  • PV plants for research purposes in Antofagasta

    7/16

  • Soiling

    8/16

    Process by which dust deposits on a surface during exposure to the environment

    1. Due to gravity: sedimentation of the

    particles on the surface.

    2. Adhesion due to: humidity, Van der Waals

    force and/or electrostatic.

    3. Cementation with salt and other

    substances.

    4. Others: e. g. bird dropping

  • Chemical composition and particle size

    9/16

    PV plants at the coast of the Atacama desert: c-Si/a-Si tandem thin films, mc-Si and mono-Si

  • PV plants at coastal zone of Atacama Desert [ ] [ ]

    /

    22

    ==

    m

    kWm

    kWhY

    kWpkWhYGH

    PEPR

    r

    f

    STC

    POA

    STC

    DC

    Yr: Avg n of STC peak sun hours defining solar resource for PV plant

    Yf: n of hours that the PV array would need to operate at its rated power to provide the measured (DC) energy

    HPOA: 2600 kWh/m2*year Yf,mono-Si: 1760 kWh/kWp*year Yf,a-Si/c-Si: 1690 kWh/kWp*yearYf,mc-Si: 1590 kWh/kWp*year

    PRslopemono-Si: -1.7, -3.7, -1.8 %/monthPRslopea-Si/c-Si: -4.2, -4.4, -3.7 %/monthPRslopemc-Si: -1.8, -3.8, -3.1 %/month

  • Daily performance ratio and temperature

    11/16

  • Levelized Cost of Energy (LCoE)LCoE represents the generated electricity cost including the initial capital, the return of investment and variable cost

    ATC is the annualized total costs and TEP is the total energy produced.The ATC depends on total investment and variable costs () and annualized factor (:

    f=

    Where r is the discount rate and n is the lifetime of the plant in years.

    1612/Full Load Hours

  • Levelized Cost of Energy (LCoE)

    13/16

    LCoE Thin film mono-Si mc-Si

    Clean (cEURO/kWh) 14.49 13.37 15.65

    Dirty (cEURO/kWh) 15.56 14.33 16.71

    Thin film mono-Si mc-Si

    Item Value Quantity Total Value Quantity Total Value Quantity Total

    Modules 132.8 24 3187.2 231.5 18 4167 240 14 3360

    Inverters 1000 1 1000 900 1 900 900 1 900

    Dataloggers 329 0,5 164.5 329 0,5 164.5 329 1 329

    Sensors 223 1 223 223 1 223 346 1 346

    Structure 320 10 3200 320 6 1920 320 8 2560

    O&M 1O&M 2

    48.15

    48.15

    3

    12

    48.11

    192.46

    48.15

    48.15

    3

    12

    48.11

    192.46

    48.15

    48.15

    3

    12

    48.11

    192.46

    Others 209.18 1 209.18 209.18 1 209.18 209.18 1 209.18

    Total 1

    Total 2

    8031.99

    8176.34

    7631.79

    7776.14

    7752.29

    7896.64

  • PV plants at industrial environment in Atacama

    14/16

    GHI: 2540 60 kWh/m2*year

    GTI: 2850 10 kWh/m2*year

    GTI: 2640 10 kWh/m2*year

    TGI: 3500 20 kWh/m2*year

    GHI: Global Horizontal Irradiation

    GTI: Global Tilted Irradiation

    TGI: 1-axis Sun-Tracking Global Irradiation

    Yf,CdTe: 1590 80 kWh/kWp*year

    Yf,mc-Si: 1790 50 kWh/kWp*year

    Yf,mc-Si-track :2320 60 kWh/kWp*year

    PRslope,CdTe: -4.3 0.2 %/month

    PRslope,mc-Si: -4.0 0.2 %/month

    PRslope,mc-Si-track : -4.4 0.4 %/month

  • LCoE of the PV plants at industrial environment

    15/16

    Data Value Unity CdTe (fixed), 5,6 kW mc-Si (fixed), 5,2 kW mc-Si (tracking), 5,2 kW

    Module cost 0,78 US$/W $ 4.368,00 $ 4.056,00 $ 4.056,00

    Inverter cost 0,194 US$/W $ 1.086,40 $ 1.008,80 $ 1.008,80

    Balance of system, equipment 1,43 US$/W $ 8.008,00 $ 7.436,00 $ 7.436,00

    Installation labor 0,62 US$/W $ 3.472,00 $ 3.224,00 $ 3.224,00

    Installer margin and overhead 1,42 US$/W $ 7.952,00 $ 7.384,00 $ 7.384,00

    Permitting, environmental studies 0,08 US$/W $ 448,00 $ 416,00 $ 416,00

    Grid interconnection 0,3 US$/W $ 1.680,00 $ 1.560,00 $ 1.560,00

    O&M 1 (clean) 40 US$/kW-year $ 224,00 $ 208,00 $ 208,00

    TOTAL (US$) $ 27.238,40 $ 25.292,80 $ 25.292,80

    O&M 2 (dirty) 40 US$/kW-year $ 0,00 $ 0,00 $ 0,00

    TOTAL (US$) $ 27.014,40 $ 25.084,80 $ 25.084,80

    Clean (c/kWh) $ 21,86 $ 18,92 $ 14,67

    Dirty (c/kWh) $ 28,49 $ 23,79 $ 18,36

    Clean (cUSD/kWh) $ 23,78 $ 20,58 $ 15,95

    Dirty (cUSD/kWh) $ 30,98 $ 25,87 $ 19,97

  • Ongoing and future investigations

    EVA: ethylene vinyl acetate

    POE: polyolefin elastomer

    Main content of the samples

    ][mA/cm )()()( 202

    1

    dTISRqJ =

    Compound Composition

    Alpha quarz SiO2

    Albite NaAlSi3O8

    Halite NaCl

    Hematite Fe2O3

    Calcite CaCO3

  • Conclusions

    17/

    High solar radiation levels, moderate temperatures and clear sky in northern Chile

    Different environmental conditions and energy needs in Chile

    Behavior of PV technologies not well known in Chile

    Soiling and interaction of materials with the environment

    Determination of LCoE for PV plants considering actual performance, and prediction for new PV projects

    Possibility to test PV devices in Atacama (performance and material degradation, electricity costs)