approvals

MID: OIML R117-1 Edition 2007 (E) Dynamic Measuring Systems for Liquids other than water

Media

CD-ROM

Platform

PC

O/S

Microsoft Windows 7

Installation

End User

Serial Protocol

FlexConn

Ethernet Protocols

FlexConn TCP/IP

Languages

English (US), English (UK), French, German, Spanish, Dutch, Chinese (simplified), Japanese, Polish, Italian, Portuguese, Swedish, Hindi

Compatibility

Fusion4 SSC-A, Fusion4 SSC-B, MSC-A, MSC-L, 1010CB (excluding Monitor and Configure modules) Handheld Devices: Fusion4 LAD (Local Access Device)

Max Connections

50 field devices

Backward Compatibility

Upgradeable from Fusion4 Portal R120 R110 installations need to be upgraded to R120 first

Licensing

Email address required with order Hyperlink will be sent to license Portal during installation PC ‘Physical Address’ will be required

Page 6: Fusion4 Portal - Honeywell · 2014. 10. 30. · Microsoft Windows 7 Installation End User Serial Protocol FlexConn Ethernet Protocols FlexConn TCP/IP Languages English (US), English

MSG

6

Pos 1, 2, 3 Fusion4 Portal Software Suite

F 4 P

Pos 4 Number of Field Devices

S Up to 10 Devices

L Up to 50 Devices

Pos 5 Printing Module

U Transaction & BoL Printing

X Transaction & BoL Printing – EU MID Compliant (OIML R117-1)

N Not Required

Pos 6 Configuration Module

C Remote Device Configuration

N Not Required

Pos 7 Monitor Module

M Real time TRansaction & Alarm Monitoring (inc. LIVE Viewer)

N Not Required

Pos 8 OPC Interfacing (1010CB)

V Multi Client OPC Server

N Not Required

Pos 9 Remote Access

N Not currently available

F 4 P L U C M N N Sample Modelling Code

F 4 P Your Modelling Code

Page 7: Fusion4 Portal - Honeywell · 2014. 10. 30. · Microsoft Windows 7 Installation End User Serial Protocol FlexConn Ethernet Protocols FlexConn TCP/IP Languages English (US), English

Network Topology Drawings

7

TCP/IP TCP/IP

TCP/IPTCP/IP

RS-435

SSC-As

SSC-Bs

MSC-As

MSC-As

MSC-Ls

MSC-Ls

1010CBs

RS-232 /RS-435

RS-232 /RS-435

RS-232 / RS-435

Terminal Server

Ethernet Switch

RS-232 RS-232 RS-232 RS-232

RS-435

SSC-As

SSC-Bs

MSC-As MSC-Ls1010CBs

RS-232 / RS-435Converter

RS-232 / RS-435Converter

RS-232 / RS-435

RS-232 / RS-435 RS-232 / RS-435 RS-232 / RS-435

ConverterRS-232 / RS-435

Converter

Ethernet network topology with terminal server

Serial network topology

MSC-A/MSC-L

CN-152

TerminalConnectro block

Ethernet Cable*

Ethernet Cable**

* Shielded Twisted Pair Cable** T-568A or T-568B Straight-Through Ethernet Cable

Ethernet Switch

Fusion4 Portal

RJ-45Ethernet Port

RJ-45Ethernet Port

RJ-45Ethernet Port

ETH-2 (T+1)

ETH-2 (T-1)

ETH-2 (R+1)

ETH-2 (R-1)

R+

R-

T+

T-

Ethernet Connection between MSC & Fusion4 Portal

Page 8: Fusion4 Portal - Honeywell · 2014. 10. 30. · Microsoft Windows 7 Installation End User Serial Protocol FlexConn Ethernet Protocols FlexConn TCP/IP Languages English (US), English

EN-14-01-ENOctober 2014© 2014 Honeywell International Inc.

Your Terminal Operations Partner

Americas

Honeywell Enraf Americas, Inc.

2000 Northfield Ct.

Roswell, GA 30076

USA

Phone: +1 770 475 1900

Email: [email protected]

Europe, Middle East and Africa

Honeywell Enraf

Delftechpark 39

2628 XJ Delft

The Netherlands

Phone: +31 (0)15 2701 100

Email: [email protected]

Asia Pacific

Honeywell Pte Ltd.

17 Changi Business Park Central 1

Singapore 486073

Phone: +65 6355 2828

Email: [email protected]

For More InformationTo learn more about Honeywell Enraf’s Fusion4 solutions, visit www.honeywellprocess.com/fusion4 or contact your Honeywell Enraf account manager