fußschalter_7000000787_gb

2
International Headquarters Germany Bernstein AG Tieloser Weg 6 D-32457 Porta Westfalica Phone +49 571 793-0 Fax +49 571 793-555 [email protected] France Bernstein S.A.R.L. Tieloser Weg 6 D-32457 Porta Westfalica Phone +33 1 64 66 32 50 Fax +33 1 64 66 10 02 [email protected] Denmark Bernstein A/S Sindalsvej 30 DK-8240 Risskov Phone +45 7020 0522 Fax +45 7020 0177 [email protected] Netherlands Bernstein BV Tieloser Weg 6 D-32457 Porta Westfalica Phone +31 314 366088 Fax +31 314 361256 [email protected] Italy Bernstein S.r.l. Via del pero 12a/b I-24040 Levate (BG) Phone +39 035 4549037 Fax +39 035 4549647 [email protected] Great Britain Bernstein Ltd (UK) Unit 1, Westgate Park Tintagel Way Westgate Aldridge West Midlands WS9 8EX Phone +44 1922 744999 Fax +44 1922 457555 [email protected] Austria Bernstein GmbH Kurze Gasse 3 A-2544 Leobersdorf Phone +43 2256 62070-0 Fax +43 2256 62618 [email protected] China Bernstein Safe Solutions (Taicang) Co., Ltd. North 38, Dongting Road, Taicang City Development Area, Taicang 215400 Jiangsu Provice, P.R. China Phone +86 512 81608180 Fax +86 512 81608181 [email protected] Switzerland Bernstein (Schweiz) AG Steinhaldenstrasse 14 CH 8954 Geroldswil Phone +41 44 775 71 71 Fax +41 44 775 71 72 [email protected] Hungary Bernstein Kft. Fehér utca 10 1106 Budapest Phone +36 1 434 2295 Fax +36 1 434 2299 [email protected] www.bernstein.eu Other switching technology in the Bernstein range Foot switches Sure-footed Safety 700.0000.787 11.2007 · www.hartwig-at.de · Subject to modifications Foot control terminal FBT2 – Hygienic design for use in medical technology FBT1 – Hygienic design for use in medical technology – Plastic contact housing Ti2 – optimised component size retaining the standard connection techniques with type of protection IP 65 ENK – switch standardised in keeping with DIN EN 50041 – metal actuators Plastic encapsulated C2 – Smallest switch for safety applications IF – ultra-flat and flexible with type of protection IP 67 – metal actuators I88 – switch standardised in keeping with DIN EN 50047 Bi2 – two cable entries M 16 x 1.5 ENM2 – switch standardised in keeping with DIN EN 50041 Metal encapsulated GC – slim-line construction D – heavy-duty metal housing for arduous applications SN2 – three cable entries M 20 x 1.5

Upload: bernstein

Post on 25-Mar-2016

215 views

Category:

Documents


3 download

DESCRIPTION

Italy Bernstein S.r.l. Via del pero 12a/b I-24040 Levate (BG) Phone +39 035 4549037 Fax +39 035 4549647 [email protected] Netherlands Bernstein BV Tieloser Weg 6 D-32457 Porta Westfalica Phone +31 314 366088 Fax +31 314 361256 [email protected] France Bernstein S.A.R.L. Tieloser Weg 6 D-32457 Porta Westfalica Phone +33 1 64 66 32 50 Fax +33 1 64 66 10 02 [email protected] ■ C2 – Smallest switch for safety applications ■ I88 – switch standardised in keeping with DIN EN 50047

TRANSCRIPT

International HeadquartersGermanyBernstein AGTieloser Weg 6D-32457 Porta WestfalicaPhone +49 571 793-0Fax +49 571 [email protected]

FranceBernstein S.A.R.L.Tieloser Weg 6D-32457 Porta WestfalicaPhone +33 1 64 66 32 50Fax +33 1 64 66 10 [email protected]

DenmarkBernstein A/SSindalsvej 30DK-8240 RisskovPhone +45 7020 0522Fax +45 7020 [email protected]

NetherlandsBernstein BVTieloser Weg 6D-32457 Porta WestfalicaPhone +31 314 366088Fax +31 314 [email protected]

ItalyBernstein S.r.l. Via del pero 12a/bI-24040 Levate (BG)Phone +39 035 4549037Fax +39 035 [email protected]

Great BritainBernstein Ltd (UK)Unit 1, Westgate ParkTintagel Way WestgateAldridgeWest MidlandsWS9 8EXPhone +44 1922 744999Fax +44 1922 [email protected]

AustriaBernstein GmbH Kurze Gasse 3A-2544 LeobersdorfPhone +43 2256 62070-0Fax +43 2256 [email protected]

ChinaBernstein Safe Solutions (Taicang) Co., Ltd. North 38, Dongting Road, Taicang CityDevelopment Area,Taicang 215400Jiangsu Provice, P.R. ChinaPhone +86 512 81608180Fax +86 512 [email protected]

SwitzerlandBernstein (Schweiz) AGSteinhaldenstrasse 14CH 8954 GeroldswilPhone +41 44 775 71 71Fax +41 44 775 71 [email protected]

HungaryBernstein Kft.Fehér utca 101106 BudapestPhone +36 1 434 2295Fax +36 1 434 [email protected]

w w w . b e r n s t e i n . e u

Other switching technology in the Bernstein range

Foot switches

Sure-footed Safety

700.

0000

.787

11.

2007

· w

ww

.har

twig

-at.d

e · S

ubje

ct t

o m

odifi

catio

ns

Foot control terminal

■ FBT2 – Hygienic design for use in

medical technology

■ FBT1– Hygienic design for use in

medical technology– Plastic contact housing

■ Ti2– optimised component size

retaining the standardconnection techniques withtype of protection IP 65

■ ENK– switch standardised in

keeping with DIN EN 50041

– metal actuators

Plastic encapsulated

■ C2– Smallest switch for safety

applications

■ IF – ultra-flat and flexible with

type of protection IP 67– metal actuators

■ I88– switch standardised in

keeping with DIN EN 50047

■ Bi2– two cable entries

M 16 x 1.5

■ ENM2– switch standardised in

keeping with DIN EN 50041

Metal encapsulated

■ GC– slim-line construction

■ D– heavy-duty metal housing

for arduous applications

■ SN2– three cable entries

M 20 x 1.5

Tailor-made for your applications – the modular foot switch concept from Bernstein!Bernstein offers a wide range of foot switches to meet the exacting requirementsfound in industrial applications. With up to three pedals, with or without a safetycover (UN), the robust all-metal housing ensures a protection class of IP 65 as standard.The modular design gives you the possibility of defining application-dependent pedalfunctions with up to four contact combinations per pedal.

Additional contact combinations and pedal functions, combined with basic housings andswitching elements open up further control and operation variants. Complete units are alsoavailable for use in the explosion-protected area II 2G EEx d IIC T6 and the medical sector.Prefabricated foot switches are available on request.

Type Pedal 1 Pedal-independentaddition

F1 – Switching Additional Schalt- Zusatz- Schalt- Zusatz- Featureselements function einsatz funktion einsatz funktion

FG – Switching Additional Schalt- Zusatz- Schalt- Zusatz- Featureselements function

Pedal 2

F2 – Switching Additional Switching Additional Schalt- Zusatz- Featureselements function elements function einsatz funktion

Pedal 3

F3 – Switching Additional Switching Additional Switching Additional Featureselements function elements function elements function

Example

F3 – U1 SU1 Y U2 D UN

Additional functions

Latched switching YAfter the first pedal actuation, the contactsetting is maintained after the pedal isreleased. Only after a subsequent actuation is the contact reset again (bistable).

Pressure point D– Depression to the pressure point:

First pair of contacts switched– Depression beyond the pressure point:

Second pair of contacts switched (first contacts remain switched)

Features

Safety Guard (UN)Additional to protecting the pedal, the rear of the guard provides further space to accommodate additional elements:– Emergency Stop button– Contactor on DIN rail (as main power

switch)– Customer-specific fittings

Emergency Stop button (NA)Since the foot switch can be operated atsome distance from machines and plant, anEmergency Stop button conforming toVDE/DIN is directly available to the operatoron the command unit.

Pedal interlock (AT)The pedal can only be depressed after thevertical lever is disengaged with the foot. This prevents unintentional actuation of thefootswitch.

1. Rest2. Operation: Pedal pressed as far as the pressure point: the make

contacts are closed, the machine is started.3. Emergency situation: The pedal is depressed beyond the resistance

of the pressure point, the NC contact is interrupted and latched,(machine is stopped). Even when the pedal is released the contactis latched and remains in the off position. This reliably prevents anuncontrolled restart of the moving machine parts.

4. Disengagement: After the hazardous situation hasbeen remedied, manual disengagement (push -button on the side of the housing) releases thecontacts; the machine can then be initiated againby pressing the pedal as in pos. 2.

Safety foot switch with safety locking and manual disengagement

Basic types

F1: 1-pedal with / without safety cover (UN)F2: 2-pedal with / without safety cover (UN)F3: 3-pedal with / without safety cover (UN)

F1

F2

F3

Basic contact elements

U1Z 1NC/1NO slow make/break

SU1Z 1NC/1NO snap-action

U2Z 2NC/2NO slow make/break

SU2Z 2NC/2NO snap-action

SU1Z/UV1 DUN 1NC/2NO safety switching function

Safety switching function with pressure point, contact latch,manual disengagement and safety cover (see details below).

SU1Mi RG 1NC/1NO change-over with potentiometer

An integrated potentiometer allows linear control tasks to beperformed via a controller, dependant on the pedal position. A micro-switch is also activated, providing electrical isolation atthe rest or end position (facility exists for a further micro-switchto duplicate this function).